Loading...
HomeMy WebLinkAboutXR2023-1437 - Alternative Material & MethodsXV_ZD23 -PA67 41-;W Po/�T r . cg4FoaN P CITY OF NEWPORT BEACH RECEIVED BY COMMUNITY COMMUNITY DEVELOPMENT DEPARTMENT DEVELOPMENT BUILDING DIVISION AUG 2I 2023 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 CASE NO.: ❑ REQUEST FOR MODIFICATION TO PROVISIONS OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE) OF THE NEWPORT BEACH MUNICIPAL CODE (See Reverse for Basis for Approval) (Fee $306) REQUEST FOR ALTERNATE MATERIAL OR METHOD OF CONSTRUCTION (See Reverse for Basis for Approval) (Fee $306) For above requests, complete Sections 1, 2 & 3 below by printing in ink or typing. JOB ADDRESS: SITE ADDRESS: 2201 Waterfront Dr. owner Irving BUdlong Address 2201 Waterfront Dr. Corona Del Mar zip 92625 Daytime Phone ( 949) 230-0601 illustrate TION/FINDINGS OF EQUIVALENCY: The eDoxv will CITY OF NEWPORT BEACH FOR STAFF USE ONLY Plan Check # fp G &.7 3 - 13 0 of Stories NR Occupancy ClassiClassificationk Use of Building i05-1 A11Ji q16 W A LL # of Units ly A Project Status iL A-N C 146,CX Construction Type N A Verified by f�5 No. of Items / Fee due t-?,O Owner 29 Plan Check K - 6'S• Petitioner ❑ Inspector Fire ❑ Other PETITIONER: Petitioner Farhad Manshadi P.E. (Peatlonw to be amhftwt or anglrner) Address 1800 E. 16th St. Santa Ana zip 92701 Daytime Phone ( 949) 835-2800 Email: farhad@esifine.com ACI 318-10.136.8, ACI 318-7.7.1 Petitioner's Position Farhad Manshadi P.E. / Signature /`P - CA Professional Lic. # C 36840 Date: 08/13/2023 FOR STAFF USE ONLY DEPARTMENT ACTION: In accordance with: ZfCEC 104.11/CFC 104.9 (Altemate materials & methods) ❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved —_� By: Date Request (DOES)'( OE O lessen any fire protection requirements. quest (DOES) (=essen the structural integrity ❑ CBC 104.10/CFC 104.8 (CBC Modification) ❑ Written Comments Attached The Request is: ,Granted ❑ Denied (See reverse for appeallnformadon) ❑ Granted (Ratification required) Conditions of Approval: -- - --- — '� CHIEF BUILDING OFFICIAL Signature Position Print Name Date 045- ZS - Zc L APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse) (Signature, statement of ownerorapplicant, statement of reasons for appeal and filing fees are required.) CASHIER RECEIPT NUMBER: W a olt0121 '102ForrnsUnodif 08/21/23 - 27 I ` O x `v 17(J� 6 13 G � ' O/v� �. 7 i 161. i 7� x `'' )t1 44;1 10.4 Do coo x iJ � fF: �c O \' g II s C3 6> T 7 L cnK:mK:�E �: rx o>v mZp�-1> OA WCDo ZrA OC �mm0 II A �p O v „n�aAA 8' wN® =om O OZ A M �c-ZIm Om AO W-�I� r+Ai T Ozm>�Z� O vm �z Tv NNv mom n r e e l m < °° o Z 0 O� c Z T r ° ° I m 'Om9Z= m m ICI r m ° ��� (A y _> �eI o u _ Oz A � 0 v z T O !rn C LK p I° N 00 0 -m N Z� p O> :I a moN -10 �G ? Vi ° • ° I Z = Z m � C X ®® ° Z C A m O D �k m -� m A m Z T N N m O O A m 70 y m O N o o 1,. A o mo o cn n 622 22 :2 m w —1 m x CLR. LR. ;N �; m O N A A x m N CeN r Z r O m m m0 Z n r m O 0 A Z C) —_ Z O Z OmI m z m O Z co �IZ r 8 NW N Z =0 O > II � Z D I� N m x II°d—r ` carboline Coatings - Linings -Fireproofing SELECTION & SPECIFICATION DATA Generic Type I Coal tar epoxy Bitumastic 300M PRODUCT DATA SHEET Description I Renowned high build coal tar epoxy for protection of steel and concrete in single or two -coat applications in a broad variety of aggressive industrial applications. Features • Excellent chemical, corrosion and abrasion resistance High build, 400 to 600 microns in a single coat (up to 875 microns with force curing) • Compatible with controlled cathodic protection • Suitable for use in exposures as referenced in the following specifications Corp of Engineers C-200, C200a AW WA C-210 for exterior • SSPC-Paint 16 • Steel Tank Institute Corrosion Control System STI-P3 Color I Black and Red Primer I Self -priming, or use suitable primer as recommended by StonCor Africa. 