Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F2022-0168 - Misc
02/14/2022 Interface 3750SohaufeleAve. Su�ite�g2OO ®® 1 ax: �949V505 �Y www.}}nterfacesysxom Project Name: BUCK MASON SUITE 1135 Project Address: System Type: Project#: 1135 NEWPORTBEACH CENTER DR FIRE ALARM 11451 NEWPORT BEACH, CA. 92660 *** PROJECT SUBMITTAL DOCUMENTS *** Section 1 - License & U.L. Certification Section 2 - Equipment Specification Datasheets DATA SHEET# PART# DESCRIPTION CSFM# 1. FL-PS6 Fire Lite 6amp Power Supply 7315-0075:0510 PS -1270 Powersonic 12vdc 7.OAH Battery N/A 2. SD500-ANM Silent Knight Addressable Notification Module 7165-0559:0135 3. SD500-ARM Silent Knight Addressable Relay Module 7300.0559:0132 4. SD500-AIM Silent Knight Addressable Monitor Module 7300-0559:0132 5. SD505-PHOTO SK Addressable Smoke Detector 7272-0559:0178 6. HSWC Cooper Horn/strobe, Ceiling Mount, Multi -CD, White 7125-0785:0168 7. STWC Cooper Strobe, Ceiling Mount, Multi -CD, White 7125-0785:0168 8. 1504-AQN5 Door Holder, Wall Mounted w/ Long Catch Plate 3550.1501:0137 9. RTS151KEY System Sensor Remote Test Switch with Key 7300-1653:0212 Section 3 - CSFM Listing Sheets Enclosed in this Booklet are the data sheets describing the equipment Interface Security Systems Is proposing to furnish. Revision Note: Light italic text indicates items previously submitted and approved. Dark Text indicates revisions to the original submittal and new submittal items. M. SETTLEMOIR Interface Security Systems Designer Interface 00 LICENSE & UL CERTIFICATIONS Muref3 01. Section I 10141141 CERTIFICATE OF COMPLIANCE COVER PAGE Listed Service From: EARTH CITY, MO Alarm Service Company: Applicant Subscriber No: 750680-001 Service Center Number: 1 Service Center: INTERFACE SECURITY SYSTEMS L L C INTERFACE SECURITY SYSTEMS L L C 3773 CORPORATE CENTRE DR 3773 CORPORATE CENTRE DR EARTH CITY MO 63045-1130 EARTH CITY MO 63045-1130 08 -JAN -2021 ACTIVE LISTINGS CCN File No. Vol. No. UUJS 55402 1 UUFX S3521 1 CPVX S26545 1 Service Center: INTERFACE SECURITY SYSTEMS L L C INTERFACE SECURITY SYSTEMS L L C 3773 CORPORATE CENTRE DR 3773 CORPORATE CENTRE DR EARTH CITY MO 63045-1130 EARTH CITY MO 63045-1130 08 -JAN -2021 uApplicant ID No: 750680-001 Service Center No 1 Expires: 31 -MAR -2022 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: EARTH CITY, MO Alarm Service Company: (750680-001) Service Center: (750680-001) INTERFACE SECURITY SYSTEMS L L C INTERFACE SECURITY SYSTEMS L L C 3773 CORPORATE CENTRE DR 3773 CORPORATE CENTRE DR EARTH CITY MO 63045-1130 EARTH CITY MO 63045-1130 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category BP6545 -1 CPVX [Burglar Alarm Systems] Central Station S3521 -1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective S5402-1 UUJS Signaling Services) Central Station [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Local, Auxiliary, Remote Station and Proprietary ***THIS CERTIFICATE EXPIRES ON 31 -MAR -2022 ** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" UL LLC CERTIFICATE OF COMPLIANCE COVER PAGE Listed Service From: LONG BEACH, CA (LONG BEACH) Alarm Service Company: Applicant Subscriber No: 743925-001 Service Center Number: 7 Contract Number is: LLC20115357 ACTIVE LISTINGS CCN File No. Vol. No. UUFX S7279 1 Service Center: INTERFACE SECURITY SYSTEMS L L C, DBA INTERFACE SECURITY SYSTEMS L L C, DBA INTERFACE SYSTEMS INTERFACE SYSTEMS 3750 SCHAUFELE AVE STE 200 3750 SCHAUFELE AVE STE 200 LONG BEACH CA 90808-1779 LONG BEACH CA 90808-1779 08 -JAN -2021 UApplicant ID No: 743925-001 Service Center No 7 Expires: 31 -MAR -2022 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: LONG BEACH, CA (LONG BEACH) Alarm Service Company: (743925-001) INTERFACE SECURITY SYSTEMS L L C, DBA INTERFACE SYSTEMS 3750 SCHAUFELE AVE STE 200 LONG BEACH CA 90808-1779 Service Center: (743925-001) INTERFACE SECURITY SYSTEMS L L C, DBA INTERFACE SYSTEMS 3750 SCHAUFELE AVE STE 200 LONG BEACH CA 90808-1779 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listina Category S7279-1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31 -MAR -2022 *** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" CONTRACTORS 1:3 c= STATE LICENSE BOARD •w»^•° ^ • ACTIVE LICENSE .......•...469046 —,LLC a..„.....•. INTERFACE SECURITY SYSTEMS LLC DBA INTERFACE SYSTEMS WIN_•...+ten Ct0 a 08/31/2023 www.esib.ca.gov um EQUIPMENT SPECIFICATION DATASHEETS:W=--mmm-j AV Section FL-PS6(C) & FL-PSIO(C) 6 Amp and 10 Amp, 24 Volt Remote Power Supplies The PS Series is a remote power supply line from Fire -Lite Alarms and is a direct replacement for the FCPS-24FS6/8 Series. The FL- PS6(C) is a 6 amp and the FL-PS10(C) is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notifica- tion appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. Features • Up to five (6 amp model) or seven (10 amp model) inde- pendently -configurable, power -limited output circuits for: — Class B and/or Class A NACs — Class B and/or Class A resettable or non-resettable 24V auxil- iary power — door holder power • Converts from Class B to Class A wiring without losing any out- puts using the ZNAC-PS converter card (sold separately) • Optimal for powering four -wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Configurable for ANSI® Temporal 3 or Temporal 4 coded output • UL -Listed NAC synchronization using System Sensor®, Whee- lock®, Gentex®, or AMSECOO appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) or three (10 amp model) fully -isolated input/ control circuits which can be programmed to any output • Two Form C normally -closed trouble relays for AC Trouble and General Trouble, Ground Fault relay available on Canadian mod- els only • 6 or 10 amp full load output, respectively, with 3 A maximum/cir- cuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history modes for diagnostic support • Wide range end -of -line supervision value (normal: 2K -27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra soft- ware required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion -resistant powder coat chip and scratch -resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries DF -61093:C • D-60 ® FIY@•LITeALaf ms by Honeywell Power Supplies/Accessories Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire Works with any UL 864 FACP which utilizes an industry -standard reverse -polarity notification circuit Optional devices include addressable control, monitor, and relay modules and power -supervision relay (EOLR-1) Standards and Codes The FL -PS Series comply with the following standards: NFPA 72 National Fire Alarm Code • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode), 10th Edition • UL 1481 Power Supplies for Fire Alarm Systems • IBC 2009 (when using SEISKIT-MULTI-1) • CBC 2007 (when using SEISKIT-MULTI-1) Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S2424 ULC Listed: S2424 (FL-PS6/1 OC) CSFM Approved: 7315-0075:0510 FDNY Approved FM Approved OF -61093:C • 3/10/2021 — Page 1 of 2 SYSTEM SPECIFICATIONS Primary (AC) Power: Ordering Information FL-PS6(C): 120 VAC, 50/60 Hz, 5.OA maximum FL-PS6) 6.0 A, 120 VAC remote charger power supply in a lock- FL-PS10(C): 120VAC, 50/60 Hz, 6.2 A maximum able, metal enclosure Wire Size: #12-14 AWG with 600 V insulation Command Input Circuit: • Trigger Input Voltage: 9 to 32 VDC • Trigger Current: 2.0 n (16 - 32 V); Per Input: 1.0 n (9 - 16V) Trouble Contact Rating: 4 A at 24 VDC Output Circuits: • 24 VDC filtered, regulated • FL-PS6: TB8-TB9 — to Regulated, 3A special applications; TB10-TB12 — 0.3A Regulated, 3A special applications • FL-PS10: TB8-TB11 — 1.5A Regulated, 3A special applications; TB12-TB14 — 0.3A Regulated, 3A special applications • 6.0 A (FL-PS6) or 10.0 A (FL-PS10) maximum total continuous current for all outputs Secondary Power (Battery) Charging Circuit: • Supports lead -acid batteries only • Float -charge voltage: 27.6 VDC • Maximum current charge: 1.5 A • Maximum battery capacity: 18 AH (inside cabinet) • Maximum battery charging rapacity: 33 AH (external cabinet) Physical: • Dimensions: 20.0"H x 14.5'W x 3.5"D (cm: 50.8H x 36.83W x 8.9D) • Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two IS AH batteries is 39 pounds (17.7 kg) FL-PS6C: Same as above, ULC -listed model FL -PSI 0: 10.0 A, 120 VAC remote charger power supply in a lock- able, metal enclosure FL -PSI OC: Same as above, ULC -listed model ZNAC-PS: Optional Class A output converter module CMF -300: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notifica- tion appliances. CRF -300: Addressable relay module containing two isolated sets of Form -C contacts, which operate as a DPDT switch MMF-300: Addressable Monitor Module for one zone of normally open dry -contact initiating devices. Includes plastic cover plate and end -of -line resistor. Module may be configured for either a Class B or Class A IDC. MDF -300: Dual Monitor Module. Same as MMF-300 except it pro- vides two inputs for Class B wiring only CDRM-300: Provides two monitored inputs and two Form -C relays. Functions in Class B wiring only. CMF -300.6: Six -circuit supervised control module CRF -300-6: Six Form -C relay control module EOLR-1: 12/24 VDC end -of -line relay for monitoring four -wire smoke detector power BAT -1270 -BP: Battery, 12 volt, 7.0 AH, 5 -pack (two required). BAT -12180 -BP: Battery, 12 volt, 1 SAH, 2 -pack BAT -12330: Battery, 12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the FL -PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. Fire -Lite® Alarms and System Sensor® are registered trademarks of Honeywell International, Inc. Wheelock® is a registered trademark of Cooper Technologies Company. Gentex® is a registered trademark of Gentex Corporation. AMSEC00 is a registered trademark of Potter Electric Signal Company, LLC. ANSI® is a registered trademark of the American National Standards Institute, Inc. 02020 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Page 2 of 2 — DF -61093:C • 3/10/2021 This document is not intended to be used for Installation purposes. iso{CIRRI w We try to keep our product information up-to-date and accurate. all We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. MpMBINT S fAANIPoflIEISt IIISAIITY SYSTEMS For more information, contact Fire -Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Country of Ongin: USA www.firelite.com Page 2 of 2 — DF -61093:C • 3/10/2021 PS -1270 12V6.5AN@10-hr. Rechargeable Sealed Lead Acid Battery PS - General Purpose Series Ft: Quick disconnect tabs, 0.187'x 0.032'- Mate with AMP. INC. FAST014 187'sedee Ill Quick disconnect tabs, 0.250' x 0.032' - Mate with AMP. INC FASTON "250" series 1-2.5 DR t ! N 1 + -ry 3.4 r �m Torque - Not Applicable Torque - Not Applicable CORPORATE HEADQUARTERS T T L' 5.95(151) W: 2.56 (65) T H Power -Sonic Corporation H: 3.70 (94) ® W HT: 3.86 (98) ® L Tolerances are+/ -0.04 in. (+/-lmm) and+/-a.0a in. F: +1 (619) 6613650 F: +44 (0)1268 560902 height E: salesEMEA@power-soniacom Shelf Life (% of nominal capacity at 68°F (20"C) dimensions. At ect i All datatice. 1 Month (ochangewxhoN notice. t changeV CORPORATE HEADQUARTERS HT (USA AND INTERNATIONAL EXCLUDING VITA) T H Power -Sonic Corporation 3 Buckingham Square, 7550 Panasonic Way, San Diego, Hurricane Way, Wickford, California 92154 POWER Bill MODEL Po5p�2"lO Ft e� L T: +44 (0)1260 560686 F: +1 (619) 6613650 CORPORATE HEADQUARTERS POWER -SONIC EUROPE LIMITED (USA AND INTERNATIONAL EXCLUDING VITA) (EMEA- EUROPE, MIDDLE EAST AND AFRICA) Power -Sonic Corporation 3 Buckingham Square, 7550 Panasonic Way, San Diego, Hurricane Way, Wickford, California 92154 Essex SS71 BVQ T: +1 (619) 6612020 T: +44 (0)1260 560686 F: +1 (619) 6613650 F: +44 (0)1268 560902 E: customer-service@power-soniacom E: salesEMEA@power-soniacom To., -Wo rdof@Imr opoaAon allays Fdtt'.do laleelOrlon of our orohrcal M ... e,,aapubllshedrnwrwebsM. a 2l 1-1e3c. O.'Falion. AlVgMa r.rlrveE.Allvatlemeekea�eNeplopwtroflM1eh�eapmrveownen. Alldalaaubecllachangewahomnoliu. el • Absorbent Glass Mat (AGM) technology for superior performance • Valve regulated, maintenance free spill proof construction • Power/volume ratio yielding excellent energy density • Rugged vibration and impact resistant ABS case and cover • Gas recombination technology • 5 year design life APPROVALS • Approved for transport by air. D.O.T., I.A.T-A., F.A.A. and C.A.B. certified • U.L. recognized • IS09001:2015 -Quality management systems Nominal Voltage 12 volts (6 cells) Nominal Capacity 20 -hr. (350mA to 10.50 volts) 7.00 AH 10 -hr. (650mA1010.50Volts) 6.50 AH 5 -hr. (1.2A to 10.20 volts) 6.00 AH 1 -hr. (4.5A to 9.00 Vohs) 4.50 AH Approximate Weight 4.80 lbs. (2.1 B kg) Imandal Reaistance(approx.) 