Loading...
HomeMy WebLinkAboutPA2022-0315_20230426_Residential Zoning Corrections Residential Zoning Corrections Community Development Department Planning Division 100 Civic Center Drive; P.O. Box 1768 Newport Beach, CA 92658 949-644-3200 www.newportbeachca.gov Plan Check No.: PC2022-3232 Address: 2741 Ocean Blvd Date: 04/26/2023 Corrections Required Contact Information “1” (First Review): 02/13/23 “2” (Second Review): 04/26/23 “3” (Third Review): If you have questions regarding your plan check, please contact: Plan Checker: David Lee Email/Phone: dlee@newportbeachca.gov - 949-644-3225 Please contact me to discuss corrections prior to resubmitting. GENERAL INFORMATION 1. Zone: R-1 Setback Map No: S-10B PC Text: 2. Proposal: New Addition Alteration Other 50% ADD/ALT 3. No. of Units Allowed: 1 No. of Units Proposed: 1 4. Demo Proposed Yes No If Yes, number of units to be demolished COASTAL COMMISSION REVIEW 5. Coastal Zone: Yes Exclusion Zone No 6. Exempt because: 7. Categorical Exclusion No.: Effective Date: 8. Waiver No: Effective Date: 9. AIC No: Coastal Development Permit No: PA2022-0315 Effective Date: 10. FYI Coastal Approval Letter (all pages) to be scanned into plans. 11. FYI Comments: >10% ADDITION, DOES NOT QUALIFY FOR CEO DUE TO SUBSTANTIAL CONFORMANCE WITH EXISTING VARIANCE AND SIZE OF ADD, PENDING EFFECTIVE DATE OF CDP DISCRETIONARY ACTION 12. Application required: Reason: 13. FYI Previous Discretionary Approvals: 1. Application Type MODIFICATION PERMIT No. For: SITE WALLS AND IMPROVEMENTS IN THE 10-FT FRONT SETBACK OVER 42 INCHES IN HEIGHT. 2. Application Type COASTAL DEVELOPMENT PERMIT No. For: ADD/ALT THAT DO NOT QUALIFY FOR CEO 3. Application Type STAFF APPROVAL No. For: SUBSTANTIAL CONFORMANCE TO PREVIOUSLY APPROVED VARIANCE 4. Application Type No. For: 5. Application Type No. For: 14. Please make an appt with: Phone: Email: 15. 2 Scan approval letter / resolution (including conditions) into plan sets. Copy attached 16. HOLD ON FINAL. The following items must be completed before the building permits are finaled: Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\Admin\Energov\PLNG PC2022-3232 CO DL 2023-04-26.docx (pw_CDD) Page 2 of 11 17. 2 Comments: MKN COMMENT 2/14/23: Consider modifying the project design to 1) remove the wall/planter areas adjacent to Way Lane, 2) remove the new chimney that projects above the top of curb elevation, and 3) reduce the entry wall/stair to the minimim size and height necessary to comply with the Building Code. DL COMMENT 4/26/23: 1)It has been determined that the existing encroaching wall on Way Lane may remain, 2)Chimneys have been removed from proposed plans, 3) See red marked plans regarding which portions of entry walls may remain. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\Admin\Energov\PLNG PC2022-3232 CO DL 2023-04-26.docx (pw_CDD) Page 3 of 11 REQUIRED FEES 18. Fairshare Fee Contribution: 19. San Joaquin Hills Transportation Corridor Fee: 20. Other: LOT OR PARCEL STATUS 21. Legal Description: Lot: PCL B Block: 033 Section: Tract: CDM, RECORD OF SURVEY 2015-1098 22. Easement(s) on-site: Yes No Verify with Public Works 23. No person shall develop any structure including, but not limited to, a principal or accessory structure across a lot line per Section 19.04.035 (Development Across Property Lines) of the Subdivision Code. Please apply for a Parcel Map, Lot Merger, Lot Line Adjustment, or Certificate of Compliance to address underlying legal lot lines. 24. Comments: SETBACKS 25. Setback Regulations (20.30.110) *Setbacks are measured from property line to finished surface, unless otherwise specified. Front: 10' Left Side: 4' Right Side: 4' Rear: 10' Other: 26. Third Floor Step-backs (20.48.180A.2.c.) (Applicable to single- and two-unit dwellings in the R-1, R-2, R-BI, and RM zoning districts ) Front: Left Side: Right Side: Rear: N/A: N/A NO THIRD FLOOR FROM MAIN ACCESS OFF OF OCEAN BLVD. • Enclosed floor area and covered decks located on the third floor shall be stepped back a minimum of 15 feet from the front and rear setback lines. • For lots 30 feet in width or greater, a minimum step back of 2 feet from each side setback line shall also be required, including bay windows. 