Loading...
HomeMy WebLinkAboutF2022-0017 - MiscGT)�A, 422,,�' voW MWA O e'�Vd- MacArthur Blvd. Newport Beach, CA 92660 Detection & Controls for Pre -Action Systems IT Rooms - 9th & 10th Floor Product Data Sheets CSFM Listing Sheets D & H Fire Protection, Inc., 433 W. Allen Ave., Ste. 111, San Dimas, CA 91773 (E)POTTER ® The Symbol of Protection Features 60 addresses available on this analog addressable system Additional system capacity achieved via multi -point SLC modules • 99 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built -In System Operates as Class A or Class B for SLC, P -Link and NACS • 5 Amp Power Supply, Expandable to 310 amps • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 • 2lnput/Output (I/O) Circuits for system flexibility rated at 1 Amp each, ideal for manual release and abort • Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes • Dedicated Alarm, Supervisory and Trouble Relays • 4,000 Event History Buffer Cabinet will house up to 18 AH batteries Optional two line DACT with UD -2000 that can report General, Zone or Point Information Built in IP Communicator IPA -60 Fire Alarm Control Panel pySEMBtFo rn� u • Ethernet Port for Programming and Network Connectivity • E -Mail System Status, Reports and Event Information 16'W x 1711 x 3'/8"D AC Mains • Product includes 5 year warranty 2.0 Amps @ 240 VAC 50/60 HZ • UUKL Listed for Smoke Control - APPROVED LISiEU Description The IPA -60 is an analog/addressable releasing fire alarm system with a total system capacity of 60 addresses. Additional capacity on the system is achieved using multi -point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The IPA -60 has a 5 Amp power supply with two Notification Appliance Circuits (NACS) and two Input/Output (1/O) circuits. TheNACs are rated at 3 Amps each and the UOs are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with the exclusive Quadrasyne each output may have a unique brand and all strobes will flash together. The I/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The IPA -60 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN -1000 may be used to extend releasing capability. The NACS may be expanded using the PSN -1000 series intelligent power supplies. Each PSN -1000 adds another 10 Amps of power, 2 additional input circuits and the IPA -60 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN - 1000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. Technical Specifications Dimensions 16'W x 1711 x 3'/8"D AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current -130 mA Alarm Current -200 mA • 5 Amps power for NACS, I/O, and P -Link Battery • 3 Amps per NAC, regulated • 1 Amp per I/O circuit, regulated • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P -Link maximum current of 1 Amp Temperature and 32° to 1200 (0°C to 49°C) with a maximum Humidity Range humidity of 93% non -condensing. NFPA 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 750, and 2001 ANSI/UL 864 - Local (L), Remote Sta- tion (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Standards Automatic (A), Manual (M), Water flow (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded INC), Reverse Polarity (Rev Pol), Other Technologies (OT) IBC 2000, 2003, 2006, 2009, 2012 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE OF (E)POTTER The Symbol of Protection IPA -60 Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 60 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PADI00-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD100-PHD Combination Analog Photo Electric Smoke/Heat Detector— a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135° Fahrenheit heat detector. PAD100-HD Analog Fixed Temperature Heat Detector that is selectable from 135° F to 185°F. PAD100-DUCTR Addressable Duct Smoke Detector with Form C Relay. PAD100-DUCT Addressable Duct Smoke Detector. PAD 100-6B 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD 100-4B 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD 100 -IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PADI00-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PADI00-CD Addressable CO gas detector. PAD100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. PAD100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) PAD100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from I/8W to 4W. Modules Device Description PAD 100 -MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PAD100-PSDA Dual Action Addressable Pull Station. PAD100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PAD100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD 100-ZM Zone Module is used to connect conventional 2 -wire smoke detectors to the