HomeMy WebLinkAboutF2022-0154 - Misc (2)Tyco MAW Worldwide Contacts I www.tyco-fire.com Series RFII — 5.6 K -factor "Royal Flush Il" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K -factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3 -mm bulb) and Standard Response (5 -mm bulb), are decorative sprinklers fea- turing a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensi- tive areas such as hotel lobbies, office buildings, churches, and restaurants. Each sprinkler includes a Cover Plate/ Retainer Assembly and a Sprinkler/ Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: • Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to Installation of a suspended ceiling or application of the finish coating to a fixed ceiling. • Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. • Provides for 1/2 in. (12,7 mm) of ver- tical adjustment to allow a measure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the 'INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of spnnklersystems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page i of 4 The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling installation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Pro- tective Cap. When ceiling installa- tion is complete, the Protective Cap is removed and the Cover Plate/Retainer Assembly is Installed. As an option, the Series RFII Standard Response (5 -mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. See Figure 5. The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. IMM The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owneris responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershould be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 — 3 mm bulb TY3551 — 5 mm bulb AUGUST 2020 Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Criteria section. • TY3531 (3 mm Bulb) is UL Listed, C -UL Listed and NYC Approved (MEA 353-01-E) as Quick Response. • TY3531 (3 mm Bulb) Is VdS Approved (Certificate No. G4090007). • TY3531 (3 mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) as Standard Response. Note: FM and LPCB do not approve concealed sprinklers for quick response. • TY3551 (5 mm Bulb) is UL Listed, C -UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C -UL Listed for use with the RFII Standard Response Concealed Sprinkler (TY3551) Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C -UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155"F (680C) Sprinkler with 139"F (59"C) Cover Plate 200°F (93"C) Sprinkler with 1650F (74°C) Cover Plate TFP181 TFP181 Page 2 of 4 Discharge Coefficient K= 5.6 GPM/psi1/2 (80,6 LPM/bart/2) Adjustment 1/2 in. (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ............................Bronze Support Cup ...... .............Plated Steel Guide Pins .................. Stainless Steel Deflector..........................Bronze Compression Screw .................. Brass Bulb. . ... . . ................. Glass Cap ......... ........... Bronze or Copper Sealing Assembly, . Beryllium Nickel w/TEFLON Cover Plate .........................Brass BULB Retainer. . - . - ............. Brass Ejection Spring .............. Stainless Steel Design Criteria The TYCO Series RFII 5.6 K -factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more Information on LPCB and VdS Approvals, contact Johnson Controls at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector — supported by the Guide Pins — then drops down to its operational position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. 