27. On residential lots wider than thirty (30) feet, if the primary entrance to a dwelling faces a side setback area the entry door shall be set back a minimum of five feet from the side property line and a three-foot-wide unobstructed walkway shall be provided up to a minimum height of eight feet between the primary entrance and the public street or alley. 28. 1 A minimum thirty-six (36) inch wide passageway shall be maintained within at least one side setback area adjacent to the principal structure. The passageway shall be free of any encroachments or obstructions from ground level to a height of eight feet, including mechanical equipment, and other items attached to, or detached from, the principal structure. 29. Comments: FLOOR AREA/SITE AREA LIMITATIONS 30. Lot Size: 10,912 square feet Lot Dimensions: See attached subdivision map with dimensions 31. 2 Buildable Area: lot area minus required setback areas = MKN 2/14 Comment: 10,219 SF PER PRIOR VARIANCE PLANS. PROVIDE A BUILDABLE AREA CALCULATION ON THE COVER SHEET OF THE PLANS. PROVIDE A SUPPORTING EXHIBIT IF NECESSARY TO DEMONSTRATE THE LOT AREA LESS THE SETBACKS FOR THIS UNUSUALLY SHAPED LOT. DL Comment: See MKN's comment 33 below. This may have been worked out but please provide explanation. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\Admin\Energov\PLNG PC2022-3232 CO DL 2023-04-26.docx (pw_CDD) Page 4 of 11 32. Floor Area Limitation: 1.5 x buildable area + (200 Square Feet for R-BI only) = 15,328 maximum square footage • Calculation includes exterior walls, stairway(s) on first level of occurrence, enclosed spaces (finished or unfinished) with a ceiling height of 6 feet or greater, daylighting basements, and enclosed parking (including subterranean) • Calculation does not include subterranean basements. • Covered patios must be open on one side on 1st floor and open on at least two sides above first floor, otherwise area shall be included as floor area. • Required openings for covered patios may include required safety railings and minimal structural supports. Railings shall be constructed of transparent material or opaque material that is at least 40% open. 33. 2 Proposed Floor Area: 8,292.45 square feet MKN 2/14 comment: PROVIDE THE PREVIOUSLY AGREED UPON SQUARE FOOTAGE EXHIBITS IN THE PLAN SET. THE EXISTING FLOOR AREA IS 5,564 SF PER THE ORIGINAL VARIANCE APPROVAL AND PC1664-1991 REMODEL PLANS. PLEASE CLARIFY ANY DISCREPANCIES SHOWN WITH THE EXISTING FLOOR AREA CALCULATION PROVIDED ON SHEET A025. DL Comment: The existing floor area on plans is 5,781 sq. ft. Can you explain the discrepancy between the two numbers? This may have been worked out but it would be helpful for the narrative to be included in the response. MKN 2/14 comment: CORRECT THE BUILDABLE AREA REFERENCED THROUGHOUT THE SET TO MATCH THE PREVIOUS VARIANCE PLANS (10,219SF). REFERENCE THE FLOOR AREA LIMIT AS WELL (BA X 1.5). DL Comment: The plans don't match these numbers. Again, this may have been worked out but please provide written explanation on why it differs. 34. Site (Lot) Coverage Limitation: n/a percent of total lot area • Calculation includes the percentage of a site covered by structures, including eaves and overhangs, and accessory structures and by decks more than 30 inches in height. 35. Proposed Lot Coverage: square feet or percent of total lot area 36. 2 Provide a floor area calculations exhibit (to scale) verifying proposed square footage (show dimensions & calculations). Provided. But see comment 33 above as it relates to the floor area calcs. 