system. PAD100-IM Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD100-LED Module provides a single addressable LED that is controlled by the control panel. PAD100-SM Speaker Module provides switching for two audio channels. PADI00-LEDK Addressable LED and key switch that mounts in a single gang box. PAD100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. PAD100-OROI One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 2 OF (E)POTTER IPA -60 The Symbol of Protection Fire Alarm Control Panel SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T -Taps", with a max wiring distance of 10,000 Ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: AC Power - Green • Alarm - Red Earth Fault - Amber Supervisory - Amber Silenced - Amber Trouble - Amber • Pre -Release - Amber • Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P -Link The IPA -60 has a proprietary communication protocol that communicates through a RS -485 connection to field devices. Up to 64 devices may be connected to a single P -Link connection. The P -Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: RA -6075R— 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) — 4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED -16(F) — 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN -1000(E) — 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P -Link repeater. This panel is listed in conjunction with the IPA -60 as releasing circuits. CA -6075 — Class A convertor that converts the SLC, NACs and P -Link connection UD -2000 — UL listed, Dual line telephone alarm communicator DRV -50 — LED driver expander, used to connect up to 50 LEDs in a graphic display FCB -1000 — Fire communication bridge, provides remote mounting of the Ethernet connection FIB -1000 — Fiber interface module, used to extend P -Link to multi - mode fiber (2 required) RLY-5 — Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG -1000 — Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB -1000, FCB -1000 and the SPG -1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC -1000 Multi -Connect allows up to sixty-three IPA series panels to share a single reporting technology. IDC-6—Initiating device circuit provides 6 programmable inputs AE-2—Two card expansion cabinet AE -8 — Eight card expansion cabinet AE -14 — Fourteen card expansion cabinet Ethernet/I.P. Connection The IPA -60 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur -Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101- REV G • 9/19 PAGE 3 OF 4 (E)POTTER IPA -60 The Symbol of Protection Fire Alarm Control Panel Dimensions ® 0 Toa D�IH=3.75" t� DOOR= 16.07" B4O®0X= 15.77" DEFIH=3.84" LEFT SIDE Ordering Information Model Description Stock No. IPA -60 Fire Alarm Releasing Control Panel 3992714 Replacement Board IPA -60 13992738 0 0 RtGHTSIDE owc xsesi Compatible Releasing Devices Note: For releasing applications please order the Potter FOLD (3005012) for circuits connected to a releasing solenoid or actuator. Brand Description Skinner 73218BN4UNLVN0C112CZ 73212BN4TNLVN0C322C2 - Victaulic 753-E Series Mini Max MX123 & MX200 w/ 8876677 & 889323 Viking 11591, 11601, 11602, 13843, & 13844 TLX IPA0036 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 4OF4 (E)POTTFR The Symbol of Protection Features One Class B contact monitoring input Small size allows mounting in most electrical boxes SLC Class A, Class X & Class B 6" Pigtail wiring connections Product includes a 5 year warranty UUKL Listed for Smoke Control Description The PAD100-MIM is used to monitor the status of an initiating device (s) that contain a normally open set of dry contacts. The module is enclosed in a plastic case to protect against inadvertent shorts and ground faults. The case can be mounted using a single screw. The PAD100-MIM has a status indicator LED to indicate communication and alarm condition. In normal condition, the LED flashes when the device is being polled by the control panel. When the input is activated, the LED will flash at a fast rate. Application The micro input module (PAD 100 -MIM) is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. Generally the PAD100-MIM is used to monitor pull stations and other devices where the module is installed in an electrical box or enclosure behind the device being monitored. PAD100-MIM Micro Input Module 1 2 4 a N a2 114 ©POTTER PAD100-MIM (SLC Module) M FM U` APPROVED Technical Specifications Operating Voltage 24.OV Max SLC Standby Current 200µA Max SLC Alarm Current 200µA IDC Input Circuit Wiring Class B Max Wiring Resistance 1004 of IDC Max Wiring 1µF Capacitance of IDC EOL Resistor 5.1K 6d Operating Temperature Range 32 to 120°F (0 to 49eC) Operating Humidity Range 0 to 93% (non -condensing) Max no. of Module Per 127 units Loop Dimensions 1.75" (44.5mm)L x 1.36" (34.5mm)Wx .43" (llmm)D Mounting Options 2-1/2" (64mm) deep single -gang box Shipping Weight 0.3 lbs Potter_ Electric Signal Company, LLC SL Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830079 -REVD • 12/18 PAGE I OF (E)POTTER PAD100-MIM The Symbol of Protection Micro Input Module Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the front of the PAD 100 -MIM. