HomeMy WebLinkAboutGB040084_Correction ListCounty of Orange
Resources & Development Management Department
Building Permits Division
Main Office
300 N. Flower Street
Santa Ana, CA 92702-4048
Grading Plan Check Corrections
Corrections shall be made on the tracings and three(3) new sets of plans shall be submitted. If you make changes to the
plan other than or in addition to what Plan Check has requested, yellow highlight the changes on one set of the re-submitted
plans.
Return the original check print with corrected plans. Payment of a new plan check deposit may be required for all plans
on which no action is taken by the applicant for a period of 180 days. Applications for which no permit is issued within
180 days following the date of submittal shall expire by limitation, and shall be discarded.
Project Number:GB040084
Submittal Date:Jun 11, 2004
CBC Edition: 2000
Plan Check Date: 6/29/2004 9:00 AM
Description:precise for sfd
and attached garage
(retaining walls
by separate permit)
Job Address
9 PELICANS DR
NEWPORT COAST, CA
Owner Address
Scott and Paula Bower
12 Cavailion
Irvine Coast CA92652
Current - 1st Plan Check
Architect of Record
ERIC TRABERT & ASSOCIATES
20351 Irvine, Suite #1
Santa Ana Heights CA92707
714-641-1505
Engineer of Record
ESI/FME Inc.structural Engineers
1921 East Carnegie Ave
Suite #3J
Santa Ana CA92705
714-261-1811
Plan Checked By
Michael Fisher
Michael.Fisher@pdsd.ocgov.com
714-834-6156
Contact Address
Elizabeth Innes
20351 Irvine Ave.
Suite One
Santa Ana Heights CA92707
714-641-1505
714-641-1091 FAX
etrabert1@aol.com
Page 1 of 5
GB040084
GENERAL INFORMATION
Please provide 24-hour notice to your plan checker, prior to obtaining the grading Permit.Return the original check
print with corrected plans. Payment of a new plan check deposit may be required for all plans on which the applicant
takes no action for a period of 180 days. Applications for which no permit is issued within 180 days following
date of submittal shall expire by limitation, and shall be discarded.
SUBMITTALS, FEES, BOND, INSURANCE AND ISSUANCE
Provide three (3) complete sets of corrected plans. Provide minimum 40-scale plan for precise grading. The maximum
size shall be 36" x 42". All sheets shall be uniform size. Plans will not be rechecked at the counter. Allow
one week for recheck.
Plan check and inspection deposit amounts will be calculated by the plan checker based on earthwork quantities
or drainage improvements, whichever is greater. The engineer shall provide this information.
Surety is required in the amount of $ _________. Surety may be posted in one of the following forms:
Bond
Certificate of Deposit
Letter of Credit
Cash or Cashier s Check
Personal/Company checks cannot be accepted. County approved forms for the various types of surety are available
upon request at the Grading Counter, Station 4, Room 122. Please note all signatures must be notarized.
Provide verification of contractor's coverage for Workman's Compensation insurance. If owner is doing work and
will not employ other workers, owner must sign exemption statement.
Owner or authorized agent and/or contractor must sign the permit at the time of issuance.
Authorized agent must have a notarized statement from the owner authorizing the agent to act on behalf of the owner.
The permittee and the entity providing the surety must be the same i.e., owner, developer or contractor.
Page 2 of 5 6/29/2004 9:00 AM
GB040084
Grading Plan Check Corrections
Sheet Comments
General
1 B) Show site acreage and earthwork quantities on plans:
1.1 Export_______yds.
2 C) Each sheet of all plan sets must be stamped and signed by the Civil Engineer
or Architect of Record for the project.
3 E) Submit an itemized summary of the unit and total cost of all drainage devices,
grading, paving, and erosion control. (Submitted with initial plan check).
4 F) Show on Plans:
4.1 Grading Legend
4.2 Grading Limits and Off-Site Grading Limits
4.3 Permit Limits
4.4 Property Lines (label all property lines with P.L. symbols).
5 G) A notarized letter of permission from adjacent property owner(s) is required
for slope encroachment or other off-site grading or work . Include off-site legal
description and Assessor´s Parcel Number.
6 H) Show location of retaining walls on grading plan plus top of wall elevations,
adjacent finished surface elevations, top of footing elevations, provide a cross
section detail showing subdrain design, indicate drainage outlet for all retaining
walls. Retaining walls are not a part of the grading permit. Submit for separate
building permits; show connection of subdrain to storm drain. Note on plans.
7 I) Show all cut/fill transitions and daylight lines.
8 N) Show all easements, (i.e. drainage, utilities, etc.).
9 O) Extend existing contours or spot elevations to reflect off-site areas and identify
drainage patterns, min. of 15 ft beyond P.L.s.
10 Q) Approved erosion control measures are to be installed and functional during
the rainy season from October 15 to April 15. Justify design with hydrology and
hydraulic calculations. Submit three (3) copies of an erosion control plan and a
cost summary of erosion control facilities. If proposed grading will take place
after April 15, continue to show erosion control plans. Grading may extend into
the next rainy season.
Page 3 of 5 6/29/2004 9:00 AM = Indicates line item not Cleared.
GB040084
Grading Plan Check Corrections
Sheet Comments
11 S) Show on title sheet of plans name, address, and telephone number of:
11.1 Soil Engineer
11.2 Engineering Geologist
12 W) Additional comments may be made after field verification that the plans and
soils report accurately reflects existing conditions.
13 Z) Show location of sump pump on the grading plan. (Provide Brochure). An electrical
and plumbing permit must be obtained from the Building Permits Division (if applicable).
Drainage Instructions
14 B) Submit a hydrology study and/or hydraulic calculations for this project.
15 E) Show typical detail for the 12" high by 4´ wide berm, which is required at
top of slopes.
16 H) Maximum gradient for sheet flow is 10%.
17 I) Minimum, acceptable gradients:
17.1 Earth 1.00%
18 L) Drainage over a manufactured slope is not permitted except in approved devices.
19 M) Show limits of roof gutters and location of downspouts (if discharged onto
A.C. paving or onto a finished grade, a P.C.C. splash block is required).
20 Q) Show the approved non-erosive device where concentrated drainage exceeds 4%
gradient. Use concrete, gunite, or other approved materials.
21 T) Show detail and locations of extra depth footings.
22 V) Show flow line elevations of all swales and other drainage devices.
23 W) Show retaining wall subdrain details with disposal points, flow line elevations
and pipe material.
24 X) Show typical section of driveway and pavement section. Include type of surfacing
material.
Page 4 of 5 6/29/2004 9:00 AM = Indicates line item not Cleared.
GB040084
Grading Plan Check Corrections
Sheet Comments
25 Y) Show typical section of hardscape. Include type of surfacing material.
Slopes
26 H) Show top and toe of cut and fill slopes.
Geotechnical
27 A) Obtain approval of soils and geology report by County Geotechnical staff. Reports
have been forwarded for their review.
Page 5 of 5 6/29/2004 9:00 AM = Indicates line item not Cleared.