HomeMy WebLinkAboutXR2023-1437 - Alternative Material & MethodsXV_ZD23 -PA67
41-;W Po/�T
r .
cg4FoaN P
CITY OF NEWPORT BEACH RECEIVED BY
COMMUNITY
COMMUNITY DEVELOPMENT DEPARTMENT DEVELOPMENT
BUILDING DIVISION AUG 2I 2023
100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915
www.newportbeachca.gov 1 (949) 644-3200
CASE NO.:
❑ REQUEST FOR MODIFICATION TO PROVISIONS
OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE)
OF THE NEWPORT BEACH MUNICIPAL CODE
(See Reverse for Basis for Approval) (Fee $306)
REQUEST FOR ALTERNATE MATERIAL
OR METHOD OF CONSTRUCTION
(See Reverse for Basis for Approval) (Fee $306)
For above requests, complete Sections 1, 2 & 3
below by printing in ink or typing.
JOB ADDRESS:
SITE ADDRESS: 2201 Waterfront Dr.
owner Irving BUdlong
Address 2201 Waterfront Dr.
Corona Del Mar zip 92625
Daytime Phone ( 949) 230-0601
illustrate
TION/FINDINGS OF EQUIVALENCY:
The eDoxv will
CITY OF
NEWPORT BEACH
FOR STAFF USE ONLY
Plan Check # fp G &.7 3 - 13 0 of Stories NR
Occupancy ClassiClassificationk
Use of Building i05-1 A11Ji q16 W A LL # of Units ly A
Project Status iL A-N C 146,CX
Construction Type N A
Verified by f�5
No. of Items /
Fee due t-?,O
Owner 29 Plan Check K - 6'S•
Petitioner ❑ Inspector
Fire ❑ Other
PETITIONER:
Petitioner Farhad Manshadi P.E.
(Peatlonw to be amhftwt or anglrner)
Address 1800 E. 16th St.
Santa Ana zip 92701
Daytime Phone ( 949) 835-2800
Email: farhad@esifine.com
ACI 318-10.136.8, ACI 318-7.7.1
Petitioner's
Position Farhad Manshadi P.E.
/
Signature /`P - CA Professional Lic. # C 36840 Date: 08/13/2023
FOR STAFF USE ONLY
DEPARTMENT ACTION: In accordance with: ZfCEC 104.11/CFC 104.9
(Altemate materials & methods)
❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved
—_� By: Date
Request (DOES)'( OE O lessen any fire protection requirements.
quest (DOES) (=essen the structural integrity
❑ CBC 104.10/CFC 104.8
(CBC Modification)
❑ Written Comments Attached
The Request is: ,Granted ❑ Denied (See reverse for appeallnformadon)
❑ Granted (Ratification required)
Conditions of Approval:
-- - --- — '� CHIEF BUILDING OFFICIAL
Signature Position
Print Name
Date 045- ZS - Zc L
APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse)
(Signature, statement of ownerorapplicant, statement of reasons for appeal and filing fees are required.)
CASHIER RECEIPT NUMBER: W a olt0121 '102ForrnsUnodif 08/21/23
- 27
I ` O x `v
17(J�
6
13
G � ' O/v� �. 7
i 161.
i 7� x
`'' )t1 44;1 10.4
Do coo x
iJ
� fF:
�c O
\'
g
II
s
C3
6>
T
7
L
cnK:mK:�E �: rx o>v
mZp�-1> OA WCDo ZrA
OC �mm0 II A �p O
v „n�aAA 8' wN® =om
O OZ A
M �c-ZIm Om AO W-�I�
r+Ai T Ozm>�Z� O vm �z
Tv NNv mom
n r e e l m < °° o Z 0
O�
c Z T r ° ° I m 'Om9Z=
m m ICI r m ° ���
(A y
_> �eI
o
u _ Oz A
� 0
v z
T O
!rn
C LK p
I° N
00
0 -m N Z�
p O>
:I a moN -10
�G ? Vi ° • ° I Z = Z m � C X
®® ° Z C A m O D
�k m -� m A m Z T
N N m O
O A m 70 y m O
N o o 1,. A o mo o cn
n 622 22 :2 m w —1
m x CLR. LR. ;N �; m
O N
A A x m
N
CeN
r Z
r O m m
m0
Z n
r
m O
0
A
Z
C) —_
Z
O
Z
OmI
m
z
m
O
Z
co
�IZ
r
8
NW
N Z
=0
O >
II � Z D I�
N
m
x
II°d—r
`
carboline
Coatings - Linings -Fireproofing
SELECTION & SPECIFICATION DATA
Generic Type I Coal tar epoxy
Bitumastic 300M
PRODUCT DATA SHEET
Description I Renowned high build coal tar epoxy for protection of steel and concrete in single or two -coat
applications in a broad variety of aggressive industrial applications.
