HomeMy WebLinkAboutX2021-1680 - Alternative Material & Methods (4),(2021-16YO CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 I Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 CASE NO.: 2022-098 REQUEST FOR MODIFICATION TO PROVISIONS OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE) OF THE NEWPORT BEACH MUNICIPAL CODE (See Reverse for Basis for Approval) (Fee $291) REQUEST FOR ALTERNATE MATERIAL OR METHOD OF CONSTRUCTION (See Reverse for Basis for Approval) (Fee $291) III FOR STAFF USE ONLY III Plan Check# 21 0 #.ofStories 5 Occupancy Classification R.2 A 5 Use of Building of Units 3 So Project Status Pt..c�N GttEu� Construction Type l T` A - i - Verified by 1-1�\z- No. of Items (. Fee due For above requests, complete Sections 1, 2 & 3 DISTRIBUTION: below by printing in ink or typing. ❑ Owner Ian Check M� 0 Petitioner Inspector ❑ Fire ❑ Other JOB ADDRESS: PETITIONER: SITE ADDRESS: 1660 Dove Street Petitioner AO (Kara Sutch) Owner Ary abhata Group LLC (Petitioner to be architect or engineer) _ Address . 520 Newport Center Drive, Suite 480 Address 144 N. Orange Street Orange Zip 92866 Newport Beach Zip 92660 Daytime Phone ( ) 714-639-9860 - Daytime Phone ( ) 440-666-5779 Email:, karas@aoarchitects.com 2 REQUEST: Submit plans if necessary to illustrate request. Additional sheets or data may be attached. To provide a 1 hours moke and fire rated roll down curtain in lieu of opening protectives as required per California Building Code sections 708.6 and 716, Door Systems model IDS I-CiHR (Cl HRS). This curtain occurs where the exit access corridors are open between the third and fourth floors in the R-2 occupancy. GS OF EQUIVALENCY: CODE SECTIONS: 708, 712.1.9 The 1 hour smoke and fire rated roll down curtain will be tied to the fire alarm and fire suppression systems to automatically close in the event of an emergency. Standby Emergency Power will be provided per CEC Article 700.12. The proposed roll down when closed will provide more than the 20 minute opening protection rating listed in CBC Table 716.1(2) and will exceed equivalent protection at the opening during a fire. See attached letter. Petitioner's Kara Sutch Signature Position Principal CA Professional Lic. # Steven Gaffney 19676 02-06-23 FOR STAFF USE ONLY DEPARTMENT ACTION: In accordance with: /KCBC 104.11/CFC 104.9 (Alternate materials & methods) ❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved By: Date E Request (DOES) ( OES NOT) assen any fire protection requirements. [!rRequest (DOES) (KO -ES NOT� lessen the structural integrity ❑ CBC 104.10/CFC 104.8 (CBC Modification) ❑ Written Comments Attached The Request is: Granted ❑ Denied (See reverse for appeal information) ❑ Granted (Ratification required) Conditions of Approval: CHIEF BUILDING OFFICIAL Sigre natu—1 _ - Position Print Name f�-.-.r�s= 1 Hoer Date DZ-Pro - APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse) (Signature, statement of owner or applicant, statement of reasons for appeal and filing fees are required.) CASHIER RECEIPT NUMBER: I )y -'C oc7c4)3 3 Forms\modif 07/01/21 Architecture. Design, 144 N. Orange Street, Orange, CA 92866 T 714.639.9860 aoarchitects.com AO Relationships. February 6, 2023 City of Newport Beach Community Development Department 100 Civic Center Drive Newport Beach, CA 92660 Melissa Kubischta, SE Civil Engineer - Plan Check Re: Plan Check Number2117-2020 Newport Crossing Apartments 1660 Dove Street Newport Beach, CA 92658 Melissa, As permitted in CBC 104.11, the purpose of this letter is to request the use of an alternative material, design and method of construction for the two-story corridor openings on the project. ub'ect: Per 712.1.9, two-story openings are permitted under certain conditions. The project has an R-2 corridor with a storefront lobby area. The preferred design is to create a two-story volume space at the third to fourth level along the corridor to allow more natural light and view to the exterior. Discussion: A fire rated curtain is proposed in order to provide the required rating and close the opening