HomeMy WebLinkAboutF2021-0212 - CalcsHYDRONICS: RESIDENTIAL FIRE SPRINKLER fDOU'IC0S 1 1121Lo1,99� U, ENGINEERS : FIREGUARD SPRINKLER ADDRESS 10131 SYSTEMS. (714) 310-0194, Cabo Drive, Westminster, CA 92683. LICENSE : C16-992002 DESIGNER : Fireguard Sprinkler Systems, Inc. DATE : 05-26-2021 FILE, GALLOWAY JOB NAME Galloway Residence LOCATION 1227 Outrigger Drive DESIGN DATA. DESIGN CRITERION: MIN SPR FLOW : AREA PER SPRINKLER TOTAL CALCULATED AREA TOTAL SPRINKLERS CALCULATED FLOW DATA. TOTAL SPRINKLER FLOW DOMESTIC DEMAND : TOTAL WATER REQUIRED BASE OF RISER NODE FLOW PRESS NFPA 13D 2016 EDITION REMOTE AREA #1 13 Gpm 256 Sq Ft 512 Sq Ft 2 2 6. 0 Gpm 5.0 Gpm 31.0 Gpm BR 31.0 Gpm 29.8 Psi AUTHORITY HAVING JURISDICTION : NewportBeach Fire Department PHONE : 949-644-3309 NKLER HYDRAULIC HYDRONICS: RESIDENTIAL FIRE SPRIS5.7 - SUBMITTAL. Page 1 ENGINEERS FIREGUARD SPRINKLER SYSTEMS. (7C4A)9216830194. ADDRESS 10131 Cabo Drive, Westminster, Date: 05-26-2021 File: C:\RESDEN57\GALLOWAY.RES JOB : Galloway Residence SPRINKLER MANUF : SENJU - RC -RES, 16x16, K=4.9, P=7 DESIGN IRC MODEL -RES GPM/Sq Ft VALVE 0.0 Psi Ft DENSITY 0.05 0 Sq Ft DESIGN AREA 512 Sq AREA / SPR 25 METER 4.0 Psi � SPRINKLER 4 13.0 GPM PIPES 15 NODES ' 15 RESIDUAL 20 psi FLOW 1000 Gpm SOURCE STATIC : 58 Psi K -FACTOR PRESSURE DISCHARGE NODE ELEVATION Psi GPM NO. Feet ----------------- --------------------------- 14.00 ----------- 4.90 7.0 13.0 13.0 1 2 14.00 4.90 7.0 8.9 3 14.00 8.9 4 14.00 17.1 5 14.00 17.1 6 14.00 17.1 7 14.00 17.1 8 14.00 18.4 9 14.00 20.4 14.00 RR 7.50 29.8 5.0 DOME BR 4.00 33.1 UG -2'50 35.3 WM -2'50 -2.50 SOURCE 46.3 SR SPRINKLERS FLOWING 2256 Sq Ft AREA PER SPRINKLER 512 Sq Ft TOTAL DESIGN AREA MIN SPRINKLER FLOW 13 Gpm 0.051 Gpm/Sq Ft REQUIRED DENSITY 0.051 Gpm/Sq Ft COMPUTED DENSITY TOTAL SPRINKLER FLOW 26.0 5.0 Gpm GPM TOTAL DOMESTIC FLOW 31.0 GPM TOTAL WATER REQUIRED TOTAL SPRINKLER PRESS 2.3 42.3 Psi Psi WATER METER LOSS 0.0 psi Copyright (2009) VALVE FIXED LOSS by SUPPLY PRESS AVAILABLE 57 7 5.9 3 Psi Psi Hydronics Engineering Suite 609 DEMAND PRESS REQUIRED 11.6 Psi 34119 Fremont Bl, 94555 PRESSURE CUSHION Fremont, Ca., (800) 845-9819 11.4 FIS MAXIMUM VELOCITY HYDRONICS: RESIDENTIAL FIRE SPRINKLER ENGINEERS HYDRAULICS 5.7 - SUBMITTAL. Page ADDRESS FIREGUARD SPRINKLER SYSTEMS. 