HomeMy WebLinkAbout09_Bakshi Residence Coastal Development Permit_PA2018-057CITY OF NEWPORT BEACH
ZONING ADMINISTRATOR STAFF REPORT
May 10, 2018
Agenda Item No. 9
SUBJECT: Bakshi Residence (PA2018-057)
SITE LOCATION:
Coastal Development Permit No. CD2018-022
127 Jade Avenue
APPLICANT: Brandon Architects, Inc.
OWNER: Bob Bakshi
PLANNER: Liane Schuller, Contract Planner
949-644-3237, lschuller@newportbeachca.gov
LAND USE AND ZONING
General Plan: RT (Two-Unit Residential)
Zoning District : R-BI (Balboa Island)
Coastal Land Use Category: RT-E (Two Unit Residential - 30.0 - 39.9 DU/AC)
Coastal Zoning District: R-BI (Balboa Island)
PROJECT SUMMARY
The applicant requests a coastal development permit (CDP) to allow the demolition of an
existing two-story residential duplex, and the construction of a new three-story, 2,329-
square-foot, single-family residence and attached 397-square-foot, two-car garage. The
project will include hardscape, landscape and subsurface drainage facilities all located
within the confines of private property. The design complies with all applicable
development standards and no deviations are requested. All improvements are shown on
the attached project plans (Attachment No. ZA 4).
RECOMMENDATION
1)Conduct a public hearing;
2)Find this project exempt from the California Environmental Quality Act (CEQA)
pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small
Structures), because it has no potential to have a significant effect on the environment;
and
3)Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development
Permit No. CD2018-022 (Attachment No. ZA 1).
1
Bakshi Residence
Zoning Administrator, May 10, 2018
Page 2
DISCUSSION
Land Use and Development Standards
The project is located in the R-BI Zoning District, which allows a maximum of two
residential dwelling units on a single legal lot, and is consistent with the City’s Coastal
Land Use Plan, General Plan, and Zoning Code. A CDP is required and the property
is not eligible for a Waiver for De Minimis Development because the property is
located in the Appeal Area.
The property consists of one legal lot containing an existing two-story residential
duplex. The neighborhood is predominantly developed with two- and three-story
single- and two-family residences. The proposed design, bulk, and scale of the
development is consistent with the existing neighborhood pattern of development
and expected future development because the development meets all
development standards for the construction of a single-family residence.
The proposed single-family residence and accessory structures conform to all
applicable development standards, including floor area limit, setbacks, height, and
off-street parking as evidenced by the project plans and illustrated in Table 1 below:
Table 1 – Development Standards
Development Standard Standard Proposed
Setbacks (min.)
Front 10 feet 10 feet
Sides 3 feet 3 feet
Rear 5 feet 5 feet
Floor Area 2,726 square feet 2,726 square feet
Open Volume Area Not applicable (R-BI) N/A
Allowable Third Floor Area Not applicable (R-BI) N/A
Parking 2-car garage 2-car garage
Height 24 feet flat roof
29 feet sloped roof
24 feet flat roof
29 feet sloped roof
Hazards
The project site is located approximately 140 feet from the bay front and is separated
from the water by Jade Avenue, East Bay Front alleyway, a row of existing residential
development and the Bay Front promenade.
The finished first floor elevation of the interior living area of the proposed residence
is 9.00 feet based on the North American Vertical Datum of 1988 (NAVD88), which
complies with the minimum required 9.00-foot (NAVD88) elevation standard. The
finished floor elevation of the garage (i.e., not living area) is 7.86 feet (NAVD88)
with an approximately 2-percent slope driveway connecting to the existing alley.
2
Bakshi Residence
Zoning Administrator, May 10, 2018
Page 3
The property is located in an area known for the potential of seismic activity and
liquefaction. All projects are required to comply with the California Building Code
(CBC) and Building Division standards and policies. Geotechnical investigations
specifically addressing liquefaction are required to be reviewed and approved prior
to the issuance of building permits. Permit issuance is also contingent on the
inclusion of design mitigation identified in the investigations. Construction plans are
reviewed for compliance with approved investigations and CBC prior to building
permit issuance.
Water Quality
The project design addresses water quality with a construction erosion control plan
that outlines temporary Best Management Practices (BMPs) to be implemented
during construction to minimize erosion and sedimentation, and to minimize
pollution of runoff derived by construction chemicals and materials. No water
quality impacts to coastal waters are anticipated based upon the location and
elevation of the property.
The property is not located on the shoreline nor is it located within 100 feet of coastal
waters. The project design addresses water quality with a construction erosion
control plan and a post construction drainage system that includes drainage and
percolation features designed to retain dry weather and minor rain event run-off on-
site. Any water not retained on-site is directed to the City’s storm drain system.
Public Access
The project site is an inland lot on Balboa Island, and is located between the nearest
public road and the sea or shoreline. The existing residential development neither
provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040
(Determination of Public Access/Recreation Impacts) requires that the provision of
public access bear a reasonable relationship between the requirement and the
project’s impact and be proportional to the impact. In this case, the project replaces
an existing residential duplex with a new single-family residence. Therefore, the
project does not involve a change in land use, density or intensity that will result in
increased demand on public access and recreation opportunities. Furthermore, the
project is designed and sited so as not to block or impede existing public access
opportunities.
The residential lot does not currently provide nor does it inhibit public coastal access.
Lateral access is provided by the nearby bay front public sidewalk and public beach.
Vertical access to the bay front area is provided at various public street-ends
throughout Balboa Island, with the nearest vertical access provided along Park
Avenue immediately north of the project site.
The project site is not located adjacent to a coastal view road, public viewpoint, public
park or beach, or public accessway, as identified in the Coastal Land Use Plan.
3
Bakshi Residence
Zoning Administrator, May 10, 2018
Page 4
Furthermore, an investigation of the project site and surrounding area did not identify
any other public view opportunities. The project site may be located within the
viewshed of distant public viewing areas. However, the project will replace an existing
residential duplex with a new single-family residence that complies with all applicable
Local Coastal Program development standards and maintains a building envelope
consistent with the existing neighborhood pattern of development. Therefore, the
project does not have the potential to degrade the visual quality of the Coastal Zone
or result in significant adverse impacts to public views.
ENVIRONMENTAL REVIEW
This project is exempt from the California Environmental Quality Act (CEQA) pursuant to
Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of
the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has
no potential to have a significant effect on the environment.
Class 3 exempts the construction and location of limited numbers of new, small facilities
or structures including one single-family residence in a residential zone. The proposed
project consists of the demolition of an existing residential duplex and construction of a
new three-story, 2,329-square-foot, single-family residence and attached 397-square-
foot, two-car garage in the R-BI Zoning District.
PUBLIC NOTICE
Notice of this public hearing was published in the Daily Pilot, mailed to all owners and
residential occupants of property within 300 feet of the boundaries of the site (excluding
intervening rights-of-way and waterways), including the applicant, and posted on the
subject property at least 10 days before the scheduled hearing, consistent with the
provisions of the NBMC. Additionally, the item appeared on the agenda for this meeting,
which was posted at City Hall and on the City website.
APPEAL PERIOD:
This action shall become final and effective 14 days following the date the Resolution is
adopted unless within such time an appeal or call for review is filed with the Community
Development Director in accordance with the provisions of Title 21 (Local Coastal
Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City
may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the
City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through
13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal,
contact the Planning Division at 949-644-3200.
4
Bakshi Residence
Zoning Administrator, May 10, 2018
Page 5
Prepared by:
_____________________
Liane Schuller
Contract Planner
RU/ls
Attachments: ZA 1 Draft Resolution
ZA 2 Vicinity Map
ZA 3 Project Plans
5
Attachment No. ZA 1
Draft Resolution
6
RESOLUTION NO. ZA2018-###
A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE
CITY OF NEWPORT BEACH, CALIFORNIA APPROVING
COASTAL DEVELOPMENT PERMIT NO. CD2018-022 TO
DEMOLISH AN EXISTING RESIDENTIAL DUPLEX AND
CONSTRUCT A NEW THREE-STORY, SINGLE-FAMILY
RESIDENCE WITH AN ATTACHED TWO-CAR GARAGE AT 127
JADE AVENUE (PA2018-057)
THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS
FOLLOWS:
SECTION 1. STATEMENT OF FACTS.
1. An application was filed by Brandon Architects, Inc. (“Applicant”), on behalf of Bob Bakshi
(“Owner”), with respect to property located at 127 Jade Avenue, requesting approval of a
coastal development permit (“CDP”).
2. The property is legally described as Lot 16, in Block 3 of Tract 103, in the City of Newport
Beach, County of Orange, State of California.
3. The Applicant proposes to demolish an existing residential duplex, and construct a new
three-story, 2,329-square-foot, single-family residence and attached 397-square-foot, two-
car garage. The project will include hardscape, landscape, and subsurface drainage
facilities all located within the confines of private property. The design complies with all
applicable development standards and no deviations are requested.
4. The subject property is designated RT (Two-Unit Residential) by the General Plan Land
Use Element and is located within the R-BI (Balboa Island) Zoning District.
5. The subject property is located within the coastal zone. The Coastal Land Use Plan
category is RT-E (Two-Unit Residential - 30.0 – 39.9 DU/AC) and the property is located
within the R-BI (Balboa Island) Coastal Zone District.
6. A public hearing was held on May 10, 2018, in the Corona del Mar Conference Room (Bay
E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place, and
purpose of the hearing was given in accordance with the Newport Beach Municipal
Code. Evidence, both written and oral, was prese nted to, and considered by, the Zoning
Administrator at this hearing.
SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION.
1. This project is categorically exempt pursuant to Title 14 of the California Code of
Regulations Section 15303, Article 19 of Chapter 3, Guidelines for Implementation of the
California Environmental Quality Act (“CEQA”) under Class 3 (New Construction or
Conversion of Small Structures), because it has no potential to have a significant effect on
the environment.
7
Zoning Administrator Resolution No. ZA2018-###
Page 2 of 7
2. Class 3 exempts the construction and location of limited numbers of new, small facilities
or structures including one single-family residence in a residential zone. The proposed
project consists of the demolition of an existing residential duplex, and the construction
of a new 2,329-square-foot single-family residence and 397-square-foot, two-car garage
in the R-BI Zoning District.
SECTION 3. REQUIRED FINDINGS.
In accordance with Newport Beach Municipal Code (“NBMC”) Section 21.52.015 (Coastal
Development Permits, Findings and Decision), the following findings and facts in support of
such findings are set forth:
Finding:
A. Conforms to all applicable sections of the certified Local Coastal Program.
Facts in Support of Finding:
1. The proposed development complies with applicable residential development standards
including, but not limited to, floor area limitation, setbacks, height, and parking.
A. The total proposed floor area, including the residence and enclosed parking, is
2,726 square feet, which complies with the maximum allowable floor area limit of
2,726 square feet.
B. The proposed development will provide the minimum required setbacks, which are
ten (10) feet along the front property line abutting Jade Street, three (3) feet along
each side property line, and five (5) feet along the rear property line abutting the
alley.
C. The highest guardrail is no more than 24 feet and the highest roof ridge is no more
than 29 feet, measured from the established grade level of 9 feet based on the
North American Vertical Datum of 1988 (“NAVD88”), which complies with the
maximum height limitation.
D. The project includes enclosed garage parking for two vehicles, in compliance with
the minimum parking requirement for single-family residences with less than 4,000
square feet of habitable floor area.
2. The neighborhood is predominantly developed with two- and three-story single- and two-
family residences. The proposed design, bulk, and scale of the development is
consistent with the existing neighborhood pattern of development and expected future
development because the development meets all development standards for the
construction of a single-family residence.
3. The project site is located approximately 140 feet from the bay front and is separated from
the water by Jade Avenue, East Bay Front alleyway, a row of existing residential
8
Zoning Administrator Resolution No. ZA2018-###
Page 3 of 7
development and the Bay Front promenade. The finished first floor elevation of the
interior living area of the proposed residence is 9.00 feet based on the North American
Vertical Datum of 1988 (NAVD88) elevation standard, which complies with the minimum
required 9-foot (NAVD88) elevation standard. The finished floor elevation of the garage
(i.e., not living area) is 7.86 feet (NAVD88) with an approximately 2-percent slope
driveway connecting to the existing street.
4. The property is located in an area known for the potential of seismic activity and
liquefaction. All projects are required to comply with the California Building Code (CBC)
and Building Division standards and policies. Geotechnical investigations specifically
addressing liquefaction are required to be reviewed and approved prior to the issuance of
building permits. Permit issuance is also contingent on the inclusion of design mitigation
identified in the investigations. Construction plans are reviewed for compliance with
approved investigations and CBC prior to building permit issuance.