1/2" NPT SEALING ASSEMBLY FRAME �\ CAP SUPPORT CUP WITH II BULB ROLL FORMED THREADS TT I COMPRESSION SCREW GUIDE ----""'� PINS (2) I DEFLECTOR DEFLECTORi Imo--- POSIITION) ------ _ SPRINKLER/SUPPORT CUP ASSEMBLY THREADINTO I RETAINER SUPPORT O WITH THREAD CUP UNTIL O DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING / SOLDER f TABS (3) COVER PLATE/RETAINER COVER PLATE ASSEMBLY FIGURE t MODEL RFII CONCEALED SPRINKLER ASSEMBLY Installation The TYCO Series RFII 5.6 K -factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb -type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 155°F (68°C) and 3/32 in. (2,4 mm) for the 200°F (93°C) temperature ratings. A leak -tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 Ib -ft (9,5 to 19,0 N -m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment In the Sprinkler by under- or over -tightening the Sprin- kler/Support Cup Assembly. Re -adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center -line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. Step 4. Wrench -tighten the sprinkler using only the RFII Sprinkler Wrench. See Figure 3. Apply the RFII Sprinkler Wrench to the Sprinkler. as shown in Figure 3. FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING DIMENSION C SPRINKLER SUPPORTCUP ASSEMBLY 1/2" (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE — L JL 3/16" to 11/16" MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32" (2,4 mm) POSITION ASSEMBLY COVER PLATE COVER PLATE PROFILE DEPTH DIAMETER DIMENSION B DIMENSION A A: 3-1/4 In. (82,6 mm) C:2-3/8 to 2-5/8 in. (60,3 to 66,7 mm) B: 3/16 In. (4,8 mm) D: 1-3/4 to 2-1/4 in. (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFP181 Page 3 of 4 Step S. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. See Figure 4. The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Pro- tective Cap. As long as the Protective Cap remains in place, the system is considered "Out of Service". Step 6. After the ceiling has been completed with the 2-1/2 in. (63,5 mm) diameter clearance hole and in prep- aration for installing the Cover Plate/ Retainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, see Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented accord- ing to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/ Retainer Assembly until the Retainer, shown in Figure 2, or the Air and Dust Seal, shown in Figure 5, contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly suf- ficiently to contact the ceiling, you must reposition the Sprinkler Fitting. TFP181 Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT CUP — / CEILING SEAL BEVEL AS COVER '; SHOWN PLATE ' RETAINER ASSEMBLY /AIR AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) Care and Maintenance The TYCO Series RFII 5.6 K -factor, "Royal Flush II" Concealed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 in. (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation Section. Exercise care to avoid damage to sprin- klers before, during, and after instal- lation. Replace sprinklers damaged by dropping, striking, wrench twist- ing, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from Its bulb. See the Installation section. If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace It immediately. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating, P/N` (specify): 155T WO'CI 20TF 193.0) TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Use suffix "I" for ISO 7-1 connection; for example, 51-792-1-155-1 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from below) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139-F (69°C)(a) 166-F (74°10)(b) Grey White (RAL9002).... 