10131 Cabo 2 (714) 310-0194. Date: 05-26-2021 Drive, Westminster, File: CA 92683. C:\RESDEN57\GALLOWAY. JOB : Galloway Residence RES PIPE BEG FLOW N0. K -FACTOR GPM LENGTH C -FACTOR END FITTING TYPE FTG FRI-LOSS PRESSURE ---- ___ --------- ---- -----DIAMETER TOTAL (Psi) ( Psi /Ft ) I q= 13.0 K= 4.900 L=4.9 --------- Q= 13.0 F= B3L F= Vel= 6.9 15.0 C_ Pt___7.0 Pt___7.0 - 150 3 D= 0.879 TL= Pe 0.0 Pv -0.3 19.9 0.0943 --------------- Pf 1.9 Pn 6.7 2 --------------- Pt 8.9 ------------ 2 q= 13.0 K- 4.900 L= ------------------------ Ve4_ 13.0 F= B3L F= 6.9 15.0 C- 150 Pt 7•P pt 7 4-------------------------------------------- D= 0.874 TL= Pv 3 19.9 0.0943 Pe 0- -0. Pf 1.9 Pn 6.7 Pt 8.9 3 q= 0.0 K= 0.000 L= Q= ------------------------- 12.3 0.0 F= F= Vel= 0.0 Pt 8.9 Pt 8.9 12.0 C= 4 D= 1.101 TL= 1.10 Pe 0.0 Pv 0.0 .0 24.3 0.0000 --------------------8.9 Pf 0.0 Pn 3 -------------------------------------------- t 8.9 q q= 0.0 K= 0.000 L= Q= 123.2 ---'--'-- 13.0 F= 12R2B32L Pt 8.9 Pt 8.9 Vel= 4.4 D= 1.101 TL= 182.0 C= 150 Pe 0.0 Pv -0.1 305.2 ---4------------------- 0.0309 Pf 9.4 Pn 8.8 ------ Pt 18.4 ------- 5 q= 0.0 K= 0.000 L= Q= -------------------____-___ 96.1 12.9 F= 11R4B28L Pt 8.9 Pt 8.9 8 Vel=9F= .9 D= 1.101 TL= 171.0 C= 150 Pe 0.0 Pv -0.1 ----------------------- 267.1 0.0304 Pf 8.1 Pn8.8 g --------------------------------- t 17.1 6 q- 0.0 K= 0.000 I= ------------------ -----_ Q= 12.9 F= 3R4L F= Vel= Pt 17.1 Pt 17.1 23'0 C= 9 4.4 D= 1.101 TL= 150 Pe 0.0 Pv -0.1 42.3 0.0304Pf --------------------- 1.3 Pn 17.0 --------13.9---- Pt 18.9 4= 0.0 K= 0.000 L= 4= __ 13.9 ----_-Pt 0.0 F= R9L F= Vel= 0.0 17.1 pt 17.1 17.0 C= 150 7 D= 0.874 TL= Pe 0.0 Pv 0.0 30.9 0.0000 ----------------------- Pf 0.0 Pn 17.1 --------10.0---- Pt 17.1 g 4= .0 K= 0.000 L= Q= --------------- 10.0 --------- 0.0 F= R3L F=13.0 Vel= 0 _ 150 Pe 17.1 Pt 17.01 7 .0 D= 0.874 TL= 23.0 0. 0.0 Pv 0_ 0000 ------------------- Pf 0.0 Pn 17.1 7 ------------------- ------------ t 17.1 9 q= 0.0 K= 0.000 L= Q= _ ______ 16.0 ----_--Pt -17.1 0.0 F= F= Vel= 0.0 17.1 Pt 17.1 26.0 150 g 1.1L D= 1.101 TL= Pe 0.0 Pv 0.0 44,5 0.0000 0. ---------------------------------------17.1 Pf 0,0 Pn ------Pt-----1 ---- - HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.7 - SUBMITTAL. Page 3 ENGINEERS FIREGUARD