37. Comments: For 38 - 41, applicable to all single- and two-unit dwellings in the R-1, R-2, and R-BI zoning districts, except: lots 25 feet wide or less in R-2 38. Third Floor Area Limitation (20.48.180.A.2.a) 15% of the total buildable area for lots wider than 30 feet: Maximum: 0.15 x buildable area = Proposed: 20% of the total buildable area for lots 30 feet wide or less: Maximum: 0.20 x buildable area = Proposed: • 39. Comments: 40. Combined Third Floor Area and Covered Deck Limitation (20.48.180.A.2.b) 50% of the total buildable area: Maximum: 0.5 x buildable area = Proposed: Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\Admin\Energov\PLNG PC2022-3232 CO DL 2023-04-26.docx (pw_CDD) Page 5 of 11 41. Comments: For 42-43, applicable to all single- and two-unit dwellings in the R-1, R-2, R-BI, and RM zoning districts, except: lots 25 feet wide or less in R-2 42. Open Volume Area Required (20.48.180.A.3) 15% of the buildable area of the lot in addition to the required setback areas Required: 0.15 x buildable area: 1,004 square feet Proposed: 3,220 square feet • Open volume must be located within the buildable envelope (within the setback; under 24 FEET) • Open Volume must have a minimum dimension of 5 feet in depth from the setback line on which it is located • Open volume must be open on a minimum of one side and have minimum clear vertical dimension of 7.5 feet 43. Comments: Updated. PLOT PLAN/SITE PLAN/FLOOR PLANS 44. 2 Provide fully dimensioned Site Plan and Floor Plans. See all comments on Site Plan/Floor Plans. 45. Show the location of all buildings on-site and dimension distance to property lines. 46. Dimension the distance from face of curb to front property line (verify with Public Works). 47. Indicate the second and third floor footprints (if applicable). 48. Dimension all projections (e.g., fireplaces, bay windows, eaves), label distance(s) to property lines. 49. Provide separate existing and proposed floor plans fully dimensioned showing all room uses for all buildings on-site. Existing floor plans shall illustrate walls to be demolished 50. 2 Plot property lines on site plan and all floor plans with setbacks dimensioned. MKN 2/14 Comment: Dimension all setbacks from property line to face of finish of the existing/proposed structure. Setbacks provided appear to be to the eaves? DL Comment: Add a note: All setbacks dimensioned from property line to face of finish. 2. See red marks on new eave into setback. Minimum 24" clear between side property line and new eave. Eave of existing residence is nonconforming but allowed to remain. 51. Indicate the location of easement(s) plotted on site plan. 52. 2 Comments: 1. Remove specific walls/rails as indicated on Site Plan. 2. There are two entry gates. Please pick one gate (Staff prefers the one that is not on Ocean Blvd). Seems like both gates would exceed curb height and it would be difficult to justify allowing for both. Provide height of gate. 3. Provide all requested wall/railing dimensions as indicated on plans. Add elevation indicators to the plotted contours to match the surveys. Also, add existing grade points at all wall/rail height callout locations. See all red marks and address all comments from plans. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\Admin\Energov\PLNG PC2022-3232 CO DL 2023-04-26.docx (pw_CDD) Page 6 of 11 OFF-STREET PARKING (20.40) Single-Unit Dwellings – Attached 2 per unit in a garage Single-Unit Dwellings – Detached and less than 4,000 sq. ft. of gross floor area* 2 per unit in a garage Single-Unit Dwellings – Detached and 4,000 sq. ft. or greater of gross floor area* 3 per unit in a garage Single-Unit Dwellings – Balboa Island 2 per unit in a garage Two-Unit Dwellings 2 per unit; 1 in a garage and 1 covered or in a garage Other: *Gross Floor Area in this case shall include the square footage of basements, but shall not include the square footage of garages. Minimum Interior Dimensions The minimum interior dimensions for parking spaces in residential zoning districts shall be as provided below (unless otherwise stated in a Planned Community). The Director may approve a reduced width for duplex units when two separate single car garages are proposed side by side and the applicant has proposed the maximum width possible. Lot Width Single Car/Tandem* Two Car Three Car 30 feet or less 9’-3” x 19’ (35’)* 17’-6” x 19’ - 30.1 - 39.99 feet 10’ x 19’ (35’)* 18’-6” x 19’ 26’-9” x 19’ 40 feet or more 10’ x 20’ 20’ x 20’ 28’-3” x 20’ * The minimum depth for a 2-car tandem space is 35 feet 53. Gross Floor Area for purposes of calculating the number of parking spaces: Gross Floor Area (don't include garage) + Basement = 8,292 SF 54. Number of Parking Spaces Required: 3 Minimum interior clear dimensions required: 10' x 20' each 55. Label interior clear dimensions of the garage free of all obstructions such as cabinetry, appliances, steps, posts, etc. (one riser is allowed, maximum 6 inches high, encroaching no more than 18 inches into garage). 