Loading...
HomeMy WebLinkAboutX2022-0386 - MiscSTATE OF CALIFORNIA MECHANICAL CEC-NRCI-MCH-01-E (Revised 01/20) Wiz- m CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-MCH-01-E Mechanical (Page 1 of 2) Pmj-RName: Blrtcher Development Enforcement Agenry: Permit Number: PmleciAaarc„` 450 Newport Center Drive Car' Newport Beach zip Cede: 92660 A. GENERAL INFORMATION DATE OF BUILDING PERMIT: Applicable Sheets or Pages, Tables, Schedules, etc. BUILDING TYPE ❑ Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel PHASE OF ❑New Construction 13 Addition ®Alteration CONSTRUCTION If more than one person has responsibility for building construction, each person shall prepare and sign an Installation Certificate document applicable to the portion of construction for which they are responsible; alternatively, the person with chief responsibility for construction shall prepare and sign the Installation Certificate document(s) for the entire construction. B. SCOPE OF RESPONSIBILITY Date of approval by the enforcement agency of the Certificate of Compliance that provides the Date: specifications for this Installation Certificate. In the table below identify all applicable construction documents that specify the features, materials, components, manufactured devices, or system performance diagnostic results required for the scope of responsibility for this Installation Certificate. Document Title or Description Applicable Sheets or Pages, Tables, Schedules, etc. Date Approved By the Enforcement Agency HVAC PLAN 450NCD.0200.M1 - 450NCD.0200.M3 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance January 2020 STATE OF CALIFORNIA MECHANICAL CEC-NRCI-MCH-01-E (Revised 01/201 CERTIFICATE OF INSTALLATION NRCI-MCH-01-E Mechanical (Page 2 of 2) Proled Name: Birtcher Development Enforcement Agency: Permit Number. Prolec,Addms: 450 Newport Center Drive car Newport Beach zrocde: 92660 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Dennie Brisco Documentation Author Signature: Dennis Brisco Documentation Author Company Name: HVAC Mechanical Date Signed: 5/13/22 Address: 446 W. Crowther Ave. CEA/ HERS Certification Identification (if applicable): n/a City/State/Zip: Placentia Ca 92870 Phone: 714-937-5305 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and 1 have ensured that the requirements that apply to the construction or installation have been met. S. I will ensure that a completed signed copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner atoccupancy. Responsible Builder/installer Name: Dennis Bris cs Responsible Builder/installer Signature: Dennie Brisco Company Name:Lq?$ccCrtactor or General Contractor or Builder/Owner) .(1llsta Position With Company (Title): Project Manager 440 W. Crowther Ave Csw License: 682002 city/state/zip: Placentia Ca. 92870 Phone: 714-937-5305 Date signed: 5/13/22 CA Building Energy Efficiency Standards- 2019 Nonresidential Compliance January 2020 CERTIFICATE OF INSTALLATION—USER INSTRUCTIONS NRCI-MCH-01-E Mechanical (Page 1 of 1) NRCI-MCH-01 User Instructions Section A. General Information 01. Enter the date on the building permit. 02. Indicate the appropriate building type. 03. Indicate the appropriate phase of construction. Section B. Scope of Responsibility O3. Enter the date the enforcement agency approved the Certificate of Compliance (NRCC-MCH-XX) that is used as the basis of the specifications used to demonstrate compliance. 02. Enter the construction document that specifies the installed feature, material, component, manufactured device or system performance diagnostic results required for compliance as specified on the certificate of compliance. 