5. The project design addresses water quality with a construction erosion control plan that
outlines temporary Best Management Practices (BMPs) to be implemented during
construction to minimize erosion and sedimentation, and to minimize pollution of runoff
derived by construction chemicals and materials. No water quality impacts to coastal
waters are anticipated based upon the location and elevation of the property.
6. The property is not located on the shoreline nor is it located within 100 feet of coastal
waters. The project design addresses water quality with a construction erosion control plan
and a post construction drainage system that includes drainage and percolation features
designed to retain dry weather and minor rain event run-off on-site. Any water not retained
on-site is directed to the City’s storm drain system.
7. New landscaping will be verified for compliance with NBMC Section 21.30.075
(Landscaping). Condition of Approval No. 11 is included to require drought-tolerant, and
prohibits invasive, species. Prior to issuance of the building permits, the final landscape
plans will be reviewed to verify invasive species are not planted.
8. The property is not located near designated public viewpoints or coastal view roads and
will not impact public coastal views.
Finding:
B. Conforms with the public access and public recreation policies of Chapter 3 of the
Coastal Act if the project is located between the nearest public road and the sea or
shoreline of any body of water located within the coastal zone .
Fact in Support of Finding:
1. The project site is an inland lot on Balboa Island, and is located between the nearest public
road and the sea or shoreline. The existing residential development neither provides nor
inhibits public coastal access. Implementation Plan Section 21.30A.040 (Determination of
Public Access/Recreation Impacts) requires that the provision of public access bear a
reasonable relationship between the requirement and the project’s impact and be
9
Zoning Administrator Resolution No. ZA2018-###
Page 4 of 7
proportional to the impact. In this case, the project replaces an existing residential duplex
with a new single-family residence. Therefore, the project does not involve a change in
land use, density or intensity that will result in increased demand on public access and
recreation opportunities. Furthermore, the project is designed and sited so as not to block
or impede existing public access opportunities.
2. The residential lot does not currently provide nor does it inhibit public coastal access.
Lateral access is provided by the nearby bay front public sidewalk and public beach.
Vertical access to the bay front area is provided at various public street-ends throughout
Balboa Island, with the nearest vertical access provided along Park Avenue immediately
north of the project site.
3. The project site is not located adjacent to a coastal view road, public viewpoint, public park
or beach, or public accessway, as identified in the Coastal Land Use Plan. Furthermore,
an investigation of the project site and surrounding area did not identify any other public
view opportunities. The project site may be located within the viewshed of distant public
viewing areas. However, the project will replace an existing residential duplex with a new
single-family residence that complies with all applicable Local Coastal Program
development standards and maintains a building envelope consistent with the existing
neighborhood pattern of development. Therefore, the project does not have the potential
to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to
public views.
SECTION 4. DECISION.
NOW, THEREFORE, BE IT RESOLVED:
1. The Zoning Administrator of the City of Newport Beach hereby approves Coastal
Development Permit No. CD2018-022, subject to the conditions set forth in Exhibit “A,”
which is attached hereto and incorporated by reference.
2. This action shall become final and effective 14 days following the date this Resolution
was adopted unless within such time an appeal or call for review is filed with the
Community Development Director in accordance with the provisions of Title 21 Local
Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken
by the City may be appealed to the Coastal Commission in compliance with Section
21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations,
Sections 13111 through 13120, and Section 30603 of the Coastal Act.
PASSED, APPROVED, AND ADOPTED THIS 10TH DAY OF MAY, 2018.
_____________________________________
Patrick J. Alford, Zoning Administrator
10
Zoning Administrator Resolution No. ZA2018-###
Page 5 of 7
EXHIBIT “A”
CONDITIONS OF APPROVAL
1. The development shall be in substantial conformance with the approved site plan, floor
plans and building elevations stamped and dated with the date of this approval (except as
modified by applicable conditions of approval).
2. Revisions to the approved plans may require an amendment to this Coastal
Development Permit or the processing of a new coastal developme nt permit.
3. Coastal Development Permit No. CD2018-022 shall expire unless exercised within 24
months from the date of approval as specified in NBMC Section 21.54.060 (Time Limits
and Extensions), unless an extension is otherwise granted.
4. The project is subject to all applicable City ordinances, policies, and standards, unless
specifically waived or modified by the conditions of approval.
5. The Applicant shall comply with all federal, state, and local laws. Material violation of
any of those laws in connection with the use may be cause for revocation of this Coastal
Development Permit.
6. This Coastal Development Permit may be modified or revoked by the Zoning
Administrator if determined that the proposed uses or conditions under which it is being
operated or maintained is detrimental to the public health, welfare or materially injurious
to property or improvements in the vicinity or if the property is operated or maintained
so as to constitute a public nuisance.
7. Best Management Practices (BMPs) and Good Housekeeping Practices (GHPs) shall
be implemented prior to and throughout the duration of construction activity as
designated in the Construction Pollution Prevention Plan (CPPP).
8. Prior to issuance of a building permit, a copy of the Resolution, including conditions of
approval Exhibit “A” shall be incorporated into the Building Division and field sets of
plans.
9. Prior to issuance of a building permit, the Applicant shall submit to the Planning Division
an additional copy of the approved architectural plans for inclusion in the Coastal
Development Permit file. The plans shall be identical to those approved by all City
departments for building permit issuance. The approved copy shall include architectural
sheets only and shall be reduced in size to 11 inche s by 17 inches. The plans shall
accurately depict the elements approved by this Coastal Development Permit.
10. Prior to issuance of a building permit, the applicant shall submit a final construction
erosion control plan. The plan shall be subject to review and approval by the Building
Division..
11
Zoning Administrator Resolution No. ZA2018-###
Page 6 of 7
11. Prior to the issuance of a building permit, the Applicant shall submit a final landscape
and irrigation plan. These plans shall incorporate drought tolerant plantings, non-
invasive plant species, and water efficient irrigation design. The plans shall be approved
by the Planning Division.
12. All landscape materials and irrigation systems shall be maintained in accordance with
the approved landscape plan. All landscaped areas shall be maintained in a healthy and
growing condition and shall receive regular pruning, fertilizing, mowing, and trimming.
All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall
be kept operable, including adjustments, replacements, repairs, and cleaning as part of
regular maintenance.
13. Prior to the issuance of a building permit, the Applicant shall pay any unpaid
administrative costs associated with the processing of this application to the Plann ing
Division.
14. No demolition or construction materials, equipment debris, or waste, shall be placed or
stored in a location that would enter sensitive habitat, receiving waters, or a storm drain
or result in impacts to environmentally sensitive habitat areas, streams, wetland or their
buffers.
15. The discharge of any hazardous materials into storm sewer systems or receiving waters
shall be prohibited. Machinery and equipment shall be maintained and washed in
confined areas specifically designed to control runoff. A designa ted fueling and vehicle
maintenance area with appropriate berms and protection to prevent spillage shall be
provided as far away from storm drain systems or receiving waters as possible.
16. Debris from demolition shall be removed from work areas each day and removed from
the project site within 24 hours of the completion of the project. Stock piles and
construction materials shall be covered, enclosed on all sites, not stored in contact with
the soil, and located as far away as possible from drain inlets and any waterway.
17. Trash and debris shall be disposed in proper trash and recycling receptacles at the end
of each construction day. Solid waste, including excess concrete, shall be disposed in
adequate disposal facilities at a legal disposal site or recycled at a recycling facility.
18. Should the property be sold or otherwise come under different ownership, any future
owners or assignees shall be notified of the conditions of this approval by the current
property owner or agent.
19. To the fullest extent permitted by law, Applicant shall indemnify, defend and hold harmless
City, its City Council, its boards and commissions, officials, officers, employees, and agents
from and against any and all claims, demands, obligations, damages, actions, causes of
action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including
without limitation, attorney’s fees, disbursements and court costs) of every kind and nature
whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s
approval of Bakshi Residence including, but not limited to, Coastal Development Permit
No. CD2018-022 (PA2018-057). This indemnification shall include, but not be limited to,
12
Zoning Administrator Resolution No. ZA2018-###
Page 7 of 7
damages awarded against the City, if any, costs of suit, attorneys' fees, and other
expenses incurred in connection with such claim, action, causes of action, suit or
proceeding whether incurred by Applicant, City, and/or the parties initiating or bringing such
proceeding. The Applicant shall indemnify the City for all of City's costs, attorneys' fees,
and damages, which City incurs in enforcing the indemnification provisions set forth in this
condition. The Applicant shall pay to the City upon demand any amount owed to the City
pursuant to the indemnification requirements prescribed in this condition.
13
Attachment No. ZA 2
Vicinity Map
14
VICINITY MAP
Coastal Development Permit No. CD2018-022
PA2018-057
127 Jade Avenue
Subject Property
15
Attachment No. ZA 3
Project Plans
16
Name
Elevation
A101
1
SIM
Room name
150 SF
101
1i
?
90 00' 00"DistanceNE
1
1
A101
SIM
R @ 7 1/2"20
1i
NORTH ARROW
PROPERTY LINE TAG
SECTION INDICATOR
ROOM TAG (NAME / AREA)
CALL-OUT TAG
ELEVATION INDICATOR
KEYNOTE TAG
WINDOW TAG
DOOR TAG
WALL TAG
REVISION FLAG
STAIR TAG (NO. OF RISER & HEIGHT)
ALUMINUM
CONCRETE
EARTH
GYPSUM - PLASTER
INSULATION - RIGID
MASONRY - BRICK/STONE
MASONRY - CONCRETE BLOCK
PLYWOOD / GLU-LAM TIMBER
SAND
STEEL
WOOD
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.T-1.0
2/05/2018
127-2018TITLE SHEETBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.T-1.0
2/05/2018
127-2018TITLE SHEETBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662REF. 8/T-1.0FLOOR AREA
HEIGHT
NBMC (NEWPORT BEACH MUNICIPAL CODE)
CALIFORNIA CODES: 2016 CBC, 2016 CRC, 2016 CFC,
2016 CEC, 2016 CPC, AND 2016 CMC, 2016 CAL GREEN
R-3 / U
1-HR.
CODES:
OCCUPANCY CLASSIFICATION
OCCUPANCY SEPARATIONS (GARAGE)
OCCUPANT LOAD
TYPE OF CONSTRUCTION
OWNER: ARCHITECT:
N/AALLOWABLE BLDG. AREA
(PER CBC TBL. 503)
FLOOR & FLOOR-CEILINGS N/A
BRANDON ARCHITECTS, INC.
151 KALMUS DR. STE. G-1
COSTA MESA, CA 92626
P: 714.754.4040
WWW.BRANDONARCHITECTS.COM
STRUCTURAL ENGINEER:CIVIL ENGINEER:
GENERAL CONTRACTOR:LANDSCAPE DESIGNER:
SURVEYOR:SOILS ENGINEER:
SITE
~17
V-B - SPRK'R.
3 STORY
FIRE SPRINKLER: NFPA 13D YES
DEFERRED SUBMITTALS
8PROJECT STATISTICS 5 3 1
249
10
AGENCIES & PUBLIC SERVICES
VICINITY MAP/ PROJECT DESCRIPTION
MATERIAL LEGEND
ANNOTATION LEGEND CODE REVIEW SHEET LISTSITE INFORMATION11
7
6SPECIAL INSPECTIONS
PROJECT DIRECTORYPROJECT DIRECTORY
PROJECT DESCRIPTION:
BAKSHI RESIDENCE
BRANDON ARCHITECTS, INC.BOB BAKSHI
127 JADE AVE.
NEWPORT BEACH, CA 92662
TBD TBD
BUILDING AREA SCHEDULE
Name AREA COMMENTS
FIRST FLOOR LIVING 939 SF
SECOND FLOOR LIVING 1273 SF
THIRD FLOOR LANDING 116 SF
2329 SF
2-CAR GARAGE 397 SF
397 SF
GRAND TOTAL 2726 SF
OUTDOOR AREA SCHEDULE
NAME AREA COMMENTS
PATIO 448 SF (UNCOVERED)
BALCONY 38 SF (COVERED)
MASTER BALCONY 180 SF (COVERED)
ROOF DECK 467 SF (UNCOVERED)
DECK 142 SF (UNCOVERED)
CABANA 1 260 SF (COVERED)
CABANA 2 177 SF (COVERED)
Grand total 1712 SF
TBD
EGA CONSULTANTS, LLC.
375-C MONTE VISTA AVE.