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Wiring Diagram Fig 1 FROM FACP OR PREVIOUS DEVICE AND TO NEXT DEVICE Ordering Information Model Description IStock No. PAD IOO-MIM Micro Input Module 13992700 TO NORMALLY OPEN MONITORED DEVICE 5.1 K OHM REQUIRED Part #3005013 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830079 - REV D • 12/18 PAGE 2 OF 2 (E)POTTER The Symbol of Protection PAD100-DIM Dual Input Module Features A1&6SSmaz• Single module with dual contact monitoring inputs ;e• Two (2) Class B or one (1) Class A monitoring inputsP • SLC Class A, Class X & Class B • Mounts in a standard 4" or double gang box 24.OV • Wiring terminals accessible when mounted in box u • All wiring terminals accept 22 to 12 AWG --� ©PPOTOR • Product includes a 5 year warranty l • UUKL Listed for Smoke Control NOTE: This addressable module does not support 2 -wire smoke �- detectors. 5.1K 4 Description The PAD100-DIM uses one (1) SLC loop address when monitoring two (2) Class B circuits or one (1) Class A circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring two (2) separate class B circuits making it ideal for monitoring sprinkler waterflow and valve tamper switches when they are located in the same proximity. The PAD 100 -DIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When an input is activated, the LED will flash at a fast rate. Application The PAD100-DIM is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD100-DIM is an interface module used to monitor dry contact devices such as sprinkler waterflow, valve tamper switches, or conventional pull stations. The module is capable of monitoring two separate Class B or one Class A circuits. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD100-DIM. When the PAD100- DIM is used to monitor two individual Class B circuits a single device address is assigned, each input is then identified as a sub -point of the module address. For example, if the address number is assigned as "8", the first input will be "8.1" and the second input will be "8.2". Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. FM UL APPROVED Technical Specifications Operating Voltage 24.OV Max SLC Standby Current 240µA Max SLC Alarm Current 240µA Max Wiring Resistance 1004 of IDC Max Wiring Capacitance of IDC 1 pF EOL Resistor 5.1K 4 Raneing Temperature g g 32 to 120°F (0 to 49°C) Ran geerating Humidity 0 to 93% (non -condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (I06mm)W x 1.14"(29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830082 -REVD • 12/18 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Installation Using Compatible Electrical Box Fig 1 Wiring Diagrams PAD100-DIM With One Class Circuit Fig Z FROM FACP OR PREVIOUS MODULE TO NEXT MODULE NOTE: — END -OF -LINE RESISTOR IS NOT REQUIRED PAD100-DLMWith Two Class Circuits Fig 3 FROM FACE OR PREVIOUS MODULE TO NEXT MODULE END -OF -LINE RESISTOR 5.1KOHM�W Partp3005013 END-OPUNE RESISTOR S.IKOHM3SV Part 4300501. Ordering Information CD C MOVE THE "CL -A" DIP SWITCH TO"UP"POSITION FOR CLASS A WIRING P -? CD a C;:Y Nll W C�D Model Description I Stock No. PAD IOO-DIM Dual Input Module 13992703 MOVE THE "CL -A' DIP SWITCH TO"DOWN"POSUION FOR CLASS B WIRING PAD100-DIM Dual Input Module Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830082 -REVD 12/18 PAGE 2 OF 2 I ©POTTER PAD100-NAC ® The Symbol of Protection Notification Appliance Circuit Features • Monitored output module that provides an additional supervised output • Can be used as either a NAC or Releasing Output • NAC can be wired Class A or Class B • Monitors presence of 24 VDC Aux Power • SLC Class A, Class X & Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The PAD100-NAC module uses one (1) address on an SLC Loop. The module provides a programmable source of power to supervise and control one (1) Class B or Class A Notification Appliance or one (1) Class Releasing Circuit. The module requires and supervises a 24 VDC auxiliary power connection. The PAD 100 -NAC includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. Application The PAD100-NAC is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD100-NAC is a monitored Notification Appliance Circuit that wires to the SLC loop to provide an additional notification circuit. When used with a Potter addressable releasing panel, the PAD100-NAC can provide an additional releasing circuit. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switches on the PAD100-NAC module. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. py5EM82Fo r w i � 4 i2 THE JcP e ©Ggo' PR 49% FM X SU& APPROVED Technical Specifications Operating Voltage 24.OV Max SLC Standby Current 200µA j Max SLC Alarm Current 200gA Aux Power Required 16-33 VDC Output Ratings 24 VDC, 2A EOL Resistor 5. IK Q EOL Resistor Diode Stock#3005012 Releasing Applications (Not Included) Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non -condensing) Max no. of Module Per Loop 127 units Dimensions 4.17" (106mm)L * 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830086 -REVD • l2/I8 PAGE 1 OF 2 (E)POTTER ® The Symbol of Protection Installation Using Compatible Electrical Box Fig I Wiring Diagrams Output Connected to a Notification Appliance Circuit Typical Class B Wiring Diagram Fig 2 FROM OFF OR PAEVIOUSMOOULE TONEXLMODULE AUXIUAPYE� VOLTPOWEP EPOMEACP Typical Class Wiring Diagram Fig 3 FT PRO,SR1. FXI1 I Releasing Application Fig 4 FROM FACT OR PREVIOUS MODULE TO NEXT MODULE AUXILIARY da VOLTPOWER FROM FACP O 0 a o PED PAD100-NAC Notification Appliance Circuit END-OFLINE PESSLOR S.IX N. Y.W NOT SUITABLE FOR VNCNPONVATONOF NDIIFlCATON APPLIANCES ..IARNKCIAISA NOTEEND-OLERS' flEOUIBEDSN T T IF. RLE FOB C K'ANIZAUAN OF NOFIF TON APPLIANCES PAOIPP NAC UFI—,n Solenoid NOTE'. END -0F LINE DIODE ASSEMBLY REQUIRED lwlll F0 l NOTE: EOLDENCE SHALLREINSTALLEDIN THESAMEELMICAL ENCLOSUPEASTHE PELEASINLDEVICE. It is possible that the internal relay in the PAD 100 -NAC may be shipped in the non -normal / normal state, connect the module to the SLC loop and reset the control panel before terminatil Ordering Information Model Description I PAD IOO-NAC Notification Appliance Circuit 13992707 Wiring Diagrams Output Connected to a Notification Appliance Circuit Typical Class B Wiring Diagram Fig 2 FROM OFF OR PAEVIOUSMOOULE TONEXLMODULE AUXIUAPYE� VOLTPOWEP EPOMEACP Typical Class Wiring Diagram Fig 3 FT PRO,SR1. FXI1 I Releasing Application Fig 4 FROM FACT OR PREVIOUS MODULE TO NEXT MODULE AUXILIARY da VOLTPOWER FROM FACP O 0 a o PED PAD100-NAC Notification Appliance Circuit END-OFLINE PESSLOR S.IX N. Y.W NOT SUITABLE FOR VNCNPONVATONOF NDIIFlCATON APPLIANCES ..IARNKCIAISA NOTEEND-OLERS' flEOUIBEDSN T T IF. RLE FOB C K'ANIZAUAN OF NOFIF TON APPLIANCES PAOIPP NAC UFI—,n Solenoid NOTE'. END -0F LINE DIODE ASSEMBLY REQUIRED lwlll F0 l NOTE: EOLDENCE SHALLREINSTALLEDIN THESAMEELMICAL ENCLOSUPEASTHE PELEASINLDEVICE. It is possible that the internal relay in the PAD 100 -NAC may be shipped in the non -normal / normal state, connect the module to the SLC loop and reset the control panel before terminatil Ordering Information Model Description I Stock No. PAD IOO-NAC Notification Appliance Circuit 13992707 state. To ensure that the internal relay is set to the ng to the modules output. Potter Electric Signal Company, LLC St. Louis, MID Phone: 800-325-3936 www.pottersignal.com 8830086 -REVD 12/18 PAGE 2 OF 2 (E)POTTER PAD100-4DB/6DB The Symbol of Protection 4 /6 Addressable Detector Base Features • Terminals Marked with Polarity to assist with installation • Duplicate terminals for in and out SLC wiring • Terminals accept 22 to 12 AWG wire sizes • Installs on single gang, double gang, octagon or 4" square box Locking tab prevents unauthorized detector removal • Product includes 5 year warranty Application The Potter PAD100-6DB and PAD100-4DB detector bases are used to install Potter's addressable smoke and heat detectors. The PAD100- 6DB will mount on a single gang, double gang, octagon or 4" square electrical box. Description The PAD100-6DB and PAD1004DB are low -profile, surface mount bases used with Potter's addressable detectors. The base uses screw - clamp terminals that accept wire ranging from 22 to 14 AWG. When installed on recessed electrical boxes the PAD 100-6DB is wide enough to completely cover the back box and the immediate surrounding area. The base is equipped with a locking tab to deter unauthorized removal of the attached detector. PyS����EMyyyygTFO ♦/2 THE VS a FM O APPROVED X LISTED Technical Specifications Mounting Options Single gang, double gang, octagon, and 4" square box _Terminals Screw -Clamp Type Wire Guage 22 to 12 AWG D Dimensions Diameter: 6.3 in (166 mm) Height 0.72 in (18 mm) Shipping Weight I 87g (3.07 oz) Material I Durable Plastic Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com PRINTED IN USA 8830107 - REV C 12/18 PAGE t OF 2 (E)POTTER The Symbol of Protection Locking Feature The PAD100-61)(B and PAD1004DB include a locking feature that prevents removal of the detector without using a tool. 1. To eliminate this feature, break off the locking tab (refer to Figure 1), and then install the detector. Fig. 1 I III i E til I � Break off tab (,m, �- a ea) A anage to disable locking feature. 