CASE NO.: 2022-099
❑ REQUEST FOR MODIFICATION TO PROVISIONS
OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE)
OF THE NEWPORT BEACH MUNICIPAL CODE
(See Reverse for Basis for Approval) (Fee $291)
REQUEST FOR ALTERNATE MATERIAL
OR METHOD OF CONSTRUCTION
(See Reverse for Basis for Approval) (Fee $291)
For above requests, complete Sections 1, 2 & 3
below by printing in ink or typing.
JOB ADDRESS:
SITE ADDRESS: 1660 Dove Street
Owner Aryabhata Group LLC
Address 520 Newport Center Drive, Suite 480
Newport Beach Zip 92660
Daytime Phone (
) 440-666-5779
FOR STAFF USE ONLY
Plan Check # 1 ,w `1-0 # of Stories lro 5
Occupancy Classification R-2'Q7�F��
Use of Building NF V-h3A(uf-t 6 # of Units 3e
Project Status C'_+4FGfe-
Construction Type
Verified by MIS
No. of Items
Fee due )
DISTRIBUTION:
❑ Owner Plan Check )11�
®, Petitioner ❑ Inspector
❑ Fire ❑ Other
PETITIONER:
Petitioner AO (Kara Sutch)
(Petitioner to be architect or engineer)
Address 144 N. Orange Street
Orange
Daytime Phone ( ) 714-639-9860
Email:, karas@aoarchitects.com
Zip 92866
"2 REQUEST: Submit plans if necessary to illustrate request. Additional sheets or data maybe attached. iI
To provide a 2 hour smoke and fire rated roll down curtain in lieu of a Fire Barrier Wall as required per California Building Code sections
1024.3 and 707, US Smoke and Fire, Dual Hose Stream 120. This curtain occurs between the exit passageway on the first floor and the exit
access corridor on the second floor.
TION/FINDINGS OF EQUIVALENCY: CODE
707.7.1
The 2 hour smoke and fire rated roll down curtain will be tied to the fire alarm and fire
suppression systems to automatically close in the event of an emergency. Standby
Emergency Power wil I be provided per CEC Article 700.12. The proposed roll down
curtain will provide the required 2 hour wall rating and will provide equivalent Fire Barrier
We I I protection at the opening during afire. See attached letter.
Position Principal
Petitioner's Kara Sutch 02-06-23
Signature CA Professional Lic. # Steven Gaffney Date:
FOR STAFF USE ONLY
DEPARTMENT ACTION: In accordance with: 2fCBC 104.11/CFC 104.9
(Alternate materials & methods)
❑ CBC 104.10/CFC 104.6
(CBC Modification)
❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved
❑ Written Comments Attached
\ l in Date
.Request (DOES) OES NOT lessen any fire protection requirements.
-Request (DOES) OES NOT�Iessen the structural integrity
The Request is: ,[ Granted ❑ Denied (See reverse for appeal information)
❑ Granted (Ratification required)
Conditions of Approval:
Signature — `— t - Position CMFF 8U!LD;VG OFFICIAL
Date OZ- Dic- ?.O23
Print Name l fir`/ct= I tii-yYS
APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse)
(Signature, statement of owner or applicant, statement of reasons for appeal and filing fees are required.)
CASHIER RECEIPT NUMBER: 1""d -00o0,433 Forms\modif 07/01/21
144 N. Orange Street, Orange, CA 92866 T 714.639.9860 aoarchitects.com
February 6, 2023
City of Newport Beach
Community Development Department
100 Civic Center Drive
Newport Beach, CA 92660
Melissa Kubischta, SE
Civil Engineer- Plan Check
Re: Plan Check Number2117-2020
Newport Crossing Apartments
1660 Dove Street
Newport Beach, CA 92658
Melissa,
AO Architecture.
Design.
Relationships.
As permitted in CBC 104.11, the purpose of this letter is to request the use of an alternative material, design and method of
construction for the two-story corridor openings on the project.
ub'ect:
Per 712.1.9, two-story openings are permitted under certain conditions. The project has an R-2 corridor with a storefront lobby
area. The preferred design is to create a two-story volume space at the first to second level along the corridor to allow more
natural light and view to the exterior.
Discussion:
A fire rated curtain is proposed in order to provide the required rating and close the opening between the two-story areas.
• Per 707.6, openings in a fire barrier for an exit passageway are only as permitted by 1024.5.
o Section 1024.5 requires that openings in an exit passageway be limited to those necessary for exit access.
Therefore, the opening in the two-story volume space will provide the equivalency of a fire barrier wall.
• Per 707.7.1, penetrations into a fire barrier for an exit passageway are only as permitted by 1024.6.
• Per 703.2 fire -resistance assemblies are to be rated as determined by the testing procedures in ASTM E119 or UL 263.
o The Dual Hose Stream 120 fire curtain is ASTM E119 listed and labeled for 2 hour.
• The area where the fire curtain occurs will normally be open.
o The fire curtain has an automatic closing feature.
o The fire curtain will close upon fire alarm and or fire sprinkler activation.
Conclusion:
In our opinion, the use of a fire curtain such as the Dual Hose Stream 120 or equal meets and exceeds the opening protection
requirements for the two-story opening that requires a fire barrier wall.
Thank you for your consideration. Please feel free to contact AO with any further questions.
Kara Sutch I Principal
karas2aoarchitects. com
Page 1 of 1
a
mA_Ls 33S t jn_Lon8_Ls
IWS13S .b4 1 ief JtWSl3'
a
01 M�II* o �•�
0
m
5TH LEVEL.
