HomeMy WebLinkAboutF2021-0170 - CalcsNEWPORT BEACH FIRE DEPT FIRE PREVENTION DIVISION MAY 0 5 2021 Hydraulic Calculations by HydraCALC All-Star Plum & Fire Sprinkler 22672 Lambert St. Suite 619 Lake Forest, Ca 949-470-0072 Job Name Fluter Residence Drawing Residence Location 1808 West Oceanfront Remote Area 1 Contract 1808 Data File Design Area 1.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 All-Star Plum & Fire Sprinkler Fluter Residence HYDRAULIC DESIGN INFORMATION SHEET Name - Fluter Residence Date - 12.15.20 Location - 1808 West Oceanfront ( )4 ( ) S )Other Building - Residence System No. - 1 Contractor - All Star Plumbing & Fire Sprinkler,Inc Contract No. - 1808 Calculated By - All Star Plumbing & Fire Sprinkler,I Drawing No. - 1808 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - LIGHT HAZARD E Domestic Flow Added - +5 Gpm Page 1 Date 12.15.20 S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S )Other Underground 150 W Water Flow Test: T ( )Specific Ruling - Made by Date E Rated Cap. M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make Viking Model VK494 I Elevation at Highest Outlet - Feet Size K -Factor 4.9 G Note: Temperature Rating 200 N Calculation Gpm Required 26.08 Psi Required 44.909 At Test Summary C -Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 72 Elev. R Residual (Psi) - 20 Other Well Flow (Gpm) - 500 Proof Flow Gpm C Flovofinn - P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Revision: 50.53.5 0 N N � N U s N c � n � U U T LL N d q% C CL E a U) as 4 LL N U ONN oJM �mN � � D 3 N -E o 2' 0 c LLD. Co c E m aEi aEi 0m m a N T TO > WU(n mUw CONN Om t0 ,❑❑❑=OLS E m 0 0 a O N m LLJ W O < � Z 0 U J LL N O O O O N � dy3 �N O � y�o �aLL �^a » dU-O-O o O N b )—m �cf)WW �UUU T O O O O N O O U r O V M N r. N m 0 0 0 O N n o N 0 Y1000 N M r � N m � V 000 t0 (0 a000 v in m o 0 0 N O O O m N OOOtt) m m m V N �OOOC� 4n r GOON ti O N 000 N (� m000m O C N N N W ELL m> o _mU�'� L L O N mNNN� N OC U .� n� (D 0i >c E2 aN o > cZ m a (D �W n N U) L U M,0coo C_ O L N CO Nr�n��n au)-0 m rn� o a - m a j Y d p _O X am 75 D L U J U U U7 O n, N (D Y 0 O N c ma N m o C W d E o a E m c C p O > O C � C L0 a N N f6w0 Y 2(n E m m mm $O'O 0 m� O O S m c c D N m � d O lU O y c ,� N L -O LL N MW ry �O O N O L >++ O) w N C O U otj C ' �y m HU L. N fN. .m.. N O)l0 M —w N E -O aE d»>d E CN C -E ON aE¢y N N 7 N d N C N z W MMMLL Z 0 0 0 Z D :DC« N n >,r c x N U)Nt.� y W w ELL - in cd w E m3 m o ui-N a,U �� n, LL QLL lLQ W Z0 w D LL OJd Z W O 0 N o Pressure / Flow Summary - STANDARD All-Star Plum & Fire Sprinkler Page 4 Fluter Residence Date 12.15.20 Node No. Elevation K -Fact Pt Actual Pn Flow Density Actual Area Press Req. SRP1 27.5 4.9 7.04 na 13.0 0.05 256 7.039 EQ=1 28.0 7.05 na H1 28.0 K=K@EQ=1 7.14 na 13.08 1 28.0 7.66 na 2 28.0 10.0 na 3 19.5 15.17 na 4 19.5 16.47 na 5 19.5 18.19 na H3 19.5 21.46 na 6 19.5 24.22 na 7 10.0 30.16 na 8 10.0 30.76 na H2 28.0 K = K @ EQ=1 7.05 na 13.0 TOR 10.0 39.07 na BOR 2.0 44.91 na 5.0 UG1 -3.0 47.5 na METE -3.0 52.52 na TEST -3.0 59.32 na The maximum velocity is 12.82 and it occurs in the pipe between nodes METE and TEST Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen -Williams All-Star Plum & Fire Sprinkler Fluter Residence Page 5 Date 12.15.20 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to 7.0 or Ftngs Pe ****** Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 27.500 4.90 13.00 1 N 7.0 0.500 150 7.039 to 0.0 7.000 -0.217 EQ=1 28 13.0 1.101 0.0 7.500 0.0307 0.230 Vel = 4.38 0.0 EQ=1 13.00 7.052 KFactor= 4.90 H1 28 4.9 13.08 1 N 7.0 4.833 150 7.136 K = K @ EQ=1 to 0 5.0 12.000 0.0 1 28 13.08 1.101 0.0 16.833 0.0310 0.522 Vel = 4.41 1 28 13.00 1 2R 2.0 12.083 150 7.658 to N 7.0 9.000 0.0 2 28 26.08 1.101 0.0 21.083 0.1112 2.344 Vel = 8.79 2 28 0.0 1 0 5.0 8.417 150 10.002 to 0.0 5.000 3.681 3 19.500 26.08 1.101 0.0 13.417 0.1112 1.492 Vel = 8.79 3 19.500 0.0 1 0 5.0 6.667 150 15.175 to 0.0 5.000 0.0 4 19.500 26.08 1.101 0.0 11.667 0.1112 1.297 Vel = 8.79 4 19.500 0.0 1 N 7.0 8.500 150 16.472 to 0.0 7.000 0.0 5 19.500 26.08 1.101 0.0 15.500 0.1111 1.722 Vel = 8.79 5 19.500 0.0 1 3R 3.0 19.333 150 18.194 to N 7.0 10.000 0.0 H3 19.500 26.08 1.101 0.0 29.333 0.1112 3.261 Vel = 8.79 H3 19.500 0.0 1 2N 14.0 9.833 150 21.455 to R 1.0 15.000 0.0 6 19.500 26.08 1.101 0.0 24.833 0.1112 2.761 Vel = 8.79 6 19.500 0.0 1 N 7.0 9.417 150 24.216 to 0.0 7.000 4.114 7 10 26.08 1.101 0.0 16.417 0.1112 1.825 Vel = 8.79 7 10 0.0 1 0 5.0 0.417 150 30.155 to 0.0 5.000 0.0 8 10 26.08 1.101 0.0 5.417 0.1111 0.602 Vel = 8.79 8 10 0.0 1 8R 8.0 52.750 150 30.757 to 2N 14.0 22.000 0.0 TOR 10 26.08 1.101 0.0 74.750 0.1112 8.310 Vel = 8.79 0.0 TOR 26.08 39.067 K Factor= 4.17 H2 28 4.9 13.00 1 N 7.0 7.750 150 7.052 K = K @ EQ=1 to 0 5.0 12.000 0.0 1 28 13.0 1.101 0.0 19.750 0.0307 0.606 Vel = 4.38 0.0 1 13.00 7.658 K Factor= 4.70 TOR 10 26.08 1 S 9.563 