03. As needed, this row shall be filled according to the instructions for row B.02 04. As needed, this row shall be filled according to the instructions for row B.02 05. As needed, this row shall be filled according to the instructions for row 8.02 CA Building Energy Efficiency Standards- 2019 Nonresidential Compliance January 2020 440 W. Crowther Ave. Placentia, CA 92870 Ph:(714) 937-5305 TEST AND BALANCE ANALYSIS REPORT Bircher Development 450 Newport Center Drive, Suite 450 Newport Beach, CA G- John Anderson, President HVAC Mechanical Air Balance Report meets TABB and NEBB Standards Contractor: H.v.A.C. Mechanical, Inc. JOB# 9699 COMPLETION DATE: May 19th 2022 Tech: DJ Carlton * UNLESS OTHERWISE NOTED, INDICATED CFM IS AT STANDARD CONDITIONS. " FLOW HOOD USED ON ALL CEILING SUPPLY AND RETURN TERMINAL UNITS, AND SIDEWALL REGISTERS AND GRILLES WHERE APPLICABLE. Page 1 MASTER CODE SHEET CSD = CEILING SUPPLY DIFFUSER CEG = CEILING EXHAUST GRILLE CER = CEILING EXHAUST REGISTER CRG = CEILING RETURN GRILLE CSR = CEILING SUPPLY REGISTER CRR = CEILING RETURN REGISTER EDO = EXHAUST DUCT OPENING EAR = EXHAUST AIR REGISTER FEG = FLOOR EXHAUST GRILLE FER = FLOOR RETURN REGISTER FRG = FLOOR RETURN REGISTER FSR = FLOOR SUPPLY REGISTER RAB = RETURN AIR BAR RAG = RETURN AIR GRILLE RDO = RETURN DUCT OPENING RLD = RETURN LINEAR DIFFUSER SAB = SUPPLY AIR BAR SDO = SUPPLY DUCT OPENING SLD = SUPPLY LINEAR DIFFUSER WE = WALL EXHAUST GRILLE WE = WALL EXHAUST REGISTER WR = WALL RETURN GRILLE WR = WALL RETURN REGISTER WS = WALL SUPPLY GRILLE WS = WALL SUPPLY REGISTER GENERAL REPORTING CODES DNA = DATE NOT AVAILABLE DNL = DATA NOT LICENSED NA = NOT ACCESIBLE NI = NOT INSTALLED NS = NOT SPECIFIED NT = NOT TESTED DUE TO ABNORMAL CONDITIONS NVL = NO VALID LOCATION FOR ACCURATE TESTING = MEASURED WITH FLOW HOOD Page 2 kum "owo 440 W. Crowther Ave. Placentia, CA 92870 Ph:(714) 937-5305 FLOW HOOD HOOD: A COLLECTOR TYPE WHICH READS IN CFM 440 W. Crowther Ave. Placentia, CA 92870 Ph:(714) 937-5305 METER: ALONOR VELOMETER WITH EIGHT RANGE SELECTIONS, THREE EACH FOR SUPPLY AND RETURN. ONE POSITION SELECTOR IS ADJUSTABLE TO CORRECT FOR ALTITUDE AND TEMPERATURE. THE OTHER TWO CALIBRATED AND SEALED TO READOUT DIRECTLY IN CUBIC FEET PER MINUTE AT CONSTANT VOLUME STANDARD CONDITIONS. RANGE: 30-500, 100-1000, 200-2000 0-500, 200-1000, 500-2000 FLOW SENSOR: DUAL %" DIA. PIEZOMETER GRID SUSPENDED AT RADIUS OF AVERAGE VELOCITY. Page 3 CERTIFICATE OF CALIBRATION 440 W. Crowther Ave. Placentia, CA 92870 Ph:(714) 937-5305 ORIVIA R, WAC MECHANICAL: PLACENTIA, CA CALIBRATION CATS 03/162022 Pe, NUMBER, N/A CRLIBRAnox DDE: 03/152023 IxST. MANUFACTURER: TSI IALNOR PlaccouRa: NAVAIR I7 -2011G02 IxFT. DESCRIPnox, BALOMETER CAUSHATIGNFWID, AIR Q I4.T PSI MT MODELNUMBEh EST -731 RECEIVEDCONDITIONF: WITHIN MFG. SPECS SaU NUMBER, EB1731510004 La"COMDIT1ONSt WITHIN MFG. SPECS RATED ACCURACY, SEE NOTES- "MIRITCONDITIONSt 763mmHGA45%RH69'F UNCERTAIRTYGIVEN: 10.796%RD K=2 CERTRIMInin e'. 486770.2022 NOTES: VEL't 3%RD-t7"MIN — PROS :±.2%RD; ±oV H2O—VOL ±3%♦±7 FTIMIN—TEMP :±0.5'F— RH% t±3%RD. O:MAMUAL IM 2.0 REV 2020.2 DATED 747.2020 •a•a DECISION RULE : NO PFA% STANDARDS USED• CALIBRATED WITH DMC ACCESORIES --I AIRFOIL OM STD GRID DM STD. EBT 731 1STD. INDICATED ACTUAL INDICATED ACTUAL INDICATED ACTUAL Fr/MIN FT/MIN FT/MIN FT/MIN I "N20 -H20 114 116 52 53 0.00 0.000 53B 543 129 130 1.02 1.020 1062 1071 506 510 5.15 5.152 1541 1554 04"1057 10.18 10.159 2485 2506 1571 1524 12.24 12.253 j 4986 �j 5042 2497 2520 14.95 14.978 UUT iMD. DMSTO. UUT DM STD UUT DMSTD !- PITOT ACTUAL IND. ACTUAL IND. ACTUAL FT/MIN FY/MIN 'F 'F RH% RH% 2566 2583 ms 66.1 32.7 33.1 6438 6494 70.4 70.3 76.3 1 77.3 STANDARDS USED• --I A220: 12'WIND TUNNELO-8000 FPM I CMC±0.203% RD I TRACE# 13294076_28_ DUEJ04101/2M 102023 A24: HART SCIENTIFIC TEMP. STANDARD I±0.024 F TRACE#t6t7259390 DUEL321: CEC PRESSURE STD. O-600 PSI I to.011% RD I TR2022IA382 HUMIDITY CHAMBER STANDARD I±9.18%RH% I TRACE#1520423238 1446135470 DUE102023 I All instnnnents used in the performance of the shown calibration have traceability to the National Institute of Standards and Technology (NIST). The uncertainty ratio between the calibration standards (DM.STD.) and the Unit Under Test (UUT) is a minimum of4:1, unless otherwise noted. Calibration .has been perforrned according to the shown procedure. The use of1AS/ILAC logo indicates calibrations are in accordance to ISO/IEC 17025:2017. Dick Monne Company • 11133 Winners Circle, Los Alamitos, CA 90720 Phone: 714827-1215 • w .dickmmnns.com TMs Caabmtlaa Ceetl@otv Mv0l nat he reproduced.