HomeMy WebLinkAboutF2021-0491 - Misc11oob Mucor � � pHSOF ElfR,pj "` Beginning 1883 4000 MACARTHUR 9TH & IOTH - T.I. 4000 MACARTHUR, 9TH & 10TH NEWPORT BEACH, CALIFORNIA 92660 FIRE ALARM SUBMITTAL h RECEIVED €ICT 2 t) ZVI INTERWEST CO-NSULTING GROUP A.J. Kirkwood & Associates, Inc. • 4300 North Harbor Boulevard • Fullerton, California 92835 • Tel: 714.505.1977 • Fax: 714.505.7030 4000 MACARTHUR 9TH & 10TH - T.I. 4000 MACARTHUR, 9TH & 10TH, NEWPORT BEACH, CALIFORNIA 92660 Manufacturer Model Description CSFM Listing GAMEWELL/FCI HPF-PS10 NOTIFICATION POWER SUPPLY 7315-1637:0505 (RED) PANEL,IOA - RED GAMEWELL/FCI ASD-PL3 SERIES 3 - SMOKE DETECTOR - 7272-1703:0501 PHOTOELECTRIC (LISTING FOR COMMON COOKING NUISANCE SOURCE) GAMEWELL/FCI ASD-PL3R SERIES 3 - SMOKE DETECTOR - 7272-1703:0501 PHOTOELECTRIC W/REMOTE TEST STATION CAPABILITY (USE W/SAMPLE TUBE TYPE DUCT DETECTOR HOUSING OR IN -DUCT APPLICATION) (LISTING FOR COMMON COOKING NUISANCE SOURCE) GAMEWELL/FCI B300-6 STANDARD DETECTOR BASE W/6" 7300-1653:0109 FLANGE - WHITE GAMEWELL/FCI DNR DUCT SMOKE DETECTOR 3240-1653:0209 (SAMPLING TUBE) 100-4000 FT/MIN - NON -RELAY GAMEWELL/FCI RA1OOZ REMOTE LIGHT INDICATOR 7300-1653:0212 GAMEWELL/FCI AOM-2SF SIGNAL CONTROL MODULE 7300-1703:0102 GAMEWELL/FCI AOM-2RF CONTROL RELAY MODULE 7300-1703:0102 WHEELOCK RSS-24MCC-FW CEILING MOUNT STROBE 7125-0785:0141 (WHITE) APPLIANCE - WHITE WHEELOCK E90.24MCC-FW CEILING MOUNT SPEAKER/STROBE 7125-0785:0152 (WHITE) APPLIANCE - WHITE PS SERIES ,11 5 Amp and 10 Amp, 24 Volt Power Supplies The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The PS Series is a remote power supply line from Gamewell-FCI. The HPF-PS6 is a 6 amp and the HPF-PS10 is a 10 amp, remote power supply with battery charger that maybe connected to any 12 or 24voltfire alarm control panel(FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS • Up to five (6 amp model) or seven (10 amp model) independently -configurable, power - limited output circuits for: —Class B and/or Class A NACs —Class B and/or Class A resettable or non- resettable 24V auxiliary power —door holder power • Converts from Class B to Class Awiring without losing any outputs using the ZNAC- PS converter card (sold separately) • Optimal for powering four -wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Optional addressable control, monitor, and relay modules and power -supervision relay (EOLR-1) • Configurable forANSI°Temporal 3or Temporal coded output • UL -Listed NAC synchronization using System Sensor®, Wheelock®, Gentex®, or AMSECO® appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Abilityto cascade up to four power supplies • Two (6 amp model) orthree (10 amp model) fully -isolated input/control circuits which can be programmed to any output • Two Form C normally -closed trouble relays for AC Trouble and General Trouble • 6 or 10 amp full load output, respectively, with 3 A maximum/circuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history mode for diagnostic support • Wide range end -of -line supervision value (normal: 2-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delaytimer • Completely configurable via onboard DIP switches, no extra software required • Self-contained in compact, locking cabinet constructed of heavy gauge steelwith a corrosion -resistant powder coat chip and scratch -resistant finish • Cabinet designed with ten double knockouts and a removable doorforease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire HPF-PS6/10 HPF-PS6110B • Works with any UL 864 FACP which utilizes an industry -standard reverse -polarity notification circuit • HPF-PS6/l0includethe-Honeywell Power Products lock set (PN: 17059) and key (PN: 17051) Honeywell QC,arrrewell ORDERING INFORMATION HPF-PS6: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red HPF-PS6B: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, black HPF-PS10:10.0 A, 120 VAC remote charger power supply in a Lockable, metal enclosure, red HPF-PS10B:10.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, black ZNAC-PS: Optional Class A converter card, sold separately AOM-2SF: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24VDC to power notification appliances. AOM-2RF: Addressable relay module containing two isolated sets of Form -C contacts, which operate as a DPDT switch AMM -4F: Addressable Monitor Module for one zone of normally open dry -contact initiating devices. Includes plastic cover plate and end -of -line resistor. Module may be configured for either a Class B or Class A AMM -21F: Dual Monitor Module. Same as AMM -4F except it provides two inputs for Class B wiring only AMM-21RIF: Provides two monitored inputs and two Form -C relays. Functions in Class Bwiring only MMO-6SF: Six -circuit supervised control module MMO-6RF: Six Form -C relay control module EOLR-1:12/24 VDC end -of -line relay for monitoring four -wire smoke detector power BAT -1270 -BP: Battery, 12 volt, 7.0 AH, 5 -pack (two required) BAT -12180 -BP: Battery, 12 volt,l8AH, 2 -pack BAT -12330: Battery, 12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. 17070: Alternate Honeywell Gamewell-FCI lock set, PK -625, 3/8" cam Page 2 of 3 — 9021-61096:6 • 1/25/2021 HPS SERIES TECHNICAL SPECIFICATIONS PRIMARY (AC) POWER HPF-PS6(B): 120VAC, 50/60 Hz, 5.OA maximum HPF-PS10(B):120VAC, 50/60 Hz, 6.2 A maximum Wire Size: #12-14 AWG with 600 V insulation COMMAND INPUT CIRCUIT Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 -16 V) RELAY CIRCUITS Trouble Contact Rating: 4 A at 24 VDC OUTPUT CIRCUITS • 24 VDC filtered • HPF-PS6B:T138-TI39-1A Regulated, 3A special applications; T1310-TB12 -0.3A Regulated, 3A special applications • HPF-PS10B:TB8-TBll- LSA Regulated, 3A special applications; TB12-TB14 - 0.3A Regulated, 3A special applications • 6.0A(HPF-PS66)or10.0(HPF-PS10B) maximum total continuous current for alt outputs Honeywell Gamewell-FC] 12 Clintonville Road Northford, CT06472-1610 203.484.7161 www.gamewell-fci.com SECONDARY POWER (BATTERY) CHARGING CIRCUIT • Supports lead -acid batteries only • Float -charge voltage: 27.6 VDC • Maximum current charge: 1.5A • Maximum battery capacity: 18AH(inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) PHYSICAL Dimensions: 20.0"H x 14.5W x 3.5D (cm: 50.8H x 36.83W x 8.9D) Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) STANDARDS AND CODES The HPF-PS complies with the following standards: NFPA 72: National Fire Atarm Code UL 864: Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481: Power Supplies for Fire Alarm Systems AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S24562 CSFM: 7315-1637:0505 FDNY Approved FM Approved 9021-61096 1 B 101/21 ©2021 Honeywell International Inc. Honeywell IL+J® l CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No.. [7315-1.637:0505) Page 1 of 1 .. ................ CATEGORY: 7315-- POWER UNITS LISTEE: Honeywell International Inc.One Fire -Lite Place, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models HPF-PS6, HPF-PS6B, HPF-PS6E, HPF-PS10, HPF-PS10B, and HPF-PS10E Power Supply Expander. Model ZNAC-PS Class A Converter Module. Model Variations: All HPF-PS6 Models: Maximum 6A Capacity; 5 Class B NAC's; 2 Command Inputs; Trouble and AC Loss Relays All HPF-PS10iModels: Maximum 10A Capacity; 7 Class B NAC's; 3 Command Inputs; Trouble and AC Loss Relays With Suffix "E": Nominal 24OV, 50/60 Hz AC Input Without Suffix "E": Nominal 120V, 50/60 Hz AC Input Models HPF-PS6 and HPF-PS10: Red Enclosure Models HPF-PS6B, HPF-PS6E, HPF-PS10B, and HPF-PS10E: Black Enclosure Model ZNAC-PS: Optional Class A Conversion Module Refer to listee's printed data sheet for detailed product description and operational considerations. RATING: Models HPF-PS6 and HPF-PS6B: 120V AC, 50/60 Hz, 5.OA Maximum Model HPF-PS6E: 240V AC, 50/60 Hz, 2.7A Maximum Models HPF-PS10 and HPF-PS10B: 120V AC, 50/60 Hz, 6.2A Maximum Model HPF-PS1 OE: 240V AC, 50/60 Hz, 3.5A Maximum This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Model ZNAC-PS: 24V DC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a power supply extender when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Xi 7315-0028:0513 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division �Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The InnovairFlex M Series, DNR intelligent, non -relay pho- toelectric duct smoke detector, and the DNRW watertight, non -relay photoelectric duct smoke detector feature a piv- oting housing that fits both square and rectangular foot- prints. These detectors are capable of mounting to a round or rectangular