8.000 150 39.067 to E 3.825 13.387 3.465 BOR 2 26.08 1.101 0.0 21.387 0.1111 2.377 Vel = 8.79 BOR 2 + 5.00 5.00 1.5 2E 8.704 4.000 150 44.909 to 0.0 8.705 2.166 UG1 -3 31.08 1.505 0.0 12.705 0.0335 0.426 Vel = 5.61 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen -Williams All-Star Plum & Fire Sprinkler Page 6 Fluter Residence Date 12.15.20 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf LIG1 -3 0.0 1.5 3E 18.133 24.250 150 47.501 to 0.0 18.133 4.000 Fixed Loss = 4 METE -3 31.08 1.61 0.0 42.383 0.0242 1.024 Vel = 4.90 METE -3 0.0 1 0.0 27.000 150 52.525 to 0.0 0.0 0.0 TEST -3 31.08 0.995 0.0 27.000 0.2517 6.797 Vel = 12.82 0.0 1.08 59.322 K Factor= 4.04 Computer Programs by Hydratec Inc. Revision: 50.53.5 Hydraulic Calculations by HydraCALC All-Star Plum & Fire Sprinkler 22672 Lambert St. Suite 619 Lake Forest, Ca 949-470-0072 Job Name Fluter Residence Drawing Residence Location 1808 West Oceanfront Remote Area 2 Contract 1808 Data File Design Area 2.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen -Williams All-Star Plum & Fire Sprinkler Fluter Residence Page 5 Date 12.15.20 Nobel Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 19 4.90 20.02 1 O 5.0 0.500 150 16.700 to 0.0 5.000 -0.217 EQ=1 19.500 20.02 1.101 0.0 5.500 0.0682 0.375 Vel = 6.75 Computer Programs by Hydratec Inc. Revision: 50.53.5 0.0 EQ=1 20.02 16.858 KFactor= 4.88 H3 19.500 4.88 20.02 1 2N 14.0 9.833 150 16.858 K = K @ EQ=1 to R 1.0 15.000 0.0 6 19.500 20.02 1.101 0.0 24.833 0.0682 1.694 Vel = 6.75 6 19.500 0.0 1 N 7.0 9.417 150 18.552 to 0.0 7.000 4.114 7 10 20.02 1.101 0.0 16.417 0.0682 1.120 Vel = 6.75 7 10 0.0 1 O 5.0 0.417 150 23.786 to 0.0 5.000 0.0 8 10 20.02 1.101 0.0 5.417 0.0681 0.369 Vel = 6.75 8 10 0.0 1 8R 8.0 52.750 150 24.155 to 2N 14.0 22.000 0.0 TOR 10 20.02 1.101 0.0 74.750 0.0682 5.098 Vel = 6.75 0.0 TOR 20.02 29.253 KFactor= 3.70 TOR 10 20.02 1 S 9.563 8.000 150 29.253 to E 3.825 13.387 3.465 BOR 2 20.02 1.101 0.0 21.387 0.0682 1.458 Vel = 6.75 BOR 2 + 5.00 5.00 1.5 2E 8.704 4.000 150 34.176 to 0.0 8.705 2.166 UG1 -3 25.02 1.505 0.0 12.705 0.0224 0.285 Vel = 4.51 UG1 -3 0.0 1.5 3E 18.133 24.250 150 36.627 to 0.0 18.133 4.000 * * Fixed Loss = 4 METE -3 25.02 1.61 0.0 42.383 0.0162 0.686 Vel = 3.94 METE -3 0.0 1 0.0 27.000 150 41.313 to 0.0 0.0 0.0 TEST -3 25.02 0.995 0.0 27.000 0.1686 4.553 Vel = 10.32 0.0 TEST 25.02 45.866 KFactor= 3.69 Computer Programs by Hydratec Inc. Revision: 50.53.5 P-I,Uu-i5II Hydraulic Calculations by HydraCALC All-Star Plum & Fire Sprinkler 22672 Lambert St. Suite 619 Lake Forest, Ca 949-470-0072 Job Name Fluter Residence Drawing Residence Location 1808 West Oceanfront Remote Area 3 Contract 1808 Data File Design Area 3.WXF 2�ZOI, oy. Computer Programs by Hydratec Inc. Revision: 50.53.5 I All-Star Plum & Fire Sprinkler Page 1 Fluter Residence Date 8.18.21 HYDRAULIC DESIGN INFORMATION SHEET Name - Fluter Residence 13 Residential ( )1 (X)2 Made by Date - 8.18.21 Location - 1808 West Oceanfront Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry Building - Residence ( ) Deluge ( ) PreAction System No. - 3 Contractor - All Star Plumbing & Fire Sprinkler,Inc Contract No. - 1808 Calculated By - All Star Plumbing & Fire Sprinkler,I Drawing No. - 1808 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - LIGHT HAZARD Underground 150 S Type of Calculation: ( )NFPA Y Number of Sprinklers Flowing: S ( )Other T ( )Specific Ruling E 13 Residential ( )1 (X)2 Made by ( )NFPA 13R (X)NFPA 13D ( )4 ( ) Date M Listed Flow at Start Point - 13 GPM System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 GPM Sprinkler or Nozzle S Additional Flow Added - GPM Make Viking Model VK494 I Elevation at Highest Outlet - Feet Size K -Factor 4.9 G Note: Temperature Rating 200 N Calculation GPM Required 26.01 Psi Required 40.399 At Test Summary C -Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 72 Elev. R Residual (Psi) - 20 Other Well Flow (GPM) - 500 Proof Flow GPM S Elevation - P Location: P L Source of Information Y Computer Programs by Hydratec Inc. Revision: 50.53.5 N � O t ao U � Y a C Z n T LL N a C CL E (D 7 J N � d d >ca N Q LL N U r non on M � M m -o J C y 3 E y^ o m C L CLLICo E E E E.� m a a o m > N N ❑ N v w (n (n NU') T CONN OM p E 0 0 0 v O N M LL� W O< Oz M _ 0 J U- N N O O O N M � � J Jho O N N d N__ Ta`NN J J O N5 O 'n m�NN �UUU a � w cn cn ❑ � w F Q N m 0 0 0 N o 0 N N m 0 0 0 M � m I a0oo rn °3 m m ao m o Q000 Q m Hoorn N r m N O O O m O N m N000LL) m m m - 0 0 0 Q m Q N -OOOm 1[l N r OOON Q O N - O O O N &\i m000m O C h N N m .- N E m J ELL m °> o m U w �'� N NN L L J J m C O O 0(D OQ y M U Q C N m a O > n Nwz O m V C Z > m a m d nmo-wmn Qmm�rn � cLi mUino CO L m U rnCO 0��� C O L m m U .