Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
X2019-4143 - Misc
STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCI-LTI-01-E (Revised 01/201 x Zo 6151— 9143 0 l 9 Play S o fie, W, CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-01-E Indoor Lighting (Page 1 of 2) Pr*&Neme. Bayside 175 EW.Iu.1 MAg.nry City of Newport Beach Pef"R201§4143 Pmjed Addrea: 1111 Bayside Dr. OY: Corona Del Mar na code: 92625 GENERAL INFORMATION DATE OF BUILDING PERMIT: PERMITp X2019-4143 BUILDING TYPE Nonresidential ❑ High -Rise Res (Common Area) ❑ Hotel/Motel (Common Area) T-10 PHASE OF CONSTRUCTION 13 New Construction 11 Addition ®Alteration 13 unconditioned SCOPE OF RESPONSIBILITY Enter the date of approval by enforcement agency of the Certificate of Compliance that provides Date: the specifications for the energy efficiency measures for the scope of responsibility for this 5/5/20 Installation Certificate. 5/5/20 In the table below identify all applicable construction documents that specify the requirements for the scope of responsibility reported by this Installation Certificate (continued). Document Title or Description Applicable Sheets or Pages, Tables, Schedules, etc. .Date Approved By " the Enforcement Agency Schedules E-0.1 5/5/20 Lighting Plan E-1.0 5/5/20 Title 24 E-3.0 5/5/20 Title 24 E-3.1 5/5/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance January 2020 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCI-LTI-01-E Revised 01/20 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-01-E Indoor Lighting (Page 2 of 2) Project Mnree Bayside 175 gnroreement Agency' City Of Newport Beach Perml lr9-4143 edAddress: 1111 Bayside Dr. "9 Corona Del Mar ziPcode: y2625 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: James HICKS Documentation Author Sign Documentation Author Company Name: William's Electric Inc. Date Signed: 6/1 Address: 833 W. 17th St. #2 CEA Certification Identification (If applicable): City/State/Zip: Costa Mesa, Ca. 92627 "hone: 949-650-4703 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 5. 1 will ensure that a completed signed copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: James HICKS Responsible Builder/Installer Signature: _. Company Name: (Installing Subcontractor or General contractor or Builder/Owner) Position With Company (Title): William's Electric Inc. Address: 833 W. 17th St. #2 CSI B License: 554799 City/State/Zip: Costa Mesa, Ca. 92627 Phone 949-650-4703 Date signed: 6/17/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance January 2020 STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM OR LIGHTING CONTROL SYSTEM CEC-NRCI-LTI-02-E Revised 01/20 CALIFORNIA ENERGY COMMISSION Is CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System of 1) (Page 1 Prnled Name: Bayside 175 Enfo"ement Agenq: City Of Newport Beach "`MT!414143 Project Address: 1111 Bayside Dr. C": Corona Del Mar zm C.d.: 92625 GENERAL INFORMATION DATE OF BUILDING PERMIT: PERMIT# X2019-4143 11 High -Rise Res (Common BUILDING TYPE ® Nonresidential ❑Hotel/Motel (Common Area) Area) PHASE OF ❑ New Construction ❑ Addition ® Alteration ❑ Unconditioned CONSTRUCTION SCOPE OF RESPONSIBILITY Enter the date of approval by enforcement agency of the Certificate of Compliance that provides the specifications for the energy efficiency measures for the scope of responsibility for this Installation Certificate. Date: 5/5/20 Requirements in the Standards: §130.4(b) Before an Energy Management Control System (EMCS), or Lighting Control System can be recognized for compliance with the lighting control requirements in Part 6 of Title 24, the person who is eligible under Division 3 of the Business and Professions Code to accept responsibility for the construction or installation of features, materials, components, or manufactured devices shall sign and submit this Installation Certificate. If any of the requirements in this Installation Certificate fail the Energy Management Control System or Lighting Control System installation requirements, these options for controlling lighting shall not be recognized for compliance with the Building Energy Efficiency Standards. Check all that apply: PART 1 What type of Lighting Control System has been installed? ❑ A. Energy Management control System (EMCS) - Is an automated control system that regulates the energy consumption of a building by controlling the operation of energy consuming systems, and is capable of monitoring loads, and adjusting operations in order to optimize energy usage and respond to demand response signals. ❑ The Energy Management Control System is installed to function as a lighting control required by Part 6 and its functionally meets all applicable requirements for each application for which it is installed, in accordance with