Loading...
HomeMy WebLinkAboutXR2023-2344 - Alternative Material & Methods��WPOR> CITY OF NEWPORT BEACH 04 e COMMUNITY DEVELOPMENT DEPARTMENT u » BDD.DING DIVISION 100 Civic Center Drive I P.O. Box 17681 Newport Beach, CA 92658-8915 .G�,ron"� www.newoortbeachcasiovl(949)644-3200 CASENCL: �Poz3- z5*1 RECEIVED BY COMMUNITY DEVELOPMENT FEB 0 2 2024 CITY OF NEWPORT BEACH FOR STAFF USE ONLY ❑REQUEST PROVISIONS TITLE (FIRE CODE) LE OF TITLE s (FIRE CODE) TITLE 18 (BUILDING CODE) Plan Check# 1: 401 -11 #ofswdm I H OF THE NEWPORT BEACH MUNICIPAL CODE Occupancy Cta Ion 3 U �l (See Reverse for Basis for Approval) (Fee $306) Use of Building s R 8, #of Unite I Project Status "Vol; ® REQUEST FOR ALTERNATE MATERIAL Construction Type VA —Air OR METHOD OF CONSTRUCTION Verified by (Sea Reverse for Basis for Approval) (Fee $308) No. of Items I Fee due Z D For above requests, complete Sections 1, 2 8 3 DISTRIBUTION: below by printing In Ink or typing. ❑ Owner ❑ Plan Check Petitioner ❑ Inspector ❑ Fire ❑Other Tj JOB ADDRESS: PETITIONER -- SITE ADDRESS: 4827 Dorchester Rd. Petitioner Christian Lieht Owner Amanda Rubenstein & Megan Prichard Address 4827 Dorchester Rd Address 1401 Orain St. #120 Corona Del Mar, CA Zip 92652 Newport Beach. CA Zip 92660 Daytime Phone (310 ) 279-3684 Daytime Phone (949) 851-8345 Eman: brianCalcjBght.net 2 REQUEST: Submit plans If necessary to illustrate request Additional sheets or date may be attached. weep screed 'onto allow flush finished surface elevation between interior and cx6crior su s USTIFICATION/FINOINGS OF EQUIVALENCY: CODE SECTIONS: R703.7.2.1 Weep screed shall be placed 2" minimum above exterior finished 2019 CRC surface w/ a corrosive restistant metal flashing behind which extends 6' minimum above and 6" minimum Blow the weep screed ched dolail r/ncipal Petitioners Signahrre Professional Uc. # 22334 Data: 01-31-24 FOR STAFF USE ONLY DEPARTMENT ACTION: Inaccordencewith: /66BC 104A1/CFC 104.9 ❑ CBC 104.10/CFC 104.8 (Alternate materials & methods) (CSC Modification) ❑ Conwnenm from Fire Code Official is required. []Approved ❑ Disapproved ❑ Written Comments Attached By: Data ,y. t jRequest (DOE lessen arrf Oreprokcdon requirements. _ Request(DOE (DOES lessen the structural integrity The Request is: EfA3mrdBd ❑Dented (See reverse for appeal information) ❑ Granted (Ratification required) Conditions of Approval: i Signatui --- — Posido GH1EF PIJII_CING OFFICID4elfe 2 �'7 ` Print Name — APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse) (Signature, statement of owner or applicant statement of reasons for appeal and filing fees are required.) CASHIER RECEIPT NUMBER: - — SZ /T 3� ' 21- 0�-j Formaunoda OMI/23 Guidelines for Approval of Alternate Materials. Desiqn and Methods of Construction Basis For Approval For the Chief Building Official and Fire Code Official or their designated agent to approve a request for modification or a request for alternate material or method of construction, he/she must determine that special, individual reasons exist that make compliance with the strict letter of the Code impractical and that equivalency is provided. The resulting condition must be in conformance with the spirit and purpose of the Code provisions involved and that such modification does not lessen fire protection, structural integrity or occupant safety. The applicant must provide sufficient information with this application to allow the above evaluation to be made. Requirements for Submittals The applicant design professional shall prepare a Written Report that describes the alternate proposal along with the applicable data listed below: • State specific code provisions for which alternative is requested and why