HomeMy WebLinkAboutX2019-0036 - MiscCity of Newport Beach Special Inspector Manual
CITY OF NEWPORT BEACH
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DIVISION
100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658
N. v�t� n%woofs i�eechcz •n;v 1 (949) 644-3200
SPECIAL INSPECTION REPORT
40+0036
953 Newer} Cen4er Dr
RECEIVED By
COMMUNITY
DEVELOPMENT
JUN 14 2019
CITY OF
yFwPORT 5S?'
Project Address: 953 Newport Center Drive
Permit Number: X2019-0036
Inspection Type (s): Epoxy
Inspection Date (s): 5-20-19 ( ) Periodic (X) Continuous
Describe Inspection, Including Location(s):
1. Inspected embedment procedures to install ASTM A-615 qr.60 #4 rebar
dowels using Simpson SET -XP epoxy adhesive (exp. 2/11/21) at the locations
described below:
A) #4@16"o.c. at new to existing slab on grade at Storefront, per det. 12/S1.1.
B #4 @ 16" at exist. -new concrete slab (with foam infillper RFI to follow.
David K. Archuleta
List Tests Made:
Visual for size depth' cleanliness of drilled holes and epoxy t e ex iration.
Total Inspection Time Each Day:
Date:
5/20/19
Hours:
4
i
Ust All Items Requiring Correction linclude previously Listed Uncorrected Items):
RFI to follow describing retrofit attachment of new to existing concrete slab wiith
engineered foam infill.
Comments:
To the best of my knowledge, the work inspected was in accordance with the Building Division approved design drawings,
specifications and applicable workmanship provisions of the U.B.C. except as noted above.
ci ector ignature:
Date:
5-20-19
Print Full Name:
Newport Beach Reglctration No.:
David K. Archuleta
NB -0690
67
City of Newport Beach Special Inspector Manual
CITY OF NEWPORT BEACH
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DIVISION
100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658 .
wvvw newpoilbeachca.gw, 1 (949) 644-3200
SPECIAL INSPECTION REPORT
Project Address: 953 Newport Center Drive
Permit Number: X2019-0036
Inspection Type (s): Reinforced Concrete
Inspection Date (s): 5-30-19 ( ) Periodic (X) Continuous
Descrihe Inspection, Including Location(s):
1. Inspected placement of approx. 60 d3 of ASTM C-94 Concrete per Bender
Ready Mix #450038 4500 psi, 3/8" agg., 5" slum at slab on grade our -
backs at Utility Trench 2 ea. Storefront entry locations and miscellaneous
pothole repairs and at new to existing concrete slab with foam infill per S2.1
and details 13-16/S1.1 of approved Revised plan dated 5/24/19.
List Tests Made:
Slump, temperature. _
Ust All Items Requiring correction (Include Previowly Listed Uncorrected Items);
Item requiring clarification per Daily Report dated 5-20-19 is addressed by approved
Revised Plan Delta4 dated 5/24/19 a e SM.
Comments:
To the best of my knowledge, the work inspected was in accordance with the Building Division approved design drawings,
specifications an applicable workmanship provisions of the U.D.C. except as noted above.
d actor ignature:
Date:
5-30-19
Print Full Name:
Newport Beach Registration No.:
David K. Archuleta
NB -0690
.&}512015
67
City of Newport Beach Special Inspector Manual
Project Address:
Permit Number:
CITY OF NEWPORT BEACH
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DIVISION
100 Civic Center Drive I P.O_ Box 1768 1 Newport Beach, CA 92658
nro.�u n��r:nr.�nBeachr ., *'v 1 (949) 644-3200
SPECIAL INSPECTION REPORT
r Drive
',�'OEIVED BY
COMMUNCTy
DEVELOPMENT
JUN 14 2019
CITY OF
G�
IFWPORT �gP
Inspection Type (s): EPDXY
Inspection Date (s): 5-13-19 ( ) Periodic (X) continuous
Describe Inspection, Including Location(s):
1. Inspected embedment procedures to install ASTM A-615 qr.60 #5 rebar dowels
at 12" o.c. at existing to new footingper detail 13/S1.1, at Storefront using
Simpson SET -XP epoxy adhesive (exp. 10/17/20). Complete.
Print full Name:
Newport Beach Registration No.:
David K. Archuleta
List Tests Made:
Size, depth and celeanlines of drilled holespeLexp. of epoxyIty .
Total Inspection Time Each Day:
Date:
5-13-19
Hours:
4
To the best of my knowledge, the work inspected was in accordance with the Building Division approved design drawings,
specifications an tl applicable workmanship provisions of the U.B.C. except as noted above.
KCI ector Sig nature:
Date:
5-13-19
Print full Name:
Newport Beach Registration No.:
David K. Archuleta
NB -0690
67
City of Newport Beach Special Inspector Manual
0OgNUNI � Y
COMM
CITY OF NEWPORT BEACH DF"0PMENT
COMMUNITY DEVELOPMENT DEPARTMENT JUN 14 2019
BUILDING DIVISION
100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658 ca'( OF
nnv„1 (949) 644-3200 CZ,
SPECIAL INSPECTION REPORT 'VEWPotaT BSP
Project Address: 809 Newport Center Drive
Permit Number: X2019-0035
Inspection Type
Inspection Date (s): 5-14-19 ( ) Periodic (X) continuous
Describe Inspection, Including Location(s):
1. Inspected placement and mechanical consolidation of approx. 19 d3 of
ASTM C-94 concrete perBender Ready Mix#45K`1824001 4500 psl, 3/8”
agg., 5" slum at 2 ea. new to existing footings per detail 13/S1.1 and new
to existing slab on grade pourbacks iper detail 121S1.1 at Storefront.