COSTA MESA, CA 92627
P.949.642.9303
TBD
SHEET #DRAWING TITLE
T-1.0 TITLE SHEET
T-1.1 GENERAL ARCHITECTURAL NOTES
T-1.2 SUPPLEMENTAL NOTES & DOCUMENTS
SUR TOPOGRAPHIC SURVEY
A-0.0 ARCHITECTURAL SITE PLAN
C2 PRECISE GRADING PLAN
C4 EROSION CONTROL PLAN
A-1.0 3-DIMENSIONAL VIEWS
A-2.0 FLOOR PLAN
A-3.0 ROOF PLAN
A-4.0 EXTERIOR ELEVATIONS & MATERIAL SCHEDULE
A-4.1 EXTERIOR ELEVATIONS
A-5.0 BUILDING SECTIONS
A-5.1 BUILDING SECTIONS
INTERIOR DESIGNER:
TBD
DIG ALERT: 1.800.227.2600
SOUTHERN CALIFORNIA EDISON: 1.714.895.0246
SOUTHERN CALIFORNIA GAS: 1.800.427.2000
CITY WATER & SEWER: 1.949.644.3011
PACIFIC BELL TELEPHONE: 1.800.750.2355
CITY OF NEWPORT BEACH
PUBLIC WORKS DEPT.: 1.949.644.3311
CITY OF NEWPORT BEACH PLANNING DEPT.:
GENERAL INFOMATION: 1.949.644.3200
ZONING INFORMATION:1.949.644.3204
CITY OF NEWPORT BEACH BUILDING DEPT.:
GENERAL:1.949.644.3275
PERMITS:1.949.644.3288
INSPECTIONS:1.949.644.3255
NEWPORT BEACH FIRE DEPARTMENT:1.949.644.3106
ORANGE COUNTY HEALTH SERVICES:1.714.834.3882
NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR
ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL TO LOCAL AGENCY
FOR REVIEW.
C.N.B. NOTE:CHRISTOPHER BRANDON, ARCHITECT IS THE DESIGN
PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE FOR
REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS,
INCLUDING PHASED AND DEFERRED SUBMITTAL ITEMS, FOR COMPATIBILITY WITH
THE DESIGN OF THE BUILDING. (NBMC 15.02.010)
1.LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR
CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4 FT. HIGH FROM THE
BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPERATE
SUBMITTAL (FOR H.O.A. PURPOSES).
2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING
STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS.
3. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275.
SOUND LEVEL NOT TO EXCEED 50dBA (55dBA WITH TIMER, 65dBA WITH TIMER AND
NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT
PROPERTY PATIO OR OPENING.
4. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR
SHORING AND UNDERPINNING. CONTRACTOR TO PROVIDE A COPY OF OSHA
PERMIT.
5. FIRE SPRINKLERS REQUIRED, CONSTRACTOR TO SUBMIT FIRE SPRINKLER
DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO SUBMITTING TO CITY. OBTAIN
FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
1. REF. STRUCT. SHTS. FOR SPECIAL INSPECTION BY ENGINEER OF RECORD
2. HERS VERIFICATION REQUIRED, REF. T-24 ENERGY CALCULATIONS
LEGAL DESCRIPTION:
LOT INFORMATION:
1057 S.F. OPEN VOLUME PROVIDED
EXISTING BUILDING INFORMATION:
ZONING INFORMATION:
127 JADE AVE, NEWPORT BEACH, CA 92662
NO. REVISION DATENO. REVISION DATE
2,726 S.F. MAX
C
O
A
S
T H
W
Y E
BALBOA ISLAND
CHANNEL
PARK AVE
JADE AVEMARINE AVEAPN: 050 183 22
LOT 16, BLOCK 3, SECTION 5, BALBOA ISLAND,
CITY OF NEWPORT BEACH, COUNTY OF ORANGE, STATE OF CALIFORNIA
M.M. 8/9
ZONED: R-BI BALBOA ISLAND
SITE AREA:2,554 S.F. BUILDABLE AREA: 1,685 S.F.
TOTAL ALLOWABLE AREA: 1.5 x 1685 + 200 = 2,726 S.F.
OPEN VOLUME REQUIREMENT: .15 X 1685 = 252.6 S.F.
EXISTING SINGLE FAMILY W/ GARAGE TO BE DEMOLISHED
EXISTING S.F. = 2,171 S.F. (640 S.F.) GARAGE (5 BEDS. TTL.)
LOT COVERAGE (INCLUDING EAVES): 1,883.92 S.F.
PERCENTAGE OF LOT COVERAGE (PROPOSED): 73.8%
PERCENTAGE OF LOT COVERAGE (EXISTING): 58.3%
FRONT SETBACK: 10 FT.
REAR SETBACK: 5 FT.
LEFT SETBACK: 3 FT.
RIGHT SETBACK: 3 FT.
BUILDABLE AREA: 1,685 S.F.
APEX LAND SURVEYING, INC.
PAUL CRAFT, LIC. NO. 8516
HUNTINGTON BEACH, CA 92646
P: 714.488.5006
F: 714.333.4440
THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA ON BALBOA ISLAND. THE LOT IS
APPROXIMATELY 30’ WIDE BY 85’ DEEP, IT IS ZONED R-BI AND IS APPX. 2,554 S.F. THE PROPETY INCLUDES
AN EXISTING 2 STORY DUPLEX RESIDENCE TO BE DEMOLISHED. CLIENT PROPOSES TO BUILD A NEW 3
STORY SINGLE FAMILY RESIDENCE OF APPX. 2,329 S.F. INCLUDING AN ATTACHED 2-CAR GARAGE OF APPX.
397 S.F. TO BE WOOD FRAMED WITH A SLAB ON GRADE AND A ROOF-TOP VIEW DECK. THE PROJECT WILL
BE OF AN TRANSITIONAL EASTERN SEABOARD INSPIRED DESIGN, INCLUDING BUT NOT LIMITED TO THE
FOLLOWING: AMPLE INDOOR/OUTDOOR LIVING SPACES INTEGRATED WITH A MODERN ‘OPEN’ LIVING FLOOR
PLAN WHICH MAXIMIZES POTENTIAL VIEWS FROM LIVING SPACES. PARKING WILL BE PROVIDED IN THE
FORM OF A 2-CAR GARAGE. THE HOME WILL CONSISTING PRIMARILY OF HORIZONTAL WOOD SIDING AND
SOME USE OF STONE. THE HOME WILL HAVE (3) BEDROOMS, (4) FULL BATHS, (1) HALF BATH.
TOTAL LIVING
TOTAL GARAGE
BURKE STRUCTURAL ENGINEERS, PC
151 KALAMUS, BLDG. E-140
COSTA MESA, CA 92626
P:657.289.0460
BROOKE WAGNER DESIGN
2732 E. COAST HIGHWAY, STE. C
CORONA DEL MAR CA 92625
P:949.612.2716
TOM RUIZ
FORKETT ENGINEERING
22311 Brookhurst St,
Huntington Beach, CA 92646
P: 714 963 6793 Ext 234
MEP ENGINEERS:
GMEP ENGINEERS
26439 RANCHO PARKWAY S., STE #120
LAKE FOREST, CA 92630
P.949.267.9095
WATERPOINTE CUSTOM HOMES
610 NEWPORT CENTER DR.
SUITE 890
NEWPORT BEACH, CA 92660
P: 949.644.8900
17
18
UP
30' - 0"89° 59' 56"85.10'N E
89° 58' 45"85.10'N W
0° 00' 00"30.03'SW0° 00' 00"30.00'NEGREAT ROOMDININGKITCHEN
A/V.
ELEV.
ELEV. EQUIP.
PWDR.
PANTRY
2-CAR GARAGE
C.C.STAIRS
9.00' T.O.S.
9.00' T.O.S.
CLR.
18' - 3 7/8"CLR.20' - 2 1/8"WATER FEATURE
UPSLOPE PER CIVILFIRE PIT11.16'
11.16'
11.16'
11.16'
11.16'
11.16'
TOP OF STONEER WALL
UP
GATE
STONE VENEER WALL WITH FENCE ON TOP
CITY CORNER DEDICATION
R 10' - 0"10' - 0"10' - 0"
11.16'
HARDSCAPE
HARDSCAPE
PATIO
TOP OF STONE VENEER WALL
BBQ
HARDSCAPE HARDSCAPE
HARDSCAPE
HARDSCAPE
STEPS
RAMP 3' - 0"6' - 6"
8.83'10.92
WOOD FENCE
GATE2' - 10"CLR.
3' - 6"
TOP OF STONE VENEER LOW WALLTOP OF STONE
VENEER WALL
TOP OF STONE VENEER WALL SIDEWALKSIDEWALK
ALLEYDRIVEWAY
JADE AVE.PARK AVENUE
(E.) 7.66 FS
(E.) 7.71 FS
(E.) 7.75 FS
(E.) 7.68 FS
(E.) 7.67 FS
(E.) 7.8 FS
(E.) 7.75 NG
(E.) 7.73 FS(E.) 7.57 FS
13.57' T.W.13.57' T.W.13.57' T.W.
11.16' T.W.
11.16' T.W.
6' - 3 3/8"
CL. TO FACE OF CURB
13' - 8 5/8"
C.L. TO P.L.
5' - 0"21' - 9 7/8"8' - 1 3/8"29' - 11 1/8"F.O.F.5' - 0"5' - 1 1/2"F.O.F.3' - 0"3' - 0 1/2"F.Y.S.B.
10' - 0"
C.L. TO P.L.
20' - 0"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"5' - 0"
R.Y.S.B.
5' - 0"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.O.F.
5' - 0"
5' - 1 1/2"F.O.F.2' - 0"2' - 1 1/2"F.O.F.3' - 0"3' - 0 1/2"F.O.F.
10' - 0"
10' - 1 1/2"
15' - 5 3/4"
15' - 6 1/4"CLR.3' - 0"CLR.
3' - 0"3' - 7 1/2"F.O.F.3' - 2 3/4"3' - 4 1/4"F.O.F.2' - 11 7/8"3' - 0 3/8"F.O.F.6' - 6"6' - 6 1/2"F.O.F.3' - 2 3/4"3' - 3 1/4"13.42' T.O.F.F.O.F.9' - 4 5/8"9' - 5 1/8"13.42' T.W.F.O.F.1' - 1"F.O.F.1' - 1 1/8"F.O.F.1' - 11 7/8"F.O.F.1' - 6 1/8"13.42' T.O.F.
1 2
3
3
3
4
4
5 5
555
6
6
7
7
7
7
7
7
7 7
8
8
9
9
10
10
1010
11
12
12
12
12
12
12
12
12 13
13
TRASH AREA 14
21
15
15
1515
15
16
16
16
1616161617
11.16' T.O.F.
1
2
18
18
18
18
18
18
18
18
18
18
19
19
19 19
19
19
20
21
22
22
23 24
25
26
27
27
272828
292929
30
GATE 31 31
31
31 31
ENCROACHMENT PERMIT
AGREEMENT IS REQ'D. FOR ANY WORK
PROPOSED IN THE PUBLIC R.O.W. ALL NON-
STANDARD IMPROVEMENTS SHALL COMPLY
WITH CITY COUNCIL POLICY L-6 AND L-18
ENCROACHMENT PERMIT
AGREEMENT IS REQ'D. FOR
ANY WORK PROPOSED IN
THE PUBLIC R.O.W. ALL NON-
STANDARD IMPROVEMENTS
SHALL COMPLY WITH CITY
COUNCIL POLICY L-6 AND L-
18
21
32HARDSCAPE
(REF. CIVIL DWG.)
(REF. CIVIL DWG.)
(REF. CIVIL DWG.)
(REF. CIVIL DWG.)
6' - 2 7/8"13' - 9 1/8"
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.A-0.0
2/05/2018
127-2018ARCHITECTURAL SITE PLANBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.A-0.0
2/05/2018
127-2018ARCHITECTURAL SITE PLANBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662KEYNOTE LEGEND
1 DRAIN LINE - IN WALL/FROM ABV. (REF. CIVIL DWGS. & DETAILS)
2 OVERFLOW DRAINLINE- -IN WALL/ FROM ABOVE (TERMINATE ABV. EXT. FLATWORK
3 PROTECTIVE BOLLARD PER. STRUCT.
4 REAR YARD SETBACK
5 SIDE YARD SETBACK
6 FRONT YARD SETBACK
7 PROPERTY LINE
8 CENTERLINE OF STREET
9 CENTERLINE OF ALLEY
10 CURB
11 INTERIOR STAIRS/STEPS - REF. PLANS
12 HARDSCAPE - COLORED & SCORED CONCRETE (AS SELECTED) PER. LAND. ARCH.
13 CONCRETE STEPS ON GRADE - REF. CIVIL DWGS.
14 MAIN SERVICE PANEL, 400 AMP (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
15 EXISTING STRUCTURE - NOT A PART
16 (E.) SIDEWALK, CURB AND GUTTER PER C.N.B. STANDARDS - REF. CIVIL DWGS.