duct. The DNR/DNRW detectors can be used with the E3 Series® and 7100 Series Systems. Note: The InnovairFlexTM Series, DNR requires the Veloc- iti® Series, ASD-PL2FR Sensor and AOM-2RF, if relays are required for the fan control. The DNRW duct smoke detector, with its NEMA 4 rating, is Listed as a watertight enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water. These features allow operators to use the detector in the most extreme environments. The units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non -condensing). An improved cover design isolates the sensor head from the low -flow feature for simple maintenance. A cover tam- per feature was added to indicate a trouble signal for a removed or improperly installed sensor cover. The InnovairFlex housing provides a 3/4 -inch conduit knockout and ample space to facilitate easy wiring and mounting of the relay module. The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. WARNING:Duct smoke detectors have specific limitations. DUCT SMOKE DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building's regular Fre detection system. Refer to NFPA 72 and 90A for additional duct smoke detector 2911 application information. E3 Sedes®and Velocitl®are registered trademarks and InnovairFlex'^' Is a trademark of Honeywell International, Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Innouaidlexn" Series DNR%DNRW Duct Smoke Nousino Intelligent Non -Relay Photoelectric Duct Smoke Housinq InnovairFlex-DNRIDNRW Features • Photoelectric, integrated low -flow technology • Air velocity rating from 100 ft/min to 4,000f tmin (0.5m/s to 20.32m/sec) • Versatile mounting options: square or rectangular configuration • Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non -condensing) • Patented sampling tube installs from front or back of the detector with no tools required • New Cover tamper signal • Increased wiring space with a newly added 3/4 -inch conduit knockout • Available space within housing to accommodate the mounting of the relay module • Easily accessible code wheels on sensor head (sold separately) • Clear cover for convenient visual inspection • UL6268A Listed • Remote testing capability • Requires SLC line power only • NEMA Type 4 UL Listed for non -hazardous indoor and outdoor applications (DNRW only) • UV Resistant, UL®Listed housing and cover material (DNRW only) SIGNALING UL FM MSFM LISTED APPROVED 2.20.2 S911 3029700 Y207 7272-1703:0121 5911 GAMEWELL-FCI ° 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ®2013 by Honeywell lntema6nnal Inc. Al rights reserved. www.gamewell-fcl.com 9021-60475 Rev. E page 1 of Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlexT" DNR Intelligent Non -Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA4 Duct Smoke Detector. The detector housing shall be LIL Listed per LIL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to 4,000 ft/min (0.5 m/sec to 20.32 m/ sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS151 KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size: Rectangular Dimensions: 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.6 cm) Depth Square Dimensions: 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 Ib (0.73 kg) Environmental Rating: NEMA4 (DNRW only) Operating Temperature Range: —40 to 158°F (-200 to 70°C) Storage Temperature Range: —220 to 158°F (-300 to 70°C) Operating Humidity Range: 0% to 95% relative humidity non -condensing Air Duct Velocity: 100 to 4000 ft/min (0.5 to 20.32 m/sec) DCOIL - (if included) 17.5 - 26.4 VDC .95mA max. Electrical Ratings For information on the electrical specifications, refer to the InnovairFlex DNR Duct Smoke Detector Installation Instructions, P/N 156-3051-001R. Accessory Current Loads at 24 VDC Device Standby Trouble RA10OZ 0 mA 12 mA Max. RTS151IRTS151 KEY 0 mA 12 mA Max. Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab. (Figure 3 illustrates the front locking tab). Figure 1 Figure 2 Figure 3 i GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60475 Rev. E page 2 of 4 wvvw.gamewell-fci.com Wiring for Intelligent Non -Relay Duct Smoke Detector Figure 4 System Wiring Diagram for DNR + RA H RA (-) DNRTO RTS451IRTS451kEY/RTS151/ RTS151KEY WITH "W REMOTE TEST CAPABLE DETECTOR HEAD OPTION: COMM + OUT (CONV ONLY) + Rip RA1WZ REMOTE ALARM LED OPTION 1 PER UNIT Figure 5 DNR to RA100Z RTS451/RTS451KEY TEST COIL+ rnRuw a 5 RTS151IRTS151KEY TEST COIL- ® "' COMM+ ® 2 OUT (CONN ONLY) + -_- _ RT151/RTS151KEY JUMPER I RA+'ID0FnDN pp�� 7PERUNn Rrs+ /a Figure 6 DNR to RTS151/RTS151 Key TESTCOILOPRON 1 PER UNrr WACURRENTDRAW Important Notes: • The use of either RTS151 or RTS151 KEY requires the installation of an accessory coil, DCOIL, sold separately. For additional information, refer to the DNR or DNRW Duct Smoke Detector Installation Instructions, P/N 156-3051-001 R and the Duct Application Smoke Detectors Application Guide. • The RTS151/RTS151 KEY test coil circuit requires an external 24 VDC power supply which must be UL Listed. i GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60475 Rev. E page 3 of 4 I COMM. �,♦„ I LINE (+) COMM. I I LINE I I I I LINEM tpI UL/FM LISTED 1ST 2ND CONTROL DETECTOR DETECTOR PANEL IN LOOP IN LOOP Figure 4 System Wiring Diagram for DNR + RA H RA (-) DNRTO RTS451IRTS451kEY/RTS151/ RTS151KEY WITH "W REMOTE TEST CAPABLE DETECTOR HEAD OPTION: COMM + OUT (CONV ONLY) + Rip RA1WZ REMOTE ALARM LED OPTION 1 PER UNIT Figure 5 DNR to RA100Z RTS451/RTS451KEY TEST COIL+ rnRuw a 5 RTS151IRTS151KEY TEST COIL- ® "' COMM+ ® 2 OUT (CONN ONLY) + -_- _ RT151/RTS151KEY JUMPER I RA+'ID0FnDN pp�� 7PERUNn Rrs+ /a Figure 6 DNR to RTS151/RTS151 Key TESTCOILOPRON 1 PER UNrr WACURRENTDRAW Important Notes: • The use of either RTS151 or RTS151 KEY requires the installation of an accessory coil, DCOIL, sold separately. For additional information, refer to the DNR or DNRW Duct Smoke Detector Installation Instructions, P/N 156-3051-001 R and the Duct Application Smoke Detectors Application Guide. • The RTS151/RTS151 KEY test coil circuit requires an external 24 VDC power supply which must be UL Listed. i GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60475 Rev. E page 3 of 4 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accesso- ries are UL Listed. Figure 7 RTS151 UL 52522 Ordering Information Figure 8 RTS151 KEY UL S2522 Figure 9 RA10OZ UL S2522 Figure 10 ASD-PL2FR Part Number Description ;'11314111) Intelligent non -relay photoelectric low -flow duct smoke detector DNRW Watertight intelligent non -relay photoelectric low -flow duct smoke detector ASD-PL2FR Intelligent photoelectric smoke sensor with remote test capability in duct applications Accessories Part Number Description DCOIL Remove test coil required with RTS151IRTS151151KEY DST1 Metal sampling tube duct width up to 1 ft (0.3m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DSTS Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) DST10 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) DH4000E-1 Weatherproof enclosure ETX Metal exhaust tube duct width 1ft (0.3m) M02-04-00 Test magnet P48-21-00 End cap for metal sampling tubes RA100ZIRA100ZA Remote annunciator alarm LED RTS151 Remote test station RTS151 KEY Remote test station with key lock GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60475 Rev. E page 4 of 4 www.gamewell-fci.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM ' LISTING SERVICE `'� LISTING No. 3240-1653;0209) Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: System Sensor, Unincorporated Div of Honeywell Int'I Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models DNR) DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. 