Section 110.9, 130.1, 130.4, 130.5, 150.0(k), and 150.2, and complies with Nonresidential Appendix NA7.7.2. ® B. Lighting Control System - Requires two or more components to be installed in the building to provide all of the functionality required to make up a fully functional and compliant lighting control. p The installed Lighting Control System is installed to comply with applicable requirements in Section 110.9, 130.2, 130.4, 150.0(k), and 150.2, and complies with Reference Nonresidential Appendix NA7.7.2. CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance January 2020 P STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM CEC-NRCI-LTI-02-E Revised 01120 OR LIGHTING CONTROL SYSTEM CAI IFORNIA FNEROV COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System of 4) (Page 2 r'°1°°°N°'"°' Bayside 175 `"`°"" `"`ar°"� City of Newport Beach "°3F20}�'4143 Pr°1°°[Addren. 1111 Bayside Dr. °ty Corona Del Mar PART 2 Lighting Control Functional requirements: Check all that apply when verifying the installation of an EMCs or Lighting Control System. 12 A. All lighting controls and equipment have been installed in accordance with the manufacturer's instructions. ❑ B. All installed EMCS systems meet each respective lighting control for which it is installed for meeting requirements in Section 110.9, 130.1, 130.4, 150.0(k), and 150.2. Q C. Components of all installed lighting control systems meet applicable requirements in Section 110.9, 130.2, 130.4, 150.0(k), and 150.2. R] D. The EMCS or the lighting control system functions as time -switch lighting control checked below, and complies with all of the following requirements: © 1. The EMCS or the lighting control system functions as a time -switch control meets the requirements below: a. has program backup capabilities that prevent the loss of the device's schedule for at least 7 days, and the device's date and time for at least 72 hours if power is interrupted. b. Automatic time -switch controls installed in nonresidential buildings meet the following requirements: i. Is capable of providing manual override to each connected load and shall resume normally scheduled operation after manual override is initiated within 2 hours for each connected load; and ii. Incorporates an automatic holiday shutoff feature that turns off all connected loads for at least 24 hours and then resumes normally scheduled operation. 12 2. The EMCS or the lighting control system functions as an astronomical time -switch control meets the requirements below: a. Meets the requirements of an automatic time -switch control; b. Has sunrise and sunset prediction accuracy within plus -or -minus 15 minutes and timekeeping accuracy within 5 minutes per year; c. Is capable of displaying date, current time, sunrise time, sunset time, and switching times for each step during programming; d. Has an automatic daylight savings time adjustment; and e. Has the ability to independently offset the on and off for each channel by at least 99 minutes before and after sunrise or sunset. ❑ 3. Multi -Level Astronomical Time -Switch Controls, in addition to meeting all of the requirements for Astronomical Time -Switch Controls, includes at least 2 separately programmable steps per zone. ® E. The EMCS or the lighting control system functions as an automatic daylighting control meets the requirements below: 1. Automatically return to its most recent time delay settings within 60 minutes of the last received input when put in calibration mode; 2. Has a set point control that easily distinguishes settings to within 10% of full scale adjustment; 3. Provide a linear response within 5% accuracy over the range of illuminance measured by the light sensor; 4. Be capable of being calibrated in a manner that the person initiating the calibration is remote from the sensor during calibration to avoid influencing calibration accuracy; and CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance January 2020 STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM OR LIGHTING CONTROL SYSTEM CEC-NRCI-LT02-E Revised 01/20 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System of 4) (Page 3 Vroied Name: Bayside 175 `nf°rmmen` Agem� City of Newport Beach "eX2":4143 Pmie"Addressr 1111 Bayside Dr. °t" Corona Del Mar Z'"`odP192625 12 F. The EMCS or Lighting Control System functions as a dimming control and meet all of the requirements below: 1. Is capable of reducing power consumption by a minimum of 65% when the dimming is at its lowest level; 2. provides an off setting which produces a zero lumen output; and 3. Reduce flicker operation through the dimming range so that the light output has an amplitude modulation of less than 30% for frequencies less than 200 Hz without causing premature lamp failure. 