HomeMy WebLinkAboutPV2021-217 - CalcsVSE Project Number: U4089.0077.211 November 4, 2021 Sater Electric 1709 Rimpau Avenue Corona, CA 92881 REFERENCE: Sean Manavi Residence: 411 Irvine Avenue, Newport Beach, CA 92663 Solar Array Installation To Whom It May Concern: 02-0 U �y2oZl — Zi � L111 Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code: California Building Code, 2019 Edition (2018 IBC) Risk Category: II BUILDING DIVISION Design wind speed, Volt: 95 mph (3 -sec gust) per ASCE 7-16 Wind exposure category: C Mar 31 2022 Seismic design category: D Existing Roof Structure BY: Y.T. Roof slope: 18.4° Home: metal seam over 2x10 rafters @ 24" O.C. Detached Garage: composition shingles over 2x4 Manufactured trusses @ 24"O.C. Connection to Roof Mounting connection metal roof: (1) SnapNRack Wide Base Seam Clamp w/ L Foot & Lock at max. 24" o.c. along rails Zone 1, 2e (Beyond 4' from roof edge or within 4' of roof edge perpendicular to slope): 24" o.c. Zone 2n, 2r, 3e (Within 4' of roof edge parallel w/ slope, 4' of roof ridge, or 4' of cave-eave comer): 24" o.c. Zone 3r (Within 4' of ridge-eave comer): 24" o.c. (2) rails per row of panels, evenly spaced; panel length perpendicular to the rails not to exceed 73 in. Rail cantilever shall not exceed 50% of connection spacing. Mounting connection shingle roof: (1) 5/16" lag screw w/ min. 3" threaded embedment into framing at max. 48" o.c. (portrait and landscape) along rails Zone 1 (Beyond 4' from roof edge): 48" o.c. (portrait and landscape) Zone 2r (Within 4' of roof ridge): 48" o.c. (portrait and landscape) Zone 2e, 3 (Within 4' of roof edge perpendicular to slope or within 4' of roof comer): 48" o.c. (portrait and landscape) (2) rails per row of panels, evenly spaced; panel length perpendicular to the rails not to exceed 73 in. Rail cantilever shall not exceed 50% of connection spacing. 651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 /T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com Conclusions VSE Project Number: U4089.0077.21I Sean Manavi Residence 11/4/2021 Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. In the area of the solar array, other live loads will not be present or will be greatly reduced (2019 CBC, Section 1607.13.5). The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 503.3 of the 2019 CEBC are met and the structure is permitted to remain unaltered. The solar array will be flush -mounted (no more than 10" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case. Regarding seismic loads, we conclude that any additional forces will be small. Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 6.7%. Because the increase in lateral forces is less than 10%, this addition meets the requirements of the exception in Section 503.4 of the 2019 CEBC. Thus the existing lateral force resisting system is permitted to remain unaltered. Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry -wide methods and applicable safety standards. The contractor must notify Vector Structural Engineering, LLC should any damage, deterioration or discrepancies between the as -built condition of the structure and the condition described in this letter be found. Particular attention must be paid to the maximum allowable spacing of connections and the location of solar panels relative to roof edges. Connections to existing roof framing must be staggered, except at array ends, so as not to overload any existing structural member. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables. The design of the solar panel racking (mounts, rails, etc.) and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. VECTOR STRUCTURAL ENGINEERING, LLC Jacob Proctor, P.E. CA License: 70567 - Expires: 06/30/2023 Project Engineer Enclosures JSP/ryl 11/04/2021 651W. Galena Park Blvd., Ste. 101 /Draper, UT 84020 /T (801) 990-1775 / F (801) 990-1776 /www.vectorse_com. JOB NO.: U4089.0077.211 EOTORSUBJECT: SEISMIC LOADS E n O I n E E R S PROJECT: Sean Manavi Residence Home CHECK INCREASE IN OVERALL SEISMIC LOADS Estimated Roof Dead LoadA.% psf Solar Dead Loadpsf % Roof Covered 24% Equiv. Total Dead Load "` psf Addt'I Seismic Weight 6.7% Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 6.7%. Because the increase is less than 10%, this addition meets the requirements of the exception in Section 503.4 of the 2019 CEBC. Thus the existing structure is permitted to remain unaltered. �RCTOR E n 9 1 n E E R S PROJECT: Sean Manavi Residence JOB NO.: U4089.0077.211 SUBJECT: WIND PRESSURE Home ADDITIONAL INPUT & CALCULATIONS: Height of Roof, h [ft]: Comp/Cladding Location: Enclosure Classification: Zone 1, 2e GCp: Zone 2n, 2r, 3e GCp: Zone 3r GCp: 1 Il u, V -w _.. (negative coeff.) a: 9.5 Table 26.11-1 zg [ft]: 900 Table 26.11-1 Kh: 0.85 Table 26.10-1 Ke: 1.00 Table 26.9-1 Kn: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 16.6 Equation 26.10-1 YE: � s -FW Section 29.4.4 WIND PRESSURES: Equation 29.4-7 P — q (GCp)(YE)(Y.) Zone 1, 2e, p [psf]: Zone 2n, 2r, 3e, p [psf]: Zone 3r, p [psf]: 39.9 psf (1.0 W) 59.8 psf (1.0 W) 71.8 psf (1.0 W) (a= 3 ft) z, A JOB NO.: U4089.0077.211 E CTO R SUBJECT: CONNECTION E n p I n E E R S Home PROJECT: Sean Manavi Residence Calculate U lift Forces on Connection Max Trib. Max Uplift Pressure Max Trib. Width' Areae Force (0.6 Dead -0.6 Wind) (ft) (ftz) (Ibs) (psf)---77=— NO _ - r� ' a MMMEM- EMM Calculate Connection Capacity Roof Connector: Additional Connection Info: Ultimate Capacity3 [lbs/in]: Factor of Safety: Qty. of Connectors: Prying Coefficient: Total Capacity [lbs]: ine Result Maximum Demand: Connection Capacity:EMEE] Res ult: Capacit Demand Connection is adequate. Notes 1.'Max Trib. Width' is the width along the rails tributary to the connection. 2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 73". 3. Ultimate capacity values are from manufacturer testing. Roof deck model is unknown or has not been tested for this connector. The capacity used is based on conservative values from testing of the connector on similar roof deck model. 4. Install metal roof connector per manufacturer's written instructions with recommended fasteners when indicated. U4189, �!ECTOR JOB NO,: GRAVITY SUBJECT: GRAVITY LOADS E n e i n E E R s PROJECT: Sean Manavi Residence Home GRAVITY LOADS Roof Pitch 1*M 4 ;x:12 ROOF DEAD LOAD (D) Design material weight [psf] Increase due to pitch Material weight [psq Metal Seam 2.6 1.05 2.5 1/2" Plywood 1.1 1.05 1.0 Framing 3.0 3.0 Insulation 0.0 0.0 1/2" Gypsum Clg. 0.0 1.05 0.0 M, E & Misc 0.0 0.0 Total Existing Roof DL 6.7 PV Array DL 3.2 1.05 3 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf) ASCE 7-16 Table 4.3-1 Roof Live Load With PV Array [psf) 2019 CBC, Section 1607.13.5 SECTOR E In G I n E E R s PROJet:T ,.