01-02-18 gt 1010 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed -®v the test results and/or other data but does not make an independent verification of any claims. This listing is not d an endorsement or recommendation of the item listed. This listing should not be used to verify correct 1 operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division ^Gamewell ® FIRE CONTROL ® INSTRUMENTS by Honeywell Description The InnovairFlex Series Duct Smoke Detector accessories add functionality to the Duct Detection System. These accessories are designed to provide quick and convenient, accessibility for visual inspections and they offer effective audible and visible notification options. All Gamewell-FCI duct detectors and accessories are UL® Listed. The following duct smoke detector accessories are available. • APA151 Piezo Annunciator • MHR Mini -Horn, Red • MHW Mini -Horn, White • RA100ZIRA100ZA Remote Annunciator • RTS151 Remote Test Station • RTS151KEY Remote Test Station with Key • RTS2 Multi -Signaling Accessory • AOS Add -On Strobe • RTS2-AOS Multi -Signaling Accessory The APA151 piezo annunciator replaces the APA451 with a new and improved look. It provides the following: • An audible alarm signal. • A red LED to indicate alarm status. • A green LED to indicate power status. It is intended for use with the Gamewell-FCI 4 -wire con- ventional duct smoke detector applications without a sys- tem control panel, to comply with NFPA 90A. The MHR and MHW SpectrAlert® Advance mini -horns fea- ture temporal or continuous tones that provide high and low volume settings. Their small footprint allows mounting to single -gang backboxes and are used for applications where a small device is desired. The RA10OZ and RA100ZA remote annunciators are designed for both conventional and intelligent applications. The red LED provides visual indication of an alarm condi- tion. The RTS151 and RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4 -wire detectors, the RTS151KEY test station features a multi- colored LED that alternates between steady green and red. For 2 -wire detectors, the LED illuminates red for alarm. InnovalrFlexTMand Sync•Circuit- are trademarks and SpectraAlert® is a registered trade- mark of Honeywell International Inc. UL®is a registered trademark of Underwriters Laboratories Inc. InnovairFleiff Series Duct Smoke Detector Accessories Notification and Test Accessories InnovairFlex-Series Accessories Features • APA151 piezo annunciator offers a new style and pro- vides enhanced audible alarm signals. • MRH and MHW SpectrAlert Advance mini -horns feature temporal and continuous tones for both high and low volume settings. • RA100Z and RA10OZA remote annunciators flexible versatility are used for both conventional and intelligent applications. • RTS151 and RTS151 KEY remote test stations are designed to test duct detectors from remote locations. • RTS2 and RTS2-AOS multi -signaling accessories are used with the InnovairFlex 4 -wire conventional duct smoke detectors. SIGNALING UL ,y FM LISTEp D APPROVED URRQ.S2522 7300-1653:0212 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 82013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60532 Rev. B page 1 of 3 Description (Continued) The RTS2 and RTS2-AOS multi -signaling accessories are designed to operate with the InnovairFlex 4 -wire conven- tional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by pressing a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add -On Strobe) is an optional accessory included with the RTS2-AOS model. Specifications, Duct Smoke Detector Accessories APA151 Piezo Annunciator Regulated 12 DC or FWR Voltage: Regulated 24 VDC Operating Voltage: 16 to 33 VDC Maximum Alarm Current: 30 mA Temperature Range: 0°C to 49°C (32°F to 120°F) Relative Humidity: 10 to 93% non -condensing Wire Gauge: 12 to 18 AWG Dimensions: 4.6" H x 2.9" W x .45' D Wire Gauge: (11.6 H x 7.3 W x 1.1 D cm) MHRIMHW SpectrAlert®Advance Mini -Horns Voltage: Regulated 12 DC or FWR Power Requirements: (Full Wave Rectified) or Test Switch: Regulated 24 VDC or FWR Operating Voltage: 8 to 33 VDC (9 to 33 VDC Alarm Response Time: with Sync•CircuitM Module) Sounder Current Draw: 22 mA RMS max. Sounder: at 8 to 17.5 Volts DC Relative Humidity: 17 mA RMS max. Wire Gauge: at 8 to 17.5 Volts FWR Dimensions: 29 mA RMS max. Wire Gauge: at 16 to 33 Volts DC Dimensions: 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range: 0°C to 49°C (32°F to 120°F) Humidity Range 10 to 93% non -condensing Nominal Sounder Frequency: 3 kHz Wire Gauge: 12 to 18 AWG Dimensions 4.6" H x 2.9" W x 0.45' D (11.6 H x 7.3 W x 1.1 D cm) RA100ZIRA100ZA Remote Annunciator Voltage Range: Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current: 12 mA Dimensions: 4.6" H x 2.8" W x 1.3" D (11.6 H x 7.1 W x 3.3 D cm) Specifications, Duct Smoke Detector Accessories (Continued) RTS151 Remote Test Station Power Requirements: Alarm LED: 2.8 to 32 VDC, RTS151 KEY Remote Test Station with Key Power Requirements: Power LED (Green): 14 to 12 mA max. Power Requirements: Total Current: 105 mA max. Test Switch: 10 VA @ 32 VDC Reset Switch: 10 VA @ 32 VDC Alarm Response Time: 40 seconds max. Temperature Range: -10°C to 60°C Sounder: (14°F to 140°F) Relative Humidity: 95% non -condensing Wire Gauge: 14 to 18 AWG Dimensions: 4.8" H x 2.90" W x 1.4" D Wire Gauge: (12.1 H x 7.3 W x 3.5 D cm) RTS151 KEY Remote Test Station with Key Power Requirements: Power LED (Green): 14 to RTS2 and RTS2-AOS Multisignaling Accessory Voltage: 35 VDC, 12 mA max. Power Requirements: Alarm LED (Red): 2.8 to 32 Standby: VDC, 12 mA max. Trouble: Total Current: 105 mA max. Alarm Response Time: 40 seconds max. Temperature Range: -10°C to 60°C Sounder: (14°F to 140°F) Relative Humidity: 95% non -condensing Wire Gauge: 14 to 18 AWG Dimensions 4.6" H x 2.75' W x 1.8" D Wire Gauge: (11.6 H x 6.9 W x 4.5 D cm) RTS2 and RTS2-AOS Multisignaling Accessory Voltage: 20 to 29 VDC Power Requirements: Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder: 85 dBA at ten feet Temperature Range: -10°C to 60°C (14-F to 140°F) Relative Humidity: 95% non -condensing Wire Gauge: 14 to 22 AWG Dimensions: 4.8" W x 5.3" H x 1.6" D (12.1 W%13.4Hx4.0Dcm) For information on the most recent product specifications and listing information, prefer to the Gamewell-FCI Web site at www.gamewell-fci.com. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60532 Rev. B page 2 of 3 www.gamewell-fci.com Accessories Gamewell-FCI provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL Listed. Fii Ordering Information Accessories Figure 2 KEY UL 52522 Figure 6 MHW UL S4011 Figure 3 UL 54011 Figure 7 MHR UL 54011 Figure 4 RTS2-AOS UL S2522 re 8 RTS2-AOS with PS24LOW robe and PS12124 LENSW lens Part um er Description Part Num er escrption ATIM 31 iezo Annunciator Remote test station wi ey lock Mini Horn, Red RTS2 u ti-signa ing accessory Miniorn, White n tro e emote annunciator alarm LED R Multi -signaling accessory RTST51 Remote est station GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60532 Rev. 8 page 3 of 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE SIJ' LISTING No. 7300-16530212) Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'I Inc.3825 Ohio Ave, St. Charles, IL has reviewed 60174 the test results and/or other data but does not make an Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 listing is not Email: lisa.brant@honeywell.com DESIGN: Models RTS151, RTS151KEY and RA100Z Duct Smoke Detector accessories. Refer to verify correct listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division r This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not J an endorsement or recommendation of the item listed. This listing should not be used to verify correct " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Honeywell I Addressable Devices QGm IIII Velociti° Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI, Velociti® Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern brightwhite color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI, ASD-PL3 photoelectric detector's re -designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi - sensor detector offers either photoelectric detection orthermal detection through dual electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory colorthat will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated bythe-IV part number after the detector model. Note: Although the E3 Series° and S3 Series panels support both the Velociti° and CLIP' protocols, the GWF-7075 panel does not supportthe CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with O L® Standard 268 7th Edition • Designed with anew profile to offer modern and improved aesthetics • Contains a built-in functional test switch activated by external magnet • Supports a low standby current Provides rotaryaddress switches (01-159) Supplies optional relay, isolator, or sounder bases (standard or low frequency) Photoelectric Detector Includes dual LEDs for Offers expanded color 3600 visibility options Ordering Information NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL" suffix indicates Black color model. NOTE: "WH" suffix indicates Bright White color model. ASD-PL3 Photoelectric smoke detector, bright white, Velociti ASD -11311-31t Photoelectric smoke detector, remote test capable, for usewith DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal sensing, bright white, Velociti ASD-PL3-IV : Photoelectric smoke detector, ivory, Velociti/ CLIP ASD-PL3R-IV: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, ivory, Velociti/CLI P ASD-PTL3-IV: Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540, Note: "IV" suffix indicates Flashscan and CLIP devices. "WH" suffix indicates bright white 8501 -WHITE: 4" Flangeless mounting base, brightwhite 8501 -WHITE -BP: 4" Flangeless mounting base bulk pack, brightwhite B501 -IV: 4" Flangeless mounting base, ivory B300-6: 6" Flanged mounting base, brightwhite B300 -6 -IV: 6" Flanged mounting base, ivory B300 -6 -BP: 6" Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, brightwhite B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, brightwhite B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH:Intelligent addressable lowfrequency sounder base, brightwhite B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224B1-WH:Isolator base, bright white 1322461-W., Isolator base, ivory DNR: Intelligent duct detector housing, non -relay DNRW: Intelligent duct detector housing, non -relay, watertight 2 Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for 8300 6" Base, ivory RAl00Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single -gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCSCOF Series detectors. (Pack of 10) CK300-BL: Black detector kit. (Pack of 10) CK300-IR-BI: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tooL Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP -4: Extension pole for XR2B.Shipped with three, 5 -foot (1.524,m) sections. Velociti°Series 3 Detectors Technical specifications SYSTEMS STANDARDS Photoelectric Intelligent Detector: The Velociti® Series 3 Photoelectric Detectors are Physical Specifications designed to complywith the following standard: Height: 2.0 inches (51 mm) installed in 8300-6 base UL Standard: UL 268 Diameter: 6.1 inches (15.49 cm) installed in 8300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 320 F to 122° F (0° C to 500 C) Photo in Duct Applications: -40 F to 1580 F (-20° C to 700 C) Photo with Thermal: 320 F to 1000 F (0° C to 380 C) Operating Humidity Range: 10% to 93% non -condensing Rate -of -Rise Detection: Responds to greater than 150F/minute or 1350F (8.3° C/minute or 570C Air Velocity Range: 0 to 4,000 ft/min (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (@ 24 VDC): 200 UA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): 2 mA Ca 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewell-FCI's Velociti° Series 3 Detectors and other products available byvisiting www.Gamewell-FCI com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com AGENCY LISTINGS AND APPROVALS These listings and approvals applyto the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL:S2332 FM:3023594 MEA FDNY: COA-219-02-E Vol. VI CSFM: 7272-1703:0501 ISO 9001 Certification 9020-0617 1 K 1 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewe[L- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series-, Velociti- and Gamewell-FCI- are registered trademarks of Honeywell International Inc. U L- is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subjectto change without notice. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE (.Jr LISTING No. 7272-1703:0501) Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR -SYSTEM TYPE -PHOTOELECTRIC LISTEE: GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: ModelsASD-PL3, ASD-PL3R) and ASD-PTL3 analog addressable, photoelectric smoke detectors for open area and duct installations. Model ASD-PTL3 has a complementary heat detector. All models are similar) except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models *13501, *1321 OLP (CSFM Listing 7300-1653:0109), B200S and B200SR (CSFM Listing 7300-1653:0213), B20OS-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300 -6 -IS bases (CSFM Listing 7300-1653:0109), *B224B1 and *B224RB (CSFM Listing 7300-1653:0126), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition, January 11, 2016. XLF: 7272-0028:0503 *Revision 12/17/19 DCC This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 INTELLIGENT BASES Standard, Relay, Isolator, Sounder, and Low Frequency Sounder Bases To meet local code and application requirements, Gamewell-FCI® offers standard 4" and 6" ,. bases, as well as specialty base designs including relay, isolator, sounder and lowfrequency j=„�,r',` sounder bases that are UL listed for low frequency operation and comply with NFPA 72, �['. requirements forsleepingspaces forthenew Gamewell-FCI Series of addressable detectors I` k as well as previous generations. The standard 4” and 6" bases offer a plug-in detector base intended for use in intelligent - systems, with screw terminals provided for power (+ and -), and remote annunciator 8300-6 Standard 6' 82005 -WH Sounder connections. Communication takes place over the power (+ and -) lines. The 4" base offers a Base (White) Base (White) compact design while the 6" base provides compatibilitywith a wider range ofjunction boxes. The specialty bases support application driven requirements. These bases employ a separate mountingplate that installsonvariousjunction box sizes toeliminate unsightlysurface- ii- mountboxes. The mounting plate enablespre -win rgofaItconnections tospeed and simplify installation. i Relay bases (B224RB-WH/8224R B -IV) provide one form -C contact relay for control of auxiliary functions, such as door closure and elevator recall. The relay can operate in two different modes (short and long delay). The activation time for the short delay is 60-100 milliseconds, while the activation time for the long delay is 6-10 seconds. A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases (B224B1-WH/B224BI-IV) allow the Signaling Line Circuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically restores when the fault is corrected. Sounder and low frequency (-LF) sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz+/-10%with a square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the most idealto wake sleeping occupants, even those with mild to severe hearing loss. FEATURES AND BENEFITS • Bases enable quick and secure detector • Standard white color with ivory and black plug-in • SEMS Screws provide easy wiring connection • UL 268 compliant • Support for 12-24AWGprovides installation flexibility • Multiple base formats meet application requirements options • Mechanical locking feature restricts removal of attached sensor head • Specialty Base Features: • Pre -wired mounting plate simplifies installation • Application driven feature sets 8501-WHITEFIangeless B501 -BL Rangeless 4" Base (White) 4' Base (Black) • Sounder bases both UL268 and UL464 compliant Honeywell The B200S sounder and LF sounder bases (B200S-WH/B200S-IV/ B200S-LF-WH/B200S-LF-IV) adopt the same address as the detector, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder— or a group of sounders —to activate. The command set from the FACP can be tailored to multiple event - driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Tempora14, or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables them to be used as a component of the general evacuation signal — along with other System Sensor AV appliances —when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. The B200SR sounder and LF sounder bases (B200SR-WH/ B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501BH Series sounder base installations. The device enables users to select one of two B501 -supported tones (ANSI Temporal or Continuous) through a jumper. PRODUCT LINE INFORMATION INTELLIGENT BASES "-IV" suffix indicates Ivory color model. "-BL" suffix indicates Black color model. "-WH" and "-WHITE" suffix indicates White color model. B21OLP: Flanged mounted base. B21OLPA: Same as B210LP: ULC listed. B21OLPBP: Bulk pack of B21OLP, contains 10. 