ALPerformed water control and sam lin of concrete.
David K. Archuleta
List Tests Made:
Slump, temperature.
Total Inspection Time Each Day:
Data:
5-14-19
Hours:
4
List All Items Requiring Correction Include Previously Listed Uncorrected Items):
None
Comments:
To the best of my knowledge, the work inspected was in accordance with the Building Division approved design drawings,
specifications an U applicable workmanship provisions of the U.B.C. except as noted above,
cl ector Signature:
Date:
5-14-19
Print Full Name:
Newport Beach Registration No.:
David K. Archuleta
NB -0690
ONxslllns
67
Report of Special Inspection
Project Name & Address 809 Newport Center Drive Newport Beach, CA 92660
Permit Number X2019-0035
Inspection
Structural Steel Welding
InspectionDate(s) 05/21/19 ty periodic
Describe Inspection Made, including locations:
Observed fit up and tack welding:
- 1/4" (2-12) Fillet welds of (N) WF beam to (E) WF beam (Typ)
- 1/4" Fillet welds of 3/8" Shear PL. to (E) W6x Col. (Typ) all around
- 1/4" (2-12) Flare Beveled welds of C4x4.5 cont. C -Channel to 4" Dia.
STD pipe Col. (Typ) 2 sides.
- IX' f=illet welds of WT4x to. C4x4.5 C -Channel.
@ Gridlines: X33/Y15-Y16, Ref Det: 1/51.2, 3/S1.2, 2/51.2, 3/S1.2, 5/S1.5
All completed welds were visually acceptable per AWS D1.1.
AWS Certified Welder 1: Jose M. Sierra, #571-75-7922
Weld. Method. Used- FCAW-E71T-8, MR -232,0727 Dia.; Egwp: MillerTrailblazer.
280
Status: Work Completed.
List Tests. Made
Total Inspection Time Each Day:
List Items Requiring Correction, Include Uncorrected Items Previously Listed:
To the best of my knowledge, the work inspected was in accordance with the Building Department
approved design drawings, specifications and applicable workmanship provisions of the IBC except as
noted above. i-%
05/21/19
Print Full Name: Kimbo-Ung Registration No. NB -0722
FORM 81-R, 2014
STRUCTURAL INSPECTION CONSULTANTS
ARCHULETA INSPECTIONS
OFFICE/FAX: (626) 309-0055
CELL: (626) 235-8947 (24 HOURS)
WEBSITE: ARCHULETAINSPECTIONS.COM
REGISTERED INSPECTOR'S DAILY REPORT
Project Address
Reinforced Concrete
Permit #
Fire Proofing
Inspection
809 Newport Center Drive Newport Beach, CA 92660
Drilled -In Anchors
X2019-0035
City
— Reinforced Masonry
Project #
_
_ Other
Newport Beach
19.00926 -CA
Engineer
Weather
Brandon &Johnston
Indoor
Contractor
Temperature
KDC Construction
70 Deg.
Type of
Reinforced Concrete
X Structural Steel_
Fire Proofing
Inspection
— Pre -Stressed Concrete
Drilled -In Anchors
Epoxy
Required
— Reinforced Masonry
_
_ Shotcrete/Gunite
_
_ Other
DATE: 5/21 /19
Observed fit up and tack welding:
- 1/4" (2.12) Fillet welds of (N) WF beam to (E) WF beam (Typ)
- 1/4" Fillet welds of 3/8" Shear PL. to (E) W6x Col. (Typ) all around
- 1/4" (2-12) Flare Beveled welds of C4x4.5 cont. C -Channel to 4" Dia. STD pipe Col. (Typ) 2 sides.
- 1/4" Fillet welds of WT4x to C4x4.5 C -Channel.
Q Gridlines: X33/Y15-Y16, Ref Det: 1/S1.2, 3/S1.2, 2/S1.23 3/S1.2, 5/S1.5
All completed welds were visually acceptable per AWS D1.1.
AWS Certified Welder 1: Jose M. Sierra, #571-75-7922
Weld Method Used: FCAW-E71T-8, NR -232,072" Dia., Equip: MillerTrailblazer 280
Status: Work Completed.
CERTIFICATE OF COMPLIANCE
ALL WORK LISTED ABOVE WAS INSPECTED AS REQUIERD BY
THE APPROVE AN, SPECIFICATIONS, AND GOVERNING CODE
i$imbo Ung._
SIGNATURE OF REGISTERED INSPECTOR
ICC -8391227
NUMBER
TIME IN TIME OUT REG. HOURS O.T. HOURS SAMPLES
10:00pm. 6:00am. 8
Alt inspecdom-based'on a mimmum of4 ftomsarm over4 hours— 8hmrrsmimmunr
-if the Inspector is called-toapm}eet and no -worlds pert'orme..4
y -two hour minimum
charge will be applied..r��y
Approved by Dave Dragon /�
Pmject Superintendent
M ARCIETECT, ENGINEER, BU". GOFFICW. WHITE -OFFICE COPY CANARY -INSPECTOR'S COPY PINK-JOBCOPY FOR]Wg M-690