HomeMy WebLinkAbout07_Sloan Residence Coastal Development Permit _PA2018-149
CITY OF NEWPORT BEACH
ZONING ADMINISTRATOR STAFF REPORT
December 13, 2018
Agenda Item No. 7
SUBJECT: Sloan Residence (PA2018-149)
Coastal Development Permit No. CD2018-065
SITE LOCATION: 1134 East Balboa Blvd.
APPLICANT: Brandon Architects, Inc.
OWNER: Stephan and Vanessa Sloan
PLANNER: Chelsea Crager, Associate Planner
949-644-3227, ccrager@newportbeachca.gov
LAND USE AND ZONING
General Plan: RS-D (Single-Unit Residential Detached)
Zoning District : R-1 (Single-Unit Residential)
Coastal Land Use Category: RSD-B (Single-Unit Residential Detached – (6.0-9.9
DU/AC))
Coastal Zoning District: R-1 (Single-Unit Residential)
PROJECT SUMMARY
The applicant requests a coastal development permit (CDP) for the demolition of an existing
single family dwelling and the construction of a new, three-story, 2,797-square-foot single-
family dwelling and 520-square-foot two-car garage. The proposed development includes
landscape, hardscape, accessory structures, and subsurface drainage facilities all within the
confines of private property. The site is protected by an existing bulkhead that is not
proposed to be modified as a part of this permit. Work includes maintenance and repair of
an existing cantilevered deck. The design complies with all applicable development
standards and no deviations are requested.
RECOMMENDATION
1) Conduct a public hearing;
2) Find this project exempt from the California Environmental Quality Act (CEQA)
pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small
Structures), because it has no potential to have a significant effect on the environment;
and
3) Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development
Permit No. CD2018-065 (Attachment No. ZA 1).
1
Sloan Residence (PA2018-149)
Zoning Administrator, December 13, 2018
Page 2
DISCUSSION
Land Use and Development Standards
The project is located in the R-1 Zoning District, which allows a maximum of one
residential dwelling unit on a single legal lot, and is consistent with the City’s Coastal
Land Use Plan, General Plan, and Zoning Code. A CDP is required and the property
is not eligible for a Waiver for De Minimis Development because the property is
located in the Appeal Area.
The property consists of one legal lot containing an existing single-family residence.
The neighborhood is predominantly developed with two- and three-story, single-
family and two-family residences. The design, bulk, and scale of the proposed
development is consistent with the anticipated neighborhood pattern of
development.
The proposed single-family residence and accessory structures conform to all
applicable development standards, including floor area limit, setbacks, height, and
off-street parking as evidenced by the project plans and illustrated in Table 1 below:
Table 1 – Development Standards
Development Standard Standard Proposed
Setbacks (min.)
Front (East Balboa Blvd.) 2 feet 6 inches (garage)
6 feet (main building)
2 feet 6 inches (garage)
6 feet (main building)
Front (Water side, measured
from abandoned right-of-way)
0 feet 0 feet
Sides 3 feet 3 feet
Allowable Floor Area 3,360 square feet 3,317 square feet
Allowable 3rd Floor Area 336 square feet 336 square feet
Open Space 252 square feet 253 square feet
Parking 2-car garage 2-car garage
Height 24 feet flat roof
29 feet sloped roof
24 feet flat roof
29 feet sloped roof
Hazards
The lowest finished first floor elevation of the proposed residence is 9.00 feet North
American Vertical Datum of 1988 (NAVD88), which meets the minimum required
9.00-foot (NAVD88) elevation standard.
The existing development includes a private seawall/bulkhead along the waterway.
A Bulkhead Condition Report prepared by PMA Consulting, Inc., dated June 9,
2018, concludes that the existing seawall wall is in good condition without
noticeable evidence of distress. It is not anticipated that it will need repair or
replacement in the next 75 years.
2
Sloan Residence (PA2018-149)
Zoning Administrator, December 13, 2018
Page 3
A project-specific Coastal Hazards Analysis Report was prepared by PMA
Consulting, Inc., dated June 9, 2018. The bay water elevation (currently maximum
7.20 NAVD88) may exceed the current 8.45 feet NAVD88 top of bulkhead
elevation during high tide or storm events. The proposed finished floor of the
residence is 9.00 feet NAVD88 and a six-inch waterproofing curb is proposed to
be constructed around the perimeter of the dwelling that would protect against
flooding up to an elevation of 9.50 feet NAVD88. The report concludes that
flooding, wave run up and erosion will not significantly impact this property over
the expected life of the proposed development.
Pursuant to Newport Beach Municipal Code (NBMC) Section 21.30.030(C)(3)(i)(iv),
the property owner will be required to enter into an agreement with the City waiving
any potential right to protection to address situations in the future in which the
development is threatened with damage or destruction by coastal hazards (e.g.,
waves, erosion, and sea level rise). The property owner will also be required to
acknowledge any hazards present at the site and unconditionally waive any claim to
damage or liability against the decision authority, consistent with NBMC Section
21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will
need to be satisfied prior to the issuance of building permits for construction.
The property is located in an area known for the potential of seismic activity and
liquefaction. All projects are required to comply with the California Building Code
(CBC) and Building Division standards and policies. Geotechnical investigations
specifically addressing liquefaction are required to be reviewed and approved prior
to the issuance of building permits. Permit issuance is also contingent on the
inclusion of design mitigation identified in the investigations. Construction plans are
reviewed for compliance with approved investigations and CBC prior to building
permit issuance.
Water Quality
Pursuant to NBMC Section 21.35.050 (Water Quality and Hydrology Plan), because
of the project site’s proximity to coastal waters, a Water Quality and Hydrology Plan
(WQHP) was prepared by Forkert Engineering & Surveying, Inc., dated June 7, 2018.
The WQHP includes a polluted runoff and hydrologic site characterization, a sizing
standard for Best Management Practices (BMPs), and use of a low-impact
development approach to retain the design storm runoff volume on site. Construction
plans will be reviewed for compliance with the approved WQHP prior to building
permit issuance.
The project design addresses water quality with a construction erosion control plan
that outlines temporary BMPs to be implemented during constru ction to minimize
erosion and sedimentation, and to minimize pollution of runoff derived by
construction chemicals and materials. No water quality impacts to coastal waters
are anticipated based upon the location and elevation of the property.
3
Sloan Residence (PA2018-149)
Zoning Administrator, December 13, 2018
Page 4
The project includes a post construction drainage system that includes drainage and
percolation features designed to retain dry weather and minor rain event run-off on-
site. Any water not retained on-site is directed to the City’s storm drain system.
Public Access
The project site is located between the nearest public road and the sea or shoreline;
however, the project will not affect the public’s ability to gain access to, use, and/or
view the coast and nearby recreational facilities. The existing residential development
neither provides nor inhibits public coastal access. Implementation Plan Section
21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the
provision of public access bear a reasonable relationship between the requirement
and the project’s impact and be proportional to the impact. In this case, the project
replaces an existing single-family residence with a new single-family residence in an
R-1 zoning district. Therefore, the project does not involve a change in land use,
density or intensity that will result in increased demand on public access and
recreation opportunities. Furthermore, the project is designed and sited so as not to
block or impede existing public access opportunities.
The residential lot does not currently provide nor does it inhibit public coastal access.
The proposed scope of work involves the removal and replacement of an existing
single-family residence with a new single family residence. Development will occur
within the confines of private property, and existing coastal access conditions will not
be affected. Coastal access is currently provided and will continue to be provided by
street ends throughout the Balboa Peninsula with access to the beach and water,
including the D Street end adjacent to the property.
The project site is not located adjacent to a coastal view road, public viewpoint,
public park or beach, or public accessway, as identified in the Coastal Land Use
Plan. Furthermore, an investigation of the project site and surrounding area did not
identify any other public view opportunities. The project site may be located within
the viewshed of distant public viewing areas. However, the project will replace an
existing single-family home with a new single family residence that complies with
all applicable Local Coastal Program (LCP) development standards and maintains
a building envelope consistent with the existing and anticipated neighborhood
pattern of development. The cantilevered deck will be repaired and a guardrail
added without significant change. Therefore, the project does not have the
potential to degrade the visual quality of the Coastal Zone or result in significant
adverse impacts to public views.
ENVIRONMENTAL REVIEW
This project is exempt from the California Environmental Quality Act (CEQA) pursuant to
Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of
4
Sloan Residence (PA2018-149)
Zoning Administrator, December 13, 2018
Page 5
the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has
no potential to have a significant effect on the environment.
Class 3 exempts the construction and location of limited numbers of new, small facilities
or structures including a single family residence in a residential zone. The proposed
project consists of the demolition of an existing single-family residence, and the
construction of a new three-story, 2,797-square-foot, single-family residence and
attached 520-square-foot, two-car garage in the R-1 Zoning District.
PUBLIC NOTICE
Notice of this public hearing was published in the Daily Pilot, mailed to all owners and
residential occupants of property within 300 feet of the boundaries of the site (excluding
intervening rights-of-way and waterways), including the applicant, and posted on the
subject property at least 10 days before the scheduled hearing, consistent with the
provisions of the NBMC. Additionally, the item appeared on the agenda for this meeting,
which was posted at City Hall and on the City website.
APPEAL PERIOD:
This action shall become final and effective 14 days following the date the Resolution is
adopted unless within such time an appeal or call for review is filed with the Community
Development Director in accordance with the provisions of Title 21 (Local Coastal
Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City
may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the
City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through
13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal,
contact the Planning Division at 949-644-3200.
Prepared by:
GBR/cc
Attachments: ZA 1 Draft Resolution
ZA 2 Vicinity Map
ZA 3 Project Plans
5
Attachment No. ZA 1
Draft Resolution
6
RESOLUTION NO. ZA2018-###
A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE
CITY OF NEWPORT BEACH APPROVING COASTAL
DEVELOPMENT PERMIT NO. CD2018-065 TO DEMOLISH AN
EXISTING SINGLE-FAMILY RESIDENCE AND CONSTRUCT A
NEW THREE-STORY, SINGLE-FAMILY RESIDENCE AND
ATTACHED TWO-CAR GARAGE AT 1134 EAST BALBOA
BOULEVARD (PA2018-149)
THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS
FOLLOWS:
SECTION 1. STATEMENT OF FACTS.
1. An application was filed by Brandon Architects, Inc. (“Applicant”), on behalf of Stephan and
Vanessa Sloan (“Owner”), with respect to property located at 1134 East Balboa Boulevard,
requesting approval of a coastal development permit.
2. The property is legally described as Lot 18 of the East Side Balboa Tract of Newport
Beach.
3. The applicant proposed the demolition of a single-family dwelling and the construction
of a new, three-story, 2,797-square-foot single-family residence including an attached
520-square-foot two-car garage. The proposed development includes landscape,
hardscape, accessory structures, and subsurface drainage facilities all within th e
confines of private property. The site is protected by an existing bulkhead that is not
proposed to be modified as a part of this permit. Work includes maintenance and repair of
an existing cantilevered deck. The design complies with all applicable development
standards and no deviations are requested.
4. The subject property is designated RS-D (Single-Unit Residential Detached) by the
General Plan Land Use Element and is located within the R-1 (Single-Unit Residential)
Zoning District.
5. The subject property is located within the coastal zone. The Coastal Land Use Plan
category is RSD-B (Single-Unit Residential - 6.0 - 9.9 DU/AC) and the property is located
within the R-1 (Single-Unit Residential) Coastal Zone District.
6. A public hearing was held on December 13, 2018, in the Corona del Mar Conference
Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place
and purpose of the hearing was given in accordance with the Newport Beach Municipal
Code. Evidence, both written and oral, was presented to and considered by the Zoning
Administrator at this hearing.
SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION.
7
Zoning Administrator Resolution No. ZA2018-###
Page 2 of 9
1. This project is categorically exempt pursuant to Title 14 of the California Code of
Regulations Section 15303, Article 19 of Chapter 3, Guidelines for Implementation of the
California Environmental Quality Act (CEQA) under Class 3 (New Construction or
Conversion of Small Structures), because it has no potential to have a significant effect on
the environment.
2. Class 3 exempts the construction and location of limited numbers of new, small facilities
or structures including one single-family residence in a residential zone. The proposed
project consists of the demolition of an existing single-family residence and construction
of a new three-story, 2,797-square-foot, single-family residence and attached 520-
square-foot, two-car garage in the R-1 Zoning District.
SECTION 3. REQUIRED FINDINGS.
In accordance with Section 21.52.015 (Coastal Development Permits, Findings and Decision)
of the Newport Beach Municipal Code (NBMC), the following findings and facts in support of
such findings are set forth:
Finding:
A. Conforms to all applicable sections of the certified Local Coastal Program.
Facts in Support of Finding:
1. The proposed development complies with applicable residential development standards
including, but not limited to, floor area limitation, setbacks, height, and parking.
a. The maximum floor area limitation is 3,360 square feet and the proposed gross
floor area is 3,317 square feet.
b. The proposed development will provide the minimum required setbacks, which are
six (6) feet for the main building and two (2) feet six (6) inches along the front
property line abutting East Balboa Boulevard, three (3) feet along each side
property line, and zero (0) feet along the abandoned right of way abutting the
waterway.
c. The highest guardrail is no more than 24 feet, measured from the established grade
level of 9.00 feet (NAVD 88) and the highest roof ridge is no more than 29 feet,
measured from the established grade, which complies with the maximum height
limitation.
d. The project includes enclosed garage parking for two vehicles, which complies with
the minimum two-car garage parking requirement.
2. The neighborhood is predominantly developed with two- and three-story, single-family
and two-family residences. The proposed design, bulk, and scale of the development
8
Zoning Administrator Resolution No. ZA2018-###
Page 3 of 9
will be consistent with the existing neighborhood pattern of development and expected
future development.
3. The existing development includes a private seawall/bulkhead along the waterway. A
Bulkhead Condition Report prepared by PMA Consulting, Inc., dated June 9, 2018,
concludes that the wall is in good condition. There are no repairs or alterations proposed.
It is not anticipated that the wall will need repair or replacement in the next 75 years .
4. Pursuant to NBMC Section 21.30.030(C)(3)(i)(iv), the property owner will be required to
enter into an agreement with the City waiving any potential right to protection to address
situations in the future in which the development is threatened with damage or destruction
by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also
be required to acknowledge any hazards present at the site and unconditionally waive any
claim to damage or liability against the decision authority, consistent with NBMC Section
21.30.015(D)(3)(c). Both requirements are included as conditions of approval that will need
to be satisfied prior to the issuance of building permits for construction.
5. A project-specific Coastal Hazards Analysis Report was prepared by PMA Consulting,
Inc., dated June 9, 2018. The bay water elevation (currently maximum 7.20 NAVD88)
may exceed the current 8.45 feet NAVD88 top of bulkhead elevation during high tide or
storm events. The proposed finished floor of the residence is 9.00 feet NAVD88 and a
six-inch waterproofing curb is proposed to be constructed around the perimeter of the
dwelling that would protect against flooding up to an elevation of 9.50 feet NAVD88. The
report concludes that flooding, wave run up and erosion will not significantly impact this
property over the expected life of the proposed development.
6. Pursuant to NBMC Section 21.35.050 (Water Quality and Hydrology Plan), because of the
project site’s proximity to coastal waters, a Water Quality and Hydrology Plan (WQHP) was
prepared by Forkert Engineering & Surveying, Inc., dated June 7, 2018. The WQHP
includes a polluted runoff and hydrologic site characterization, a sizing standard for Best
Management Practices (BMPs), and use of a low-impact development approach to retain
the design storm runoff volume on site. Construction plans will be reviewed for compliance
with the approved WQHP prior to building permit issuance.
7. The project design addresses water quality with a construction erosion control plan and a
post construction drainage system that includes drainage and percolation features
designed to retain dry weather and minor rain event run-off on-site. Any water not retained
on-site is directed to the City’s storm drain system.