4TH L
3RD LEV
rm
T.O. PLATE
T.O. SHEATHING
c
T.O. PLATE
1-HR 3
Fourth story corridor
open to the third
story corridor
5
T.O. SHEATHING I -H& 01.1
Proposed fire curtain r�
om
LN T.O. SHEATHING
T.O. PLATE
Second story corridor
open to the first story
6' corridor
b
1ST LEVEL
T.O. SLAB
(39.30)
2 Hour Curtain
16
11.1. 1-HR
1
11.1. 1-HR
13 1'
11.2.2 A01.1.2 1-HR
1 Wo
2-HOUR EXIT
PASSAGEWAY #4
14
y �
p DUAL HOSE STREAM 1200 www.ussmokeandfire.com
p y ri 1 U.S. SMOKE & RRE® 2 HOUR STEEL- FIRE SHUTTER www.ussmokeandfirecurtain.com
41), 888.917.8777
The DUAL HOSE STREAM 120' is a deployable Steel -Tex
fire shutter system composed of wired reinforced Steel -Tex
fire shutter on round steel tubes In a fire rated assembly.
The Steel -Tex fire shutters remain retracted above the
finished telling until activated by fire alarm or smoke alarm
at which point hey descend at 9 in/sec. and create a smoke
and fire barrier. The shutter can also be non -motorized
when activated by a fusible link for smaller openings.
The system consists of:
• A roller assembly with a 0.05 in, thick galvanized steel
Two independent head boxes side by side with a
minimum 9 in. x 9 in. dimension. Maximum span up
to 146 ft. and drop height of 40 ft.
A motor controller (MC) is housed in a steel
enclosure and mounted onto the motor end of the
head box. NFPA 70 compliant DC motor interfaced with
Control Panel (CP) and a suitably weighted bottom bar.
Internal or external motor depending on length.
Removable fire rated cover plates incorporated to allow
access to shutter roller.
• Shutter passes through fire rated galvanized steel
auxiliary rails (side guides) that are factory painted or
can be repainted in the field by others.
• If required, egress switches can be provided on both
sides of shutter when shutter Is directly in the path
of egress.
• Tested at Guardian Fire Testing Laboratories.
Accreditation
ISO 17025 (testing)
ISO 17020 (Inspection)
ISO 17065 (production certification)
• Tested at Intertek
The DUAL HOSE STREAM 120' is certified for quality by
ISO 9000, meets and exceeds the requirements of:
• Each Hose Stream headbox is tested listed and
labeled in accordance to UL 1 OB and ASTM E2226
(Hose Stream Test) for 90 minutes each
• Harmathy Principle -Two hose stream 120® systems
installed back to back summates the rating per
IBC 715 thus 180 minutes to UL 10B
• ASTM El19 (UL263) is listed and labeled assembly
for two hours in accordance with IBC 903.3.1.1
• NFPA 105 and NFPA 252 Compliance
• Tested toUL17841ntertekto.lwater column
with no artificial bottom seal
T
• UL864listed and labeled Releasing Device
• UL 864listed and labeled Canada Releasing
• Bottom bars deploy --9"/second
• Failsafebattery backup
• Building Management System Relay option
• Leading Edge Safety Sensor option
• Surface Membrane Retract Switch option
CONTROL PANEL (CP):
The shutter deployment mechanism is directly synced and integrated in the fire alarm emergency systems.
When an alarm signal is detected, the Control Panel (CP) will automatically trigger the shutter systems to deploy in a controlled
descent under gravity. In normal operating conditions the CP provides AC supply to the Motor Controller (MC) to keep the
shutters in retracted condition. Should smoke he detected, the fire alarm control system will send a signal to the CP and the
shutters will deploy at a controlled speed to their operational position. When the fire alarm system goes back to normal power
mode, the shutters will automatically retract hack to the housing.
DUAL HOSE STREAM SHUTTER DIAGRAM 1
SIDE GUIDES TO EXTEND
INTOHEADBOX
STEEL TEX FIRE SHUTTER RETAINING
MECHANISM IS FVLLY
ENCLOSED WITHIN S10E GUIDES
SIDE GUIDE PLACED OVER
SNUORT BRACKET.
BRACKET BOLTS TO FLOOR.
ALI Neu I u ervu /W u nenrc re�.eo ar
HEADBOX
0111 U.S. SMOKE & FIRE®
12310 Pinecrest Road, Suite 300, Reston, VA 20191 • Phone: 888.917.8777 • Fax: 888.917.8777
Washington, DC • Boston • New York • Miami • Dallas • San Francisco
www.ussmokeandfire.com • aeteam@ussmokeandfire.com
In emotional
n
ANSI
1
1 Organization for
9
Ati!_
NFj1A'
n,lsmme.e,.ncn
SYandardizanon
City of Newport Beach
o� COMMUNITY DEVELOPMENT DEPT Credit Card
] 00 Civic Center Dr.
= Newport Beach, CA 92660
Authorization Form
949-718-1888
Authorized by:
Use this form to authorize credit card payment for the City of Newport Beach,
Community Development Department
ACCOUNT NUMBER (if applicable):
Reason for payment: 900 SPRING TIDE DR NEWPORT BEACH, CA 92660
Authorized amount to be charged: $ 210
PLEASE PRINT
Name (as it appears on card)
Email
CAMILLE ADECER
camille.adecer@sunpowercorp.com
Billing Address for Card
4117 Novella Cove
City
State
Zip Code
Telephone Number
Fax #
Leander
TX
78641
5102608384
Authorized Cardholder Signature
Date
C- {O t71
02/06/2023
❑ VISA O MASTERCARD ❑ AMERICAN EXPRESS ❑ DISCOVER I
ACCOUNT NUMBER:
❑5AA9❑ RIA0161 Q1[ A® AA9❑®
EXPIRATION DATE: CVC Code:
[0 4] / 2F5
For more information, please call 949-718-1888