___ KA -..,A Residence JOB NO.: U4089.0077.211 SUBJECT: LOAD COMPARISON Home Summary Existing With PV Array 7 10 D [pst] 0 Lr [psfl 20 S [psfl 0 0 Maximum Gravity Loads: Existing With PV Array 21 11 ASCE 7-16, Section 2.4.1 (D + Lr) / Cd [psfl 11 ASCE 7-16, Section 2.4.1 (D + S) / Cd [psfl 7 (Cd = Load Duration Factor = 0.9 for D, 1.15 for S, and 1.25 for Lr) Maximum Gravity Load [psf]: 21 11 Ratio Proposed Loading to Current Loading: 51% OK gravity loads, and thus the stresses of the structural elements, in the area of the more than 5%. Therefore, the r array are either decreased or increased by no arements of Section 503.3 of the 2019 CEBC are met and the structure is permitted remain unaltered. �EcT0R E n p 1 n E E R S CHECK SE IN OVERALL SEISMIC LOADS Area Covered JOB NO.: U4089.0077.211 SUBJECT: SEISMIC LOADS Detached Graged a® 46% 12.1 psf Addfl Seismic uveiy- - total weight and ing seismic The installation thelon of the s lar panels tha1 represents theease in eequireme tstof he excteption i section ) 503.4 of the 2 the 2019 CEBC. Thus the existing structure is permitted to remain unaltere . \LECTOR e n o PROJECT: Sean Manavi Residence Calculate U lift Forces on Connection Calculate Connection Capacity Lag Screw Size [in]: Cd: Embedment? [in]: Grade: JOB NO.: U4089.0077.211 SUBJECT: CONNECTION Detached Garage Max Trib. Max Uplift Areae Force (ftz) (Ibs) 12.2 229 12.2 302 Table 2.3.2 Nominal Capacity [Ibs/in]:P " ' Number of Screws: Prying Coefficient: 1.4 Total Capacity [lbs]: 703 Determine Maximum Demand [Ibs]:329 Lag Screw Capacity [lbs]: 703 Result: Capacit > DEemand Connection is adequate. Notes I. 'Max Trib. Width' is the width along the rails tributary to the connection. 2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 73". 3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the embedment length. SECTOR E n O i n E E R S PROJECT: Sean Manavi Residence Label: maPsro#, SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 95 Exposure Category: C Risk Category: II ADDITIONAL INPUT &CALCULATIONS: Height of Roof, h [ft]: Comp/Cladding Location: Enclosure Classification: Zone 1 GCp: Zone 2r GCp: Zone 2e, 3 GCp: Figure 30.3-2E (negative coeff.) JOB NO.: U4089.0077.211 SUBJECT: WIND PRESSURE Detached Garage Note: Calculations per ASCE 7-16 L, S o: 9,5 Table 26.11-1 z9 [ft]: 900 Table 26.11-1 Kh: 0.85 Table 26.10-1 Ke: 1.00 Table 26.9-1 Kn: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 velocity Pressure, qh [Psfl: 16.6 Equation 26.10-1 f s 5 Section 29.4.4 Equation 29.4-7 p = q h (GCP)(YE)(Y a) WIND PRESSURES: Zone 1, P [Psfl: Zone 2r, p [psf]: Zone 2e, 3, p [Psfl: 34.3 psf (1.0 W) 44.4 psf (1.0 W) 48.1 psf (1.0 W) (a= 3 ft) \/ECTOR E PROJECT e--. nnannvi Residence GRAVITY LOADS ROOF DEAD LOAD (D Composite Shingles 112" Plywood Framing Insulation 1/2" Gypsum Clg. M, E & Misc Total Existing Roof DL PV Array DL ROOF Existing Design Roof Live Load [psfl Roof Live Load With PV Array [psfl JOB NO.: U4089.0077.211 SUBJECT: GRAVITY LOADS Detached Roof Pitch: Ii° :12 Design material Increase due to Material weight .. «_.' 21 1.05 2.0 1.1 1.05 1.0 3.00.5 3.0 0.5 21 1.05 2.0 1.5 1.5 10.3 3 32 1.05 ASCE 7.16 Table 4.3-1 2019 CBC, Section 1607.13.5 JOB NO.: U4089.0077.211 E O T O R SUBJECT: LOAD COMPARISON E n C3 I n E E R 8 Detached Garage PROJECT: Sean Manavi Residence Summary Loads Existing With PV Array D [psfl 10 13 Lr [psfl 20 0 S [psfl 0 0 Maximum Gravity Loads: Existing With PV Array (D + Lr) / Cd [psf] 24 15 ASCE 7-16, Section 2.4.1 (D + S) / Cd [psf] 11 15 ASCE 7-16, Section 2.4.1 (Cd = Load Duration Factor = 0.9 for D, 1.15 for S, and 1.25 for Lr) Maximum Gravity Load [pst]: 24 15 Ratio Proposed Loading to Current Loading: 62% OK The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the rPnuirements of Section 503.3 of the 2019 CEBC are met and the structure is permitted remain unaltered.