=,% I. fulk without approval by 1H kMunro Cumpvny. The dam,hvuv appaea ovly Iv the Inshument being Faahrated and under tlm M.I.d mvdltlon, of nObrallov. Issuing Date: Approved By: Cal. Technician: Calibrated at: /Lab _ On -Site (Customer's) 2,7—, (��e�,Ql�r/ rt%t is Page of� Page 4 DIFFUSER & GRILLE TEST SHEET 440 W. Crowther Ave. Placentia, CA 92870 Ph:(714) 937-5305 --- - ---SYSTEM- SYSTEM: VAV 1 REQUIRED ACTUAL REQUIRED ACTUAL ROOM NO. CODE SIZE(") EFF. AREA FPM CFM FPM CFM MINIMUM MINIMUM 206 1 CSD 12 550 545 206 2 CSD 12 550 545 TOTAL 12 1100 1090 330 330 --- - ---SYSTEM- SYSTEM: VAV 4 REQUIRED ACTUAL REQUIRED ACTUAL ROOM NO. CODE SIZE (") EFF. AREA FPM CFM FPM CFM MINIMUM - MINIMUM 204 1 CSD 12 600 590 203 2 CSD 12 600 600 TOTAL 1200 1190 360 360 --- - ---SYSTEM- VAV5 REQUIRED ACTUAL REQUIRED ACTUAL ROOM NO. CODE SIZE (") I EFF. AREA I FPM I CFM FPM CFM MINIMUM MINIMUM 204 1 CSD 10 400 405 203 2 CSD 10 400 405 TOTAL 800 810 240 240 Page 5 �� ka -®?� 440 W. Crowther Ave. Placentia, CA 92870 Ph:(714) 937-5305 Page 6 SYSTEM: VAV 6 REQUIRED REQUIRED ACTUAL REQUIRED ACTUAL ROOM NO. CODE SIZE (") EFF. AREA FPM CFM FPM CFM MINIMUM MINIMUM 201 1 CSD 8 150 150 200 2 CSD 10 250 255 212 3 CSD 10 350 350 TOTAL 4 CSD 8 750 755 230 230 Page 6 SYSTEM: VAV 7 REQUIRED ACTUAL REQUIRED ACTUAL ROOM NO. CODE SIZE(") EFF. AREA FPM CFM FPM CFM MINIMUM MINIMUM Hallway 1 CSD 10 400 400 211 2 CSD 8 200 205 210 3 CSD 8 200 205 209 4 CSD 8 200 205 TOTAL 1000 1015 300 300 Page 6 Compliance Results: COMPLIES Enforcement Agency Use: Checked by/Date SHUT-OFF LIGHTING CONTROL ACCEPTANCE DOCUMENT Intent: This document is used to demonstrate compliance with acceptance requirements in §130.4(a)4 and Reference Nonresidential Appendix NA7.6.2 for shut-off lighting controls. Attach additional sets of pages 1 through 2, as required, for all controls that must be tested. Indicate all types of shut-off controls tested for this project: r Automatic time switch lighting controls (Sections A-1 and B-1 of this document should be completed) F Occupant sensing lighting controls (including occupant sensors, partial -ON occupant sensors, partial -OFF occupant sensors, and/or vacancy sensors) (Sections A-2 and B-2 of this document should be completed) A-1. Automatic Time Switch Lighting Control Construction Inspection (NA7.6.2.4) I- a. Automatic time switch controls are programmed with acceptable weekday, weekend, and holiday (if applicable) schedules. (NA7.6,2.4(a), §110.9(b)lAii, §130.1(c)IA, §130.1(c)4) F b. Document for the owner weekday, weekend, and holidays schedules, as well as all set-up and preference program settings. (NA7.6.2.4(b)) E- c. The correct time and date are properly set in the time switch. (NA7.6.2.4(c)) E` d. The battery backup (if applicable) is installed and energized. (NA7.6,2.4(d), §110.9(b)1) E` e. Override time limit is no more than 2 hours. (NA7.6.2.4(e), §110.9(b)lAi, §130.1(c)3B) OR The automatic time switch control's override time is exempt from the 2 -hour limit. (EXCEPTION to §130.1(c)3B) F f. Override switches remote from area with controlled luminaires have annunciator lights. (NA7.6.2.4(f), §130.1(c)3A, §130.1(x)) OR The manual override switch is exempt from being in the same enclosed area with the lighting it controls. (EXCEPTION 1 to §1.30A (a)2) Construction Inspection Compliance: (: Complies E Does Not Comply NA cAp1 (/\� California Advanced Lighting