•• m m m m U U) g� (D o(DsE3m CO 2 j Y n- L w Nr(7�0 V! m -o U -O N m�U, c nm Ew m L NJ n m' V moo �ti��d �-o o�N E E ca mo c p a > cr 0 cv 0 N N~ N Of m NW O "OOH 2 E Y ` N -moo v u ai = N .O E U) 0-o�m.L.. J m to S m COo= n3 c c a) LL 0 mwd�cn 0 dr �>= N . C mI-C) Z' ..m. .m. N M N -w rn E'mm -o E a»>a Ec me m� m Ta � J W oz oz waaaw � c m� c... U� c 0 am zUUUz ���o �x mg c o> C �� o � N i�mmEm >O _ +-' LL - U)E m3 m ui -N n�U - JC O J r LL¢ wzo�v 0�c0- zw`o 0 m Pressure / Flow Summary - STANDARD All-Star Plum & Fire Sprinkler Fluter Residence Page 4 Date 8.18.21 Node No. Elevation K -Fact Pt Actual Pn Flow Density Actual Area Press Req. SRP1 19.0 4.9 7.04 na 13.0 0.05 256 7.039 EQ=1 19.5 7.05 na H4 19.5 K= K @ EQ=1 7.05 na 13.0 101 19.5 7.75 na 102 19.5 8.62 na 103 10.0 14.55 na 104 10.0 19.67 na 105 10.0 23.97 na 8 10.0 26.3 na H5 19.5 K= K @ EQ=1 7.06 na 13.01 TOR 10.0 34.57 na BOR 2.0 40.4 na 5.0 UG1 -3.0 42.99 na METE -3.0 48.01 na TEST -3.0 54.78 na The maximum velocity is 12.8 and it occurs in the pipe between nodes METE and TEST Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen -Williams All-Star Plum & Fire Sprinkler Page 5 Fluter Residence Date 8.18.21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ****** Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 19 4.90 13.00 1 N 7.0 0.500 150 7.039 7.753 to to to 0.0 7.000 5.0 -0.217 7.000 EQ=1 19.500 13.0 1.101 0.0 7.500 0.0307 0.230 Vel = 4.38 0.0 7.833 0.0 0.866 Vel = 8.77 102 19.500 0.0 EQ=1 N 13.00 9.417 150 8.619 13.01 7.052 KFactor= 4.90 H4 19.500 4.9 13.00 1 N 7.0 10.833 150 7.052 K = K @ EQ=1 to 103 10 0 5.0 12.000 0.0 0.0 0.1106 101 19.500 13.0 1.101 0.0 22.833 0.0307 0.701 Vel = 4.38 101 19.500 13.01 1 N 7.0 0.833 150 7.753 K = K @ EQ=1 to to O 5.0 0.0 7.000 0.0 0.0 101 19.500 102 19.500 26.01 1.101 22.583 0.0 7.833 0.1106 0.866 Vel = 8.77 102 19.500 0.0 1 N 7.0 9.417 150 8.619 13.01 to 7.753 0.0 7.000 10 4.114 1 S 103 10 26.01 1.101 0.0 16.417 0.1106 1.816 Vel = 8.77 103 10 0.0 1 2N 14.0 25.333 150 14.549 0.0 21.387 to 2.365 Vel = 8.77 BOR 2R 2.0 21.000 2E 0.0 4.000 150 104 10 26.01 1.101 O 5.0 46.333 0.1106 5.125 Vel = 8.77 104 10 0.0 1 3N 21.0 12.833 150 19.674 0.424 Vel = 5.59 to -3 0.0 1.5 O 5.0 26.000 150 0.0 to 105 10 26.01 1.101 0.0 0.0 38.833 0.1106 4.295 Vel = 8.77 105 10 0.0 1 R 1.0 15.083 150 23.969 to O 5.0 6.000 0.0 8 10 26.01 1.101 0.0 21.083 0.1106 2.332 Vel = 8.77 8 10 0.0 1 8R 8.0 52.750 150 26.301 to 2N 14.0 22.000 0.0 TOR 10 26.01 1.101 0.0 74.750 0.1106 8.268 Vel = 8.77 0.0 TOR 26.01 34.569 K Factor= 4.42 H5 19.500 4.9 13.01 1 N 7.0 10.583 150 7.059 K = K @ EQ=1 to O 5.0 12.000 0.0 101 19.500 13.01 1.101 0.0 22.583 0.0307 0.694 Vel = 4.38 0.0 101 13.01 7.753 K Factor= 4.67 TOR 10 26.01 1 S 9.563 8.000 150 34.569 to E 3.825 13.387 3.465 BOR 2 26.01 1.101 0.0 21.387 0.1106 2.365 Vel = 8.77 BOR 2 + 5.00 5.00 1.5 2E 8.704 4.000 150 40.399 to 0.0 8.705 2.166 UG1 -3 31.01 1.505 0.0 12.705 0.0334 0.424 Vel = 5.59 UG1 -3 0.0 1.5 3E 18.133 24.250 150 42.989 to 0.0 18.133 4.000 * Fixed Loss = 4 METE -3 31.01 1.61 0.0 42.383 0.0241 1.020 Vel = 4.89 METE -3 0.0 1 0.0 27.000 150 48.009 to 0.0 0.0 0.0 TEST -3 31.01 0.995 0.0 27.000 0.2507 6.769 Vel = 12.80 0.0 TEST 31.01 54.778 KFactor= 4.19 Computer Programs by Hydratec Inc. Revision: 50.53.5 OEM Hydraulic Calculations by HydraCALC All-Star Plum & Fire Sprinkler 22672 Lambert St. Suite 619 Lake Forest, Ca 949-470-0072 Job Name Fluter Residence Drawing Residence Location 1808 West Oceanfront Remote Area 1 Contract 1808 Data File Design Area 1.WXF AUG 2 4 2021 Computer Programs by Hydratec Inc. Revision: 50.53.5 All-Star Plum & Fire Sprinkler Page 1 Fluter Residence Date 8.18.21 HYDRAULIC DESIGN INFORMATION SHEET Name - Fluter Residence Date - 8.18.21 Location - 1808 West Oceanfront Building - Residence System No. - 1 Contractor - All Star Plumbing & Fire Sprinkler,Inc Contract No. - 1808 Calculated By - All Star Plumbing & Fire Sprinkler,I Drawing No. - 1808 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - LIGHT HAZARD S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make Viking Model VK494 I Elevation at Highest Outlet - Feet Size K -Factor 4.9 G Note: Temperature Rating 200 N Calculation Gpm Required 26.08 Psi Required 44.909 At Test Summary C -Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi - Elev. E Static (Psi) - 72 Elev. R Residual (Psi) - 20 Other Well Flow (Gpm) - 500 Proof Flow Gpm S Elevation - P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Revision: 50.53.5 U � c n T Q °� C CL E(D o J .N � a m Q LL N U cc C-4 oJM � c 3 N -E o 2' o CLia Co BEEEEE, uo M2202M a -� TT� W U (nU ,N a�NN OM N �00�=Ocn E m c 0 0 v N M O < � Z 0 O J W O O N O M O O N V N O O � � �N3 � N O `Li on o N i i i 0r -NN �UUU T o 0 0 0 0 0 N (0000 � O O m N 10000 M W O O m m a O O o Olw W 0 d 0 m o a000 v m moon N N000(Op N O O O m m �0 V N d O N O O O N lh m000� C M N M � O N J d O Q O L U Q m aoQLLo- a;D d' 4 U N O M (n "O J V w ) O U U C O L 0 0 mmm� r `• C N '� N (n g� E °EsE3m m« N r m o 19� M amEa (DM j .a U)nmL" L 0 M'V