56-792-0-135 56-792-0-166 Brushed Brass.. 56-792-1-135 56-792-1-165 Brass.....,.... 56-792-2-135 56-792-2-165 Pure White (c) (RAL9010).... 56-792-3-135 56-792-3-165 Signal White (RAL9003).... 56-7924-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 56-792-6-165 Brushed Chrome........ 56-792-8-135 56-792-8-165 Chrome........ 56-792-9-135 56-792-9-165 Custom ........ 56-792-X-135 56-792-X-165 (a) For use with 155°F (68aC) sprinklers. (b). For use with 200aF (93aC) sprinklers. (c) Eastern Hemisphere sales only, Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075 Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 {. 09=JeMuen eon Vola. All rabb...mad. latormwe atlonall. re ca—M At at CPounmotr".an data and am subleot to AMnpawHbeN notice. Johnson ��♦♦/' a...LL PP.t r.. ASSe .... and LAIPA en IpYYwdtrWam. of elbA., I..m ..,.a.: Controls IEFlMiI..,e96Mdved.mMa, ouPom s Firel-ock® V27, K5.6 x.4065 licr Models V2703, V2707, V2704, V2708 40.10 Y V2703/V2704 V2707/V2708 V2707/V2708 V2707/V2708 V2703/V2704 Upright Pendent Recessed Pendent Pendent w/V9 Upright w/V9 1.0 PRODUCT DESCRIPTION Models: V2703, V2704, V27O7, V27O8 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2713 mm K Factor: 5.6 Imp./8.1 S.1.1 Nominal Connection Size: 1/2" NPT/20 mm BSPT/IGS Grooved Max. Working Pressure: • 175 psi/1200 kPa (FM) • 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Min. Operating Pressure: • 7 psi/48 kPa • 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart I For K -Factor when pressure is measured In Bar, multiply S.I. units by 10.0. 2.0 CERTIFICATION/LISTINGS oQu FM> FL—PCB] ® vdsUMB 0786 E Threaded and IGS connections have different approvals/listings. See tables on pages 2 and 3. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System NoT. Spec Section Paragraph El Submitted By Date Approved Date Victaulic.com 40.10 2544 Rev L Updated 04/2020 02020 Victaulic Company. All rights reserved. �CtBIJliC 1 victaulic.cam 2.0 CERTIFICATIOWLISTINGS (CONTINUED) Threaded Sprinkler Approvals/Listings: APPROVALS/LISTINGS Model V2703 V2707 V2707 V2704 V2708 V27082 Orifice Size (Inches) '/2" 1/2" Vi' 1/2' 1/2" 42" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 _ 5.6 Nominal K Factor 5.1.2 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C cULus 200°F/93°C 200°F/93°C 175°F/79°C 1757/79°C 175°H79°C 155°F/68°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 500°F/260°C 500°F/260°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C FM 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 1357/57°C NYC/MEA 62-99-E 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C. 286°F/141°C ° 200°F/93C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C CSFM 7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 3607/182°C 360°F/182°C 135°F/57°C 155°F/68°C 135°F/57°C LPCB 175°F/79°C None None 155°F/68°C None None 200°F/93°C 175°F/79°C 286°F/141°C 200°F/93°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68°C None 155°F/68°C 155°F/68°C None 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C Vd5 175°F/79°C None None 175°F/79°C None None 200°F/ C°C 200°F/93°C 286°F/14411 ° 286F/141°C 360°F/182°C 135°F/57°C 155°F/68°C 135°F/57°C 175°F/79°C 155°17/68°C CE 200°F/93°C None None 175°F/79°C None None 286°F/141°C 200°F/93°C 360°F/182°C 286°F/141°C 2 For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 2 FM Approved with 1Y adjustment escutcheon only - quick response NOTE .Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev L Updated 04/2020 0 2020 Victaulic Company. All rights reserved. victaulic.com Jctaulic victaulic.com 2.0 CERTIFICATION/LISTINGS (CONTINUED) IGS Sprinkler Approvals/Listings t For K -Factor when pressure Is measured In bar, mul8piy S.I. units by 10.0 NOTE • Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev L Updated 04/2020 ® 2020 Vlctaulic Company. All rights reserved. victaulic.com Model APPROVALS/LISTINGS V2703 V2707 V2704 V2708 Orifice Size (inches) Vz' '/i' ile Yx" Orifice Size (mm) _ 13 13 13 _ 13 Nominal K -Factor Imperial 5.6 5.6 5.6 5.6 Nominal K -Factor 5.1.' 8.1 8.1 8.1 8.1 Response Standard Standard Quick Quick Deflector Type Upright Pendent Upright Pendent Adjustment Approved Temperature Ratings F'/C' 135'F/57°C 135°F/57'C 155'F/68'C 155°F/68°C 135°F/57°C 135'F/57°C 175'F/79'C 175°F/79°C 155°F/68°C 155°F/68°C cULus 200'F/93'C 200°F/93'C 175°F/79°C 175°F/79°C 286'F/141'C 286°F/141°C 200°F/93°C 200°F/93°C 360°F/182'C 360'F/182°C 286'F/141°C 286°F/141'C 500°F/260'C 500°F/260'C 135°F/57'C 135'F/57°C 135°F/57'C 135°F/57°C 155'F/68'C 155'F/68'C 155°F/68'C 155'F/68°C FM 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93'C 286'F/141'C 286°F/141°C 286°F/141°C 286°F/141'C 360'F/182'C 360°F/182°C t For K -Factor when pressure Is measured In bar, mul8piy S.I. units by 10.0 NOTE • Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev L Updated 04/2020 ® 2020 Vlctaulic Company. All rights reserved. victaulic.com victaulic.com 3.0 SPECIFICATIONS — MATERIAL Upright Deflector: Bronze Pendent Deflector: Bronze Bulb: Glass with glycerin solution Bulb Nominal Diameter: ❑ Standard: 5.0 mm ❑ Quick Response: 3.0 mm Load Screw: Bronze Pip Cap: Bronze Spring: Beryllium nickel Seal: PTFE tape Frame: Die cast brass Lodgement Spring: Stainless steel Installation Wrench: ❑ Open End: V27 ❑ Recessed: V27-2 ❑ 3/,e Hex Bit: V9 coupling Sprinkler Finishes: ❑ Plain Brass4 ❑ Chrome plated ❑ White polyester coated5 ❑ Black painted5 ❑ Custom painted5 ❑ VC -2506 4 Plain Brass is only available for the V9 coupling. a UL Listed for corrosion resistance. 6 UL Listed and FM Approved for corrosion resistance. Exaggerated for clarity 40.10 2544 Rev L Updated 04/2020 ® 2020 Victaulic Company. All rights reserved. victaulic.com 4 �ctaulllcr victaulic.com 4.0 DIMENSIONS 6r PAY 41 60 mm 111'4 i 37 mm 25 mm f J Standard Pendent with/Without standard V9 coupling— V2707, V2708 Standard Upright with/without standard V9 coupling — V2703, V2704 NOTE: • V27, K5.6 sprinklers with Style V9 coupling dimensions are the same as threaded sprinkler dimensions. n 24 MAXIMUM EMENSION Ya' Adjustment Recessed - V2707, V2708 (drawing not to scale) Nee 24mm 75mm MAXIMUM 1 X 14510N 4'4' Adjustment Recessed—V2707, V2708 (drawing not to scale) Standard Pendent with V9 Sprinkler Coupling—V2707, V2708 Standard Upright with V9 Sprinkler Coupling— V2703, V2704 NOTE: • IGS options are not available for recessed applications. 40.10 2544 Rev L Updated 04/2020 0 2020 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctaulid victaulic.com 5.0 Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS • Always read and understand Installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. • Installation rules, especially those governing obstruction, must be strictly followed. • Painting, plating, or any re -coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this _ product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: _ 001.610-559-3300. 