HomeMy WebLinkAboutXR2022-2975 - Alternative Material & MethodsXfzZo22 - 7 gz1j- CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newi)ortbeachca.gov 1 (949) 644-3200 CAM IVfO 0Y OEVEIPMENr BAN 2 4 2024 CITY OE NEWpOr?TAF, M1.. CASE NO.: 2a23 — I12 FOR STAFF USE ONLY ❑ REQUEST FOR MODIFICATION TO PROVISIONS p 28� Z Cz' 3 OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE) Plan Check # [ # of Stories Q 3/V OF THE NEWPORT BEACH MUNICIPAL CODE Occupancy Classification VINEY # Units 2 (See Reverse for Basis for Approval) (Fee $306) Use of Building of Project Status pl 6514 ® REQUEST FOR ALTERNATE MATERIAL Construction Type T A� �� OR METHOD OF CONSTRUCTION Verified by (See Reverse for Basis for Approval) (Fee $306) No. of Items I 30 Fee due For above requests, complete Sections 1, 2 & 3 DISTRIBUTION: ❑ Owner ® Plan Check A21 below by printing in ink or typing. ® Petitioner ❑ Inspector ❑ Fire ❑ Other TJ JOB ADDRESS: PETITIONER: SITE ADDRESS: 919 E BALBOA BLVD Petitioner ROB INGRAM Owner JEREMY JERGENSEN (Petitioner to be architect or engineer) Address 3400 La Sierra Ave, STE C Address 47 HASTINGS RIVERSIDE, CA Zip 92503 LAGUNA NIGUEL Zip 92577 Daytime Phone (619 ) 886-4391 Daytime Phone ( ) Email: robin ram in structural.com 9 e9 2 REQUEST: Submit plans if necessary to illustrate request. Additional sheets or data may be attached. USE OF SIKA MB EPDXY MOISTURE BARRIER ON AN EXISTING CONCRETE SLAB AS AN ALTERNATIVE TO THE PRESCRIPTIVE REQUIREMENTS FOR A CAPILLARY BREAK AND VAPOR RETARDER IN CGBSC 4.505.2.1. A NON -HABITABLE GARAGE STORAGE ROOM SLAB IS UNLIKELY TO HAVE A VAPOR BARRIER UNDER THE SLAB. WE ARE USING THAT SPACE TO COVERT TO HABITABLE SPACE AS AN ADU. VAPOR BARRIER NEEDED PER CRC R506.2.3 3 1JUSTIFICATIONIFINDINGS OF EQUIVALENCY: CODE SECTIONS: SIKA MB IS A MOISTURE BARRIER SPECIFICALLY DESIGNED FOR MOISTURE PROTECTION CRC R506.2.3, CGBSC 4.505.2.1 UNDER FLOORING SYSTEMS AND MEETS ASTM F3010 AND ASTM E96 (WATER VAPOR PERMIABILITY RATING OF 0.06 G/M^2-24 HR-MMHG). IT WILL CONTROL INTERIOR MOISTURE EQUIVALENT TO A CAPILLARY BREAK AND VAPOR RETARDER. Position ENGINEER Petitioner's --� Signature CA Professional Lic. # C84830 Date: 11/30/2023 FOR STAFF USE ONLY DEPARTMENT ACTION: In accordance with: XCBC 104.11/CFC 104.9 ❑ CBC 104.10/CFC 104.8 (Alternate materials & methods) (CBC Modification) ❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved ❑ Written Comments Attached By: Date (Request (DOE DOES N T ssen any fire protection requirements. Or Request (DOE (DOES NOT ssen the structural integrity The Request is: -Granted ❑ Denied (See reverse for appeal information) ❑ Granted (Ratification required) Conditions of Approval: Signatur - --- - Position CHIEF SUI! Date 01 — Z Print Name I NEe I APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse) (Signature, statement of owner or applicant, statement of reasons for appeal and filing fees are required.) CASHIER RECEIPT NUMBER: (ice'\ J onoa 2i �� Forms\modif 08/21/23