Y moo C LLmN E N > a c o 0 o u— om rn m N M M C � � N E � m mxm= ` M o m? `m Cl) m �'(n N C LL N W y 0 O L j> m mc) -E _ c:n EQ`o N E N ¢UUU¢ E C M C O O M N J N d N C p�Z LL d d d LL ZUUUZ j � C M� .0 d �w 0 n c 0 m xa N U LL�odELL O N N O Qw D_ LL QLL iiQ WZOd'(n ❑JILd Z W O !J/1 N Pressure / Flow Summary - STANDARD All-Star Plum & Fire Sprinkler Fluter Residence Page 4 Date 8.18.21 Node No. Elevation K -Fact Pt Actual Pn Flow Density Actual Area Press Req. SRP1 27.5 4.9 7.04 na 13.0 0.05 256 7.039 EQ=1 28.0 7.05 na H1 28.0 K = K @ EQ=1 7.14 na 13.08 1 28.0 7.66 na 2 28.0 10.0 na 3 19.5 15.17 na 4 19.5 16.47 na 5 19.5 18.19 na H3 19.5 21.46 na 6 19.5 24.22 na 7 10.0 30.16 na 8 10.0 30.76 na H2 28.0 K=K@EQ=1 7.05 na 13.0 TOR 10.0 39.07 na BOR 2.0 44.91 na 5.0 UG1 -3.0 47.5 na METE -3.0 52.52 na TEST -3.0 59.32 na The maximum velocity is 12.82 and it occurs in the pipe between nodes METE and TEST Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen -Williams All-Star Plum & Fire Sprinkler Fluter Residence Page 5 Date 8.18.21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 27.500 4.90 13.00 1 N 7.0 0.500 150 7.039 to to 2N 14.0 0.0 7.000 0.0 -0.217 TOR 10 EQ=1 28 13.0 1.101 74.750 0.0 7.500 0.0307 0.230 Vel = 4.38 0.0 TOR 26.08 EQ=1 13.00 39.067 KFactor= 4.17 H2 28 7.052 K Factor= 4.90 H1 28 4.9 13.08 1 N 7.0 4.833 150 7.136 K = K @ EQ=1 to 0.0 O 5.0 12.000 1.101 0.0 0.0 19.750 1 28 13.08 1.101 0.0 16.833 0.0310 0.522 Vel = 4.41 1 28 13.00 1 2R 2.0 12.083 150 7.658 7.658 to TOR 10 26.08 N 7.0 9.000 8.000 0.0 39.067 2 28 26.08 1.101 E 0.0 21.083 0.1112 2.344 Vel = 8.79 2 28 0.0 1 O 5.0 8.417 150 10.002 BOR 2 to 1.5 2E 8.704 4.000 0.0 5.000 3.681 3 19.500 26.08 1.101 0.0 13.417 0.1112 1.492 Vel = 8.79 3 19.500 0.0 1 O 5.0 6.667 150 15.175 to 0.0 5.000 0.0 4 19.500 26.08 1.101 0.0 11.667 0.1112 1.297 Vel = 8.79 4 19.500 0.0 1 N 7.0 8.500 150 16.472 to 0.0 7.000 0.0 5 19.500 26.08 1.101 0.0 15.500 0.1111 1.722 Vel = 8.79 5 19.500 0.0 1 3R 3.0 19.333 150 18.194 to N 7.0 10.000 0.0 H3 19.500 26.08 1.101 0.0 29.333 0.1112 3.261 Vel = 8.79 H3 19.500 0.0 1 2N 14.0 9.833 150 21.455 to R 1.0 15.000 0.0 6 19.500 26.08 1.101 0.0 24.833 0.1112 2.761 Vel = 8.79 6 19.500 0.0 1 N 7.0 9.417 150 24.216 to 0.0 7.000 4.114 7 10 26.08 1.101 0.0 16.417 0.1112 1.825 Vel = 8.79 7 10 0.0 1 O 5.0 0.417 150 30.155 to 0.0 5.000 0.0 8 10 26.08 1.101 0.0 5.417 0.1111 0.602 Vel = 8.79 8 10 0.0 1 SR 8.0 52.750 150 30.757 to 2N 14.0 22.000 0.0 TOR 10 26.08 1.101 0.0 74.750 0.1112 8.310 Vel = 8.79 0.0 TOR 26.08 39.067 KFactor= 4.17 H2 28 4.9 13.00 1 N 7.0 7.750 150 7.052 K = K @ EQ=1 to O 5.0 12.000 0.0 1 28 13.0 1.101 0.0 19.750 0.0307 0.606 Vel = 4.38 0.0 1 13.00 7.658 KFactor= 4.70 TOR 10 26.08 1 S 9.563 8.000 150 39.067 to E 3.825 13.387 3.465 BOR 2 26.08 1.101 0.0 21.387 0.1111 2.377 Vel = 8.79 BOR 2 + 5.00 5.00 1.5 2E 8.704 4.000 150 44.909 to 0.0 8.705 2.166 UG1 -3 31.08 1.505 0.0 12.705 0.0335 0.426 Vel = 5.61 Computer Programs by Hydratec Inc. Revision: 50.53.5 9 Final Calculations: Hazen -Williams All-Star Plum & Fire Sprinkler Fluter Residence Page 6 Date 8.18.21 Nodal Elev1 K to Node2 Elev2 Fact Qa Qt Nom Fitting or Act Eqiv Len Pipe Ftngs Total CFact Pt Pe *""**** Notes Pf/Ft Pf 24.250 150 47.501 to UG1 -3 0.0 1.5 3E 18.133 24.250 150 47.501 to 0.0 18.133 4.000 * Fixed Loss = 4 METE -3 31.08 1.61 0.0 42.383 0.0242 1.024 Vel = 4.90 METE -3 0.0 1 0.0 27.000 150 52.525 to 0.0 0.0 0.0 TEST -3 31.08 0.995 0.0 27.000 0.2517 6.797 Vel = 12.82 0.0 TEST 31.08 59.322 K Factor= 4.04 Computer Programs by Hydratec Inc. Revision: 50.53.5 Hydraulic Calculations by HydraCALC All-Star Plum & Fire Sprinkler 22672 Lambert St. Suite 619 Lake Forest, Ca 949-470-0072 Job Name Fluter Residence Drawing Residence Location 1808 West oceanfront Remote Area 2 Contract 1808 Data File Design Area 2.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 All-Star Plum & Fire Sprinkler Page 1 Date 8.18.21 Fluter Residence HYDRAULIC DESIGN INFORMATION SHEET S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (X)1 ( )2 ( )4 ( ) S ( )Other Date T ( )Specific Ruling Made by E M Listed Flow at Start Point - 20 Gpm System Type Listed Pres. at Start Point - 16.7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 20 x 20 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 Gem Sprinkler or Nozzle S Additional Flow Added - Gpm Make Viking Model VK494 I Elevation at Highest Outlet - Feet Size K -Factor 4.9 G Note: Temperature Rating 200 N Calculation Gpm Required 20.02 Summary C -Factor Used: W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 72 R Residual (Psi) - 20 Flow (Gpm) - 500 S Elevation - P Location: P L Source of Information: Y Psi Required 34.176 Overhead 150 Pump Data: Rated Cap. @ Psi Elev. Other At Test Underground 150 Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm Computer Programs by Hydratec Inc. Revision: 50.53.5 Date - 8.18.21 Name - Fluter Residence Location - 1808 West Oceanfront System No. - 2 Building - Contractor Residence - All Star Plumbing & Fire Sprinkler,Inc Contract No. - 1808 Calculated By - All Star Plumbing & Fire Sprinkler,I Drawing No. - 1808 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - LIGHT HAZARD S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (X)1 ( )2 ( )4 ( ) S ( )Other Date T ( )Specific Ruling Made by E M Listed Flow at Start Point - 20 Gpm System Type Listed Pres. at Start Point - 16.7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 20 x 20 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 Gem Sprinkler or Nozzle S Additional Flow Added - Gpm Make Viking Model VK494 I Elevation at Highest Outlet - Feet Size K -Factor 4.9 G Note: Temperature Rating 200 N Calculation Gpm Required 20.02 Summary C -Factor Used: W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 72 R Residual (Psi) - 20 Flow (Gpm) - 500 S Elevation - P Location: P L Source of Information: Y Psi Required 34.176 Overhead 150 Pump Data: Rated Cap. @ Psi Elev. Other At Test Underground 150 Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm Computer Programs by Hydratec Inc. Revision: 50.53.5 r., r O O O Q O� l0� N � N N V C y N C LL D_ C❑ C oEEEE'> w w o> m O LU cn (n U),,:, 0 N Om p am: 0U) E N O O a O m W O< O Z m _ J LL O N W O O O N C W O W � � N N cm3 O `n y N O 0 > > o O N N u, 0 w d lO-NN �UUU w o N 0 - 0 - 0 0 0 O- M U W CO r., N m O O O N O o O] N X000 («1 a0 m m D f0 t6 m LL ❑ m O V O O O V m m000 N r in N000(O O N In m IA C N 1[l N r �OOON O N O) O m m000� c N N d a a L J m Z w O Z N c N O = N a � LL n V O�m.-rn wTn. V N U NO 3 c I O O N r Yl m J N Q nU) L_ N E (p k m rn� a m N w A — a3 0 Nrm�o y m ma a�i�moah C moo ld d d'O �N m m `m c o� > C U O J � L W c L N w N n= c c m 0 (n Q.3 C l0 N N C @ L LL 0 m W W> (n O N O m w m w N C> O U c m F Y CU J c E E O< m w r E Q O aN LLdddLL E mw U/T+%N N a� �Z ZUUUZ �y m�c� �,xad6 J (n LL E w m (n42 j w w 7 J y E N o m m E O N O QQ U LL Q LL l i Q W Z 0 K U) J FL d Z W O N N Pressure / Flow Summary - STANDARD b All-Star Plum & Fire Sprinkler Fluter Residence Page 4 Date 8.18.21 Node No. Elevation K -Fact Pt Actual Pn Flow Density Actual Area Press Req SRP1 19.0 4.9 16.7 na 20.02 0.05 400 16.7 EQ=1 19.5 16.86 na H3 19.5 K= K@ EQ=1 16.86 na 20.02 6 19.5 18.55 na 7 10.0 23.79 na 8 10.0 24.16 na TOR 10.0 29.25 na BOR 2.0 34.18 na 5.0 UG1 -3.0 36.63 na METE -3.0 41.31 na TEST -3.0 45.87 na The maximum velocity is 10.32 and it occurs in the pipe between nodes METE and TEST Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen -Williams All-Star Plum & Fire Sprinkler Fluter Residence Page 5 Date 8.18.21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 19 4.90 20.02 1 O 5.0 0.500 150 16.700 to to 0.0 8.705 0.0 5.000 -0.217 -3 EQ=1 19.500 20.02 1.101 0.0224 0.0 5.500 0.0682 0.375 Vel = 6.75 8 10 0.0 1 8R 8.0 52.750 150 24.155 EQ=1 18.133 20.02 4.000 2N 14.0 22.000 25.02 16.858 K Factor= 4.88 H3 19.500 4.88 20.02 1 2N 14.0 9.833 150 16.858 K = K @ EQ=1 to 41.313 0.0 to R 1.0 15.000 0.0 0.0 6 19.500 20.02 1.101 25.02 0.0 24.833 0.0682 1.694 Vel = 6.75 6 19.500 0.0 1 N 7.0 9.417 150 18.552 to E 0.0 7.000 4.114 7 10 20.02 1.101 0.0 16.417 0.0682 1.120 Vel = 6.75 7 10 0.0 1 O 5.0 0.417 150 23.786 to to 0.0 8.705 0.0 5.000 0.0 -3 8 10 20.02 1.101 0.0224 0.0 5.417 0.0681 0.369 Vel = 6.75 8 10 0.0 1 8R 8.0 52.750 150 24.155 to 18.133 4.000 2N 14.0 22.000 25.02 0.0 0.0 TOR 10 20.02 1.101 METE 0.0 74.750 0.0682 5.098 Vel = 6.75 150 41.313 0.0 to 0.0 0.0 TOR 20.02 -3 25.02 0.995 0.0 27.000 29.253 K Factor= 3.70 TOR 10 20.02 1 S 9.563 8.000 150 29.253 to E 3.825 13.387 3.465 BOR 2 20.02 1.101 0.0 21.387 0.0682 1.458 Vel = 6.75 BOR 2 + 5.00 5.00 1.5 2E 8.704 4.000 150 34.176 to 0.0 8.705 2.166 UG1 -3 25.02 1.505 0.0 12.705 0.0224 0.285 Vel = 4.51 UG1 -3 0.0 1.5 3E 18.133 24.250 150 36.627 to 0.0 18.133 4.000 * * Fixed Loss = 4 METE -3 25.02 1.61 0.0 42.383 0.0162 0.686 Vel = 3.94 METE -3 0.0 1 0.0 27.000 150 41.313 to 0.0 0.0 0.0 TEST -3 25.02 0.995 0.0 27.000 0.1686 4.553 Vel = 10.32 0.0 TEST 25.02 45.866 K Factor= 3.69 Computer Programs by Hydratec Inc. Revision: 50.53.5 Hydraulic Calculations by HydraCALC All-Star Plum & Fire Sprinkler 22672 Lambert St. Suite 619 Lake Forest, Ca 949-470-0072 Job Name Fluter Residence Drawing Residence Location 1808 West Oceanfront Remote Area 4 Contract 1808 Data File Design Area 4.