4. (For system designed for use in three way circuits:) be capable of turning lights off, and to the level set by the dimming controls if the lights are off. ® G. The EMCS or the lighting control system functions as an occupant sensing control and meets all of the following requirements: 1. Is capable of automatically turning the controlled lights in the area either off or down no more than 20 minutes after the area has been vacated. 2. (For system with manually -on control features:) have a grace period of no less than 15 seconds and no more than 30 seconds to turn on lighting automatically after the sensor has timed out; and 3. Provides a visible status signal that indicates that the control is operating properly, or that it has failed or malfunctioned. The visible status signal may have an override switch that turns off the signal. PART 3 Requirements for which the control is being installed to complied with: Identify all requirements in the Standards for which the EMCS or Lighting Control System is installed to function as and complies with: Check all that are in compliance with the Standards, Section 130.1: ❑ A. Section 130.1(a) Area Controls Q B. Section 130.1(b) Multi -Level Lighting Controls 5d C. Section 130.1 (c) Shut -OFF Controls 1� D. Section 130.1 (d) Automatic Daylighting Controls ❑ E. Section 130.1 (e) Demand Responsive Controls ❑ F. Section 130.5 (d) Circuit Controls for 120 -Volt Receptacles Check all that are applicable and in compliance with the Standards: ❑ A. Residential garages with 8 vehicles or more per site: All lighting controls must comply with nonresidential indoor lighting control requirements in Section 130.1. ❑ B. Single -Family Building Indoor Lighting. ❑ All indoor lighting controls must comply with Section 150.0(k)2. ❑ Garages with less than 8 vehicles per site: The lighting control must comply with Residential indoor lighting control requirements in Section 150.0(k)21. ❑ C. Low -Rise Residential Building Indoor Lighting. ❑ All indoor lighting controls of the dwelling units must comply with Section 150.0(k)2. ❑ Garages with less than 8 vehicles per site: The lighting control must comply with one of the following: ❑ Residential indoor lighting control requirements in Section 150.0(k)21; ❑ Nonresidential indoor lighting control requirements in Section 130.1. ❑ Interior Common Area Lighting: CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance January 2020. STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM OR LIGHTING CONTROL SYSTEM CEC-NRCI-LTI-02-E Revised 01120 CALIFORNIA ENERGY COMMISSION is CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System of 4) (Page 4 PfOfe N° ej Bayside 175 r^'° "s°^°rCity of Newport Beach P9Cp019e4143 Pr°;°«Addr°,,: 1111 Bayside Dr. ""' Corona Del Mar nPc°ae:gp625 ® For common areas equals 20 percent or less of the total building floor area, the installed lighting must be controlled by occupant sensors. ® For common areas is greater than 20 percent of the total building floor area, the installed lighting control must comply with the applicable nonresidential lighting control requirements. Corridor and stairwell lighting must be controlled by occupant sensors. ❑ D. High -Rise Residential Building Indoor Lighting. ❑ All indoor lighting controls of the dwelling units must comply with Section 150.0(k)2. ❑ Garages with less than 8 vehicles per site: The lighting control must comply with nonresidential indoor lighting control requirements in Section 130.1. CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance January 2020 STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM OR LIGHTING CONTROL SYSTEM CEC-NRCI-LTI-02-E Revised 01/20 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System of 4) (Page 5 PfOf,dName Bayside 175 °r`em°"tAe°"`y'City of Newport Beach Pef7lr'PM 4143 Pf JectAddfess: 1111 Bayside Dr. city: Corona Del Mar ziPc°ae:92625 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: James HICKS Documentation Author natu Documentation Author Company Name: William's Electric Inc. Date Signe . 17/20 Address: 833 W. 17th St. #2 CEA Certification Identification (If applicable): City/State/Zip: Costa Mesa, Ca. 92627 Phone: 949-650-4703 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the Installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 5. 1 will ensure that a completed signed copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/installer Name: James Hicks Responsible Builder/installer Sign e', Company Name: (Installin Subcontractor or General Contractor or William's Electric Inc. Position with Comp�ny,l.T' el: PM Builder/Owner) Address: 833 W. 17th St. CSLB License: 554799 City/State/Zip: Costa Mesa, Ca. 92627 Phone 949-650-4703 Date Signed: 6/17/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance January 2020