SPRINKLER SYSTEMS. (714)926830194. ADDRESS 10131 Cabo Drive, Westminster, ,Fine: C:\RESDEN57\GALLOWAY.RES Date: 05-26-2021 JOB : Galloway Resi e C -FACTOR PRESSURE FLOW K -FACTOR LENGTH FTG FRI-LOSS (psi) PIPE BEG Gpm FITTING TYPE TOTAL (Psi/Ft) N0. DIAMETER -------------- ND ------ --------2.0 _ --- pt 18.4 Pt 18.4 --------E---- -------q_--- 0.0 K= 0.000 L= C= 150 Pe 0.0 Pv -0.5 9 Q= 26.0 F= R3L F 16.0 18.0 0.1105 Pf 2.0 Pn 17.9 22 Vel= 8.8 D= 1.101 TL= pt 20.4 TR ----- --------8.0 Pt 20.4 Pt 20.4 ---------------q- 0.0 K= 0.000 L= C= 150 Pe 2.8 Pv -0.5 TR Q 26.0 F= 2RC F= 3.0 0.1105 Pf 1.2 Pn 19.9 23 Vel= 8.8 D= 1.101 TL= 11.0 pt 24.4 R ------ ----- Pt 24.4 Pt 24.4 ---t----------q_- 0.0 K= 0.000 L= 5.0 C= 150 Pe 1.5 Pv -0.6 Q= 26.0 F= LRCSB F- 23.0 0.1360 Pf 3.8 Pn 23.8 24 9.5 D= 1.055 TL= 28 0 pt 29.8 Vel= ---- ---- 29.8 Pt 29.8 Pt ---------------------- -------------------- 5.0 L= K= 0.000 L= C= 150 Pe 2.8 Pv -0.2 BR Q= 31.0 F= RCL F= 9.0 16.0 0.0311 Pf 0:5 Pn 29. 25 Vel= 5.4 D= 1.527 TL= Pt 33.1 UG ----- ------------------------- -------------- Pt 33.1 Pt 33.1 ---UG ---------q=-- 0.0 K= 0.000 L= 60.0 C= 150 Pe 0.0 Pv -0.2 Q= 31.0 F= 4L F= 28.0 0.0249 Pf 2.2 Pn 32. 26 Vel= 5.0 D= 1.598 TL= 88.0 Pt 35. ------------ WM ----------- --- ----- ----------Pt 35.3 Pt 35.3 ---------------q_ ------ 0.0 K= 0.000 L= 20.0 C= 150 Pe 0.0 Pv -0.9 WM Q= 31.0 F= BCSG F= 17.0 0.1884 Pf 7.0 Pn 34_ 27 Vel= 11.4 D= 1.055 TL= 37.0 pt 42.3 SR Meter = 4.0 ______ ----------------------------- <<< SOURCE ------ »> Pt 46.3 Q= 31.0 16 C=>C0uP19 S=>SwgChk G=>GatVly B=>TeeBch R=>TeeRun E=>45-Elb L=>90-Elb HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.7 - SUBMITTAL. ENGINEERS : FIREGUARD SPRINKLER ADDRESS 10131 SYSTEMS, (714) 310-0194. Cabo Drive, Westminster, CA 92683. DATE : 05-26-2021 FILE : JOB : Galloway C:\RES DEN57\GALLOWAY. y Residence RES PSI ln� E 7 6 5( 4C 30 20 10 0 FIRESpnTMIu ,- s`-0 Water Supply ...__- FLOW - Gpm yV 45 50 Static Resid 58 Psi 20 psi Flow 1000 Gpm Water Demand Avl Press : 57.9 psi @ 31 Gpm Req Press : 46.3 Psi @ 31 Gpm Press Cush: 11,6 psi Copyright: Hydrenics Engineering, 2009, 34119 Fremont B1, Suite 609, Fremont, CA. 94555. (800) 845-9819. HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.7 - SUBMITTAL. ENGINEERS FIREGUARD SPRINKLER