8. The property is located in an area known for the potential of seismic activity and
liquefaction. All projects are required to comply with the California Building Code (CBC)
and Building Division standards and policies. Geotechnical investigations specifically
addressing liquefaction are required to be reviewed and approved prior to the issuance of
building permits. Permit issuance is also contingent on the inclusion of design mitigation
identified in the investigations. Construction plans are reviewed for compliance with
approved investigations and CBC prior to building permit issuance.
9
Zoning Administrator Resolution No. ZA2018-###
Page 4 of 9
9. New landscaping will be verified for compliance with NBMC Section 21.30.075. A condition
of approval is included that requires drought-tolerant, and prohibits invasive, species. Prior
to issuance of the building permits, the final landscape plans will be reviewed to verify
invasive species are not planted.
10. The property is not located near designated public viewpoints or coastal view roads and
will not negatively impact public coastal views.
Finding:
B. Conforms with the public access and public recreation policies of Chapter 3 of the
Coastal Act if the project is located between the nearest public road and the sea or
shoreline of any body of water located within the coastal zone .
Facts in Support of Finding:
1. The project site is located between the nearest public road and the sea or shoreline;
however, the project will not affect the public’s ability to gain access to, use, and/or view
the coast and nearby recreational facilities. The existing residential development neither
provides nor inhibits public coastal access. Implementation Plan Section 21.30A.040
(Determination of Public Access/Recreation Impacts) requires that the provision of public
access bear a reasonable relationship between the requirement and the project’s impact
and be proportional to the impact. In this case, the project replaces an existing single-family
residence with a new single-family residence in the R-1 zoning district. Therefore, the
project does not involve a change in land use, density or intensity that will result in
increased demand on public access and recreation opportunities. Furthermore, the project
is designed and sited so as not to block or impede existing public access opportunities.
The cantilevered deck will be repaired and maintained in place.
2. The residential lot does not currently provide nor does it inhibit public coastal access. The
proposed scope of work involves the removal and replacement of an existing single-family
residence with a new single-family residence. Development will occur within the confines
of private property, and existing coastal access conditions will not be affected. Coastal
access is currently provided and will continue to be provided by street ends throughout the
Balboa Peninsula with access to the water, including at the D Street end adjacent to the
site.
3. The project site is not located adjacent to a coastal view road, public viewpoint, public
park or beach, or public accessway, as identified in the Coastal Land Use Plan.
Furthermore, an investigation of the project site and surrounding area did not identify
any other public view opportunities. The project site may be located within the viewshed
of distant public viewing areas. However, the project will replace an existing single-family
home with a new single-family residence that complies with all applicable Local Coastal
Program (LCP) development standards and maintains a building envelope consistent
with the existing and anticipated neighborhood pattern of development. Therefore, the
10
Zoning Administrator Resolution No. ZA2018-###
Page 5 of 9
project does not have the potential to degrade the visual quality of the Coastal Zone or
result in significant adverse impacts to public views.
SECTION 4. DECISION.
NOW, THEREFORE, BE IT RESOLVED:
1. The Zoning Administrator of the City of Newport Beach hereby approves Coastal
Development Permit No. CD2018-065, subject to the conditions set forth in Exhibit “A,”
which is attached hereto and incorporated by reference.
2. This action shall become final and effective 14 days following the date this Resolution
was adopted unless within such time an appeal or call for review is filed with the
Community Development Director in accordance with the provisions of Title 21 Local
Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken
by the City may be appealed to the Coastal Commission in compliance with Section
21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations,
Sections 13111 through 13120, and Section 30603 of the Coastal Act.
PASSED, APPROVED, AND ADOPTED THIS 13TH DAY OF DECEMBER, 2018.
_____________________________________
Patrick J. Alford, Zoning Administrator
11
Zoning Administrator Resolution No. ZA2018-###
Page 6 of 9
EXHIBIT “A”
CONDITIONS OF APPROVAL
1. The development shall be in substantial conformance with the approved site plan, floor
plans and building elevations stamped and dated with the date of this approval (except as
modified by applicable conditions of approval).
2. Revisions to the approved plans may require an amendment to this Coastal
Development Permit or the processing of a new coastal development permit.
3. Coastal Development Permit No. CD2018-065 shall expire unless exercised within 24
months from the date of approval as specified in Section 21.54.060 (Time Limits and
Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise
granted
4. Prior to the issuance of a building permit, an agreement in a form approved by the City
Attorney between the property owner and the City shall be executed and recorded
waiving rights to the construction of future shoreline protection devices including the
repair and maintenance, enhancement, reinforcement, or any other activity affecting the
bulkhead, that results in any encroachment seaward of the authorized footprint of the
bulkhead or other shoreline protective device. The agreement shall be binding against
the property owners and successors and assigns.
5. Prior to the issuance of a building permit, the property owner shall submit a notarized
signed letter acknowledging all hazards present at the site, assuming the risk of injury
or damage from such hazards, unconditionally waiving any claims of damage against
the City from such hazards, and to indemnify and hold harmless City, its City Council, its
boards and commissions, officials, officers, employees, and agents from and against any
and all claims, demands, obligations, damages, actions, causes of action, suits, losses,
judgments, fines, penalties, liabilities, costs and expenses (including without limitation,
attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which
may arise from or in any manner relate (directly or indirectly) to City’s approval of
development.
6. The project is subject to all applicable City ordinances, policies, and standards, unless
specifically waived or modified by the conditions of approval.
7. The applicant shall comply with all federal, state, and local laws. Material violation of
any of those laws in connection with the use may be cause for revocation of this
coastal development permit.
8. This Coastal Development Permit may be modified or revoked b y the Zoning
Administrator if determined that the proposed uses or conditions under which it is being
operated or maintained is detrimental to the public health, welfare or materially injurious
to property or improvements in the vicinity or if the property is operated or maintained
so as to constitute a public nuisance.
12
Zoning Administrator Resolution No. ZA2018-###
Page 7 of 9
9. Best Management Practices and Good Housekeeping Practices shall be implemented
prior to and throughout the duration of construction activity as designated in the
Construction Pollution Prevention Plan.
10. Prior to issuance of the building permits, a copy of the Resolution, including conditions
of approval Exhibit “A” shall be incorporated into the Building Division and field sets of
plans.
11. Prior to issuance of building permits, the applicant shall submit to the Planning Division
an additional copy of the approved architectural plans for inclusion in the coastal
development permit file. The plans shall be identical to those approved by all City
departments for building permit issuance. The approved copy shall include architectural
sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall
accurately depict the elements approved by this coastal development permit.
12. Prior to issuance of building permits, the applicant shall submit a final construction
erosion control plan. The plan shall be subject to review and approval by the Building
Division.
13. Prior to the issuance of building permits, the applicant shall submit a final landscape and
irrigation plan. These plans shall incorporate drought tolerant plantings, non -invasive
plant species and water efficient irrigation design. The plans shall be approved by the
Planning Division.
14. All landscape materials and irrigation systems shall be maintained in accordan ce with
the approved landscape plan. All landscaped areas shall be maintained in a healthy and
growing condition and shall receive regular pruning, fertilizing, mowing, and trimming.
All landscaped areas shall be kept free of weeds and debris. All irrigati on systems shall
be kept operable, including adjustments, replacements, repairs, and cleaning as part of
regular maintenance.
15. Prior to the issuance of building permits, the applicant shall pay any unpaid
administrative costs associated with the processing of this application to the Planning
Division.
16. No demolition or construction materials, equipment debris, or waste, shall be placed or
stored in a location that would enter sensitive habitat, receiving waters, or a storm drain
or result in impacts to environmentally sensitive habitat areas, streams, wetland or their
buffers.
17. The discharge of any hazardous materials into storm sewer systems or receiving waters
shall be prohibited. Machinery and equipment shall be maintained and washed in
confined areas specifically designed to control runoff. A designated fueling and vehicle
maintenance area with appropriate berms and protection to prevent spillage shall be
provided as far away from storm drain systems or receiving waters as possible.
13
Zoning Administrator Resolution No. ZA2018-###
Page 8 of 9
18. Debris from demolition shall be removed from work areas each day and removed from
the project site within 24 hours of the completion of the project. Stockpiles and
construction materials shall be covered, enclosed on all sites, not stored in contact with
the soil, and located as far away as possible from drain inlets and any waterway.
19. Trash and debris shall be disposed in proper trash and recycling receptacles at the end
of each construction day. Solid waste, including excess concrete, shall be disposed in
adequate disposal facilities at a legal disposal site or recycled at a recycling facility.
20. Should the property be sold or otherwise come under different ownership, any future
owners or assignees shall be notified of the conditions of this approval by the current
property owner or agent.
21. The applicant is responsible for compliance with the Migratory Bird Treaty Act (MBTA). In
compliance with the MBTA, grading, brush removal, building demolition, tree trimming, and
similar construction activities shall occur between August 16 and January 31, outside of
the peak nesting period. If such activities must occur inside the peak nesting season from
February 1 to August 15, compliance with the following is required to prevent the taking of
Native Birds pursuant to MBTA:
A. The construction area shall be inspected for active nests. If birds are observed flying
from a nest or sitting on a nest, it can be assumed that the nest is active. Construction
activity within 300 feet of an active nest shall be delayed until the nest is no longer
active. Continue to observe the nest until the chicks have left the nest and activity is
no longer observed. When the nest is no longer active, construction activity can
continue in the nest area.
B. It is a violation of state and federal law to kill or harm a native bird. To ensure
compliance, consider hiring a biologist to assist with the survey for nesting birds, and
to determine when it is safe to commence construction activities. If an active nest is
found, one or two short follow-up surveys will be necessary to check on the nest and
determine when the nest is no longer active.
22. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless
City, its City Council, its boards and commissions, officials, officers, employees, and agents
from and against any and all claims, demands, obligations, damages, actions, causes of
action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including
without limitation, attorney’s fees, disbursements and court costs) of every kind and nature
whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s
approval of Sloan Residence including, but not limited to, Coastal Development Permit No.
CD2018-065 (PA2018-149). This indemnification shall include, but not be limited to,
damages awarded against the City, if any, costs of suit, attorneys' fees, and other
expenses incurred in connection with such claim, action, causes of action, suit or
proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such
proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees,
and damages, which City incurs in enforcing the indemnification provisions set forth in this
14
Zoning Administrator Resolution No. ZA2018-###
Page 9 of 9
condition. The applicant shall pay to the City upon demand any amount owed to the City
pursuant to the indemnification requirements prescribed in this condition.
15
Attachment No. ZA 2
Vicinity Map
16
VICINITY MAP
Coastal Development Permit No. CD2018-065
PA2018-149
1134 East Balboa Boulevard
Subject Property
17
Attachment No. ZA 3
Project Plans
18
Name
Elevation
A101
1
SIM
Room name
150 SF
101
1i
?
90 00' 00"
Distance
N E
1
1
A101
SIM
R @ 7 1/2"20
1i
NORTH ARROW
PROPERTY LINE TAG
SECTION INDICATOR
ROOM TAG (NAME / AREA)
CALL-OUT TAG
ELEVATION INDICATOR
KEYNOTE TAG
WINDOW TAG
DOOR TAG
WALL TAG
REVISION FLAG
STAIR TAG (NO. OF RISER & HEIGHT)
ALUMINUM
CONCRETE
EARTH
GYPSUM - PLASTER
INSULATION - RIGID
MASONRY - BRICK/STONE
MASONRY - CONCRETE BLOCK
PLYWOOD / GLU-LAM TIMBER
SAND
STEEL
WOOD
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
T-1.0
10/05/2018
1134-2018TITLE SHEETSLOAN BEACH
SLOAN BEACHSLOAN RESIDENCE1134 EAST BALBOA BLVD.NEWPORT BEACH, CA92661CDP
1134 EAST BALBOA BLVD.NEWPORT BEACH, CA 92661CAITLIN SMITH
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
T-1.0
10/05/2018
1134-2018TITLE SHEETSLOAN BEACH
SLOAN BEACHSLOAN RESIDENCE1134 EAST BALBOA BLVD.NEWPORT BEACH, CA92661CDP
1134 EAST BALBOA BLVD.NEWPORT BEACH, CA 92661CAITLIN SMITH
REF. 8/T-1.0FLOOR AREA
HEIGHT
NBMC (NEWPORT BEACH MUNICIPAL CODE)
CALIFORNIA CODES: 2016 CBC, 2016 CFC, 2016 CEC,
2016 CPC, AND 2016 CMC, 2016 CAL GREEN
R-3 / U
1-HR.
CODES:
OCCUPANCY CLASSIFICATION
OCCUPANCY SEPARATIONS (GARAGE)
OCCUPANT LOAD
TYPE OF CONSTRUCTION
OWNER: ARCHITECT:
N/AALLOWABLE BLDG. AREA
(PER CBC TBL. 503)
FLOOR & FLOOR-CEILINGS N/A
BRANDON ARCHITECTS, INC.
151 KALMUS DR. STE. G-1
COSTA MESA, CA 92626
P: 714.754.4040
WWW.BRANDONARCHITECTS.COM
STRUCTURAL ENGINEER:CIVIL ENGINEER:
GENERAL CONTRACTOR:LANDSCAPE DESIGNER:
SURVEYOR:SOILS ENGINEER:SITE
1 UNIT
V-B - SPRK'R.
3 STORY
THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA ON E. BALBOA BLVD. THE LOT IS
APPOXIMATLY 29.99' WIDE BY 171.15' DEEP, IT IS ZONED R-1 AND IS APPX. 5,270 S.F. THE PROPERTY
INCLUDES A 2 STORY SINGLE FAMILY RESIDENCE TO BE DEMOLISHED. CLIENT PROPOSES TO BUILD A NEW
3 STORY SINGLE FAMILY RESIDENCES OF APPX. 3,100 S.F. INCLUDING AN ATTACHED 2-CAR GARAGE OF
APPX. 480 S.F. TO BE WOOD FRAMED WITH A SLAB FOUNDATION. THE PROJECT WILL BE CONTEMPORARAY
WITH SOME TRIDITIONAL ACCENTS. THE HOME WILL INCLUDED BUT NOT LIMITED TO THE FOLLOWING:
AMPLED INDOOR/OUTDOOR LIVING SPACES, PARKING WILL BE PROVIDED IN THE FORM OF A 2-CAR
GARAGE. THE EXTERIOR MATERIALS WILL BE OF A RICH QUALITY AND HIGH DURABILITY; CONSISTING
PRIMARILY OF HORIZONTAL WOOD SIDING, VERTICAL WOOD SIDING, AND THE USE OF SOME METAL STONE.
THE HOME WILL HAVE (3) BEDROOM, (3) FULL BATH, (1) HALF BATH AND A BONUS ROOM
FIRE SPRINKLER: NFPA 13D YES
DEFERRED SUBMITTALS
8PROJECT STATISTICS 5 3 1
249
10
AGENCIES & PUBLIC SERVICES
VICINITY MAP/ PROJECT DESCRIPTION
MATERIAL LEGEND
ANNOTATION LEGEND CODE REVIEW SHEET LISTSITE INFORMATION11
7
6SPECIAL INSPECTIONS
PROJECT DIRECTORYPROJECT DIRECTORY
PROJECT DESCRIPTION:
SLOAN BEACH
BRANDON ARCHITECTS, INC.STEPHEN & VANESSA SLOAN
1134 EAST BALBOA BLVD.
NEWPORT BEACH, CA 92661
MATT MENLOVE
UNITED CUSTOM HOMES
10725 ELLIS AVENUE
FOUNTAIN VALLEY, CA 92708
P: 949.945.0905
LIC: 949005
TBD
BUILDING AREA SCHEDULE
Name AREA COMMENTS
FIRST FLOOR 1148 SF
SECOND FLOOR 1311 SF
THIRD FLOOR 336 SF
2794 SF
GARAGE 520 SF
520 SF
GRAND TOTAL 3314 SF
OUTDOOR AREA SCHEDULE
NAME AREA COMMENTS
ENTRY 28 SF OPEN AREA
PORCH 253 SF OPEN AREA
VIEW DECK 522 SF
DECK 314 SF
GRAND TOTAL 1117 SF
APEX LAND SURVEYING, INC.