23.0 milliohms Most Short -Duration Discharge Current (10 See.) 70.0 amperes Shelf Life (% of nominal capacity at 68°F (20"C) 1 Month 97% 3 Month 91% 6 Month 83% operating Temperature Range Charge Discharge Case Power Sonic Chargers 5-F (-15'C) to 122'F (50'C) -4'F (-20l to 140°F (60°C) ABS Plastic PSC-1280OA-C PSC -121000 -PC PS -1270 ;2Vs:s�l@ ohr: Rechargeable Sealed Lead Acid Battery PS — General Purpose Series SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE 100 . Gwg'ugamc ne'%daunles taa%W®peury80, Isrequirea.' CCM1eyingi lorebhep reroverry60, lull rapaary.'n 40JW�4 a U 0 0 2 4 6 8 70 12 14 76 18 20 Standing Period (Months) CHARGING Cycle Applications: Apply constant voltage charge at 2.35v/c - 2.45v/c (14.1 - 14.7v for 12v Monobloc) at 20°C. Initial charging current should be set at less than 0.25C Amps. Switch to float charge to avoid overcharging. "Float" or "Stand -By" Service: Apply constant voltage charge of 2.25v/c - 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging Voltage for both Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifications. APPLICATIONS • General purpose • Medical • Emergency lighting • Fire and security CORPORATE HEADQUARTERS (USA AND INTERNATIONAL IXCLUDINU Bill Power -Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 IT: +1(619)6612020 F: -1(619)6613650 E: customer-service@power-sonic.com POWER -SONIC EUROPE LIMITED RMEA- EUROPE, MIDDLE EAST AND AFRICAI 3 Buckingham Square, Hurricane Way, Wickford, Essex ss11 e T- +44(On 2 F: +44(0)12 E: salesEME To insure safe and efflosl dMalan all nafrmmelalesl anon a OUT hn[cau ® tole. Powe,.., Como non. All,igms reerced. Ali redInil ne,he pmpe,ry orl Mal .... A n wl,had nonce.,Aod 100 80 60 40 20 Ambient Temperature 20-C (68'F) �_ Fla at Ch arging Voltage I� 2.25-2.30 V/Cell 0 L 0 CHARGERS 2 3 4 5 Years Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities. Please refer to our website for more information on our switch mode and transformer type chargers. Please contact our technical department for advice if you have difficulty in locating a suitable charger. FURTHER INFORMATION Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc. Honeywell ®SrLINT' KNIGHT SD500-ANM Addressable Notification Module The SD500-ANM is an Addressable Notification Module for use with the Honeywell Silent Knight fire alarm control panel. The SD500-ANM provides a single class A or B circuit that is controlled by the I ntelliKnight's Signaling Line Circuit. Power for the circuit is provided to the SD500-ANM module from a separate powersupply, making it easy to power remote devices. The notification circuit, remote power and communication to the SD500-ANM are supervised by the FACP. Each notification module is programmed with a unique SLC loop address. When an event that controls the notification module occurs, the notification switches its built-in relayfeeding power from the auxiliary power input to the notification appliance. The SD500-ANM can produce at[ 16 of the notification patterns available on the fire alarm control panel. F1= \TJF'ES K ESE N F F I T S • Class A(Style Z) or • Polling LED visible • MEAappioved Class B(Style Y) through cover plate .Adds up to 127 Notification Circuit • UL listed, complies independent output • Flexible programming, with NFPA 72 circuits on each SLC choose the cadence • CFSM approved loop pattern (twelve standard & four user -defined) SDS00-ANM • Supervised auxiliary power input • Completely supervised Uses the RS -485 SBUS to interface with the panel SD500-ANM Technical Specifications FRONT VIEW jIl 4-7/8" xaxpwnx 4-7/8" PHYSICAL: Mounting: 4° square SD500-ANM DIMENSIONS ENVIRONMENTAL Operating Temperature: 32°F to 120-F (0°C to 49°C) Humidity:0 to 93% relative humidity (non condensing) ELECTRICAL: Operating Voltage: 24VDC SLC Current:.55mA Aux. Power Current: Alarm: 56ni Standby: 6mA Notification Appliance Current: 2A max. ORDERING INFORMATION SD500-ANM: Addressable notification module AGENCY LISTINGS AND APPROVALS UL Listed, complies with NFPA 72 CSFM MFA 429-92-E, Vol 9 FM approved For more information Learn more about Honeywell Silent Knightand other products by visiting www.silentknight.com Fora complete listing of all compliance approvals and For Technical Support, COMPATIBILITY call 800-446-6444. The SD500-ANM is compatible with the following Honeywell Silent Knight FACPs: 6820: Addressable fire alarm control panel with up to 1,110 addressable points 6820EVS: Addressable fire alarm control panel with an emergency mass notification system, up to 1,110 addressable points 6808: Addressable fire alarm control panel with up to 198 addressable points 6700: Addressable fire alarm control panel with up to 100 addressable points 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency communication systems 5808: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 2 Clintonville ent a Roadight Honeywell 12 Clintonville Road Northford, CT 06472 3502201 F 111117 SELENT' 800-328-0103 3 2017 Honeywen International Inc. ®KNIGHT certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. C Silent Knight^and Honeywell'' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for [j l installation purposes_ We try to keep our product information up -to H 1/4" date and accurate. We cannot cover all specific �----^ applications oranticipate all requirements. Alt specifications are subject to change without notice. For Technical Support, COMPATIBILITY call 800-446-6444. The SD500-ANM is compatible with the following Honeywell Silent Knight FACPs: 6820: Addressable fire alarm control panel with up to 