Loading...
HomeMy WebLinkAboutXR2023-3520 - Alternative Material & Methods (3)PRODUCT DATA SHEET Sika° MB Solvent Free, Epoxy Moisture Barrier PRODUCT DESCRIPTION Sika® MB is a 2-component, solvent free, low viscosity, epoxy for use under wood flooring products, self leveling underlayments, floating floors and other flooring systems that require protection from subfloor moisture. USES • Moisture barrier to help control moisture propagation in cementitious substrates with a moisture content not exceeding 6 % by Tramex Method, residual moisture Up to 100 % R.H. or 25 Ib/1,000 ft2/24 In (11.4 kg/92.9m 2/24 h) • For substrate consolidation on concrete, cement and gypsum screeds • Adhesion promoter for old and new adhesive residues in conjunction with other Sika® products • Suitable on concrete, cement, self -leveling and gypsum substrates, CSB, plywood, quarry and terrazzo tiles, water-soluble adhesive and cutbacks PRODUCT INFORMATION CHARACTERISTICS / ADVANTAGES • Solvent -free (100 % solids) • Easy roller applied application, low viscosity • Convenient, easy to mix packaging • Shorter construction periods • Excellent penetration and stabilization of the substrate • Reduction of adhesive consumption • Suitable for use on floors with radiant heating Compatible with SikaBonde wood flooring adhesives, Sikae Level products • Can be used below floating floors APPROVALS/STANDARDS • Meets ASTM F 3010 Chemical Base Two component epoxy Packaging 2.64 gal (10 L) pail Color Blue shelf Life 24 months from date of production if stored properly in undamaged sealed containers Storage Conditions Store dry at 50-77 •F (10-25 °C). Protect from moisture. Density 691b/ft3(1.1 kg/1) TECHNICAL INFORMATION Product Data sheet Sika° Ma June 2019, Version 01.04 020512081000000017 1/4 Shore D Hardness 7 days 83 (mixed A&B) (ASTM D-2240) Compressive Strength 7 days 10,000 psi (69 MPa) 73 °F (23 °c) 50 % R.H. Permeability to Water Vapor 0.06 g/m2-24hour-mmHG (ASTM E-96) Service Temperature -40-158 °F (-40-70 °C) APPLICATION INFORMATION Coverage Coverage per pail Moisture barrier 250-300 ft2 (23.2-27.9 m2) Adhesion promoter or 400-450 ft2 (37.2-41.8 mz) surface consolidator (Coverage figures do not include allowance for surface profile and porosity or material waste). Application Recommended Results In Coatings Moisture barrier only min. 1 Mirror like finish Substrate min. 1 Good penetration consolidation only Adhesion promotion min. 1 Mirror like finish only Moisture barrier+ min.2 Mirror like finish substrate consolidation Moisture barrier+ min. 2 Mirror like finish adhesion promotion MUST produce a monolithic, pinhole -free finish with a continuous film. The need for multiple coats is directly related to surface absorption. Pot Ufe 50 `F (10 °C) - 60 minutes 68 -F (20 °C) - 30 minutes 86 -F (30 -C) -15 minutes Cure Time 50 °F (10 °C) 18 hours 73 -F (23 °C) 8 hours 86 7 (30 °C) 6 hours Minimum curing time, prior to walking on primer/or for applying SikaBond` or Sika° Level Application Time Overcoating Application Minimum Maximum Time Window* Sika® MB 8 hours 36 hours (2nd coat) When Silks- MB is left on the substrate for more than the maximum allowable open time, the surface must be mechanically prepared (i.e. sanded) solvent wiped before proceeding. Product Data Sheet Silks- MB June tali. V--sian 01.0, 0203_ 0A10000f00I7 2/4 BUILDING TRUST APPLICATION INSTRUCTIONS SUBSTRATE PREPARATION • Substrate must be clean, dry, sound and homogeneous, free from