17 EXISTING DRIVEWAY APPROACH - REF. CIVIL DWGS. & LANDSCAPE DWGS.
18 OUTLINE OF EXISTING STRUCTURE TO BE REMOVED/DEMOLISHED
19 LINE OF ROOF ABOVE
20 (E.) GAS METER LOCATION (REF. SURVEY & CIVIL DWGS.)
21 (E.) SEWER M.H. (REF. SURVEY & CIVIL DWGS.)
22 (E.) WATER VALUE LOCATION (REF. SURVEY & CIVIL DWGS.)
23 (E.) SEWER C.O. LOCATION (REF. SURVEY & CIVIL DWGS.)
24 (E.) WATER METER LOCATION (REF. SURVEY & CIVIL DWGS.)
25 (E.) FIRE HYDRANT - PROTECT IN PLACE
26 PROVIDE GAS STUB-OUT FOR EXTERIOR FIRE-PIT PER OWNER
27 CMU WALL W/. STONE VENEER"
28 WOOD FENCE ABV. CMU WALL W/. STONE VENEER"
29 (N.) PROPERTY LINE WALL -CONCRETE FOOTING NOT TO EXCEED 6' MAX HT. ABV. NATRAL GRADE. - REF.
LANDSCAPE
30 TRASH LOCATION - SCREEN FROM STREET AS NEEDED
31 DOWNSPOUT - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. (ARCH. TO APPROVE)
32 BBQ, PROVIDED GAS STUB-OUT - G.C. TO COORD. W/. OWNER
TRUE NORTH
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE
(F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" - CONTACT ARCHITECT IN WRITING
FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
1/4" = 1'-0"1 ARCHITECTURAL SITE PLAN
PROJECT NORTH
LANDSCAPE NOTES:
1. ENCOARCHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANSCAPE PLAN, FOR ALL HARDSCAPE & PLANTING
AREAS WITH REPECTIVE HEIGHTS AND MATERIALS.
NOTE:
SEE SHEET A-3 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET
(INCLUDING EAVE DETAILS AND PROJECTION DISTANCES).
C.N.B. NOTES:
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT
RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS,
CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE
PROPERTY OR TO OBTAIN PLANS YOU SHOULD CONTACT YOUR COMMUNITY
ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED
BY THIS PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN
ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS
DEPARTMENT.
3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR
SHORING AND UNDERPINNING.
NO. REVISION DATENO. REVISION DATE
19
20
21
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.A-1.0
2/05/2018
127-20183-DIMENSIONAL VIEWSBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662NO. REVISION DATE
1 AXONOMETRIC - NORTHEAST 2 AXONOMETRIC - NORTHWEST
3 AXONOMETRIC - SOUTHEAST 4 AXONOMETRIC - SOUTHWEST
22
OVEN DW
T
UP
DWUP
NEW WALL - 2 x 6 STUDS @ 16" O.C.
NEW WALL - 2 x 4 STUDS @ 16" O.C.
WALL W/. STONE VENEER - 2 x 6 STUDS @ 16" O.C.
CONCRETE RETAINING WALL - REF. STRUCTURAL
CONCRETE MASONRY WALL - 6" CMU U.N.O.
DOUBLE WALL CONSTRUCTION - 2 x 4 MIN. STAGGERED
STUD @ 16" O.C.
WINDOW - REFERENCE SCHEDULE
DOOR - REFERENCE SCHEDULE
CABINET - BUILT IN CASEWORK
COLUMN -REF. STRUCTURAL DWGS.
FURNITURE - FOR PRESENTATION PURPOSES ONLY
FIREPLACE - PREFAB GAS-ONLY APPLIANCE
PLUMBING FIXTURE - SINK (AS SELECTED)
PLUMBING FIXTURE - TOILET (AS SELECTED)
PLAN LEGEND
LIGHTING FIXTURE - REFERENCE ELECTRICAL PLANS
FIRE RATED CEILING ASS'Y. REF. DTL. 7/AD-1
INT. FIRE RATED PARTITION REF. DTL. 7/AD-1
EXT. FIRE RATED PARTITION REF. DTL. 14/AD-1
101
1i
?KEYNOTE TAG - REFERENCE KEYNOTE LEGEND THIS SHT.
WINDOW TAG - REFERENCE SHEET A-7.0
DOOR TAG - REFERENCE SHEET A-7.0
1i WALL TAG - REFERENCE SHEET A-7.0
1.PROVIDE WHOLE BUILDING MECHANICAL
VENTILATION PER ASHRAE STANDARD 62.2-2016 SECTION
4, WITH EXCEPTION THAT NATURAL VENTILATION
THROUGH DOORS AND WINDOWS IS NOT AN
ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING
VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION 152
(a)). FOR CONTINUOUS WHOLE-BUILDING VENTILATION,
MIN. REQUIRED RATE OF VENTILATION IS 1 CFM FOR
EACH 100 S.F. OF CONDITIONED FLOOR AREA PLUS 7.5
CFM FOR EACH OCCUPANT (ONE OCCUPANT PER
BEDROOM +1). VENTILATION TO BE PROVIDED BY
EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND
SUPPLY AIR.
2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM
VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF
WHOLE-BUILDING VENTILATION REQUIREMENT).
MECHANICAL VENTILATION NOTE:
CALCULATIONS:
UNIT: 2,331 S.F.
(0.03)2,331 S.F.+ [7.5 CFM x OCC. (BED. +1)] =
69.93 CFM + (7.5 x 4) = 99.93 CFM REQ'D.
A-4.11
A-4.0
A-4.1
A-4.0
4
2
2
1
A-5.1
1
A-5.1
CLR.
18' - 3 7/8"CLR.4' - 6"CLR.
5' - 0"
2
A-5.0
2
A-5.0R 3'
-
8"CLR.19' - 10 1/8"3
A-5.0
3
A-5.0
2
A-5.1
2
A-5.1
4
A-5.0
4
A-5.0
3
A-5.1
3
A-5.1
1
A-5.0
1
A-5.0
2-CAR GARAGE
ELEV.
ELEV. EQUIP.
PWDR.
PANTRY
KITCHEN DINING GREAT ROOM
A/V.C.C.
STAIRS
5' - 1 1/2"69' - 10 1/4"10' - 1 1/2"
4
2
5
6
11
14
12
13 10 9 2
1 8
7 90.02°9
0
.
0
0
°89.98°3
1
1' - 8"16' - 6"1' - 10"2' - 5 7/8"2' - 3 3/8"2' - 2 1/8"3' - 0"3' - 0"2' - 5 5/8"4' - 5 7/8"2' - 4 1/2"3' - 5 3/8"
1' - 1 1/8"
11"5' - 2 7/8"11"10' - 6 1/2"3' - 1 3/4"2' - 3"
1' - 6 1/8"3' - 1 1/2"4' - 8 1/2"5' - 8 1/2"10' - 1"5' - 5 7/8"14' - 4 5/8"4' - 6"9"2' - 5 1/4"9' - 0 3/4"8' - 6"2' - 0 3/8"9"3' - 1 1/2"20' - 4 1/8"6' - 6 3/8"3' - 2 1/4"17' - 6 3/4"2' - 9 3/8"5' - 4 3/4"10' - 7 3/4"4' - 5 7/8"5' - 9 7/8"24' - 1 1/4"
3
5' - 1 1/2"21' - 3 3/8"3' - 7 1/2"3' - 1 1/4"CLR.
3' - 1 7/8"
18' - 10 5/8"5' - 10 3/4"13' - 9 3/8"8' - 8 3/8"17' - 2 1/4"5' - 4 3/4"2' - 3 7/8"11"5' - 1 1/2"69' - 10 1/4"10' - 1 1/2"
8' - 6 7/8"5' - 2 5/8"7' - 9"11 3/8"4' - 11 1/8"5 1/8"6' - 5"5' - 5"3' - 1 3/4"2' - 3"
8 1/4"1' - 9 5/8"2' - 10 7/8"1' - 4 1/8"1' - 10 7/8"7' - 4 3/4"2' - 0 1/8"2' - 5 3/4"2' - 4 1/2"3' - 11 3/8"1' - 0 1/8"2' - 10 5/8"2' - 4 1/4"11"2' - 3 1/8"4' - 1 3/4"4' - 1 3/4"2' - 5 5/8"1' - 8 5/8"2' - 6"2' - 4 3/4"2' - 1"5' - 10 1/8"5' - 6"3' - 10 7/8"4' - 10 3/4"1' - 1 5/8"5' - 6"3' - 10 5/8"4' - 0 5/8"2' - 7"1
1
2
3
4 3 5 6
7
8
2
3
9
210 311
12
CLR.
3' - 3 1/4"
R @ 0' - 7 3/4"15
13
14
15
15
15
15SLOPE PER CIVILSLOPE PER CIVIL7
AD-1
ABV.244.00°2' - 1 5/8"16
R 5' - 6"17
18
18
18
19
31
32
3' - 0 1/2"2' - 10 3/8"17' - 6 3/4"27
2 263
31 32
31 32
A-4.11
A-4.0
A-4.1
A-4.0
4
2
2
1
A-5.1
1
A-5.1
2
A-5.0
2
A-5.0
3
A-5.0
3
A-5.0
2
A-5.1
2
A-5.1
4
A-5.0
4
A-5.0
3
A-5.1
3
A-5.1
1
A-5.0
1
A-5.0
BEDROOM #3
BALCONY #3
STAIRS
ELEV.
LAUNDRY
DENJ.J. BATH
W.I.C.HERS
HIS
W.I.C.
MASTER SUITE MASTER
BALCONY
15
9 8
10
29
28
23
11 12 13
22
21
14 15 16
16
45
18
19
20
6
25
26
27
7
17
STEAM
SHWR.
SEAT
MECH.
SEATSEATSHWR.
HEATER ABV.
HEATER ABV.SEATSHWR.TUB
V.BUILT-INBUILT-IN
BUILT-INDRESSER
BUILT-IN BUILT-IN
24
5' - 0 1/2"47' - 10"22' - 2 1/8"10' - 0 1/2"
13' - 1"6' - 4 5/8"5' - 4 3/4"10' - 7 3/4"12' - 3 7/8"6' - 1 7/8"14' - 6 1/4"1' - 6"
10 7/8"3' - 0 5/8"2' - 6"2' - 6"3' - 3 1/2"10"1"3' - 5 1/2"2' - 10 5/8"6 7/8"6"4' - 3 3/8"2' - 2 1/8"3' - 0"3' - 0"2' - 5 5/8"4' - 5 7/8"1' - 6 1/8"1' - 11 1/2"3' - 5 1/2"
6 5/8"
4 3/8"
4 1/2"
2' - 1 3/4"2' - 8 5/8"11"7' - 5 5/8"3' - 1"3' - 0 3/4"11"7"11"7' - 7 5/8"6' - 0 5/8"2' - 4 1/4"11"3' - 3 1/4"13' - 8 1/4"6' - 8 7/8"3' - 0 1/2"23' - 8 3/8"3' - 3 1/2"2' - 1 1/2"24' - 7 3/8"3' - 3 1/8"3' - 3 1/4"20' - 5 1/8"11"11"1' - 11 1/8"17' - 7"2' - 4 1/4"11"5' - 0 1/2"64' - 6 1/2"5' - 5 3/4"10' - 0 1/2"
7' - 6 7/8"7' - 6 3/4"14' - 7 3/4"18' - 3 7/8"16' - 5 1/4"3' - 11 3/4"1' - 6"
3' - 6 5/8"4' - 0 1/8"1' - 8 1/8"8' - 9"1' - 11 5/8"2' - 3"7' - 0 3/4"7' - 7 1/2"3' - 7 5/8"2' - 3 1/4"2' - 4 1/8"6' - 5"2' - 4 1/8"3' - 1"3' - 0 3/4"11"7"11"
1
2
3
11 CLR.2' - 8"CLR.
3' - 9 1/2"
2
20 R 3' - 0 3/4"R 5' - 4 1/4"
1
1
21
211
10
10
11
2
3
22
23
2 3
23
10
2 3 24
FD
FLOOR DRAIN
27
2812
2% MIN.
2% MIN.2% MI
N.
2% MIN.2% MIN.2% MIN.2% MI
N.2% MIN.11 1/2"10 1/2"2' - 4 1/4"33 33
33
33
333432AD-1
11
32
34
15
35
35 35
CLR.
2' - 11 1/2"CLR.2' - 9 3/8"CLR.
