HomeMy WebLinkAboutF2021-0438 - Miscl� lam) l C�- Model F1 FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1 FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1 FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1 FR40 Sprinkler Types Standard Spray Pendent Model F1FR42, FiFR40, FIFRXLH & FlFR28 Recessed Sprinkler Types Standard Spray Pendent Model F1 FR56LL & F1 FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1 FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. 1. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL199. 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. VdS Schadenverhiitung GmbH (VdS) 5. Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) 6. EC Certificate: 0786 -CPD -40239 (RA1414), 0786 - CPD -40251 (RA1425), 0786 -CPD -40252 (RA1475) (EC) 7. WaterMark certified. Certificate Number 23347. (WM) LIL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Model F1 FR Series Quick Response Glass Bulb Sprinklers Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed PendenUF1/F2 Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright. :,XLH Pendent XLH Recessed Pendent F1/F2 Product Description Reliable Model F1 FR series sprinklers are quick -response automatic sprin- klers with a glass bulb thermal element. Model F1 FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model F1 FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1 FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR Series sprinklers to apply water to afire faster than standard -response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 0 A 0 0 6 (D N 0 N 0 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1 FR Series sprinklers provide a wide range of op- tions where quick -response, glass bulb sprinklers are used: • Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors • K -factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) • Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1 FR series sprinkler configurations. Model F1 FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4 -inch (19mm) and 1/2 -inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2 -inch (12.7mm) threaded adjustment. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2 -inch (12.7mm) of cover plate adjustment: Jr.,'addition, a low profile Model CCP cover plate is also available that provides up to 5/16 -inch (8.Omm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k -factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1 FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 Ib -ft (11 to 24 N -m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1 FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers have a factory -installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2 -inch (13mm) or 5/8 -inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1 FR Series Concealed Pendent sprinklers require a 2 -5/8 -inch (67mm) diameter hole to be out in the ceiling. The Model GFR2 wrench is used to engage the sprinkler wrench- ing surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good .fire pro- tection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick -response Thread Size: 1/2 -inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. 0) Available with FM approved Polyester coating in black or. white. (0 Available with LPCB and VdS approved Polyester coating. (o VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 1557 (68°C) temperature rated sprinklers only. Vd5 approved sprin- klers must use Norbulb brand glass bulbs with the 1/2 -inch (12.7mm) adjustment Model CCP cover plate only. (o Model F1 FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2 -inch (12.7mm) of adjustment or low profile with 5/16 -inch (8.0 mm) of adjustment. X11 cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1 FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (e) cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. 0) The F1 FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the FIFR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Design and Installation Information Model Nominal K -factor Nominal Orifice Diameter. Deflector/ Orientation Nominal Sprinkler Height. inches mm Installation -Wrench SIN Listings and Approvals Approval Notes US Metric inches mm Pendent 2.25 57 W2 RA1411 cULus 2 F1 FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2. RA14181 VdS Pendent 2.25 57 W2 RA1413 cULus 2 F1 FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 FlFR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH FIFRXLH Pendent 2.25 57 W2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 Pendent 2.25 57 W2Im cULus, FM, LPCB, VdS, EC, 1,2,3,4 WM cULus, FM, Recessed Pendent 2.25 57 GFR2 RA1414 LPCB, VdS, EC, 1,2,3,4 WM FlFR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 GFR2 RA1414 cULus VdS,EC, WM 5,6 cULus, FM, Upright 2,25 57 W2 RA1425 LPCB, VdS, EC, 1,2,3,4 WM "Conventional (Pendent or Upright)" 2 25 57 W2 RA1475 LPCB, VdS, EC, 4 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 FIFR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 2.25 57 GFR2 IRA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 FlFR56 5.6 80 1/2 15 Recessed Horizontal Sidewall 2,63 67 GFR2 RA1435 cULus, FM 8 FlFR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB 1 2 3 9 (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. 