between the two-story areas. • Section 708.6 states that openings in a fire partition are to be protected in accordance with 716. • Per Table 716.1(2) the opening protection would be required to be 20 minutes with a D-20 label or 20 minute rated. o A fire curtain will provide the rating with the required label. • Table 716.1(1) requires that this label complies with NFPA 252 or UL 10B or UL 10C. o The CiHRS fire curtain is compliant with UL 10B and IOC. o The C1HRS fire curtain is listed with Cal Fire under listing number 4077-2312:0501. • The area where the fire curtain occurs will normally be open. o The fire curtain has an automatic closing feature. o The fire curtain will close upon fire alarm and or fire sprinkler activation. Conclusion: In our opinion, the use of a fire curtain such as the DSI-ClHR (C1HRS) or equal meets and exceeds the opening protection requirements for the two-story opening. Thank you for your consideration. Please feel free to contact AO with any further questions. Kara Sutch I Principal karasCaaaoarchitects com Page 1 of 1 O 0 II I x N � � M � Z a a li i aN — minlonais 3as vanlonaus 33 1NIOf 0IWS13S 1or oIWSI�S � a �V6 1 I � do In � fl NO O U p p � c � p N @ O p 2 5TH 4TH 3RD c� 2ND LEVEL, 0 1ST LEVEL T.O. SLAB (39.30) T.O. PLATE 11 Hour Curtain I 3 Fourth story corridor open to the third story corridor T.O. SHEATHING 1-H D1.1 I.O. FLA I L Proposed fire curtain 13 2-HR AD1.2 T.O. SHEATHING T.O. PLATE 2-HR 3 Second story corridor open to the first story corridor 5 2-HOUR EXIT PASSAGEWAY #4 L1 1.1. 1-HR 16 i1.1. 1-HR 16 l.1 1-HR 16 1.1. 1-HR 14 11.2 MODEL DSI-Cl HR Smoke and Fire Curtain The DSI Smoke and Fire Curtain Model DSI-CIHRSS single barrel configuration for widths under 16 feet and Model DSI- CIHRSM multi barrel configurations for widths over 16 feet create a one hour opening protective smoke and fire barrier. The assembly comprises a fire -rated fiberglass fabric wrapped around a roller which encases a compact head box that is typically installed above the ceiling with side guides that are buried in the wall. This makes the system virtually invisible until activated. The DSI-CIHR Smoke and Fire Curtain is totally Gravity Fail Safe, resets automatically, and incorporates the latest in electronic technology. As a result, DSI-C1HR Curtain is one of the most advanced, yet cost effective systems on the market. Compliant with... Code Description UL 10 D C1 HR. Fire protective Smoke Curtains —60 minutes UL 1784 Air leakage test of door assemblies UL 10 C Without Hose Stream Test— 20 minutes UL 10 B Without Hose Stream —20 minutes UL 864 Control Units for Fire Protective. Signaling Systems California State Fire Marshall Listed OSHPD LAFD Approval for High Rise Applications DATA CUT SHEET ADVANTAGES: Cost-effective • Creates open space for your building design • Compact design, low headroom requirements • Virtually invisible design • Lightweight, requires little to no structural support • Unlimited width, custom sizes • Code compliant • Multiple egress options • Battery backup system standard • Fail safe system with automatic reset GUARANTEED QUALITY Door Systems guarantee high quality products, tested Is both UL and BS standards. MODEL DSI-ClHR Smoke and Fire Curtain HEADBOX FINISHING OPTIONS Flush to Ceiling (OPTION#1) SIDE GUIDE MOUNTING OPTIONS Exposed Flush (SGMEF) SINGLE ROLLER MOUNTING OPTIONS Fixed Mount (SRMFM) Fixed directly to the lintel above an opening. MULTIPLE ROLLER MOUNTING OPTIONS Exposed Mount (OPTION#2) Butt to Wall Flush (SGMBWF) Soffit Fixed Mount (SRMSFM) Fixed directly to the underside of the soffit slab. I� Shadow Gap (OPTION#3) Inset in Wall Flush (SGMIWF) 179 Suspended Soffit Mount (SRMSSM) Suspend from soffit via unistruts and all thread. Over/Under Arrangement (MRMOU) Side by Side Arrangement (MRMSS) Suspended Over/Under Arrangement Fixed directly to the lintel above an opening. Fixed directly to the underside of the soffit slab. (MRMSOU) Suspend from soffit via unistruts and all thread. CERTIFICATE OF COMPLIANCE Certificate Number 