Loading...
HomeMy WebLinkAboutX2019-2205 - CalcsVOR 4905 308 Morning SfarZn blh2.com STRUCTURAL CALCULATIONS (SLIDER HEADER ONLY) for 308 MORNINGSTAR LN. NEWPORT BEACH, CA 92660, ccs PREPARED BY: BARRY L HUSEAL, P.E. (CA # 28761) I F I c Structural Engineering Construction Consulting Expert'feedimony 3251 Rintcrast Or. 116 Aguirre Rd, Laguna Reach, CA 92651 YFhuridc, CO 81435 949/715-3700 949/715-3800 VAX 949/233.5187 B SHEETNO.— OF CALCULATED BY DATE CHECKED BY DATE SCALE MEMBER REPORT Level, Roof., Drop Beam 4 plece(s) 13/4" x 117/8" 2.0E Mlc rollam0 LVL Overall Length: 24' N N All locations are measured from the outside face of left support (or left cantilever end).AII dimensions are horizontal. Design Results Actual Location Allowed Result WF Load: Combination (Pattern) Member Reaction (lbs) 4490 @ 23'8" 27913 (5.50") Passed (16%) -- 1.0 D + 1.0 Lr (AII Spans) Shear (I Its) 3836 @ 22'6 5/8" 19742 Passed (1945) 1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft -lbs) 21109 @ 13' 6 5/8" 44621 Passed (47%) 1.25 1.0 D + 1.0 Lr (All Spans) Idve Load per. (in) 0.424 @ 12' 4 7/8" 0.778 Passed (L/660) -- 1.0 D + 1.0 Lr (All Spans) Total Load Deg. (in) 1.066 @ 12'4 1/2" 1.167 Passed L/263 - 1.0 D + 1.0 Lr (AJ1 Spans) • DenecOon criteria: LL (1.1360) and TL (1/240). Top Edge Bracing (Lu): Top compression edge must be braced at 22' 4" o/c unless delalied otherwise. • Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 24' o/c unless delalled otherwise. • Member should be side -loaded from both sides of the member to prevent rotation. Bearing Length Lead, tosupports (ib.) Supports Total Available RequiredP1552 l�e Total Accessories f - Column - SPF 5.50' 5.50" 150" 960 2512 Blacking 1 -Column -SPF 5.50" 5.50" 1.50" 1815 4490 Blocking Blocking Panels areassumed to carryno loads applied direcUv,b,, them and the full load Is aoolled I the member heron dremn, Loads Location (side) Tributary width Dead (0.90) Roof Live (non-snovr. Lia) comments 0 -SO W,Ight(PLF) Oto 24' II/A 24.2 C i - Uniform(PLF) l8'10 24'(Fronl) IVA 243.0 185.0 Roof 2 -Tapered (PLF) 0 to 18' (front) Il/A 0.0 to 243.0 OA to 165.0 PASSED (_... System: Roof Plember Type: Drop Beam Building Use ; Reslden0a1 Building Code: IBC 2015 Design Methodology: ASD Member Pitch: 0/12 (2y) l cccc 5U(i'TAItUint6MESTRY ]NRATIVE cc o rt ooc ccc: c t < c c c, v G C r.. c L cccCc GCVL c t • o c occc: cc o a cctc: v G .. ,. L GCVL Forte Software Operator Job Notes Barry Mouseal BLR. Inc )6-3700 banyh Barry houseal(iggm ail com 2/15/2019 11:56:21 AM Forte v5.4, Design Engine: V7.1.1.3 Page 1 of 1