SYSTEMS. (719) 310-0194. ADDRESS 10131 Cabo Drive, Westminster, CA 92683. LICENSE C16-992002 DESIGNER Fireguard Sprinkler 05-26-2021 Systems, Inc. FILE GALLOWAY JOB NAME Galloway Residence LOCATION 1227 Outrigger Drive DESIGN DATA. DESIGN CRITERION: MIN SPR FLOW : AREA PER SPRINKLER : TOTAL CALCULATED AREA : TOTAL SPRINKLERS CALCULATED FLOW DATA. TOTAL SPRINKLER FLOW ; DOMESTIC DEMAND : TOTAL WATER REQUIRED BASE OF RISER NODE FLOW PRESS NFPA 13D 2016 EDITION REMOTE AREA #2 13 Gpm 256 Sq Ft 512 Sq Ft 2 2 6. 5 Gpm 5.0 Gpm 31.5 Gpm BR 31.5 Gpm 30.0 Psi AUTHORITY HAVING JURISDICTION : NewportBeach Fire Department PHONE : 949-644-3309 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.7 - SUBMITTAL. Page 1 ENGINEERS : FIREGUARD SPRINKLER SYSTEMS. (714)926830194. ADDRESS : 10131 Cabo Drive, Westminster, Date: 05-26-2021dine: C.\RESDEN57\GALLOWAY.RES JOB : Galloway DESIGN I SPRINKLER MANUF SENJU - RC -RES, 16x16, K=4.9, 2=7 MODEL RC -RES p,p psi DENSITY 0.05 Gpm/Sq Ft VALVE 256 Sq Ft DESIGN AREA 512 Sq Ft AREA / SPR METER 4.0 Psi SPRINKLER Q 13.0 GPM PIPES 15 NODES 15 SOURCE STATIC 58 Psi RESIDUAL 20 Psi FLOW 1000 GPM ELEVATION K -FACTOR PRESSURE DISCHARGE NODE Psi GPM NO. Feet ---------------------------------16. 1 14.00 16.6 2 14.00 16.7 3 14.00 16.6 14.00 4.9 13.0 4 14.00 4.90 7. 13.5 5 0 7.66 6 14.00 10.0 7 14.00 15.1 8 14.00 18.4 9 14.00 20.5 14.00 RR 7.50 30.0 5.0 DOME BR 4.00 33.4 UG -2.50 35.7 WM -2.50 46.9 SR -2.50 SOURCE S PP.INKLERS FLOWING 2 256 Sq Ft AREA PER SPRINKLER 512 Sq Ft TOTAL DESIGN AREA MIN SPRINKLER FLOW 13 GPM 0.051 Gpm/Sq Ft REQUIRED DENSITY 0,051 Gpm/Sq Ft COMPUTED DENSITY TOTAL SPRINKLER FLOW 6.5 26.5 GPM GPM TOTAL DOMESTIC FLOW 31.5 GPM TOTAL WATER REQUIRED TOTAL SPRINKLER PRESS 2.9 42.9 Psi Psi WATER METER LOSS 0 0 Psi VALVE FIXED LOSS SUPPLY PRESS AVAILABLE 57.9 9 Psi46 psi DEMAND PRESS REQUIRED 11.0 Psi PRESSURE CUSHION MAXIMUM VELOCITY 11.6 FIS CopyrigW 2009) by Hydronics Engineering 34119 Fremont B1, Suite 609 Fremont, Ca., 94555 (800) 845-9819 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.7 - SUBMITTAL. Page 2 ENGINEERS FIREGUARD SPRINKLER SYSTEMS. (714) 310-0194. ADDRESS 10131 Cabo Drive, Westminster, CA 92683. Date: 05-26-2021 File: C:\RESDEN57\GALLOWAY.RES JOB : Galloway Residence PIPE BEG FLOW K -FACTOR LENGTH C -FACTOR