Loading...
HomeMy WebLinkAbout2.0_Barnard Residence_PA2023-0018 CITY OF NEWPORT BEACH PLANNING COMMISSION STAFF REPORT October 3, 2024 Agenda Item No. 2 SUBJECT: Barnard Residence (PA2023-0018) ▪ Coastal Development Permit ▪ Variance SITE LOCATION: 3907 Seashore Drive APPLICANT: Ritner Group INC. OWNER: The Amended and Restated Kenneth A. Barnard and Stephanie S. Barnard Revocable Living Trust PLANNER: Oscar Orozco, Assistant Planner 949-644-3219, oorozco@newportbeachca.gov PROJECT SUMMARY A request for a coastal development permit to demolish an existing two-unit dwelling and construct a new 2,318-square-foot, three-story, two-unit dwelling with an attached 444- square-foot, two-car garage and two carport spaces in the VE Special Flood Hazard Area (VE Flood Zone). Additionally, the applicant requests a variance from Title 20 (Planning and Zoning) and Title 21 (Local Coastal Program Implementation Plan) of the Newport Beach Municipal Code (NBMC) to construct three exterior entry stairs, one within the front setback facing West Ocean Front and two entirely within interior side setbacks. The front stairs are approximately 5 feet, 4 inches in height, measured to the highest guardrail and the side stairs are approximately 7 feet, 9 inches in height, measured to the highest guardrail. A variance is required because the NBMC restricts stairs, platforms, and landings within the side setback to 18 inches maximum, measured from existing grade, and restricts fences, hedges, and walls (including guardrails and handrails) to 6 feet maximum, measured from existing grade. Further, the NBMC restricts the height of fences, hedges, and walls (including guardrails and handrails) within the front setback to 42 inches maximum, measured from existing grade. The project complies with all other development standards and no other deviations are requested. RECOMMENDATION 1) Conduct a public hearing; 2) Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, because it has no potential to have a significant effect on the environment; and 1 IN T E N T I O N A L L Y B L A N K P A G E 2 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 2 3)Adopt Resolution No. PC2024-021, approving the Coastal Development Permit and Variance filed as PA2023-0018 (Attachment No. PC 1). VICINITY MAP GENERAL PLAN ZONING LOCATION GENERAL PLAN ZONING CURRENT USE ON-SITE Two-Unit Residential (RT) Two-Unit Residential (R-2) Two-unit residential NORTH RT R-2 Two-unit residential SOUTH RT R-2 Single- and two-unit residential EAST RT R-2 Single- and two-unit residential WEST Parks and Recreation (PR) Parks and Recreation (PR) Beach Subject Property 3 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 3 INTRODUCTION Project Setting The subject property is a 2,093-square-foot beachfront lot located on the westerly side of Seashore Drive, between 39th and 40th Streets. The site is currently developed with an existing 3,640-square-foot, three-story duplex with an attached two-car garage. The property abuts the public beach. The site includes an approximately 9.5-foot-deep patio, which is permitted to encroach onto the public beach by the Oceanfront Encroachment Policy (Appendix C) of the Local Coastal Program (LCP) Implementation Plan. Figure 1: Aerial view of the subject property abutting the beach Background VE Special Flood Hazard Area The property is located within the VE Flood Zone (15), which is a Flood Zone designated by the Federal Emergency Management Agency (FEMA) Flood Insurance Rate Maps (FIRMs) affecting 139 ocean fronting properties between 28th Street and 48th Street (Figure 2 below). The FIRMs became effective March 21, 2019. Subject Property 4 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 4 Figure 2: Properties within the VE Flood Zones New development within the VE Flood Zone (15) is required to meet FEMA design criteria and the City’s Building Code, which require the first floor of the dwelling to be elevated approximately 3 to 5 feet above the ground. Specifically, in the VE Flood Zone, the first floor of the dwelling is required to be at or above the Base Flood Elevation (BFE) of 15 feet based on the North American Vertical Datum of 1988 (NAVD 88), and the City requires an additional 1 foot of freeboard to the bottom of the lowest horizontal structural member. Therefore, the lowest horizontal structural member must be at an elevation of 16 feet NAVD 88. Including the floor system, the finished floor of new residential dwellings in the VE Flood Zone is typically at an elevation of 17.5 feet NAVD 88. The FEMA construction design criteria requires that new developments utilize pilings, posts, piers, or columns to raise the main dwelling and maintain an open foundation free of obstructions for those areas located below the BFE as shown in Figure 3 below. Garages are allowed to be located below the BFE, provided they are constructed with breakaway walls per the National Flood Insurance Program (NFIP). Additionally, raising the residential structure requires an elevated stair system to access the dwelling; Condition of Approval No. 28 is included to ensure that the stairs are an open design and constructed of flood damage resistant material per the NFIP. Subject Property 5 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 5 Figure 3: Conceptual design for a raised structure with an open foundation per FEMA construction design criteria In the event of wave action, these structures are designed and engineered to allow water to flow below the elevated floor system without damaging the foundation or creating substantial debris. Figure 4 on the following page provides an example of an elevated foundation. 6 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 6 Figure 4: Example of a raised foundation on piers/piles. Challenges for Development in the VE Flood Zone Compliance with the new VE Flood Zone design criteria presents several challenges for new residential development to also meet the requirements of Title 20 (Planning and Zoning) and Title 21 (Local Coastal Program Implementation Plan) of the NBMC. Specifically, the VE Flood Zone design criteria significantly limit the means of access to the dwelling. For example, the NBMC allows stairs, landings, platforms, steps, and similar features to encroach into the side setback up to 18 inches from existing grade. Similarly, the NBMC allows fences, hedges, and walls, including guardrails and handrails, to encroach into the side setback up to 6 feet from existing grade. However, for new residential dwellings in the VE Flood Zone, the existing grade may be 5 or more feet below the new finished floor, making access impossible within the side setback without a variance for the maximum height of accessory structures. The City is in the process of amending the NBMC to remedy the challenges related to access to the dwelling. 7 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 7 Pending Zoning Code and LCP Amendments On March 26, 2019, the City Council adopted Resolution No. 2019-31 initiating an amendment to Title 20 (Planning and Zoning) and Title 21 (Local Coastal Program Implementation Plan) of the NBMC to modify the setback encroachment regulations for residential properties in the VE Flood Zone. On June 27, 2023, the City Council adopted Ordinance No. 2023-10 to amend Title 20 (Planning and Zoning) and approved Resolution No. 2023-37 authorizing the submittal of a Local Coastal Program Amendment (LCPA) to the California Coastal Commission (CCC) for approval to amend Title 21 (Local Coastal Program Implementation Plan). The amendments will create a Special Food Hazard Area (VE) Overlay Zoning District to modify certain development standards for properties in the VE Flood Zone. The VE Overlay District would allow for the construction of raised patios, steps, landings, platforms, terraces, stairs, guardrails, handrails, and similar features for access to exceed the height limits for accessory structures within side, rear, and front setbacks, subject to certain limitations. The LCPA was deemed complete on April 15, 2024, and will be scheduled for a future hearing date for consideration by the CCC. Until the CCC approves the LCPA, the VE Overlay District will not be effective in Title 20 (Planning and Zoning) or Title 21 (Local Coastal Program Implementation Plan) and a variance is necessary to authorize deviations to setback standards. Project Description The applicant proposes to demolish an existing two-unit dwelling and construct a new 2,318-square-foot, three story, two-unit dwelling with an attached 444 square-foot two-car garage and two carport spaces in the VE Flood Zone. The proposed residence features a contemporary design, which utilizes split-level living spaces, balconies and decks, and a third floor, which is stepped back to reduce bulk and mass. The proposed structure includes a raised foundation at 17.25 feet NAVD 88, which is supported by caissons to meet the minimum finished floor requirements of the VE Flood Zone. The structures below the required base flood elevation are designed as breakaway walls or are open construction to allow water to flow through them. They are also designed to be consistent with ASCE 24 (American Society of Civil Engineers) Section 4.5.12. The project includes hardscape, walls, and drainage facilities. DISCUSSION Analysis General Plan, Local Coastal Plan, and Zoning Code 8 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 8 The site is categorized as Two-Unit Residential (RT) by the General Plan Land Use Element and Two Unit Residential– 30.0-39.9 DU/AC (RT-E) by the Coastal Land Use Plan (CLUP). It is located within the Two-Unit Residential (R-2) Zoning District and Coastal Zoning District. The two-unit dwelling is a permitted use within these designations. With the exception of the requested deviations for maximum stair and guardrail height in the side setback areas, the proposed residence complies with all other applicable development standards of the R-2 Zoning and Coastal Zoning Districts, as illustrated in Table 1 below: Table 1: Zoning and Coastal Zoning Development Standards Development Feature Required Proposed Setbacks (min.) Front (West Ocean Front) Rear (Street) Left Side (West) Right Side (East) 5 feet 0 feet 3 feet 3 feet 5 feet1 7 inches 3 feet 3 feet Height (max.) Flat Roof Sloped Roof 24 feet 29 feet 24 feet 29 feet Floor Area Limit (max.) 2,877 sq. feet 2,762 sq. feet Third Floor Area (max.) No Maximum 262 sq. ft. Parking (min.) 2 spaces per unit; 1 in a garage and 1 covered or in a garage 2 spaces in a garage and 2 spaced covered 3rd Floor Stepbacks 15 feet 15 feet 1 The project also includes balconies that are permitted to encroach 3 feet into the front setback that fronts the public beach pursuant to Sections 20.30.110(D)(5) and 21.30.110(D)(5) (Setback Regulations and Exceptions – Balconies Abutting East Ocean Front and West Ocean Front) Title 20 - Variance Findings A variance is requested for two entry stairs to exceed the maximum height limit in the side setbacks and one entry stair to exceed the maximum height limit in the front setback. A variance is a request to waive or modify certain standards when, because of special circumstances applicable to the property, including location, shape, size, surroundings, topography, or other physical features, the strict application of the development standards otherwise applicable to the property denies the property owner privileges enjoyed by