Loading...
HomeMy WebLinkAboutS2019-0019 - MiscContinuous Inspection & Materials Testing SOUTHWEST 000000000000000 Inspection & Testing, Inc. 441 Commercial Way, La Habra, CA 90631-6168 (562)941-2990 - (714)526-8441 FAX (562)946-0026 FIELD DATA ON TEST SPECIMENS S'201-001 62210u�r;gge� ®r --- ASTM C31, C138, C143, C172, C173, C231, C1064 --- CONCRETE: MORTAR: SHOTCRETE: X CORES: GUNITE: ADDRESS: 1221 OUTRIGGER DR. C.DEL MAR JOB #: DATE: 03/20/2019 JOB NAME: SALOMON RESIDENCE PERMIT #: S2019-0019 ISSUED BY: NEWPORT BCH ARCHITECT: ENGINEER: POOL ENGINEERING INC. CONTRACTOR: MASTERPIECE SUB: C & J GUNITE & SHOTCRETE INC. LOCATION IN STRUCTURE: POOL AND SPA TRACT: PHASE: LOT #: CONCRETE SUPPLIER: GARY BALE PLANT: IRVINE MIX #: 1468SC TYPE OF CEMENT: II / V ADMIXTURE: 3/8 SC TICKET M 287218 SLUMP: 2.00 in. WATER ADDED: 0 gal. AIR TEMP: 59 F CONCRETE TEMP: 68 F MIXING TIME: TIME CAST: 11:45 DATE CAST: 02/20/2019 RECEIVED AT LAB: 02/25/2019 SPECIMENS MADE BY: ED SAHDALA / C. BROWN SPECIFIED PSI @ 28 Days: 2500 LAB M 135890 CLIENT: ED SAHDALAS INSPECTION TESTING INFORMATION: SAMPLE IDENTIFICATION: 1803124 1803125 1803126 AGE DAYS: 28 28 28 DATE TEST: 03/20/2019 03/20/2019 03/20/2019 SIZE (in.): Height X Diameter 8.000 X 4.000 8.000 X 4.000 8.000 X 4.000 AREA (in.A): 12.57 12.57 12.57 CRUSH LOAD (lbs.): 73562 72541 73173 COMPRESSIVE STRENGTH (psi.): 5850 5770 5820 HEIGHT -DIAMETER RATIO: CORRECTION FACTOR: CORRECTED STRENGTH (psi.): BREAK TYPE: III I III C.T.M. USED: Forney96 Forney96 Forney 'REMARKS: ASTM C39, C174, C192, C470, C617, C42 COMPLIES: X DOES NOT COMPLY: FOR INFORMATION: THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC. SAMPLES CAST BY OTHERS: RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING NOTICE:These test results are from samples cast by inspectors or technicians not employed by our firm. They were either delivered to our laboratory or picked up by our driver. We will accept no responsibility for the inspection made on the jobsite by the inspector, furthermore we ZAFAR AHM do not take responsibility for any information on this PRINCIPAL NEER report other than the strength as tested and reported. ASTM C39 BREAKS: [=CONE - ll=CONE AND SPLIT - III=COLUMNAR - IV=SHEAR - V=SIDE FRACTURES - VI=POINTED Project �a ! Report of Special Inspection Address � � -- 1; nSpG060r, 4 ype(s a 11 ✓' _ e t 8, c r ._ , r .. . jrfspsCtz Yti ate '`>� 2 C�o € G Teri rT3c f antirruoug Deicribe ittSVCzdart made, irsTud. v rtattons: f 4-. i J J " Made:<� �' i '' �ro G _ sw"'t_.J:: 1 < �- ,���..•i,L-^WG�r. T,,AI-Inssprrs4Ion'i Time Fach Y List Teams Rcgrr'rt`ing Cgr*tct rin, include uncarrected ga." pmvioudy listed To the best OrMy-Reno ledge; tte wark Inspected was ir, acrOrdart awftit �iie OUiiding hsps °ttt"taN approved design drswftrgs, speci:isat oni and appfitaWe warktr'sans3 ip provistOng Of the EiZC- exaept its, noted a .. vc f'e°^ fV Date �t�til3i;i 2'MY,�rs 4wr i�1/r�{:90✓',i'_ f C.'��F'_,✓tj'd..:' i4.r.,�rmte#�ltttae iIlf 1 � ".�. FORM et^sai9it sz01q 001G C22100rt53er Dr DL Acoustics 14301 Middletown Lane Westminster, CA 92683 Research &COnsti*lgitAcoushics Voice/Fax 714.373.3050 dlubman@dlacoustics.com October 7, 2019 Homeowner 20272 Bayview Ave. Newport Beach, CA, 92660 Report emailed to: daveleeseconcrete@hotmail.com Pool and or Spa Noise report for residence at 20272 Bayview Ave., Newport Beach, CA Dear Homeowner: At about 10:30 a.m. Monday, October 7, 2019 1 measured the pool and or spa equipment noise at your nearest neighbor's residence to test for compliance with the Newport Beach noise regulation (10.26.025). Newport Beach Residential Noise Standard For Noise Zone 1 (residential) the N. B. regulation's daytime noise level standard (maximum noise level from 10 p.m. to 7 a.m.) is 55 dBA — corrected for ambient noise. The nighttime noise standard (max noise level from 7 a.m. to 10 p.m.) is 50 dBA. The measurement is corrected for ambient noise and rounded to the nearest decibel as shown below. I am pleased to report that measured pool and or spa apparatus noise meets the Newport Beach noise standard for 24-hour use. Pertinent details of my findings are reported below. Locations and values of daytime noise measurements Uncorrected pool and or spa noise + ambient noise measured at property line: 49.70 dBA Ambient noise level measured at this location: not needed Pool and or spa equipment noise corrected for ambient noise: not applicable Pool and or spa equipment noise rounded to the nearest decibel: 50 dBA 50 dBA (Pass for 24 hour use) The currently installed pool and or spa apparatus noise of 50 dBA meets the Newport Beach noise code for both "daytime" use (7 a.m. to 10 p.m.) and "nighttime" use (10 p.m. to 7 a.m.), since the noise corrected for ambient does not exceed 50 dBA. If you have any questions about this report, please do not hesitate to contact me at (714) 373- 3050 or by email at dlubmankDdlacoustics.com Sincerely yours, f" L twull David Lubman, FASA, FINCE Acoustical Consultant Orange County Certification #200524 S2019-0014 1921004rt0gyer Dr October 7. 2019 APPENDIX A: Measurement Instrumentation Equipment The acoustical equipment used in the performance of this test is in accordance with ASTM and ANSI (American National Standards Institute) requirements. Key elements are as follows: Critical sound measuring instruments (sound analyzer, calibrator, and microphone) are annual calibrated by an independent NAVLAP certified laboratory. The most recent calibration was on 07/31/19. All calibration documents are available for inspection upon request. Critical instruments employed were: Bruel & Kjaer — Type 2270 Type I Precision Sound Analyzer SN # 3002720 Bruel & Kjaer - Type 4189 microphone, SN # 2850866 Bruel & Kjaer — Type 4231 Field Sound Calibrator, SN # 2588671