HomeMy WebLinkAboutPV2022-134 - CalcsD72 v ENGINEERS Ma 4, 2022 Sunrun Inc. 133 Technology Dr, Suite 100 Irvine, CA, 92618 Attn.: To Whom It May Concern re: Job 22-05541 : CHRIS SORENSEN-109R-600SORE IZ%3 - 2 OW- Pvu22- t5y (U00 Wit un. The following calculations are for the structural engineering design of the photovoltaic panels located at 1600 KENT LN, NEWPORT BEACH, CA 92660. After review, PZSE, Inc. certifies that the roof structure has sufficient structural capacity for the applied PV loads. BUILDING DIVISION May 16 2022 BY: S.E.C. If you have any questions on the above, do not hesitate to call. Prepared By: PZSE, Inc. - Structural Engineers Roseville, CA BEACH, Na 53873 'W 3,31-23 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience I Integrity I Empowerment ® Project: CHRIS SORENSEN -- Job #: 22-05541 Date: 5/4/2022 Engineer: MR Gravity Loading Ru p 'A I i I ps = Ground Snow Load = psf Ce= Exposure Factor= 0.9 ASCE 7-16 Table 7.3-1 Cr=Thermal Factor= 1.1 ASCE 7-16 Table 7.3-2 1 = Importance Factor = 1 pt = 0.7 Ce Ct I ps psf ASCE 7-16 Eq 7.3-1 where ps 5 20 psf, Pr min = I x ps = N/A where ps>. 20 psf, Pr min= 20 x I = N/A Per ASCE 7-16, minimum values of Pf shall apply to hip and gable roofs with slopes less than 15-. Therefore, pr= Flat Roof Snow Load = psf P, = C,pr ASCE 7-16 Eq 7.4-1 Cs = Slope Factor = 1.000 ARRAY 1 Cs = Slope Factor = 1.000 ARRAY 2 Ps= Sloped Roof Snow Load= 0.0 psf ARRAY Ps = Sloped Roof Snow Load = 0.0 psf ARRAY 2 3 ARRAY 1 ARRAY 2 Note: Roof live load is removed in area's covered by PV array. Composition Shingle 4.00 Plywood and ixT&G Decking 4.00 2x6 Rafters @ 24"o.c. 0.76 Vaulted Ceiling 0.00 Ceiling Not Vaulted Miscellaneous 0.24 Total Roof DL ARRAY 1 9.0 psf DL Adjusted to 20 Degree Slope 9.6 psf Composition Shingle 4.00 Plywood and 1xT&G Decking 4.00 2x6 Rafters @ 24"o.c. 0.76 Vaulted Ceiling 0.00 Ceiling Not Vaulted Miscellaneous 0.24 Total Roof DL ARRAY 2 9.0 psf DL Adjusted to 20 Degree Slope 9.6 psf 2of6 E Project: CHRIS SORENSEN -- Job #: 22-05541 Date: 5/4/2022 Engineer: MR Wind Calculations Per ASCE 7-16 Components and Cladding Wind Speed 95 mph Exposure Category B Roof Shape Gable Roof Slope - 20 degrees Mean Roof Height lift Building Least Width 36 ft Effective Wind Area 16.4 sf Roof Zone Edge Distance, a 3.6 ft Panel to Building Edge, di 5.5 ft Array Edge Factor Length 8.2 ft Controlling C&C Wind Zone Zone 3 Pressure Equalization Factory, 0.71 Wind Pressure P=qh*(G*Cp)*ye*ya qh = 0.00256 * Kz * Kzt * Kd *Ke* VA2 Eq. 26.10-1 Kz (Exposure Coefficient) = 0.7 Table 26.10-1 Kzt (topographic factor) = 1 26.8 (Figure 26.8-1) Kd (Wind Directionality Factor) = 0.85 Table 26.6-1 Ke (Elevation Factor)= 1.00 26.9 V (Design Wind Speed) = 95 mph Fig. 26.5-18 Risk Category = II Table 1.5-1 qh = 13.7 psf 0.6*qh=8.22 Zone 1 Zone 2 Zone 3 Positive GCp= -2.00 -2.69 3.21 0.49 Uplift Pressure = -11.67 psf -15.72 psf -18.76 psf 16.00 psf Uplift Edge Pressure= -17.51 psf -23.59 psf -28.15 psf 24.00 psf Attachment Dead Load = 3.00 psf 3.00 psf 3.00 psf Max Rail Span Length= 6.00 6.00 6.00 Max Rail Span Length Edge = 6.00 0.00 0.00 Longitudinal Length = 2.73 2.73 2.73 Attachment Tributary Area= 16.38 16.38 16.38 Attachment Tributary Area Edge= 16.38 0.00 0.00 Attachment Uplift = -162.00 -228.00 -278.00 Attachment Uplift Edge= -257 0 0 _,.Eea!41rP ..ao.. Fastener = 5/16 