13300-6:)White, 6" base, standard flanged low -profile mounting base 8300 -6 -BP: Bulk pack of B300-6, package contains 10 B300 -6 -IV: Ivory,6" base, standard flanged low -profile mounting base. B501 -WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed 8501 -WHITE -BP: Bulk pack of 8501 -WHITE, contains 10 8501 -BL: Black, 4" standard European flangeless mounting base 8501 -IV: Ivory color, 4" standard European flangeless mounting base B224RB-WH: White, relay base JUNCTION BOX SELECTION GUIDE B224RB-IV: Ivory, relay base B224B1-WH: White, isolator detector base B224B1-IV: Ivory isolator detector base B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone; Uses Velociti® protocol B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone; Uses Velociti° protocol B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz+/- 10%with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal or continuous tone; Intended for retrofit applications B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal or continuous tone; Intended for retrofit applications B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz+/ -10% with a square wave or its equivalent; designed to meetthe NFPA 72 sleeping space requirement; intended for retrofit applications B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base, produces a fundamental frequency of 520 Hz+/ -10% with a square wave or its equivalent; designed to meetthe NFPA 72 sleeping space requirement. Intended for retrofit applications. MOUNTING KITS AND TR300: White, replacement flange for B210LP, B300-6 base TR300-IV: Ivory, replacement flange for B21OLP, B300 -6 -IV base RA10OZ: Remote LED annunciator, 3 - 32 VDC, mounts to a U.S. single -gang electrical box; For use with B501 and 8300-6 M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Base Models Single Gang Double Gang 3.5" Oct. 4.0" Oct, 4.0"Square 4.0"Squarewith 3.0" mud ring 50 mm 60mm 70 mm 75 mm B200S,B200SR Yes Yes Yes Yes Yes Yes No No No No 8501 No No Yes No No Yes Yes Yes Yes No B300-6 Yes No Yes Yes Yes Yes No No No No B224BI,B224RB Yes Yes Yes Yes Yes Yes No No No No Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Applies to all model variants "BL",' -LF," -IT, "-WH", and "-WHITE". See Product Line Information for detailed model description. Page 2 of 3 — 9021-60540:K • 7/8/2019 INTELLIGENT BASES TECHNICAL SPECIFICATIONS ELECTRICAL For 8300-6 Series bases: • Operating voltage: 15 to 32 VDC • Standby current: 170 pA maximum For B501 Series bases: • Operating voltage: 15 to 32 VDC • Standby current: 150 pA maximum For B200 Series bases: • External supply voltage: 16 to 33 VDC(FWR) • Standby current: 500 pA maximum • Alarm current for B200S(-IV)(-WH): 35 mA maximum at high-volume setting 15 mA maximum at low-volume setting • Alarm current for B200S-LF(-IV)(-WH) High- volume setting: 70 mA maximum @ 33.0 VDC 90 mA maximum @ 24.0 VDC 140 mA maximum 0'16.0 VDC • Alarm current for B200S-LF(-IV)(-WH)Low- volume setting: 15 mA maximum @ 33.0 VDC 20 mA maximum @ 24.0 VDC 25 mA maximum @ 16.0 VDC • Alarm currentfor B200SR(-IV)(-WH): 35 mA maximum • Alarm current for B200SR-LF(-IV)(-WH): 65 mA maximum @ 33.0 VDC 90 mA maximum C 24.0 VDC 125 mA maximum 016.0 VDC SLC operating voltage: 15 to 32 VDC SLC standby current: See applicable sensor specification Sound output: Greater than 85 dBA minimum; measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) For B224BI, B224RB (-IV) (-WH) bases: • Operating voltage: 15 to 32 VDC (powered by SLC) • Standby ratings: X450 pA maximum @ 24VDC • Set time: (B224RB(-IV)(-WH) only): short delay 60-100 msec; long delay 6-10 seconds • Reset time:(B224RB/-IV/-WH only): 20 milliseconds maximum • Relay characteristics:(B224RB/-IV/-WH only): two -coil latching relay; one Form -C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9 A Ca 110 VDC, and 3.0 A @ 30 VDC PHYSICAL Note: Specifications applies to all model varia nts --BU,, "-LF", "-IW,, -WH,-WHITE. See Product Line Information for detailed model description. Diameter: • B501-WHITE:4"(10.16cm) • B300-6, B210LP:6.1" (15.49 cm) • B224BI,B224R8:6.2°(15.748cm) • B200S, B200SR: 6.875' (17.46 cm) Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT06472-1610 203.484.7161 www.gamewei[-fci.com Wire gauge: • B224BI,B224RB:14to24AWG • 6300-6, B21OLP, B501, B200S, B200SR12 to 24 AWG Temperature range: • B224BI, B224RB, B200S, B200SR:32°Fto 120°F (0°C to 49°C) • B300-6,B210LP,B501:-4oFto150°F(-200C to 66°C) Humidity range: 10% to 93% PH, non - condensing System temperature and humidity ranges: This system meets NFPA requirements for oper- ation at 0°C to 490C (320F to 1200F): and at a relative humidity (non -condensing) of 85% at 300C (86°F) per N FPA, and 93%±2%at 320C± 20C (89.6°F± 1.1°F) per ULC. However, the use- ful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended thatthis system and all peripherals be installed in an environmentwith a nominal room temperature of 150C to 270C (60°F to 800F). AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consultfactory for latest listing status. UL Listed: 5911 FM Approved CSFM: 7300-1653:0109,7300-1653:0126, 7300-1653:0213, 7300-1653:0238 9021-60540 1 K 107/19 02019 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0109) Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'I Inc.3825 Ohio Ave, St. Charles, IL by the applicant. CSFM Fire Engineering staff 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 make an independent verification of any claims. This Email: lisa.brant@honeywell.com DESIGN: Models B401, B401B, B401R, B401BR, B401BR-750, B401R-750,64026, B404B, B404BT, item listed. This listing should not be used to B406B, B501, B501B, 14506587-002, B501BH, B501BHT, B401BH, B110LP, B110RLP, 3110RLP750, B112LP, B114LP, B114LPBT, B116LP, B210LP, B501 -BL, B501 -IV, Refer to listee's data sheet, installation instructions *B501 -WHITE,!, 63004) B300 -6 -IV, 8300 -6 -IS detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, *model number, *electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. *Refer to Manufacturers Installation Instruction Manual for details. NOTE: Formerly 7300-1209:128 *Rev 04-03-18 gt Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not 3, an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Honeywell I Addressable Devices Q� Illi AMM -2F) Addressable Monitor Module General The Gamewell-FCI Velociti® Series, addressable monitor module AM M -2F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end -of -line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell-FCI addressable series fire alarm control panel. Any initiating device with normally open (NO.) dry contacts may be made addressable when connected to the AMM -2F module. The Velociti®Seriems use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM -2F module can be programmed to provide a wide variety of input functions to the Gamewell-FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, plenum detector, waterflow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possible to customize its device type to meet specificjob requirements. The initiating device circuit of the AMM -2F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Ordering Information AMM-2F:Addressable monitor module, single circuit, Style B, Class B FEATURES & BENEFITS • Compact size allows Class B, Style B, 40 Ohm line resistance Connects to any easy installation initiating circuit for each initiating normally open dry device circuit contact device AMM -2F 9 ;AMM-2FfFechnical Specifications System STANDARDS For a complete listing of all compliance approvals and Supervisory Current:.000375 amps The E3 Series Control Panel is designed to compiywith certifications, please visit: Alarm Current:.00060 amps the following standard: http://www.gamewell- OperatingTemperature: 320 to 1200 F(00 to 490 C) U L Standard: UL 8649th Edition fci.com/en-US/ documentation/Pages/ Relative Humidity: 10 to 93% (non -condensing) AGENCY LISTINGS AND APPROVALS Listings.aspx End -of -Line Resistance: 47K ohms These listings and approvals apply to the modules and Gamewell-FCIa Dimensions: 1.3"Lx 2.5"Wx0.5"D specified in this document.lnsomecases,certain are re are registered trademarks of (3.3 x 6.4 x 1.3 cm) modules or applications may not be listed bycertain Honeywell International Inc. TEMPERATURE AND HUMIDITY RANGES approval agencies, or listing may be in process. UL®is a registered trademark This system meets NFPA requirements for operation at 0 Consult factory for latest listing status. of Underwriters Laboratories — 490C/32 — 120OF and ata relative humidity 93%±2% UL: 51949 Inc. RH (noncondensing) at 320C±20C(900F±30F). FM:3023594 This document is not intended However, the useful life of the system's standby batteries MEA FDNY: 227-03-E VOL. IV to be used for installation and the electronic components may be adversely affected CSFM: 7300-1703:0102 We our product by extreme temperature ranges and humidity. Therefore, ISO 9001 Certification informurposes. ation up-eep to - product information e can date and accurate. We cannot it is recommended thatthis system and its peripherals be coverall specific applications installed in an environment with a normal room oranticipate requirements. temperature of 15 -270C/60 -800F. P All specifications are subjectto change without notice. For more information Learn more about Gamewell-FCI's AMM -2F and other products available by visiting www.Gamewell-FCI,com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 4.7161 Honeywell ll 9020-0626 1 F 1 11/17 wwwh ,7 www.hbneywelLcom ©2017 HoOeyweu mcer0aro0au0c. Honeywell Addressable Devices aGamewell Velociti Series° AOM-2RF; Addressable Output Relay Control Module General The Gamewell-FCI Velociti® Series, addressable output relay control module (AOM- 2RF) allows a Gamewell-FCI analog addressable fire alarm control panel to switch discrete relay contacts by code command. The relay provides two isolated sets of Form -C contacts which transfer simultaneously. Circuit connections to the relay contacts are not supervised by the module. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the SLC devices and certain Gamewell-FCI analog addressable fire alarm control panels. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net result produces a superior response speed up to five times greater than earlier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any Gamewell-FCI analog addressable fire alarm control panel, The module contains a panel controlled LED. The AOM-2RF is designed to mount in a 4" (10.16 cm) square junction box 21/8" (5.53 cm) deep. Ordering Information AOM-2RF: Addressable output relay control module Table 1 lists the relay contact ratings. CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION 3A 30VDC Resistive Non -Coded 2A 30VDC Resistive Coded 0.9A 11OVDC Resistive Non -Coded 0.5A 125 VAC Resistive Non -Coded 0.5A 3OVDC Inductive (L/R=5ms) Coded 1A 30VDC Inductive (L/R=2ms) Coded 0.5A 125VAC Inductive (PF=.35) Non -Coded 0.7A 75 VAC Inductive Non -Coded Tablet: Relay Contact Ratings FEATURES & BENEFITS Listed under OL Standard 864 Offers two sets of Form "C" contacts • Provides visual rotary, decimal switch addressing (01-159) • Includes bi-color LED that flashes green wheneverthe module is addressed, and lights steady red upon activation* AOM-2RF � I • Designed as a compact size to allow easy installation Note 1: Only the red LED is operative in panels that do not operate in Velociti mode *Note 2: The bi-color LED functionality is not available on the GWF-7075 panel. Velociti Series" AOM-2RF Technical Specifications SYSTEMS STANDARDS Fora complete listing of all Supervisory Current .000375 amps. The Velociti Seriese AOM-2RF is designed to com l with g Py complianons, pl approvals and cemplianceaprovals an Average Operating Current: the following standard: http://www.gamewell- 255 uA (Velociti Mode) UL Standard: UL 864 9th Edition fci.com/en-US/ 230 uA(CLIP Mode) AGENCY LISTINGS AND APPROVALS documentation/Pages/ Listings.aspx Alarm Current:.0065 amps. These listings and approvals apply to the modules Operating Temperature: 32oto 1200F(00to 49°C) specified in this document. In some cases, certain Velociti- Series and Gamewel FCI°are registered trademarks Relative Humidity: 10 to 93% relative humidity (non- modules or applications may not be listed by certain of Honeywell International Inc. condensing) approval agencies, or listing may be in process. Consult Dimensions: 41/2" H x 4"W x 11/4" factory for latest listing status. UL° is a registered trademark (11.4 x 10.2 x 3.2 cm) UL: 51913 of Underwriters Laboratories Inc. TEMPERATURE AND HUMIDITY RANGES FM: 3023594 This s stem meets NFPA requirements foroperation at y g FDNY: COA-219-02-E Vol. VI This document is not intended to be used for installation —49oC/32 — 120o o o Fand ata relative humidity 93/0±2/o - CSFM: 73001703:0102 purposes. We tryto keep our RH (noncondensing) at 32°C ± 2°C (90°F± 309. ISO 9001 Certification product information up -to - However, the useful life of the system's standby batteries date and accurate. We cannot and the electronic components may be adversely affected cover all specific applications by extreme temperature ranges and humidity. Therefore, or anticipate all requirements. it is recommended that this system and its peripherals be All specifications aresubjecttc installed in an environmentwith a normal room change without notice. temperature of 15 — 270C/60 — 80°F. For more information Learn more about Gamewell-FCI's Velociti Series®AOM-2RF and other products available by visiting www.Gamewell-FCI.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 9020-0625 1 1 104/19 N11�e1� www.honeywell.com ©2019 Honeywell International Inc. Honeywell Honeywell IN= Addressable Devices Velociti° SeriesAOM-2SF) Addressable Output Relay Supervised Control Module General The Gamewell-FCI Velociti Series addressable output supervised control module (AOM-2SF) allows a Gamewell-FCI analog addressable fire alarm control panelto switch an external power supply, such as a DC supply or audio amplifier (up to 80 VRMS) to notification appliances. The AOM-2SF notification appliance circuit can be wired either Class A (Style Z) or Class B (Style Y). It also supervises the wiring to the connected loads and reports their status to the panel as NORMAL, OPEN orSHORT CIRCUIT. The module contains a panel controlled LED. The Velociti Series use a communication protocol that substantially increases the speed of communication between the SLC devices and certain Gamewell-FCI analog addressable fire alarm control panels. These devices operate in a grouped fashion. If one ofthe devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net result is a superior response speed up to five times greater than the earlier designs. The AOM-2SF module is designed for installation in the signaling line circuit of any Gamewell-FCI analog addressable fire alarm control panel. The signaling line circuits of Gamewell-FCI analog addressable fire alarm control panels are designed to accommodate up to 159 modules per circuit. The AOM-2SF is designed to mount in a 4" (10.16 cm) squarejunction box 21/8" (5.5 cm) deep. Table 1 lists the relay contact ratings. Current Rating Maximum Voltage Load Description Application 3A 30VDC Resistive Non -Coded 2A 30 VDC Resistive Coded O.gA 110 VDC Resistive Non -Coded 0.5A 125 VAC Resistive Non -Coded 0.5A 30 VDC Inductive(L/R=5ms) Coded lA30 VDC Inductivs(L/R=2ms) Coded O.SA 125 VAC Inductive(I)F=.35) Non -Coded 0.7A 175 VAC Inductive Non -Coded Table 1: Relay Contact Ratings Ordering Information AOM-2SF: Addressable output supervised control module FEATURES & BENEFITS • Listed under UL® Standard 864 and UL2572 for Mass Notification • Designed as a compact size to allow easy installation • Includes Class A, Style Z, or Class B, Style Y notification appliance circuit • Accommodates audio amplifiers up to 80 VRMs • FM Listed as suitable for a releasing device service AOM-2SF Includes a bi-color LED that flashes green wheneverthe moduleis addressed, and lights steady red upon activation* *Note 1: Only the red LED is operative in panels that do not operate in Velociti mode *Note 2: The bi-color LED functionality, is not available on the GWF-7075 panel. Velociti° Series AOM-2SF Technical Specifications SYSTEM STANDARDS For a complete listing of all compliance approvals and Supervisory Current: 0.00375 amps The Velociti Series AOM-2SF are designed to comptywith certifications, please visit: Alarm Current:.0065 amps the following standard: http://www.gamewell- OperatingTemperature:32°to 1200 F(0°to 490 C) UL Standards: UL 8649th Edition fci.com/en-US/ Relative Humidity: 10 to 93% relative humidity AGENCY LISTINGS AND APPROVALS documentation/Pages/ Listings.aspx (non -condensing) These listings and approvals o the modules Velociti and Gamewell-FCI® Dimensions: 4 1/2" H x4" W x 11/4" D specified in this document. In somesome cases, certain are registered trademarks of (11.4 H x 10.2 W x 3.2 D cm) modules or applications may not be listed by certain Honeywell nternational Inc. TEMPERATURE AND HUMIDITY RANGES approval agencies, or listing may be in process. UCre are9istered hademarkof This system meets N FPA requi rements for operation at COnsUlt factory for latest llstln status. y 9 Underwriters Laboratories Inc. This document is not intended —490C/32-120°F a nd at a relative hu midity 93%±2% UL: S1949 to be used for installation RH(noncondensing)at320C±20C(90eF±309. FM:3023594 purposes. We tryto keep our However, the useful life of the system's standby batteries MEA FDNY: 227-03-E Vol. IV product information up -to - and the electronic components may be adversely affectedM: CSF-1703: 7300 0102 date and accurate. We cannot cover aLLspecific applications by extreme temperature ranges and humidity. Therefore, ISO 9001 Certification or anticipate all requirements. it is recommended thatthis system and its peripherals be Ali specifications aresubjectto installed in an environment with a normal room change without notice. temperature of 15 — 270C/60 — 80°F. For more information Learn more about Gari I's Velocitix Series AOM-2SF and other products available by visiting www.Ga mewell-FC1,com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 9020-0627 1 1 108/18 Honeywell www.honeywell com ©2018 Honeywell International Inc. LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: APPROVAL: NOTE: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1703:0102) 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models AMM -4, *AMM -4F, AMM -2 and *AMM-2F)monitor modules and Models AOM, AOM -2, AOM -2R, *AOM-2RF) AOM -2S and!