40.10 2544 Rev L Updated 04/2020 ® 2020 Victaulic Company. All rights reserved. victaulic.com 6 XAotauhcr victaulic.com 7.0 REFERENCE MATERIALS Ratings All glass bulbs are rated for temperatures from—650F/-540C to those shown in table below. Sprinkler victaulic Temperature Part __Classification Identification Temperature -°FPC Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135°F/570C 10fPF/38°C Orange, -Ordinary C 155°F/68°C 100°F/38°C Red Intermediate E 175°F/79°C 150°17/69C Yellow Intermediate F 200°F/93°C 150°F/65°C Green Nigh 1 286°F/141°C 225°Fa/107°C Blue. Extra HIgh7 K 360°F/182°C 300°F/149°C Purple - M Open No bulb Ultra HIgh7 N 500°F/260°C 475°F/246°C Black 7 Standard response only. Available Wrenches: Sprinkler Type V27-2 Recessed V27 Open End Hex -Bit V2707,V2708 Pendent ✓ ✓ - V2707, V2708 Recessed Pendent ✓ - - V2703, V2704 Upright - ✓ - V2703, V2704 Upright w/V9 - - ✓ V2707, V2708 Pendent w/V9 ✓ NOTE e aha -Inch hex bit provided with V9 coupling shipment. 29.01: Victaulic Terms and Conditions of Sale 1-40: Victaulic FireLockl- Automatic Sprinklers V9 Style V9 victaul c Fire Lock' IGS I nstrallation-Readyna Sprinkler Coupine Installation Instructions User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Vletaulle products for a particular and -use application, In accordance with Industry standards and protect specifications, and the applicable building codes and related regulators as well as Vleteulle performance, maintenance, safety, and warning Instructions. Nothing In this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Vlctaullc Company's standard conditions of sale, Installation gulde, or this disclaimer. Intellectual Properly Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is Intended, or should be constructed, to gram any license under any patent or other Intellectual property right of Victaulic or any of Its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such mstarle, product, service, or design In the Infringement of any patent or other Intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility parents or parent applications for articles and/or methods of use In the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed In accordance with current Victaulic installation/assembly Instructions. volatile reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Viclaulic installation handbook or Installation Instructions of product you are Installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format an our website at www.victaulipcom. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. hademarks Wafaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or Its affiliated entitles, In the U.S. and/or other countries. 40.10 2544 Rev L Updated 04/2020 0 2020 Victaulic Company. All rights reserved. victaulic.com 7 ✓ctaulia Hydraulic Calculations by HydraCALC A&D FIRE SPRINKLERS INC 1601 W ORANGEWOOD AVE C16 1069002 ORANGE,CA,92868 714-634-3923 Job Name LAD1699 - HRC CLINIC—recover Drawing Location Remote Area Contract Data File LAD1699 - HRC CLINIC recover Area 1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.2 M X c 0 m m A v N W A N M V W M—+ ' —+ n O O O O O O O O O O O _ N O O W O A O 0Iz O CC 000 n W � CD cn W N C CD o aaci� n0y 0 Cn CM O N fD C N 01 (n dV M V ~Olin O O N Ol O T r O w O z >o 6 0 w 0 A O O 3 cnvxvvv� O N N! NW N i a i<nr° m co m Kfi Oyu mu No 3y330 om'uTm ma@o 3�1 C c CLpj � �W OOA ODA :-. W o A o A C A p Cc o MZ -V-1� O C -immco > _a o o Nc m O � iso 3 �c 2. N 2 2� y 3 'ON a C�fD C r N W 0 Jx C: CD C @ '� D U3 C:Fn C:3 vvvv 3 m 3a J r y m DDaa 0< 0) co O W W W W J-d-Ci.J N y 0 0 W 00 OF OC CD .0+CD 7'a �W c d0'o om 5'i3 g M 0 < ���mCD 2xaw C, -M .» CD W J WW i MM N 0 U3 W a Ol cCL m E ao y < 01 W ._'2, a. N 33vO J Wo "o N d N O '"` •-• O� 0CnCD J (/J CD x O. W .O G fOD S ~N f0/ [] [WY N