1,110 addressable points 6820EVS: Addressable fire alarm control panel with an emergency mass notification system, up to 1,110 addressable points 6808: Addressable fire alarm control panel with up to 198 addressable points 6700: Addressable fire alarm control panel with up to 100 addressable points 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency communication systems 5808: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 2 Clintonville ent a Roadight Honeywell 12 Clintonville Road Northford, CT 06472 3502201 F 111117 SELENT' 800-328-0103 3 2017 Honeywen International Inc. ®KNIGHT Honeywell ®SILENT' WGFff SD500-ARM Addressable Relay Module The SD500-ARM is an addressable device that adds two Form C contacts to the Farenhyt addressable system. The contacts are rated at 2.0 amps FRONT VIEW 30 VDC or.6 amp @ 12C VAC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. COMPATIBILITY The SD500-ARM is compatible with the following Honeywell Silent Knight FACPs: 6820: Addressable fire alarm control pa net with up to 1,110 addressable points 6820EVS: Addressable fire alarm control panel with an emergency mass notification system, up to 1,110 addressable points 6808: Addressable fire alarm control panel with up to 198 addressable points 6700: Addressable fire alarm control panel with up to 100 addressable points 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panelwith an emergency communication systems 5808: Addressable fire alarm control panel 5700: Addressable fire alarm control panel FEATURE`S & 8ENEFITS • TWO sets of Form C • Relay prograrnming Is contacts. (Double completely flexible— pull/Double Throw can be mapped to relays) zone conditions. • Contacts are rated at • potting LED visible 2Vr 30 VDC or.6A;,� through cover plate. 120 VAC. • UL listed, complies • Up to 127 relays can with NFPA 72. be used on each SLC loop. SD500-ARM SD500-ARM Technica[ Specifications 4 -square electrical box /l SD500-ARM circuit board l ; IP and mounting plate (assembled at the factory) I 0 CALI17 19 I/ Honeywell 13 Ft screws through notches on mounting plate. Tighten screws to secure to box. TYPICAL MOUNTING FOR SDS00-ARM SPECIFICATIONS ORDERING INFORMATION PHYSICAL: SD5I)O-ARM; Addressable relay module '- -- Mounting: 4' square AGENCY LISTINGS AND APPROVALS ENVIRONMENTAL ILL Listed Operating Temperature: 32-F to 120°F(0°C to CSFM 49°C) MEA 429-92-E, Vol9 Humidity:O to 93% relative humidity( non FM approved condensing) ELECTRICAL: Standby Current:.55 mA Alarm Current:.55 mA Contact Rating: Form C 2A @ 30VDC or6ACo 120VAC For more information Learn more about Honeywell Silent Knight and other products by visiting www,s i ten tkn i g ht.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 3502181 G 111/17 2017 Honeywell International Inc. Fora complete listing of all compliance approvals and certifications, please visit www.siLentkn ight.com, Microsoft, Windows. and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation, Silent Knight' and Honeywell' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up -to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, cah800-446-6444. Honeywell ®SILENT' IOVIc;fff w 3SILENT 0 KNIGHT by Honeywell SD500-AIM & SD500-MIM Addressable Input Modules IntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD600-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4" -square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The SD500-AIM and SD500-MIM are addressable input modules for use with the Intelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4" -square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features • Single contact monitor • SD500-AIM supports Class A (Style D) or Class B (Style B) contact monitor wiring • SD500-MIM support for Class B (Style B) contact monitor wiring • DIP switch programmable for fast installation • Up to 2500 ft wiring distance from either input module to contact • Use up to 14 gauge wire • UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 502 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9" W x 4.9" H x 1 " D 112.4Wx 12.4 H x 2.5 D cm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5' W x 2.5' H x 0.7" D (3.8 W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) • Attractive ivory cover plate with the SD500-AIM Humidity: • Small and lightweight size allows for 10% — 93% non -condensing flexible mounting options with the SD500-MIM SD500-AIM 9�3 • SD500-MIM Approvals NFPA 71 & NFPA 72 UL 864 CSFM 7300-0559:132 MEA 429-92-E Vol. IX FM Approved for use with the 5820XL PN# 350231 Rev. G © 2016 Honeywell International Inc SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKiright FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4" -square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate ,moi i rl - Compatible FACPs Ordering Information 5820XL SD500-AIMllnput Module 5820XL-EVS Addressable input module with ivory 5808 cover plate. 5700 SD500-MIM Input Module Addressable mini input module. NI Pm rUmWd setl Pave, Lnuleg �T. wnUd b gmonlo" �=- U.ImM ( -? 7628- Compatible 6]d ®SILENT This document is not intended to be used for installation purposes. We try to keep our product KNIGHT information up-to-date and accurate. We cannot cover all specific applications or anticipate all il requirements. All specifications are subject to change without notice. For more information, contact by Honeywell Silent Knight 12 Clintonville Road, Northford, CT 06472-1610.Phone: (800) 328-0103 Fax: (763) 493-6475 For Technical Support, Please call 800-446-6444.. www.slientknight.com pang mo_mbreG 6A EM EOL Compatible FACPs Ordering Information 5820XL SD500-AIMllnput Module 5820XL-EVS Addressable input module with ivory 5808 cover plate. 5700 SD500-MIM Input Module Addressable mini input module. NI Pm rUmWd setl Pave, Lnuleg �T. wnUd b gmonlo" �=- U.ImM ( -? 