400 microns, in one or two coats Dry Film Thickness Total dry film thickness less than 200 microns or in excess of 875 microns is not recommended. Wet -on -wet spray techniques should be used for high thicknesses allowing time for solvents to flash between passes. Solid(s) Content 174% t 2% Theoretical Coverage 1.8m'/litre at 400 microns Rates Allow for loss in mixing and application VOC Value(s) Thinner # 10 (8%): 269 g/I As Supplied: 222 g/I Dry Temp. Resistance Continuous: 177°C (351 °F) Non -Continuous: 188°C (370°F) Limitations I Do not use for potable water requirements. Topcoats I Not recommended. Wet Temp. Resistance I Immersion temperature should not exceed 49°C SUBSTRATES & SURFACE PREPARATION General I Surfaces must be clean and dry. Employ adequate methods to remove dirt, dust, oil and all other contaminants that could interfere with adhesion of the coating. Immersion: ISO8501 Sat/2 Steel Non -immersion: ISO 8501 Sa2 ISO St2 or St3 as minimum requirement Surface Profile: 50 to 75 microns Concrete must be cured 28 days at 24°C and 50% relative humidity or equivalent. Prepare Concrete or CMU surfaces in accordance with ASTM D4258 Surface Cleaning of Concrete and ASTM D4259 Abrading Concrete. Voids in concrete may require surfacing. November 2021 300M Page 1 of 4 Bitumastic 300M PRODUCT DATA SHEET PERFORMANCE DATA (TYPICAL VALUES roatings -Linings -Fireproofing Test Method System Results No blistering, rusting or delamination. ASTM B117 Salt Fog Blasted steel 2 Coats 300M No measurable undercutting at scribe after 2000 hours ASTM D2794 Impact Blasted steel 2 Coats 300M Impact site diameter, 9.5, 9.5, 12.7 5.6m/ kg Gardner Impactor at 12.7mm diam ASTM D4541 Adhesion Blasted steel 2 Coats 300M 9.9 MPa (Pneumatic) Test reports and additional data available upon written request. * Disclaimer: Bitumastic 300M is a proprietary formula that is not necessarily formulated to the exact compositional guidelines set forth in some of these standards. Major deviations that control and improve application characteristics may be present, but does not have a detrimental effect on the suitability for use outlined therein. MIXING & THINNING Mixing Power mix separately, then combine and power mix for a minimum of two minutes. DO NOT MIX PARTIAL KITS. Up to 15% with Thinner # 10 Thinning Up to 20% with Thinner # 10 for the first coat application to concrete. Use of thinners other than those supplied or recommended by StonCor Africa may adversely affect product performance and void product warranty, whether expressed or implied. Ratio 14:1 Ratio (A to B) 2 Hours at 24*C Pot Life 1 Hour at 32°C Pot life ends when coating loses body and begins to sag. APPLICATION EQUIPMENT GUIDELINES Listed below are general equipment guidelines for the application of this product. Job site conditions may require modifications to these guidelines to achieve the desired results. This is a high solids coating and may require adjustments in spray techniques. Wet film thickness Spray Application is easily and quickly achieved. The following spray equipment has been found suitable and is available from manufacturers such as Binks, DeVilbiss and Grace. Conventional Spray I Pressure pot equipped with dual regulators, 3/8" I.D. minimum material hose, with 50' maximum material hose .086" I.D. fluid tip and appropriate air cap. Airless Spray Pump Ratio: 30:1 * GPM Output: 3.0 (min) Material Hose: Y:" I.D. (min) Tip Size:.025-.035" Output PSI:2100 to 2500 Filter Size: 30 Mesh * Teflon packings are recommended and available from the pump manufacturer. Brush & Roller Recommended for touch-up, striping of weld seams and hard -to -coat areas only. Avoid excessive (General) re -brushing or re -rolling. Brush I Use a medium bristle brush. November 2021 300M Page 2 of 4 carboline Coatinge -Linings -Fireproofing APPLICATION EQUIPMENT GUIDELINES Bitumastic 300M PRODUCT DATA SHEET Listed below are general equipment guidelines for the application of this product. Job site conditions may require modifications to these guidelines to