a0 y N :E� AONO w S W i W CD a CL »3 Er3 c W NNNO J CD07 W O w fnQ fD »O N J n N c W V W O e 0 W W J' O J 'Cc 06 CL a J O :E C) J' r,�a O W nW =`: WtOAO mnM my wCCLCD O 400 J N CD8 -00 N 9 N D SU W a C N I a < O <.n3 J N 0 3 V w C !016N W O fD 0 @ W O W 0 V W u O N O N A fNI�V NW N O N A O 0 MOM" 0 O M NN — O OfOTrN N O O A W A O � N W O O O 00 N -+ N A Flow Summary - NFPA A&D FIRE SPRINKLERS INC Page 3 LAD1699 - HRC CLINIC recover Date SUPPLYANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure BOR 57.5 56.5 Node Tag Elevation Node Type 187.0 55.375 281.06 34.744 NODE ANALYSIS Pressure Discharge at Node at Node Notes 1 9.5 5.6 16.14 22.5 2 12.0 20.97 3 12.0 21.16 4 12.0 21.33 5 12.0 22.26 6 12.0 22.4 7 12.0 22.49 8 12.0 22.54 9 12.0 22.57 10 12.0 22.59 11 12.0 22.61 12 12.0 22.61 13 12.0 22.61 14 12.0 22.73 15 12.0 22.73 16 12.0 22.73 17 12.0 22.75 18 12.0 22.77 19 12.0 22.8 20 12.0 23.45 21 12.0 23.54 22 12.0 23.67 23 12.0 23.91 24 12.0 24.29 25 12.0 24.78 26 12.0 25.45 TOR 0.5 31.04 BOR 0.0 34.74 100.0 27 9.5 5.6 16.14 22.5 28 12.0 20.97 29 12.0 21.16 30 9.5 5.6 16.27 22.59 31 12.0 21.14 32 12.0 22.24 33 12.0 22.26 34 12.0 22.26 35 12.0 22.28 36 9.5 5.6 16.17 22.52 37 12.0 21.0 38 12.0 21.2 39 12.0 21.35 40 9.5 5.6 16.17 22.52 Computer Programs by Hydratec Inc. Revision: 50.54.2 Flow Summary - NFPA A&D FIRE SPRINKLERS INC Page 4 LAD1699 - HRC CLINIC recover Date NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 41 12.0 21.01 42 12.0 21.2 43 9.5 5.6 16.29 22.6 44 12.0 21.16 45 9.5 5.6 16.74 22.91 46 12.0 21.77 47 12.0 22.0 48 9.5 5.6 16.74 22.91 49 12.0 21.77 50 12.0 22.0 Computer Programs by Hydratec Inc. Revision: 50.54.2 Final Calculations: Hazen -Williams A&D FIRE SPRINKLERS INC LAD1699 - HRC CLINIC recover Page 5 Date Nodal Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ***"" Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 9.5 5.60 22.50 1 E 2.0 2.500 120 16.143 to Eql 32.0 34.000 -1.083 2 12 22.5 1.049 0.0 36.500 0.1618 5.907 Vel = 8.35 2 12 0.0 1.5 T 9.9 2.120 120 20.967 to 0.0 9.900 0.0 3 12 22.5 1.682 0.0 12.020 0.0162 0.195 Vel = 3.25 3 12 -1.41 1.5 0.0 12.000 120 21.162 to 0.0 0.0 0.0 4 12 21.09 1.682 0.0 12.000 0.0144 0.173 Vel = 3.05 4 12 22.59 1.5 T 9.9 6.840 120 21.335 to 0.0 9.900 0.0 5 12 43.68 1.682 0.0 16.740 0.0554 0.927 Vel = 6.31 5 12 22.71 2.5 0.0 10.000 120 22.262 to 0.0 0.0 0.0 6 12 66.39 2.635 0.0 10.000 0.0135 0.135 Vel = 3.91 6 12 -13.50 2.5 0.0 10.000 120 22.397 to 0.0 0.0 0.0 7 12 52.89 2.635 0.0 10.000 0.0089 0.089 Vel = 3.11 7 12 -12.32 2.5 0.0 10.000 120 22.486 to 0.0 0.0 0.0 8 12 40.57 2.635 0.0 10.000 0.0054 0.054 Vel = 2.39 8 12 -8.98 2.5 0.0 10.000 120 22.540 to 0.0 0.0 0.0 9 12 31.59 2.635 0.0 10.000 0.0034 0.034 Vel = 1.86 9 12 -7.61 2.5 0.0 10.000 120 22.574 to 0.0 0.0 0.0 10 12 23.98 2.635 0.0 10.000 0.0020 0.020 Vel = 1.41 10 12 -6.69 2.5 0.0 10.000 120 22.594 to 0.0 0.0 0.0 11 12 17.29 2.635 0.0 10.000 0.0012 0.012 Vel = 1.02 11 12 -6.13 2.5 0.0 10.000 120 22.606 to 0.0 0.0 0.0 12 12 11.16 2.635 0.0 10.000 0.0005 0.005 Vel = 0.66 12 12 -5.87 2.5 0.0 10.000 120 22.611 to 0.0 0.0 0.0 13 12 5.29 2.635 0.0 10.000 0.0001 0.001 Vel = 0.31 13 12 0.0 1.5 2T 16.0 67.860 120 22.612 to 0.0 16.000 0.0 14 12 5.29 1.61 0.0 83.860 0.0014 0.116 Vel = 0.83 14 12 0.0 2.5 0.0 10.000 120 22.728 to 0.0 0.0 0.0 15 12 5.29 2.635 0.0 10.000 0.0001 0.001 Vel = 0.31 15 12 5.87 2.5 0.0 10.000 120 22.729 to 0.0 0.0 0.0 16 12 11.16 2.635 0.0 10.000 0.0005 0.005 Vel = 0.66 16 12 6.13 2.5 0.0 10.000 120 22.734 to 0.0 0.0 0.0 17 12 17.29 2.635 0.0 10.000 0.0011 0.011 Vel = 1.02 Computer Programs by