7628- Compatible 6]d ®SILENT This document is not intended to be used for installation purposes. We try to keep our product KNIGHT information up-to-date and accurate. We cannot cover all specific applications or anticipate all il requirements. All specifications are subject to change without notice. For more information, contact by Honeywell Silent Knight 12 Clintonville Road, Northford, CT 06472-1610.Phone: (800) 328-0103 Fax: (763) 493-6475 For Technical Support, Please call 800-446-6444.. www.slientknight.com 0 SILENT KNIGHT by Honeywell Addressable Photoelectric Smoke Detector Detect smoldering fires quickly and get help fast with photoelectric smo IntelliKnight® ke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-PHOTO photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-PHOTO compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-PHOTO offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal -resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-PHOTO Analog / Addressable Photoelectric Type Smoke Detector The SD505-PHOTO is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505'-PHOTO'units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features • Low profile, 2 inches, including base • Simple and reliable addressing without mechanical switches • Automatic compensation for sensor contamination • Built-in fire test feature • Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. • Vandal -resistance locking features • Field cleanable • UL listed, meets NFPA 72 Ch 7 requirements • CSFM approved • MEA approved • FM Approved Specifications Operating Voltage: 24-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA SD505-PHOTO Smoke Detector Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% non - condensing Air Velocity: 0 - 300 FPM Compatible Bases: SD505-6AB (Sold Separately) SD505-61B SD505-6RB SD505-6SB P/N 350225 Rev G © 2015 Honeywell International Inc. Model SD505-PHOTO Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-PHOTO. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-HEAT Heat Detector. Base shall be the appropriate twist -lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal -resistant, security lacking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-PHOTO shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter= 5-15/16" Diameter = 3-15/16" iE Height = 2 inches, including base Model SD505-6AB Detector Base Model SD505-PHOTO Detector Head (front view) (front view) ® SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: by Honeywell (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com Exceder LED3 Horn Strobes, Strobes & Horns m ETON Powering Business Worldwide Description The Wheelock Exceder'n' LED3 horns, horn strobes, and strobes by Eaton feature an advanced power saving LED technology in a sleek, modern, enclosure that will provide high energy efficiency and an aesthetically pleasing low profile design that will blend with the building's interior decor. Compliant and Compatible Eaton's Exceder LED3 strobes meet the 20 millisecond light pulse duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement, xenon and LED devices can now be in the same field of view. With the Exceder LED3 line, Eaton now offers a full range of products with low and high candela settings ideal for both retrofits and new construction. High Efficiency, LED Technology Eaton's high energy efficient technology leads the industry in lowest current draw for the most popular candela settings, which reduces overall power consumption and costs in fire alarm and emergency communication systems. As the first notification appliances in the industry to utilize LED as the light source, this breakthrough and patented optical design, resulting in best -in -class efficiency, enables material and system cost savings, allowing for a greater number of appliances on the notification appliance circuit and fewer power supplies. All strobe models feature a wide -range of candela settings (15, 30, 75, 95cd) on a single appliance. Low Profile Design and Feature Set With the industry's smallest footprint, the Exceder LED3 horns, horn strobes, and strobes are aesthetically pleasing to building owners as the low profile design does not detract from the interior decor. Installers will benefit from its comprehensive feature list, including lowest current draw, no tools needed for setting changes, and convenient mounting options for both new and retrofit construction. These products are suitable for indoor ceiling -mount applications. The LSTC3 Strobe, LHSC3 Horn/Strobe, and the LHNC3 Horn are for 24V operation. LHNC3 is also suitable for 12V applications. Approvals and Synchronization The Exceder LED3 notification appliances are listed under UL Standards 1971 and 464 and under CAN/ULC-S525 and CAN/ULC- S526. The appliances are Restriction of Hazardous Substances (ROHS) compliant and contain no mercury or other hazardous substances. In addition, the Wheelock Exceder LED3 product line has been UL/ ULC listed as compatible with all Fire Alarm Control Panels (PACP) and accessories that have been determined to be compatible with Wheelock RSS strobe -based products including the RSS, CH, E, EH, ET, ST, ITS, MT, S8, SA, STH and Z Series. The listing also includes the ability to install the Exceder LED3 strobes in the same notification zone and field of view with any Wheelock RSS strobe models. Technical Data TD45011BEN Effective July 2017 Features • Energy Efficient • Patented LED provides industry's lowest current draw • Fewer power supplies required, smaller wire gauge, reduced wire runs • Restriction of Hazardous Substances (ROHS) • Low -Profile Design • One of the smallest, most compact ceiling designs • Sleek, modern aesthetics with no visible mounting screws • Special Lettering Available • 4 Field Selectable Settings in 1 Device Select 15, 30, 75, 95 cd • 2 Audible Settings • Select 90 or 95 dB • Select temporal or steady horn output • Easy -to -Install Finger slide switches—No tools needed for setting changes IN/OUT screw terminals using #12 to #18 AWG wires • Mounting Options include Exceder LSPKBB-C backboxes, 4" square, 1 112 or 2 1/8"deep and 4" Octagonal, i r'h" or 2 1/8"deep • Strobe Synchronization Components Ability to mix xenon and LED strobes in the same field of view Meet synchronizing standards