2. To remove the detector from the base when the locking feature has been enabled, insert a small screw driver into the slot on the base to push the plastic tab while simultaneously turning the detector head counter -clockwise. Fig. 2 Insert small screwd,. me, slot to remove detector from base. PAD100-4DB/6DB 4 %6"Addressable Detector Base Wiring Diagram Fig. 3 To FAi Loop ( Ordering Information Model Description StockNo. PAD 100-6DB 6" Sensor Base 3992732 PAD 100-4DB 4" Sensor Base 3992731 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com PRINTED M USA 8830107 - REV C • 12/18 PAGE 2 OF 2 (P)POTTER The Symbol of Protection PAD100-PD Photoelectric Smoke Sensor Features SEMm<F P O • Low profile, less than 2 inches with the base 0"Oh' \ •p7 • Wide selectable sensitivity range of 1.0 to 3.70/o/foot *44*l Y 2 r"E os • Sensor communicates sensitivity to control panel • UL listed smoke calibration and sensitivity , • Optional locking tab to prevent unwanted removal 4 • Simple DIP switch address setting, no programming tool required LED alarm indicator Product includes a 5 year warranty UUKL Listed for Smoke Control Description The Photoelectric Smoke Sensor is a listed Analog Addressable smoke sensor compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD 100 -PD is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD100-PD has a sensitivity range of 1.0 to 3.7 %per foot and is UL. The PAD100-PD features drift compensation and has built in dirty detector warning as well as. The PADI00-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD100-PD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. FM EISTED APPROVED 4 Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 pA Alarm indicator 1 LED Alarm set -point range 1.0 to 3.7 0/./ft 3.6-12 %/m Installation temperature 32 to 120 ° F / 0 to 49 ° C range Operating relative humidity range 0% to 93% (Non -condensing) Start -uptime Max.I sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop. Color Eggshell White Weight (without base) 101g (3.56oz) Dimensions (without Height: 1.35 in (34mm) base) Diameter: 3.93 in (100 mm) Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830108 - REV D • 12/18 PAGE 1 OF 2 (E)POTTER PAD100-PD The Symbol of Protection Photoelectric Smoke Sensor Air Velocity Ratings The PAD 100 -PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD 100 -PD will operate even though the LED may not illuminate. Operation The PAD100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD100-PD with the PAD 100-41313 or PAD100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD100-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned or replaced. The PAD100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE., As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD100-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4" Standard Base 3992731 PAD100-6DB 6" Standard Base 3992732 PAD 100 -IB 6" base with an isolator module included. 3992730 PAD 100 -RB 6" base with one Form -C relay contact. 2A @ 30VDC, 0.5A @ 125VAC 3992728 PAD100-SB 6" base with sounder module included. Sound pattern is provided from external source. 3992729 PAD100-SPKB 6" base with speaker included 13992762 Ordering Information Model Description I Stock No. PAD 100 -PD Photoelectric Smoke Sensor 13992733 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830108 -REVD • l2/18 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 9 LISTING No. 7165-0328:0500 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Brad Serangeli (314) 595-6900 Fax (314) 595-6999 Email: brads@poffersignal.com DESIGN: Models IPA -60, IPA -100, and IPA -4000 fire alarm control units. Automatic, Manual, waterflow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay -One Input Module PAD 100 -RM Relay Module PAD 100 -SIM Single Input Module PAD 100 TRTI Two Relay -Two Input Module PAD 100-ZM Zone Module PAD 100 -IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100 -SM Speaker Module PAD 100 -MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC -1000 Multi -Connect PAD 100-DUCTR AE -2 Enclosure *SLCE-127 Loop Expander RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances independent verification of any claims. and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally verify correct compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual listee's data sheet, installation instructions for details. 