Hydratec Inc. Revision: 50.54.2 Final Calculations: Hazen -Williams A&D FIRE SPRINKLERS INC Page 6 fAD1699 - HRC CLINIC recover Date Nadel Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 17 12 6.69 2.5 0.0 10.000 120 22.745 to 0.0 0.0 0.0 18 12 23.98 2.635 0.0 10.000 0.0021 0.021 Vel = 1.41 18 12 7.61 2.5 0.0 10.000 120 22.766 to 0.0 0.0 0.0 19 12 31.59 2.635 0.0 10.000 0.0034 0.034 Vel = 1.86 19 12 8.98 2.5 2E 16.474 103.330 120 22.800 to 0.0 .16.474 0.0 20 12 40.57 2.635 0.0 119.804 0.0054 0.650 Vel = 2.39 20 12 12.32 2.5 0.0 10.000 120 23.450 to 0.0 0.0 0.0 21 12 52.89 2.635 0.0 10.000 0.0089 0.089 Vel = 3.11 21 12 13.50 2.5 0.0 10.000 120 23.539 to 0.0 0.0 0.0 22 12 66.39 2.635 0.0 10.000 0.0135 0.135 Vel = 3.91 22 12 23.91 2.5 0.0 10.000 120 23.674 to 0.0 0.0 0.0 23 12 90.3 2.635 0.0 10.000 0.0238 0.238 Vel = 5.31 23 12 24.93 2.5 0.0 10.000 120 23.912 to 0.0 0.0 0.0 24 12 115.23 2.635 0.0 10.000 0.0375 0.375 Vel = 6.78 24 12 18.42 2.5 0.0 10.000 120 24.287 to 0.0 0.0 0.0 25 12 133.65 2.635 0.0 10.000 0.0492 0.492 Vel = 7.86 25 12 23.96 2.5 0.0 10.000 120 24.779 to 0.0 0.0 0.0 26 12 157.61 2.635 0.0 10.000 0.0669 0.669 Vel = 9.27 26 12 23.45 2.5 0.0 7.130 120 25.448 to 0.0 0.0 4.981 TOR .500 181.06 2.635 0.0 7.130 0.0863 0.615 Vel = 10.65 TOR .500 0.0 2.5 B 9.61 11.500 120 31.044 to S 19.22 28.830 0.217 BOR 0 181.06 2.635 0.0 40.330 0.0864 3.483 Vel = 10.65 100.00 Qa = 100.00 BOR 281.06 34.744 K Factor= 47.68 27 9.5 5.60 22.50 1 E 2.0 2.500 120 16.144 to Eql 32.0 34.000 -1.083 28 12 22.5 1.049 0.0 36.500 0.1618 5.907 Vel = 8.35 28 12 0.0 1.5 T 9.9 2.120 120 20.968 to 0.0 9.900 0.0 29 12 22.5 1.682 0.0 12.020 0.0162 0.195 Vel = 3.25 29 12 1.41 1.5 T 9.9 128.350 120 21.163 to 0.0 9.900 0.0 22 12 23.91 1.682 0.0 138.250 0.0182 2.511 Vel = 3.45 0.0 22 23.91 23.674 K Factor= 4.91 30 9.5 5.60 22.59 1 E 2.0 2.500 120 16.271 to Eql 32.0 34.000 -1.083 31 12 22.59 1.049 0.0 36.500 0.1630 5.950 Vel = 8.39 Computer Programs by Hydratec Inc. Revision: 50.54.2 Final Calculations: Hazen -Williams A&D FIRE SPRINKLERS INC Page 7 -IAD1699 - HRC CLINIC recover Date Nodal Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 31 12 0.0 1.5 T 9.9 2.120 120 21.138 16.171 to to 0.0 9.900 32.0 0.0 -1.083 4 12 22.59 1.682 0.0 12.020 0.0164 0.197 Vel = 3.26 5.916 Vel = 0.0 37 12 0.0 1.5 T 9.9 1.880 4 21.004 22.59 to 21.335 K Factor= 4.89 3 12 1.41 1.5 0.0 14.000 120 21.162 22.52 1.682 to 0.0 11.780 0.0163 0.0 0.0 3.25 0.0 12 -2.41 29 12 1.41 1.682 0.0 14.000 0.0001 0.001 Vel = 0.20 0.0 0.0 0.0 0.0 39 29 20.11 1.41 0.0 12.000 0.0132 21.163 K Factor= 0.31 5 12 -22.71 2.5 0.0 10.000 120 22.262 120 21.354 to to 0.0 0.0 0.0 9.900 32 12 -22.71 2.635 0.0 10.000 -0.0019 -0.019 Vel = 1.34 32 12 42.71 2.5 0.0 10.000 120 22.243 to 0.0 0.0 0.0 33 12 20.0 2.635 0.0 10.000 0.0015 0.015 Vel = 1.18 33 12 -18.41 2.5 0.0 10.000 120 22.258 to 32.0 34.000 0.0 0.0 0.0 12 22.52 34 12 1.59 2.635 0.0 10.000 0 0.0 Vel = 0.09 34 12 21.85 2.5 0.0 10.000 120 22.258 to to 0.0 0.0 0.0 35 12 23.44 2.635 0.0 10.000 0.0020 0.020 Vel = 1.38 35 12 0.0 1.5 2T 19.799 161.190 120 22.278 to 0.0 19.799 0.0 26 12 23.44 1.682 0.0 180.989 0.0175 3.170 Vel = 3.38 0.0 25.448 K Factor= 4.65 36 9.5 5.60 22.52 1 E 2.0 2.500 120 16.171 to Eql 32.0 34.000 -1.083 37 12 22.52 1.049 0.0 36.500 0.1621 5.916 Vel = 8.36 37 12 0.0 1.5 T 9.9 1.880 120 21.004 to 0.0 9.900 0.0 38 12 22.52 1.682 0.0 11.780 0.0163 0.192 Vel = 3.25 38 12 -2.41 1.5 0.0 12.000 120 21.196 to 0.0 0.0 0.0 39 12 20.11 1.682 0.0 12.000 0.0132 0.158 Vel = 2.90 39 12 22.60 1.5 T 9.9 6.840 120 21.354 to 0.0 9.900 0.0 32 12 42.71 1.682 