oils, grease, dust, and loose or friable particles. Paint, laitance, and other poorly adhering contents must be mechanically removed. • Substrate must have an open textured surface to allow Sika® MB to penetrate. (i.e. Blast cleaning, grinding are considered acceptable means to achevie the desired surface profile. Acid and chemical etching are not acceptable). • At least 50 % of the surface area must be cleared of residual adhesive and cutbacks. (i.e. by grinding or mechanical substrate preparation) • Old cutback can contain asbestos which is dangerous for the health so do not grind, sand or blast. Refer to the Resilient Floor Covering Institute's publication "recommended work practice for removal of resilient floor coverings" for instruction. • Minimum substrate compressive strength > 1,160 psi. Tensile Bond strength > 116 psi at the time Sika® MB is applied. • Repair with Sika' Level SkimCoat or SikaQuick' mortar before priming. • The floor must be cleaned with an industrial vacuum prior to installation of the Sika® MB. • On fiber reinforced concrete, fibers should be flamed off the surface prior to application of Sika® MB as a moisture barrier. • Before overall installation begins, Sika' recommends the application of several small test patches to determine primer application requirements and acceptability of final product performance. MIXING • Add one full can of component A to one full can of component B then mix with an electric drill and mixing (Jiffy Mixer type) paddle at a low speed to reduce air entrainment (300-400 rpm). Using a paint stick or similar is not sufficient to mix the primer. • A minimum mixing time of 3 minutes shall be observed; mixing shall continue until a homogeneous mix has been achieved. • Scrape sides of pail with paint stick or paddle to ensure all contents are thoroughly mixed together. • Unmixed material applied to the floor will not cure properly. APPLICATION METHOD / TOOLS Apply Sika® MB uniformly (in 2 directions 90") to the substrate using a medium nap roller, ensuring that a continuous coat is achieved over the entire surface (MUST produce a mirror like finish). Pour contents of pail onto the floor for best working time. Attempting to work from the pail will reduce working time. When used as a moisture barrier and substrate consolidation / adhesion promotor, prepare the Product Data Sheet Sika- MB June 2019, Version 01,04 020511081000000017 3/4 substrate mechanically as in accordance with the guidelines stated in subtitle "Surface Preparation". Apply the first coat at 10 mils Apply the second coat at 15 mils in accordance with the open time*. 2 coats application: Apply the first coat at 75-115 ft2/gal Apply the second coat at 150-225 ft2/gal in accordance with the application time window*. Then follow one of the option: • Option 1: Broadcast to refusal with oven dried silica sand (20/30) on the second coat immediately. Sweep sand once the epoxy is cured. Apply Sika® Level products on cured epoxy. • Option 2: Apply Sika® Level-02 EZ Primer in accordance with the application time window*. When the primer is dry, apply Sika® Level products. *ref. to appliction time in sections above CLEANING OF TOOLS • Clean all tools and application equipment with cleaning solvent (Xylene, MEK are effective). • Hardened/cured material can only be removed mechanically. LIMITATIONS • Proper coverage must be used to achieve moisture barrier properties. • Will not act as a moisture barrier for gypsum screeds. Gypsum based