PAUL CRAFT, LIC. NO. 8516
HUNTINGTON BEACH, CA 92646
P: 714.488.5006
F: 714.333.4440
TBD
ROB MCCARTHY CONSULTING, INC.
23 CORPORATE PLAZA, SUITE 150
NEWPORT BEACH, CA 92660
P: 949.629.2539
REPORT NO. 20180502-1
TBD
SHEET #DRAWING TITLE
T-1.0 TITLE SHEET
T-1.1 GENERAL ARCHITECTURAL NOTES
T-1.2 SUPPLEMENTAL NOTES & DOCUMENTS
SUR TOPOGRAPHIC SURVEY
A-0.0 ARCHITECTURAL SITE PLAN
G-02 PRECISE GRADING PLAN
G-03 EROSION CONTROL PLAN
A-1.0 3-DIMENSIONAL VIEWS
A-2.0 FLOOR PLANS
A-3.0 ROOF PLAN
A-4.0 EXTERIOR ELEVATIONS & MATERIAL SCHEDULE
A-4.1 EXTERIOR ELEVATIONS
A-5.0 BUILDING SECTIONS
S1 FOUNDATION PLAN
AP-1 BUILDING AREA PLANS
INTERIOR DESIGNER:
JESSICA MENLOVE
801.641.2537
DIG ALERT: 1.800.227.2600
SOUTHERN CALIFORNIA EDISON: 1.714.895.0246
SOUTHERN CALIFORNIA GAS: 1.800.427.2000
CITY WATER & SEWER: 1.949.644.3011
PACIFIC BELL TELEPHONE: 1.800.750.2355
CITY OF NEWPORT BEACH
PUBLIC WORKS DEPT.: 1.949.644.3311
CITY OF NEWPORT BEACH PLANNING DEPT.:
GENERAL INFOMATION: 1.949.644.3200
ZONING INFORMATION:1.949.644.3204
CITY OF NEWPORT BEACH BUILDING DEPT.:
GENERAL:1.949.644.3275
PERMITS:1.949.644.3288
INSPECTIONS:1.949.644.3255
NEWPORT BEACH FIRE DEPARTMENT:1.949.644.3106
ORANGE COUNTY HEALTH SERVICES:1.714.834.3882
NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR
ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL TO LOCAL AGENCY
FOR REVIEW.
C.N.B. NOTE:CHRISTOPHER BRANDON, PRINCIPAL ARCHITECT IS THE DESIGN
PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE FOR
REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS,
INCLUDING PHASED AND DEFERRED SUBMITTAL ITEMS, FOR COMPATIBILITY WITH
THE DESIGN OF THE BUILDING. (NBMC 15.02.010)
1.LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR
CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4 FT. HIGH FROM THE
BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPERATE
SUBMITTAL (FOR H.O.A. PURPOSES).
2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING
STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS.
3. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275.
SOUND LEVEL NOT TO EXCEED 50dBA (55dBA WITH TIMER, 65dBA WITH TIMER AND
NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT
PROPERTY PATIO OR OPENING.
4. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR
SHORING AND UNDERPINNING. CONTRACTOR TO PROVIDE A COPY OF OSHA
PERMIT.
5. FIRE SPRINKLERS REQUIRED, CONSTRACTOR TO SUBMIT FIRE SPRINKLER
DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO SUBMITTING TO CITY. OBTAIN
FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
6. GLASS GUARD/HANDRAILS
1. REF. STRUCT. SHTS. FOR SPECIAL INSPECTION BY ENGINEER OF RECORD
2. HERS VERIFICATION REQUIRED, REF. T-24 ENERGY CALCULATIONS
LEGAL DESCRIPTION:
LOT INFORMATION:
ZONED: R-1
SITE AREA:5,270 S.F. BUILDABLE AREA: 1,680 S.F.
TOTAL ALLOWABLE AREA: 2 x 1,680 S.F. = 3,360 S.F.
REQ'D. OPEN VOLUME = 1,680X .15 = 252
MAX. THIRD FLR. ALLOWABLE = 1,680 X .2 = 336
OPEN VOLUME PROVIDED = 230 SF
EXISTING BUILDING INFORMATION:
EXISTING SINGLE FAMILY W/ GARAGE TO BE DEMOLISHED
EXISTING S.F. = 2,315 S.F. (782 S.F.) GARAGE (3 BEDS. TTL.)
ZONING INFORMATION:
FRONT SETBACK: 2.5 FT. TO GARAGE
6 FT.TO BUILDING
REAR SETBACK: 0 FT.
LEFT SETBACK: 3 FT.
RIGHT SETBACK: 3 FT.
BUILDABLE AREA: 1,619 S.F.
APN: 048-151-57
LOT 18, BLOCK 17, CITY OF NEWPORT BEACH, COUNTY
OF ORANGE, STATE OF CALIFORNIA
M.M. 107/1-7
1134 EAST BALBOA BLVD., NEWPORT BEACH, CA, 92661
NO. REVISION DATENO. REVISION DATE
LANDSCAPE AREA SCHEDULE
NAME AREA COMMENTS
L1 128 SF
L2 31 SF
GRAND TOTAL 159 SF
TITLE 24 CONSULTANT:
TBD
TOAL ENGINEERING, INC.
139 AVENIDA NAVARRO
SAN CLEMENTE, CA 92672
P.949.492.8586
PLAMEN PETROV
PMA CONSULTING, INC.
28161 CASITAS CT.,
LAGUNA NIGUEL, CA 92677
P:714.717.7542
19
PARCEL 1E BALBOA BLVD
D STREET℄℄BALBOA TRACTM.M. 6/15BLOCK KLOT 17PARCEL 3PARCEL 2LOT 18BALBOA TRACTM.M. 4/20BLOCK 17LOT 17LOT 1876.00'N26°42'52"E 168.08'70.00'6.00'30.00'62.08'N26°42'52"E 171.15'6.00'76.00'70.00'30.00'65.15'N63°17'08"W 29.99'
N69°07'43"W
3
0
.
1
5
'BASIS OF BEARINGS BENCHMARK INFORMATIONBENCHMARK NO: NB1-4-71DESCRIBED BY OCS 2002 - FOUND 3 3\4" OCS ALUMINUM BENCHMARK DISKSTAMPED "NB1-4-71", SET IN THE TOP OF A 4 IN. BY 4 IN. CONCRETE POST.MONUMENT IS LOCATED IN THE SOUTHEAST CORNER OF THE INTERSECTIONOF F STREET AND BALBOA BOULEVARD, 81 FT. SOUTHEASTERLY OFTHE CENTERLINE OF F STREET AND 27.3 FT. NORTHEASTERLY OF THECENTERLINE OF BALBOA BOULEVARD. MONUMENT IS SET LEVEL WITH THESIDEWALK.ELEVATION: 7.828 FEET (NAVD88), YEAR LEVELED 2015VICINITY MAPGRAPHIC SCALELEGAL DESCRIPTIONREAL PROPERTY IN THE CITY OF NEWPORT BEACH, COUNTY OFORANGE, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS:PARCEL 1:LOTS 18 IN BLOCK 17 OF THE EAST SIDE ADDITION TO THE BALBOATRACT, IN THE CITY OF NEWPORT BEACH, COUNTY OF ORANGE, STATEOF CALIFORNIA, AS SHOWN ON A MAP RECORDED IN BOOK 4, PAGE 20OF MISCELLANEOUS MAPS, IN THE OFFICE OF THE COUNTY RECORDEROF SAID COUNTY, TOGETHER WITH A STRIP OF LAND 6.00 FEET INWIDTH ADJOINING SAID LOT ON THE SOUTHEAST AS VACATED ANDABANDONED BY RESOLUTION NO. 5037 OF THE CITY COUNCIL OF THECITY OF NEWPORT BEACH, AND QUITCLAIMED TO THE ADJOININGOWNER BY DEED RECORDED JULY 16, 1959 IN BOOK 4801, PAGE 586,OFFICIAL RECORDS OF SAID COUNTY.PARCEL 2:LOT 18 IN BLOCK K OF BAY FRONT SECTION OF THE BALBOA TRACT, ASSHOWN ON A MAP THEREOF RECORDED IN BOOK 4801, PAGE 586, OFOFFICIAL RECORDS OF SAID COUNTY.PARCEL 3:THAT PORTION OF BAY AVENUE, 30.00 FEET IN WIDTH, AS SHOWN ONSAID MAP OF THE EAST SIDE ADDITION TO THE BALBOA TRACT, LYINGBETWEEN PARCELS 1 AND 2 ABOVE DESCRIBED, VACATED BYRESOLUTION NO. 4687 OF THE CITY COUNCIL OF THE CITY OFNEWPORT BEACH, A CERTIFIED COPY OF WHICH WAS RECORDEDSEPTEMBER 3, 1957, IN BOOK 4025, PAGE 185, OF OFFICIAL RECORDSOF SAID COUNTY.ASSESSOR'S PARCEL NUMBER: 048-151-57PAUL D. CRAFT, P.L.S. 8516 DATENOTE: SECTION 8770.6 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODESTATES THAT THE USE OF THE WORD CERTIFY OR CERTIFICATION BY ALICENSED LAND SURVEYOR IN THE PRACTICE OF LAND SURVEYING OR THEPREPARATION OF MAPS, PLATS, REPORTS, DESCRIPTIONS OR OTHER SURVEYINGDOCUMENTS ONLY CONSTITUTES AN EXPRESSION OF PROFESSIONAL OPINIONREGARDING THOSE FACTS OR FINDINGS WHICH ARE THE SUBJECT OF THECERTIFICATION AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE,EITHER EXPRESSED OR IMPLIED.LICENSE RENEWAL DATE 12/31/18STATEOFCALI
FORN
IA
P AUL
DOMINICKCRAFTExp. 12/31/18No. 8516P ROFES
S
I
ONALLANDSURVEYORTITLE REPORT/EASEMENT NOTES1134 E BALBOA BLVDNEWPORT BEACH, CA 92661(APN: 048-151-57)NO TITLE REPORT PROVIDED.CONCRETE SURFACE1 1TOPOGRAPHIC MAP
1134 E BALBOA BLVD.
NEWPORT BEACH, CA 92661
APN: 048-151-57 LEGENDEXISTING ELEVATION( )ACASPHALT PAVEMENTTEMPORARY BENCHMARKTBMWATER VALVEWVBLOCK WALLLCCENTERLINEGM GAS METERFSFLFINISHED SURFACEFLOWLINESET ON A WATER METER (WM)HUNTINGTON BEACH, CALIFORNIA 92646
PHONE:(714)488-5006 FAX:(714)333-4440
APEXLSINC@GMAIL.COM ELEVATION = 7.83 FEETSURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTYCORNERS OR OFFSETS BEFORE STARTING GRADING.PLEASE CALL PAUL CRAFT @ 714-488-5006 TO SCHEDULE.SURVEYOR'S NOTESFFFINISH FLOORNG NATURAL GROUNDTOP OF CURBTCSEARCHED, FOUND NOTHING; SETNOTHINGTHE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF EAST BALBOABOULEVARD, BEING N63°17'08"W, PER RECORD OF SURVEY NO. 2011-1163, R.S.B.260/30.EPEDGE OF PAVEMENTELPELECTRICAL PANELEGEDGE OF GUTTERSTORM DRAIN MANHOLESDMHWATER METERWMWOOD SURFACEBRICK SURFACEFHFIRE HYDRANTSEWER CLEAN OUTSCOTOP OF BULKHEADTBTOP OF DECKTDTOP OF STEPTSTOP OF WALLTWWATER07/26/201820
UP
REFREF6'PARCEL 1
LOT 18
LOT 17
℄76.00'
N26°42'52"E 168.08'
70.00'6.00'
6.00'
N26°42'52"E 171.15'
76.00'
70.00'30.00'N63°17'08"W 29.99'(7.81)
EG
(7.81)
EG
(7.82)
EG
(7.81)
EG
(8.04)TC
(7.56)FL
(7.85)TC
(7.69)FL
(7.59)
(8.02)
TC
(29.52)
ROOF
(8.69)
FF
(7.63)
FL
(8.28)FS
(7.80)
TC
(8.32)
FFG
(8.58)TB
(6.17)NG
(8.11)
DOCK
(8.16)DOCK
(4.62)NG
(7.65)
FL
(8.10)FS (7.80)FS
(37.02)
CHIMNEY TOP
(8.96)
TD
(4.41)
NG
(8.11)
TD
(4.50)
NG
(8.58)
TD
(10.02)
TW
(10.09)TW
(9.09)TD
(8.76)TD
(8.32)FS
(8.74)FS(8.70)FS(8.75)
FF
(8.55)
FS (8.10)FS
(8.12)
FS
(8.15)
FS
(8.16)NG(8.30)FS (8.14)NG(8.29)FS(8.21)FS(8.16)
FS
(7.97)
FS
(8.17)
FS
(8.12)
FS
(8.55)
TS
(8.21)TD
(8.09)FS
(8.56)TD
(8.56)FS
(8.20)FSRIDGE
(8.02)TD
(4.81)NG(7.83)WV(7.83)WM(7.76)
WV
(8.07)FS
(8.54)
TS
(8.07)FS
(8.61)FS
(8.24)FS
30.00'
EXISTING
BUILDING
EXISTING
BUILDING
DRIVEWAYFH
SCO
PLANTER
PLANTER
SCO
PROPERTY
LINE
RES. 4687 O.R. 4025/185
PROPERTY LINE6' TALL WALL
6.5' TALL WALL
BALBOA BLVD. VACATED AND
RESERVING UTILITY EASEMENT
PER 4780/77 O.R.
UP
A-4.01
A-4.0
A-4.1
A-4.1
2
1
2
3
A-5.0
3
A-5.0
2-CAR GARAGE
STAIRS
PWDR.
ELEV.
FOYER
KITCHEN
DINING
GREAT ROOM
9.00' T.O.S.
9.00' T.O.S.S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
2' - 6"
NEW 3-STORY RESIDENCE
LOT 18
BLOCK 17
M.M. 004_20
EXISTING BUILDING - NOT A PART
N26° 45'52"E 168.08'F.O.F.2' - 7 1/4"F.O.F.2' - 10 3/8"N26° 45'52"E 171.15'N63° 17'08"W 29.99'D STREETE BALBOA BLVDCENTERLINE OF STREET TO P.L.15' - 0"CENTERLINE OF STREET TO P.L.
14' - 0"
DOCK
(UNDER SEPARATE PERMIT)
NEWPORT BAY
STEP REF.
CIVIL DWGS.
PLANTER
SIDEWALK
1
A-5.0
1
A-5.0
1
A-5.2
1
A-5.2
1
A-5.1
1
A-5.1
4
A-5.1
4
A-5.1
VACATED BAY AVENUE
CLR.
22' - 0"CLR.21' - 5 1/2"2
A-5.0
2
A-5.0
UP
C.C.SIDEWALK1
2 3
4
5
5
6
7
8
99
9
10105' - 1 1/8"9' - 10 7/8"14' - 0"
11
12
F.O.F.4' - 1 1/8"4' - 3 1/8"F.O.F.3' - 0"3' - 0 1/2"F.O.F.7' - 11 1/2"8' - 0"F.O.F.3' - 0 1/2"3' - 1"F.O.F.3' - 3"3' - 3 1/2"F.O.F.3' - 0"3' - 2"F.O.F.2' - 0 1/8"2' - 2 1/8"10.02' (E.) TW
8.10' (E.) FS
8.32' (E.) FS 8.32' (E.) FS
8.11' (E.) TD
14.00' (E.) TW13
PLANTER
14
15
16
TRASH
DECKSLOP PER CIVIL
CLR.4' - 10 3/4"CLR.