0.0 16.740 0.0531 0.889 Vel = 6.17 0.0 32 42.71 22.243 K Factor= 9.06 40 9.5 5.60 22.52 1 E 2.0 2.500 120 16.174 to Eql 32.0 34.000 -1.083 41 12 22.52 1.049 0.0 36.500 0.1621 5.917 Vel = 8.36 41 12 0.0 1.5 T 9.9 1.880 120 21.008 to 0.0 9.900 0.0 42 12 22.52 1.682 0.0 11.780 0.0162 0.191 Vel = 3.25 Computer Programs by Hydratec Inc. Revision: 50.54.2 Final Calculations: Hazen -Williams A&D FIRE SPRINKLERS INC 12 1.06 1.5 0.0 12.000 120 22.001 Page 8 ILAD1699 - HRC CLINIC recover 0.0 0.0 0.0 47 Date 1.06 Nodal Elev1 K Qa Nom Fitting Pipe CFact Pt to 47 1.06 or Ftngs 22.001 K Factor= 0.23 Pe *'***** Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 19.799 42 12 12 2.41 1.5 T 9.9 128.350 120 21.199 to 0.0 9.900 0.0 23 12 24.93 1.682 0.0 138.250 0.0196 2.713 Vel = 3.60 0.0 23 24.93 23.912 K Factor = 5.10 43 9.5 5.60 22.60 1 E 2.0 2.500 120 16.288 to Eql 32.0 34.000 -1.083 44 12 22.6 1.049 0.0 36.500 0.1632 5.956 Vel = 8.39 44 12 0.0 1.5 T 9.9 1.880 120 21.161 to 0.0 9.900 0.0 39 12 22.6 1.682 0.0 11.780 0.0164 0.193 Vel = 3.26 0.0 39 22.60 21.354 K Factor= 4.89 38 12 2.41 1.5 0.0 14.000 120 21.196 to 0.0 0.0 0.0 42 12 2.41 1.682 0.0 14.000 0.0002 0.003 Vel = 0.35 0.0 42 2.41 21.199 K Factor= 0.52 45 9.5 5.60 22.91 1 E 2.0 2.500 120 16.741 to Eql 32.0 34.000 -1.083 46 12 22.91 1.049 0.0 36.500 0.1673 6.108 Vel = 8.50 46 12 0.0 1.5 T 9.9 4.120 120 21.766 to 0.0 9.900 0.0 47 12 22.91 1.682 0.0 14.020 0.0168 0.235 Vel = 3.31 47 12 1.06 1.5 T 9.9 142.350 120 22.001 to 0.0 9.900 0.0 25 12 23.97 1.682 0.0 152.250 0.0182 2.778 Vel = 3.46 0.0 25 23.97 24.779 K Factor= 4.82 48 9.5 5.60 22.91 1 E 2.0 2.500 120 16.740 to Eql 32.0 34.000 -1.083 49 12 22.91 1.049 0.0 36.500 0.1673 6.108 Vel = 8.50 49 12 0.0 1.5 T 9.9 4.120 120 21.765 to 0.0 9.900 0.0 50 12 22.91 1.682 0.0 14.020 0.0168 0.236 Vel = 3.31 50 12 -1.05 1.5 T 9.9 6.840 120 22.001 to 0.0 9.900 0.0 34 12 21.86 1.682 0.0 16.740 0.0154 0.257 Vel = 3.16 0.0 f'�JV�.Y:1•:��T3i.Tg�:k1 50 12 1.06 1.5 0.0 12.000 120 22.001 to 0.0 0.0 0.0 47 12 1.06 1.682 0.0 12.000 0 0.0 Vel = 0.15 0.0 47 1.06 22.001 K Factor= 0.23 33 12 18.42 1.5 2T 19.799 161.190 120 22.258 to 0.0 19.799 0.0 24 12 18.42 1.682 0.0 180.989 0.0112 2.029 Vel = 2.66 Computer Programs by Hydratec Inc. Revision: 50.54.2 Final Calculations: Hazen -Williams A$D FIRE SPRINKLERS INC I.AD1699 - HRC CLINIC recover Page 9 Date Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to 161.190 or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 24 18.42 24.287 K Factor= 3.74 6 12 13.50 1.5 2T 19.799 161.190 120 22.397 to 0.0 19.799 0.0 21 12 13.5 1.682 0.0 180.989 0.0063 1.142 Vel = 1.95 0.0 21 13.50 23.539 K Factor= 2.78 7 12 12.32 1.5 2T 19.799 161.190 120 22.486 to 0.0 19.799 0.0 20 12 12.32 1.682 0.0 180.989 0.0053 0.964 Vel = 1.78 0.0 20 12.32 23.450 K Factor= 2.54 8 12 8.98 1.5 2T 19.799 67.860 120 22.540 to 0.0 19.799 0.0 19 12 8.98 1.682 0.0 87.659 0.0030 0.260 Vel = 1.30 0.0 19 8.98 22.800 K Factor= 1.88 9 12 7.61 1.5 2T 19.799 67.860 120 22.574 to 0.0 19.799 0.0 18 12 7.61 1.682 0.0 87.659 0.0022 0.192 Vel = 1.10 0.0 18 7.61 22.766 K Factor= 1.59 10 12 6.69 1.5 2T 19.799 67.860 120 22.594 to 0.0 19.799 0.0 17 12 6.69 1.682 0.0 87.659 0.0017 0.151 Vel = 0.97 0.0 17 6.69 22.745 K Factor= 1.40 11 12 6.13 1.5 2T 19.799 67.860 120 22.606 to 0.0 19.799 0.0 16 12 6.13 1.682 0.0 87.659 0.0015 0.128 Vel = 0.89 0.0 16 6.13 22.734 K Factor= 1.29 12 12 5.87 1.5 2T 19.799 67.860 120 22.611 to 0.0 19.799 0.0 15 12 5.87 1.682 0.0 87.659 0.0013 0.118 Vel = 0.85 0.0 15 5.87 22.729 K Factor= 1.23 Computer Programs by Hydratec Inc. Revision: 50.54.2