Features
• Excellent chemical, corrosion and abrasion resistance
High build, 400 to 600 microns in a single coat (up to 875 microns with force curing)
• Compatible with controlled cathodic protection
• Suitable for use in exposures as referenced in the following specifications
Corp of Engineers C-200, C200a
AW WA C-210 for exterior
• SSPC-Paint 16
• Steel Tank Institute Corrosion Control System STI-P3
Color I Black and Red
Primer I Self -priming, or use suitable primer as recommended by StonCor Africa.
400 microns, in one or two coats
Dry Film Thickness Total dry film thickness less than 200 microns or in excess of 875 microns is not recommended.
Wet -on -wet spray techniques should be used for high thicknesses allowing time for solvents to flash
between passes.
Solid(s) Content 174% t 2%
Theoretical Coverage 1.8m'/litre at 400 microns
Rates Allow for loss in mixing and application
VOC Value(s) Thinner # 10 (8%): 269 g/I
As Supplied: 222 g/I
Dry Temp. Resistance Continuous: 177°C (351 °F)
Non -Continuous: 188°C (370°F)
Limitations I Do not use for potable water requirements.
Topcoats I Not recommended.
Wet Temp. Resistance I Immersion temperature should not exceed 49°C
SUBSTRATES & SURFACE PREPARATION
General I Surfaces must be clean and dry. Employ adequate methods to remove dirt, dust, oil and all other
contaminants that could interfere with adhesion of the coating.
Immersion: ISO8501 Sat/2
Steel Non -immersion: ISO 8501 Sa2
ISO St2 or St3 as minimum requirement
Surface Profile: 50 to 75 microns
Concrete must be cured 28 days at 24°C and 50% relative humidity or equivalent. Prepare
Concrete or CMU surfaces in accordance with ASTM D4258 Surface Cleaning of Concrete and ASTM D4259
Abrading Concrete. Voids in concrete may require surfacing.
November 2021 300M Page 1 of 4
Bitumastic 300M
PRODUCT DATA SHEET
PERFORMANCE DATA (TYPICAL VALUES
roatings -Linings -Fireproofing
Test Method
System
Results
No blistering, rusting or delamination.
ASTM B117 Salt Fog
Blasted steel 2 Coats 300M
No measurable undercutting
at scribe after 2000 hours
ASTM D2794 Impact
Blasted steel 2 Coats 300M
Impact site diameter, 9.5, 9.5, 12.7 5.6m/
kg Gardner Impactor at 12.7mm diam
ASTM D4541 Adhesion
Blasted steel 2 Coats 300M
9.9 MPa (Pneumatic)
Test reports and additional data available upon written request. * Disclaimer: Bitumastic 300M is a proprietary formula that is not
necessarily formulated to the exact compositional guidelines set forth in some of these standards. Major deviations that control
and improve application characteristics may be present, but does not have a detrimental effect on the suitability for use outlined
therein.
MIXING & THINNING
Mixing Power mix separately, then combine and power mix for a minimum of two minutes. DO NOT MIX
PARTIAL KITS.
Up to 15% with Thinner # 10
Thinning Up to 20% with Thinner # 10 for the first coat application to concrete.
Use of thinners other than those supplied or recommended by StonCor Africa may adversely affect
product performance and void product warranty, whether expressed or implied.
Ratio 14:1 Ratio (A to B)
2 Hours at 24*C
Pot Life 1 Hour at 32°C
Pot life ends when coating loses body and begins to sag.
APPLICATION EQUIPMENT GUIDELINES
Listed below are general equipment guidelines for the application of this product. Job site conditions may require modifications
to these guidelines to achieve the desired results.
This is a high solids coating and may require adjustments in spray techniques. Wet film thickness
Spray Application is easily and quickly achieved. The following spray equipment has been found suitable and is
available from manufacturers such as Binks, DeVilbiss and Grace.
Conventional Spray I Pressure pot equipped with dual regulators, 3/8" I.D. minimum material hose, with 50' maximum
material hose .086" I.D. fluid tip and appropriate air cap.