5' - 0"CLR.4' - 6"2
FAU FAU
40
40
11"42
43
43
A-4.11
A-4.0
A-4.1
A-4.0
4
2
2
1
A-5.1
1
A-5.1
2
A-5.0
2
A-5.0
3
A-5.0
3
A-5.0
2
A-5.1
2
A-5.1
4
A-5.0
4
A-5.0
3
A-5.1
3
A-5.1
1
A-5.0
1
A-5.0
CABANA
ROOF DECK
ELEV.
CATWALK
STAIRS
MECH.
SERVINGBATH #4 VIEW DECK
18
19
20
21 22
31
30
34
32
24 25
33
17
357:127:12
7:12 7:127:127:12
7:12
SEATSHWR.
8' - 3 3/4"41' - 6 7/8"14' - 3 3/8"20' - 11 1/4"
21' - 7 1/8"5' - 7 1/4"14' - 4 1/2"7' - 10 3/8"6' - 5"7' - 7 1/2"
4' - 11 1/2"10' - 5 1/8"6' - 2 1/2"2' - 3 3/8"9' - 3 5/8"2' - 9 1/2"2' - 1 1/2"3' - 2 3/4"12' - 3 3/8"8' - 1 3/4"2' - 10 3/4"3' - 3"3' - 3"2' - 10 3/4"6' - 6 3/4"20' - 5 1/8"3' - 0 1/2"3' - 11 1/8"6' - 3 5/8"2' - 0 5/8"1' - 8 3/8"3' - 0 1/4"5' - 3 1/4"1' - 8 1/8"3' - 0 1/2"23' - 11 3/8"11' - 8"12' - 3 3/8"1' - 6 3/8"9' - 4 7/8"1' - 4 1/4"1' - 8 3/8"3' - 0 1/4"6' - 11 3/8"2' - 1 5/8"9' - 2 5/8"7' - 9 1/8"1' - 4 1/4"
24' - 0 1/8"21' - 0 3/8"40' - 0 5/8"
15' - 8 3/8"1' - 1 3/8"4' - 9 3/8"10' - 7 3/4"4' - 5 7/8"26' - 8 7/8"
2' - 2 1/8"3' - 0"3' - 0"2' - 5 5/8"R
3
' -
6
"R 5' - 6"20
25
2
6
5
26
10
2
11
24
27
R @ 0' - 7 1/2"15
12
28
29
2930
2
15
15
15
2% MI
N.
2% MIN.2% MIN.2 % M I N .
2 % M I N .2% M IN .2% MIN.2% MIN.2% MIN.2% MIN.
2 % M IN .SPA BY
SEP.
PERMIT
MUST REMAIN 100% OPEN MUST REMAIN 100% OPEN
MUST REMAIN 100% OPENTVBUILT-INS BUILT-INS
BENCH
36
36 36
36
37
37
28.67' T.O.S.
28.67' T.O.S.
28.45' T.O.S.
38 CLR.4' - 6"CLR.
5' - 0"2% MIN.2% MIN.2% MIN.39
2% MIN.2% MIN.2 % M I N .
2% MIN.CLR.2' - 6 1/8"CLR.
2' - 7 3/4"
33.00' T.R.
FAU
37
33.00' T.R.
31.96' T.R.
31.96' T.R.
23
41
30.82'
TOP OF FIREPLACE
43
43
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.A-2.0
2/05/2018
127-2018FLOOR PLANBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662STAIRWAY NOTE:
ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1
FOOT CANDLE PER CRC R303.7
KEYNOTE LEGEND
1 FURNISHINGS - AS SELECTED
2 COUNTERTOP - AS SELECTED
3 BASE CABINET - BUILT-IN, FINISH AS SEL.
4 REFRIGERATOR - VERIFY APPLIANCE W/. OWNER
5 LAUNDRY SINK - AS SEL.
6 DISHWASHER - AS SELECTED
7 RANGE - VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFGR.)
8 KITCHEN EXHAUST HOOD - PROVIDE MIN. RATE OF 100 CFM PER BEES 150(o), EXC. 5 TO 152(a) & ASHRAE STD.
62.2- INSTALL & PROVIDE POWER PER MFGR'S. INSTRS. - VENT TO EXTERIOR
9 DOUBLE OVEN - AS SELECTED
10 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO.
11 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)
12 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1
FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
13 UPPER CABINET - BUILT-IN, FINISH AS SEL.
14 1-3/8" MIN. SOLID CORE DOOR, SELF CLOSING & SELF LATCHING (R302.5.1)
15 1-1/2" MAX. STEP AT OUT SWING DOORS (R311.3.1)
16 ENCLOSED USEABLE SPACE UNDER STAIRWAY USE 5/8" TYPE 'X' GYP. BD. FINISH TYP. (1/2" MIN.) (CRC R302.7)
17 FIREPLACE- PREFABRICATED, GAS ONLY, ' ASTERIA' MODEL GEORGIAN 50" [DTL. 22/AD-1] (FACTORY BUILT
FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AN INSTALLED IN ACCORDANCE W/.
THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. DIRECT VENT GAS APPLIANCES MUST COMPLY W/. CAL
GREEN CODE REQUIREMENTS AND MUST COMPLY WITH ANSI Z21.50. GASEOUS FUEL BURNING PAN MUST BE
PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY
STANDARDS MANDATORY MEASURES.)
18 PROTECTIVE BOLLARD PER. STRUCT.
19 RESIDENTIAL ELEVATOR - 'CALIFORNIA CUSTOM LIFT, INC.' OR EQUIV., SHAFT SIZE = 54" X 60" CLEAR - PROVIDE
SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION
20 WATER HEATER - TANK-LESS (ON DEMAND-DIRECT VENT) WALL-MOUNT +44" MIN., 'NORITZ' OR EQUIV. - VERIFY
SIZE REQ'D. W/. MFGR. INSTALL PER MFGR. SPEC.
21 WASHER - PROVIDE HOOK-UPS & POWER
22 BATHTUB - AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
23 SHELF AND POLE - BUILT IN, FINISH AS SEL.
24 FIREPLACE - PREFABRICATED, GAS ONLY, 'DAVINCI' CUSTOM FIREPLACE (ANSI Z21.50B), FULL BAY
CONFIGURATIONS [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS SHALL
BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS.
GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY
W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
25 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATT. REQ'D.
BY C.N.B.) - UNITS TO BE SCREENED FROM VIEW W/. 42" HIGH FENCING PER C.N.B. REQ'TS. - UNIT TOP TO NOT
EXCEED HOA'S 14 FEET MAX HT.
26 PROVIDE POWER FOR BUILT-IN APPLIANCE/EQUIPMENT
27 INTERIOR STAIR MOUNTED RAILING - 34"-38" ABV. NOSING, REF. DTLS. 2, 8/AD-1
28 INTERIOR GUARDRAIL - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 4/AD-1
29 EXTERIOR GLASS GUARDRAIL W/. HANDRAIL- MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 2,4/AD-1
30 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT
31 DRAIN LINE - IN WALL/FROM ABV. (REF. CIVIL DWGS. & DETAILS)
32 OVERFLOW DRAINLINE- -IN WALL/ FROM ABOVE (TERMINATE ABV. EXT. FLATWORK
33 EXTERIOR GUARDRAIL - MIN. 42" HIGH - 4" MAX. SPHERE OPENING
34 DECK DRAIN - SLOPE 2% MIN. - REF. DTL. 11/AD-1
35 WINDOW TO MEET EGRESS REQ'TS. - REF. WINDOW NOTE #4 ON SCHEDULE
36 ZINC STANDING SEAM METAL ROOFING - COLOR AS SELECTED - REF. MAT. SCHED. A/A-4.0
37 ALUMINUM GUTTER - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO
ARCH.
38 STEP IN FLOOR/SLAB - 6" U.N.O.
39 WOOD SCREENING WALL FOR A/C. UNITS - (OWNER TO APPV. FINISH)
40 SHOWER - HOT-MOP PAN, PROVIDE TILE W/. CEMENT BACKING MIN. 70" HIGH; NET AREA 7.1 S.F. MIN.; 30" DIA.
CIRCLE MIN. (CPC 411.7)
41 PROVIDE GAS STUB-OUT FOR EXTERIOR FIRE-PIT PER OWNER
42 TRELLIS - ARCH. TO APPV. PROFILES
43 DECK WATERPROOFING PER MAT. SCHED. - A-4.0 INSTALL PER MFGR. SPEC'S
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE
(F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" - CONTACT ARCHITECT IN WRITING FOR
ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
1/4" = 1'-0"1 FIRST FLOOR PLAN
1/4" = 1'-0"2 SECOND FLOOR PLAN
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
A
ROUGH FRAMING:
ALL EXTERIOR WALL TO BE FRAMED WITH 2 X 6 STUDS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
NO. REVISION DATE
1/4" = 1'-0"3 THIRD FLOOR PLAN
TRUE NORTH PROJECT NORTH
23
UP
ROOF VENTILATION NOTES: (CRC R806)
1. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED
DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH
SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW.
VENTILATION OPENINGS SHALL HAVE AT LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS
HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED W/. CORROSION-RESISTANT WIRE
CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIM. OF
1/16" MIN. AND 1/4" MAX. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQ'TS. OF
CRC R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR.
2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE
VENTILATED. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE OR MORE OF
THE FOLLOWING ARE MET; 1. IN CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED
ON THE WARM-IN-WINTER SIDE OF THE CEILING. 2. AT LEAST 40% AND MORE THAN 50% OF THE
REQUIRED VENTILATING ARE IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE
ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE
RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF TEH
REQUIRED VANTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR
ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION
MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST OF THE SPACE SHALL BE PERMITTED.
3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW
OF AIR. A MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHT'G.
AND AT THE LOCATION OF THE VENT.
4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION INSTRUCTIONS.
INSTALLATION OF VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF
SECTION R903. INSTALLATION OF VENTILATORS IN WALL SYSTEMS SHALL BE IN ACCORDANCE W/. THE
REQ'TS. OF SECTION R703.1.
5. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY AND THE
ROOF RAFTERS) AND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES BETWEEN CEILINGS THAT
ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBER/RAFTERS AND THE
STRUCTURAL ROOF SHT'G. AT THE TOP OF THE ROOF FRAMING MEMBERS/RAFTERS) SHALL BE
PERMITTED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: 1. THE UNVENTED ATTIC SPACE IS
COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE. 2. NO INTERIOR CLASS I VAPOR
RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY
OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED RAFTER ASEEMBLY. 3. WHERE WOOD SHINGLES
OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES THE SHINGLES OR SHAKES AND THE
ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. 4. IN CALIFORNIA CLIMATE ZONES 14 & 16,
ANY AIR-IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR RETARDER, OR SHALL HAVE A CLASS III
VAPOR RETARDER COATING OR COVERING IN DIRECT CONTACT W/. THE UNDERSIDE OF THE INSULATION
(SEE TITLE 24, PART 6, FIG. 100.1-A) 5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE
AIR PERMEABILITY OF THE INSULATION DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO
INSULATION SHALL BE REQ'D. WHEN ROOF TILES, WOOD SHINGLES OR WOOD SHAKES, OR ANY OTHER
ROOFING SYSTEM USING BATTENS AND NO CONT. UNDERLAYMENT IS INSTALLED. A CONT. LAYER SHALL
BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR ANY CONT. LAYER WHICH HAS A PERM RATE OF
NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); 5.1. AIR-IMPERMEABLE INSULATION ONLY.
INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF
SHT'G. 5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION
INSTALLED DIRECTLY BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET INSULATION W/. AN R-
VALUE OR R-4 SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR
CONDENSATION CONTROL. 5.3. AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION. THE AIR-
IMPERMEABLE INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE
STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. THE AIR-PERMEABLE INSULATION SHALL BE
INSTALLED DIRECTLY UNDER TH AIR-PERMEABLE INSULATION. 5.4. WHERE PREFORMED INSULATION
BOARD IS USED AS THE AIR0IMPERMEABLE INSULATION LAYER, IT SHALL BE SEALED AT THE PERIMETER
OF EACH INDIVIDUAL SHEET INTERIOR SURFACE TO FORM A CONT. LAYER.
2x ROOF RAFTER
(PER STRUCT.)
INTERIOR FINISH
(PER PLANS, WHERE
OCCURS)
AIR-PERMEABLE
INSULATION
(PER PLANS)
MIN. 2 LAYERS 15#
ROOF FELT O/. CAP
SHT.
1/2" CDX PLYWD. SHT'G.