other property owners in the vicinity and in the same zoning district. Section 20.52.090(F) (Variances, Findings and Decision) of the Zoning Code requires the Planning Commission to make the following findings before approving a variance: A. There are special or unique circumstances or conditions applicable to the subject property (e.g., location, shape, size, surroundings, topography, or other physical 9 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 9 features) that do not apply generally to other properties in the vicinity under an identical zoning classification; B. Strict compliance with Zoning Code requirements would deprive the subject property of privileges enjoyed by other properties in the vicinity and under an identical zoning classification; C. Granting of the Variance is necessary for the preservation and enjoyment of substantial property rights of the applicant; D. Granting of the Variance will not constitute a grant of special privilege inconsistent with the limitations on other properties in the vicinity and in the same zoning district; E. Granting of the Variance will not be detrimental to the harmonious and orderly growth of the City, or endanger, jeopardize, or otherwise constitute a hazard to the public convenience, health, interest, safety, or general welfare of persons residing or working in the neighborhood; and F. Granting of the Variance will not be in conflict with the intent and purpose of this Section, this Zoning Code, the General Plan, or any applicable specific plan. Entry Stairs The project includes two entry stairs within the side setback to provide primary access to the dwelling units. There is an additional set of stairs in the front setback to provide access from the dwelling to the beach and ocean beyond. The three stairs are shown below in Figure 5. Due to the VE Zone flood hazard standards requiring a raised finished floor, stairs are necessary to reach the finished floor from the lower existing grade. Figure 5: Side East Elevation of Entry Stairs Side Entry Stairs Front Entry Stairs 10 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 10 Figure 6: Side West Elevation of Entry Stairs Side Setback The existing grade within the side setback is approximately 12.07 feet NAVD 88, which is 5.18 feet lower than the required 17.25-foot finished floor of the two-unit dwelling. The proposed top of landing for the side entry stairs is approximately 4 feet and 4 inches above existing grade, which exceeds the maximum 18-inch height requirements for steps in the side setback. The required guardrail exceeds the height of the platform by 42- inches, the minimum height required per building code, for a total height of 7 feet 9 inches above existing grade. This height exceeds the 6-foot maximum height for fences, hedges, and walls, within side setbacks. Condition of Approval no. 8 requires that 40% of the guardrails are open throughout to help ensure light and air are not blocked by the guardrail. Properties outside of the VE flood zone are typically able to accommodate an entryway in the side setback without the necessity of stairs. Strict compliance with the Zoning Code would require the dwelling’s main entryway stairs be relocated into the interior of the residence thereby reducing the amount of livable area on a modest-sized lot. Furthermore, the intent of the Zoning Code is to prevent the alteration of topography within side setback areas, also known as raising the grade, to be significantly higher than the existing grade. A raised grade within the side setback area can create privacy issues with neighboring properties. This project does not create a raised side yard that encourages congregation, rather the stairs provide access to the dwelling. Finally, the footprint of the entryway stairs is relatively small compared to the overall length of the side setback. The Side Entry Stairs 11 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 11 entry stair along the south side setback occupies 17 lineal feet within the setback, or 22% of the setback. The entry stair along the north side setback occupies 13 feet 10 inches within the setback or 17% of the setback. Front Setback The project contains an additional set of stairs in the front setback abutting the beach. These stairs run parallel with the front property line and are intended to provide direct access from the residence to the beach below. The existing patio grade is 14.72 feet NAVD 88, 2.53 feet lower than the required 17.25-foot NAVD 88 finished floor of the two- unit dwelling. The guardrails, which are the tallest element of the stairs are a maximum height of 5 feet, 4 inches above the existing grade. Neighboring properties, as well as the existing property, include existing ocean front patios which are directly accessible from the residence (Figure 6). Direct access from the residence to the patio is necessary for enjoyment of ocean front property. Figure 7: Existing Oceanfront Patios Section 20.30.040 (Fences, Hedges, Walls, and Retaining Walls) of the NBMC permits accessory stairs, including required guardrails, within the front setback to a maximum height of 42-inches above existing grade. Compliant stairs with guardrail are infeasible 12 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 12 due to the VE Flood Zone created condition of a high finished-floor and a low existing patio grade. Like the side stairs, the front stairs are to be constructed with open cable railing to minimize visual impacts. Coastal Development Permit Findings The subject property is located within the Coastal Zone and, therefore, the proposed project requires a coastal development permit. Per Section 21.52.015(F) of NBMC, the required findings to approve a coastal development permit are as follows: A. Conforms to all applicable sections of the certified Local Coastal Program; and B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. Land Use and Development Standards The proposed two-unit dwelling is consistent with the Two Unit Residential Coastal Land Use and Coastal Zoning District. With exception of the requested side setback encroachments, the proposed structure complies with all applicable residential development standards, including floor area limitation, setbacks, height, and parking. The proposed deviations to the maximum stair and guardrail heights within the side setback comply with Section 21.52.090 (Relief from Implementation Plan Development Standards) of the NBMC, which allows for a waiver or modification of certain standards of the Implementation Plan because of special circumstances. Coastal Hazards Since the subject property abuts the ocean, a coastal hazards report was provided by the Applicant. The report, prepared by GeoSoils, Inc., dated November 9, 2022, concludes that the project will be reasonably safe from wave runup, overtopping, and future sea level rise. The estimates assume an approximate 3.2-foot increase from sea level rise over the next 75 years (i.e. the life of the structure). The maximum water elevation is 7.7 feet NAVD 88, therefore the future sea level is estimated to reach approximately 10.9 feet NAVD 88 (the likely range for sea level rise over 75-year design life of the structure based on low risk aversion estimates for sea level rise provided by the State of California, Sea Level Rise Guidance: 2018 Update). Additionally, the maximum water elevation using the medium-high risk aversion estimate (0.5% probability) is 13.7 feet NAVD 88. The finished floor elevation of the first floor of the proposed structure is approximately 17.25 feet NAVD 88, which complies with the minimum 9.0-foot NAVD 88 elevation standard for new structures and exceeds the minimum requirements for future sea level rise (10.9 feet and 13.7 feet NAVD 88). The project will be reviewed for compliance with building code and FEMA standards prior to issuance of a building permit. As previously stated, the VE Flood Zone mapped at the 13 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 13 site requires a base flood elevation (BFE) of 15 feet NAVD 88, and the City requires an additional one foot of freeboard to the bottom of the lowest horizontal structural member. Therefore, the project has been designed with a raised finished floor of 17.5 feet NAVD 88 with a pile foundation to withstand potential wave overtopping in compliance with the FEMA VE Flood Zone standards. Public Views and Access The property is not located adjacent to a coastal viewpoint as identified in the Coastal Land Use Plan. The nearest coastal viewpoint is Newport Island Park and is not visible from the site. The Property is located adjacent to Seashore Drive, where intermittent views of the beach are provided at intersections with street ends. As currently developed, the existing property and other residences along Seashore Drive impede views of the ocean from Seashore Drive and provide very limited opportunities to see the beach through side setbacks. The property is located mid-block, and existing views of the beach are available along the 39th and 40th Street ends. The project would not block any existing views through the project site, as there are no existing views through the site. Additionally, the proposed two-unit dwelling complies with all applicable Title 21 (Local Coastal Program Implementation Plan) development standards and maintains a building footprint consistent with the expected neighborhood pattern of development. Most existing homes in the neighborhood are not yet built on a raised slab, per the FEMA design guidelines and the City’s Building Code. This could make the project appear taller than adjacent residences until future development occurs and neighboring properties are also built on raised slabs. Lateral access is available on the beach in front of the property and along the West Ocean Front Alley to the rear of the property. Vertical access to the beach is available at the 39th Street end and 40th Street end from Balboa Boulevard. The project does not involve the removal or creation of additional street parking spaces. The project design does not include any unique features in the rear of the property that could obstruct access or create hazards for the motorists or pedestrians on Seashore Drive. The carport posts are setback approximately two feet from the property line, which would allow the residents additional visibility to the bike path and street as they enter and exit the garage. Scenic and Visual Quality Protection The property is located between the first public roadway and paralleling the ocean, therefore, NBMC Section 21.30.100 (Scenic and Visual Quality Protection) is applicable. City staff has conducted an initial evaluation of the project site and determined that the proposed development does not have the potential to significantly impact a public view or a viewshed, or the scenic and visual qualities of the coastal zone due to the fact that it is in-line development located in the middle of the block. The project will replace an existing two-unit dwelling with a new two-unit dwelling that complies with applicable development standards. The project also complies with the City’s Residential Development Standards and Design Criteria that restrict the location of third floors. Although not required, the project proposes a relatively small third floor totaling 262 square feet. The third floors accommodate a family 14 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 14 