Loading...
HomeMy WebLinkAboutS2016-0024 - Misc1/25"2015 4.31 PM FROM: FaX SGIITHb'ESE„P,T,i k(; INSPECTION TO: +5 (7141 501-3050 PAGE: e1j2 Ck rg,: Cunt p"ins, f� .4” ¢+, rc . r. SOUTHWEST .IitC.. �42 Cam eY 29�,Cr f l Ilii'%.f.. 4.4 PAX t11;62iVi6 FIELD DATA ON TEST SPECIMENS S)016 -00A - ASTM C31, C138, C143, C172, C173, C231, C1064 --- 1611 RulkLn CONCRETE: MORTAR: SHOTCRETE: X CORES: GUNITE: ADDRESS: 1514 RUTH LANE, NEWPORT BCH JOB #: DATE: 04/25/2016 t0B NAME: STREMICK PERMIT* S2016-0024 ISSUED BY: ARCHITECT: ENGINEER: LACHER CONTRACTOR: CAPACI ENT. SUB: DYNAMIC SHOTCRETE INC. LOCATION IN STRUCTURE: BOTTOM OF THE POOL oATE .TEST: TRACT: PHASE: LOT #: ";()N(, RETE SUPPLIER: NATIONAI RDY MX PLANT: MIX #: 7 1/2-1 ""PE OF CEMENT: V ADMIXTURE: TICKET #: 238135 St. UMP: 0.00 in. WATER ADDED: 0 gal. AIR TEMP: 0 F ICNCRETE TEMP: 0 F MIXING TIME: 0 min. TIME CAST: 11:50 P ATE CAST: 03/21/2016 RECEIVED AT LAB: 03/30/2016 >PECIMEDS MADE BY: PANCHO SPECIFIED PSI @ 28 Days: 4500 "..AB #: 67038 CLIENT: RICHARD LUiZ .� TING INFORMATION: COMPRESSIVE STRENGTH (psi.): j HEIGHT -DIAMETER RATIO: 5070 j is{.MPLE IDENTIFICATION: 746318 oATE .TEST: 0411812016 S!ZE (in.); Height X Diameter 8.000 X 4.006 AREA (!r A2): 12.60 CRUSH LOAD (Ibs): 63845 COMPRESSIVE STRENGTH (psi.): j HEIGHT -DIAMETER RATIO: 5070 v CORRECTION FACTOR: CORRECTED STRENGTH (psi.): 'BREAK TYPE; 1 C.T.M. USED: Ferney96 T,FiiRARiCS. THAT 15 NOT PEf2:A8TM C.39-. TE5T ERITE}2iA F?ER.SEC:7. ASTM C39, C174, C192, C470, C617, C42 COMPLIES: DOES NOT COMPLY: FOR INFORMATION: X 1 HIS RF. PORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUTTHE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC. `.Af,JPLES CAST BY OTHERS: '40 rf"7hese test results are from samples cast by inspectors or technicians not employed by our firm They were, eit er defivered to our laboratory or picked up by our drwer. We will accept no responsibility ter the inspection lde on the jobsite by the inspector, tur'hermore we do not fake responsibility for any iniormMion on this report other than the strengthas tested and reourted. PST 11 C39 BREAKS. I=CONE - II=CONE AND SPLIT RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING ERROL k 111=COLUMNAR - IV =SHEAR - V=SIDE FRACTURES - VI=POINTED City of Newport Beach Special Inspector Manual CITY OF NEWPORT BEACH U;> COMMUNITY DEVELOPMENT DEPAR'T'MENT BUILDING DIVISION tsnla.�Nw 100 Civic Center Drive I P.O. Box 1768 Newport Beach, CA 92658 ..... vvvvw.newDortbeachca.cxov (949) 644-3200 Project Address: 1.E14Z-A A er— PermitNumbertseiir°sa'2..4 5z016 -007A 1514 Ru+h La Inspection Type (s): caLAJZ) b C.t-� kit. Inspection Date (s): `v-21 - E(,=�, ( } Periodic QWContmuous Describe Inspection, Including Location(s): XZ -- List Tests Made: t [ Total Inspection Time Each Day: Date: Hours: List All Items Requiring Correction (Include Previously Listed Uncorrected Items): Comments: To the best of m knowledge, the work inspected was In accordance with the Building Division approved design drawings, specifications ano�analicable workmanship provisions of the U.S.C. except as noted above. 'peciat ctor si+i. e: ; ^} 9 _Date: Print Full Name: j Newport 8ea_c_h Registration No.: It 51,11 LM apeOinnReport 09(3511015 67 City of Newport Beach Special Inspector Manual r� CITY OF NEWPORT BEACH COMMUNITY DEVEIIGP'MI<1NT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive i P.O. Box 1768 Newport Beach, CA 92658 v.,vNN.newrortbeachca.aov(949)644-3200 Project Address: LA ii 61 t Permit Number: Inspection Type (s):___, Inspection Date at Based upon my personal observation and written reports of this work, it is my judgment that the inspected work was performed, to the best of my knowledge, in accordance with the approved plans, specifications, and the applicable workmanship provisions of the Uniformed Building Code, pedal ins rector 5ignaix4oe: Date: _ _ __ Print7rujll Name: Newport Beach Registration No.: SpetlallnspectlonFlnalProjectiieport 08(2512015 [93 5,2016.00A 151P1 Rufh [.n ACOUSTICAL ENGINEERING ANALYSIS 1514 Ruth Lane Newport Beach, CA 92660 For: Capaci Enterprises 11841 Kensington Road Los Alamitos, CA 90720 September 19, 2016 YANCHAR DESIGN & CONSULTING GROUP 26741 Portola Parkway, Suite 1E, Foothill Ranch, CA 926100 Tel: 949.770.6601 Fax: 949.770.6575 E-mail: info@yanchardesign.com.. Capaci Enterprisesl1514 Ruth Lane October 14, 2016 1.0 Introduction At the request of Capaci Enterprises, Yanchar Design & Consulting Group has completed field measurements and an acoustical analysis of the swimming pool equipment located at 1514 Ruth Lane, Newport Beach, CA. 2.0 Proiect Description The property is a single family residence. The pool equipment is located approximately 4 feet from the north property line and 13 feet" from the east property line. The adjacent property to the north is a two story single family residence located approximately 5 feet from the property line. The two properties are separated by a 6 foot high wood fence. The City of Newport Beach requires a sound test by an acoustical engineer is required to demonstrate that the noise level from the pump is less than 55 dBA at the property line. NBMC10.26. 025. YANCHAR DESIGN & CONSULTING GROUP 2 Capad Enterprises/1514 Ruth Lane October 14, 2016 2.0 Field Measurements Measurements were made at the site on October 14 to determine the average sound level of the pool equipment at the property line The pool equipment measured 52.7 dBA at the north property line and 49.9 dBA at the eastern property line and therefore meets the requirements of the City of Newport Beach Municipal Code. The measurement at the north property line includes the contribution of the neighbor's spa equipment which is directly opposite. A Bruel and Kjaer Model 2231 Integrating Sound Level Meter, Serial Number 1413393, and Microphone Model 4189, Serial Number 2305616 and CEL instruments Model CEL -284/2 Calibrator, Serial Number 4/09023134, were used for the measurements. Respectfully submitted, Yanchar Design & Consulting Group Carl J. Yanchar President YANCHAR DESIGN & CONSULTING GROUP 3 Capaci Enterprisesl1514 Ruth Lane October 14, 2016 PROJECT VICINITY YANCHAR DESIGN & CONSULTING GROUP 4