request is being submitted. • Describe by code section those provisions for which alternative is desired. • Compare the proposed alternative versus the code requirements In terms of structural strength, suitability, effectiveness, fire resistance, safety and health impacts affecting the building or user of the building, • Demonstrate that the proposed alternative is compatible with balance of code requirements. • When applicable, specify how authoritative consensus document(s) are used to substantiate proposal. (Reference draft ICC Building Performance Code Commentary Section 1.4.2.3 for background information). • Provide assumptions, references, and documentation of evaluation methods utilized. This includes intended use, input data, anticipated outputs, and limitations of computer models and other analytical tools or methods. • Specify when and where special inspection and testing are required and the standards of acceptance for demonstrating compliance. Show how the proposed alternate, if accepted, will be identified on the job site. • Where land use restrictions and building setbacks are required, deed restrictions may be an appropriate method to ensure continued compliance. • State how and where alternate proposal is incorporated within construction plans and prepare plan amendments as necessary. The design professional has the responsibility to coordinate all construction documents and ensure compatibility between documents. • The report and design documents shall be dated, signed and stamped by the design professional according to the plan submittal procedure. • For alternate methods of design requests, the applicant shall set performance criteria for his design. Performance criteria shall be reviewed, amended and approved by the Building or Fire Code Official prior to start of design. Alternative Design Review/Verification The Chief Building Official or Fire Code Official has the responsibility to review design submittals for compliance to the adopted codes and procedures. If the Building or Fire Code Official does not have the expertise on staff to make a thorough and competent review, the Building or Fire Code Official shall select a consultant that possesses the necessary qualifications to perform a third -party or peer review. Cost of peer review shall be paid by applicant to the Building Division prior to commencing the review. • Verify that all applicable information and justifications listed above as requirements for submittals is received and verify that evaluation and design methods used by designer are appropriate to the alternative proposed. • Verify products are being used in accordance with their listing conditions as required by recognized listing agencies. If not avallable, require documentation and/or testing to demonstrate compliance with intent of code and Intended use. • Evaluate performance of material and possible flaws that could affect performance of material in its installed state. • The reviewer shall document that the submittal has been reviewed and accepted as meeting the alternative materials, design and methods of construction provisions of the code. If the Building or Fire Code Official is not satisfied that the applicant has met the conditions, the request should be denied in writing with the applicable reason(s). Inspection/Field Verification The alternate proposal as approved in the construction documents must be verified by inspection, and, where necessary, testing as follows: • To verify that alternate materials, systems and fabricated products comply with accepted design criteria and the manufacturers and engineer's installation procedures, inspectors should check product labeling, certification, quality