with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products • Compliance NFPA 72 2016 - 20 ms flash duration requirements • UL 1971, UL 464, ULC -S525, ULC -5526 California State Fire Marshal (CSFM) RoHS FCC Part 15, ICES Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton.com/ massnotification for current installation instructions. General Notes Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range" Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL 1971, 2 EATONw catorxom Drawings Exceder LED3 Horn Strobes, Strobes & Horns Figure 1. Ceiling Horn Strobe - Top View Figure 2. Ceiling Horn Strobe - Side View Exceder LED3 Horn Strobes, Strobes & Horns Table 1. Strobe Ratings U W LC Max Current a LED3 Strobes 24VDC Regulated Voltage Model Range VDC 1s 30 75 95 LSTC3 16.0-33.0 0.040 0.053 0.155 0.240 Table 3. Code 3 Horn Strobe Ratings Technical Data TD450118EN Effective July 2017 Table 2. Horn Ratings Exceder LED Home Regulated Voltage Model Renge VOC 95 do 90 d9 LHNC3 8.0-17.5 0A24 0.018 LHNC3 16.0-33.0 0.030 0.022 U W LC Max Current a at Anechoic 95 di UL/i Max Current a at Anechoic 90 daA Modal Voltage b 15 30 75 95 Venal 15 30 75 95 LHSC3 16.0-33.0 0.044 0.061 0.169 0.267 16.0-33.0 0.042 0.060 0.168 0.264 Table 1. Table 4. Specification St Ordering Information or Model Sal Carmelo Red Ham Strobes LHSRC3 15/30/75/95 `LHSWC3) 15/30175/95 Strobes LSTHC3. LSTWC3,1 LSTHC3-AL I STWC3-AI FIRE FIRE 15/30/75/95 X FIRE 15/3005/95 X FIRE 15/30/75/95 X ALERT 15/30/75/95 X ALERT Hams LHNRC3 X No Lettering X LHNWC3 X No Lettering X Accessories LSPKBB-CR Exceder LED Backbox X LSPKBB-CW Exceder LED Backbox X Table 5. Specifications Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating Weiaht 0.55 lbs. Diode (LED) in a rugged Lexan Ions Dimensions 6.26" Diameter x 1.5" D Operating Temperature Indoor: 32°Fto 122°F (0'C to 511 and maximum humidity of 93% Mourning & Wire Connections Mounting (indoor only) Coiling -mount applications. The LHNC3 can also be used for wall -mount applications. Exceder LSPKBB-C backboxes or to 4" square, 11/2 or 21/8"and Octagonal,1 %z" or 21/8"deep Wire Connections #12 through#18 AWG Power & General Operating voltage 12 VOCNFWR: 8-17.5 VDCNFWR, 24VDCNFWR: 16 - 33 VDCNFWR (12 VDC LHNC3 models only) Strobe Output Rating UL 1971, ULC S526: Selectable 15, 30, 75, 95 candela output Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes and horns can be synchronized with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH prod- ucts, using Wheelock patented sync protocol Temporal Audible Pattern Selectable Continuous or Code 3 Ham tone: The Code 3 temporal pattern (1/2 second on, 1/2 second off, 1/2 second on, 1/2 second off, 1/2 second on, 1-1/2 off and repeat) is specified by ANSI and NFPA 72 for standard emergency evacuation signaling. a RMS current ratings are per UL maximum RMS method. UL max current rating Is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For auricles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. b Regulated Voltage Range-VDC EATON vry uutnncam Technical Data TD4501IBEN Effective July 2017 Architects and Engineers Specifications The LED notification appliances shall be Wheelock® ExcederUd LED3 LHSC3 Audible Strobe appliances, LSTC3 Visual Strobe appliances and LHNC3 Audible appliances for ceiling -mount applications with a low -profile design or approved equals. The LHSC3 and LSTC3 Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service, The LHSC3 and LHNC3 Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). The Series shall be Restriction of Hazardous Substances (RoHS) compliant and contain no mercury or other hazardous substances. All Series shall meet the requirements of FCC Part 15 and ICES -003. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 16 to 33 VDC. The LHSC3 Audible Strobe and LSTC3 Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Light Emitting Diode (LED) as the light source with a rugged Lexan® lens. The appliances shall be of low current design. The LED strobe flash duration shall be 20 ms. Where multi -candela appliances are specified, the strobe intensity shall have 4 field selectable settings at 15, 30, 75, 95 candela for ceiling -mount applications. The selector switch for selecting the candela shall be tamper resistant. Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of two (2) field selectable settings for EPA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. Exceder LED3 Horn Strobes, Strobes & Horns The LHSC3 Audible Strobe, LSTC3 Strobe and LHNC3 mounting options shall include LED Ceiling backboxes, 4" square, 1 1/2 or 2 1/8"deep and 4" Octagonal, 1 Yz" or 2 1/8"deep, Two wire appliance wiring shall be capable of directly connecting to the mounting base. Removal of an appliance shall result in a Supervision fault condition by the Fire Alarm Control Panel (FACP). All notification appliances shall be backwards compatible. The LHSC3, LHNC3 and LSTC3 ceiling models shall have a low profile measuring 6.26" Diameter with 1.5"D. When synchronization is required, the appliance shall be compatible with Wheelocli DSM Sync Modules, PS Power Supplies, SAFEPATH products or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non -synchronized flash - rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® patented sync protocol. UL 1971, UL 464 ULC -5525-16, ULC -5526-16, CSFM, FCC, ICES, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dos Eaton standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland. CH 44122 United States Eston.com Eaton Life safety & mass notification solutions 273 arancli Ave. Long Branch, NJ 07740 Eaton. comiass not If kation ® 2017 Eaton Rig ts Ressived E -7•N Endedf in S T0450119EN Powering Business Worldwide July 2017 Eaton is a registered trademark. All .,her trademarks are property of their respective owners. I 1504 Series > Ulecast metalconsirucilon The 1504 Series electromagnetic door holder is a high quality device > Powder epoxy aluminum finish for use with single doors. The electromagnet assembly is designed for flush wall mounting and operates