Loading...
HomeMy WebLinkAbout20190628_PlansPA2019-130 3800 E. PCH 3800 & 381 O PCH / Corona Del Mar, CA 92625 , '?Sl 0 ~ . Costa Mesa ~·' • ./ ® Ill Hoao Hospital Newpon Beach N wport Beacl) J p i NfWPOIH ,l ClNTfR _/ ->' ,;,. 9•~'""" COR A DEL l.<AA ,. I r 3100 Ptclflc 0 S Co "HIQl>wt r lnsp ratoon Point S.,,.J ........ .., Bue~ Gully RPservP NfWPOIU COAST ' .. ,4 Crysra 7~ove S!are Park Sha<Jy Canyon Golf Cl ub Shaws cove. Laguna Beach §,I 0 11 W~low sragmgArea Top or the World~ (l aguna Bea<:h) Festival of Ans and Pageant of the Masters 0 Chlldre<f s M CD Vicinity Map 1r-------------------------------- Scale: NTS Job Name: 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep: Neil McNaught E-mail: NeilM @t ntelectricsign .com Designer : John Nauta Design Number : 19-06-3939 -ROO Scale : As Noted Original Date : 06/19/19 Revisions : Th is is an orig inal unpubli shed drawing created by TNT Electric Sign Co . II is submined for your approval. II is not to be shown to anyone outside of you r orga ni zation . nor is it to be reproduced . copied or exhibited in any lashion . The changing of co lors , sizes , materials or illumination me thod does not alter the design . Ownersh ip ol lhis design is held by TNT Electric Sign Co . Authorization to use this des ign in an y las hion must be obtained in writing from TNT Electr ic Sign Co. © TNT Electric Sign Co. 2019 Note : The colors depi cted here are a graphic representat ion . Actual colors may vary . See color spec ificat ions . Page: 1 of 11 PA2019-130 ~ en co 111 '-0" 40'-0" 40'-0" CD Plot Plan 1 r-.;:sc=a~le~:~nt~s-------------------------------------------------- D D Job Name: 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep: Neil McNaught E-mail: NeilM @tntelectricsign .com Designer : John Nauta Design Number: 19-06-3939-ROO Scale : As Noted Original Date : 06/19/19 Revisions : This is an orig ina l unp ublished drawing crea ted by TNT El ec tric Sign Co . It is submitte d for yo ur approval. It is not to be shown to anyone outsi de of your organizatio n, nor is it to be reproduced, copie d or ex hibi ted in any fashio n. The changin g of colors, sizes , materia ls or illumination method does not alter the design. Ownershi p of this desig n is he ld by TNT Electric Si gn Co . Aut horizatio n to use this desi gn in any fas hion mu st be obtai ned in wri ting fro m TN T Elect ric Sign Co . ©TNT Electric Sign Co . 2019 Note : The co lors depic ted he re are a grap hic re prese nt ati on. Actua l co lors may vary. See col or speci fica tions. Page: 2 of 11 PA2019-130 ('-;;\ South Elevation -3800 Building 0f---------- Cl ,- ' C") CD South Elevation -3800 Building 1 f---~~~-----'--~~~ Scale: 1.1.i" = 1 '-0" Note: Field verify all dims prior to fab 1'-6" X 18'-0" 2'-0" x 10 '-0 " Cabinet 2'-0 " x 10'-0" Cabinet Job Name: 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep: Neil McNaught E-mail: NeilM @tntelectricsign.com Designer: John Nauta Design Number : 19-06-3939-ROO Scale : As Noted Original Date: 06/19/19 Revisions: Th is is an original unpublished drawing created by TNT Electric Sign Co . It is submitted for your approval . It is not to be shown to anyone outside of your organ iza tion , nor is it to be reproduced , copied or exhibited in any fashion . Th e changing of colors , si zes , materials or illumination method does not alter the design . Ownershi p of this design is held by TNT Electric Sign Co . Author izatio n to use this design in any fas hion must be obtained in writing from TNT Electr ic Sign Co . © TNT Electric Sign Co . 2019 No te: The colors depict ed here are a graphic representat ion . Actual colors may vary. See color specifications . Page: 3 of 11 PA2019-130 40 '-0 " Franta e 1 '-6 " X 18 '-0" 0 South Elevation -3810 Building 2 ____ ...c.__ __ ,---------------------------,---------------------.J,-------......,-- CD South Elevation -381 O Building 1 !