0) Available with FM approved Polyester coating in black or. white. (0 Available with LPCB and VdS approved Polyester coating. (o VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 1557 (68°C) temperature rated sprinklers only. Vd5 approved sprin- klers must use Norbulb brand glass bulbs with the 1/2 -inch (12.7mm) adjustment Model CCP cover plate only. (o Model F1 FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2 -inch (12.7mm) of adjustment or low profile with 5/16 -inch (8.0 mm) of adjustment. X11 cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1 FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (e) cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. 0) The F1 FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the FIFR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings * Model F1 FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Model FP 100°F (38°C) Max. Ambient 150°F (65°C) Max. Ambient 225°F (107°C) Max. Model Deflector/ . Temp. Ambient Temp. OrientationTem 135-F (57°C) 155°F (68°C) 175-F (79°C) 200°F (93°C) 286°F (141°C) Temp. Temp. Ratinq Temp. Rating Temp. Rating Temp. Rating Rating adjustment Orange Bulb I Red Bulb Yellow Bulb Green Bulb Blue Bulb cU-us Pendent cU-us F1 FR28 Recessed Pendent cULus Recessed Pendent Upright cULus VdS Pendent VdS F1 FR40 Recessed Pendent VdS Recessed Pendent Pendent cULus F1 FR42 Recessed Pendent cU-us RA1413 Upright cULus FIFR42LL Pendent cULus, ULH cU-us, ULH Recessed Pendent cULus, ULHINEW Pendent cULus RA1410 FI FRXLH Recessed Pendent cU-us cU-us Upright cU-us cULus Pendent cULus, FM, -PCB, VdS EC WM Fl FR56 Recessed Pendent cULus, FM, -PCB, VdS, EC, WM CuLus, LPCB, VdS, cULus, FM, LPCB, Concealed Pendent* cU-us, WM ` WMS,EC' cU-us, WM F1 FR56 EC, WM VdS, EC, WM Upright cULus, FM, -PCB, VdS, EC, WM Recessed Pendent "Conventional LPCB, VdS, EC, WM cULus, ULH Pendent or Upright)" ad Pendent cU-us, ULH FIFR66LL Recessed Pendent cU-us, ULH cULus, FM Concealed Pendent* cU-us, ULH Horizontal Sidewall cU-us, FM F1 FR56 Recessed Horizontal cU-us, FM Sidewall F1 FR56 Vertical Si . w Pen- cULus, FM, LPCB dent o * Model F1 FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data 13 Listed and Approved Recessed Escutcheons Model F1 Model F2 Model FP Model Deflector/ (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN Orientation 3/4 -inch (19mm) 1/2 -inch (12.7mm) 1/2 -inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cU-us cU-us cULus RA1411 F1 FR40 Recessed Pendent VdS VdS VdS RA1418 F1 FR42 Recessed Pendent cU-us cULus cU-us RA1413 FlFR42LL Recessed Pendent cU-us, ULH cU-us, ULH cU-us, ULH RA1410 FIFR42XLH Recessed Pendent cU-us cU-us cULus RA1413 Fl FR56 Recessed Pendent CuLus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC, WM EC, WM VdS, EC, WM FIFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH ad F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus 13 2 1/4" HOLE DIA. -y [5Z2mmJ 1 15/16" DA / [49.2mm] I � - - - - - - - - TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER t WRENCH 6055 \ / � I � I II II - II 4- F1 �Ia ESCUTCHEO ADJUSTMENT 00 VE F2 ESCUTCHEON 1/2'(72.7mm] ADJUSTMENT �� 2 27/32" DA [722mm] 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = ] [25.4mm] AT MINIMUM RECESS = 3/8 [9.5mm] / F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'[79mm] AT MINIMUM RECESS = 3/8'T9.5mm] F1 ESCUTCHEON Model 171 FR56, F1 FR561-1-, F1 FR42, F1 FR40, F1FR421-1-, F1 FRXLH & P1FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon 2 5/8" DIA. [66.7mm] HOLE IN CEILING 2 5/16" DIA. [58.7mm] CUP CEILING !12 [12.7mm] ADJUSTMENT 3 114" DIA. [82.6mm] 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = i-112[J8mm] AT MINIMUM RECESS = 1 [25.4mm] AT MAXIMUM RECESS = 9/16[14.3mm] AT MINIMUM RECESS = 1 [25.4mm] Model F1 FR56, F1FR561-L,F1FR42,F1FR40,F1FR421-1,FIFRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon M AT MAXIMUM RECESS = 7/8'T22.2mm] [J2mm) AT MINIMUM RECESS F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'T28.6mm] AT MINIMUM RECESS = 1-5/8'T41.3mm] Model 171 FR56, F1 FR561-1-, F1 FR42, F1 FR40, F1FR421-1-, F1 FRXLH & P1FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon 2 5/8" DIA. [66.7mm] HOLE IN CEILING 2 5/16" DIA. [58.7mm] CUP CEILING !12 [12.7mm] ADJUSTMENT 3 114" DIA. [82.6mm] 