HomeMy WebLinkAboutH2019-0825 - MiscPROJECT SUMMARY
Project Name:
Address:
City, State, Zip:
Building Department:
Permit Number:
Building Energy Code:
COSTELLO,D
366 Villa Point Or
Newport Beach, CA 92660
Newport Beach, City of
On File
2019 Standards
HERS VERIFIABLE
MEASURES
ENERGY CODE
COMPLIANCE
Scan to Validate
COMPLETE
COMPLETE NJ
CERTIFICATE OF COMPLIANCE (CF1R)
DATE DOCUMENT TITLE
REGISTRATION NUMBER
STATUS
05/27/2022 CF1 R-ALT-02-E Residential HVAC Alterations
422-AO20079419A-000-000-0000000-0000
D06 changed from "S" to "S.5"
D10 changed from "14" to "l 5"
CERTIFICATE OF INSTALLATION
(CF2R)
DATE DOCUMENT TITLE
REGISTRATION NUMBER
STATUS
COSTELLO,D
05/27/2022 CF2R-MCH-01b-E HVAC, Ducts and Fans
422-AO20079419A-001-001-M01001A-0000
rA
COSTELLO, D (CONDO)
05/27/2022 CF2R-MCH-20e-H Duct Leakage
422-A020079419A-001-001-M20002A-0000
El
CERTIFICATE OF VERIFICATION
(CF3R)
DATE DOCUMENT TITLE
COSTELLO, D (CONDO)
05/27/2022 CF3R-MCH-20e-H Duct Leakage
REGISTRATION NUMBER STATUS
422-AO20079419A-001-001-M20002A-
M20A 19
NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using
information that has been uploaded to that registration platform by third parties that are not affiliated or related to
CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the
information contained in this certificate.
Page 1 of 1
Address:
366 Villa Point Dr
Contractor:
Just Right Services
City/State/Zp:
Newport Beach, CA 92660
HERS Company:
Reliance Energy Services
Building Department:
Newport Beach, City of
HERS Rater:
Jason Soco"O
Permit Number:
On File
Verification Date:
5/27/2022
System Name:
System 1
Project Type:
2019 Alteration
YOUR HOME PERFORMANCE RESULTS: -®
Your home's HVAC system has been independently Inspected and verified by a certified California HERS Rater. The reported results indicate this
home meets the rigorous energy efficiency requirements set forth by the Cationnia Energy Commission. These results have been registered in the
CHEERS Registry.
/
470 cfm
DUCT LEAKAGE
Air leakage from the HVAC system ducting.
Accepted result is 150 clot or less.
SYSTEM AIR FLOW
Total airflow generated by the HVAC system.
Accepted result is 400 cfm or greater.
HEATING SYSTEM
Manufacturer
Model:
Serial:
Efficiency:
FIRST CO
30HXO-240
2110-21988
8.5 HSPF
FAN EFFICIENCY
Efficiency of the HVAC system fan.
Accepted result is 300.00 watt/cfm or less.
H
REFRIGERANT CHARGE
Measurement of adequate refrigerant level in the AC system.
Accepted range from 10 to 22'F.
COOLING OLING SYSTEM
Manufacturer: AMERICAN STANDARD
Model: 4A6H4030G10WAB
Serial:
Efficiency:
22136L77FF
15 SEER
REGISTRATION NUMBER:422-AO20079419A-001-001-MO1001A-0000
NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using Information that has
been uploaded to that registration platform by third parties that are not affiliated or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this certificate.