achieve the desired results. Roller I Use a short -nap synthetic roller cover with phenolic core. APPLICATION CONDITIONS Condition Material Surface Ambient Humidity Minimum 10-C (50-F) 10°C (50-F) 10°C (50-F) 0% Maximum 32-C (90-F) 52-C (126-F) 43-C (109-F) 90% Condensation due to substrate temperatures below the dew point can cause flash rusting on prepared steel and interfere with proper adhesion to the substrate. Special application techniques may be required above or below normal application conditions. CURING SCHEDULE Surface Temp. Dry to Touch Final Cure Immersion Maximum Recoat Time Minimum Recoat Time 10°C (50°F) 8 Hours 14 Days 24 Hours 10 Hours 24°C (75-F) 4 Hours 7 Days 24 Hours 6 Hours 32°C (90-F) 2 Hours 5 Days 24 Hours 3 Hours Curing Details These times are based on a 400 micron dry film thickness. Higher film thickness, insufficient ventilation, high humidity or cooler temperatures will require longer cure times. Excessive humidity or condensation on the surface during curing can interfere with the cure, can cause discolouration and may result in a surface haze. Any haze or blush must be removed by water washing before recoating. If the maximum recoat time is exceeded, the surface must be abraded by sweep blasting prior to the application of additional coats. Holiday Detection (if required): Wet sponge types may be used if the dry film thickness is below 500 microns. High voltage spark testing should be used when the dry film thickness exceeds 500 microns. Refer to the latest version of NACE SP1088 for specific procedures. FORCE CURING recommended for thicknesses above 600 microns: Hold substrate at 65°C for 8 hours and material will be ready to handle for immersion service. CLEANUP & SAFETY Cleanup For equipment flushing and cleaning, use Thinner # 76 or Thinner # 2. Use Thinner # 85 in case of spillage, absorb and dispose of in accordance with local applicable regulations. Read and follow all caution statements on this product data sheet and on the material safety data Safety sheets for this product. Employ normal workmanlike safety precautions. Hypersensitive persons should wear protective clothing, gloves and use protective creams on face, hands and all exposed areas. This product contains flammable solvents. Keep away from sparks and open flames. All electrical Caution equipment and installations should be made and grounded in accordance with the National Electric Code. In areas where explosion hazards exist, workers should be required to use non-ferrous tools and wear conductive and non -sparking shoes. November 2021 300M Page 3 of 4 Bitumastic 300M PRODUCT DATA SHEET PACKAGING, HANDLING & STORAGE carbolule Coatings -Linings -Fireproofing Part A: Min. 24 months at 25'C Shelf Life Part B: Min. 24 months at 25'C Shelf life (actual stated shelf life) when kept at recommended storage conditions and in original unopened containers. Shipping Weight 5 Litre Lit (Approximate) Part A: 5.6kg Part B: 1.3kg Storage Temperature & 4 to 43°C Humidity 0 to 100% Flash Point(Pensky Part A:24°C Martens Closed Cup) Part B:93°C Storage I Store indoors WARRANTY To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject to change without prior notice. User must contact Carboline Company to verify correctness before specifying or ordering. No guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control. We assume no responsibility for coverage, performance, injuries or damages resulting from use. Carbolines sole obligation, if any, is to replace or refund the purchase price of the Carboline product(s) proven to be defective, at Carbolines option. Carboline shall not be liable for any loss or damage. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY CARBOLINE, EXPRESS OR IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. All of the trademarks referenced above are the property of Carboline International Corporation unless otherwise indicated. November 2021 300M Page 4 of 4