on 24V AC/DC or 120V AC. The electromagnet is designed to be flush wall mounted inside a ' standard single gang outlet box (not supplied). Field wiring conned > UL Listed tions are made to the electromagnet inside the electrical box. The catch plate assembly may be mounted to the door either by > FM Approved through -bolting or by using the concealed surface mounting plates. r Designed to be used on self-closing, swinging doors to automati- > 25 Ib (11.3kg) minimum holding cally isolate an area when activated by Fre alarm, smoke detection force or sprinkler systems. Can also be operated by manual control — wherever the instant closing of doors is necessitated for safety or for convenience. Hospitals—for stairwell doors, room doors, long corridors, schools — exit door (closes all doors at once by pushbutton control); offices (instant privacy by pushing a button on your desk), nursing homes and public buildings. The 1504 Series door holder is an auxiliary device designed for wall mount applications that require holding single doors. ACCESSORIES Cat No. Description 1500-1 1.5" Extension Kit (see pg. .1.2-67) -1500-2 2"Extension .Kit (see pg. 12-67) 1500-7 7" Extension Kit (see pg. 12-67) 1500.12 12" Extension Kit (see pg. 12-67) C52595-5 Catch plate kit -short CS2598-5 Catch plate kit - long 90 Fieldstone Court I Cheshire, CT 06410 Ph: 203.699.33001 Fx: 203.699.3108 Edwards Signaling © Copyright 2004 Edwards www.edwards- signaIs.cam & Security Systems® mna (21 mm) '1504A06) *60Hz 4 5/8' (117mm) 2 3/4' �...I (70mm) A `i 24V AC' 24V DC 120V AC 2 5/8' (67mm)---� 0.015 0.015 0.015 Edwards Signaling 90 Fieldstone Court 1 Cheshire, 06410 Sin Copyright 2004 Edwards 7 g Ph: 203.699.3300 ( Fx: 203.6999 .3108 & Security Systems® www. edwariis-s1gnaIs.eom SYSTEM NSO Duct Smoke Detector Accessories Expand the versatility of the InnovairFlex" line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA151 MHR MHW Piezo Annunciator Mini -Horn, Red Mini -Horn, White Remote Annunciator Remote Test Station Remote Test Station with Key Multi -Signaling Accessory Add -On Strobe Multi -Signaling Accessory Agency Listings �L FM LISTED"""°"`° Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4 -wire conventional duct smoke detector applications without a system control panel, to comply with N FPA 90A. The MHR and MHW SpectrAlert Advance mini -horns feature temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single -gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RT5151 and RT5151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4 -wire detectors, the RTS151 KEY test station features a multi -colored LED that alternates between steady green and red. For 2 -wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi -signaling accessories are designed to work with InnovairFlex 4 -wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch.They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately).The AOS (Add -On Strobe) is an optional accessory included with the RTS2-AOS model. RA100Z/RA100ZA RTS151 RT5151KEY! RTS2 AOS RTS2-AOS Piezo Annunciator Mini -Horn, Red Mini -Horn, White Remote Annunciator Remote Test Station Remote Test Station with Key Multi -Signaling Accessory Add -On Strobe Multi -Signaling Accessory Agency Listings �L FM LISTED"""°"`° Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4 -wire conventional duct smoke detector applications without a system control panel, to comply with N FPA 90A. The MHR and MHW SpectrAlert Advance mini -horns feature temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single -gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RT5151 and RT5151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4 -wire detectors, the RTS151 KEY test station features a multi -colored LED that alternates between steady green and red. For 2 -wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi -signaling accessories are designed to work with InnovairFlex 4 -wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch.They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately).The AOS (Add -On Strobe) is an optional accessory included with the RTS2-AOS model. Specifications, Duct Smoke Detector Accessories Voltage Regulated 24VDC Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Operating Voltage 16 to 33 VDC Temperature Range Total Current: 105 mA max. Maximum Alarm Current 30 mA Test Switch 10 VA@32 VDC Temperature Range 0°C to 49-C (32°F to 1207) Reset Switch 10 VA @ 32 VDC Relative Humidity 10 to 93% non -condensing Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range —10°C to 6WC(I FFto 14G°F) Dimensions 4.6"Hx2.9-Wx.45-D Relative Humidity 95% non -condensing Maximum Alarm Current 12 mA Wire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage 8 t 33 VDC Test Power Requirements (9 to 33 VDC with Sync -Circuit' Module) Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC Temperature Range 17 mA RMS max. at 8 to 17.5 Volts FWR Relative Humidity 29 mA RMS max at 16 to 33 Volts DC Wire Gauge 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range 0°C to 49C (32'F to 120°F) Humidity Range 10 to 93% non -condensing Nominal Sounder Frequency 3kHz Wire Gauge 12 to 18 AWG Dimensions 4.6"Hx2.9"Wx0.45-D rr rr Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 12 mA Dimensions 4.6-Hx2.8-Wx 13-D Dimensions RTS151 KEY Remote 4.8-H x 2.90-W x 1.4-D Test Power Requirements Station with Key Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Alarm Response Time 40 seconds max Temperature Range —10°C to 60-C(WEto 140°F) Relative Humidity 95% non -condensing Wire Gauge 14 to 18 AWG Dimensions RTS2 and RTS2-A05 Multi Voltage 4.6-H x2.75"Wx 1.8-D -signaling Accessory 71 20to29VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60'C (WE to 140°F) Relative Humidity 95% non -condensing Wire Gauge 14to22AWG Dimensions 4.8-W x 5.3'H x 1.6-D For the very latest product specifications and listing information, please visit the System Sensor Web site at wwwsystemsensorcom. _•�..