20220406-R39636 Report Reference R38702 Issue Date 2022-April 06 Issued to: Door Systems Inc 1150 Las Brisas PI Placentia, CA 92870 USA This certificate confirms that Fire -protective Curtains representative samples of Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 10D, "Fire Tests of Fire Protective Curtain Assemblies." UL 1784, "Air Leakage Tests of Door Assemblies." Additional Information: See the UL Online Certifications Directory at hops://ig.ulprospector.com for additional information. This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow -Up Services Procedure provides authorization to apply the UL Mark. Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL's Follow -Up Services. Look for the UL Certification Mark on the product. See addendum pages 2-3. Bruce MaM1nnM1OI; Clrector North American Cetllfiolion Program UL LLC Any Infarmation and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authoduad licensee of UL. For questions, please contact a local UL Customer Service Rproomeallve atb 'ill M el (ED Page 1 of 4 CERTIFICATE OF COMPLIANCE Certificate Number Report Reference Issue Date 20220406-1339636 R38702 2022-April 06 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Model(s) below are for use in gypsum or masonry wall type constructions, maximum 3657 mm (144 in.) wide by 3048 mm (120 in.) high. When greater than 3657 mm (144 in.) wide by 3048 mm (120 in.) high, the single barrel and multibarrel assemblies are eligible for the Oversized Label and may be produced up to 6 m (19.7 ft.) wide by 12 m (39.4 ft.) high and up to 300 m (984.3 ft.) wide by 12 m (39.4 ft.) high, respectively. Fire -protective curtain: DSI-C1HRS Smoke and Fire Curtain, 1 hr fire rating. DSI-600S1 Elevator Smoke Containment System, 1 hr fire rating DSI-C1 HRM Smoke and Fire Curtain, 1 hr fire rating. DSI-600M1 Elevator Smoke Containment System, 1 hr fire rating. DSI-C3HRS Smoke and Fire Curtain, 3 hr fire rating. DSI-600S3 Elevator Smoke Containment System, 3 hr fire rating. DSI-C3HRM Smoke and Fire Curtain, 3 hr fire rating. DSI-600M3 Elevator Smoke Containment System, 3 hr fire rating. DSI-D1 HRS Automatic Smoke Draft Curtain, 1 hr fire rating. DSI-D1 HRM Automatic Smoke Draft Curtain, 1 hr fire rating. DSI-D3HRS Automatic Draft Curtain, 3 hr fire rating. DSI-D3HRM Automatic Draft Curtain, 3 hr fire rating. Model(s) above may have suffix "E" for egress option. Bruce Mahronh iz. Olrector North American Comficatlon Program UL LLC Any Information and documentation Involving UL Mark sarvlwa are provided on behalf of UL LLC ryy or any authorized Ilcansee of UL For pu ralimm, please contact a local UL Customer Service Representative at hUp1lutucombabourufflocafimed Page 2 of 4 CERTIFICATE OF COMPLIANCE Certificate Number Report Reference Issue Date 20220406-R39636 R38702 2022-April 06 Model(s) below are for use in masonry or gypsum wall type constructions, maximum 3657 mm (144 in.) length by 3048 mm (120 in.) high. When greater than 3657 mm (144 in.) length by 3048 mm (120 in.) high, the assembly is eligible for the Oversized Label and may be produced up to 250 m (820.2 ft.) length by 12 m (39.4 ft.) high. Fire protective curtain: DSI-A1HR Accordion Smoke and Fire Curtain, 1 hr fire rating. DSI-A4HR Accordion Smoke and Fire Curtain, 4 hr fire rating. Model(s) below are for use in masonry floor type constructions, maximum 10000 mm (394 in.) travel by 8000 mm (315 in.) wide and maximum 8000 mm (315 in.) travel by 10000 mm (394 in.) wide. Fire protective curtain: DSI-H1HR Horizontal Fire Curtain, 1 hr fire rating DSI-H3HR Horizontal Fire Curtain, 3 hr fire rating DSI-H1HR Horizontal Fire Curtain, 1 hr fire rating Oversized. DSI-H3HR Horizontal Fire Curtain, 3 hr fire rating Oversized. The products below have been additionally investigated to ANSI/UL 1784 Fire -protective curtain: DSI-CIHRSS Smoke and Fire Curtain, 1hr fire rating DSI-CIHRSM Smoke and Fire Curtain, 1hr fire rating DSI-C3HRS5 Smoke and Fire Curtain, 3hr fire rating DSI-C3HRSM Smoke and Fire Curtain, 3hr fire rating DSI-DIHRSS Automatic Draft