---------- Scale: 114'' = 1'-0" 1'-6 " X 12 '-0 " Job Name: 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep : Neil McNaught E-mail : Nei lM @tnt ele ct ricsig n.c om Designer: John Naut a Design Numb er: 19 -06-3939 -ROO Sc ale : As Noted Original Da te: 06/19 /19 Revisions : Th is is an original unpublished drawing crealed by TNT Eleclric Sign Co . II is submined for your approval. II is nol to be shown lo anyone outside of your organizalion . nor is ii to be reproduced , copied or exh ibited in any fashion . The changing of colors , sizes . malerials or illumina ti on melhod does nol alter lhe design . Ownership of this design is held by TNT Eleclric Sign Co . Authorization to use this des ign in any fashion mus! be oblained in writ ing from TNT Electr ic Sign Co . © TNT Electr ic Sign Co . 2019 Nole : The colors depicted here are a graphic represenlal ion . Aclual colors may vary . See co lor spec ifications . Page: 4 of 11 PA2019-130 Note: Field verify all dims prior to fab 0 West Elevation -3800 Building 2 f---------- Scale: nts 2'-0" x 10'-0" Cabinet 8'-0" x 8'-0" Cabinet CD West Elevation -3800 Building 1 ------- Sc a I e: Vii" = 1 '-0" Job Name: 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep: Neil McNaught E-mail: NeilM@tntelectricsign .c om Designer: John Nauta Design Number : 19-06-3939-ROO Scale : As Noted Original Date : 06/19/19 Revisions : This is an original unpublished drawing created by TNT Electric Sign Co . It is submi«ed foryourapproval. It is not to be shown to anyone outside of your organization , nor is it to be reproduced , copied or exhibited in any fashion . The changing of co lo rs , sizes , materials or illumination method does not alter the design . Ownership of this design is held by TNT Electric Sign Co . Authorization to use this des ign in any fashion must be obtained in writ ing from TNTElectric Sign Co . © TNTElectric Sign Co. 2019 Note : The colors depicted here are a graphic representat ion . Actual colors may vary. See co lo r specifications . Page: 5 of 11 PA2019-130 Note: Field verify all dims prior to fab 0 West Elevation · 3800 Building 2 1----------2'-0" x 10'-0" Cabinet 2'-0" x 10'-0" Cabinet - CD West Elevation -3800 Building 1 !----------- Scale:%"= 1'-0" Job Name : 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep: Neil McNaught E-mail: NeilM@tntelectricsign .c om Designer : John Nauta Design Number : 19-06-3939-ROO Scale: As Noted Original Date : 06/19/19 Revisions : This is an original unpublished drawing created by TNT Electric Sign Co . It is submitted for your approval. It is not to be shown t o anyone outside of your organization, nor is it to be reproduced, copied or exhibited in any fashion . The changing of colors , sizes , materials or illumination method does not alter the design . Ownership of this design is held by TNT Electric Sign Co . Authorization to use this des ign in any fashion must be obtained in writing from TNT Electric Sign Co . ©TNT Electric Sign Co. 2019 Note : The co lors depicted here are a graphic representat ion . Actual colors may vary. See color spec ificat ions . Page: 6 of 11 PA2019-130 40'-0" Fronta e Note: Field verify all dims prior to fab 2'-0" x 10'-0" Cabinet 0 South Elevation -3810 Building 2 1---------'------- Scale: nts 2'-0" x 10'-0 " Cabinet CD South Elevation -3810 Building 1 !---------- Scale: 1/.t" = 1'-0" Job Name: 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep: Neil McNaught E-mail: NeilM@tntelectricsign .com Designer : John Nauta Design Number : 19-06-3939-ROO Scale: As Noted Original Date : 06/19/19 Revisions : Th is is an original unpubli shed dr aw ing created by TNT Electric Sign Co . It is submitted for your approval. It is not to be shown to anyone outside of your organization . nor is it to be reproduced . copied or exh ibited in any fashion . Th e changing of colors, si zes , material s or illuminatio n method doe s not alter the design. Ownership of this design is held by TNT Elec tric Sign Co . Aut hor ization to use th is des ign in any fas hion must be obtained in writ ing from TNT Electr ic Sign Co . ©TNT Electric Sign Co . 