-. =Z__ RA100Z UL 52522 MHW UL S4011 MHRULS4011 RT52-AOS UL 52522 A05 .SYSTEM5= ^,o. 3825 Ohio Avenue•St, Charles, IL 60774 ®z.s=.11— vm^^isw�mrartasvera SENSOR Phone: 800-SENSOR2•Fax: 630-377-6495 am Kr^romanonmuwmy, i„ „ H�a,i,,,edias,. nosmz3 000. srw.a,wo CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE (9 LISTING No. 7315-0075:0510; 4__� Page 1 of 1 CATEGORY: 7315 — POWER UNITS LISTEE: FIRE -LITE ALARMS INC.One Fire -Lite Place, Northford, CT 06410-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models FL-POeli - S10 Power Supply Expander. Model Variations: Model FL-PS6: Maximum 6A Capacity; 5 Class B NAC's; 2 Command Inputs; Trouble and AC Loss Relays; Red Enclosure Model FL-PS10: Maximum 10A Capacity; 7 Class B NAC's; 3 Command Inputs; Trouble and AC Loss Relays; Red Enclosure 10-08-20 V W W This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed e the test results and/or other data but does not make an independent verification of any claims. This listing is not ,e an endorsement or recommendation of the item listed. This listing should not be used to verify correct " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Refer to listee's printed data sheet for detailed product description and operational considerations. RATING: Model FL-PS6: 120V AC, 50/60 Hz, 5.OA Maximum Model FL-PS10: 120V AC, 50/60 Hz, 6.2A Maximum INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a power supply extender when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7315-0028:0513 10-08-20 V W W This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed e the test results and/or other data but does not make an independent verification of any claims. This listing is not ,e an endorsement or recommendation of the item listed. This listing should not be used to verify correct " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE (9 LISTING No. 7165-0559:0135; �Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire -Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com DESIGN: Models 5820, 5820XL, IFP -1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, IFP -1000: Control Units 05820OP : Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor Intelliknight 5820 : Enclosure 5860/5860R/RA-1000: Annunciator 5496: Power Module 5824 : Serial/Parallel Interface 5895/5895XURPS-1000 : Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883 : Relay Interface Board SD500-ANM : Addressable Notification Module. SD500-LIM : Line Isolation Module SD505-61B : Isolation Base SD -500 SDM : Smoke Detector Module RA -100 : Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365 : Enclosure 'RBB : Battery Cabinet 5897, 5898: Power Supplies 058601: User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not ,!¢ an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation Instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice -Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTE: These control units can generate a distinctive three -pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL -864, 9th Edition Standards. For Fire Alarm Verification Feature (delay of fire alarm sional), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomerly 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. ,7300-0559:0132; �— Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire -Lite Place, Northford, CT 06472-1653 / Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email:lisa.brant@honeywell.com DESIGN: Model SD500-ARM Relay Module) 'SD50Q� CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 19 LISTING No. 7272-0559:0178,1 -�7� Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR -SYSTEM TYPE -PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITYOne Fire -Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email hsa.brant@honeywell.com DESIGN: ModelrS4505-FHOTd,� , p Otoelectric smoke detector for use with Model S1J50$-6AB) base. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 17.0 - 39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical/temperature rating and UL label. APPROVAL: - Listed as an analog photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units Hochiki Models FireNet Plus (CSFM No. 7165-0410:0180) and FireNet 4127 (CSFM No. 7165-0410:0159) . Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0410:0204 Is 10-22-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 9 LISTING No. 7125-07$5:0168, <—' Page 1 of 1 ............ .. CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Thomas Conover (941) 487-2336 Email: thomaslconover@eaton.com DESIGN: Exceder Series: Models ST strolaej H horn strobe and HN hornM at ST is a synchronous and non -synchronous strobe light. Model(HS)a visual/audible appliarice)and Model HN is an audible signal appliance. All units followed by R (red) or W)(white). Additionally, a'O may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional 'S' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, hom/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed s the test results and/or other data but does not make an independent verification of any claims. This listing is not „ elv an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY a FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE t§ LISTING No. 3550-1501:0137, Page 1 of 1 CATEGORY: 3550 — DOOR CLOSER/HOLDERS/RELEASING DEVICES LISTEE: EDWARD SIGNAL8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models 1501,A1501, 1502, 1504y 55, 15 ,door holders with or without suffixes AQ, N5, El, GI, E5, GT, D -GT or AF NS� far to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire -rated door holders. When used on fire -rated doors an approved closer shall be used. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly: 3550-1388:100, 3550-0073:040, 3550-0789:118, and 3550-0999:101 'Rev. 06-24-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed it the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 9 LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email- lisa.brant@honeywell.com DESIGN: Models RTS151, RTS151KEY and RA10OZ Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed it the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division