Curtain DSI-DIHRSM Automatic Draft Curtain DSI-D3HRSS Automatic Draft Curtain DSI-D3HRSM Automatic Draft Curtain Bruce Mmunholz, vector Nodb American Certification program U UL LLL Any Information and documentation Involving UL Mark se r sme provided on behalf of UL LLC JUL) or any authorized licensee of UL. For quotation., please contact a local UL Cusmmer SeMco RapreaentatWe at M I Page 3 of 4 CERTIFICATE OF COMPLIANCE Certificate Number Report Reference Issue Date 20220406-R39636 R38702 2022-April 06 DSI-A4HR Accordion Smoke and Fire Curtain, 4 hr fire rating DSI-A1HR Accordion Smoke and Fire Curtain, 1 hr fire rating DSI 600S1 Elevator Smoke Containment System, 1hr fire rating DSI 600M1 Elevator Smoke Containment System, 1hr fire rating DSI 600S3 Elevator Smoke Containment System, 3hr fire rating DSI 600M3 Elevator Smoke Containment System, 3hr fire rating Bruce Matirennuz, Director Monb American certification Program UL LLC Any Information and documentation involving UL Mark aervlwe are provided an behalf of UL LLC (UL) or any autMrizetl licensee of UL. For questions, please contact a local UL Customer Service Representative at bits fu coMabartufamcationel EO Page 4 of 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 4077-2312:0501 Page 1 of 2 CATEGORY: 4077 -- FIRE PROTECTIVE CURTAIN LISTEE: Door Systems, Inc.1150 Las Brisas Place, Placentia, CA 92870 Contact: Jeff Bonnema (714) 222-3769 Fax (714) 258-7171 Email: jeff@doorsysinc.com DESIGN: Models C1HRS, C1HRM, C3HRS, C3HRM, D1HRS, D1HRM, D3HRS, D3HRM, DSI-600S1, DSI-600M1, DSI-600S3, and DSI-600M3 fire -protective smoke curtains consist of a woven glass fiber, silver polyurethane coated fabric attached to rollers contained within a surface or between -jamb mounted steel curtain box. The curtain shall overlap a minimum 19.7 in. for multiple barrel assemblies. The maximum opening size is 236.2 in. wide by 472.4 in. high for single barrel assemblies and 1417.3 in. wide by 472.4 in. high for multiple barrel assemblies. Models A1HR and A4HR fire -protective smoke curtains consist of a woven glass fiber, silver polyurethane coated fabric contained within a surface or between -jamb mounted steel ceiling tray. The opening type is a single barrel accordion, using Dunkermotoren GMBH motors (Models GR53x30 and GR42x40) installed at the header and barrel assembly. The maximum opening size is 236.2 in. wide by 472.4 in. high for single barrel assemblies and 1417.3 in. wide by 472.4 in. high for multiple barrel assemblies. Refer to listee's data sheet for additional product description and operational considerations. RATING: UL 10D: Models C1HRS, C1HRM, D1HRS, D1HRM, DSI-600SI, DSI-600M1 - 1 hr classification Models C3HRS, C3HRM, MRS, D3HRM, DSI-600S3, DSI-600M3 - 3 hr classification Model Al HR - 1 hr classification Model A4HR - 3 hr classification for gypsum wall type construction, 4 hr classification for masonry wall type construction UL 1784: Models DSI-600 ELEVIS, DSI-600 ELEVIM, DSI-600 ELEV3S, DSI-600 ELEV3M: 1,57 CFM/FT' ambient; 0.47 CFM/FT' 400°F; 0.05" water column 2.31 CFM/FT' ambient; 0.79 CFM/FT' 400"F; 0.10" water column 5.28 CFM/FT' ambient; 2.91 CFM/FT' 400°F; 0.20" water column 14.00 CFM/FT' ambient; 0.30" water column INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, and UL label. APPROVAL: Listed as fire -protective smoke curtains for use in gypsum or masonry wall type 04-06-20 V W W This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not 'v an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO„ M.E., F.P.E. Fire Engineering Division Listing No. 4077-2312:0501 Page 2 of 2 constructions. For use where allowed by the California Building Code and the authority having jurisdiction. Refer to listee's Installation Instruction Manual for details. NOTE: This item is for nonstructural applications and NO hose stream tests were conducted. XLF: 4077-2311:0501 04-06-20 V W W This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not 0an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO„ M.E., F.P.E. Fire Engineering Division