subfloors are very susceptible to excess moisture and will be degraded if exposed to excess moisture from below or above. • Only protects from moisture coming from below the concrete. • Will not prevent hydrostatic pressure. • Must not be applied to a visibly wet substrate. • Does not prevent moisture occurring between the epoxy and the floating floor due to secondary sources of moisture or acclimation, e.g. water condensation. • Is not suitable for use with bonded systems due to possible curing and adhesion problems. • Sika* recommends the use of Sika' Level products on top of it. • Floor covering manufacturer's and Wood flooring manufacturer's recommendations, like room humidity levels and wood acclimation requirements should be strictly followed. • Sika' does not make any standing recommendations as to the structural integrity of old adhesive residues or subflooring materials that are not manufactured by Sika'. • When left on the substrate for more than the maximum allowable open time of 36 hours, prior to placing the adhesive, the surface must be thoroughly cleaned and mechanically prepared (i.e. screened sand) and solvent wiped. Failure to do this, may result in adhesion problems. For detailed instruction contact our Technical Service. When used in conjunction with SikaBond', Sika® MB does not need to be broadcasted with sand. BUILDING TRUST AA BASIS OF PRODUCT DATA LEGAL DISCLAIMER Results may differ based upon statistical variations depending upon mixing methods and equipment, temperature, application methods, test methods, actual site conditions and curing conditions. OTHER RESTRICTIONS See Legal Disclaimer. ENVIRONMENTAL, HEALTH AND SAFETY For further information and advice regarding transportation, handling, storage and disposal of chemical products, user should refer to the actual Safety Data Sheets containing physical, environmental, toxicological and other safety related data. User must read the current actual Safety Data Sheets before using any products. In case of an emergency, call CHEMTREC at 1-800-424-9300, International 703-527-3887. Slka Corporalbn 201 Polito Avenue Lyndhurst, NJ 07071 Phone: i1-800-933-7452 Fax.1-201-933-6225 usa.sikaxom cis'•' � s Product Data Sheet Sika• MB June 2019, Version 01.04 020512081000000017 4/4 Slka Mexican SA de C.V. Carretera Libre Celaya Km. 8.5 Fracc. Industrial Balvanera Corregidora, Queretaro C.P. 76920 Phone: 5244223B5800 Fax: 52 4,12 2250537 • KEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY • FOR PROFESSIONAL USE ONLY Prior to each use of any product of Sika Corporation, its subsidiaries or affiliates ("SIKA"), the user must always read and follow the warnings and instructions on the product's most current product label, Product Data Sheet and Safety Data Sheet which are available at usa.sika.com or by calling SIKA's Technical Service Department at 1-800-933-7452. Nothing contained in any SIKA literature or materials relieves the user of the obligation to read and follow the warnings and instructions for each SIKA product as set forth in the current product label, Product Data Sheet and Safety Data Sheet prior to use of the SIKA product. SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within the products shelf life. User determines suitability of product for intended use and assumes all risks. User's and/or buyer's sole remedy shall be limited to the purchase price or replacement of this product exclusive of any labor costs. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. Sale of SIKA products are subject to the Terms and Conditions of Sale which are available at https://usa.sika.com/en/group/SikaCorp/termsandconditions.htmi or by calling 1-800-933-7452. SikaMB-en-US-106-20191d-4.pdf OD BUILDING TRUST AA SOIL BEARING CAPACITY=1,500 psf``�� (ri`vl- I i (FO#4 DOW 24' LONG DC. (NJ#4 DOWELS 24' LONG @ IS - "AS A CALIFORNIA LICENSED ENGINEER, I HAVE CLASSIFIED THE UNDISTURBED NATIVE SOILS TO BE "silt, sand' AND PER TABLE 1806.2 OF THE 2019 CBC. I HAVE ASSIGNED A FOUNDATION PRESSURE OF 1,50D psT FOR THE DESIGN OF FOUNDATIONS RELATED TO THIS PROJECT'. IF THE BUIL➢ING INSPECTOR SUSPECTS FILL, EXPANSIVE SOIL OR ANY GEOLOGIC INSTABILITY BASED UPON OBSERVATION OF THE FOUNDATION EXCAVATION, A SOILS OR GEOLOGICAL REPORT, AND RE -SUBMITTAL OF PLANS TO PLAN CHECK TO VERIFY THAT THE REPORT RECOMMENDATIONS HAVE BEEN INCORPORATED, MAY BE REQUIRE➢. mw O COMPLY WRH COY OF NEWPORT BEACH CBC 1803.5 NOTE f7, A SOIL COMPACTION SOIL UNDER FOUNDATION SHALL BETO VERIFY RELATIVE COMPACTION OF 905, ANDG CAPACITY OF L500 PSF MINIMUMSN-2 SPECIAL INSPECTION REQUIREMENTS' NOTES 6 DESIGN CRITERIAI -AL MR SHEW WNLS TO BE PLYWOOD -BMW WILLS MifH A META WLIE GREATER THAN 2$50 Pli BH/1L HAVE 3X FOUNMMNi SILL PLATES. U SUDS AND BLOCKS BEOMEEN OANCEM PM . 11V EDGE DI MICE MR RYNOOD BOUNDARY MUNG. STAGGER N4IS IF ML SPACING IS L65 T 2' OC. -ANCHOR BOUTS SIWL INCWDE PLAR WASHERS, A MINIMUM OF 0.229N3'a3- IN SEE BEIWIDI SILL PULE AND NOT R60211.1 (ACCEPTABLE BURNS 4.3.6.4.31 -FASIFMFB AND CONNECTORS TO BE GOLVANIZED FOR PRES6RMATNE OR ffED WOOD COO 2 .9.5.1 -AL OMPHR0KIM WILING B NO_ IMUZF COMMON WNLS. SHEAR WALL NAUNG BWLLL MLIIE COMMON OR GWVANIZEO mm -AL BOLT HOLE3 SMALL BE ORRLED 1/32' TO 1/16' wERSYm. -HOLDOWN CONNECTOR BOU3 IN10 WOOD FFIMING REQUIRE PPPROhD PULE WASHERS. -HOLDOWNS SNALL BE TONRNED JUST Pf TO CO ING THE WNL FRAMING. -ROOFING MATERIAL WEOHf- 5.5 ME -FLOOR UVE LOAD- 40 PSF -ROOF USE LINO= 20 PS -KWIC WINO SEED- 110 MPH -WIND IMPORTANCE FACTOR wx -WIND OOCUPmLY UTEGORY=II -WIND FXPOBUfE- C -WINO VOLOCRY PRESSU E-18.00 ME -CGNR k CUDpNG MR MNE TTY INSPECTOR SHALL BE PRESENT DURING THE DRILLING. CLEANING PLACEMENT OF THE RETROFIT BOLT. DEPUTY INSPECTOR SHALL FURNISH 'ORT TO THE CONTRACTOR, ENGINEER AND THE INSPECTOR. THE REPORT . BE SPECIFIC TO THE SPECIFIC WORK OBSERVED AND THE WORK IS IN RDANCE WITH THE PLANS AND THE MANUFACTURER'S INSTALLATION UCTIONS. SHOULD THE INSPECTED WORK NOT TO BE IN ACCORDANCE THE PLANS OR THE MANUFACTURER'S INSTALLATION INSTRUCTIONS; THE TY INSPECTOR SHALL FURNISH A CORRECTION REPORT TO THE :ACTOR, ENGINEER OF RECORD AND THE BUILDING INSPECTOR. tEASIONS TO THE APPROVED PLANS MUST BE APPROVED BY THE EER OF RECORD AND BUILDING DEPARTMENT BEFORE PROCEEDING WITH CD J c0 aN W w � U W Q W m U N U Uw �~w Q o m xa1 1Y aoo oQ- w z a p (M#4 DOWELS N 1R N M ] ALE S i1R L OC--L..LE ON c- `_ -1 D N)2'-6'SOK12' D _ 24' LONG @ IS_DC, 1 TYP vitE D F- Z s Q L _ _—_ _ � _ p6 J TYP V a T NG WALLS 0 J ® 1 TYP x8 Val'oA-3 060 'osZi EF,1'� N 64 NP N 10' 14 .. 28 . 1 ' E 5 O (W34'z48'x15' w s N PILE N 01•Spa N 9#4 Own LL PROPOSED FOUNDATION PLAN SLAB NOTES- -NEW. 5' SLAB ON GRADE W/#4 0 18" OC. IN BOTH DIRECTIONS, WITH 2' CLEW SAND OVER A 15 MIL STEGO WRAP VAPOR BARRIER WITH ALL LAPS SEALED, UNDERLAIN BY 4 INCH GRAVEL(CAP11LARY BREAK) EXISINC SLAB ON GRADE SHALL COMPLY WITH NBMC 75.02.060 BY INSTALLING A CAPILLARY BREAK SUCH AS SIKA MB - WATER VAPOR BARRIER. PLEASE SEE SHEET A-0.0 FOR PRODUCT DATA SHEET