room, bedroom, bathroom, and covered balcony, which complies with the additional 15-foot stepback standards from the front and rear setback lines. Compliance with third floor location standards minimize the appearance of bulk and scale from the adjacent beach, neighboring properties, and street. Relief from Implementation Plan Development Standards Findings Per Section 21.52.090 (Relief from Implementation Plan Development Standards) of the NBMC, the Planning Commission may approve a waiver to a development standard of the Implementation Plan only after making all the following findings: A. Whether or not the development is consistent with the certified Local Coastal Program to the maximum extent feasible; and B. Whether or not there are feasible alternatives that would provide greater consistency with the certified Local Coastal Program and/or that are more protective of coastal resources. C. The granting of the variance is necessary due to special circumstances applicable to the property, including location, shape, size, surroundings, topography, and/or other physical features, the strict application of the development standards otherwise applicable to the property denies the property owner privileges enjoyed by other property owners in the vicinity and in the same coastal zoning district; and D. The modification or variance complies with the findings required to approve a coastal development permit in Section 21.52.015(F); E. The modification or variance will not result in development that blocks or significantly impedes public access to and along the sea or shoreline and to coastal parks, trails, or coastal bluffs; F. The modification or variance will not result in development that blocks or significantly impairs public views to and along the sea or shoreline or to coastal bluffs and other scenic coastal areas; G. The modification or variance will not result in development that has an adverse effect, either individually or cumulatively, on coastal resources, including wetlands, sensitive habitat, vegetation, or wildlife species; and H. The granting of the modification or variance will not be contrary to, or in conflict with, the purpose of this Implementation Plan, nor to the applicable policies of the certified Local Coastal Program. As previously discussed, the proposed development is consistent with the certified Local Coastal Program to the maximum extent possible without depriving the applicant of access into the two-unit dwelling. Staff has analyzed the alternatives of the variance and believes that the proposed project is necessary for a viable project while it does not cause a detriment to the surrounding neighborhood, public views, or public access. An alternative to the side yard entry stairs is to have the entrance door at the side yard grade level and to design a stair system within the buildable area. Stairs within the buildable area count as floor area but reduce the opportunity for practical living areas 15 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 15 such as living rooms and bedrooms on narrow lots. The proposed project already has difficult design constraints due to being located within the VE Flood Zone. Interior stairs would not provide greater consistency with the LCP and are not more protective of coastal resources. Designing a separate entrance on each side of the two-unit dwelling that is within the buildable area is not reasonable. The lot is 25 feet wide with 3-foot side setbacks on each side, leaving a 19-foot-wide buildable width. If each entrance is at least 3 feet deep on each side, that would leave a width of 13 feet for living area. Thus, the lot is not wide enough to allow for separate entrances for both the dwelling units. Therefore, the side yard entry is the most feasible means of entry for the dwelling units. Summary and Alternatives In conclusion, the project will allow the new construction of a two-unit dwelling that is consistent with the Title 20 and Title 21 amendments (VE Overlay District) that have been approved by the City Council and pending review with the CCC. The project is designed to be consistent with the FEMA design criteria and the variance will allow the dwellings to have entry stair access in the side setback up to the raised foundation as required. Neighboring properties outside of the VE Flood Zone are not subject to the same requirements and these design hardships are the basis for findings of the variance. Additionally, the project is consistent with the Coastal Land Use and Zoning District, aside from the side setback encroachments. Staff believes the findings for approval can be made to support the proposed project and the facts in support of the required findings are presented in the draft Resolution (Attachment No. PC 1). The following alternatives are available to the Planning Commission should they feel the facts are not in evidence of support for the proposed application: 1. The Planning Commission may suggest an alternative design to reduce the number of entry stairs that are necessary to alleviate concerns. If the changes are substantial, the item should be continued to a future meeting to allow redesign of the project; or 2. If the Planning Commission does not believe the facts in support of finding can be made, the Planning Commission may deny the application request. Environmental Review This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. 16 Barnard Residence (PA2023-0018) Planning Commission, October 3, 2024 Page 16 Class 3 exempts the construction of limited numbers of new, small structures, including up to three single-family dwellings or up to six dwelling units within multi-unit structures in urbanized areas. The Project includes demolition of an existing two-unit dwelling and construction a new two-unit dwelling. The exceptions to this categorical exemption under Section 15300.2 of the CEQA Guidelines are not applicable. The project location does not impact an environmental resource of hazardous or critical concern, does not result in cumulative impacts, does not have a significant effect on the environment due to unusual circumstances, does not damage scenic resources within a state scenic highway, is not a hazardous waste site, and is not identified as a historical resource. Public Notice Notice of this hearing was published in the Daily Pilot, mailed to all owners of property and residential occupants within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways) including the applicant and posted on the subject property at least 10 days before the scheduled meeting, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. Prepared by: Submitted by: _________________________ Oscar Orozco Assistant Planner ATTACHMENTS PC 1 Draft Resolution with Findings and Conditions PC 2 Project Description and Justification Letter PC 3 Project Plans 17 IN T E N T I O N A L L Y B L A N K P A G E 18 Attachment No. PC 1 Draft Resolution with Findings and Conditions 19 IN T E N T I O N A L L Y B L A N K P A G E 20 RESOLUTION NO. PC2024-021 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF NEWPORT BEACH, CALIFORNIA, APPROVING A COASTAL DEVELOPMENT PERMIT AND VARIANCE TO ALLOW THE DEMOLITION OF AN EXISTING TWO-UNIT DWELLING AND CONSTRUCTION OF A TWO-UNIT DWELLING, ATTACHED GARAGE, AND CARPORT FOR THE PROPERTY LOCATED AT 3907 SEASHORE DRIVE (PA2023-0018) THE PLANNING COMMISSION OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Ritner Group Inc. (“Applicant”), on behalf of Kenneth A. Barnard and Stephanie S. Barnard, Trustees of The Amended and Restated Kenneth A. Barnard and Stephanie S. Barnard Revocable Living Trust, Dated December 29, 2005 (“Owner”), concerning property located at 3907 Seashore Drive, and legally described as Lot 4 of Block 39, Third Addition to Newport Beach Tract, in the city of Newport Beach, County of Orange, State of California, as per map recorded in Book 3, page 31 of Miscellaneous Maps, in the Office of the County Recorder of said county (“Property”). 2. The Applicant requests a coastal development permit to demolish an existing two-unit dwelling and construct a new 2,318-square-foot, three story, two-unit dwelling with an attached 444-square-foot two-car garage and two carport spaces in the VE Special Flood Hazard Area (“VE Flood Zone”). Additionally, the Applicant requests a variance to construct three exterior entry stairs, one within the front setback facing West Ocean Front and two entirely within interior side setbacks. The front stairs are approximately 5 feet, 4 inches in height, measured to the highest guardrail, where fences, hedges, and walls are limited to 24 inches in height (including guardrails and handrails) from existing grade. The side stairs are approximately 7 feet, 9 inches in height, measured to the highest guardrail where stairs, platforms, and landings are limited to 18 inches in height and fences, hedges, and walls (including guardrails and handrails) are limited to 6 feet in height, measured from existing grade (“Project”). The project complies with all other development standards and no other deviations are requested. 3. The Property is categorized as Two-Unit Residential (RT) by the General Plan Land Use Element and is located within the Two-Unit Residential (R-2) Zoning District. 4. The Property is located within the Coastal Zone. The Coastal Land Use Plan category is Two-Unit Residential - 30.0 – 39.9 DU/AC (RT-E) and the Coastal Zoning District is Two Unit Residential (R-2). 5. The City Council adopted Resolution No. 2019-31 on March 26, 2019, initiating an amendment to Title 20 (Planning and Zoning) (“Title 20”) and Title 21 (Local Coastal Program Implementation Plan) (“Title 21”) of the Newport Beach Municipal Code 21 Planning Commission Resolution No. PC2024-021 Page 2 of 20 (“NBMC”) to modify the setback encroachment regulations for residential properties in the VE Flood Hazard Area. 6. The City Council adopted Ordinance No. 2023-10 on June 27, 2023, to amend Title 20 to create a Special Flood Hazard Area (VE) Overlay Zoning District to modify certain development standards for properties subject to special flood hazards as identified by the Federal Emergency Management Agency (“FEMA”) in the Flood Insurance Study (“FIS”) for Orange County, California and Incorporated Area with accompanying FEMA Flood Insurance Rate Maps (“FIRM”). The VE Overlay District allows for the construction of raised patios, steps, landings, platforms, terraces, stairs, guardrails, handrails, and similar features for access to exceed the height limits for accessory structures within side, rear, and front setbacks, subject to certain limitations. 7. The City Council also approved Resolution No. 2023-37 on June 27, 2023, to authorize staff to submit a Local Coastal Program Amendment (“LCPA”) to amend Title 21 to create the Special Flood Hazard Area (VE) Overlay District to modify certain development standards for properties subject to special flood hazards as identified by the FEMA in the FIS for Orange County, California and Incorporated Area with accompanying FEMA FIRMs. The amendments to Title 21 largely mirror the amendments proposed for Title 20. 8. The LCPA was submitted to the California Coastal Commission (“CCC”) and deemed complete on April 15, 2024. Because the CCC has not yet approved the LCPA, and Ordinance No. 2023-10 to amend Title 20 is not yet in effect, a variance is necessary to authorize the proposed encroachments in the side setbacks. 