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 All-Star Plum & Fire Sprinkler Fluter Residence HYDRAULIC DESIGN INFORMATION SHEET Name - Fluter Residence Date - 12.15.20 Location - 1808 West Oceanfront System Type Listed Pres. at Start Point Building - Residence System No. - 4 Contractor - All Star Plumbing & Fire Sprinkler,Inc Contract No. - 1808 Calculated By - All Star Plumbing & Fire Sprinkler,I Drawing No. - 1808 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - LIGHT HAZARD S Elevation - Page 1 Date 12.15.20 S Type of Calculation: ( )NFPA Y Number of Sprinklers Flowing: S )Other T ( )Specific Ruling E 13 Residential ( )1 ( )2 Made by ( )NFPA 13R (X)NFPA 13D ( )4 ( )X Date M Listed Flow at Start Point - 8 Gpm System Type Listed Pres. at Start Point - 7.12 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 12 x 12 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make Viking Model VK496 I Elevation at Highest Outlet - Feet Size K -Factor 3.0 G Note: Temperature Rating 200 N S Elevation - Calculation Gpm Required 25 Psi Required 25.935 At Test Summary C -Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 72 Elev. R Residual (Psi) - 20 Other Well Flow (Gpm) - 500 Proof Flow Gpm S Elevation - P L Source of Information: Y Computer Programs by Hydratec Inc. Revision: 50.53.5 N � N U M O N O t0O0 O� LO M M M N m o � c 3 N --E o M� (U cLLd CO E E E E rn Ei '0NN OM {p 'OOO2O(n E N O 0 a O O M O O < O Z M _ J LL O M N W O O O N vcoO (D ALL) N N O N O `LL on n » n U a o p N o COCO —M to(D coof0 d� o J+ O O O O O O a cf w w w D Df w M, N (0000 O N N m 0 0 0 N m �(J O)w N 0 a❑ � o c000 v u� M o 0 0 N O O O m O N m N O O O m m m m e-0OO< m V N �000m V O N O O O N m O c m m000- N o d � d J E LL O m C) N N O O Q (D M U Q > C N N a O d O � Z � � c V m m- m T V N U N O 0 U) C U L O C � m_L (n `J N* lu o E 3 m E :5 CO a N j Nrro�O 0 �� N U N r MSO CLLIL c E (p 0 6 w C p 'O nw N h~ N O) f0 O N C 0— (D � N wO J N i4 m 1 N mw m>U) 0 pjf C � m N N J�� m Q O f/7 U1 N '�N Q U U U QC NC N Q C...NTr� J9 N laidddLL �... X N d m Z Z U U U Z j .`N--' N N - U) o�d Em3m ui-N amo J6w I I� ««« 'E N O O N p L.L Q W IL Q W Z O L w 7) ❑ J W d Z W O r0/! N� Pressure / Flow Summary - STANDARD All-Star Plum & Fire Sprinkler Page 4 Fluter Residence Date 12.15.20 Node Elevation K -Fact Pt Pn Flaw Density Area Press No. Actual Actual Rea. SRP1 9.5 3 7.12 na 8.0 0.05 144 7.12 EQ=1 10.0 7.0 na H6 10.0 K=K@EQ=1 7.0 na 8.0 201 10.0 7.28 na 202 10.0 7.71 na 203 10.0 8.72 na 105 10.0 9.6 na 106 10.0 10.32 na 8 10.0 12.58 na H7 10.0 K=K@EQ=1 7.21 na 8.13 H8 10.0 K=K@EQ=1 8.59 na 8.87 TOR 10.0 20.27 na BOR 2.0 25.93 na 5.0 UG1 -3.0 28.5 na METE -3.0 33.46 na TEST -3.0 39.83 na The maximum velocity is 12.38 and it occurs in the pipe between nodes METE and TEST Computer Programs by Hydratec Inc. Revision: 50.53.5 Fhal Calculations : Hazen -Williams All-Star Plum & Fire Sprinkler Fluter Residence Page 5 Date 12.15.20 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe "****** Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 9.500 3.00 8.01 1 N 7.0 0.500 150 7.120 0.0 5.000 0.0 to 201 10 8.13 1.101 0.0 5.500 0.0129 0.071 Vel = 2.74 0.0 7.000 8.720 -0.217 201 8.13 EQ=1 10 8.01 1.101 8.000 0.0 7.500 0.0125 0.094 Vel = 2.70 E 0.0 13.387 3.465 BOR 2 25.0 1.101 EQ=1 0.0 8.01 0.1028 2.199 Vel = 8.42 BOR 2 6.997 K Factor= 3.03 H6 10 3.03 8.00 1 N 7.0 10.917 150 6.997 K = K @ EQ=1 to 2.166 0 5.0 12.000 1.505 0.0 0.0 12.705 201 10 8.0 1.101 -3 0.0 22.917 0.0125 0.287 Vel = 2.70 201 10 8.13 1 0 5.0 4.250 150 7.284 4.000 to METE -3 30.0 1.61 0.0 5.000 42.383 0.0 0.959 Vel = 4.73 202 10 16.13 1.101 0.0 9.250 0.0457 0.423 Vel = 5.44 202 10 0.0 1 2N 14.0 7.167 150 7.707 TEST -3 to 0.995 0.0 R 1.0 15.000 Vel = 12.38 0.0 203 10 16.13 1.101 0.0 22.167 0.0457 1.013 Vel = 5.44 203 10 8.87 1 0 5.0 3.583 150 8.720 to 0.0 5.000 0.0 105 10 25.0 1.101 0.0 8.583 0.1029 0.883 Vel = 8.42 105 10 0.0 1 0 5.0 2.000 150 9.603 to 0.0 5.000 0.0 106 10 25.0 1.101 0.0 7.000 0.1027 0.719 Vel = 8.42 106 10 0.0 1 213 2.0 15.000 150 10.322 to 0 5.0 7.000 0.0 8 10 25.0 1.101 0.0 22.000 0.1029 2.263 Vel = 8.42 8 10 0.0 1 8R 8.0 52.750 150 12.585 to 2N 14.0 22.000 0.0 TOR 10 25.0 1.101 0.0 74.750 0.1028 7.686 Vel = 8.42 TOR 0.0 25.00 20.271 K Factor= 5.55 H7 10 3.03 8.13 1 0 5.0 0.500 150 7.213 K = K @ EQ=1 to 0.0 5.000 0.0 201 10 8.13 1.101 0.0 5.500 0.0129 0.071 Vel = 2.74 0.0 8.720 KFactor= 3.00 201 8.13 7.284 K Factor= 3.01 H8 10 3.03 8.87 1 O 5.0 3.667 150 8.589 K = K @ EQ=1 to 0.0 5.000 0.0 203 10 8.87 1.101 0.0 8.667 0.0151 0.131 Vel = 2.99 Computer Programs by Hydratec Inc. Revision: 50.53.5 0.0 203 8.87 8.720 KFactor= 3.00 TOR 10 25.00 1 S 9.563 8.000 150 20.271 to E 3.825 13.387 3.465 BOR 2 25.0 1.101 0.0 21.387 0.1028 2.199 Vel = 8.42 BOR 2 + 5.00 5.00 1.5 2E 8.704 4.000 150 25.935 to 0.0 8.705 2.166 UG1 -3 30.0 1.505 0.0 12.705 0.0314 0.399 Vel = 5.41 UG1 -3 0.0 1.5 3E 18.133 24.250 150 28.500 to 0.0 18.133 4.000 Fixed Loss = 4 METE -3 30.0 1.61 0.0 42.383 0.0226 0.959 Vel = 4.73 METE -3 0.0 1 0.0 27.000 150 33.459 to 0.0 0.0 0.0 TEST -3 30.0 0.995 0.0 27.000 0.2359 6.369 Vel = 12.38 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen -Williams All-Star Plum & Fire Sprinkler Fluter Residence Page 6 Date 12.15.20 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe **** Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 TEST 30.00 39.828 K Factor= 4.75 Computer Programs by Hydratec Inc. Revision: 50.53.5 Hydraulic by Hyd'raCALC All-Star Plum & Fire Sprinkler 22672 Lambert St. Suite 619 Lake Forest, Ca 949-470-0072 Job Name Fluter Residence Drawing Residence Location 1808 West Oceanfront Remote Area 2 Contract 1808 Data File Design Area 2.