56. Indicate on the plans that the garage doors are automatic roll-up doors. Garages with doors that face the street that are located within twenty (20) feet of the front property line are required to be equipped with automatic roll-up doors. 57. Development on lots with alley access shall be designed such that parking is accessed from alley to minimize or eliminate curb cuts. Exceptions permitted only in compliance with Council Policy L-2; and for properties in coastal zone, compliance with Section 21.40.070.B and C required. 58. Comments: HEIGHT LIMITATION (20.30.060) • 20.30.050 Grade Establishment • Measured from average grade if slope is 5% or less • Roofs over the Flat Roof Limit must have a minimum 3:12 pitch • Sloped roofs with a pitch less than 3:12 and parapets, railings, etc are considered flat roof for the purpose of height limits • Heights are measured to the top of all finished materials. • Height certification will be required in some cases 59. Flat Roof Limit: 24 feet Sloped Roof Allowable Ridge Height: 29 feet 60. Height certification inspection required? Yes No If so, add note to elevations stating Height Certification Required. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\Admin\Energov\PLNG PC2022-3232 CO DL 2023-04-26.docx (pw_CDD) Page 7 of 11 61. Provide topographic survey (stamped and signed by a licensed surveyor) to establish slope and average grade or, use subdivision grading plan, if applicable. 62. Provide a sheet showing the outline of the proposed structure over a topographic survey to verify determination of slope and grade to be used for measuring height. 63. Provide slope of the lot. The slope of a lot shall be determined using a four-sided polygon that most closely approximates the actual footprint of the proposed structure. The area of the four-sided polygon shall not be smaller than the footprint of the proposed structure and shall be located entirely within the buildable area of the lot. Identify the elevation points from survey and distance used to calculate slope. 64. Establishment of Grade (Five Percent or Less Slope)- The grade of the surface from which structure height is measured shall be a plane established using the average of the elevations at each corner of the four-sided polygon. Example: A + B + C + D = X; X/4 = Established grade elevation from which to measure structure height. Identify the four points used to determine grade plane on site plan and illustrate average grade calculation. 65. 2 Establishment of Grade (More than Five Percent Slope)- The established grade from which structure height is measured shall be a plane established by determining the elevation of the lot at five evenly spaced points along each of the two side property lines and connecting each of the points along a side property line with the corresponding point on the opposite side property line. The five evenly spaced points along each side property line shall be located so that one point is located at the intersection of the front setback line with the side property line and another point is located at the intersection of the rear setback line with the side property line. The other three points along the side property line shall be located so that all five points are equidistant from each other. Provide a grade plane exhibit per the methodology above and clearly identify the survey points used to establish the grade plane. Cannot see bottom left corner point on exhibit. Indicate the elevation used at that corner. Also, provide calculation for each interpolated grade point. 66. Label the established grade on all elevation sheets. 