4' - 4 3/4"F.O.F.3' - 1 1/2"17
18
19
NOTE: MINIMUM 6" RAISED CURB AROUND
BLDG. FOOTPRINT (9.5' TC) TO BE
WATERPROOFED AS A PREVENTATIVE
MEASURE FOR WATER INFILTRATION. REF.
TO COASTAL HAZARDOUS ANALYSIS AND
SHEET S-1.CLR.3' - 0"ENCHR.6" MAX.ENCHR.6" MAX.20
21
21
8.88'14.10' (N.) TF
CLR.
3' - 0"
22
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L L
3
A-5.1
3
A-5.1
F.Y.S.B. TO BLDG.
6' - 0"
30' - 0"
2323
23
23
ENCROACHMENT PERMIT
AGREEMENT IS REQ'D. FOR
ANY WORK PROPOSED IN
THE PUBLIC R.O.W. ALL NON-
STANDARD IMPROVEMENTS
SHALL COMPLY WITH CITY
COUNCIL POLICY L-6 AND L-
18
ENCROACHMENT PERMIT
AGREEMENT IS REQ'D. FOR
ANY WORK PROPOSED IN
THE PUBLIC R.O.W. ALL NON-
STANDARD IMPROVEMENTS
SHALL COMPLY WITH CITY
COUNCIL POLICY L-6 AND L-
18
24
24
24 24
13
11.61' T.O.R.
11.10' T.W.11.10' T.W.
25 25
(E.) 8.55 F.S.(E.) 8.70 F.S.
(E.) 8.11 T.D.
(E.) 8.11 T.D.
26
27 27
2828
28
28 28 28
29
29
EASEMENT
30' - 0"
29
30
31 32
33
33
34FAU
35
36
NOTE: PROVIDED MIN.
5/8" TYP. X GYPSUM
BOARD ON ALL WALLS
6
AD-1
6
AD-1
8
AD-1
7
AD-1
2
A-5.2
2
A-5.2
73' - 6"2' - 6"
NOTE: F.Y.S.B.
EXCEPTION TO GARAGE
2'-6" SETBACK
FRONT YARD SETBACK
EXCLUDING GRAGE
3' - 0"
L
L
L
L
L
L
L
L
L
L
L
L S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"9
10
10
F.O.F.3' - 1 1/2"3' - 2"11.61' T.O.R.
11.61' T.O.R.
PT. 1
8.24 FS
PT. 2
8.74 FS
PT. 3
8.70 FSPT. 4
8.30 FS
LAVANDULA SPP. LAVENDER (LOW WATER USE)
PLANT LEGEND
L
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-0.0
10/05/2018
1134-2018ARCHITECTURAL SITE PLANSLOAN BEACH
SLOAN BEACHSLOAN RESIDENCE1134 EAST BALBOA BLVD.NEWPORT BEACH, CA92661CDP
1134 EAST BALBOA BLVD.NEWPORT BEACH, CA 92661CAITLIN SMITH
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-0.0
10/05/2018
1134-2018ARCHITECTURAL SITE PLANSLOAN BEACH
SLOAN BEACHSLOAN RESIDENCE1134 EAST BALBOA BLVD.NEWPORT BEACH, CA92661CDP
1134 EAST BALBOA BLVD.NEWPORT BEACH, CA 92661CAITLIN SMITH
KEYNOTE LEGEND
1 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS
2 FIREPLACE - PREFABRICATED, GAS ONLY - MASON-LITE FIREPLACE, MODEL 'BURNTECH GBVS49' ICC# ESR-2401
[DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AN
INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL
BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/. THE
CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
3 EXTERIOR COMBUSTION AIR DUCTS SHALL BE LISTED COMPONENTS OF THE FIREPLACE, AND INSTALLED
ACCORDING TO THE F.P. MFGR'S. INSTR'S. (CRC R1005)
4 (E.) WATER METER LOCATION (REF. SURVEY & CIVIL DWGS.)
5 (E.) WATER VALVE (REF. SURVEY & CIVIL DWGS.)
6 (E.) FIRE HYDRANT - PROTECT IN PLACE
7 (E.) GAS METER(S) - REF. CIVIL DWGS.
8 (E.) STORM DRAIN MANHOLE
9 CURB
10 GUTTER
11 FIRE PIT LOC'N., PROVIDE GAS AS NEEDED
12 RESIDENTIAL ELEVATOR - 'GARAVENTA LIFT, UPGRADE DOOR PACKAGE STYLE 5,' SHAFT SIZE = 62" X 63 1/2"
CLEAR, SLAB DEPRESSION REQ'D PER MFGR. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE &
INSTALLATION
13 (E.) SITE WALL TO REMAIN AS-IS- PROTECT IN PLACE
14 TILE/STONE PAVERS ON CONCRETE SETTING BED OVER 'WESTCOAT ALX' W.P. MEMBRANE CLASS 'A'
ASSEMBLY (ESR-2201) REF. DTL. 10/AD-1
15 (E.) CONCRETE SLAB ON GRADE - REF. STRUCT. & CIVIL DWGS.
16 FURNISHINGS - AS SELECTED
17 STRUCTURAL STEEL COLUMN, SIZE PER STRUCT., VERIFY ALL DIMS W/. ARCH PRIOR TO STEEL FABRICATION
18 PROPERTY LINE FENCE (NEW) O. 6" CURB FOUNDATION, WOOD TO MATCH - (MAX. 6' ABV. N.G.)
19 (E.) DRIVEWAY APPROACH & CURB CUT, REPAIR AS NEEDED. STANDARD CONC. PER CNB STANDARDS.
20 (E.) SEWER C.O. LOCATION (REF. SURVEY & CIVIL DWGS.)
21 (E.) BULK HEAD - PROTECT IN PLACE
22 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) -
VERIFY LOC'N. W/. SO. CA. EDISON
23 CENTERLINE OF STREET
24 (E.) SIDEWALK - NOT A PART
25 (N.) PROPERTY LINE WALL (5' - 6" MAX. ABV. N.G.) - STUCCO FINISH TO MATCH
26 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1
27 EXISTING STRUCTURE - NOT A PART
28 SIDE YARD SETBACK
29 REAR YARD SETBACK
30 STEPPING STONE (AS SELECTED) PER. LAND. ARCH. - REF. LANDSCAPE DWGS.
31 DRAIN LINE - IN WALL/FROM ABV., TO BE METAL VERIFY W/. G.C. (REF. CIVIL DWGS. & DTLS.)
32 OVERFLOW DRAIN LINE - IN WALL/ FROM ABV., TO BE METAL VERIFY W/. G.C. (REF. CIVIL DWGS. & DTLS.)
33 WATER HEATER - TANK-LESS (ON DEMAND) WALL-MOUNT +44" MIN., 'TAKAGI' OR EQUIV. - VERIFY SIZE REQ'D. W/.
MFGR. (PROVIDE ADEQUATE N.G. CONN.) VENT THROUGH ROOF
34 FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFGR. (CMC 904.1)
35 (N.) GATE - PER LANDSCAPE DESIGNER (MAX. 5' - 6" HT. ABOVE NATURAL GRADE)
36 TRASH LOCATION - SCREEN FROM STREET AS NEEDED
TRUE NORTH
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.)
TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" - CONTACT ARCHITECT IN WRITING FOR ANY
CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
1/4" = 1'-0"1 ARCHITECTURAL SITE PLAN
PROJECT NORTH
LANDSCAPE NOTES:
1. ENCOARCHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANSCAPE PLAN, FOR ALL HARDSCAPE & PLANTING
AREAS WITH REPECTIVE HEIGHTS AND MATERIALS.
GENERAL NOTE:
SEE SHEET A-3.0 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING
EAVE DETAILS AND PROJECTION DISTANCES).
C.N.B. NOTES:
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE
APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND
RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS YOU
SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY
CONSTRUCTION AUTHORIZED BY THIS PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT
MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT.
3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING
AND UNDERPINNING.
NO. REVISION DATENO. REVISION DATE
3/16" = 1'-0"2 GRADE PLANE EXHIBIT
PT. 1 8.24
PT. 2 8.74
PT. 3 8.70
PT. 4 8.30
33.98/4 = 8.50
GRADEPLANE = 8.50'
NOTES:
1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, TRANSPORTATION, MATERIALS,
AND SERVICES NECESSARY TO FURNISH AND INSTALL ALL CONSTRUCTION
ELEMENTS AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN.
2. ALL WORK SHALL BE PERFORMED BY A CALIFORNIA LICENSED CONTRACTOR.
3. CONSTRUCTION AND INSTALLATION OF ALL LANDSCAPE ITEMS SHALL BE
ACCORDING TO STATE, COUNTY AND LOCAL CODES, ORDINANCES AND UP TO CAL-
OSHA SAFETY ORDERS REGARDING PERFORMANCE OF WORK.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING HIMSELF FAMILIAR WITH
THE NATURE AND LOCATION OF ALL UNDERGROUND UTILITIES, PIPES AND
STRUCTURES. THE CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR ALL
COSTS INCURRED DUE TO DAMAGE AND/OR REPLACEMENT OF SAID UTILITIES,
INCLUDING DELAYS.
5. ANY DISCREPANCIES BETWEEN THE FIELD CONDITIONS AND THE CONTRACT
DOCUMENTS AND/OR THE DESIGN INTENT AFFECTING THE SUCCESSFUL
COMPLETION AND COST OF THE PROJECT SHALL BE REPORTED TO THE OWNER
(JOB SUPERINTENDENT) AND LANDSCAPE ARCHITECT IMMEDIATELY. ALL WORK
RELATED TO THE PROBLEM ARE SHALL CEASE UNITIL THE DISCREPANCIES HAVE
BEEN RESOLVED BY THE OWNER (JOB SUPERINTENDENT) OR LANDSCAPE
ARCHITECT IN WRITING. ANY CONTINUATION OF WORK PRIOR TO THE RESOLUTION
OF DISCREPANCIES IS AT THE CONTRACTOR'S RISK AND EXPENSE.
6. NO WORK SHALL BE PERFORMED WITHIN THE PUBLIC RIGHT-OF-WAY BY THE
APPLICANT/OWNER, OR HIS OR HER AGENTS UNTIL A PUBLIC PROPERTY
ENCROACHMENT PERMIT IS ISSUED BY THE CITY ENGINEER.
7. CONTRACTOR SHALL INSTALL THIS PROJECT IN ACCORDANCE TO ALL CITY
CODES AND REQUIREMENTS. CONTRACTOR SHALL BRING TO THE ATTENTION OF
THE OWNER AND THE LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION ANY
KNOWN DISCREPANCY BETWEEN THAT WHICH IS SPECIFIED ON THESE PLANS AND
THAT WHICH IS PERMITTED BY GOVERNING CODES AND THE HOME OWNERS'
ASSOCIATION.
8. WITH THE ACCEPTANCE TO CONSTRUCT THIS PROJECT, CONTRACTOR AND
OWNER AGREE TO HOLD LANDSCAPE ARCHITECT HARMLESS OF ANY UNFORESEEN
CONSTRUCTION COSTS DUE TO ELEMENTS NOT SPECIFIED ON THESE PLANS.
9. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL SITE
CONDITIONS PRIOR TO COMPLETING BIDS. CONTRACTOR SHALL INCLUDE IN THEIR
BID THE COST OF ALL DEMOLITION AND ANY SOIL IMPORT AND OR EXPORT NEEDED
TO COMPLETE THIS PROJECT.
10. CONTRACTOR SHALL INSTALL THIS PROJECT UTILIZING THE LANDSCAPE
INDUSTRIES'S B.M.P. BEST MANAGEMENT PRACTICES.
GENERAL MATERIAL SPECIFICATION:
1. GROUT CELLS WITH REINFORCED CEMENT PER ASTM C150. 1
PART PORTLAND CEMENT, 2 TO 3 PARTS LOOSE SAND, 2 PARTS
COARSE AGGREGATE.
2. REINFORCING: FS = 20,000 PSI ASTM A615 GRADE 40.
3. MASONRY: FC = 1,500 PSI GRADE 'A' PER ASTM C150.
4. CONCRETE: FC = 3,500 PSI AT 28 DAYS CEMENT PER ASTM C150.
5. POUR ALL WALL FOOTINGS AGAINST NATURAL UNDISTURBED
EARTH.
6. TELEPHONE LANDSCAPE ARCHITECT IF SITE CONDITIONS ARE
NOT AS SHOWN.
PROJECT HARDSCAPE MATERIALS:
STONE SHOULD MATCH THE STONE USED ON THE HOUSE.
PAVING STONE SHALL BE SHADOW GRAY
SANDSTONE/QUARTZITE.
ALL GROUT JOINTS SHALL BE PIGMENTED PER ARCH./G.C.
APPROVAL.
ALL HARDSCAPE MATERIAL SHALL RECEIVE 6 MIL. VISQUEEN ON
UNDER SIDE FOR WATERPROOF PROTECTION.