9. A public hearing was held on October 3, 2024, in the Council Chambers located at 100 Civic Center Drive, Newport Beach, California. A notice of time, place and purpose of the hearing was given in accordance with California Government Code Section 54950 et seq. (“Ralph M. Brown Act”) and Chapters 20.62 and 21.62 (Public Hearings) of the NBMC. Evidence, both written and oral, was presented to, and considered by, the Planning Commission at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. The Project is exempt from the California Environmental Quality Act (“CEQA”) pursuant to Sections 15303 under Class 3 (New Construction or Conversion of Small Structures) of the California Code of Regulations, Title 14, Division 6, Chapter 3 (CEQA Guidelines) because it has no potential to have a significant effect on the environment. 2. Class 3 exempts the construction of limited numbers of new, small structures, including up to three single-unit dwellings or up to six dwelling units within multi-unit structures in urbanized areas. The Project includes the demolition of one existing two-unit dwelling and construction of a new two-unit dwelling with within the Two-Unit Residential (R-2) Zoning District and the Two-Unit Residential (R-2) Coastal Zone District. 3. The exceptions to this categorical exemption under Section 15300.2 of the CEQA Guidelines are not applicable. The Project’s location does not impact an environmental 22 Planning Commission Resolution No. PC2024-021 Page 3 of 20 resource of hazardous or critical concern, does not result in cumulative impacts, does not have a significant effect on the environment due to unusual circumstances, does not damage scenic resources within a state scenic highway, is not a hazardous waste site, and is not identified as a historical resource. SECTION 3. REQUIRED FINDINGS. Variance In accordance with Subsection 20.52.090(F) (Variances – Findings and Decision) of the NBMC, the following findings and facts in support of such findings are set forth herein: Finding: A. There are special or unique circumstances or conditions applicable to the subject property (e.g., location, shape, size, surroundings, topography, or other physical features) that do not apply generally to other properties in the vicinity under an identical zoning classification. Facts in Support of Finding: 1. The Property is located on Seashore Drive and faces West Ocean Front between 39th Street and 40th Street. The Property is located within the VE Flood Zone (15 feet), which is a Special Flood Hazard Area designated by the FEMA FIRMs. This Special Flood Hazard Area designation took effect on March 21, 2019, and affects 166 beachfront properties between 28th Street and 48th Street. 2. New development within the VE Flood Zone (15 feet) is required to meet FEMA design criteria and the City’s Building Code, which require new structures to be elevated through the use of pilings, posts, piers or columns to raise the first floor of the structure to be at or above the Base Flood Elevation (“BFE”) of 15 feet North American Vertical Datum of 1988 (“NAVD 88”), and the City requires an additional one foot of freeboard to the bottom of the lowest horizontal structural member. These structures are designed and engineered to allow water to flow below the elevated floor system without damaging the foundation or creating substantial debris. Therefore, the Project has been designed with a raised finished floor of approximately 17.25 feet NAVD 88. 3. Compliance with the VE Flood Zone design criteria presents several challenges for new residential development to also meet the requirements of Title 20 and Title 21 of the NBMC related to encroachments in setback areas. Specifically, the NBMC limits steps, landings, platforms, and similar features to 18 inches maximum within side setbacks. The NBMC also limits fences, hedges, and walls (including guardrails or handrails) to 6 feet from existing grade within side setbacks. In this case, the Property has an existing grade in the side yard which ranges from a high point of 13.32 feet NAVD 88 to a low point of 11.33 feet NAVD 88, where the finished floor is at 17.25 feet NAVD 88 or between 3.93 feet and 5.92 feet from existing grade. Therefore, typical stairs, landings, handrails, and similar features that provide access from the street, side yard, or front 23 Planning Commission Resolution No. PC2024-021 Page 4 of 20 yard cannot be accommodated within the side setbacks. 4. Other properties in the VE Flood Zone would also be subject to these same special or unique circumstances. However, most properties in the City that are within the Zoning District would not be subject to the same FEMA requirements. 5. The Applicant seeks a variance for two entry stairs to exceed the maximum height in the side setback to provide access to each unit. The proposed top of landing height for both entry stairs in setback is approximately 4 feet, 4 inches above existing grade, which exceeds the maximum 18-inch height allowance for steps in the side yard setback. The proposed handrails and guardrails associated with the two entry stairs would reach a height of approximately 7 feet, 9 inches and would not exceed the minimum height required by the California Building Code (“CBC”), as certified in Title 15 (Buildings and Construction) of the NBMC. Due to the elevation difference between the existing grade and the required finished floor, exterior entry stairs are not feasible without relief from the maximum allowed height. 6. The Applicant seeks a variance for one entry stair to exceed the maximum height in the front setback to provide access to the beach. The proposed top of landing height for the entry stairs in front setback is approximately 5 feet, 4 inches (guardrail included) above existing grade, which exceeds the maximum 42-inch height allowance for fences, hedges, and walls in the front setback. The proposed handrails and guardrails associated with the entry stair would not exceed the minimum height required by the California Building Code (“CBC”), as certified in Title 15 (Buildings and Construction) of the NBMC. Due to the elevation difference between the existing grade and the required finished floor, exterior entry stairs are not feasible without relief from the maximum allowed height. Finding: B. Strict compliance with Zoning Code requirements would deprive the subject property of privileges enjoyed by other properties in the vicinity and under an identical zoning classification. Facts in Support of Finding: 1. Facts in support of Finding A are hereby incorporated by reference. 2. Strict compliance with Title 20 and Title 21 of the NBMC would deprive the Project of livable floor area as the Property is 25 feet in width, which is relatively narrow for typical R-2 Zoned properties in the City. Similarly zoned properties with similar or even larger widths outside of the VE Flood Zone can construct an entryway facing the side yard setback without the necessity of entry stairs. A compliant design would require redesigning the floor plan to pull the three entry stairs out of the side yard setback and into the buildable area of the home. This relocated design would reduce the amount of practical living area by about 95 square feet on a modest sized 2,009-square-foot lot. 24 Planning Commission Resolution No. PC2024-021 Page 5 of 20 3. Strict compliance with Title 20 and Title 21 of the NBMC would deprive the Property of direct access from the dwelling onto the front yard patio that fronts the public beach. Neighboring properties, as well as the existing Property, include patio areas abutting the beach which is directly accessible from the dwelling. Title 20 and Title 21 of the NBMC permit accessory stairs, including guardrails, to be a maximum height of 42 inches from existing grade in the front setback. The Project is designed with features in the front setback that comply with the 42-inch height allowance with the exception of the required safety railing. However, the entry stairs in the side setback that provide direct access to the beach from the elevated first floor would not be feasible, as the limit is 18 inches maximum from existing grade. Without entry stairs in the side setback, residents of Unit B would be required to travel down an entry stair that is incorporated into the building area to exit the dwelling unit with no direct access to the beach. Without the encroachment, access to the dwelling would be from the garage entry at the rear of the property, which is not typical of other R-2 Zoned properties. Finding: C. Granting of the variance is necessary for the preservation and enjoyment of substantial property rights of the Applicant. Facts in Support of Finding: 1. Facts in support of Finding A and B are hereby incorporated by reference. 2. The Applicant is requesting a means of direct access to the front patio through stairs which encroach into the side setback area that leads to the beach front. Direct access onto the front patio is a significant benefit of the Property that has existed since the residences were originally constructed and is necessary for the enjoyment of the beach front property. 3. The Applicant is requesting three sets of entry stairs for the two-unit dwelling within the front and side setback that allow for direct access into each dwelling unit. Without these entry stairs, the only way to access the units would be to enter from the garage level and travel up the internal stairway onto the main level with the elevated finished floor. Residences of similar lot size and topography located outside of the VE Flood Zone have side yard access into the dwelling that complies with Title 20 and Title 21 the NBMC because the finished floor is on, or near, the existing ground. Direct access into the dwelling without needing to travel through the garage level is necessary for the enjoyment of substantial property rights of the Applicant. Finding: D. Granting of the variance will not constitute a grant of special privilege inconsistent with the limitations on other properties in the vicinity and in the same zoning district. Facts in Support of Finding: 25 Planning Commission Resolution No. PC2024-021 Page 6 of 20 1. Facts in support of Finding A are hereby incorporated by reference. 2. Facts in support of Finding C are hereby incorporated by reference. 3. Residences of similar lot size and topography located outside of the VE Flood Zone or constructed prior to the new flood hazard requirements are typically able to accommodate access stairs in the side and front yard setbacks without deviations from development standards. The requested deviations for the Project will provide privileges that are consistent with other properties in the vicinity. 4. Further, the City is currently processing an LCPA with the CCC which would allow these encroachments to be permitted without a variance. The amendments to Title 20 of the NBMC were approved by the City Council on June 27, 2023 (Ordinance No. 2023-10). The Project is consistent with the allowed encroachments proposed in the amendments. Therefore, the requested deviations are expected to be typical of new development in the VE Flood Zone. Finding: E. Granting of the variance will not be detrimental to the harmonious and orderly growth of the City, nor endanger, jeopardize, or otherwise constitute a hazard to the public convenience, health, interest, safety, or general welfare of persons residing or working in the neighborhood. Fact in Support of Finding: 1. The entry stairs from the balcony into the front setback are not detrimental to surrounding properties. The front yard setback contains the lowest three steps of the staircase which do not reach the 42” height limit for fences, hedges and walls in the front yard setback. The guardrails will be designed with open metal material to minimize the visual impact to neighboring properties and individuals along the beach. 