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 All-Star Plum & Fire Sprinkler Fluter Residence HYDRAULIC DESIGN INFORMATION SHEET Name - Fluter Residence Date - 12.15.20 Location - 1808 West Oceanfront Building - Residence System No. - 2 Contractor - All Star Plumbing & Fire Sprinkler,Inc Contract No. - 1608 Calculated By - All Star Plumbing & Fire Sprinkler,I Drawing No. - 1808 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - LIGHT HAZARD Page 1 Date 12.15.20 S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (X)1 ( )2 ( )4 ( ) S )Other 72 R Residual (Psi) - T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 20 GPM System Type Listed Pres. at Start Point - 16.7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 20 x 20 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 GPM Sprinkler or Nozzle S Additional Flow Added - GPM Make Viking Model VK494 I Elevation at Highest Outlet - Feet Size K -Factor 4.9 G Note: Temperature Rating 200 N Calculation GPM Required 20.02 Summary C -Factor Used: W Water Flow Test: A Date of Test �- T Time of Test - E Static (Psi) - 72 R Residual (Psi) - 20 Flow (GPM) - 500 S Elevation - P Location: P L Source of Information Y Psi Required 34.176 Overhead 150 Pump Data: Rated Cap. @ Psi Elev. Other At Test Underground 150 Tank or Reservoir: Cap. Elev. Well Proof Flow GPM Computer Programs by Hydratec Inc. Revision: 50.53.5 N UCD�c L C O_ 7 U) T LL N fl E 7 7.- C/) a a � K N � a LL N U NN r 0 O r ONS �O� N � N m m �LLa c❑ , E E E E m uo �ytl1❑N� � LU CO U) NU) N OM (p C�-NN E m 0 0 v m ll) O < � Z 0 J LL N c O O O N �o]O O � � �N3 � y � O Ta l0 (0 p> > U U'O ILIa O O xof N O � (O�NN 9000 T O O O O O O a N (0000 O N N h O O O N M � m m Ol +� m @ vo00 v �n m o 0 0 N 000(0 O N m N000�(J m N (O V N r 000 t'l �f1 r OOON V O N O O O N rn O c M m000� V1 N c n N U J Q E m LL o m U y N LL > O ._ c > a C y LL oo m U cZ 0 o mo �LL a am d v rn m � rn ,= m U w o O J V y CO c o v o 0 m m m c O Lco m o E:E E 3 m LN.3 �� w mw� c nm Ew m m tm ali�a c�camE m f r m E m C O m L U E2 cyi-Nrnm Q0 c W N ir cu 19, 3 E n 2 c H U 3 m t ao� y U) L NCl) U m ON y=m_ c D y o J o m a m N C L LL N lL fn cD Om L z> M— y c 0 a o C M w J c,. m o y E Ea -oE a»>a `0 'cy .c Q Jm �m waaaLL E ="c mD ma�nE c 0 y a m mz z000z E � E m c0 x CO ���� ii�m�Em ii ¢LL wm Z o 0 m o Pressure / Flow Summary - STANDARD All-Star Plum & Fire Sprinkler Page 4 Fluter Residence Date 12.15.20 Node No. Elevation K -Fact Pt Actual Pn Flow Density Actual Area Press Reg. SRP1 19.0 4.9 16.7 na 20.02 0.05 400 16.7 EQ=1 19.5 16.86 na H3 19.5 K = K @ EQ=1 16.86 na 20.02 6 19.5 18.55 na 7 10.0 23.79 na 8 10.0 24.16 na TOR 10.0 29.25 na BOR 2.0 34.18 na 5.0 11G1 -3.0 36.63 na METE -3.0 41.31 na TEST -3.0 45.87 na The maximum velocity is 10.32 and it occurs in the pipe between nodes METE and TEST Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen -Williams All-Star Plum & Fire Sprinkler Page 5 Fluter Residence Date 12.15.20 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 19 4.90 20.02 1 O 5.0 0.500 150 16.700 to 0.0 5.000 -0.217 EQ=1 19.500 20.02 1.101 0.0 5.500 0.0682 0.375 Vel = 6.75 0.0 EQ=1 20.02 16.858 K Factor= 4.88 H3 19.500 4.88 20.02 1 2N 14.0 9.833 150 16.858 K = K @ EQ=1 to R 1.0 15.000 0.0 6 19.500 20.02 1.101 0.0 24.833 0.0682 1.694 Vel = 6.75 6 19.500 0.0 1 N 7.0 9.417 150 18.552 to 0.0 7.000 4.114 7 10 20.02 1.101 0.0 16.417 0.0682 1.120 Vel = 6.75 7 10 0.0 1 O 5.0 0.417 150 23.786 to 0.0 5.000 0.0 8 10 20.02 1.101 0.0 5.417 0.0681 0.369 Vel = 6.75 8 10 0.0 1 8R 8.0 52.750 150 24.155 to 2N 14.0 22.000 0.0 TOR 10 20.02 1.101 0.0 74.750 0.0682 5.098 Vel = 6.75 0.0 TOR 20.02 29.253 K Factor= 3.70 TOR 10 20.02 1 S 9.563 8.000 150 29.253 to E 3.825 13.387 3.465 BOR 2 20.02 1.101 0.0 21.387 0.0682 1.458 Vel = 6.75 BOR 2 + 5.00 5.00 1.5 2E 8.704 4.000 150 34.176 to 0.0 8.705 2.166 UG1 -3 25.02 1.505 0.0 12.705 0.0224 0.285 Vel = 4.51 UG1 -3 0.0 1.5 3E 18.133 24.250 150 36.627 to 0.0 18.133 4.000 * Fixed Loss = 4 METE -3 25.02 1.61 0.0 42.383 0.0162 0.686 Vel = 3.94 METE -3 0.0 1 0.0 27.000 150 41.313 to 0.0 0.0 0.0 TEST -3 25.02 0.995 0.0 27.000 0.1686 4.553 Vel = 10.32 0.0 45.866 K Factor = 3.69 Computer Programs by Hydratec Inc. Revision: 50.53.5 Hydraulic Calculations by HydraCALC All-Star Plum & Fire Sprinkler 22672 Lambert St. Suite 619 Lake Forest, Ca 949-470-0072 Job Name Fluter Residence Drawing Residence Location 1808 West Oceanfront Remote Area 3 Contract 1808 Data File Design Area 3.