2019 Note : The colors depicted here are a graphic representat ion . Actual colors may vary. See color spec ifications . Page: 7 of 11 PA2019-130 18'-0" W Sign Elevation Layout Square Footage: 27 A l----=------''---------------'-------=---------a 1y: Two (2) Required Scale: 1h" = 1'-0" Manufacture and install interior illuminated cabinet sign Cabinet: Face: Copy: Returns: Illumination: Note: Interior illuminated cabinet Routed out aluminum painted black 1h'' thick push through white acrylic 5" deep aluminum painted black, clean backs White LEDs/ power supplies mounted internally Field verify all dims and conditions prior to fab 120-277VAC J-box 1 %''Alum.sq. tube ----- bolted to cabinet 120-277VAC ----1-.._ disconnect switch Grounding wire secured to grounding screw -----i Soflil wall Counter sunk screws Aluminum retainers Routed out aluminum Interior alum. sq. tube frame Light Emitting Diods (LED) Low voltage wire lrom LED lo LED Aluminum backs Push through acrylic 120-277VAC disconnect switch Grounding wire/ screw Self contained power supply Secondary class 2 low voltage wires (no conduit required) CD Typical Section detail 1 ~~~~~~~~ Scale: nts ALL ELECTRICAL COMPONENTS ® LISTED • Control for All Signs. All Signs with permanently connected lighting shall meet the requirements of Section 133 . • Automatic Time Switch Control. All signs with permanently connected lighting shall be controlled with an automatic time switch that complies with the applicable requirements of Section 1198 . • Photocontrol or outdoor astronomical lime switch control. All outdoor signs shall be controlled with a photocontrol or outdoor astronomical time switch unless exempted from the exceptions . See Section 133(a)2. • Dimming. All outdoor signs shal l be controlled with a dimmer that provides the ability to automatically reduce sign power by a minimum of 65 percent during nighttime exempted from the 5 possible exceptions. See Section 133(a)3 . • Demand Responsive Electronic Message center Control (EMC), newly connected lighting power load greater than 15kW shall have a control installed that is capable of reducing the lighting power by a minimum of 30% when receiving a demand response signal that is sent out by the local utility. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/ or other applicable local codes. This includes proper grounding and bonding of the sign . All wall penetrations to be sea led with UL Li sted silicone sea lant. In th e utilization of GFI Transformers and in accordance with NEC and UL Listed guidelines , it is required that primary circuits to each sign must have dedicated circuits with proper ground from main panel and must be bonded. Any equipment or lighting that is added/ shared to the primary sign circuit will cause GFI transformers to trip off. Neutral to ground should not exceed 3 volts to prevent GFI from tripping . Job Name: 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep: Neil McNaught E-mail: NeilM@tntelectricsign.com Designer : John Nauta Design Number: 19-06-3939-ROO Scale: As Noted Original Date : 06/19/19 Revisions: This is an original unpublished draw in g created by TNT Electric Sign Co . It is submitted for your approval. It is not to be shown to anyone outside of your organization. nor is it to be reproduced , copied or exhibited in any fashion . The changing of co lo rs . sizes . materials or illumination method does not alter the design . Ownership of this design is held by TNT Electric Sign Co . Authori zation to use th is des ign in any fas hi on must be obtained in writing from TNT Electric Sign Co . © TNT Electric Sign Co. 2019 Note : The colors depicted here are a graphic representat ion . Actual colors may vary. See color spec ifications . Page: 8 of 11 PA2019-130 9 N 10'-0" [[] Sign Elevation Layout Square Footage: 16.5 B ~-___::_------------=----=--- Qty: Two (2) Required Scale: W' = 1 '-0" Manufacture and install interior illuminated cabinet sign Cabinet: Face: Copy: Returns: Illumination: Note: Interior illuminated cabinet Routed out aluminum painted black W' thick push through white acrylic 5" deep aluminum painted black, clean backs White LEDs/ power supplies mounted internally Dims okay per N.M. 12'-0" TENANT W Sign Elevation Layout Square Footage: 16.5 C --=----=--------__:_ _ __c.