TOTAL LANDSCAPING AREA: 143 SQFT
**ALL PLANTS TO BE DROUGHT-TOLERANT NON-INVASISE PLANT SPECIES
NOTE: GRADE PLANE IS BELOW 9.0 BFE, HEIGHT WILL BE MEASURE FRON 9.0 BFE
A
21
22
23
TDWREFREFUPW/D.UPNEW WALL - 2 x 6 STUDS @ 16" O.C.NEW WALL - 2 x 4 STUDS @ 16" O.C.WALL W/. STONE VENEER - 2 x 6 STUDS @ 16" O.C.CONCRETE RETAINING WALL - REF. STRUCTURALCONCRETE MASONRY WALL - 6" CMU U.N.O.DOUBLE WALL CONSTRUCTION - 2 x 4 MIN. STAGGERED STUD @ 16" O.C.WINDOW - REFERENCE SCHEDULEDOOR - REFERENCE SCHEDULECABINET - BUILT IN CASEWORKCOLUMN -REF. STRUCTURAL DWGS.FURNITURE - FOR PRESENTATION PURPOSES ONLYFIREPLACE - PREFAB GAS-ONLY APPLIANCEPLUMBING FIXTURE - SINK (AS SELECTED)PLUMBING FIXTURE - TOILET (AS SELECTED)PLAN LEGENDLIGHTING FIXTURE - REFERENCE ELECTRICAL PLANSFIRE RATED CEILING ASS'Y. REF. DTL. 7/AD-1INT. FIRE RATED PARTITION REF. DTL. 7/AD-1EXT. FIRE RATED PARTITION REF. DTL. 5/AD-11011i?KEYNOTE TAG - REFERENCE KEYNOTE LEGEND THIS SHT.WINDOW TAG - REFERENCE SHEET A-7.0DOOR TAG - REFERENCE SHEET A-7.01.PROVIDE WHOLE BUILDING MECHANICAL VENTILATION PER ASHRAE STANDARD 62.2-2016 SECTION 4, WITH EXCEPTION THAT NATURAL VENTILATION THROUGH DOORS AND WINDOWS IS NOT AN ACCEPTABLE ALTERNATIVE TO WHOLE-BUILDING VENTILATION (BEES 152(a), EXCEPTION 5 TO SECTION 152(a)). FOR CONTINUOUS WHOLE-BUILDING VENTILATION, MIN. REQUIRED RATE OF VENTILATION IS 1 CFM FOR EACH 100 S.F. OF CONDITIONED FLOOR AREA PLUS 7.5 CFM FOR EACH OCCUPANT (ONE OCCUPANT PER BEDROOM +1). VENTILATION TO BE PROVIDED BY EXHAUST AIR, SUPPLY AIR OR COMBINED EXHAUST AND SUPPLY AIR.2.PROVIDE IN KITCHEN LOCAL EXHAUST SYSTEM VENTED TO OUTDOORS WITH RATE = 100 CFM (PART OF WHOLE-BUILDING VENTILATION REQUIREMENT).MECHANICAL VENTILATION NOTE:CALCULATIONS:SINGLE FAMILY RESIDENCE: 3,314 S.F.(0.01)3,314 S.F.+ [7.5 CFM x OCC. (BED. +1)] =33.14 CFM + (7.5 x 4) = 63.14 CFM REQ'D.A-4.01A-4.0A-4.1A-4.1212CLR.21' - 5 1/2"CLR.4' - 6"CLR.5' - 0"3A-5.03A-5.02-CAR GARAGEPWDR.ELEV.STAIRSKITCHENDININGFOYERENTRY1A-5.01A-5.01A-5.21A-5.21A-5.11A-5.1GREAT ROOM4A-5.14A-5.12A-5.02A-5.0C.C.10101112133321122556CLR.22' - 0"4419' - 9 7/8"2' - 9 3/8"7' - 6 3/4"21' - 10 5/8"8"1/2"5' - 7 1/2"2"6' - 9"2"5' - 7 1/2"8 3/8"2' - 8"71' - 9 1/2"52' - 8 5/8"5' - 10"6' - 9"6' - 5 7/8"22' - 11 7/8"11' - 0 5/8"5' - 3 7/8"13' - 4 1/4"19' - 0 7/8"2' - 8"71' - 9 1/2"5' - 7 5/8"8' - 7"8' - 4 5/8"4 5/8"4' - 1 1/2"1' - 9 5/8"4' - 2"11 1/2"1 1/2"5' - 0 7/8"1 1/2"11 1/2"11 3/8"10' - 6"11 7/8"5' - 7 1/2"7' - 1"6' - 3 7/8"23' - 6 3/8"3' - 2"23' - 6 3/8"3' - 3 1/2"2' - 2 1/8"11 7/8"1' - 2 3/4"14' - 3 1/8"22' - 6 3/4"3' - 2"2' - 3 3/8"18' - 0"2' - 3 3/8"555559.00' T.O.S.9.00' T.O.S.68STEP UPPER CIVILMECH.3A-5.13A-5.15 3/8"21' - 1 3/8"2' - 2 1/8"3' - 2"2' - 7 7/8"2' - 7 7/8"3' - 5 1/2"1' - 7 1/2"3' - 0 1/2"2' - 3"1' - 2 1/2"1' - 7 1/2"1' - 2 5/8"6' - 9 3/8"2' - 0 1/2"2' - 4 1/8"11' - 4 3/4"4' - 6 1/8"1' - 9 5/8"2' - 6 1/2"2' - 3"2' - 1"1' - 7"3' - 10 3/4"10 1/2"3' - 0 1/8"810113' - 1 1/4"121314151617181916' - 4 3/4"5' - 0"1120202122237AD-18AD-18AD-1242572626262626272727287A-7.06AD-1NOTE: PROVIDED MIN. 5/8" TYP. X GYPSUM BOARD ON ALL WALLSSLOPE PER CIVILFAU(BELOW)CHASESTORAGE/MECH.(BELOW)27CLR.3' - 6"COUNTER SIZE11' - 0"5' - 0"2A-5.22A-5.2CLR.2' - 9"CHASE35R.Y.S.B.2' - 6"BLD. R.Y.S.B.6' - 0"536S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"EASEMENT30' - 0"VACATED BAY AVENUE3' - 3 1/2"A-4.01A-4.0A-4.1A-4.12123A-5.03A-5.0S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"1A-5.01A-5.01A-5.21A-5.21A-5.11A-5.16' - 11"4A-5.14A-5.11' - 6 1/2"2' - 2 7/8"2A-5.02A-5.0CLR.4' - 6"756891011121011121671814151617181920212223789417DN.UPMASTER SUITEMASTER BATHW/C.MASTER W.I.C.LAUNDRYELEV.BATH #2BEDROOM #2BATH #3STAIRSCLR.5' - 0"MASTERBALCONY6' - 0 1/2"68' - 5"13' - 7 1/4"6' - 0 1/8"10' - 8 5/8"6' - 7 3/8"12' - 2 7/8"19' - 2 3/4"2' - 4 5/8"8' - 10"2' - 4 5/8"1' - 10"4' - 2 1/8"4' - 1 1/2"1' - 7 5/8"4' - 11 1/2"2' - 6"4' - 1 3/8"6' - 2 3/8"6' - 0 1/2"5' - 9 7/8"2"6' - 9"2"6' - 3 7/8"3' - 2"17' - 8 1/4"9' - 1 5/8"17' - 8 1/4"6' - 0 1/2"68' - 5"2' - 4 5/8"8' - 10"1' - 10 5/8"2' - 2"3' - 11 1/2"4' - 0 1/8"3' - 6 5/8"7' - 8 1/4"4' - 5 1/8"1' - 2 5/8"9' - 0 1/8"3' - 0 3/4"4' - 10 1/4"3' - 0"4' - 10 1/4"3' - 6 1/8"2' - 11 1/2"6' - 4"2' - 5 3/8"2' - 9 1/8"6' - 3 1/2"2' - 11 3/4"SHOWERSHWRSHOWERTUB235555558' - 1 1/8"1' - 0 1/2"10 1/2"3' - 0 1/2"7' - 6"3' - 0 1/2"1' - 2 5/8"11 7/8"2' - 2 1/8"1' - 4 7/8"99MECH.3A-5.13A-5.11' - 3 1/8"13' - 1 1/4"2' - 1 1/8"4' - 0 3/8"2' - 4"9' - 11 1/4"2' - 8 1/2"2' - 3"1' - 10 1/8"4' - 8 5/8"10' - 1 1/4"5' - 9 3/8"4' - 8 7/8"1' - 10 5/8"2' - 2 1/8"2' - 11 1/2"4' - 8 1/4"4' - 6 1/2"1' - 7 1/2"5' - 5 1/8"3' - 2"3' - 7 1/2"4' - 2 5/8"3' - 10 3/4"2' - 2"2' - 2"1' - 7 5/8"5' - 6 7/8"CLR.3' - 6"CLR.3' - 6"TYP.11"TYP.11"CLR.30" MIN.12925241611CLR.30" MIN.11CLR.30" MIN.30251631123251832116252429333333202% MIN.2% MIN.343434CLR.30" MIN.CLR.30" MIN.FDFLOOR DRAIN292929CLR.3' - 4"47R @0' - 6 7/8"16AD-111AD-1113AD-19AD-11314151' - 5 5/8"2' - 6"10' - 2 1/2"2' - 6"1' - 6 3/4"CHASE2% MIN2% MIN2% MIN2 % M I N CLR.12' - 6"2A-5.22A-5.25' - 9 7/8"7' - 1"6' - 3 7/8"CLR.11' - 1 5/8"2' - 11 1/2"F.Y.S.B.6' - 0"F.Y.S.B.6' - 0"12' - 6"3' - 6"11' - 1 5/8"11' - 8 7/8"12' - 0 3/8"3' - 2"23' - 9 3/8"3' - 0 1/2"2' - 6"13' - 1 1/4"6' - 1 1/2"7' - 6 3/4"22' - 4 1/8"19' - 3 3/8"3' - 9 3/8"24172% MIN2% MIN29372929EASEMENT30' - 0"NOTE: BAY WINDOW SHALL BE ELEVATED A MINIMUM OF 18 INCHES ABOVE ADJACENT FINISH INTERIOR FLOOR SURFACE AT THE REQUIRED BUILDING SETBACK LINE.NOTE: BAY WINDOW SHALL BE ELEVATED A MINIMUM OF 18 INCHES ABOVE ADJACENT FINISH INTERIOR FLOOR SURFACE AT THE REQUIRED BUILDING SETBACK LINE.A-4.01A-4.0A-4.1A-4.12123A-5.03A-5.0S.Y.S.B.3' - 0"R.Y.S.B.2' - 6"S.Y.S.B.3' - 0"1A-5.01A-5.01A-5.21A-5.21A-5.11A-5.14A-5.14A-5.12A-5.02A-5.081927219232426252526DN.UP4VIEW DECKBONUS ROOMPOWDERELEV.MECHSTAIRSCLR.4' - 10 3/4"CLR.4' - 5"25' - 2 3/4"25' - 2 3/4"1' - 6 5/8"5' - 0"3' - 2"10' - 1"5' - 5 1/8"12' - 7 5/8"3' - 0"12' - 3 1/2"3' - 2"23' - 9 3/8"3' - 0 1/2"23' - 9 3/8"7' - 8 1/2"2' - 6 1/8"13' - 6 3/4"25' - 7 7/8"17' - 4"4' - 1 1/2"1' - 9 5/8"2' - 8 7/8"2' - 0 3/4"2' - 5 3/4"4' - 1 1/2"3' - 2"23' - 9 3/8"3' - 0 1/2"11' - 6 1/2"12' - 2 7/8"2' - 0 1/4"2' - 2 5/8"8' - 0"3' - 0 1/2"2' - 0 3/8"5' - 5 1/8"5:125:127:125:1255555545 1/8"71MECH.3A-5.13A-5.14' - 8 5/8"1' - 11 1/8"2' - 3"2' - 6 3/4"6' - 3 3/4"CLR.3' - 6"CLR.3' - 6"TYP.11"TYP.11"11123332020R @0' - 5 7/8"1R @0' - 6 7/8"169AD-1AD-111AD-111BUNKSFAU2% MIN2% MIN2% MIN2% MIN2 % M I N
2% MIN2% MIN2% MIN2% MIN2% MIN
2% MIN2% MIN2% MIN.2% MIN.2A-5.22A-5.2ø 2' - 6"5' - 11 1/8"4' - 9 3/4"6' - 7 1/4"16' - 0 7/8"7' - 5 1/2"ABV20225' - 5 3/4"2' - 5 7/8"18' - 10 1/8"3' - 2 1/8"11 7/8"2' - 2 1/8"5' - 4 1/8"8 3/8"3"2' - 9 1/2"5' - 4 1/8"8 3/8"3' - 6"9 1/8"8 3/8"5' - 4 1/8"8 3/8"3' - 0 1/2"1 1/2"12' - 2 3/4"23' - 0 7/8"CLR.3' - 10"CLR.7' - 0"7' - 10 3/8"3' - 0"8' - 5"3636383832.89'32.89'32.89'32.08'32.33'32.33'HT. CERT' REQ'DHT. CERT' REQ'DHT. CERT' REQ'DHT. CERT' REQ'DHT. CERT' REQ'D5:12JOB NO.DATEDOCUMENT VALID UPONORIGINAL SIGNATURESHEET NO.REVISIONSOWNER INFORMATION:PROJECT NAMESTATUSThese documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECTA-2.010/05/20181134-2018FLOOR PLANSSLOAN BEACHSLOAN BEACHSLOAN RESIDENCE1134 EAST BALBOA BLVD.NEWPORT BEACH, CA92661CDP1134 EAST BALBOA BLVD.NEWPORT BEACH, CA 92661CAITLIN SMITHSTAIRWAY NOTE:ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE PER CRC R303.7KEYNOTE LEGEND1 FURNISHINGS - AS SELECTED2 FIREPLACE - PREFABRICATED, GAS ONLY - MASON-LITE FIREPLACE, MODEL 'BURNTECH GBVS49' ICC# ESR-2401 [DTL.22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AN INSTALLED INACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BEPERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDSMANDATORY MEASURES.)3 EXTERIOR COMBUSTION AIR DUCTS SHALL BE LISTED COMPONENTS OF THE FIREPLACE, AND INSTALLED ACCORDINGTO THE F.P. MFGR'S. INSTR'S. (CRC R1005)4 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE (CBC 1205.4) REF. DTL. 3/AD-15 OUTLINE OF EXISTING BUILDING - TO BE DEMOLISHED6 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS7 INTERIOR HANDRAIL - 34" - 38" ABV. NOSING (36" TYP. U.N.O.), REF. DTLS. 4 & 9/AD-18 WATER HEATER - TANK-LESS (ON DEMAND) WALL-MOUNT +44" MIN., 'TAKAGI' OR EQUIV. - VERIFY SIZE REQ'D. W/. MFGR.(PROVIDE ADEQUATE N.G. CONN.) VENT THROUGH ROOF9 CHANNEL DRAIN - COPPER, SLOPED TO IN-WALL DRAIN INLETS, OVERFLOW TO BE PIPED SEPARATELY10 1-3/8" MIN. SOLID CORE DOOR, SELF CLOSING & SELF LATCHING (R302.5.1)11 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO.12 RANGE - VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFGR.)13 DISHWASHER - AS SELECTED14 KITCHEN SINK - AS SELECTED15 KITCHEN EXHAUST HOOD - PROVIDE MIN. RATE OF 100 CFM - INSTALL & PROVIDE POWER PER MFGR'S. INSTRS.16 COUNTERTOP - AS SELECTED17 BASE CABINET - BUILT-IN, FINISH AS SEL.18 UPPER CABINET - BUILT-IN, FINISH AS SEL.19 CUSTOM BUILT KITCHEN ISLAND PER OWNER & ARCH.20 1-1/2" MAX. STEP AT OUT SWING DOORS (R311.3.1)21 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) - VERIFYLOC'N. W/. SO. CA. EDISON22 FIREPLACE - PREFABRICATED, GAS ONLY - DA VINCI CUSTOM FIREPLACE, MODEL 'DAVINCI CUSTOM LINEAR GASFIREPLACE LEFT CORNER' [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTSSHALL BE LISTED AN INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS.GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY W/.THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)23 RESIDENTIAL ELEVATOR - 'GARAVENTA LIFT, UPGRADE DOOR PACKAGE STYLE 5,' SHAFT SIZE = 62" X 63 1/2" CLEAR,SLAB DEPRESSION REQ'D PER MFGR. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO PURCHASE & INSTALLATION24 BASE CABINET - SINK UNIT, BUILT-IN, FINISH AS SEL.25 SINK - AS SELECTED (VERIFY COUNTER OR WALL MOUNT FIXTURES W/. OWNER)26 PROPERTY LINE27 SIDE YARD SETBACK28 FRONT YARD SETBACK29 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-130 BATHTUB - AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)31 SHELF AND POLE - BUILT IN, FINISH AS SEL.32 WASHER - PROVIDE HOOK-UPS & POWER - INSTALL PAN & DRAIN UNDER WASHER (TYP.) - G.C. TO VERIFY LOC'N. & SIZE33 WINDOW TO MEET EGRESS REQ'TS. - REF. WINDOW NOTE #6 ON SCHEDULE34 SHOWER - HOT-MOP PAN, PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH; NET AREA 7.1 S.F. MIN.; 30" DIA. CIRCLEMIN., REF. DTL. 17/AD-135 APPLIANCE - AS SELECTED36 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THETERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITHTHE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC802.4.2.4)37 METAL ROOFING, (S.S. ZINC/KYNAR PAINTED ALUM. OR EQUIV.), REF. DTL. A/A-4 & MAT. SCHED. A-4 - COLOR AS SEL.,ARCH. TO APPV.38 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESSTHAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9)DIMENSION NOTE:ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS. 1/4" = 1'-0"1FIRST FLOOR PLAN 1/4" = 1'-0"2SECOND FLOOR PLAN*HERS VERIFICATION REQUIRED- REFERENCE T-24.1 AROUGH FRAMING:ALL EXTERIOR WALLS TO BE FRAMED WITH 2 X 6 STUDSSECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOODNO. REVISION DATETRUE NORTHPROJECT NORTH 1/4" = 1'-0"3THIRD FLOOR PLAN24