2. The granting of entry stairs is not detrimental to the neighborhood, as the entry stairs and landings are not visible from neighboring properties. The maximum height for entry stairs in a side yard setback area is 18 inches from existing grade, and the maximum height for accessory guardrails is 6 feet from existing grade. The proposed entryway stairs in the side setback are 4 feet, 4 inches high from existing grade, which exceeds the Title 20 and Title 21 standards by 2 feet, 8 inches. The proposed handrails and guardrails associated with the two entry stairs would reach a height of approximately 7 feet, 9 inches and would not exceed the minimum height required by the CBC as certified in Title 15 (Buildings and Construction) of the NBMC for safety purposes. Although the proposed guardrails and handrails may be visible to the adjacent properties at about 7 feet, 9 inches above grade, they are designed with open metal material to minimize the visual impact from the neighboring properties. The handrails and guardrails would also be oriented so that they run along the sides of the staircases and do not directly face the street, which would also minimize visual impacts. 26 Planning Commission Resolution No. PC2024-021 Page 7 of 20 Finding: F. Granting of the variance will not be in conflict with the intent and purpose of this section, this Zoning Code, the General Plan, or any applicable specific plan. Facts in Support of Finding: 1. Granting the variance request would not increase the density beyond what is planned for the area, and will not result in additional traffic, parking, or demand for other services. 2. The three entry stairs are not in conflict with the intent of the maximum 18-inch height standard in Title 20 and Title 21 of the NBMC. The three guardrail and handrail systems are not in conflict with the intent of the 6-foot maximum height standard in Title 20 and Title 21 of the NBMC. The intent of the Code is to prevent the re-grading of setback areas to be significantly higher than the existing grade and to prevent high raised decks, landings, patios, platforms, steps, or similar structures in the side setbacks that abut neighboring side yards and potentially impact privacy. The proposed entry stairs are intended for access into the two units. Additionally, the 6-foot maximum height standard for fences, hedges, and walls including guardrail and handrails, is to allow for adequate light and air into neighboring setbacks and to prevent the appearance of the building being walled off from surrounding areas. In this case, the guardrails and handrails will be comprised of open metal material which will reduce the appearance of bulk and allow the passage of light into adjacent spaces. 3. The Property is not located within a specific plan area.
 Coastal Development Permit In accordance with NBMC Subsection 21.52.015(F) (Coastal Development Permits - Findings and Decision), the following findings and facts in support of such findings as set forth: Finding: G. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: 1. With exception of the requested variance for the entry stair deviations, the Project complies with applicable residential development standards including, but not limited to, floor area limitation, setbacks, height, and parking. a. The maximum floor area limitation is 2,877 square feet and the proposed floor area is 2,762 square feet. 27 Planning Commission Resolution No. PC2024-021 Page 8 of 20 b. The Project provides the minimum required setbacks, which are 5 feet along the front property line abutting West Ocean Front and three feet along each side property line. There is no required setback along the property line abutting Seashore Drive. c. The Project includes one single-car garage for each dwelling unit and one covered carport for each dwelling unit for a total of four parking spaces, which complies with the minimum parking requirement for two-unit dwellings. d. The highest guardrail is less than 24 feet from established grade (17.25 feet NAVD 88) and the highest ridge is no more than 29 feet from established grade, which comply with the maximum height requirements. Pursuant to Section 21.30.060(B) (Height of Structures and Measurement) of the NBMC, the minimum required top of slab elevation for interior living areas of all new development within flood hazard areas shall be as established by the FIRM recognized by the Building Division as part of flood safety requirements and maps adopted by the Council. The Property is located in the VE Flood Zone and the minimum required top of slab elevation shall be at least 17.25 feet NAVD 88. Pursuant to 21.30.060(B) (Height of Structures and Measurement) of the NBMC, the height of a principal structure shall be measured from the top of slab elevation. Therefore, the established grade for the Property is 17.25 feet NAVD 88, and the maximum elevation allowed for a guardrail or flat roof is 41.25 feet NAVD 88 and 46.25 feet NAVD 88 for a sloping roof (minimum 3:12 pitch). 2. The neighborhood is predominantly developed with two and three-story, single-unit and two-unit dwellings. The proposed design, bulk, and scale of the development are consistent with the existing and anticipated neighborhood pattern of development. 3. A Coastal Hazards Report and Sea Level Rise Analysis was prepared by GeoSoils, Inc., dated November 9, 2022, for the Project. The report concludes that the Project will be reasonably safe from wave overtopping and future sea level rise. The estimates assume an approximate 3.2-foot increase from sea level rise over the next 75 years (i.e. the life of the structure). The maximum water elevation is 7.7 feet NAVD 88; therefore, the future sea level is estimated to reach approximately 10.9 feet NAVD 88 (the likely range for sea level rise over 75-year design life of the structure based on low risk aversion estimates for sea level rise provided by the State of California, Sea Level Rise Guidance: 2018 Update). Additionally, the maximum water elevation using the medium-high risk aversion estimate (0.5% probability) is 13.7 feet NAVD 88. The finished floor elevation of the first floor of the proposed structure is approximately 17.25 feet NAVD 88, which complies with the minimum 9.0-foot NAVD 88 elevation standard for new structures and exceeds the minimum requirements for future sea level rise (10.9 feet NAVD 88). 4. The Coastal Hazards Report and Sea Level Rise Analysis also evaluates the potential for shoreline erosion and wave action at the site. The report concludes that future wave runup will likely not reach the site under severely eroded beach conditions and extreme storms. The report states that this section of Newport Beach does experience short term 28 Planning Commission Resolution No. PC2024-021 Page 9 of 20 erosion, but that the erosion is temporary and largely the result of an energetic winter. The report concludes that the sandy beach in front of the property is typically over 350 feet wide and has provided adequate protection for the property over the last several decades. The Project will not need shoreline protection over the life of the development. 5. The Project will be reviewed for compliance with CBC and FEMA standards prior to issuance of a building permit. The Project has been designed with a raised finished floor of 17.25 feet NAVD 88, in compliance with FEMA standards. The residential structure is also required to have a pile foundation. Therefore, although unlikely to occur at the Property over the life of the development, the structure has been designed to withstand potential wave action or overtopping in compliance with the FEMA VE Flood Zone standards. 6. The Project does not include the construction of any shoreline protective devices such as seawalls or bulkheads. By nature, any features below the design flood elevation (16 feet NAVD 88) must be open to allow water to flow freely below the raised foundation. For example, stairs in the side setbacks are required to have open treads so water may flow through them. This is a fundamental building requirement in the VE Flood Zone. This is required for any structures (except those specifically exempted like elevators) that are located below the design flood elevation. Therefore, the proposed encroachments would not result in the creation of new shoreline protective devices. Further, pursuant to Section 21.30.030(C)(3)(i)(iv) (Protective Structures) of the NBMC, the Owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). 7. The Owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with Section 21.30.015(D)(3)(c) (Waterfront Development) of the NBMC. Both requirements are included as conditions of approval that will need to be satisfied prior to final building inspection, and prior to the issuance of building permits, respectively. 8. The Property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the CBC and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC prior to building permit issuance. 9. The Property is located on a wide beach, approximately 250 feet from the mean high tide line. A Construction Erosion Control Plan was provided to implement temporary Best Management Practices (“BMPs”) during construction to minimize erosion and sedimentation and to minimize pollution of runoff and coastal waters derived by construction chemicals and materials. The Project design also addresses water quality through the inclusion of a post-construction drainage system that includes drainage and percolation 29 Planning Commission Resolution No. PC2024-021 Page 10 of 20 features designed to retain dry weather and minor rain event runoff on-site. Any water not retained on-site is directed to the City’s storm drain system. 10. Pursuant to Section 21.35.050 (Water Quality and Hydrology Plan) of the NBMC, due to the proximity of the development to the shoreline and the development containing more than 75% impervious surface area, a Water Quality and Hydrology Plan (“WQHP”) is required. A preliminary WQHP has been prepared for the Project by DNZ Engineering. The WQHP includes a polluted runoff and hydrologic site characterization, a sizing standard for BMPs, use of an LID approach to retain the design storm runoff volume on site, and documentation of the expected effectiveness of the proposed BMPs. 11. Although the Project does not propose any landscaping, condition of approval No. 9 and No. 10 requires drought-tolerant species be planted should the Applicant choose to revise the Project to include landscaping. Prior to issuance of building permits, the final landscape plan will be reviewed to verify invasive species are not planted. 