HomeMy WebLinkAboutH2020-0559 - Misc (3)CERTIFICATE OF COMPLIANCE CHR-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Simmons, Clase A
Company:
Signature Date:
GUARANTEED AIR
2020-09-17 13:22:26
Address:
CEA/ HERS Certification Identification (If applicable):
1250 N. Lakeview Ave. Suite C
City/State/Zip:
Phone:
Anaheim CA 92807
714-777-6600
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. Thatthe energyfeatures and performance specifications, materials, components, and manufactured devices forthe building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible Designer Signature:
Simmons, Clase A`0�a-�`r`"�'rO
Company:
Date Signed:
GUARANTEED AIR
2020-09-17 13:22:26
Address:
License:
1250 N. Lakeview Ave. Suite C
997377
City/State/Zip:
Phone:
Anaheim CA 92807
714-777-6600
0
Easy to Verify
at CaICERTS.com
y
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
❑� _
R st atien orniiidor r<ennnclhlnfv fnr the accuracv of the Information.
_
er 9
Registration Number: 220-A020172855A-000-000-0000000-0000
Registration Date/Ti me: 2020-09-17 13:22:26
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.003 Report Generated: 2020-09-17 13:21:52
C, o— ve—i— ro.. 7mnnnn1
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC)
Project Name:
Ron White I Date Prepared:
CF1R-ALT-02-E
(Page 1 of 3)
2020-09-17
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
Ron White
02
Date Prepared
2020-09-17
03
Project Location
500 39th St.
04
Building Type
Single family
OS
CA City
Newport Beach
06
Dwelling Unit Name
Ron White
Dwelling Unit Conditioned Floor
07
Zip Code
92663
OS
Area (ftz)
1200
Number of Space Conditioning
09
Climate Zone
6
10
(SC) Systems in this Dwelling
1
Unit:
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
SC System ID or
SC System
CFA served b this
y
Is the SC system a
y
Installing a
refrigerant
g
Installingnew SC
Installing more
g
than 40 feet
Installing entirely
Installing entirely
Alteration Type
Name
Location or Area
SC System (ft2)
ducted system?
containing
system
y
components?
of
ducts?
new duct system?
new SC system?
Served
component?
Altered space
System 1
Location 1
1200
Yes
Yes
Yes
No
No
No
conditioning
system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)IDiib)
This section does not apply to this project.
Registration Number: 220-A020172855A-000-000-0000000-0000
Registration Date/Time: 2020-09-17 13:22:26
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.003 Report Generated: 2020-09-17 13:21:52
--inonnnm
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC)
(Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)IE and F)
01
02
03
04
05
06
07
08
09
10
11
12
13
SC System
Heating
Cooling
Description
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
System ID/
of Area
Heating
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
Name
Served
System Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R-Value
System 1
Location 1
Central gas
All new
heating
AFUE
80
Centrals lit
p
All new
cooling
SEER
16
Setback
Less than or
equal to 40
R-6
furnace
components
AC
components
feet
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: <= 15 percent or <= 10 percent leakage to outside, or seal all accessible leaks.
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH-25 is required.
Exceptions:
- Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
- Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)IE, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 220-A020172855A-000-000-0000000-0000
Registration Date/Time: 2020-09-17 13:22:26
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards- 2019 Residential Compliance Report Version: 2019.1.003 Report Generated: 2020-09-17 13:21:52