ROOF VENTILATION NOTES: (CRC R806)1. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE AT LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE PROVIDED W/. CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQ'TS. OF CRC R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR.2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE OR MORE OF THE FOLLOWING ARE MET; 1. IN CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. 2. AT LEAST 40% AND MORE THAN 50% OF THE REQUIRED VENTILATING ARE IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF TEH REQUIRED VANTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST OF THE SPACE SHALL BE PERMITTED.3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHT'G. AND AT THE LOCATION OF THE VENT.4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION INSTRUCTIONS. INSTALLATION OF VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R903. INSTALLATION OF VENTILATORS IN WALL SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION R703.1.5. UNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY AND THE ROOF RAFTERS) AND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES BETWEEN CEILINGS THAT ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBER/RAFTERS AND THE STRUCTURAL ROOF SHT'G. AT THE TOP OF THE ROOF FRAMING MEMBERS/RAFTERS) SHALL BE PERMITTED IF ALL OF THE FOLLOWING CONDITIONS ARE MET: 1. THE UNVENTED ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE. 2. NO INTERIOR CLASS I VAPOR RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED RAFTER ASEEMBLY. 3. WHERE WOOD SHINGLES OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES THE SHINGLES OR SHAKES AND THE ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. 4. IN CALIFORNIA CLIMATE ZONES 14 & 16, ANY AIR-IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR RETARDER, OR SHALL HAVE A CLASS III VAPOR RETARDER COATING OR COVERING IN DIRECT CONTACT W/. THE UNDERSIDE OF THE INSULATION (SEE TITLE 24, PART 6, FIG. 100.1-A) 5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO INSULATION SHALL BE REQ'D. WHEN ROOF TILES, WOOD SHINGLES OR WOOD SHAKES, OR ANY OTHER ROOFING SYSTEM USING BATTENS AND NO CONT. UNDERLAYMENT IS INSTALLED. A CONT. LAYER SHALL BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR ANY CONT. LAYER WHICH HAS A PERM RATE OF NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); 5.1. AIR-IMPERMEABLE INSULATION ONLY. INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. 5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION INSTALLED DIRECTLY BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET INSULATION W/. AN R-VALUE OR R-4 SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. 5.3. AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION. THE AIR-IMPERMEABLE INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. THE AIR-PERMEABLE INSULATION SHALL BE INSTALLED DIRECTLY UNDER THE AIR-PERMEABLE INSULATION. 5.4. WHERE PREFORMED INSULATION BOARD IS USED AS THE AIR IMPERMEABLE INSULATION LAYER, IT SHALL BE SEALED AT THE PERIMETER OF EACH INDIVIDUAL SHEET INTERIOR SURFACE TO FORM A CONT. LAYER.THERMAL BATT INSUL'N.EAVE FLASHING W/. DRIP (BY ROOFINGMFGR.) TO MATCH ROOF5x3 CONT. WOOD FASCIA STAIN & SEAL -VERIFY SIZE & FINISH W/. ARCH.ROOFING MATERIAL, REF. PLANSBASE FLASHING30# ROOF FELT MIN., TYP.'TYVEK' OR EQ. BLDG. WRAPPLYWD. SHT'G. (PER STRUCT'L.)INTERIOR FINISH, PER PLANCAULK & SEAL2x ROOF RAFTERS (REF. STRUCT'L.)PLYWD. SHT'G. PER STRUCT.SOLID 2x BLK'G.1x T&G O/. BLDG. WRAP - STAIN & SEAL, ARCH. TO APR'V.ROOF OH'G. DIM (REF. PLAN)*MAX. 24" FROM PL. W/. 1-HR. COND.*PROVIDE BLDG. WRAP O/. (1) LAYER 5/8"TYPE 'X' DRYWALL (1HR. COND. ONLY)EXTERIOR VENEER - REF. PLANS & ELEVS.2X BLK'G.FILLED REGION INDICATES ATTIC SPACE- REF. ATTIC VENTILATION CALCS. ROOF PLAN LEGEND1x T&G SOFFIT O/. TYVEK (OR EQUIV.)PAINT (ARCH. TO APPV.)INTERIOR FINISH, PER PLAN(WHERE OCCURS)'TYVEK' OR EQ. BLDG. WRAPCDX PLYWD. SHT'G. (PER STRUCT'L.)THERMAL BATT INSUL'N.CAULK & SEALROOFING MATERIAL (REF. PLANS)O/. 30# ROOF FELT & CDX PLYWD.ROOF SHT'G. (PER STRUCT'L.)CONT. BUILT-UP FASCIA & SHDW. BD. - ARCH. TO APPV. SIZE PRIOR TO CUTTING ROOF RAFTERSCAULK & SEALBASE FLASHINGEAVE FLASHING W/. DRIP (BYROOFING MFGR.) TO MATCH ROOFEXTERIOR FINISH - REF. PLANS & MAT. SCHED.CONT. 2x SOLID BLK'G. FOR 1-HR COND.1"OVERHANG PER PLANSSOLID 2X BLK'G. REQ'D. FOR EXTENDED RAKE COND. NOTE: 1-HR. CONDITION REQ'D. FOR RAKES THAT ARE WITHIN 5' - 0" OF PROPERTY LINEA-4.01A-4.0A-4.1A-4.12123A-5.03A-5.01A-5.01A-5.01A-5.21A-5.21A-5.11A-5.14A-5.14A-5.12A-5.02A-5.05:125:123:123:123:123:1237.98'37.49'VIEW DECK(BELOW)DECK(BELOW)8 5/8"F.O.F.14' - 6 5/8"8 5/8"F.O.F.2' - 5 3/8"25' - 2 3/4"3 1/2"F.O.F.2' - 9 1/2"F.O.F.24' - 11 1/4"8 5/8"F.O.F.24' - 9 1/8"5 5/8"7 1/2"F.O.F.2' - 9 1/2"F.O.F.5' - 4 1/8"8 3/8"F.O.F.4' - 2 5/8"5 3/8"6"8 5/8"5' - 9"2 3/4"6"F.O.F.2' - 8"3' - 10 1/2"F.O.F.5' - 5 3/4"3' - 7 7/8"F.O.F.3' - 0 1/2"1 1/2"3' - 2"111111R.Y.S.B.2' - 6"S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"3A-5.13A-5.12' - 4 3/8"23' - 1 1/2"4A-3.04A-3.04A-3.04A-3.04A-3.03A-3.03A-3.03A-3.03A-3.022334342A-5.22A-5.237.98'3:123:1237.47'8 3/4"32.89' T.O.F.HT. CERT' REQ'D33.01' T.O.R.HT. CERT' REQ'DREF. A-2.0REF. A-2.0HT. CERT' REQ'DHT. CERT' REQ'DHT. CERT' REQ'DHT. CERT' REQ'D35333A-3.03A-3.02x ROOF RAFTER (PER STRUCT.)INTERIOR FINISH(PER PLANS, WHERE OCCURS)AIR-PERMEABLE INSULATION(PER PLANS)MIN. 30# ROOF FELT- (2) LAYERS GAF VERSASHIELD UNDERLAYMENT15/32" CDX PLYWD. SHT'G.MIN. (REF. STRUCT)FASTENERS PER MFGR. INSTRUCTIONS12SLOPE PER PLANSTANDING SEAM METAL (ZINC OR EQUIV.) - REF. MAT. SCHED. A/A-5, CLASS 'A' ASSY.TYP.6" - 10"6" MIN.DOUBLE FOLD3/4" LOCK, ALT. METHODCLEATS @ 18" O.C. MAX. CONT. LOCK STRIP, SOLDEREDARCH. TO APPV.12"-16"1-1/2" HIGHVALLEY DETAILPRODUCT LISTING:ICC # ESR-2048, CB-150UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY. 1/4" DENSGLASS OR EQUIV.JOB NO.DATEDOCUMENT VALID UPONORIGINAL SIGNATURESHEET NO.REVISIONSOWNER INFORMATION:PROJECT NAMESTATUSThese documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECTA-3.010/05/20181134-2018ROOF PLANSLOAN BEACHSLOAN BEACHSLOAN RESIDENCE1134 EAST BALBOA BLVD.NEWPORT BEACH, CA92661CDP1134 EAST BALBOA BLVD.NEWPORT BEACH, CA 92661CAITLIN SMITHKEYNOTE LEGEND1 OUTLINE OF EXISTING BUILDING - TO BE DEMOLISHED2 METAL ROOFING, (S.S. ZINC/KYNAR PAINTED ALUM. OR EQUIV.), REF. DTL. A/A-4 & MAT. SCHED. A-4 - COLOR AS SEL.,ARCH. TO APPV.3 METAL GUTTER - KYNAR FINISH OR EQUIV., SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO FAB.4 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-15 ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS) 1 1/2" = 1'-0"3EAVE DETAIL 1 1/2" = 1'-0"4RAKE DETAIL 1/4" = 1'-0"1ROOF PLANNOTE: ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF FINISH FASCIAANO. REVISION DATE 1 1/2" = 1'-0"2METAL ROOFING DETAILTRUE NORTHPROJECT NORTH25
(6,8,9) WINDOWS & DOORS:
(2.) STUCCO VENEER: N/A
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER:ASSOCIATED BUILDING SUPPLY
ADDRESS:2915 RED HILL AVE., COSTA MESA, CA 92626
CONTACT:JOE YOUNAN
PHONE:714.545.3180
EMAIL:JYOUNAN@ABSSOCAL.COM
WEB:WWW.ASSOCIATEDBUILDINGSUPPLY.COM
STEEL SLIDING DOORS/WINDOWS
MANUFACTURER: BROMBAL
PRODUCT:THERMALLY BROEN STEEL WINDOWS
ADDRESS:690 SURF AVE., STRATFORD, CT 06615
PHONE:203.579.5136
WEB:WWW.BROMBALUSA.COM
(10.) GUTTERS:
SUPPLIER:TBD
MATERIAL: ALUMINUM- KYNAR FINISH
SHAPE: CONCEALED (VERIFY SIZE W/. ARCH.)
(7.) GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WWW.RANCHHOUSEDOORS.COM
STYLE: CONTEMPORARY/ MODERN
MATERIAL: CUSTOM BUILT, WOOD TO MATCH EXT. ELEMENTS
(4.) EXTERIOR ALUM. PANELING/FASCIA
WATERPROOF DECK MEMBRANE:
WESTCOAT
770 GATEWAY CENTER DRIVE
SAN DEIGO, CA 92102
800.250.4519
WWW.WESTCOAT.COM
CODE: ICC ESR-2201
PROVIDE MIN. 24 GUAGE COPPER (16 OZ.) SHEETING FOR ALL EXTERIOR FLASHING &
WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL
ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION.
FLASHING & WEATHERSTRIPPING:
(1.) METAL ROOFING: ( CLASS 'A' )
PRODUCT: STANDING SEAM ZINC ROOFING
MANUFACTURER:
TBD.
COLOR:NATURAL, TO BE APPROVED BY ARCH. & OWNER
NOTES:USE CONTINUOUS 16" OR 18" PANS - VERIFY W/. ARCH. SIZE & LOC'N. OF
SEAMS. (NO TRANSVERSE SEAMS) REF. DTL. 7/AD-2
WEIGHT:APPX. 2 PSF.
(5.) WOOD TRIM: N/A
(11.) WROUGHT IRON: N/A
(12.) STUCCO GARDEN WALLS: N/A
(13.) WOOD GATES:
(14.) COBBLESTONE DRIVEWAY:
SUPPLIER: TBD
STONE TYPE: TBD
COLOR: TBD - ARCH. TO APPROVE
APPLICATION: TBD
(15.) HARDSCAPE:
MANUFACTURER:TBD
STONE TYPE: 30" x 48" TILE
COLOR: NATURAL/ LIGHT BEIGE/GREY
APPLICATION: TBD
(2.a) WOOD T&G HORIZONTAL SIDING:
SPECIES: TBD
SIZE: HORIZONTAL, VARYING WIDTHS.
TREATMENT: TBD
APPLICATION: PER DETAIL 14/AD-1
CODE: N/A
SPECIES: TBD
SIZE: 1x6 HORIZONTAL T&G
TREATMENT: TBD
APPLICATION: PER DETAIL 14/AD-1 (SIM)
(3.)EXTERIOR STONE VENEER
N/A.
MANUFACTURER:
OLD COUNTRY MILLWORKS
5855 HOOPER AVE.
LOS ANGELES, CA 90001
AP: 323.234.2940
TYPE:KYNAR PAINTED ALUM./ ACM PANEL
COLORS: PEWTER
APPLICATION: TBD
PANEL REVEAL/SIZE: 48" VERTICAL
WEIGHT: LESS THAN 15 LBS./S.F.
MANUFACTURER:
ELDORADO STONE. LLC
1200 INDUSTRY STREET
EVERETT, WA. 98203
P: 425-407-0107
STONE TYPE:OYSTER-CUT COARSE STONE
COLOR: TBD
APPLICATION: DRY STACK, CONTINUOUS HORIZ. JOINTS, VARY HTS. & LENGTHS
(ARCH TO APPV. G.C. TO PROVIDE SAMPLE & MOCK-UPS)
THICKNESS: 1" -1.5" NOMINAL
WEIGHT:LESS THAN 15 LBS. / S.F.
APPROVALS: ICC ESR - 1215
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR T.O.S. (TYP.)
19.42'
SECOND FLOOR T.O.S. (TYP.)
19.42'
GRADE PLANE
9.00'GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
3
A-5.0
ROOF PLATE (TYP.)
35.92'
VIEW DECK PLATE
28.50'
VIEW DECK PLATE
28.50'
1
A-5.1
LOWER ROOF PLATE (TYP.)
35.25'
VIEW DECK T.O.S.
29.39'
VIEW DECK T.O.S.
29.39'
8
P.L.P.L.9' - 4"1' - 1"9' - 1"10 5/8"5' - 10 3/8"10' - 5"9' - 11 5/8"29' - 0"24' - 0"ABV. F.F.42" MIN.ABV. F.F.42" MIN.5' - 9"1' MAX37.98'
32.89'
HT CERT. REQ'D HT CERT. REQ'D
3 :1 2 3:12
HT CERT. REQ'D
10' - 5"9' - 11 5/8"6' - 6 3/8"9' - 0"1
5
5
3
30
8
9
2' - 0"
7
6
2
3 :1 2
2
A-5.2
37
37.98'
3:12
S.Y.S.B.
3' - 0"
S.Y.S.B.
3' - 0"
1' - 8 1/2"
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR T.O.S. (TYP.)
19.42'
SECOND FLOOR T.O.S. (TYP.)
19.42'
THIRD FLOOR PLATE (TYP.)
27.50'
THIRD FLOOR PLATE (TYP.)
27.50'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
THIRD FLOOR T.O.S. (TYP.)
28.58'
THIRD FLOOR T.O.S. (TYP.)
28.58'
VIEW DECK PLATE
28.50'
1
A-5.0
1
A-5.2
4
A-5.1
LOWER ROOF PLATE (TYP.)
35.25'
LOWER ROOF PLATE (TYP.)
35.25'
2
A-5.0
VIEW DECK T.O.S.
29.39'
21
123
3
4
56
457
78
910
11.1
7
19
21
P.L.ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.6' - 8"1' - 1"8' - 1"1' - 1"9' - 4"9' - 2"10' - 5"9' - 5"1' - 1"8' - 1"1' - 1"9' - 4"9' - 2"10' - 5"10 5/8"9' - 1"1' - 1"9' - 4"9' - 11 5/8"5 :1 2 5:12
1 :1 2
32.92'
37.98'
32.89'32.33'
HT CERT. REQ'D HT CERT. REQ'D
HT CERT. REQ'D HT CERT. REQ'D
HD. HT.8' - 8 3/8"TYP.7' - 6"HEAD HT.7' - 6"1
2
3
4
5
5SILL HT.4' - 0"HEAD HT.7' - 6"SILL HT.3' - 0"3
A-5.1
MAX.1' - 0"MIN.2' - 0"1
1
1
1
2
3
A-7.0
1
TYP.
2
A-7.0
3
A-7.0
672
A-7.0
3
A-7.0
4
2
2
10
37.98'37.98'37.49'
HT CERT. REQ'D HT CERT. REQ'D
3 :1 2
3:12
SILL. HT.4' - 6"T.O.C.9' - 4"5' - 9 3/8"ABV. F.F.1' - 11 5/8"SETBACK
F.Y.S.B.