PRESSURE NO. GPM FITTING TYPE FTG FRI-LOSS (Psi) END DIAMETER TOTAL (Psi/Ft) 1 - q= --- 0.0 K= ----- 0.000 --------- L- 4.9 --------- Pt ------------- 16.7 Pt 16.7 1 Q= 0.0 F= B3L F= 15.0 C= 150 Pe 0.0 Pv 0.0 Vel= 0.0 D= 0.874 TL= 19.9 0.0000 Pf 0.0 Pn 16.7 3 Pt 16.7 2 - q- ------ 0.0 K= -------- 0.000 ----------------------------------- L- 4.9 Pt 16.6 Pt 16.6 2 Q= 0.0 F= B31, F= 15.0 C= 150 Pe 0.0 Pv 0.0 Vel= 0.0 D= 0.874 TL= 19.9 0.0000 Pf 0.0 Pn 16.6 4 Pt 16.6 3 - ------------------------------------------------------------- q- 0.0 K= 0.000 L= 12.3 Pt 16.7 Pt 16.7 3 Q= 5.1 F= 2R2L F= 12.0 C= 150 He 0.0 Pv 0.0 Vel= 1.7 D= 1.101 TL= 24.3 0.0055 P£ 0.1 Pn 16.7 4 Pt 16.6 3 - q_ 0.0 --_--------- K= 0.000 ----------------------------------- L- 123.2 Pt 16.7 Pt 16.7 4 Q= 5.1 F= 12R2B32L F= 182.0 C= 150 Pe 0.0 Pv 0.0 Vel= 1_7 D= 1.101 TL= 305.2 0.0055 Pf 1.7 Pn 16.7 9 Pt 18.4 4 ---------------- q= 0.0 K= 0.000 L= 96.1 Pt 16.6 Pt 16.6 5 Q= 5.1 F= llR4B28L F= 171.0 C= 150 Pe 0.0 Pv 0.0 Vel- 1.7 D= 1.101 TL= 267.1 0.0055 Pf 1.5 Pn 16.6 8 Pt 15.1 -------------------------------------------------------------------------- 8 q= 0.0 K= 0.000 L= 19.3 Pt 15.1 Pt 15.1 6 Q= 21.4 F= 3R4L F= 23.0 C= 150 Pe 0.0 Pv -0.3 Vel= 7.2 D= 1.101 TL= 42.3 0.0771 Pf 3.3 Pn 14.8 9 Pt 18.4 -------------------------------------------------------------------------- 5 q= 13.0 K= 4.900 L= 13.9 Pt 7.0 Pt 7.0 7 Q= 13.0 F= R4L F= 17.0 C= 150 Pe 0.0 Pv -0.3 Vel= 7.0 D= 0.874 TL= 30.9 0.0944 Pf 2.9 Pn 6.7 7 Pt 10.0 -------------------------------------------------------------------------- 6 q= 13.5 K= 4.900 L= 10.0 Pt 7.6 Pt 7.6 8 Q= 13.5 F= R3L F= 13.0 C= 150 Pe 0.0 Pv -0.4 Vel= 7.2 D= 0.874 TL= 23.0 0.1016 Pf 2.3 Pn 7.3 7 Pt 10.0 -------------------------------------------------------------------------- 7 q- 0.0 K= 0.000 L= 18.5 Pt 10.0 Pt 10.0 9 Q= 26.5 F= RB4L F= 26.0 C= 150 Pe 0.0 Pv -0.5 Vel- 8.9 D= 1.101 TL= 44.5 0.1148 Pf 5.1 In 9.4 8 -------------------------------------------------------------------------- Pt 15.1 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.7 - SUBMITTAL. Page 3 ENGINEERS FIREGUARD SPRINKLER SYSTEMS. (714) 310-0194. ADDRESS 10131 Cabo Drive, Westminster, CA 92683. Date: 05-26-2021 File: C:\RESDEN57\GALLOWAY.RES JOB : Galloway Residence PIPE BEG FLOW K -FACTOR