assurance processes, and testing, as applicable. • When appropriate, an approved third party quality assurance inspection and tesfing service may be required for continuous and complex inspection and testing activities. This is intended to verify that construction complies with the code and the approved plans. Appeal from the determination or action of the Chief Building Official or Fire Code Official or their designated agent may be made to the Building and Fire Board of Appeals. To appeal, the applicant must provide special individual reasons that make compliance with the strict letter of the Code impractical. Appeals or ratifications pertaining to State Disabled Access Standards require complete evidence to substantiate that the proposed design is equivalent to that prescribed by that standards or that due to legal or physical constraints, compliance with the standards or providing equivalency would create an unreasonable hardship. Appeals must be submitted on the Appeal Form available at Permit Counter accompanied by the properfee. You will be noted in writing of the appeal hearing's time and date. ®m TYPICAL EXTERIOR WALL CLADDING Y / 24" CONTINUOUS BITUTHENE - 18" F '•: / ABOVE / 6" BELOW T.O. CONCRETE 12" CONTINUOUS 26 GA MIN. CORROSIVE RESISTANT FLASHING - 6" ABOVE & BELOW+?--• "'r O, LONcRE7Tj CORROSIV ERESISTANT WEEP SCREED INTERIOR / EXTERIOR FINISHED L�---4 SURFACE (TO MATCH @ DOORS) L (SLOPE EXTERIOR HARDSCAPE Z 2% MIN. TO DRAIN) N �INz EX-WEEP-0002(b) WEEP @ HARDSCAPE ° y a d HARDSCAPE BASE SLAB d e MIRADRAIN (OR EQUAL) DRAINAGE / EXPANSION BOARD HOUSE FOUNDATION/SLAB EARTH ALL METAL FLASHINGS AND WEEP SCREED SHALL BE OF SIMILAR MATERIAL TO AVOID GALVANIC CORROSION 3"=1,_0.1 > CL ® Npm 'g 4■ [ D o99 na - w m � n8 8 31 0�I Z 0 C � n v iD Z � 0 n n n< .'19l.w'JIW�^ ■ J •1 .Rfal:YllYo�■a■tp .�wpr�r� nu.vla■ I.ls�kY`e'i � i9�.a�i GYGIG lO mn.� r,eoeo � OR MA L` ueww DORCHEMR ROAD DINING ROOM' 16'x10' l pYEN�HG LIVING ROOM' 16'xi V 0 Q GARAGE 18'xi6' WN00W SCHEDULE . W SIZE (WxH) T1PE COMMENT 1 W-0" x 4'-0- SUDER 5 8'-0" x 6'-8- STIDER GLASS DOOR - IEMPEREO DOOR SCHEDULE LTR. SIZE (WxH) TYPE COMMENT A 3'-0" x e'-8" SOUD-CORE D 3'-O" x 8'-8" 20-MIN. RATED I SELF-aDSING `CEHING HIIG"I W-ti "'IIr IGHf or DPr WNL T'-ti FBUILDING CODE I TRAINER Can the two rooms shown above share Light & Ventilation from each other? GIVEN: Adjoining Wall Area: 16' x 8' = 128 sq.ft. Living Room Area: 16' x 1 V = 176 sq.ft. Wall Opening Area, 12' x T = 84 sq.ft. Dining Room Area: 16' x 10' =160 sq.8 For both rooms to share Light & Ventilation, opening in wall must be: Not less than half of the wall area: 128 sq.ft.12 = 64 sq.ft. < 84 sq.fL OK Not less than 1110 of the floor area of the interior room: 176 sq.ft 110 = 17.6 sq.ft < 84 sq.ft OK Not less than 25 sq.ft. in area: 25 sq.ft < 84 sq.ft. OK Determine if the two rooms are provided with enough natural Light & Ventilation Natural Light Calculation: 8% Required Living Room: 176 sq_ ft. x 8 %=14.1 sq.ft required Dining Room: 160 sq. ft. x 8 % =12.8 sq.ft. required Total Light 14.1 + 12.8 = 26.9 sq.ft. Window 1: 5' x 4' = 20.0 sq.fL Window 5: 8' x 6'-8" = 53.3 sq.ft Total Light &0 +53.3 = 73.3 sq.ft 73.3 sq.ft. provided > 26.9 sq.ft. required OK Natural Ventilation Calculation: 4% Required Living Room: 176 sq. ft. x 4 %= 7.0 sq.ft required Dining Room: 160 sq. ft. x 4 %= 6.4 sq.ft. required Total Vent.: TO + 6,4 =13.4 sq.it Window 1: Slider Type 50%openable 20.0 sq.ft x 50% = 10.0 sq.ft provided Window 5: Slider Type 50%openable 53.3 sq.ft x 50%= 26.7 sq.ft. provided Door A: 3'-0" x 6'-8" = 20.0 sa.ft Total Vent: 10.0 +26.7 +20.0 = 56.7 sq.ft. 56.7 sq.ft. provided > 13.4 sq.ft. required OK