MIN. (REF. STRUCT)
SHINGLES TO BE NO. 1 GRADE WESTERN RED CEDAR W/. A MAX.
MOISTURE CONTENT OF 25%
FASTENERS PER NOTE #3
LENGTH TO BE
DETERMINED BY
UNDERLAYMENT LAYER,
REF. NOTE #5
(2) PER SHINGLE/SHAKE
12 SLOPE PER PLAN
(MIN. 4:12 SHAKES)
(MIN. 3:12 SHINGLES)
WOOD SHINGLE NOTES:
1.
SHINGLES TO BE INSTALLED ON SOLID SHT'G. IN ACCORDANCE
WITH CBC TABLE 1507.8
2.
FASTENERS MUST BE HOT-DIPPED GALVANIZED W/. ZINC COATING
WTS. IN ACC. W/. ASTM A 153, OR S.S.
3.
'FSR TREATMENT, INC.' CLASS 'A' ROOFING ASS'Y. ICC# ESR-1410
STARTER COURSES AT THE EAVE MUST BE DOUBLED, W/. FIRST
COURSE BEING FULL-SIZE TREATED SHINGLES, SUPPLIED BY
'CHEMCO, INC.' 15" OR 18" TREATED SHINGLES MAY BE USED FOR
THE FINAL COURSE AT THE RIDGE.
4.
PRODUCTS LISTED AS 'CLASS B' SHINGLES MUST BE INSTALLED O/.
SPACED OR SOLID SHT'G. COVERED EITHER W/. ONE LAYER OF 1-1/4"
DENS-DECK ROOF BOARD, MANUFACTURED BY GEORGIA PACIFIC
CORP., OR W/. ONE LAYER MINERAL-SURFACED CAP SHEET
COMPLYING W/. ASTM D 3909. WHERE UNDERLAYMENT IS REQ'D.,
THE UNDERLAYMENT SHALL BE INSTALLED OVER THE DENS-DECK
BOARD OR MINERAL-SURFACED CAP SHEET. FASTENER LENGTH
FOR THE SHAKES MUST BE INCREASED FOR THE THICKNESS OF THE
DENS-DECK BOARD OR CAP SHEET. THE DENS-DECK BOARDS MUST
BE FASTENED TO SPACED OR SOLID SHT'G. USING A MIN. OF FOUR
FASTENERS PER BOARD TO AVOID PANEL SHIFTING PRIOR TO
INSTALLATION OF THE SHAKES. THE MINERAL-SURFACED CAP
SHEET MUST BE INSTALLED WITH 2" OVERLAPS ON THE SIDES AND
ENDS, AND ATTACHED W/. A SUFFICIENT NUMBER OF FASTENERS TO
HOLD THE SHEET IN PLACE PRIOR TO INSTALLATION OF THE
SHAKES.
5.
MIN. CAP SHT. - REF.
NOTE #5 ABV.
EXPOSURE & OVERLAP PER
CBC TABLE 1507.8.6
AUTOMATIC SPRINKLERS TO BE INSTALLED THROUGHOUT & IN
ATTIC AREAS IN ACCORDANCE WITH C.N.B. STANDARDS (PROVIDE
SEPARATE APPLICATION, REF. 8/T-1)
6.
EAVES TO BOXED 1-HR. ASSEMBLY PER NBMC 15.04.2207.
UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
1. AT UNVENTED ENCLOSED RAFTER ASSEMBLY PROVIDE
1X SLEEPER OVER ROOF UNDERLAYMENT FOR MIN. 1/4"
VENTED AIR SPACE SEPARATE WOOD SHAKE OR
SHINGLE AND ROOFING UNDERLAYMENT TO MEET
REQUIREMENT OF THE SECTION R806.5 OF CBC
2. NO INTERIOR CLASS I VAPOR RETARDER SHALL BE
INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE
UNVENTED ATIIC ASSEMBLY OR ON THE CEILING SIDE OF
THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
THERMAL BATT INSUL'N.
EAVE FLASHING W/. DRIP (BY ROOFING
MFGR.) TO MATCH ROOF
CONT. WOOD FASCIA PAINT & SEAL -
VERIFY SIZE & FINISH W/. ARCH.
ROOFING MATERIAL, REF. PLANS
30# ROOF FELT MIN., TYP.
'TYVEK' OR EQ. BLDG. WRAP
PLYWD. SHT'G. (PER STRUCT'L.)
INTERIOR FINISH, PER PLAN
CAULK & SEAL
2x ROOF RAFTERS (REF. STRUCT'L.)
PLYWD. SHT'G. PER STRUCT.
SOLID 2x DBL. BLK'G.
2x T&G O/. BLDG. WRAP -
PAINT & SEAL.
EXTERIOR VENEER - REF. PLANS &
ELEVS.
KYNAR PAINTED ALUM. GUTTER- HALF
ROUND. COLOR TO MATCH ROOF
4x6 WOOD RAFTER-VERIFY
PROFILE W/. ARCH
FILLED REGION INDICATES ATTIC SPACE- REF. ATTIC
VENTILATION CALCS.
ROOF PLAN LEGEND
3x6 WD. FASCIA, AS SEL. BY
ARCH.
ROOFING PER PLAN & MAT. SCHED.
2X ROOF RAFTERS
ROOF SHT'G PER STRUCT.
INTERIOR FINISH PER PLANS
METAL DRIP EDGE, 1/4" MIN. (TYP.)
2X SOLID BLK'G., FOR CONDITIONS
WITHIN 5 FEET OF PROPERTY LINE
DOUBLE 2x SOLID BLK'G. IS REQUIRED
EXT. STUCCO FINISH - REF. ELEV.
& MAT. SCHED.
PLYWD. SHT'G. (PER STRUCT.)
TYVEK OR EQUIV. BLD'G. WRAP
4x6 STAIN GRADE OUTLOOKER
@ 30" O.C. (VERIFY W/. ARCH.)
2x6 T&G, DOUGLAS FIR OR EQUIV.1/2"3 1/2"REF. ROOF PLAN, SHT. A-5
OVERHANG
2X ROOF RAFTERS, REF. STRUCT.
FOR TRANSITION
A-4.11
A-4.0
A-4.1
A-4.0
4
2
2
1
A-5.1
1
A-5.1
2
A-5.0
2
A-5.0
3
A-5.0
3
A-5.0
2
A-5.1
2
A-5.1
4
A-5.0
4
A-5.0
3
A-5.1
3
A-5.1
1
A-5.0
1
A-5.07:127:12
7:12 3:123:123:123:123:123:12
3:123:123:12
3:123:12
3:12
3:12 7:127:12
7:127:1237.96'
37.96'
37.84'
37.84'
31.96'
33.00'
31.96'
HT. CERT. REQ'D.
HT. CERT. REQ'D.
HT. CERT. REQ'D.
HT. CERT. REQ'D.
HT. CERT. REQ'D.3:123:123:12
3:121' - 3 5/8"8' - 8 7/8"2' - 9 3/4"2 3/4"1' - 3 5/8"8' - 8 7/8"1' - 6 5/8"1' - 3 5/8"1' - 3 5/8"2' - 0"1' - 3 5/8"3' - 9"1' - 3 5/8"
3' - 9"1' - 3 5/8"2 3/4"2' - 9 3/4"1' - 8 5/8"38' - 4"6 1/4"4' - 6 1/8"39' - 9 7/8"8 1/4"2 3/4"34' - 11 7/8"2 3/4"2' - 9 3/4"2 3/4"2' - 9 3/4"8' - 1"2 3/4"2 3/4"23' - 9 3/8"2 3/4"2 3/4"5 3/4"5 3/4"ROOF PLATE ROOF PLATE
ROOF PLATEROOF PLATE
ROOF PLATE -1' - 0"
1' - 8 5/8"
ROOF PLATE -1' - 0"
THIRD FLOOR T.O.S.
THIRD FLOOR T.O.S.
THIRD FLOOR T.O.S.THIRD FLOOR T.O.S.THIRD FLOOR T.O.S.
THIRD FLOOR T.O.S.
ROOF PLATE +1' - 2"
REF. A-2/0
DECK
REF. A-2/0
1
1 1
1
1
1
1
2
3
4
3
4
4
4 4
4
VIEW DECK
ROOF DECK
4' - 8 5/8"5' - 3 3/4"2 1/4"1
2x ROOF RAFTER
(PER STRUCT.)
INTERIOR FINISH
(PER PLANS,
WHERE OCCURS)
AIR-PERMEABLE
INSULATION
(PER PLANS)
MIN. 30# ROOF FELT- (2)
LAYERS GAF
VERSASHIELD
UNDERLAYMENT
15/32" CDX PLYWD.
SHT'G.
MIN. (REF. STRUCT)
FASTENERS PER
MFGR. INSTRUCTIONS
12
SLOPE PER PLAN
STANDING SEAM METAL
(ZINC OR EQUIV.) - REF.
MAT. SCHED. A/A-5,
CLASS 'A' ASSY.
TYP.6" - 10"6" MIN.
DOUBLE FOLD
3/4" LOCK, ALT. METHOD
CLEATS @ 18" O.C. MAX.
CONT. LOCK STRIP,
SOLDERED
ARCH. TO APPV.
12"-16"1-1/2" HIGHVALLEY DETAIL
PRODUCT LISTING:
ICC # ESR-2048, CB-150
UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON
THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATIIC
ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED
ROOF FRAMING ASSEMBLY.
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.A-3.0
2/05/2018
127-2018ROOF PLANBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662KEYNOTE LEGEND
1 WOOD SHINGLE ROOFING PER MATERIAL SCHEDULE
2 CHIMNEY CAP/SPARK ARRESTOR - [DTL. 21/AD-1] (NOTE: DECORATIVE SHROUDS SHALL NOT BE
INSTALLED AT THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE
LISTED AND LABELED FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN
ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4)
3 ROOF FASCIA, KYNAR PAINTED ALUM. ACM PANELING (OLD COUNTRY MILLWORKS-CHAMPAGNE-GREY) -
EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS)
4 ALUMINUM GUTTER - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. - PROVIDE SHOP DWGS.
TO ARCH.
1 1/2" = 1'-0"2 WOOD SHINGLE ROOFING
1 1/2" = 1'-0"3 EAVE DETAIL
1" = 1'-0"4 RAKE DETAIL
NOTE: ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP.
U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF FINISH FASCIA
A
NO. REVISION DATE
TRUE NORTH PROJECT NORTH
1/4" = 1'-0"1 ROOF PLAN
1 1/2" = 1'-0"5 METAL ROOFING DETAIL
24
WINDOWS & DOORS:
CEMENT BASED WOOD SIDING:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER: ASSOCIATED BUILDING SUPPLY
ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA
92626
CONTACT: JOE YOUNAN
PHONE: 949-872-3319
FAX: 206-666-2150
EMAIL: JYOUNAN@ABSSOCAL.COM
WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT: CUSTOM COLLECTION
ADDRESS: 3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE: 541-885-7412 OR 800-535-3936
FAX: 541-884-3331
WEB: WWW.JELD-WEN.COM
BI-FOLD DOORS (AS OCCURS)
MANUFACTURER: LACANTINA DOORS, INC.
PRODUCT: CUSTOM BI-FOLD DOOR SYSTEM
ADDRESS: 3817 OCEAN RANCH BLVD., STE. 114, OCEANSIDE, CA 92056
PHONE: 760.298.5030
FAX: 760.734.1591
WEB: WWW.LACANTINADOORS.COM
ALUMINUM-WOOD LIFT-N-SLIDE DOORS
MANUFACTURER: PACIFIC ARCHITECTURAL MILLWORKS
PRODUCT: SLIDE & SEAL DOORS
ADDRESS: 1435 W. PIONEER ST. BREA, CA 92821
PHONE: 562.905.3200
FAX: 562.694.6794
WEB: WWW.PACMILLWORK.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER: WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
MANUFACTURER:
JAMES HARDIE BUILDING PRODUCTS, INC.
10901 ELM AVENUE
FONTANA, CA 92337
P: 909.356.6366
COLOR: PAINTED-DUNN EDWARDS: WHITE
APPLICATION: SHIPLAP 4"/
CODE: ICC# NER-405
GUTTERS:
GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
FLASHING & WEATHERSTRIPPING:
MATERIAL: METAL - COPPER/ALUM. PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
TUFFLEX POLYMERS
10880 POPLAR AVE.
FONTANA, CA
P: 909.349.2016
WWW.TUFFLEXPOLYMERS.COM
CODE: ICC # ESR-2505
PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING &
WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE
WATERPROOFING AREAS PRIOR TO INSTALLATION.