LVTI Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance 'Phis is page I of 5 OFACCEPTANCE B -l. Automatic Time Switch Lighting Control Functional Testing (NA7.6.2.5) Confirm compliance (Y - yes / N - no) for the control being tested. NA California Advanced Lighting cALGTP Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 2 of 5 A-2. Occupant Sensing Lighting Control Construction Inspection (NA7.6.2.2)) r a. Occupant sensors have been located to minimize false signals, (NA7.6.2.2(a)) 7 6. Occupant sensors are located no closer than four (4) feet from any HVAC diffuser, (NA7.6.2.2(b)) 17 c. Passive infrared sensor pattern does not enter into adjacent zones. (NA7,6,2.2(c)) r d. Occupant sensors do riot encounter any obstructions that could adversely affect desired performance. (NA7.6.2.2(d)) W e. Ultrasonic occupant sensors do not emit audible sound. (NA7.6.2.2(e), §110.9(b)6Bii) Construction Inspection Compliance: <• Complies r Does Not Comply B-2. Occupant Sensing Lighting Control Functional Testing (NA7.6.2.3) Confirm compliance (Y - yes / N - no) for the control being tested. Building: 450 Newport Center Di Floor: 2 Ste 220 Room: Office Control: Occupancy WV Control is representative of sample. (NA7.6.2.3) If sampling method is used, attach a page listing untested controls in sample. Step 1: Simulate an unoccupied condition. (NA7.6.2.3(a)) r a. Lights controlled by occupant sensing control turn off or partially off, if applicable, within a maximum of 20 minutes from start of an unoccupied condition. (NA7.6.2.3(a)1, §110.9(b)4A) In the partial off state, partial -OFF occupant sensors automatically reduce lighting power by at least 50% (§130.1(c)6A-C, §130.1.(c)7A), OR: • For metal halide or high pressure sodium lighting in warehouses, automatically reduce lighting power by at least 400/0 (EXCEPTION 2 to §130.1(c)6A), • In aisle ways and open areas in warehouses in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION 1 to §130.1(c)6A). • in corridors and stairwells in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least. 40% (EXCEPTION to §130.1(c.)7A). Occupant sensing controls in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 50% of design lighting power (§130.1(c)7B), OR Occupant sensing controls for metal halide luminaires with a lamp Plus ballast mean system efficacy of 75 lumens per watt in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 60% of design lighting power (EXCEPTION to §130.1(c)7B). r b. The occupant sensing control does not trigger a false "on" from movement in an area adjacent to the controlled space or from FIVAC operation. (NA7,6.2.3(a)2) r c. Signal sensitivity is adequate to achieve desired control. (NA7.6.2.3(a)3) For library book stacks or warehouse aisles, activity beyond the stack or aisle shall not activate the lighting in the stack or aisle. (§130.1(c)6A, §130.1(c)6B) Step 2: Simulate an occupied condition. (NA7,6.2.3(b)) a. Status indicator or annunciator operates correctly. y. (NA7.6.2.3(b)1, §1109(b)4C) WV b. Immetliately upon an occupied condition (NA7.6.2.3(b)2): • Lights controlled by an occupant sensor or a partial -OFF occupant sensor turn on; OR: • A vacancy sensor indicates a space is "occupied" and lights may be turned on manually; OR: • The first stage of a partial -ON occupant sensor automatically activates between 50 to 70% of the lighting. (§ 130.1(c) SA) OR: After the first stage occurs for partial -ON occupant sensors, manual switches allow an occupant to activate the alternate set of lights, activate 100% of the lighting power, and manually deactivate all of the lights, Functional Testing Compliance: C i L �p California Advanced Lighting Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 3 of 5 TE OF ACCEPTANCE [NYrtYNiY01:15/tA]:YY (- Complies f Does Not Comply CAY (/��� j'j� California AiNanced Llghting LGT Controls Training Program. CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 