67. For lots with a more than 5 percent slope, plot roof plan over established grade plan exhibit to assist with determination of grade points located directly below ridge peaks, roof areas and/or parapets. 68. Label interpolated grade points (based on established grade plane) below any critical ridge, parapet, etc. 69. Dimension heights from established grade to: top of flat roof ridge peak all roof top equipment deck rails any flat elements 70. All new structures shall have a minimum top of slab elevation of 9.0 (88 NAVD datum) pursuant to Section 20.30.060.B.3. When the top of slab is required to be raised, the height of the principal building shall be measured from the 9.0 (88 NAVD datum) elevation. 71. 2 Provide a complete roof plan. See comment 65 and 73. 72. Label roof pitches on roof plan and elevations. 73. 2 Label and dimension eave overhang to property line on all exterior elevations. New eave encroaches too far. Please see red marks. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\Admin\Energov\PLNG PC2022-3232 CO DL 2023-04-26.docx (pw_CDD) Page 8 of 11 74. 2 Comments: MKN 2/14 Comment: OVERLAY THE ROOF PLAN OVER THE GRADE PLANE. PROVIDE CRITICAL ROOFLINE/DECK ELEVATIONS AND CORRESPONDING EXISTING GRADE ELEVATIONS TO CONFIRM COMPLIANCE WITH THE HEIGHTLIMIT. 2:12 PITCH IS PROPOSED, DEMONSTRATE IT IS UNDER THE 24-FT FLAT ROOF HEIGHT LIMIT. DL Comment: This has been mostly demonstrated. See above comments about showing calculations and missing point (cut off from plans) MKN Comment: IDENTIFY THE CURB HEIGHT ELEVATIONS FROM THE TOPOGRAPHIC SURVEY ON THE ROOF PLAN AND SITE PLAN. DL Comment: There is curb height elevation(s) cut off from roof plan. Please include. EXCEPTIONS TO HEIGHT LIMITS (20.30.060 D) 75. 2 Interior Fireplaces- The overall chimney height for an interior fireplace is permitted to exceed the height limit by two feet above the roof plane plus an additional two foot maximum for the cap/spark arrestor. The additional two foot section is not only limited in height but also to 2 feet by 4 feet in width and depth. In addition, the chimney must be located a minimum distance of 10 feet from the nearest roof plane. Label dimensions of the chimney plus any portion of the cap/arrestor. Chimneys removed. Please update any renderings/exhibits which show proposed project with chimneys 76. Elevator Shafts/Enclosed Stairwells- Flat roofs above elevator shafts and enclosed stairwell housings may exceed the allowed height limit up to the maximum height for a sloped roof, provided they do not exceed thirty (30) square feet in area. Label applicable elevator shaft/enclosed stairwell dimensions and area. 77. Comments: LANDSCAPING 78. 2 LANDSCAPING – TITLE 14 Chapter 14.17 of the Municipal Code (Water-Efficient Landscaping) applies to landscape installation projects requiring a ministerial or discretionary permit and exceed the following thresholds: 1. New landscape project with greater than 500 square feet of landscape area 2. Rehabilitated landscaped project with greater than 2,500 square feet of landscape area New Landscape Project: total sq ft of new landscaped area Provide Landscape Documentation Package prepared in accordance with Design Standards or, if landscape area is 2,500 square feet or less, comply with the Prescriptive Compliance Option (Appendix H of Design Standards). Rehabilitated Landscape Project: total sq ft of rehabilitated landscaped area 1. Provide Landscape Documentation Package prepared in accordance with Design Standards or; 2. Rehabilitated projects with replacement plantings with equal or less water need than the existing landscaping and the irrigation system is designed, operable and programmed to comply with the City’s water conservation regulations are exempt from the ordinance and the requirement to provide a complete landscape documentation package. To qualify for this exemption, the applicant must provide a landscape and irrigation plan and letter from a licensed professional stating that the replacement landscaping and irrigation system complies with the terms of this exemption. 79. 