12. The Property is not located adjacent to a coastal viewpoint as identified in the Coastal Land Use Plan. The nearest coastal viewpoint is Newport Island Park and is not visible from the site. The Property is located adjacent to Seashore Drive, where intermittent views of the beach are provided at intersections with street ends. As currently developed, the existing property and other residences along Seashore Drive impede views of the ocean from Seashore Drive and provide very limited opportunities to see the beach through side yard setbacks. The Property is located in the middle of the block, and existing views of the beach are available along the 39th and 40th Street ends. The Project would not block any existing views through the project site, as there are no existing views through the site. Additionally, the proposed two-unit dwelling complies with all applicable Title 21 development standards and maintains a building footprint consistent with the expected neighborhood pattern of development. 13. The Property is located in the viewshed of the public beach, which is not a designated viewpoint but provides scenic views of the ocean. The Project will replace an existing two- unit dwelling with a new two-unit dwelling that complies with applicable development standards. The Project also complies with the City’s Residential Design Standards provided in Title 20 (Planning and Zoning) of the NBMC that restrict the size and location of third floors. Although not required, the Project proposes a third floor of only 262 square feet to accommodate a family room, bedroom, bathroom and covered balcony, which meets the additional 15-foot stepback standards from the front and rear setback lines. Compliance with third floor standards minimize the appearance of bulk and scale from the adjacent beach, neighboring properties, and street. 14. The Project would be constructed with a finished floor that is between 3.39 feet and 5.92 feet above the existing beach elevation and the overall height of the structure will appear higher than neighboring properties. However, as the other 165 properties along the beach from 24th Street to 48th street redevelop, they will also be required to comply with the VE Flood Zone construction standards that necessitate raised foundations on caissons. Therefore, the Project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. 30 Planning Commission Resolution No. PC2024-021 Page 11 of 20 Finding: H. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. Facts in Support of Finding: 1. The Property is located between the nearest public road and the sea or shoreline. Section 21.30A.040 (Determination of Public Access/Recreation Impacts) of the NBMC requires that the provision of public access bear a reasonable relationship between the requirement and the Project’s impact and be proportional to the impact. In this case, the Project replaces an existing two-unit dwelling located on standard R-2 lot with a new two-unit dwelling. Therefore, the Project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. Furthermore, the Project is located in the middle of the block, and designed and sited (appropriate height, setbacks, etc.) so as not to block or impede existing public access opportunities. 2. Vertical access to the beach is available at the 39th and 40th Street-ends. Lateral access is available on the beach. The Project design does not include any unique features in the rear of the property that could obstruct access or create hazards for the motorists or pedestrians on Seashore Drive. The carport posts are setback approximately two feet from the property line, which would allow the residents additional visibility to the bike path and street as they enter and exit the garage. 3. The Project does not involve the removal or creation of additional street parking spaces. In accordance with NBMC Section 21.52.090 (Relief from Implementation Plan Development Standards), the Planning Commission may approve a waiver to a development standard of the Implementation Plan only after making the following findings: Finding: I. The Planning Commission has considered the following: i. Whether or not the development is consistent with the certified Local Coastal Program to the maximum extent feasible; and ii. Whether or not there are feasible alternatives that would provide greater consistency with the certified Local Coastal Program and/or that are more protective of coastal resources. Facts in Support of Finding: 1. The proposed deviations for entry stairs within front and side setbacks are designed to 31 Planning Commission Resolution No. PC2024-021 Page 12 of 20 be consistent with the Coastal Land Use Plan and Title 21 to the maximum extent feasible. The deviations are also consistent with the LCPA that is currently being processed with the CCC. The proposed top of landing height for the staircases in the side setback is approximately 4 feet, 4 inches, which exceeds the maximum 18-inch height requirements for steps in the side yard setback. The existing patio grade is 14.72 feet NAVD 88, 2.53 feet lower than the required 17.25-foot NAVD 88 finished floor of the two-unit dwelling. The guardrails, which are the tallest element of the stairs are a maximum height of 5 feet, 4 inches above the existing grade. 2. The existing grade below the proposed stairs is 12.07 feet NAVD 88, which is 5.18 feet lower than the required 17.25-foot NAVD 88 finished floor for the dwelling. Exterior entryways into the two units are not feasible without relief from the maximum stair and fence height limits. The three entry stairs are designed to the minimum height necessary to provide access to the units while meeting safety standards of the CBC as certified in Title 15 (Buildings and Construction) of the NBMC. 3. An alternative to the entry stairs for the two-unit dwelling is to have the entrance at the side yard grade level and to design a stair system within the buildable area outside of the setback. Stairs within the buildable area count as floor area but reduce the opportunity for practical living areas such as living rooms and bedrooms. The Project is already significantly impacted by the minimum design requirements of the VE Flood Zone. Interior stairs would not provide greater consistency with the LCP and are not more protective of coastal resources. 4. Designing a separate entrance on each side of the two-unit dwelling that is within the buildable area is not realistic. The lot is 2,009 square feet and 25-feet wide with 3-foot side setbacks on each side, leaving a 19-foot-wide buildable frontage. If each entrance is at least three feet deep on each side, that would leave a width of 13 feet for living area. Thus, the lot is not wide enough to allow for separate entrances for both the units. Therefore, the side yard entry is the most feasible means of entry for the two-unit dwelling. Finding: J. The granting of the variance is necessary due to special circumstances applicable to the property, including location, shape, size, surroundings, topography, and/or other physical features, the strict application of the development standards otherwise applicable to the property denies the property owner privileges enjoyed by other property owners in the vicinity and in the same coastal zoning district. Fact in Support of Finding: Facts in Support of Finding A above are hereby incorporated by reference. Finding: K. The variance complies with the findings required to approval a coastal development 32 Planning Commission Resolution No. PC2024-021 Page 13 of 20 permit in NBMC Section 21.52.015(F). Fact in Support of Finding: Facts in Support of Findings G and H above are hereby incorporated by reference. Finding: L. The variance will not result in development that blocks or significantly impedes public access to and along the sea or shoreline and to coastal parks, trails, or coastal bluffs. Facts in Support of Finding: 1. Facts 12 and 13 in support of Finding G are hereby incorporated by reference. 2. Facts in support of Finding H are hereby incorporated by reference. Finding: M. The variance will not result in development that blocks or significantly impairs public views to and along the sea or shoreline or to coastal bluffs and other scenic coastal areas. Facts in Support of Finding: 1. Fact 12 and 13 in support of Finding G above is hereby incorporated by reference. 2. Although the Property allows for 6-foot-tall walls in the side setback, the interior side yards of the Property with the Project encroachments are designed with guard rails with open metal material to minimize the visual impact from the neighboring properties and to soften the visual impacts of the building mass. Finding: N. The variance will not result in development that has an adverse effect, either individually or cumulatively, on coastal resources, including wetlands, sensitive habitat, vegetation or wildlife species. Fact in Support of Finding: The Property is not located on or near coastal resources such as wetlands, sensitive habitat, vegetation, or wildlife species. There are no other coastal resources in the immediate area that could be affected by the proposed redevelopment. Finding: O. The granting of the variance will not be contrary to, or in conflict with, the purpose of this 33 Planning Commission Resolution No. PC2024-021 Page 14 of 20 Implementation Plan, nor to the applicable policies of the Local Coastal Program. Fact in Support of Finding: 1. Facts in Support of Finding G above are hereby incorporated by reference. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Planning Commission of the City of Newport Beach hereby finds this Project is categorically exempt from the California Environmental Quality Act pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3, because it has no potential to have a significant effect on the environment. 2. The Planning Commission of the City of Newport Beach hereby approves PA2023-0018 to allow a Variance and Coastal Development Permit, subject to the conditions set forth in Exhibit “A,” which is attached hereto and incorporated herein by reference. 3. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 (Local Coastal Program Implementation Plan), of the NBMC. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 (Appeal to the Coastal Commission) of the NBMC and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the California Public Resources Code. PASSED, APPROVED, AND ADOPTED THIS 3RD DAY OF OCTOBER, 2024. AYES: NOES: ABSTAIN: ABSENT: BY:_________________________ Mark Rosene, Chair BY:_________________________ David Salene, Secretary 34 Planning Commission Resolution No. PC2024-021 Page 15 of 20 Attachment(s): Exhibit A – Conditions of Approval 35 Planning Commission Resolution No. PC2024-021 Page 16 of 20 EXHIBIT “A” CONDITIONS OF APPROVAL (Project-specific conditions are in italics) Planning Division 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. The Project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 3. The Applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Use Permit. 4. The Variance and Coastal Development Permit filed as PA2023-0018 shall expire unless exercised within 24 months from the date of approval as specified in Section 20.54.060 and Section 21.54.060 of the NBMC, unless an extension is otherwise granted by the Community Development Director. 5. This Variance and Coastal Development Permit may be modified or revoked by the Planning Commission should they determine that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the Property is operated or maintained so as to constitute a public nuisance. 6. Any change in operational characteristics, expansion in area, or other modification to the approved plans, shall require an amendment to this Variance and Coastal Development Permit or the processing of a new Variance and Coastal Development Permit. 