Airless Spray
Pump Ratio: 30:1 *
GPM Output: 3.0 (min)
Material Hose: Y:" I.D. (min)
Tip Size:.025-.035"
Output PSI:2100 to 2500
Filter Size: 30 Mesh
* Teflon packings are recommended and available from the pump manufacturer.
Brush & Roller Recommended for touch-up, striping of weld seams and hard -to -coat areas only. Avoid excessive
(General) re -brushing or re -rolling.
Brush I Use a medium bristle brush.
November 2021 300M Page 2 of 4
carboline
Coatinge -Linings -Fireproofing
APPLICATION EQUIPMENT GUIDELINES
Bitumastic 300M
PRODUCT DATA SHEET
Listed below are general equipment guidelines for the application of this product. Job site conditions may require modifications
to these guidelines to achieve the desired results.
Roller I Use a short -nap synthetic roller cover with phenolic core.
APPLICATION CONDITIONS
Condition
Material
Surface
Ambient
Humidity
Minimum
10-C (50-F)
10°C (50-F)
10°C (50-F)
0%
Maximum
32-C (90-F)
52-C (126-F)
43-C (109-F)
90%
Condensation due to substrate temperatures below the dew point can cause flash rusting on prepared steel and interfere with
proper adhesion to the substrate. Special application techniques may be required above or below normal application conditions.
CURING SCHEDULE
Surface Temp.
Dry to Touch
Final Cure Immersion
Maximum Recoat Time
Minimum Recoat Time
10°C (50°F)
8 Hours
14 Days
24 Hours
10 Hours
24°C (75-F)
4 Hours
7 Days
24 Hours
6 Hours
32°C (90-F)
2 Hours
5 Days
24 Hours
3 Hours
Curing Details
These times are based on a 400 micron dry film thickness. Higher film thickness, insufficient
ventilation, high humidity or cooler temperatures will require longer cure times. Excessive humidity
or condensation on the surface during curing can interfere with the cure, can cause discolouration
and may result in a surface haze. Any haze or blush must be removed by water washing before
recoating. If the maximum recoat time is exceeded, the surface must be abraded by sweep blasting
prior to the application of additional coats. Holiday Detection (if required): Wet sponge types may be
used if the dry film thickness is below 500 microns. High voltage spark testing should be used when
the dry film thickness exceeds 500 microns. Refer to the latest version of NACE SP1088 for specific
procedures.
FORCE CURING recommended for thicknesses above 600 microns:
Hold substrate at 65°C for 8 hours and material will be ready to handle for immersion service.
CLEANUP & SAFETY
Cleanup For equipment flushing and cleaning, use Thinner # 76 or Thinner # 2. Use Thinner # 85 in case of
spillage, absorb and dispose of in accordance with local applicable regulations.
Read and follow all caution statements on this product data sheet and on the material safety data
Safety sheets for this product. Employ normal workmanlike safety precautions. Hypersensitive persons
should wear protective clothing, gloves and use protective creams on face, hands and all exposed
areas.
This product contains flammable solvents. Keep away from sparks and open flames. All electrical
Caution equipment and installations should be made and grounded in accordance with the National Electric
Code. In areas where explosion hazards exist, workers should be required to use non-ferrous tools
and wear conductive and non -sparking shoes.
November 2021 300M Page 3 of 4
Bitumastic 300M
PRODUCT DATA SHEET
PACKAGING, HANDLING & STORAGE
carbolule
Coatings -Linings -Fireproofing
Part A: Min. 24 months at 25'C
Shelf Life Part B: Min. 24 months at 25'C
Shelf life (actual stated shelf life) when kept at recommended storage conditions and in original
unopened containers.
Shipping Weight 5 Litre Lit
(Approximate) Part A: 5.6kg
Part B: 1.3kg
Storage Temperature & 4 to 43°C
Humidity 0 to 100%
Flash Point(Pensky Part A:24°C
Martens Closed Cup) Part B:93°C
Storage I Store indoors
WARRANTY
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject
to change without prior notice. User must contact Carboline Company to verify correctness before specifying or ordering. No
guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control. We assume no
responsibility for coverage, performance, injuries or damages resulting from use. Carbolines sole obligation, if any, is to replace
or refund the purchase price of the Carboline product(s) proven to be defective, at Carbolines option. Carboline shall not be liable
for any loss or damage. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY CARBOLINE, EXPRESS OR
IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. All of the trademarks referenced above are the property of Carboline International Corporation unless
otherwise indicated.
November 2021 300M Page 4 of 4