4 of 5 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT f certify that this CeI tifiraCe of Acceptance door ire oration is accurate and complete, Documentation Author Company Name Name Idatthew Kirchwehm Address City/State/Zip 45225 Tioga St Phone CEA/A'rT Certification (058)568-6793 Identification (if applicable) Author Signature Date of Signature: 05/14/2022 1st Advanced Energy Consultants Temecula, CA 92592 TC -A813924 FIELD TECHNICIAN'S DECLARATION STATEMENT I certify the fallowing under penalty of perjury, under the laws of the State of California: 1. The information at on this Cert ifi<ate of Acceptance is true and carrect. 2. I am the person who performed the acceptance verification reported on this Certificate of Acceptance (Field Technician). 3. The construction or in stallatlon identified on this Certificate of Acceptance complies with the applicable acceptance requirements Indicated In the plans and specifications approved by the enforcement agency, and conforms to the applicable acceptance requirements and procedures specifir-d in Reference Nonresidential Appendix NA]. 4. I have confirmed that the Certificate(s) of Installation for the construction or installation identified on this Certificate of Acceptance has been completed and signed by the responsible builder/Installer and ha!: been posted or made avallable with the building paranoia) issued for the building. Field Technician Name Company Name Matthew Kirchwehm 15[ Advanced Energy Consultants Address: 45225 Tioga St CiLy/Sta Le/Zip Temecula, CA 92592 Phone ALL Certification (8.58)568-6793 Identification TC -A813924 Position with Company Field Technician Signature (Tide) Owner Data of Signature��Frt 05/14/2022 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: I. I am the Field Technician, or the Field Technician is acting on my behalf as my employee- or my agent and I have reviewed the information provided on this Con Lfi ca to of Acceptance. 2. 1 am eligible under Division 3 of the business and Professions Code in the applicable classification to accept responsibility for the system design, construction or installation of features, materials, components, or Manufactured devices for the scope of work identified on this Certificate of Acceptance and attest to the declarations in this statement (responsible acceptance person). 3. The infoi matlon provided on this Certificate of Acceptance substantiates that the construction or installation Identified on this Certificate of Acceptance complies with the acceptance requirements indicated in the plans and specifications approver) by the enforcement agency, and conforms to the applicable acceptance requirements and procedures specified in Reference Nonresidential Appendix NA], 4. I have confirmed that the Certhicate(s) of Installation for the construction or installation identified on this Certificate of Acceptance has been completed and is posted or made available with the building permit(s) issued for the building. 5. I will ensure that a completed, signed copy of this Certificate of Acceptance shall be posted, or made available with the building permits) Issued for the building, and made available to the enforcen'ient agency for all applicable Inspections. f understand that a signed copy of this Certificate of Acceptance is required to be included with the docwnentation the builder provides to the building owner at occupancy. Acceptance Company Name Responsible Matthew Kirchwehm list Advanced Energy Con school s Person Responsible 9Y Address: 45225 1 tape St City/ State/Zip Temecula, CA 92592 Phone CSLB License (856)568-6793 TC -A813924 Position with Company Responsible Acceptance Person Signatorc (Title) ^Owner ` Date of Signature: 05/14/2022 CAY�'/�\`r�rC, California Advanced Lighting IN I I— Controls Training Program CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 5 0( 5