7. A copy of the Resolution, including conditions of approval Exhibit “A” shall be incorporated into the Building Division and field sets of plans prior to issuance of the building permits. 8. The guardrails and handrails located within the side setbacks (associated with the stair encroachments) shall be constructed of glass or open material so that 40% of the guardrails are open throughout. 9. Prior to the issuance of building permits, the Applicant shall submit a landscape and irrigation plan prepared by a licensed landscape architect. These plans shall incorporate drought tolerant plantings and water efficient irrigation practices, and the plans shall be approved by the Planning Division. 36 Planning Commission Resolution No. PC2024-021 Page 17 of 20 10. All landscape materials and irrigation systems shall be maintained in accordance with the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 11. Prior to final building permit inspection, an agreement in a form approved by the City Attorney between the Owner and the City shall be executed and recorded waiving rights to the construction of future shoreline protection devices to address the threat of damage or destruction from waves, erosion, storm conditions, landslides, seismic activity, bluff retreat, sea level rise, or other natural hazards that may affect the property, or development of the property, today or in the future. The agreement shall be binding against the Owners and successors and assigns. 12. Prior to the issuance of a building permit, the Owner shall submit a notarized signed letter acknowledging all hazards present at the site, assuming the risk of injury or damage from such hazards, unconditionally waiving any claims of damage against the City from such hazards, and to indemnify and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of development. This letter shall be scanned into the plan set prior to building permit issuance. 13. The Applicant is responsible for compliance with the Migratory Bird Treaty Act (MBTA). In compliance with the MBTA, grading, brush removal, building demolition, tree trimming, and similar construction activities shall occur between August 16 and January 31, outside of the peak nesting period. If such activities must occur inside the peak nesting season from February 1 to August 15, compliance with the following is required to prevent the taking of native birds pursuant to MBTA: A. The construction area shall be inspected for active nests. If birds are observed flying from a nest or sitting on a nest, it can be assumed that the nest is active. Construction activity within 300 feet of an active nest shall be delayed until the nest is no longer active. Continue to observe the nest until the chicks have left the nest and activity is no longer observed. When the nest is no longer active, construction activity can continue in the nest area. B. It is a violation of state and federal law to kill or harm a native bird. To ensure compliance, consider hiring a biologist to assist with the survey for nesting birds, and to determine when it is safe to commence construction activities. If an active nest is found, one or two short follow-up surveys will be necessary to check on the nest and determine when the nest is no longer active. 37 Planning Commission Resolution No. PC2024-021 Page 18 of 20 14. Best Management Practices (BMPs) and Good Housekeeping Practices (GHPs) shall be implemented prior to and throughout the duration of construction activity as designated in the Construction Erosion Control Plan. 15. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far away from storm drain systems or receiving waters as possible. 16. Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stockpiles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway. 17. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. 18. Construction activities shall comply with Section 10.28.040 of the Newport Beach Municipal Code, which restricts hours of noise-generating construction activities that produce noise to between the hours of 7:00 a.m. and 6:30 p.m., Monday through Friday. Noise-generating construction activities are not allowed on Saturdays, Sundays or Holidays. 19. Should the Property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the property owner or the leasing agent. 20. This approval shall expire and become void unless exercised within 24 months from the actual date of review authority approval, except where an extension of time is approved in compliance with the provisions of Title 20 Planning and Zoning of the Newport Beach Municipal Code. 21. To the fullest extent permitted by law, the Applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of Barnard Residence including, but not limited to a variance and coastal development permit. This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by Applicant, City, and/or the parties initiating or bringing such proceeding. The Applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which City incurs in enforcing the indemnification provisions set forth in this 38 Planning Commission Resolution No. PC2024-021 Page 19 of 20 condition. The Applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. Building Division 22. The Applicant is required to obtain all applicable permits from the City’s Building Division and Fire Department. The construction plans must comply with the most recent, City- adopted version of the California Building Code. The construction plans must meet all applicable State Disabilities Access requirements. Approval from the Orange County Health Department is required prior to the issuance of a building permit. 23. The Applicant shall employ the following best available control measures (“BACMs”) to reduce construction-related air quality impacts: Dust Control • Water all active construction areas at least twice daily. • Cover all haul trucks or maintain at least two feet of freeboard. • Pave or apply water four times daily to all unpaved parking or staging areas. • Sweep or wash any site access points within two hours of any visible dirt deposits on any public roadway. • Cover or water twice daily any on-site stockpiles of debris, dirt or other dusty material. • Suspend all operations on any unpaved surface if winds exceed 25 mph. Emissions • Require 90-day low-NOx tune-ups for off road equipment. • Limit allowable idling to 30 minutes for trucks and heavy equipment. Off-Site Impacts • Encourage carpooling for construction workers. • Limit lane closures to off-peak travel periods. • Park construction vehicles off traveled roadways. • Wet down or cover dirt hauled off-site. • Sweep access points daily. • Encourage receipt of materials during non-peak traffic hours. • Sandbag construction sites for erosion control. Fill Placement • The number and type of equipment for dirt pushing will be limited on any day to ensure that SCAQMD significance thresholds are not exceeded. • Maintain and utilize a continuous water application system during earth placement and compaction to achieve a 10 percent soil moisture content in the top six-inch surface layer, subject to review/discretion of the geotechnical engineer. 24. Prior to the issuance of a grading permit, the Applicant shall prepare and submit a Water Quality Management Plan (WQMP) for the proposed project, subject to the approval of the Building Division and Code and Water Quality Enforcement Division. The WQMP 39 Planning Commission Resolution No. PC2024-021 Page 20 of 20 shall provide appropriate Best Management Practices (BMPs) to ensure that no violations of water quality standards or waste discharge requirements occur. 25. A list of “good housekeeping” practices will be incorporated into the long-term post- construction operation of the site to minimize the likelihood that pollutants will be used, stored or spilled on the site that could impair water quality. These may include frequent parking area vacuum truck sweeping, removal of wastes or spills, limited use of harmful fertilizers or pesticides, and the diversion of storm water away from potential sources of pollution (e.g., trash receptacles and parking structures). The Stage 2 WQMP shall list and describe all structural and non-structural BMPs. In addition, the WQMP must also identify the entity responsible for the long-term inspection, maintenance, and funding for all structural (and if applicable Treatment Control) BMPs. 26. Walls located below the Design Flood Elevation (DFE) shall be designed as breakaway walls per the National Flood Insurance Program (NFIP) 60.3(e)(5). 27. Elevators shall be designed per the American Society of Civil Engineers (ASCE) 24 Section 7.5. 28. Stairs located below the DFE shall be constructed of flood damage resistant material and be of open design per NFIP 60.3(e)(5) and ASCE 24 Section 8.1. Public Works Department 29. The Applicant shall install a new sewer clean out on the existing sewer lateral per City Standard 406. 30. The Applicant shall relocate the water meter to the public right of way per City Standard 502. 31. Each unit shall be served by separate sewer and water service. Fire Department 32. NFPA 13D fire Sprinkler system required 33. Separate water meters shall be provided for each unit of the two-unit residence. 40 Attachment No. PC 2 Project Description and Justification Letter 41 IN T E N T I O N A L L Y B L A N K P A G E 42 503 32nd Street. Suite 130 Newport Beach California 92663 ph.949.584.8987 ritnergroup.com August 15, 2024 Oscar Orozco City of Newport Beach Planning Division 100 Civic Center Drive Newport Beach, CA Project: 3907 Seashore Drive Newport Beach, CA PC2023-2325 Owner: Ken & Stephanie Barnard VARIANCE REQUEST. Justification PROJECT SUMMARY: We are requesting a Coastal Development Permit for demolition of an existing duplex and for construction of a new, 2,318-square foot, duplex with an attached 444-square foot, two-car garage and two-car carport in the VE Special Flood Hazard Area 15’ (VE Flood Zone). Additionally, we are requesting a variance from the building code for the following deviations: 1. To construct exterior entryway stairs for Unit A that is 60 inches in height to landing with a 42- inch-high iron picket guardrail in the South side yard setback, where the maximum allowable height is 18 inches measured from top of grade. 2. To construct exterior stairway stairs for Unit B that is 60 inches in height to landing, with a 42-inch iron picket guardrail in the North side yard setback, where the maximum allowable height is 18 inches measured from existing grade. 