LENGTH C -FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FRI-LOSS (Psi) END DIAMETER TOTAL (Psi/Ft) ------- - -- 9 - - q- ------- 0.0 ----- K- 0.000 L= 2.0 ---- Pt ----- 18.4 Pt - - 18.4 22 Q= 26.5 F= R3L F= 16.0 C= 150 Pe 0.0 Pv -0.5 Vel- 8.9 D= 1.101 TL= 18.0 0.1148 If 2.1 Pn 17.9 TR Pt 20.5 ------- TR q= ------ 0.0 ----- K= 0.000 L= 8.0 -- Pt ---- 20.5 Pt --- 20.5 23 Q= 26.5 F= 2RC F= 3.0 C= 150 Pe 2.8 Pv -0.5 Vel- 8.9 D= 1.101 TL= 11.0 0.1148 Pf 1.3 Pn 19.9 R Pt 24.6 ------------- R - q- ------- 0.0 ------ K- 0.000 L- 5.0 - Pt ----- 24.6 Pt --- 24.6 24 Q= 26.5 F= LRCSB F= 23.0 C= 150 Pe 1.5 Pv -0.6 Vel- 9.7 D= 1.055 TL= 28.0 0.1413 Pf 4.0 Pn 23.9 BR It 30.0 -------------------------------------------------------------------------- BR q= 5.0 K= 0.000 L= 7.0 Pt 30.0 Pt 30.0 25 0= 31.5 F= RCL F= 9.0 C= 150 Pe 2.8 Pv -0.2 Vel- 5.5 D= 1.527 TL= 16.0 0.0321 Pf 0.5 Pn 29.8 UG It 33.4 -------------------------------------------------------------------------- UG q= 0.0 K= 0.000 L= 60.0 Pt 33.4 Pt 33.4 26 Q= 31.5 F= 4L F= 28.0 C= 150 Pe 0.0 Pv -0.2 Vel- 5.0 D= 1.598 TL= 88.0 0.0257 Pf 2.3 Pn 33.2 WM Pt 35.7 -------------------------------------------------------------------------- WM q= 0.0 K= 0.000 L= 20.0 Pt 35.7 Pt 35.7 27 Q= 31.5 F= BCSG F= 17.0 C= 150 Pe 0.0 Pv -0.9 Vel- 11.6 D= 1.055 TL= 37.0 0.1944 Pf 7.2 Pn 34.8 SR Pt 42.9 -------------------------------------------------------------------------- Meter = 4.0 16 -------------------------------------------------------------------------- -------------------------------------------------------------------------- Q= 31.5 <<< SOURCE >>> Pt 46.9 E=>45-Elb L=>90-Elb B=>TeeBch R=>TeeRun C=>CouP1g S=>SwgChk G=>GatVly HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 5.7 - SUBMITTAL ENGINEERS FIREGUARD SPRINKLER SYSTEMS. (714) 310-0194. ADDRESS 10131 Cabo Drive, Westminster, CA 92683. DATE 05-26-2021 FILE C:\RESDEN57\GALLOWAY.RES JOB Galloway Residence PSI 100 90 80 70 60 50 40 30 20 10 0 FIRE SPRINKLER HYDRAULIC GRAPH 10 15 20 25 30 35 40 45 50 FLOW - GPM e Water Supply Static 58 Psi Resid 20 Psi Flow 1000 GPM 0- Water Demand Avl Press 57.9 Psi @ 32 GPM Req Press 46.9 Psi @ 32 GPM Press Cush: 11..0 Psi Copyright: Hydronics Engineering, 2009. 34119 Fremont B1, Suite 609, Fremont, CA. 94555. (800) 845-9819.