__ Qty: Two (2) Required Scale: W' = 1'-0" Specifications same as sign A Note: Dims okay per N.M. Counter sunk screws ----- Aluminum retainers Routed out aluminum Interior alum. sq. tube frame Light Emitting Diods (LED) ----i---+--~ Low voltage wire -+-+-------11.i 111 from LED to LED Aluminum backs -+-+------ 120·277VAC J·box -1-+---, Push through acrylic 120·277VAC --+---+-~ disconnect switch Grounding wire/ screw Self contained power supply Secondary class 2 low voltage wires (no conduit required) %" weep holes W' through bolts Flex conduit 3/8" lag bolts --+-----~ or as required per field conditions (D Typical Section detail Scale: nts I 1 Y," X 1/8" Alum. angle brackets ALL ELECTRICAL ® COMPONENTS LISTED • Control for All Signs. All Signs with permanently connected lighting shall meet the requirements of Section 133. • Automatic Time Switch Control. All signs with permanently connected lighting shall be controlled with an automatic time switch that complies with the applicable requirements of Section 1198. • Photocontrol or outdoor astronomical time switch control. All outdoor signs shall be controlled with a photocontrol or outdoor astronomical time switch unless exempted from the exceptions. See Section 133(a)2 . • Dimming . All outdoor signs shall be controlled with a dimmer that provides the ability to automatically reduce sign power by a minimum of 65 percent during nighttime exempted from the 5 possible exceptions. See Section 133(a)3. • Demand Responsive Electronic Message center Control (EMC), newly connected lighting power load greater than 15kW shall have a control installed that is capable of reducing the lighting power by a minimum of 30% when receiving a demand response signal that is sent out by the local utility. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/ or other applicable local codes. This includes proper grounding and bonding of the sign. All wall penetrations to be sealed with UL Listed silicone sealant. In the utilization of GFI Transformers and in accordance with NEC and UL Listed guidelines , it is required that primary circuits to each sign must have dedicated circuits with proper ground from main panel and must be bonded. Any equipment or lighting that is added/ shared to the primary sign circuit will cause GFI transformers to trip off . Neutral to ground should not exceed 3 volts to prevent GFI from tripping. Job Name: 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep: Neil McNaught E-mail: NeilM@tntelectricsign.com Designer : John Nauta Design Number: 19-06-3939-ROO Scale: As Noted Original Date: 06/19/19 Revisions : This is an original unpublished draw ing created by TNT Electric Sign Co . It is submitted for your approval . It is not to be shown to anyone outside of your organization , nor is it to be reproduced, copied or exhibited in any fashion. The changing of colors . sizes . materials or ill umination method does not alter the design . Ownership of this design is held by TNT Electric Sign Co . Authorization to use this des ign in any fashion must be obtained in writing from TNT Electr ic Sign Co . © TNTElectric Sign Co. 2019 Note : The colors depicted here are a graphic representat ion . Actual colors may vary. See color spec ifications. Page: 9 of 11 PA2019-130 9 N D Sign Elevation Layout Qty: Five (5) Required Manufacture and install single face illuminated cabinet sign Cabinet: Face: Copy: Returns: Illumination: Note: Interior illuminated cabinet sign painted Matthews black .080 routed out aluminum painted Matthews Black %" thick push through white acrylic 3" deep aluminum painted Matthews Black White LEDs/ self-contained power supplies Dims okay per N.M. Note: Field verify all dims prior to fab Square Footage:20 Scale: 1h" = 1 '-0" CD Typical Section detail 1 ~~~~~~ Scale: nts Counter sunk screws Aluminum retainers Routed out aluminum Interior alum . sq . tube frame Light Emitting Diods (LED) Low voltage wire from LED to LED Aluminum backs 120-277VAC J-box Push through acrylic ~-+-+--120-277VAC disconnect switch --+-----+--+---Grounding wire/ screw Sell contained power supply Secondary class 2 low voltage wires (no conduit required) W' weep holes 3/8" lag screws Flex conduit ALL ELECTRICAL COMPONENTS ® LISTED • Control for All Signs. All Signs with permanently connected lighting shall meet the requirements of Section 133. • Automatic Time Switch Control. All signs with permanently connected lighting shall be controlled with an automatic time switch that complies with the applicable requirements of