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0328:0502 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIESIMISC. DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Brad Serangeli (314) 595-6900 Fax (314) 595-6999 Email: brads@pottersignal.com DESIGN: Models PAD100-4DB, PAD 100-6DB, PAD100-RB and PAD100-SB detector bases. Refer to Listee's data sheet for detailed product description and operational considerations. RATING: 24 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a addressable isolator base for use with separately listed compatible fire alarm control units and listee's separately listed Models PAD -100 -PD and PAD-100-PHD (CSFM#7272-0328:0504), PAD -100 -HD (CSFM#7270-0328:0503) and PAD -100 -CD (CSFM#5278-0328:0506) detector heads. Refer to listee's Installation Instruction Manual for details. i4 06-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7272-0328:0504 Page 1 oft CATEGORY: 7272 -- SMOKE DETECTOR -SYSTEM TYPE -PHOTOELECTRIC LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States This listing is based upon technical data submitted Contact: Brad Serangeli(314) 595-6900 Fax (314) 595-6999 CSFM Fire Engineering staff Email: brads@poftersignal.com DESIGN: Models PAD100-PD, PAD100-DD and PAD100-PHD photoelectric smoke detector heads. make an independent verification of any claims. This Model PAD100-PHD has an intergral heat detector. Refer to Listee's data sheet for detailed product description and operational considerations. RATING: 24 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances operational requirements or installation criteria. and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Models PAD100-PD and PAD100-PHD are listed as photoelectric smoke detector heads for use with listee's detector base Models PAD100-4DB, PAD100-6DB, PAD100-RB, PAD100-SB (CSFM#7300-0328:502) and Model PAD100-IB (CSFM#7300-0328:501). Model PAD100-DD is listed as a photoelectric smoke detector head for use with Model PAD100-DUCT (CSFM#3248-0328:0505). Refer to listee's Installation Instruction Manual for details. 06-21-2017 dcc Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division =N This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listens data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE '` LISTING No. 7300-0328:0514 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Brad Serangeli (314) 595-6900 Fax (314) 595-6999 Email: brads@pottersignal.com DESIGN: Model PAD100-DIM Dual Input Module Model PAD100-LED Addressable LED Module Model PAD100-OR01 One Relay -One Input Module Model PAD100-RM Relay Module Model PAD100-SIM Single Input Module Model PAD100-TRTI Two Relay -Two Input Module Model PAD100-ZM Zone Module Model PAD100-IM Isolator Module Model PAD100-NAC Notification Appliance Circuit Module Model PAD100-SM Speaker Module Model PAD100-MIM Micro Input Module Model PAD1--- LEDK Key Switch Module Model PAD 100-DRTS Duct Remote Test Switch Model SLCE127 Point SLC Expander Model MC -1000 Multi Connect Model PAD100-DUCTR Model AE -2 Enclosure Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control unit accessories for use with listee's separately listed fire alarm control panels. Refer to listee's Installation Instruction Manual for details. 09-11-18 gt Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division This listing is based upon technical data submitted by the the test results and/or other data but does not make an applicant. CSFM Fire Engineering staff independent verification of any claims. This has reviewed listing is not 'JfE an endorsement or recommendation of the item listed. This listing should not be used to verify correct " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Business License Receipt: Quest https: //apps.newportbeachea.gov/quest/bus_li cense/receipt?receipt=2... 4000 Macu�'nw✓ 61M Logoff (../logoff.aspx) Business License Application - Receipt 3/2/2022 Thank you Gregory! Your Business License Application has been submitted and your payment has been received. Your application will be reviewed by a staff member and then approved accordingly. Please wait 10 business days to receive your Business License Certificate via Postal Service. You may login to Quest at any time to view the status of your request (../main_view). Are you interested in joining your local chamber? Explore the links below to learn more. http://www.newportbeach.com (http://www.newportbeach.com) http://www.cdmchamber.com (http://www.cdmchamber.com) Receipt No: 2024444020 Business License #: BT30078120 Total Amount: $281.00 Please print this receipt for your records: Print Receipt Having technical issues? Send us an email(mai Ito: BLicense@newportbeachca.gov?subject=Quest Issues). PIPS 4 E W P 0 h T B E A C H l i © 2022 - City of Newport Beach 1 of 1 3/2/2022 11:23 AM