*AOM-2SF)control modules. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, electrical rating and UL label. Listed as accessories for use with separately listed compatible control units. System Sensor Model SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules FORMERLY: 7300-0694:178 7300-1653:0103 12-4-07 Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not aO an endorsement or recommendation of the item listed. This listing should not be used to verify correct a" operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Series RSS and RSSP Strobes and Strobe Plates Series RSS Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi -candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models includethe patented MCC multi -candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models maybe synchronized using the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi -Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. SL M APPROVED 55391 151-92-E 7125-0785:141 Series RSS Series RSSWP Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPA/UFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi -Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi -Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage • Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datatsheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT W W W.000PERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • `Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP - Wall Mount Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC Models 1575cd 15cd 30cd75cd 1 110cd 135cd I 185cd 15cd I 30cd I 75cd I 95cd 115cd 177cd ULmax* 0.090 0.060 10.092 0.165 0.220 0.300 0.420 1 0.065 0.105 0.189 0.249 1 0.300 1 0.420 RSS/RSSP RSS/RSSP 24VDC Wall Mount Models RMS current ratings are per UL average RMS method. UL max current 121575W rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at UL max* 0.255 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Table 2: Audibies/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET -1010/1080, E70, ET70 Chimes CH70 SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE 0 NAC SYNC 0 CIRCUIT 01 OUT t IN RSSRSS RSS FACP MINUSI 0. AUDIBLE MINUS 2 i t IN2 RSS RSS RES NAC NAC .oUT2 CIRCUIT RETURN Wiring Diagrams 11 RSS/RSSP APPLIANCE FROM + + TO NEXT PRECEDING- APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 Sync Strobe NAC Cir. 0+ RSS RSS F A DSM #2 Strobe NAC Cir. Sync � RSS RSS C DSM #3 P Sync Strobe NAC Cir. + RSS RSS DSM Interconnecting wiring shown. Maximum of twenty (20) /PLATE ASSEMBLY & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT APPLIANCE =DING ± ± OR EOLR �NCE,SYNC LE, POWER .Y OR WEIR + -JT STROBE AUDIBLE STROBE/PLATE ASSEMBLY WITH WHEELOCK POWER SUPPLIES AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY Series PS Power Supplies FROM + HS RSS + TO NEXr PRECEDING APPLWNCEOR F14 APPLIANCE - FACP 4 -cuss - OR EOLR FROM +--lf--- --- +TONE PRECEDING STROBE. SYNC - — "I"'f 1 f — — — — 6TROBE OR — EOLR MODULE, POWER P - SUPPLY OR FACE HS RSS X eves PS Power Supplie P+1 0 + - B,D,E,F,G,H,J,N,O,R,X STROBE APPLIANCE X 4 For detail using DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83177 for DSM. For wiring information on the power supplies refer to Wheelock Power Supplies. Specifications and Ordering Information SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH WHEELOCK POWER SUPPLIES Wall Mount Series PS Power Supplies Non- Sync y HS RSS 24 VDC OUTPUTS EOLR F14 Color WHITE Mounting Options*** 4 -cuss A R. MEA OR HIS RSS C 2 -CLASS RSS-24MCW-FR .A. P - X HS RSS X eves PS Power Supplie Model Order Code Wall Mount Ceiling Mount Non- Sync y Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Options*** Square or Round Agency Approvals UL MEA CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-AR**** 9773 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X I - I X 15 (75 on Axis) X - X - I B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FW 7788 X - X 15 (75 on Axis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15 (75 on Axis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15 (75 on Axis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCC-FW,' 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSS-24MCCH-FWj 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSS-24MCWH-FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSSWP-2475W-FR** 9013 X _ X 180@ 77*F 75@ -31-F X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSSWP-2475W-FW** 3034 X - X 180@ 77-F 75@ -31-F X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X - RSSP-121575W-FR 7798 X - X 15 (75 on Axis) - X X - D,E,Z Square X - X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 15 (75 on Axis) - - X - D,E,Z Square XX X X X RSSP-24MCWH-FR 9482 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X - All models sync with Wheelock DSM or Wheelock Power Supplies. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. **** "A" stands for Agent Lettering. tvrcnrrecrs ana The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi -Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non -synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single - gang, double -gang, 4 -inch square, 1 00m European type backboxes, orthe SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi -Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. LFEM 1� WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3YEAR WARRANTY SO410 RSS/RSSP 07/11 Cooper Notification is Wheelock° MEMO $AFEPATH° CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. ;7125-0785:0141) Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Thomas Conover (941) 487-2336 Email: thomaslconover@eaton.com DESIGN: Synchronized or non -synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-#NCR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW{ RSS-24MCC, RSS-24MCCR, RSSP-24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS-24MCCHR,(RSSP-24MCgH), *ZRS-MCC, *ZRS-MCW, *ZRS-MCCH and *ZRS-MCWH. _- Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 = 1 6-33VDC/FWR Candela 15=5cd,1575=15/75cd on axis,30=30cd,75=75cd,110=110cd(Wall) RSS-24MCW,RSSP-24MCW,*ZRS-MC W:Selectablel5cd,30cd,75cd or110cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC,*ZRS-MCC:Selectable 15cd,30cd,75cd and 95cd RSS-24MCW H,RSS-24MCWHR, RSSP-24MCWH,*ZRS-MCW H:Selectable 135cd,185cd RSS-24MCCH, RSS-24MCCHR,RSSP-24MCCH,*ZRS-MCCH:Selectable 115cd,177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models *Rev. 12-13-2006jw itThis listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7125-0785:0141 Page 2 of 2 SM -12/24, SMX-12/24, DSM -12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. *Rev. 12-13-2006 jw Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed =`t the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: ,July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Wheelock E70 & E90 Speakers & Speaker Strobes 6:T•N Powering Business Worldwide Description The Wheelock E70 Wall and E90 Ceiling Speakers and Speaker Strobes are designed for high efficiency sound output for indoor applications. The E product line features intelligible communications with crisp, clear voice messages and tone signaling, ideal for mass notification, and voice evacuation. Providing a sleek aesthetic appearance, the Wheelock Series E High Speaker Strobes feature dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 2 watts. The low profile design incorporates a speaker mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic two (2) screw grille cover. For visible signaling to meet the hearing impaired, the E Speaker Strobe models incorporate the Low Current draw RSS Strobes. Strobe options for wall mount models