Section 1198. • Photocontrol or outdoor astronomical time switch control. All outdoor signs shall be controlled with a photocontrol or outdoor astronomical time switch unless exempted from the exceptions . See Section 133(a)2 . • Dimming. All outdoor signs shall be controlled with a dimmer that provides the ability to automatically reduce sign power by a minimum of 65 percent during nighttime exempted from the 5 possible exceptions . See Section 133(a)3 . • Demand Responsive Electronic Message center Control (EMC), newly connected lighting power load greater than 15kW shall have a control installed that is capable of reducing the lighting power by a minimum of 30% when receiving a demand response signal that is sent out by the local utility. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/ or other applicable local codes . This includes proper grounding and bonding of the sign. All wall penetrations to be sealed with UL Listed silicone sealant. In the utilization of GFI Transformers and in accordance with NEC and UL Listed guidelines, it is required that primary circuits to each sign must have dedicated circuits with proper ground from main panel and must be bonded. Any equipment or lighting that is added/ shared to the primary sign circuit will cause GFI transformers to trip off. Neutral to ground should not exceed 3 volts to prevent GFI from tripping. Job Name: 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep: Neil McNaught E-mail: NeilM@tntelectricsign.com Designer: John Nauta Design Number: 19-06-3939-ROO Scale: As Noted Original Date : 06/19/19 Revisions: This is an original unpublished draw ing created by TNT Electric Sign Co. It is submitted for your approval. It is not to be shown t o anyone outside of your organization , no r is it to be reproduced , copied or exhibited in any fashion . The changing of colors . si zes , materials or illumination method does not alter the design . Ownership of this design is held by TNT Electric Sign Co . Authorization to use this design in any fashion must be obtained in writing from TNT Electr ic Sign Co . © TNT Electric Sign Co. 2019 Note : The colors depicted here are a graphic rep resentation . Actual colors may vary. See color specificat ions . Page: 10 of 11 PA2019-130.. 1'-01/8" 8'-0" SWEAT SAUNA> FACIAL LOUNGE > THE HYDRATION ROOM A BOTANICA FLORAL > AURA PILATES A GABRIEL'S TAILORING A WELL> PAZ INGREDIENTS A LEASING INFORMATION: 949. 723.2050 .080 alum. routed aluminum tenant panel with push through copy %" thick acrylic push through acrylic ----+--------.i .080 routed out aluminum tenant panels -------if------------.1µ Studs welds behind each tenant panels ---+-----------.111- and bolted to .125 routed out aluminum _ ____,,__ _______ ___,~ main panel background (to hold individual tenant panels) Wall surface ------------ [TI Sign Elevation Layout E f-----------'------------ Qty: One (1) Required Scale: W' = 1 '-0" CD Side View 1.-------- Scale: Yi"= 1 '-0" ® Close Up View Detail 2 1---------'----- Scale: 1 Yi"= 1'-0" Reface existing panel face Cabinet: Tenant Panel: Copy: Returns: Illumination: Note: Existing, to remain as is Routed out .080 aluminum painted to match Matthews Black %" thick push through white acrylic Existing, to remain as is Existing, to remain as is Dims per original plans Job Name: 3800 E. PCH Sign Program Address: 3800 & 3810 PCH Corona Del Mar, CA 92625 Sales Rep: Neil McNaught E-mail: NeilM@tntelectricsign .com Designer: John Nauta Design Number : 19-06-3939-ROO Scale : As Noted Original Date: 06/19/19 Revisions : Th is is an original unpublished drawing created by TNT Electric Sign Co . It is submitted for your approval. It is not to be shown t o anyone outside of you r organization , nor is it to be rep roduced , copied or exh ibit ed in any fashion . The changing of colo rs, si zes , materials or ill umination method does not alter the design . Ownership of this design is held by TNT Electric Sign Co. Authori zation to use this design in any fashion must be obtained in writing from TNT Electr ic Sign Co . ©TNT Electric Sign Co. 2019 Note : The color s depicted here are a graphic representat ion . Actu al colors may vary. See color spec ificat ions. Page: 11 of 11