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = i-112[J8mm] AT MINIMUM RECESS = 1 [25.4mm] AT MAXIMUM RECESS = 9/16[14.3mm] AT MINIMUM RECESS = 1 [25.4mm] Model F1 FR56, F1FR561-L,F1FR42,F1FR40,F1FR421-1,FIFRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon M FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1'[25.4mm] AT MINIMUM RECESS = 3/8'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS=3/4[19mm] AT MINIMUM RECESS = 3/8 [9.5mm] 2 1/4" HOLE DIA. [57.2mm) 1" X 1/2" REDUCER [3.2-m) F1 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8 [34.9mm] AT MINIMUM RECESS = 2-1/16[52.4mm) F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'T41.3mm1 AT MINIMUM RECESS = 2-1/i 6'T52.4mm] 1 15/16" 49.2mm [ ) nni 2 27/32 DIA. uni 4" [72.2mm) � ion TURN COLLAR UNTIL � r TIGHT AGAINST SPRINKLER 09Stl0 WRENCH BOSS. F1 ESCUTCHEON —_ 3/4719mm] ADJUSTMENT F2 ESCUTCHEON 1/2'T12.7mm] ADJUSTMENT y (1) 4"-12" [101.6mm-304.8mm] CEILING TO DEFLECTOR RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model F1FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon 1 " x 7/2" REDUCING TEE OR ELBOW 2 5/16" DIA — CUP � — 2 5/8" DIA. HOLE. IN CEILING 1/2" MAX. / 15/76" COVER ADJUSTMENT/ COVER PLATE — —),— ASSEMBLY 3 5/16" DIA. SPRINKLER CONCEALED, 1/2' ADJUSTMENT OAPCOIA Fig. 4 Model F1 FR56/171 FR56LL Concealed Pendent sprinkler with standard depth 1/2 -inch (12.7mm) adjustment- Model CCP cover plate 91 09Stl0 1 1/2" MAX. "q FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING��� 1/2" MAX. / 15/76" COVER ADJUSTMENT/ COVER PLATE — —),— ASSEMBLY 3 5/16" DIA. SPRINKLER CONCEALED, 1/2' ADJUSTMENT OAPCOIA Fig. 4 Model F1 FR56/171 FR56LL Concealed Pendent sprinkler with standard depth 1/2 -inch (12.7mm) adjustment- Model CCP cover plate 91 I" x 1/2" REDUCING TEE OR ELBOW 25/76"DIA = CUP - 2 5/8" DIA. HOLE IN CEILING yy 1 1/2" MAX. Frame: FACE OF FITTING EscutcheonCover TO FACE OF CEILING :F7 %; %% DIMENSION 5/16" MAX. J 3/4'" COVER ADJUSTMENT i j COVER PLATE ASSEMBLY 3 SPRINKLER CONCEALED 5/16" ADJUSTMENT 017FGOM 5/16 -inch (8.Omm) adjustment - Model CCP cover plate Maintenance The Model F1 FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) (1) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi -gloss, unless specified otherwise. c) cULus Listed only. A 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414. (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RAI 414, RAI 435 and RA1425 in standard black or white. �sll _PCB and VdS Approved finish applies only to RA1425, RA1414, 841418 (VdS) and RA1475. cULus listed Corrosion Resistant Standard Finishes Frame: S rinkler EscutcheonCover latel't Bronze Brass Chrome Chrome Plated Chrome Plated I White Polyester Coated MW) White Painted S ecial Aonlication Finishes Sprinkler Escutcheon Cover plateM Electroless Nickel PTPE7) Electroless Nickel PTFE Bright Brass Bright Biased) Bright Brass Black Platin Black Plated Black Plated Black Paint Black Paintc)(') Black Paint Off White Off White(2)(s) Off White Satin Chrome Chrome Dull Chrome Dull (1) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi -gloss, unless specified otherwise. c) cULus Listed only. A 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414. (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RAI 414, RAI 435 and RA1425 in standard black or white. �sll _PCB and VdS Approved finish applies only to RA1425, RA1414, 841418 (VdS) and RA1475. cULus listed Corrosion Resistant Ordering Information Specify: 1. Sprinkler Model: [F1FR28)[F1FR40][F1FR42] [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2 -inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135°F (570C)1[155°F (680C)][175°F (79°C)1[200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model:[F1][F2][FPl 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2 -inch (12.7mm) adjustment][low profile CCP 5/16 -inch (8.Omm) adjustment] 9. Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][ 165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Material Data Frame: DZR Brass, OM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: 1. Sprinkler Model: [F1FR28)[F1FR40][F1FR42] [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2 -inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135°F (570C)1[155°F (680C)][175°F (79°C)1[200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model:[F1][F2][FPl 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2 -inch (12.7mm) adjustment][low profile CCP 5/16 -inch (8.Omm) adjustment] 9. Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][ 165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. ® Recycled (800) 431-1588 Sales Offices Paper Rell ab'� (800) 848-051 Sales Fax Revision lines indicate updated or new data. (914) 829-22042 Corporate Offices www.reliablesprinklercom Internet Address EG. mimed in U.S.A. 10/20 P/N 9999970,900