inch Number of Fasteners =l Minimum Threaded Embedment Depth = 2.5 inch Withdraw Capacity Per Inch = 205 lb NDS Eq 12.2-1 Allowable Withdraw Capacity= 820lb lb NDS Eq 11.3-1 820 lb capacity> 278 lb demand Therefore, OK Embedment Depth Reduction Factor 1 Lateral Force from Gravity Loads= 17 lb Attachment Lateral Capacity= 250lb lb NDS Table 12K 250lb capacity> 17lb demand Therefore, OK 3of6 E Project: CHRIS SORENSEN -- Job #: 22-05541 Date: 5/4/2022 Engineer: MR Framing Check ARRAY 1 PASS w = 193 plf Dead Load 9.6 psf PV Load 3.0 psf Live Load 19.6 psf Member Span =10' - 9" Governing Load Comb. DL+ LL Total Load 32.2 psf 2x6 Note: Attachments may be Unstaggered. 22.69 62.39 SPF#2 Fb (psi) = f'b x Cd x Cf x Cr 875 x 1.25 x 1.3 x 1.15 Allowed Bending Stress = 1635.1 psi Maximum Moment = (wLA2)/8 = 2788.44 ft# = 33461.3 in# Actual Bending Stress = (Maximum Moment) / S = 1474.9 psi Allowed > Actual -- 90.3% Stressed -- Therefore, OK Deflection Criteria Based on = Actual Deflection (Total Load) _ Allowed Deflection (Live Load) _ Actual Deflection (Live Load) _ L/120 (E _ = 1.074 in Simple Span (5*w*LA4) / (384*E*I) = 0.663 in = L/195 < L/120 Therefore OK L/180 0.716 in (5*w*LA4)/(384*E*I) 0.404 in L/320 < L/180 Therefore OK mber Spacing @ 24" o.c. N Member Area = 24.8 inA2 Fv (psi) = 135 psi (NDS Table 4 Allowed Shear = Fv * A = 3341 lb Max Shear (V) = w * L / 2 = 346 lb Allowed > Actual --10.4%Stressed -- Therefore, OK 4of6 PZ® Project: CHRIS SORENSEN -- Job #: 22-05541 Date: 5/4/2022 Engineer: MR Framing Check ARRAY 2 PASS w = 193 plf Dead Load 9.6 psf PV Load 3.0 psf Live Load 19.6 psf k6Rer14 o"e^3 Member Span =10' - 2" Governing Load Comb. DL+LL Total Load 32.2 psf Note: Attachments may be Unstaggered. 2x6 _ 22.69 62.39 SPF#2 @ 24" o.c. Fb (psi) = f'b x Cd x Cf x Cr 875 x 1.25 x 1.3 x 1.15 Allowed Bending Stress = 1635.1 psi Maximum Moment = (wLA2) / 8 = 2495.4 ft# = 29944.8 in# Actual Bending Stress = (Maximum Moment) / S = 1319.9 psi Allowed > Actual -- 80.8% Stressed -- Therefore, OK = U120 (E = 1400000 psi Per NDS) Deflection Criteria Based on = Actual Deflection (Total Load) _ Allowed Deflection (Live Load) _ Actual Deflection (Live Load) _ = 1.016 in Simple Span (5*w*LA4) / (384*E*I) = 0.531 in = L/230 < L/120 Therefore OK L/180 0.677 in (5*w*LA4) / (384*E*I) 0.324 in L/377 < L/180 Therefore OK Member Area = 24.8 inA2 Fv (psi) = 135 psi (NDS Table 4 Allowed Shear = Fv * A = 3341 lb Max Shear (V) = w * L/ 2 = 327lb Allowed > Actual -- 9.9% Stressed -- Therefore, OK 5of6 DZE Project: CHRIS SORENSEN -- Job #: 22-05541 Date: 5/4/2022 Engineer: MR Lateral Check: 2019 CEBC Level Area Weight (psf) Weight (Ib) Roof 1728 sf 9.6 psf 16589 lb Ceiling 1728 sf 6.0 psf 10368lb 7/8".Stucco 672 sf 11.0 psf 7392 lb (8' Wall Height) Int. Walls 336 sf 6.0 psf 2016 lb Existing Weight of Effected Building 36365 lb Weight of PV System (Per Sun run Inc.) 3.0 psf - Approx. Area of Proposed PV System 338 sf - Approximate Total Weight of PV System 1014lb 10%of Existing Building Weight (Allowed) 3636lb Approximate Weight of PV System (Actual) 1014 lb Percent Increase 2.8% 3636lb > 1014 lb, Therefore OK Per 2019 CEBC §502.5 & 503.4, the increase in the lateral demand/capacity ratio of the existing structure due to the installation of the PV system is less than 10%. Therefore, the existing structure may remain unaltered. 6of6