EXTERIOR STONE VENEER
SUPPLIER:
KRC ROCK, NATURAL STONE & BOULDER SUPPLY
700 N. TWIN OAKS VALLEY RD.
SAN MARCOS, CA 92069
P: 760.744.1036
STONE TYPE:TBD
COLOR: TBD
APPLICATION: TBD
THICKNESS: 1" - 1.5" NOMINAL
WEIGHT: <10 PSF.
METAL ROOFING: ( CLASS 'A' )
MANUFACTURER:
CUSTOM-BILT METALS
13940 MAGNOLIA AVE.
CHINO, CA 91710
P: 909.664.1500
PRODUCT: STANDING SEAM METAL ROOFING, CB-150 (NON-REFLECTIVE)
COLOR: TBD
NOTES: USE CONTINUOUS 16" PANS - VERIFY W/. ARCH. SIZE & LOC'N. OF SEAMS
(NO TRANSVERSE SEAMS) REF. DTL 1/A-4
WEIGHT: APPX. 2 PSF.
CODE: ICC # ESR-2048, CB-150
WOOD SHINGLE ROOFING:
PRODUCT:WOOD SHINGLE - FIRE TREATED
MFGR: FSR TREATMENT, INC. WWW.FIRESMARTROOFING.COM
COLOR:NATURAL
APPLICATION: CLOSED VALLEY W/. MITERED HIP CUTS, 16 GAUGE COPPER FLASHING,
STAGGERED COURSING (REF. DTL. 2/A-3)
CODE:CLASS A ASSEMBLY (ICC# ESR-1410)
WEIGHT:N/A
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'
THIRD FLOOR PLT.
27.58'
THIRD FLOOR PLT.
27.58'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
ROOF PLATE
35.67'
ROOF PLATE
35.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
VIEW DECK
29.36'
ROOF PLT. DECK
28.45'
ROOF PLT. DECK
28.45'
4 5
6
18
2
17
1
7
22 2125
158 9
4
13.42'
11.16'
PL.PL.
1
7 :1 2
7:12
3:123:1 2 3:12
22
1
33
3
4 ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.T.O.C.8' - 3"9' - 3"1' - 1"8' - 3"1' - 1"7' - 0"9' - 3"1' - 1"9' - 1 3/8"11"6' - 3 5/8"10' - 4"9' - 1 3/8"10' - 4"10' - 0 3/8"24' - 0"29' - 0"T.O.C.8' - 9"T.O.C.8' - 9"T.O.C.8' - 3"SILL HT.3' - 6"SILL HT.3' - 6"SILL. HT.4' - 2"SILL HT.4' - 2"1' - 3"SILL HT.7' - 10"5
6
7
8
7
37.96'37.96'
33.00'
31.96'
HT. CERT. REQ'D.
HT. CERT. REQ'D.HT. CERT. REQ'D.
HT. CERT. REQ'D.
12
37.96'
HT. CERT. REQ'D.
5 5
5
14
15
15
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'
THIRD FLOOR PLT.
27.58'
THIRD FLOOR PLT.
27.58'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
ROOF PLATE
35.67'
ROOF PLATE
35.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
VIEW DECK
29.36'
ROOF PLT. DECK
28.45'3' - 0"PL.PL.
1615
14
25242221
11
12 13
3
6
7:127:1 2 6' - 3 5/8"11"9' - 1 3/8"1' - 1"9' - 3"7' - 0"1' - 1"8' - 3"1' - 1"9' - 3"9' - 4"10' - 4"10' - 0 3/8"10' - 4"29' - 0"24' - 0"SILL HT.3' - 0"SILL HT.5' - 0"SILL HT.3' - 0"SILL HT.5' - 0"SILL HT.4' - 2"SILL HT.4' - 2"SILL HT.3' - 6"1 1
344
9
7
8
106
37.96'
33.00'
HT. CERT. REQ'D.
HT. CERT. REQ'D.T.O.C.8' - 9"T.O.C.8' - 3"6' - 8"ABV. F.F42" MIN.11 9' - 4"10' - 4"1' - 1"8' - 3"1' - 1"9' - 3"3 :1 2 3:12
13
ABV. F.F.42" MIN.11
11
12
14
33
3 3 3
3
4
5 5 5
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.A-4.0
2/05/2018
127-2018EXTERIOR ELEVATIONS &MATERIAL SCHEDULEBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662KEYNOTE LEGEND
1 WOOD SHINGLE ROOFING PER MATERIAL SCHEDULE
2 ZINC STANDING SEAM METAL ROOFING - COLOR AS SELECTED - REF. MAT. SCHED. A/A-4.0
3 4" WOOD SIDING SHIPLAP - PER MAT. SCHEDULE"
4 STONE VENEER COLUMN - REF. DTL. 8/AD-1 & REF. MAT. SCHED. A/A-4.0
5 BOARD & BATTEN WOOD SIDING - REF. MAT. SCHED. A/A-4.0
6 DOWNSPOUT - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. (ARCH. TO APPROVE)
7 ALUMINUM GUTTER - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO
ARCH.
8 CHIMNEY CAP/SPARK ARRESTOR - [DTL. 21/AD-1] (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT
THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED
FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST.
INSTRUCTIONS. CMC 802.4.2.4)
9 ROOF FASCIA, KYNAR PAINTED ALUM. ACM PANELING (OLD COUNTRY MILLWORKS-CHAMPAGNE-GREY) - EAVE
AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS)
10 MAIN SERVICE PANEL, 400 AMP (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
11 DECO. WOOD TRIM 'BELLYBAND' - PAINT GRADE, SMOOTH FINISH, ARCH. TO APPROVE PROFILE
12 TEMPERED GLASS - 1/2" THK. (MIN. 3/8") ARCH. TO APPROVE PANEL SIZE & HARDWARE
13 EXTERIOR GUARDRAIL - MIN. 42" HIGH - 4" MAX. SPHERE OPENING
14 DECO. WD. PANELING - PAINT GRADE - COLOR AS SEL.
15 DECO. WOOD WINDOW SHUTTERS
MATERIAL SCHEDULEA
1/4" = 1'-0"4 RIGHT ELEVATION
1/4" = 1'-0"2 LEFT ELEVATION
NOTE: REF. ROOF PLAN (A-3.0) FOR ALL PLATE HTS. & RIDGE HTS.
NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT
LABELS.
NO. REVISION DATE
25
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'
THIRD FLOOR PLT.
27.58'
THIRD FLOOR PLT.
27.58'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
ROOF PLATE
35.67'
ROOF PLATE
35.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
30
18 19 20
10
2
5
PL PL
1
1
2
3
4 4
1
56
7
6
7
8
3 :1 2 3:12
3 :1 2 3:123:123:1 2
7 :1 2
7 :1 2 ABV. F.F.42" MIN.ABV. F.F.42" MIN.4
29' - 0"24' - 0"9' - 3"1' - 1"8' - 3"1' - 1"7' - 0"10' - 4"9' - 4"37.96'37.84'
31.96'
HT. CERT. REQ'D
HT. CERT. REQ'D HT. CERT. REQ'D
6
9
10
11
12
FIRST FLOOR (T.O.S.)
9.00'FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'29' - 0"GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'24' - 0"ROOF PLATE
35.67'
ROOF PLATE
35.67'
VIEW DECK
29.36'
VIEW DECK
29.36'
ROOF PLT. DECK
28.45'
ROOF PLT. DECK
28.45'
33
16
7
PLPL
9' - 3"1' - 1"9' - 1 3/8"7' - 2 5/8"10' - 4"10' - 0 3/8"T.O.C.8' - 3"3 :1 2 3:12
7:12
7:12
7
5
6
7
4
2
1
1
3
3
8
9
9
ABV. F.F.42" MIN.ABV. F.F.42" MIN.11
WINDOWS & DOORS:
CEMENT BASED WOOD SIDING:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER: ASSOCIATED BUILDING SUPPLY
ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA
92626
CONTACT: JOE YOUNAN
PHONE: 949-872-3319
FAX: 206-666-2150
EMAIL: JYOUNAN@ABSSOCAL.COM
WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT: CUSTOM COLLECTION
ADDRESS: 3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE: 541-885-7412 OR 800-535-3936
FAX: 541-884-3331
WEB: WWW.JELD-WEN.COM
BI-FOLD DOORS (AS OCCURS)
MANUFACTURER: LACANTINA DOORS, INC.
PRODUCT: CUSTOM BI-FOLD DOOR SYSTEM
ADDRESS: 3817 OCEAN RANCH BLVD., STE. 114, OCEANSIDE, CA 92056
PHONE: 760.298.5030
FAX: 760.734.1591
WEB: WWW.LACANTINADOORS.COM
ALUMINUM -WOOD LIFT-N-SLIDE DOORS
MANUFACTURER: PACIFIC ARCHITECTURAL MILLWORKS
PRODUCT: SLIDE & SEAL DOORS
ADDRESS: 1435 W. PIONEER ST. BREA, CA 92821
PHONE: 562.905.3200
FAX: 562.694.6794
WEB: WWW.PACMILLWORK.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER: WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
MANUFACTURER:
JAMES HARDIE BUILDING PRODUCTS, INC.
10901 ELM AVENUE
FONTANA, CA 92337
P: 909.356.6366
COLOR: PAINTED-DUNN EDWARDS: WHITE
APPLICATION: SHIPLAP 4"/
CODE: ICC# NER-405
GUTTERS:
GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
FLASHING & WEATHERSTRIPPING:
MATERIAL: METAL - COPPER/ALUM. PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
TUFFLEX POLYMERS
10880 POPLAR AVE.
FONTANA, CA
P: 909.349.2016
WWW.TUFFLEXPOLYMERS.COM
CODE: ICC # ESR-2505
PROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING &
WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE
WATERPROOFING AREAS PRIOR TO INSTALLATION.
EXTERIOR STONE VENEER
SUPPLIER:
KRC ROCK, NATURAL STONE & BOULDER SUPPLY
700 N. TWIN OAKS VALLEY RD.
SAN MARCOS, CA 92069
P: 760.744.1036
STONE TYPE:TBD
COLOR: TBD
APPLICATION: TBD
THICKNESS: 1" - 1.5" NOMINAL
WEIGHT: <10 PSF.
METAL ROOFING: ( CLASS 'A' )
MANUFACTURER:
CUSTOM-BILT METALS
13940 MAGNOLIA AVE.
CHINO, CA 91710
P: 909.664.1500
PRODUCT: STANDING SEAM METAL ROOFING, CB-150 (NON-REFLECTIVE)
COLOR: TBD
NOTES: USE CONTINUOUS 16" PANS - VERIFY W/. ARCH. SIZE & LOC'N. OF SEAMS
(NO TRANSVERSE SEAMS) REF. DTL 1/A-4
WEIGHT: APPX. 2 PSF.
CODE: ICC # ESR-2048, CB-150
WOOD SHINGLE ROOFING:
PRODUCT:WOOD SHINGLE - FIRE TREATED
MFGR: FSR TREATMENT, INC. WWW.FIRESMARTROOFING.COM
COLOR:NATURAL
APPLICATION: CLOSED VALLEY W/. MITERED HIP CUTS, 16 GAUGE COPPER FLASHING,
STAGGERED COURSING (REF. DTL. 2/A-3)
CODE:CLASS A ASSEMBLY (ICC# ESR-1410)
WEIGHT:N/A
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.A-4.1
2/05/2018
127-2018EXTERIOR ELEVATIONSBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662NO. REVISION DATE
1/4" = 1'-0"2 REAR ELEVATION
1/4" = 1'-0"1 FRONT ELEVATION
MATERIAL SCHEDULEA
NOTE: REF. ROOF PLAN (A-3.0) FOR ALL PLATE HTS. & RIDGE HTS.
NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT
LABELS.
KEYNOTE LEGEND
1
2 4" WOOD SIDING SHIPLAP - PER MAT. SCHEDULE"
3 4" WOOD SIDING SHIPLAP - PER MAT. SCHEDULE"
4 STONE VENEER COLUMN - REF. DTL. 8/AD-1 & REF. MAT. SCHED. A/A-4.0
5 DOWNSPOUT - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. (ARCH. TO APPROVE)
6 ALUMINUM GUTTER - KYNAR FINISH TO MATCH METAL ROOFING, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO
ARCH.
7 BOARD & BATTEN WOOD SIDING - REF. MAT. SCHED. A/A-4.0
8 CHIMNEY CAP/SPARK ARRESTOR - [DTL. 21/AD-1] (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT
THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED
FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST.