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 All-Star Plum & Fire Sprinkler Page 1 Fluter Residence Date 12.15.20 HYDRAULIC DESIGN INFORMATION SHEET Name - Fluter Residence Date - 12.15.20 Location - 1808 West Oceanfront Date of Test - Building - Residence System No. - 3 Contractor - All Star Plumbing & Fire Sprinkler,Inc Contract No. - 1808 Calculated By - All Star Plumbing & Fire Sprinkler,I Drawing No. - 1808 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - LIGHT HAZARD Other S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )l (X)2 ( )4 ( ) S )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make Viking Model VK494 I Elevation at Highest Outlet - Feet Size K -Factor 4.9 G Note: Temperature Rating 200 N Calculation Gpm Required 26.34 Psi Required 37.183 At Test Summary C -Factor Used: Overhead 150 Underground 150 W A T E R 5 P P L Y Water Flow Test: Pump Data: Tank or Reservoir: Date of Test - Rated Cap. Cap. Time of Test - @ Psi Elev. Static (Psi) - 72 Elev. Residual (Psi) - 20 Other Well Flow (Gpm) - 500 Proof Flow Gpm Elevation - Source of Information: Computer Programs by Hydratec Inc. Revision: 50.53.5 N U � M m � a j C N 3 WE ^ o 2 a Cwa Cc C E E rn E E m � .n m o- o 0 > m m p y g a OM tip CONN m000=o(n E 0 ❑ 0 0 v 0 m Co Co o< Z O J O N O O O O N V W O cO ALL) �N3 O � y � o WaLL i;a mm > > aoaa o o ❑ O n�CC ❑ U1 O �UUU 0 0 M N 0 0 U A v N m 0 0 0 O N N h 0 0 0 N M � N m m m V O O O C + N t0 O O O O V Yl (+l O O O N r � NOOO(O O N LL� N OOOIU m �[1 V N In �OOON O N !7 rn mOOO� O C N � � m V J Q ELL m> o m U w �'� a a 7 L J 75- N m��NP J N Q < O1 - c L O Z 0z c a�a > a J v y(n 3 c-oa N U C O L N O) O) N n mY EL o aci o w ma nN Eaa �+ L j �p_� Y �� � moo ALL �.o c�N E E M mo w c p a W c 0 J c a l-0 MM W a@i tY 'o20 E Y E cal) U) L -O LL N U � rn F- 0 C w m C> O CYO N KS c �' �_ .N. N Q O J (n J m c �Z N Z UUUZ E J 7 C.m. D 'E O) .C-. C O C O N V +� d N m U) � � a i,- m E m LL EamU C N O d p 0..3 LL QLL LLQ d Z W O w N Pressure / Flow Summary - STANDARD All-Star Plum & Fire Sprinkler Page 4 Fluter Residence Date 12.15.20 Node Elevation K -Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. SRP1 19.0 4.9 7.04 na 13.0 0.05 256 7.039 EQ=1 19.5 7.05 na H4 19.5 K= K@ EQ=1 7.05 na 13.0 101 19.5 7.74 na 102 19.5 8.62 na 103 10.0 14.6 na 104 10.0 17.38 na 105 10.0 19.54 na 106 10.0 20.34 na 8 10.0 22.83 na H5 19.5 K= K @ EQ=1 7.43 na 13.34 TOR 10.0 31.3 na BOR 2.0 37.18 na 5.0 UG1 -3.0 39.78 na METE -3.0 44.82 na TEST -3.0 51.73 na The maximum velocity is 12.93 and it occurs in the pipe between nodes METE and TEST Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen -Williams All-Star Plum & Fire Sprinkler Page 5 Fluter Residence Date 12.15.20 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe *** Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 19 4.90 13.00 1 N 7.0 0.500 150 7.039 K = K @ EQ=1 to 0.0 7.000 -0.217 EQ=1 19.500 13.0 1.101 0.0 7.500 0.0307 0.230 Vel = 4.38 0.0 EQ=1 13.00 7.052 K Factor= 4.90 H4 19.500 4.9 13.00 1 N 7.0 10.333 150 7.052 K = K @ EQ=1 to O 5.0 12.000 0.0 101 19.500 13.0 1.101 0.0 22.333 0.0307 0.685 Vel = 4.38 101 19.500 13.34 1 N 7.0 0.833 150 7.737 to 0.0 7.000 0.0 102 19.500 26.34 1.101 0.0 7.833 0.1134 0.888 Vel = 8.88 102 19.500 0.0 1 N 7.0 9.417 150 8.625 to 0.0 7.000 4.114 Fixed Loss = 4 103 10 26.34 1.101 0.0 16.417 0.1132 1.859 Vel = 8.88 103 10 0.0 1 N 7.0 11.583 150 14.598 to R 1.0 13.000 0.0 104 10 26.34 1.101 O 5.0 24.583 0.1133 2.785 Vel = 8.88 104 10 0.0 1 O 5.0 14.083 150 17.383 to 0.0 5.000 0.0 105 10 26.34 1.101 0.0 19.083 0.1132 2.161 Vel = 8.88 105 10 0.0 1 O 5.0 2.000 150 19.544 to 0.0 5.000 0.0 106 10 26.34 1.101 0.0 7.000 0.1133 0.793 Vel = 8.88 106 10 0.0 1 2R 2.0 15.000 150 20.337 to O 5.0 7.000 0.0 8 10 26.34 1.101 0.0 22.000 0.1133 2.492 Vel = 8.88 8 10 0.0 1 8R 8.0 52.750 150 22.829 to 2N 14.0 22.000 0.0 TOR 10 26.34 1.101 0.0 74.750 0.1133 8.467 Vel = 8.88 0.0 TOR 26.34 31.296 K Factor= 4.71 H5 19.500 4.9 13.34 1 O 5.0 4.583 150 7.429 K = K @ EQ=1 to 0.0 5.000 0.0 101 19.500 13.34 1.101 0.0 9.583 0.0321 0.308 Vel = 4.50 0.0 101 13.34 7.737 K Factor= 4.80 TOR 10 26.34 1 S 9.563 8.000 150 31.296 to E 3.825 13.387 3.465 BOR 2 26.34 1.101 0.0 21.387 0.1132 2.422 Vel = 8.88 BOR 2 + 5.00 5.00 1.5 2E 8.704 4.000 150 37.183 to 0.0 8.705 2.166 UG1 -3 31.34 1.505 0.0 12.705 0.0340 0.432 Vel = 5.65 UG1 -3 0.0 1.5 3E 18.133 24.250 150 39.781 to 0.0 18.133 4.000 Fixed Loss = 4 METE -3 31.34 1.61 0.0 42.383 0.0246 1.041 Vel = 4.94 METE -3 0.0 1 0.0 27.000 150 44.822 to 0.0 0.0 0.0 TEST -3 31.34 0.995 0.0 27.000 0.2557 6.905 Vel = 12.93 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen -Williams All-Star Plum & Fire Sprinkler Page 6 Fluter Residence Date 12.15.20 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe *****"" Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 TEST 31.34 51.727 K Factor= 4.36 Computer Programs by Hydratec Inc. Revision 50.53.5