include 1575 or Wheelock patented MCW multi -candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models are available in Wheelock patented MCC multi -candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The strobe portion of all E Speaker Strobes may be synchronized when used in conjunction with the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy The E Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing -Impaired) and Standard 1480 (Speaker Appliances). All inputs employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. Color options for the E Speakers and Speaker Strobes are red and white. Technical Data TD450024EN Effective April 2018 Features • Intelligible Communications • Efficient design for high intelligibility at minimum wattage across a frequency range of 400 to 4000 HZ • Field Selectable Settings • Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi -Candela models) • Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (Multi -candela models) Field Selectable Taps • 1/8 watt up to 2 watts • 25 or 70 VRMS operation Easy -to -Install • Low profile design incorporates speaker mounting plate for faster and easier installation Built- in level adjustment feature and an aesthetic two (2) screw grille cover. Quick installation with IN/OUT screw terminals using #12 to #18 AWG wires 4" square backbox prevents wire damage • E70 No extension ring required • E90 Optional extender (E90 Ext) is available for mounting to 4" square backboxes Strobe Synchronization Components • Meet synchronizing standards with Wheelock's DSM Sync Modules, Power Supplies or SAFEPATH products Compliance • UL 1971, UL 1480 California State Fire Marshal (CSFM) ADA/NFPA/ANSI/OSHA FCC Part 15, ICES Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton.com/ massnotification for current installation instructions. EATON .eatmcom Wheelock E70 & E90 Speakers & Speaker Strobes Drawings Figure 1. E70 (top) and E90 (bottom) Speakers - Front & Side Views 2.eB oa ].58 0 OO 0000000000 0 00000000 000 0 0 00000000 0.. O 00 00 0000000 0 1. 0 D ..000000000000 00 0000-0000000000 0000 00000000000 0 0 000000000000000 00000000000000 0000000000 OO a Voeeo° e°8 4o oe^gS8° evo°sa8 °088�U. eegg °aa e °.o ooeao .o. ovea�a�o s8 0 0 0 Figure 1. E70 (top) and E90 (bottom) Speakers - Front & Side Views 2.eB oa ].58 0 04 0000 11011* O nn n. --zsz % .2 N 6. a Voeeo° e°8 Figure 2. E70 (top( and E90 (bottom) Speaker Strobes - Front & Side Views General Notes • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range" Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. Wheelock E70 & E90 Speakers & Speaker Strobes Table 1. Maximum RMS Current Regulated Voltage Model Range VDC E70 16.0-33.0 E90 16.0-33.0 UL Max Current O 24MCWH/24MCCH 110 '115 135 0.220 0.300 0.065 0.105 0.189 0.249 0.300 0.420 Table 2. UL Listed Models and Ratings Strobe Cornish, ela Red White Lettering Wall Ceiling Sync w/ DSM or Options Wheelock Power Supplies Speakers UL Reverberant dBA at 10 Feet D E70 -R 9965 7/3 watts P, (I E70 -W 9866 Model CaJ 1/4 watts 1/2 wens 1 walla 2 watts E70 Speaker 72 75 78 81 83 E90 Speaker 72 75 78 81 82 E70 Speaker Strobe 71 75 78 81 83 E90 Speaker Strobe 74 77 80 82 85 Table 3. Specification & Ordering Information Technical Data TD450024EN Effective April 2018 Madel Order p Strobe Cornish, ela Red White Lettering Wall Ceiling Sync w/ DSM or Options Wheelock Power Supplies Speakers E70 -R 9965 X No Lettering X P, (I E70 -W 9866 X No Lettering X P, Q E90 -R 9875 X No Lettering X P, Q E90 -W 9876 X No Lettering X P, Q Speaker Strobes E70-24MCW-FR E70-24MCW-FW E70-24MCW-NW E70-24MCW-ALR E70-24MCW-ALW E70-24MCWH-FR E70-24MCWH-FW E70-24MCWH-ALW E70-24MCC-ALR E70-24MCC-ALW E70-24MCC-NW E90-24MCC-FR E90-24MCC-FW) E90-24MCC-NW E90-24MCC-ALW E90-24MCC-ALR E90-24MCCH-FR 'E90-24MCCH-FW) E90-24MCCH-ALR E90-24MCCH-ALW E90-24MCCH-NW 0183 0184 9748 4123 4124 0185 0186 4456 4308 5838 1000 0191 0192 3181 4189 4309 0194 0193 0980 2975 2974 X X X X X X X X X X X X X X X X X X 1:1 X X FIRE X FIRE X No Lettering X ALERT X ALERT X FIRE X FIRE X ALERT X ALERT ALERT No Lettering FIRE FIRE No Lettering ALERT ALERT FIRE FIRE ALERT ALERT No Lettering X X X X X X X X X X X X X P, Q P, Q P, Q P, Q P, Q P,Q P, Q P, Q P, Q P, Q P, Cl P, Q P, Q P,Q P, Cl P, Q P, Q P, Q P, Q P, Q P,Q 0 BMS current ratings are per UL maximum BMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. b dBA ratings are based on testing under UL Standard 1480. c 1/8 watt tap is for private mode only. Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. EATON w xatonxom 3 Technical Data TD450024EN Effective April 2018 Table 4. Specifications Physical Wheelock E70 & E90 Speakers & Speaker Strobes Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 ULflammability rating. Weight E70 Speaker: 1.7 us (0.77 kg); E70 Speaker Strobe 1.8 lbs (0.82kg); E90 Speaker: 1.5 lbs (0.68 kg); E90 Speaker Strobe 1.6 Iles (0.73 kg) Lens GE Lexan 943A Dimensions E70 Speaker: 5.13" W x 5.13" H x 0.43"D; E70 Speaker Strobe: 5.13" W x 5.13" H x 2.56"D; E90 Speaker: 7.27" Diameter x 0.43" D; E90 Speaker Strobe: 7.327 Diameter x 2.68" 0 Operating Temperature Indoor: 33.8°F to 120.2°F (il to 49°C) and maximum humidity of 93% Mounting & Wire Connections Mounting (indoor only) 4"square backbox with extension ring prevents wire damage; SBB for surface mount of E70 Wire Connections #12 through#18 AWG Power & General Operating voltage 25/70 VRMS Strobe Output Rating UL 1971 Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, Power Supplies or SAFEPATH products, using Wheelock patented sync protocol Frequencv Ranae 400 Hz to 4000 Hz Architects and Engineers Specifications The speaker appliances shall be Wheelock Series E70 or E90 Speakers and Speaker Strobe appliances or approved equals. The speakers shall be UL Listed under UL 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL 1971 for Emergency Devices for the Hearing -Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class A. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range. The strobe shall be of low current design. Where Multi -Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL 1971 at 15/30/75/11 Ocd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Lang Branch, NJ 07740 www.eaton.com/massnotification © 2018 Eaton All Right. Reserved E'M7.N PPuibtedtionSA No.TD450024EN PowedngBusiness worldwide April 2018 When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock DSM sync modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non -synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series E speakers and strobe speakers shall be red or white. All speaker and speaker strobe appliances shall be backward compatible. UL 1971, UL 1480, CSFM, FCC. Eaton is a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7125-0785:0152) Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste, 105, Sarasota, FL 34243 Contact: Thomas Conover (941) 487-2336 Email: thomaslconover@eaton.com DESIGN: Models *ET70-241575W, ET70-24MCW, ET70-24MCC, ET70-24MCWH, ET70-24MCCH, *ET80-241575W, ET80-24MCW, ET80-24MCWH, *ET90-241575W, ET90-24MCW, ET90-24MCC, ET90-24MCWH, ET90-24MCCH, E70-24MCW, E70-24MCC, E70-24MCWH, E70-24MCCH, E90-24MCW, E90-24MCC) E90-24MCWH and E90_-24MCC4;multi-candela speaker/strobes. Models E60 -R, E60 -W, E60-24MCC-FW, E60-24MCCH-FR, E60-24MCCH-FW, E60EXT-R and E60 -EXT -W multi -candela speaker/strobes. May be followed by suffixes to designate lens lettering and plate color. *Lens color may be Clear, Red (R), Blue (B), Green (G), or Amber (A). EXT is an extender ring that mounts behind the speaker. Intended for indoor use only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC, 25/70 VRMS Flash rate: 60 flashes/min Candela: MCW=15cd,30cd,75cd or 1 10c MCC=15cd,30cd,75cd or 95cd MCWH = 135cd,185cd MCCH = 115cd,177cd *1575 = 15 cd/75cd on axis INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Models followed by W or WH are wall mounts; C or CH are ceiling mounts. All models are for indoor use. MARKING: Listee's name, model number, electrical and candela rating, and UL label. APPROVAL: Listed as strobe speakers suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM -12/24 or DSM -12/24 synchronized control modules (CSFM Listing No. 7300-0785:132) must be used. Refer to manufacturer's Installation Manual for details. NOTE: These units do not generate a temporal pattern signal. If the distinctive three -pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. *Rev. 07-30-10 fm itThis listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division