6' - 0"
F.Y.S.B. GARAGE
2' - 6"
SETBACK
VACANT EASEMENT
30' - 0"
2' - 3 3/8"
2' - 4 1/8"
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-4.0
10/05/2018
1134-2018EXTERIOR ELEVATIONS &MATERIAL SCHEDULESLOAN BEACH
SLOAN BEACHSLOAN RESIDENCE1134 EAST BALBOA BLVD.NEWPORT BEACH, CA92661CDP
1134 EAST BALBOA BLVD.NEWPORT BEACH, CA 92661CAITLIN SMITH
KEYNOTE LEGEND
1 WOOD SIDING - REF. DTL. 5/AD-1 & MATERIAL SCHEDULE A-4
2 EXT. ADHERED STONE VENEER - REF. MATERIAL SCHEDULE SHT. A-4, DTL. 8/AD-1
3 VERTICAL WOOD SIDING, SEE MATERIAL SCHEDULE A-4.0 AND DTL 8/AD-1.
4 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1
5 STEEL CHANNEL FASCIA - ARCH. TO APPV. SIZE & COLOR
6 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL
NOT BE LESS THAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC
2113.9)
7 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE
INSTALLED AT THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE
LISTED AND LABELED FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN
ACCORDANCE W/. MFGR. INST. INSTRUCTIONS. CMC 802.4.2.4)
8 EXTERIOR GLASS GUARDRAIL - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTLS. 4 & 17/AD-1
9 EXPOSED STEEL COLUMN, SIZE PER STRUCTURAL & PAINT AS SEL. - ARCH. TO APPV.
10 EXTERIOR LIGHTING - TO BE HIGH EFFICIENCY, LOW EFFICIENCY MAY BE PROVIDED PER ELECTRICAL
NOTE #33
MATERIAL SCHEDULEA
NOTE: REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS.
NOTE: FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT
LABELS.
NO. REVISION DATE
1/4" = 1'-0"1 FRONT ELEVATION
1/4" = 1'-0"2 LEFT SIDE ELEVATION
26
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR T.O.S. (TYP.)
19.42'
SECOND FLOOR T.O.S. (TYP.)
19.42'
THIRD FLOOR PLATE (TYP.)
27.50'
THIRD FLOOR PLATE (TYP.)
27.50'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
3
A-5.0
THIRD FLOOR T.O.S. (TYP.)
28.58'
THIRD FLOOR T.O.S. (TYP.)
28.58'
ROOF PLATE (TYP.)
35.92'
1
A-5.1
LOWER ROOF PLATE (TYP.)
35.25'
4
811
9
P.L.P.L.9' - 4"1' - 1"8' - 1"1' - 1"7' - 4"10' - 5"9' - 2"9' - 4"1' - 1"8' - 1"1' - 1"6' - 8"10' - 5"9' - 2"29' - 0"24' - 0"1
2
3
7' - 9"CURTAIN WALL F.V.
6' - 4"
CURTAIN WALL F.V.
6' - 3 1/2"
4
5 CURTIAN WALL F.V.5' - 9"ABV. F.F.42" MIN.32.33'
32.92'
19.42'CURTAIN WALL F.V.5' - 9"2
A-5.2
3 :1 2 3:12 3 :1 2 3:12
18
3
SILL HT.2' - 0"37.98'
HT CERT. REQ'D
37.98'37.47'
HT CERT. REQ'DHT CERT. REQ'D
HT CERT. REQ'D
S.Y.S.B.
3' - 0"
S.Y.S.B.
3' - 0"
1' - 8 1/2"
2' - 0 1/8"
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR T.O.S. (TYP.)
19.42'
SECOND FLOOR T.O.S. (TYP.)
19.42'
THIRD FLOOR PLATE (TYP.)
27.50'THIRD FLOOR PLATE (TYP.)
27.50'
GRADE PLANE
9.00'GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
THIRD FLOOR T.O.S. (TYP.)
28.58'
THIRD FLOOR T.O.S. (TYP.)
28.58'
ROOF PLATE (TYP.)
35.92'
ROOF PLATE (TYP.)
35.92'
VIEW DECK PLATE
28.50'
1
A-5.0
1
A-5.2
4
A-5.1
2
A-5.0
VIEW DECK T.O.S.
29.39'
52
12
11
14 15
12
13
161718
27 26
24 23
25
9' - 4"1' - 1"8' - 1"1' - 1"7' - 4"10' - 5"9' - 2"9' - 1"10 5/8"9' - 11 5/8"ABV. F.F.42" MIN.ABV. F.F.42" MIN.9' - 4"1' - 1"8' - 1"1' - 1"7' - 4"10' - 5"9' - 2"29' - 0"24' - 0"P.L.
5:12
1:12
3:12
32.89'
37.98'
32.33'32.92'
HT CERT. REQ'D
HT CERT. REQ'D HT CERT. REQ'D
HT CERT. REQ'D
6
6
3
A-5.1
3
333
3
3
7
7
8
9
2
MIN.2' - 0"MAX.1' - 0"CURTAIN WALL F.V.9' - 0"CURTAIN WALL F.V.
5' - 7 1/2"
10 11
SILL HT.3' - 6"HD. HT.8' - 0"SILL HT.3' - 2"HEAD HT.6' - 8"12
13
7
8
9
14
15
6
AD-1
8
AD-1
8
AD-1
5
AD-1
5
AD-1
A-7.0
1
TYP.
16
17
17
ABV. F.F.42" MIN.3 :1 2
37.98'CURTAIN WALL F.V.9' - 0"CURTAIN WALL F.V.
5' - 7 1/2"ABV. LANDING4' - 9"ABV. LANDING3' - 6"F.Y.S.B.
6' - 0"
F.Y.S.B. GARAGE
2' - 6"
VACANT EASEMENT
30' - 0"
2' - 3 3/8"
2' - 4 1/8"
(6,8,9) WINDOWS & DOORS:
(2.) STUCCO VENEER: N/A
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER:ASSOCIATED BUILDING SUPPLY
ADDRESS:2915 RED HILL AVE., COSTA MESA, CA 92626
CONTACT:JOE YOUNAN
PHONE:714.545.3180
EMAIL:JYOUNAN@ABSSOCAL.COM
WEB:WWW.ASSOCIATEDBUILDINGSUPPLY.COM
STEEL SLIDING DOORS/WINDOWS
MANUFACTURER: BROMBAL
PRODUCT:THERMALLY BROEN STEEL WINDOWS
ADDRESS:690 SURF AVE., STRATFORD, CT 06615
PHONE:203.579.5136
WEB:WWW.BROMBALUSA.COM
(10.) GUTTERS:
SUPPLIER:TBD
MATERIAL: ALUMINUM- KYNAR FINISH
SHAPE: CONCEALED (VERIFY SIZE W/. ARCH.)
(7.) GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WWW.RANCHHOUSEDOORS.COM
STYLE: CONTEMPORARY/ MODERN
MATERIAL: CUSTOM BUILT, WOOD TO MATCH EXT. ELEMENTS
(4.) EXTERIOR ALUM. PANELING/FASCIA
WATERPROOF DECK MEMBRANE:
WESTCOAT
770 GATEWAY CENTER DRIVE
SAN DEIGO, CA 92102
800.250.4519
WWW.WESTCOAT.COM
CODE: ICC ESR-2201
PROVIDE MIN. 24 GUAGE COPPER (16 OZ.) SHEETING FOR ALL EXTERIOR FLASHING &
WEATHERSTRIPPING APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL
ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION.
FLASHING & WEATHERSTRIPPING:
(1.) METAL ROOFING: ( CLASS 'A' )
PRODUCT: STANDING SEAM ZINC ROOFING
MANUFACTURER:
TBD.
COLOR:NATURAL, TO BE APPROVED BY ARCH. & OWNER
NOTES:USE CONTINUOUS 16" OR 18" PANS - VERIFY W/. ARCH. SIZE & LOC'N. OF
SEAMS. (NO TRANSVERSE SEAMS) REF. DTL. 7/AD-2
WEIGHT:APPX. 2 PSF.
(5.) WOOD TRIM: N/A
(11.) WROUGHT IRON: N/A
(12.) STUCCO GARDEN WALLS: N/A
(13.) WOOD GATES:
(14.) COBBLESTONE DRIVEWAY:
SUPPLIER: TBD
STONE TYPE: TBD
COLOR: TBD - ARCH. TO APPROVE
APPLICATION: TBD
(15.) HARDSCAPE:
MANUFACTURER:TBD
STONE TYPE: 30" x 48" TILE
COLOR: NATURAL/ LIGHT BEIGE/GREY
APPLICATION: TBD
(2.a) WOOD T&G HORIZONTAL SIDING:
SPECIES: TBD
SIZE: HORIZONTAL, VARYING WIDTHS.
TREATMENT: TBD
APPLICATION: PER DETAIL 14/AD-1
CODE: N/A
SPECIES: TBD
SIZE: 1x6 HORIZONTAL T&G
TREATMENT: TBD
APPLICATION: PER DETAIL 14/AD-1 (SIM)
(3.)EXTERIOR STONE VENEER
N/A.
MANUFACTURER:
OLD COUNTRY MILLWORKS
5855 HOOPER AVE.
LOS ANGELES, CA 90001
AP: 323.234.2940
TYPE:KYNAR PAINTED ALUM./ ACM PANEL
COLORS: PEWTER
APPLICATION: TBD
PANEL REVEAL/SIZE: 48" VERTICAL
WEIGHT: LESS THAN 15 LBS./S.F.
MANUFACTURER:
ELDORADO STONE. LLC
1200 INDUSTRY STREET
EVERETT, WA. 98203
P: 425-407-0107
STONE TYPE:OYSTER-CUT COARSE STONE
COLOR: TBD
APPLICATION: DRY STACK, CONTINUOUS HORIZ. JOINTS, VARY HTS. & LENGTHS
(ARCH TO APPV. G.C. TO PROVIDE SAMPLE & MOCK-UPS)
THICKNESS: 1" -1.5" NOMINAL
WEIGHT:LESS THAN 15 LBS. / S.F.
APPROVALS: ICC ESR - 1215
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-4.1
10/05/2018
1134-2018EXTERIOR ELEVATIONSSLOAN BEACH
SLOAN BEACHSLOAN RESIDENCE1134 EAST BALBOA BLVD.NEWPORT BEACH, CA92661CDP
1134 EAST BALBOA BLVD.NEWPORT BEACH, CA 92661CAITLIN SMITH
NO. REVISION DATE
NOTE: REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS.
1/4" = 1'-0"1 REAR ELEVATION
1/4" = 1'-0"2 RIGHT SIDE ELEVATION
KEYNOTE LEGEND
1 VERTICAL WOOD SIDING, SEE MATERIAL SCHEDULE A-4.0 AND DTL 8/AD-1.
2 METAL ROOFING, (S.S. ZINC/KYNAR PAINTED ALUM. OR EQUIV.), REF. DTL. A/A-4 & MAT. SCHED. A-4 - COLOR AS
SEL., ARCH. TO APPV.
3 WOOD SIDING - REF. DTL. 5/AD-1 & MATERIAL SCHEDULE A-4
4 DECO. STEEL C CHANNEL BEAM, SIZE & PAINT AS SEL. - ARCH. TO APPV.
5 CUSTOM STOREFRONT GLAZING SYSTEM - TO BE FIELD VERIFIED, REF. LEFT SIDE ELEVATION SHT. A-6
6 STEEL CHANNEL FASCIA - ARCH. TO APPV. SIZE & COLOR
7 DOWNSPOUT - METAL OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
8 METAL GUTTER - KYNAR FINISH OR EQUIV., SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO FAB.
9 ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS)
10 CHIMNEY CAP/SPARK ARRESTOR - AS SELECTED (NOTE: DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT
THE TERMINATION OF FACTORY BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED
FOR USE WITH THE SPECIFIC FAC. BLT. CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE W/. MFGR.
INST. INSTRUCTIONS. CMC 802.4.2.4)
11 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT
BE LESS THAN 3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9)
12 EXT. ADHERED STONE VENEER - REF. MATERIAL SCHEDULE SHT. A-4, DTL. 8/AD-1
13 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION) -
VERIFY LOC'N. W/. SO. CA. EDISON
14 PARAPET WALL - PRECAST CONC. SILL FINISH O/. FLASHING, SLOPED TOP (2% MIN.)
15 EXTERIOR WALL MOUNTED LIGHT FIXTURE (HIGH EFFICIENCY) SIZE AS SEL., DOWNLIGHT TYP. U.N.O.
16 EXPOSED STEEL COLUMN, SIZE PER STRUCTURAL & PAINT AS SEL. - ARCH. TO APPV.
17 WINDOW TO MEET EGRESS REQ'TS. - REF. WINDOW NOTE #6 ON SCHEDULE
18 PRECAST CONC. CAP - SLOPE 2% MIN., ARCH. TO APPV.
MATERIAL SCHEDULEA
NOTE: REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS.
27
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS
(BOTH VERTICAL AND HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A
TOP STORY AND A ROOF OR ATTIC SPACE, AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES
AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE BLOCKS AND DRAFT STOPS SHALL BE
MAINTAINED.
FIRE BLOCKS.
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING
FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND
HORIZONTAL.
FIRE BLOCK CONSTRUCTION. FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY
ALSO BE OF GYPSUM BOARD, CEMENT FIBER BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR
OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. LOOSE-
FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE
BLOCKS OF BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS.
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES.
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS
SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER
AREAS.
ATTICS.
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM
WALLS AND SIMILAR CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE
WITH THE WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION.
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL
PANEL, 3/8-INCH TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES
CONSTRUCTED AS REQUIRED FOR THE PARTITIONS.
FIRE-BLOCKING & DRAFT-STOP NOTE
INSULATION SCHEDULE:
EXTERIOR WALL:
2 x 4 CONST. = R-13 MIN.
2 x 6 CONST. OR LARGER =R-19
RAISED FLOOR:R-30 MIN.
ROOF:R-30
(REF. T-24 REPORT FOR MORE INFORMATION)
NOTE: PROVIDE BID FOR INSULATION OF ENTIRE HOME
NEW WALL - 2 x 6 STUDS @ 16" O.C. U.N.O.
NEW WALL - 2 x 4 STUDS @ 16" O.C. U.N.O.
WALL W/. STONE VENEER - 2x STUDS @ 16" O.C. U.N.O.
CONCRETE RETAINING WALL - REF. STRUCTURAL
SEPARATION LEGEND
EXTERIOR FIRE RATED PARTITION REF. DTL. 5/AD-1
1 HR. FIRE RATED PARTITION REF. DTL. 7/AD-1
1 HR. FLOOR SYSTEM REF. DTL. 7/AD-1
INSULATED SYS. REF. INSULATION SCHEDULE THIS SHT.
B
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR T.O.S. (TYP.)
19.42'
SECOND FLOOR T.O.S. (TYP.)
19.42'
THIRD FLOOR PLATE (TYP.)
27.50'
THIRD FLOOR PLATE (TYP.)
27.50'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
THIRD FLOOR T.O.S. (TYP.)
28.58'
THIRD FLOOR T.O.S. (TYP.)
28.58'
VIEW DECK PLATE
28.50'
1
A-5.0
1
A-5.2
4
A-5.1
LOWER ROOF PLATE (TYP.)
35.25'
LOWER ROOF PLATE (TYP.)
35.25'
2
A-5.0
VIEW DECK T.O.S.
29.39'ABV. F.F.42" MIN.ABV. F.F.42" MIN.P.L.