INSTRUCTIONS. CMC 802.4.2.4)
9 ROOF FASCIA, KYNAR PAINTED ALUM. ACM PANELING (OLD COUNTRY MILLWORKS-CHAMPAGNE-GREY) - EAVE AS
DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS)
10 PROTECTIVE BOLLARD PER. STRUCT.
11 EXTERIOR GUARDRAIL - MIN. 42" HIGH - 4" MAX. SPHERE OPENING
12 DECO. WOOD WINDOW SHUTTERS
26
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS
(BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A
TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES
AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE
MAINTAINED.
FIRE BLOCKS.
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING
FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY
ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR
OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE-
FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE
BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS.
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES.
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS
SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER
AREAS.
ATTICS.
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM
WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE
WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION.
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL
PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES
CONSTRUCTED AS REQUIRED FOR THE PARTITIONS.
FIRE-BLOCKING & DRAFT-STOP NOTE
INSULATION SCHEDULE:
EXTERIOR WALL:
2 x 4 CONST. = R-13 MIN.
2 x 6 CONST. OR LARGER =R-19
RAISED FLOOR:R-30 MIN.
ROOF:R-30
(REF. T-24 REPORT FOR MORE INFORMATION)
NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME
NEW WALL - 2 x 6 STUDS @ 16" O.C. U.N.O.
NEW WALL - 2 x 4 STUDS @ 16" O.C. U.N.O.
WALL W/. STONE VENEER - 2x STUDS @ 16" O.C. U.N.O.
CONCRETE RETAINING WALL - REF. STRUCTURAL
SEPARATION LEGEND
EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1
1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1
1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1
INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT.
B
FIRST FLOOR (T.O.S.)
9.00'FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'
THIRD FLOOR PLT.
27.58'
THIRD FLOOR PLT.
27.58'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
ROOF PLATE
35.67'
ROOF PLATE
35.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
1
A-5.1
2
A-5.1
3
A-5.1
KITCHEN
STAIRS
CATWALK
SERVING
W.I.C.
11 14
27
3091011
3 :1 2
3:12
12
13
146
7
10 7
P.L.P.L.
15
9' - 3"1' - 1"8' - 3"1' - 1"7' - 0"10' - 4"9' - 4"29' - 0"24' - 0"FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'
THIRD FLOOR PLT.
27.58'
THIRD FLOOR PLT.
27.58'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
ROOF PLATE
35.67'
ROOF PLATE
35.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
1
A-5.1
2
A-5.1
3
A-5.1
20 19 18
10
5
2
2-CAR GARAGE
BEDROOM #3
ROOF DECK
CABANA
MECH.
6
16
1
2 ABV. F.F.42" MIN.3 :1 2 3:12
7:12
ABV. F.F.42" MIN.5
P.L.P.L.29' - 0"24' - 0"10' - 4"9' - 4"9' - 3"1' - 1"8' - 3"1' - 1"7' - 0"8' - 3"5' - 11 3/4"8' - 6 1/2"FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'
THIRD FLOOR PLT.
27.58'
THIRD FLOOR PLT.
27.58'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
ROOF PLATE
35.67'
ROOF PLATE
35.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
1
A-5.1
2
A-5.1
3
A-5.1
CABANA
ROOF DECK ELEV.
ELEV.
ELEV.
ELEV. EQUIP.
KITCHENPWDR.PANTRY
DEN
23
20 19 18
27
14
3 :1 2 3:12 3 :1 2 3:12 3 :1 2 3:12
2
7
17187
P.L.P.L.10' - 4"9' - 4"9' - 3"1' - 1"8' - 3"1' - 1"7' - 0"29' - 0"24' - 0"FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
1
A-5.1
VIEW DECK
29.36'VIEW DECK
29.36'
ROOF PLT. DECK
28.45'
ROOF PLT. DECK
28.45'
2
A-5.1
3
A-5.1
16
7
MASTER SUITE
VIEW DECK
GREAT ROOM
1
2
3
4
ABV. F.F.42" MIN.ABV. F.F.42" MIN.7 :1 2
5
ABV. F.F.42" MIN.6
7
8
2
P.L.P.L.9' - 3"1' - 1"9' - 1 3/8"11"10' - 4"10' - 0 3/8"29' - 0"24' - 0"JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.A-5.0
2/05/2018
127-2018BUILDING SECTIONSBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662KEYNOTE LEGEND
1 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT
2 FURNISHINGS - AS SELECTED
3 TEMPERED GLASS ENCLOSURE - 1/2" THK. (MIN. 3/8" THK.) GLASS TO BE ETCH MARKED (FRAMELESS U.N.O.)
4 CHIMNEY CAP/SPARK ARRESTOR - [DTL. 21/AD-1] (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED
AT THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND
LABELED FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE
W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4)
5 EXTERIOR GUARDRAIL - MIN. 42" HIGH - 4" MAX. SPHERE OPENING
6 UPPER CABINET - BUILT-IN, FINISH AS SEL.
7 COUNTERTOP - AS SELECTED
8 BASE CABINET - BUILT-IN, FINISH AS SEL.
9 DISHWASHER - AS SELECTED
10 LAUNDRY SINK - AS SEL.
11 PROVIDE POWER FOR BUILT-IN APPLIANCE/EQUIPMENT
12 INTERIOR STAIR MOUNTED RAILING - 34"-38" ABV. NOSING, REF. DTLS. 2, 8/AD-1
13 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS
THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
14 KITCHEN EXHAUST HOOD - PROVIDE MIN. RATE OF 100 CFM PER BEES 150(o), EXC. 5 TO 152(a) & ASHRAE
STD. 62.2- INSTALL & PROVIDE POWER PER MFGR'S. INSTRS. - VENT TO EXTERIOR
15 WOOD SHINGLE ROOFING PER MATERIAL SCHEDULE
16 WATER HEATER - TANK-LESS (ON DEMAND-DIRECT VENT) WALL-MOUNT +44" MIN., 'NORITZ' OR EQUIV. -
VERIFY SIZE REQ'D. W/. MFGR. INSTALL PER MFGR. SPEC.
17 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO.
18 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)
NO. REVISION DATE
1/4" = 1'-0"2 TRANSVERSE SECTION
1/4" = 1'-0"3 TRANSVERSE SECTION
1/4" = 1'-0"4 TRANSVERSE SECTION
1/4" = 1'-0"1 TRANSVERSE SECTION
27
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS
(BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A
TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES
AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE
MAINTAINED.
FIRE BLOCKS.
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING
FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY
ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR
OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE-
FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE
BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS.
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES.
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS
SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER
AREAS.
ATTICS.
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM
WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE
WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION.
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL
PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES
CONSTRUCTED AS REQUIRED FOR THE PARTITIONS.
FIRE-BLOCKING & DRAFT-STOP NOTE
INSULATION SCHEDULE:
EXTERIOR WALL:
2 x 4 CONST. = R-13 MIN.
2 x 6 CONST. OR LARGER =R-19
RAISED FLOOR:R-30 MIN.
ROOF:R-30
(REF. T-24 REPORT FOR MORE INFORMATION)
NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME
NEW WALL - 2 x 6 STUDS @ 16" O.C. U.N.O.
NEW WALL - 2 x 4 STUDS @ 16" O.C. U.N.O.
WALL W/. STONE VENEER - 2x STUDS @ 16" O.C. U.N.O.
CONCRETE RETAINING WALL - REF. STRUCTURAL
SEPARATION LEGEND
EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1
1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1
1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1
INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT.
B
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'
THIRD FLOOR PLT.
27.58'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
ROOF PLATE
35.67'
ROOF PLATE
35.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
VIEW DECK
29.36'11"ROOF PLT. DECK
28.45'
2
A-5.0
3
A-5.0
5' - 11"4
A-5.0
1
A-5.0
16 15
14
3
25 24 22
13 12
21
29
6
DEN
J.J. BATH
MECH.
CABANA
CABANA
BATH #4SERVINGVIEW DECK
MASTER SUITE
HERS W.I.C.
2-CAR GARAGEPANTRYKITCHENDININGGREAT ROOM
MASTER
BALCONY
P.L.P.L.ABV. F.F.42" MIN.7 :1 2 7:12
1
ABV. F.F.42" MIN.2
3
3
3
4 5 6 5 6 7
8 9
5 10 6
9
11
12 13
145
15 15
49' - 3"1' - 1"9' - 1 3/8"11"6' - 3 5/8"10' - 4"10' - 0 3/8"6' - 3 5/8"29' - 0"24' - 0"9' - 3"1' - 1"8' - 3"1' - 1"7' - 0"10' - 4"9' - 4"FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'
THIRD FLOOR PLT.
27.58'THIRD FLOOR PLT.
27.58'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
ROOF PLATE
35.67'
ROOF PLATE
35.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
VIEW DECK
29.36'
ROOF PLT. DECK
28.45'
2
A-5.0
3
A-5.0
4
A-5.0
1
A-5.0
4 5
18 2
3
13
25 26
31
22 2125
15
6
34
20
MASTER
BALCONY W.I.C.STAIRS ELEV.LAUNDRY BALCONY #3
ELEV.STAIRSMECH.
KITCHEN ELEV. 2-CAR GARAGE
3 :1 2
3:12
7:12
ABV. F.F.42" MIN.8 9
4
16
17
7 :1 2
37
15
P.L.P.L.ABV. F.F.42" MIN.29' - 0"24' - 0"9' - 3"1' - 1"8' - 3"1' - 1"7' - 0"10' - 4"9' - 4"9' - 3"1' - 1"9' - 1 3/8"11"6' - 3 5/8"10' - 4"10' - 0 3/8"FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR PLATE (TYP.)
18.25'
SECOND FLOOR T.O.S. (TYP.)
19.33'
SECOND FLOOR T.O.S. (TYP.)
19.33'
THIRD FLOOR PLT.
27.58'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
ROOF PLATE
35.67'
ROOF PLATE
35.67'
THIRD FLR. T.O.S. (TYP.)
28.67'
VIEW DECK
29.36'ROOF PLT. DECK
28.45'
2
A-5.0
3
A-5.0
4
A-5.0
1
A-5.0
159 8 26 25
31
17
1013
4
9 2
20
5 4
1 8
BEDROOM #3
ROOF DECK
CATWALK
VIEW DECK
MASTER SUITE
HISW.I.C.
GREAT ROOMDININGKITCHEN2-CAR GARAGE
37
7 :1 2
3 :1 2 3:12
7:12
18
16
18
19 ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.145
6
20
1
P.L.P.L.7' - 0"1' - 1"8' - 3"1' - 1"9' - 3"9' - 4"10' - 4"29' - 0"24' - 0"3:12
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.A-5.1
2/05/2018
127-2018BUILDING SECTIONSBAKSHI RESIDENCE
BAKSHI RESIDENCEBOB BAKSHI127 JADE AVE. NEWPORTBEACH, CA 92662CDP
127 JADE AVE, NEWPORT BEACH, CA 92662KEYNOTE LEGEND
1 EXTERIOR GUARDRAIL - MIN. 42" HIGH - 4" MAX. SPHERE OPENING
2 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT
3 FIREPLACE - PREFABRICATED, GAS ONLY, 'DAVINCI' CUSTOM FIREPLACE (ANSI Z21.50B), FULL BAY
CONFIGURATIONS [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OTHER COMPONENTS
SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MFG'R. INSTALLATION
INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX.
FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
4 UPPER CABINET - BUILT-IN, FINISH AS SEL.
5 COUNTERTOP - AS SELECTED
6 BASE CABINET - BUILT-IN, FINISH AS SEL.
7 PROVIDE POWER FOR BUILT-IN APPLIANCE/EQUIPMENT
8 REFRIGERATOR - VERIFY APPLIANCE W/. OWNER
9 DOUBLE OVEN - AS SELECTED
10 DISHWASHER - AS SELECTED
11 SHELF AND POLE - BUILT IN, FINISH AS SEL.
12 BATHTUB - AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
13 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO.
14 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)
15 WATER HEATER - TANK-LESS (ON DEMAND-DIRECT VENT) WALL-MOUNT +44" MIN., 'NORITZ' OR EQUIV. - VERIFY
SIZE REQ'D. W/. MFGR. INSTALL PER MFGR. SPEC.
16 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS
17 BOARD & BATTEN WOOD SIDING - REF. MAT. SCHED. A/A-4.0
18 INTERIOR STAIR MOUNTED RAILING - 34"-38" ABV. NOSING, REF. DTLS. 2, 8/AD-1
19 FURNISHINGS - AS SELECTED
20 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN
1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
NO. REVISION DATE
1/4" = 1'-0"1 LONGITUDINAL SECTION
1/4" = 1'-0"2 LONGITUDINAL SECTION
1/4" = 1'-0"3 LONGITUDINAL SECTION
28