2 Comments: Add notes on Landscape Plan as required by the Prescriptive Compliance option. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\Admin\Energov\PLNG PC2022-3232 CO DL 2023-04-26.docx (pw_CDD) Page 9 of 11 80. LANDSCAPING – TITLE 20 (20.36.050A) Impervious surfaces in R-1 and R-2 zones. 1. Impervious surface areas, excluding driveways, shall not exceed 50 percent of the front yard area with the remaining area landscaped with plant material. The use of pervious materials for walkways, porches, and outdoor living areas is allowed. 2. Where the typical neighborhood pattern of front yards has been developed with hardscaped outdoor living areas that exceed the 50 percent maximum for impervious surfaces the Director may waive this requirement. Project complies with: No.1 Yes No No.2 Yes No 81. 2 Comments: MKN 2/14 Comment: PROVIDE AN OVERALL PLANTING PLAN FOR THE ENTIRE SITE ON ONE SHEET (NOT BY LEVEL). REMOVE THE 36" BOX MARINA STRAWBERRY TREES PROPOSED WITHIN THE 10' FRONT SETBACK AREA. THE ANTICPATED GROWTH HEIGHT OF THIS VEGETATION MAY POSE A CONFLICT WITH PUBLIC VIEWS FROM OCEAN BOULEVARD AT THIS LOCATION. (SEE SHEET L504 FOR EXAMPLE) DL Comment: Add a note: All landscaping, including trees, on private property shall be maintained to be below the highest point of the residence. Please note that this will be a proposed condition of approval. DESIGN CRITERIA (20.48.180 B.) For 78-83 below, applicable to all single-unit and two-unit residential building citywide 82. Walls: Long unarticulated exterior walls are discouraged on all structures. The visual massing of a building should be reduced by incorporating appropriate design elements; including variation in the wall plane, building modulation, opening, recesses, vertical element, varied textures, and design accents (e.g. moldings, pilasters, etc.). Front facades shall include windows. 83. Upper floors: Portions of upper floors should be set back in order to scale down facades that face the street, common open space, and adjacent residential structures. Upper story setbacks are recommended either as full length “stepbacks” or partial indentations for upper story balconies, decks, and/or aesthetic setbacks. 84. Architectural treatment: Architectural treatment of all elevations visible from public places, including alleys, is encouraged. Treatments may include window treatments, cornices, siding, eaves, and other architectural features. 85. Front façade: Where the neighborhood pattern is for the primary entrance to face the street, the primary entry and windows should be the dominate elements of the front façade. Primary entrances should face the street with a clear, connecting path to the public sidewalk or street. Alternatively, entry elements may be visible from the street without the door necessary facing the street. 86. Main entrance: The main dwelling entrance should be clearly articulated through the use of architectural detailing. 87. Comments: MISCELLANEOUS ITEMS 88. TWO- TO FOUR-UNIT DWELLING PROJECTS A notice shall be signed by property owners and copied into the plan set prior to the issuance of a building permit for development of two- to four-unit dwellings. The notice serves as a record of acknowledgement that property owners understand should they choose to pursue the approval of a Parcel Map for condominium purposes during the construction, they fully understand that the Parcel Map application is a discretionary process and is not guaranteed. 89. CONDOS - (Existing Structures) Before a condominium unit may be sold, a condominium conversion building permit must be signed off by the Planning Department. The Parcel Map must be signed off by the Public Works Department, approved by the County and RECORDED at the County. Proof of recordation will be required before Planning can sign off on the building permit final. Provide a copy of the first page of the recorded document. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\Admin\Energov\PLNG PC2022-3232 CO DL 2023-04-26.docx (pw_CDD) Page 10 of 11 90. CONDOS - (New Structures) Before a condominium unit may be sold, a building permit is required for a description change from “duplex” to “condominiums.” Before building permits can be finaled, the Parcel Map must be signed off by the Public Works Department, approved by the County and RECORDED at the County. Proof of recordation will be required before Planning can sign off on the description change. Provide a copy of the first page of the recorded document. 91. 20.30.130 (Traffic Safety Visibility Area): Design includes accessory improvements and/or landscaping within traffic safety visibility triangle: Yes No • If Yes, label and illustrate traffic safety visibility triangle as follows: • Label proposed improvements and heights within triangle as follows: 92. 20.30.020.A (Screening of Roof-Mounted and Ground-Mounted Mechanical Equipment)- The screening of mechanical equipment is required in all zoning districts at the time of new installation or replacement. Roof-mounted and ground-mounted mechanical equipment (e.g., air conditioning, heating, ventilation ducts and exhaust vents, swimming pool and spa pumps and filters, transformers and generators, and similar equipment, but excluding solar collectors and related equipment), shall be screened from public view and adjacent residential districts, and shall comply with the requirements: 93. 2 ACCESSORY STRUCTURES Accessory structures, including fences, hedges, walls, and retaining walls, are typically limited to 6 feet in side and rear setbacks and 42 inches in front setbacks. Please label height from natural grade below to highest point of structure. MKN 2/14 Comment: CONSISTENTLY SHOW TOP OF WALL AND EXISTING GRADE ELEVATIONS FOR ALL PROPOSED SITE WALLS ON THE ARCHITECTURAL SITE PLAN, LANDSCAPE PLANS, AND CIVIL GRADING PLANS. SOME PROPOSED SITE WALLS APPEAR TO BE MISSING ENTIRELY FROM THE CIVIL PLANS. BE SURE TO INCLUDE FINISHED SURFACE AND EXISTING GRADE ELEVATOINS FOR THE PROPOSED COURTYARD AREAS AS WELL. INCLUDE TOP OF CURB ELEVATION POINTS TO IDENTIFY COMPLIANCE WITH THE HEIGHT LIMIT ALONG OCEAN BOULEVARD AS WELL. DL Comment: See all red marks on Site Plan and provide EG call outs for all walls and railings. Please verify that they match Civil Plans. 94. FYI ASSOCIATION APPROVAL (ADVISORY) Issuance of a Building Permit by the City does not relieve applicant of legal requirement to observe covenants, conditions and restrictions which may be recorded against the property or to obtain community association approval of plans. 95. TRASH AREA Indicate the location of the screened trash area on the site plan or floor plan. 96. Comments: GENERAL NOTES 97. Add the following note(s) as indicated below: “Pools, spas, walls, fences, patio covers and other freestanding structures require separate reviews and permits.” “Fences, hedges, walls, retaining walls, guardrails and handrails or any combination thereof shall not exceed 42 inches from existing grade prior to construction within the required front setback area(s).”DIMENSION GUARDRAILS HEIGHTS AS WELL AS RETAINING WALL HEIGHTS IN 10-FT FRONT SETBACK. Accessory Living Areas- “There shall be no facilities used for food preparation within or be used for residential purposes separately or independently from occupants of principal structure.” Other:- HOLD ON FINAL Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\Admin\Energov\PLNG PC2022-3232 CO DL 2023-04-26.docx (pw_CDD) Page 11 of 11 98. FYI The following Hold(s) on Final will be applied to your building permit: Height Certification of critical roof height elevations. Condominium Conversions- Parcel Map recordation. New Condominiums (1-4 units) - Parcel Map recordation and issuance of Description Change permit Landscape Certification- For projects requiring landscape documentation package, applicant must provide third-party stamped and signed Certificate of Completion (Appendix E of Design Standards), Third Party Audit, and Post-Installation Irrigation Schedule and Maintenance Schedule. Accessory Dwelling Units: Deed Restriction and Affordability Questionnaire Other:- 99. Comments: PROVIDE CUT/FILL CY CALCULATIONS FROM THE GRADING PLAN ON THE CUT/FILL EXHIBIT AS WELL FOR CLARITY AND EASE OF REFERENCE.