2 1
1 2 3
3 13 12
18197
54
25 26
9 10
65
9ABV. F.F.42" MIN.ABV. F.F.42" MIN.9' - 4"1' - 1"8' - 1"1' - 1"6' - 8"10' - 5"9' - 2"29' - 0"24' - 0"MASTER SUITE
VIEW DECK
BONUS ROOM
BEDROOM #2
2-CAR GARAGE
FOYER
DINING
1
14 15
13
1
5:12
1:12
2% MIN.2% MIN.
2% MIN.
2% MIN.2% MIN.
3
3
3
1
1
16
12
17
SLOPE PER CIVIL9' - 0 3/4"9' - 4"8' - 1"8' - 1"3
A-5.1
7
AD-1
29
27
30
31MIN.2' - 0"MAX.1' - 0"3
3
33
3
3
16
AD-1
21
2% MIN.
32
A-7.0
7
AD-1
13
8' - 1"8' - 7 3/4"29' - 0"24' - 0"9' - 4"1' - 1"9' - 1"10 5/8"5' - 10 3/8"10' - 5"9' - 11 5/8"9' - 4"1' - 1"8' - 1"1' - 1"6' - 8"10' - 5"9' - 2"3 :1 2 3:12
2525
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR T.O.S. (TYP.)
19.42'
SECOND FLOOR T.O.S. (TYP.)
19.42'
THIRD FLOOR PLATE (TYP.)
27.50'
THIRD FLOOR PLATE (TYP.)
27.50'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
3
A-5.0
THIRD FLOOR T.O.S. (TYP.)
28.58'
THIRD FLOOR T.O.S. (TYP.)
28.58'
ROOF PLATE (TYP.)
35.92'
1
A-5.1
LOWER ROOF PLATE (TYP.)
35.25'
BONUS ROOM POWDER
LAUNDRYMASTER W.I.C.
FOYER
2023
8
9' - 4"1' - 1"8' - 1"1' - 1"7' - 4"10' - 5"9' - 2"9' - 4"1' - 1"8' - 1"1' - 1"6' - 8"10' - 5"9' - 2"P.L.P.L.
3 :1 2 3:12
0 .4 2 :1 20.4 2 :1 2
1
2
3
4
5
6
7
3
8
9 10
11 1
12
3
13
8' - 1"8' - 1"8' - 1"8' - 7 3/4"8' - 3 5/8"27
28
1225 25 T.O.C.9' - 4"2
A-5.2
3 :1 2 3:12
1
2
:
1
2
FIRST FLOOR (T.O.S.)
9.00'
FIRST FLOOR (T.O.S.)
9.00'
MAX. RIDGE HEIGHT
38.00'
MAX. RIDGE HEIGHT
38.00'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR PLATE (TYP.)
18.33'
SECOND FLOOR T.O.S. (TYP.)
19.42'
SECOND FLOOR T.O.S. (TYP.)
19.42'
THIRD FLOOR PLATE (TYP.)
27.50'
THIRD FLOOR PLATE (TYP.)
27.50'
GRADE PLANE
9.00'
GRADE PLANE
9.00'
MAX FLAT
33.00'
MAX FLAT
33.00'
3
A-5.0
THIRD FLOOR T.O.S. (TYP.)
28.58'
THIRD FLOOR T.O.S. (TYP.)
28.58'
ROOF PLATE (TYP.)
35.92'
ROOF PLATE (TYP.)
35.92'
1
A-5.1
LOWER ROOF PLATE (TYP.)
35.25'
LOWER ROOF PLATE (TYP.)
35.25'8' - 1"8' - 1"9' - 4"9' - 4"3 :1 2 3:12
MECH
STAIRS
BATH #2
PWDR.
10
1415
9
TYP6 7/8"P.L.P.L.
1819
19
27
0.42:120.42:12
20 19
21
21
TYP.
11"8' - 3 3/8"22
7
7
R @ 0' - 6 7/8"16ABV. F.F.42" MIN.23
23
3 3
29' - 0"24' - 0"9' - 4"1' - 1"8' - 1"1' - 1"7' - 4"10' - 5"9' - 2"9' - 4"1' - 1"8' - 1"1' - 1"6' - 8"10' - 5"9' - 2"2425 25
26
33
2
A-5.2
TYP.7 3/8"TYP.
11"36" TYP.34" - 38"36" TYP.34" - 38"3 :1 2 3:12
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
A-5.0
10/05/2018
1134-2018BUILDING SECTIONSSLOAN BEACH
SLOAN BEACHSLOAN RESIDENCE1134 EAST BALBOA BLVD.NEWPORT BEACH, CA92661CDP
1134 EAST BALBOA BLVD.NEWPORT BEACH, CA 92661CAITLIN SMITH
KEYNOTE LEGEND
1 FURNISHINGS - AS SELECTED
2 DECO. WD. PANELING - PAINT GRADE - COLOR AS SEL.
3 ROOF RAFTERS - REF. STRUCT.
4 SHELF AND POLE - BUILT IN, FINISH AS SEL.
5 WASHER - PROVIDE HOOK-UPS & POWER - INSTALL PAN & DRAIN UNDER WASHER (TYP.) - G.C. TO VERIFY
LOC'N. & SIZE
6 UPPER CABINET - BUILT-IN, FINISH AS SEL.
7 TOILET - MIN. 24" CLR. IN FRONT, MIN. 30" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO.
8 KITCHEN EXHAUST HOOD - PROVIDE MIN. RATE OF 100 CFM - INSTALL & PROVIDE POWER PER MFGR'S.
INSTRS.
9 RANGE - VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFGR.)
10 CUSTOM BUILT KITCHEN ISLAND PER OWNER & ARCH.
11 COUNTERTOP - AS SELECTED
12 (E.) CONCRETE SLAB ON GRADE - REF. STRUCT. & CIVIL DWGS.
13 EXT. ADHERED STONE VENEER - REF. MATERIAL SCHEDULE SHT. A-4, DTL. 8/AD-1
14 FIREPLACE - PREFABRICATED, GAS ONLY - MASON-LITE FIREPLACE, MODEL 'BURNTECH GBVS49' ICC#
ESR-2401 [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL
BE LISTED AN INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS.
GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST
COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
15 EXTERIOR COMBUSTION AIR DUCTS SHALL BE LISTED COMPONENTS OF THE FIREPLACE, AND INSTALLED
ACCORDING TO THE F.P. MFGR'S. INSTR'S. (CRC R1005)
16 DECO WOOD BEAM PAINT & SEAL AS SEL. - ARCH TO APPV.
17 VEHICLE - MINIMUM PARKING DIMENSIONS ON PLANS
18 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS
THAN 1 FOOT CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
19 INTERIOR HANDRAIL - 34" - 38" ABV. NOSING (36" TYP. U.N.O.), REF. DTLS. 4 & 9/AD-1
20 FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFGR. (CMC 904.1)
21 WALL MOUNTED LIGHT FIXTURE, SCONCE
22 BASE CABINET - SINK UNIT, BUILT-IN, FINISH AS SEL.
23 FLOOR JOISTS - REF. STRUCT.
24 (N.) CONCRETE SLAB ON GRADE - REF. STRUCT. & CIVIL DWGS.
25 CONCRETE FOOTING - REF. STRUCTURAL
26 METAL GUTTER - KYNAR FINISH OR EQUIV., SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO FAB.
27 CEILING FAN - W/. INCANDESCENT FIXTURE, AS SELECTED
28 DECORATIVE PENDANT LIGHT FIXTURE
29 LINEAR FLUORESCENT FIXTURE - CEILING MOUNT (ALT. RECESS)
30 EXTERIOR GLASS GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 13/AD-1
31 PARAPET WALL - PRECAST CONC. SILL FINISH O/. FLASHING, SLOPED TOP (2% MIN.)
32 DECO. STEEL C CHANNEL BEAM, SIZE & PAINT AS SEL. - ARCH. TO APPV.
33 PROVIDE FAN TO COMPLY W/. WHOLE HOUSE VENTILATION REQUIREMENT - SEE MECH. VENT. NOTE/E-1
(ARCH. TO APPV. LOC'N.)
NO. REVISION DATE
1/4" = 1'-0"3 LONGITUDINAL SECTION
1/4" = 1'-0"2 TRANSVERSE SECTION
1/4" = 1'-0"1 TRANSVERSE SECTION
28
TDWREFREF
W/D.UP
UP
1148 SF
FIRST FLOOR
520 SF
GARAGE
28 SF
ENTRY128 SF
L1
31 SF
L2
FLOOR PLAN
A
B
C
D
E
0' - 10 3/8" X 0' - 6 1/2" = 0.47 S.F.
18' - 5 3/8" X 5' - 2 7/8" = 96.66 S.F.
0' - 10 1/8" X 13' 5 1/2" = 11.36 SF
22' - 10 3/4" X 32' - 6 1/4"= 744.59S.F.
F
0' - 4 1/4" X 5' - 6" = 1.95 S.F.
1' - 2 1/8" X 13' - 6 3/4" = 15.96 S.F.
TOTAL: 1147.61 SF
G
H
I
22' - 10 3/4" X 22' - 8 5/8" = 520.16 S.F.
22' - 10 3/4" " X 11' - 6 3/8"= 264.02 S.F.
J
0' - 10 3/8" X 0' - 6 1/2" = 0.47 S.F.
11' - 1 1/8" X 1' - 1 1/8" = 12.13 S.F.A
B6 5/8"D
E
FG
H
IJ
TOTAL: 479.21 SF
C
22' - 8 5/8"11' - 6 3/8"5' - 2 7/8"32' - 6 1/4"10 1/8"22' - 10 3/4"22' - 10 3/4"1' - 1 1/8"11' - 1 1/8"10 3/8"10 3/8"13' - 6 3/4"5' - 6"13' - 5 1/2"1' - 2 1/8"4 1/4"18' - 5 3/8"6 1/2"1311 SF
SECOND FLOOR
253 SF
PORCH 17' - 6 5/8"21' - 1 3/8"2' - 9"16' - 3 3/8"23' - 9 7/8"13' - 8 1/4"5' - 11 1/8"10' - 9 1/4"6' - 7 1/8"12' - 4 1/4"19' - 1 7/8"1/8"
6' - 1 3/4"4' - 4 1/4"5' - 0"2' - 8 1/2"1' - 5 7/8"FLOOR PLAN
A
B
C
D
E
16' - 1 3/8" X 3' - 6 3/4" = 57.41 S.F.
2' - 11 3/8" X 0' - 6 5/8"= 1.63 S.F.
15' - 9 1/4" X 12' 4 1/4" = 194.84 SF
17' - 6 5/8" X 19' - 2"= 336.41 S.F.
F
6' - 7 1/8" X 23' - 10 3/8"= 157.38 S.F.
2' - 10 1/2" X 0' - 6 5/8" = 1.59 S.F.
TOTAL: 1310.92 SF
A
B
C
DEF
I
H
G
J
KL
G
H
I
21' - 1 3/8" X 19' - 8 3/4" = 416.57 S.F.
2' - 9" X 10' - 9 1/4"= 29.62 S.F.
J
7' - 1 1/4" X 4' - 4 1/4"= 30.93 S.F.
5' - 0" X 6' - 1 3/4" = 30.73 S.F.
K
L
M
0' - 11" X 3' - 6 5/8" = 3.26 S.F.
0' - 6 1/2" X 7' - 1 1/4"= 3.85 S.F.
N
1' - 6 3/8" X 5' - 11 1/8"= 9.08 S.F.
2' - 9" X 13' - 8 1/4"= 37.64 S.F.
FIRST FLOOR PLAN
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
GARAGE
TTL. LIVING
GRAND TOTAL
1176 SF
1,341 SF
336 SF
520 SF
2,853 SF
3,373 SF 11"4' - 4 1/4"7' - 1 1/4"
3' - 6 5/8"
2' - 11 3/8"2' - 10 1/2"6 5/8"15' - 9 1/4"19' - 2"23' - 10 3/8"16' - 1 3/8"1' - 6 3/8"7' - 1 1/4"3' - 6 3/4"6 1/2"19' - 8 3/4"
13' - 8 1/4"
M
N
2' - 9"336 SF
THIRD FLOOR
522 SF
VIEW DECK
314 SF
DECK 1' - 3 1/8"3' - 8 5/8"6' - 3 3/4"11' - 8 5/8"12' - 0 3/4"10' - 2 5/8"7' - 5"
A
B
C
D
E
FLOOR PLAN
A
B
C
D
E
0' - 6" X 0' - 8" = .33 S.F.
10' - 8" X 3' - 8 5/8"= 39.65 S.F.
12' - 0 3/4" X 10' - 2 5/8"= 123.19 S.F.
11' - 6 1/2" X 7' - 5" = 85.6 S.F.
F
6' - 7 1/4" X 11' - 8 5/8"= 77.39 S.F.
7' - 6 5/8" X 1' - 3 1/8"= 9.51 S.F.
TOTAL: 335.67 SF
F
7' - 6 5/8"
6 1/8"10' - 7 7/8"8"FIRST FLOOR PLAN
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
GARAGE
TTL. LIVING
GRAND TOTAL
1176 SF
1,341 SF
336 SF
520 SF
2,853 SF
3,373 SF 11' - 6 1/2"12' - 0 3/4"6' - 7 1/4"
6"10' - 8"8"JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT MANAGER/ARCHITECT
AP-1
10/05/2018
1134-2018BUILDING AREA PLANSSLOAN BEACH
SLOAN BEACHSLOAN RESIDENCE1134 EAST BALBOA BLVD.NEWPORT BEACH, CA92661CDP
1134 EAST BALBOA BLVD.NEWPORT BEACH, CA 92661Designer
BUILDING AREA SCHEDULE
Name AREA COMMENTS
FIRST FLOOR 1148 SF
SECOND FLOOR 1311 SF
THIRD FLOOR 336 SF
2794 SF
GARAGE 520 SF
520 SF
GRAND TOTAL 3314 SF
OUTDOOR AREA SCHEDULE
NAME AREA COMMENTS
ENTRY 28 SF OPEN AREA
PORCH 253 SF OPEN AREA
VIEW DECK 522 SF
DECK 314 SF
GRAND TOTAL 1117 SF
LOT INFORMATION:
NO. REVISION DATE
LANDSCAPE AREA SCHEDULE
NAME AREA COMMENTS
L1 128 SF
L2 31 SF
GRAND TOTAL 159 SF
1/8" = 1'-0"1 FIRST FLOOR (T.O.S.)
1/8" = 1'-0"2 SECOND FLOOR T.O.S. (TYP.)
1/8" = 1'-0"3 THIRD FLOOR T.O.S. (TYP.)
ZONED: R-1
SITE AREA:5,270 S.F. BUILDABLE AREA: 1,619 S.F.
TOTAL ALLOWABLE AREA: 2 x 1,619 S.F. = 3,070 S.F.
REQ'D. OPEN VOLUME = 1,619 X .15 = 242.85
MAX. THIRD FLR. ALLOWABLE = 1,619 X .2 = 323.8
OPEN VOLUME PROVIDED = 959 SF
29
1
Subject:FW: Written comments of ZA Item 2 (Finley Tract RP3)
Attachments:2018Dec13_ZA_Item_2_Comments_JimMosher.pdf
From: Jim Mosher [mailto:jimmosher@yahoo.com]
Sent: Thursday, December 13, 2018 1:37 PM
To: Alford, Patrick <PAlford@newportbeachca.gov>
Cc: Campbell, Jim <JCampbell@newportbeachca.gov>
Subject: Written comments of ZA Item 2 (Finley Tract RP3)
I will not be able to attend this afternoon's Zoning Administrator hearing due to its being scheduled at
the same time as the Finance Committee meeting.
Please find attached some quick comments on Item 2 (PA2017-132).
With regard to Item 7 (PA2018-149), it seems unlikely the City has jurisdiction over the cantilevered
deck mentioned in the project summary (if it is over tidal waters).
Yours sincerely,
Jim Mosher
Zoning Administrator - December 13, 2018
Item No. 7a - ADDITIONAL MATERIALS RECEIVED
Sloan Residence (PA2018-149)