HomeMy WebLinkAboutS2018-0222 - MiscContinuous Inspection & Materials Testing
1115pectiO11 & 'resting,, Inc. 441 Commercial Way, La Habra, CA 90631-6168
(562)941-2990 ^ (774)526-8441
FAX (562)946-0026
FIELD DATA ON TEST SPECIMENS
--- ASTM C31, C138, C143, 0172, C173, C231, 01064 ---coq Mo,.tkbar Dr-
CONCRETE:
rCONCRETE: MORTAR: SHOTCRETE: X CORES: GUNITE:
ADDRESS: 609 MALABAR DR. NEWPORT BEACH JOB #: DATE: 03/01/2019
JOB NAME: DANA POINT TRUST PERMIT #: S2018-0222 ISSUED BY:
ARCHITECT: ENGINEER: LACHER ENGINEERING
CONTRACTOR: SWAN POOLS SUB: WEST COAST SHOTCRETE
LOCATION IN STRUCTURE: FLOOR OF THE POOL
TRACT: PHASE: LOT #:
CONCRETE SUPPLIER: GARY BALE PLANT: MIX #: 71/2 -1
TYPE OF CEMENT: V ADMIXTURE: TICKET #:286742
SLUMP: 0.00 in, WATER ADDED: 0 gal. AIR TEMP: 0 F
CONCRETE TEMP: MIXING TIME: TIME CAST: 07:45
DATE CAST: 01128/2019 RECEIVED AT LAB: 02122(2019
SPECIMENS, MADE BY: ERICLUIZ SPECIFIED PSI @ 28 Days: 4500
LAB #: 135755 CLIENT: RICHARD'LUIZ
TESTING INFORMATION:
SAMPLE IDENTIFICATION:
1802604
1802605
1802606
AGE DAYS:
28:
28
28
DATE TEST:
02/25/2019
02/25/2019
02/2512019
SIZE (in.): Height X Diameter
8.000 X 4.005
8.000 X 4.009
8:000 X 4.005
AREA (in.k):.
12:60
12.62
12.60
CRUSH LOAD (lbs.):
66560
65210
64752
COMPRESSIVE STRENGTH (psi.):
5280
5170
15140
HEIGHT -DIAMETER RATIO:
CORRECTION FACTOR:
CORRECTED STRENGTH (psi:):
BREAK TYPE:
III
IV
III
C.T.M. USED:
Forney96
Forney96
Forney96
REMARKS:
ASTM C39, C174, C192, C470, C617, C42
COMPLIES: X DOES NOT COMPLY: FOR INFORMATION:
THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC.
SAMPLES CAST BY OTHERS:
RESPECTFULLY SUBMITTED
SOUTHWEST INSPECTION AND TESTING
NOTICE:These test results are from. samples cast by inspectors
or technicians: not employed by our firm. They were
either delivered to our laboratory or picked up by our
driver. We will accept no responsibility for the inspection
made on the jobsiteby the inspector, furthermore we
ER
do not take responsibility for any informatiomon this
LAB
report other than the strength as tested and reported.
ASTM 039 BREAKS: 1=CONE - 11=CONE AND SPLIT -
111=COLUMNAR - IV=SHEAR - V --SIDE FRACTURES - VI=POINTED
City of Newport Beach Special Inspector Manual
CITY OF NEWPORT BEACH
n
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DIVISION
f �i r,tpoln>�� 100 Civic Center Drive I P.O. Boz 1768 Newport Beach, CA 92658
awJw.ne+Noorlbeachca.gov [ (949) 644-3200
Project Address.
Permit Number:
Inspection Type
Inspection Date
01 M446
?d [8'-0222
c�.
( ) Periodic (X) Continuous
Describe Inspection, Including Location(s):
Ser he- x etn}' &0 a rokimaie dh of 4560 F5kdziI
Fe -(,r 4 ke IRif 001
A +Ik ChCd K. A(f ct e...eko �e 6oyeG
6Wt eeft
Gi G�oY IN o faNS' Awr.� 4td�.
Newport Beach Registration No.:
Fri c LHix
j
..
List'rests Mader
I //
om res5(On -te sjbtlft. lei wort -66K rON+. [.te:-r-.(Oar Ot 4146 o L
Total Inspection Time Each Day:
Hours
List All items Requiring Correction(include Previously Listed Uncorrected Items):
OPIe.
To the hest of myknowledge, the work inspected was in accordance with the Building Division approved design drawings,
specifications and aoplicabie workmanship provisions of the U.B.C. except as noted above.
Special inspector signature:
Date:
fie:
A6 -[
Print Full .N
Newport Beach Registration No.:
Fri c LHix
j
N B"b7H
apeuaimspemonnepprt ae/ea)Nlb
67
OL Acoustics
F;f72-j7-1:��/, 1, /.4 i/ ,
Sgiis-W=
609 Mrafabar br
14301 Middletown Lane Westminster, CA 92683
Voice/Fax 714.373.3050 dlubman@dlacoustics.com
June 18, 2019
Homeowner
609 Malabar Dr.
Corona Del Mar, CA, 92625 Report emailed to: sgrasso@swanpools.com
ifraser@swanpools.com
Pool and or Spa Noise report for residence at 609 Malabar Dr., Corona Del Mar, CA
Dear Homeowner:
At about 11:00 a.m. Tuesday, June 18, 2019 1 measured the pool and or spa equipment noise at
your nearest neighbor's residence to test for compliance with the Newport Beach noise
regulation (10.26.025).
Newport Beach Residential Noise Standard
For Noise Zone 1 (residential) the N. B. regulation's daytime noise level standard (maximum
noise level from 10 p.m. to 7 a.m.) is 55 dBA— corrected for ambient noise. The nighttime noise
standard (max noise level from 7 a.m. to 10 p.m.) is 50 dBA. The measurement is corrected for
ambient noise and rounded to the nearest decibel as shown below.
I am pleased to report that measured pool and or spa apparatus noise meets the Newport
Beach noise standard for 24-hour use. Pertinent details of my findings are reported below.
Locations and values of daytime noise measurements
Uncorrected pool and or spa noise + ambient noise measured at property line: 50.20 dBA
Ambient noise level measured at this location: not needed
Pool and or spa equipment noise corrected for ambient noise: not applicable
Pool and or spa equipment noise rounded to the nearest decibel: 50 dBA
50 dBA (Pass for 24 hour ease)
The currently installed pool and or spa apparatus noise of 50 dBA meets the Newport Beach
noise code for both "daytime" use (7 a.m. to 10 p.m.) and "nighttime" use (10 p.m. to 7 a.m.),
since the noise corrected for ambient does not exceed 50 dBA.
If you have any questions about this report, please do not hesitate to contact me at (714) 373-
3050 or by email at dlubmanla)dlacoustics.com
Sincerely yours,
f" luiv Q/ri.
David Lubman, FASA, FINCE
Acoustical Consultant
Orange County Certification #200524
June 18, 2019
APPENDIX A:
Measurement Instrumentation
Equipment
The acoustical equipment used in the performance of this test is in accordance with
ASTM and ANSI (American National Standards Institute) requirements. Key elements
are as follows:
Critical sound measuring instruments (sound analyzer, calibrator, and microphone) are
annual calibrated by an independent NAVLAP certified laboratory. The most recent
calibration was on 08/01/18. All calibration documents are available for inspection upon
request.
Critical instruments employed were:
Bruel & Kjaer — Type 2270 Type I Precision Sound Analyzer SN # 3002720
Bruel & Kjaer - Type 4189 microphone, SN # 2850866
Bruel & Kjaer — Type 4231 Field Sound Calibrator, SN # 2588671