3. To construct exterior access stairs to oceanfront (emergency exit) that is 60 inches in height to deck, with a 42-inch glass guardrail in the West (front) setback. We believe these variances to be necessary for several reasons and that they would meet the required conditions for variance approval as provided by Section 20.52.090F. Single Unit A Residence Entryway Stairs in Side-yard Setback VE Zone 15’ flood hazard requirements dictate that the first level finish floor be elevated above existing grade. It is therefore necessary to introduce stairs into the side yards when direct access to a unit occurs. The proposed top of landing for the single unit entrance is approximately 60 inches above existing grade which exceeds the maximum allowable 18-inch height requirement for steps in a side yard setback. The existing grade below the proposed stairs is 12 feet NAVD 88, which is 5.25 feet lower than the required EL 17.25 finished floor for the single unit residence. The proposed introduction of a stair into the side yard is necessary and will require relief from the current maximum height code requirements. Strict compliance with the existing Zoning Code would require applicants to locate entry stairs (a newly introduced requirement) within the confines of the building envelope, which would ultimately reduce the project’s livable area. Prior to introduction of the VE Zone requirements, applicants for new construction were typically able to access the garage as well as conditioned areas directly from grade, adhering to the allowable code requirements without the introduction of a stair. This design practice is still common for 43 Barnard Duplex Page 2 August 15, 2024 3907 Seashore Drive Variance Request Justification.doc parcels located outside of the VE Zone. Allocation of floor area for these newly required stairs and landings has unduly burdened new compact lot design solutions within the Zone which now yield smaller square footage than their counterparts. Taking into consideration the inherent challenges associated with designing 19’ wide houses with garages, it becomes unreasonable to further reduce an applicant’s potential habitable area by 60 or 70 feet (times two) to accommodate these newly introduced regulations. To find an equitable solution for the elevated entry requirement, while yielding a comparable buildable area to neighboring properties, this Variance Application contemplates a design that integrates the vertical transition (stairs and landings) into the side yards rather than within the building envelope. To minimize visual impact associated with the stairs for each of the neighboring properties, we are proposing an open riser concrete tread with iron pickets (refer to architectural plans and details) per VE Zone compliance certification requirements. The granting of side yard entryway into Unit A is not detrimental to the surrounding neighborhood, as the entryway stairs will not be visible from neighboring properties since it would be lower in height than the allowable new side yard fences ((refer to architectural drawings). Single Unit B Residence Entryway Stairs in Side-yard Setback VE Zone 15’ flood hazard requirements dictate that the first level finish floor be elevated above existing grade. It is therefore necessary to introduce stairs into the side yards when direct access to a unit occurs. The proposed top of landing for the single unit entrance is approximately 60 inches above existing grade which exceeds the maximum allowable 18-inch height requirement for steps in a side yard setback. The existing grade below the proposed stairs is 12 feet NAVD 88, which is 5.25 feet lower than the required EL 17.25 finished floor for the single unit residence. The proposed introduction of a stair into the side yard is necessary and will require relief from the current maximum height code requirements. Strict compliance with the existing Zoning Code would require applicants to locate entry stairs (a newly introduced requirement) within the confines of the building envelope, which would ultimately reduce the project’s livable area. Prior to introduction of the VE Zone requirements, applicants for new construction were typically able to access the garage as well as conditioned areas directly from grade, adhering to the allowable code requirements without the introduction of a stair. This design practice is still common for parcels located outside of the VE Zone. Allocation of floor area for these newly required stairs and landings has unduly burdened new compact lot design solutions within the Zone which now yield smaller square footage than their counterparts. Taking into consideration the inherent challenges associated with designing 19’ wide houses with garages, it becomes unreasonable to further reduce an applicant’s potential habitable area by 60 or 70 feet (times two) to accommodate these newly introduced regulations. To find an equitable solution for the elevated entry requirement, while yielding a comparable buildable area to neighboring properties, this Variance Application contemplates a design that integrates the vertical transition (stairs and landings) into the side yards rather than within the building envelope. To minimize visual impact associated with the stairs for each of the neighboring properties, we are proposing an open riser concrete tread with iron pickets (refer to architectural plans and details) per VE Zone compliance certification requirements. The granting of side yard entryway into Unit B is not detrimental to the surrounding neighborhood, as the entryway stairs will not be visible from neighboring properties since it would be lower in height than the allowable new side yard fences ((refer to architectural drawings). 44 Barnard Duplex Page 3 August 15, 2024 3907 Seashore Drive Variance Request Justification.doc Access Stairs to Oceanfront (Emergency Exit) in Front Setback Due to VE Zone 15’ flood hazard requirements for higher finished floor, an additional set of stairs are necessary to provide access from the residence to the oceanfront, as well as providing a second exit down to grade level (on the west side) in the event of an emergency or natural disaster. The proposed top of landing for Unit A access stair is approximately 60-inches high, which exceeds the maximum 18-inch height requirement for steps in a side yard setback. The existing grade below the proposed stair is approximately 12 feet NAVD 88, which is 5.25 feet lower than the required EL 17.25 finished floor for Unit A. Due to the elevation difference between the existing grade and the required finished floor, exterior access / emergency stairs from the Unit A residence is not feasible without relief from the existing maximum height requirement. Elevated structures also may present emergency access challenges. This application contemplates integrating stairs descending from Unit A deck (ocean side) to the sand below as a second exit to ground level. Adherence to code requirements for stairway construction will necessitate introducing handrails and guardrails to the stair design, which violates the maximum allowable height requirements within the front setback. Resulting railing encroachments are designed in accordance with the VE Zone compliance certification requirements. The granting of access stairs to oceanfront is not detrimental to the surrounding neighborhood, as the access stairs will provide a second access to ground level with minimum visual impact to surrounding properties. Summary Occasionally, introduction of new regulations may create unintended consequences. As the recent addition of VE Zone 15’ regulations are layered on top of the existing Zoning Code, evidence of potential impact to subject properties come to light. We have annotated a few potential inequities that may influence the viability of future sensible design for compact housing in the area. Adherence to all building codes is indeed essential for the safety and wellbeing of residents, however competing codes may be in tension with one another at times. It becomes important to evaluate the intent of a singular code and its impact on another. VE Zone 15’ regulations are an important step towards ensuring future safety for design and construction in areas where designated. It should not however, unnecessarily devalue subject properties by significantly reducing potential buildable area available to applicants when a viable alternative is available. One purpose for the Variance process is to provide an opportunity for the Planning Commission to interpret potential overlap and tension between multiple codes and stakeholders. We are asking that you evaluate the merits of these proposed solutions. They may help to bridge the gaps that currently exist and potentially lead to a future update to the Zoning Code. Regards, Ron Ritner, AIA Principal RITNER GROUP, INC 45 IN T E N T I O N A L L Y B L A N K P A G E 46 Attachment No. PC 3 Project Plans 47 IN T E N T I O N A L L Y B L A N K P A G E 48 DETAIL REFERENCE SHEET NUMBER SECTION INDICATOR REVISION NUMBER REVISION REFERENCE PLAN NOTE REFERENCE NUMBER FLOOR PLAN, SOFFIT/UTILITY,&ELEVATION KEYNOTE SECTION INDICATOR SHEET NUMBER BUILDING SECTION PROPOSED USE: NEW DUPLEXNUMBER OF STORIES: 3 CONSTRUCTION TYPE: V-B OCCUPANCY: R-3 DWELLINGS, U- GARAGES FIRE SPRINKLERS: REQUIRED, CRC SEC. R313.3 SYSTEM - NFPA 13D SYSTEM THROUGHOUT INCLUDING ATTIC PER R309.6, R313.1, R313.2 & R313.3 ABBREVIATIONS XX XX X X WITHOUTW/O WROUGHT IRONWI WATER HEATERWH WINDOWWDW WOODWD WATER CLOSETWC WITHW/ WASHERW VERTICALVERT UNLESS OTHERWISE NOTEDUON UNFINISHEDUNFIN UNIFORM BUILDING CODEUBC TYPICALTYP TELEVISIONTV TOP OF WALLTOW TOP OF PAVINGTOP TOP OF MASONRYTOM TOP OF CURBTOC TONGUE AND GROOVET & G TELEPHONETEL TRASH COMPACTORTC T & B TOP AND BOTTOM SQUARESQ STANDARDSTD STAGGEREDSTAG SERVICE SINKSS SHELF AND POLES & P SLIDINGSL SIMILARSIM SHOWERSHOW SHEATHINGSHTG SINGLE HUNGSH SELECT STRUCTURALSS SC SOLID CORE ROUGH OPENINGRO ROOF JOISTRJ REQUIREDREQ'D REINFORCINGREINF REFRIGERATORREFR REDWOODRDWD ROOF DRAINRD RETURN AIR GRILLERAG RADIUSR POLY VINYL CHLORIDEPVC PRESSURE TREATEDPTDF POUNDS/SQUARE INCHPSI POUNDS/SQUARE FOOTPSF PAIRPR PLYWOODPLYWD PUSH-BUTTONPB OPTIONALOPT OPPOSITEOPP ON CENTEROC NOT TO SCALENTS NUMBERNO NOT IN CONTRACTNIC NG NATURAL GRADE MASONRY OPENINGMO MINIMUMMIN MANUFACTURERMFR MEDICINE CABINETMC MACHINE BOLTMB MAXIMUMMAX MASONRYMAS LAG BOLTLB INTERIORINT INSUL INSULATION HORIZONTALHORIZHEADERHDRHCHOLLOW CORE GLUE LAMINATED BEAMGLB GARBAGE DISPOSALGD GALVANIZEDGALV GAUGEGA FOOTINGFTG FOOT/FEETFT FACE OF STUDFOS FACE OF MASONRYFOM FLUORESCENTFLUOR FLOORFLR FLOOR JOISTFJ FINISHFIN FUEL GAS / FINISH GRADEFG FINISH FLOORFF FOUNDATIONFDN FORCED AIR UNITFAU EXTERIOREXT EACH WAYEW EQUIPMENTEQUIP EQUALEQ ELEVATORELEV EA EACH DOWNSPOUTDS DRAWINGDWG DOWNDN DOUBLE HUNGDH DIMENSIONDIM DIAGONALDIAG DIAMETERDIA DETAILDET DRINKING FOUNTAINDF DOUBLEDBL D DRYER CONT CONTINUOUS CONST CONSTRUCTION CONC CONCRETE COL COLUMN CLR CLEAR CLG CEILING CJ CEILING JOIST CI CAST IRON BTM BOTTOM BM BEAM BLKG BLOCKING BLDG BUILDING APPROXIMATELYAPPROX ALUMINUMAL ALTERNATEALT AIR CONDITIONINGA/C ANCHOR BOLTAB DOUGLAS FIR AD AREA DRAIN CURTAINCURT DR DOOR EL ELEVATION FD FLOOR DRAIN DISPOSALDISP GI GALVANIZED IRON GL GLASS / GLAZING LTWT LIGHTWEIGHT OSA OUTSIDE AIR TB TOWEL BAR TPD TOILET PAPER DISPENSER TEMPERED GLASSTEMP GL VTR VENT THROUGH ROOF V VOLTSGYPSUM WALLBOARDGYP BD A4.1 BUILDING SECTIONS (1/4" = 1'-0") ARCHITECTURAL A3.1 CODE COMPLIANCE: SPECIAL INSTRUCTIONS: FIRE SPRINKLER SYSTEM - NFPA 13D OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION DUPLEX SHALL HAVE INDEPENDENT FIRE RISERS FROM EACH SEPARATE WATER METER. A4.2A4.3 RITNER GROUP, INC. 503 32ND STREET, SUITE 130 NEWPORT BEACH, CA 92663 (949) 584-8987PHONE: ARCHITECT RON RITNERCONTACT: OWNER: LAGUNA HILLS, CA 92653 Email: WILLIAM GUIDERO DESIGN 425 30th STREET #23 NEWPORT BEACH, CA 92663 (949) 675-2626PHONE: BILL GUIDEROCONTACT: STRUCTURALRIGHT ENGINEERING26040 ACERO SUITE 100MISSION VIEJO, CA 92691(949) 855-2300PHONE:CONTACT: RAID GHOULI INDEX OF DRAWINGS COVER SHEET A5.1 EXTERIOR ELEVATIONS (1/4" = 1'-0") PROJECT DIRECTORY BARNARD FAMILY TRUST 26081 MERIT CIRCLE #113 CONTACT: STEPHANIE BARNARD A2.2 THIRD LEVEL FLOOR PLAN (1/4" = 1'-0")A2.3 PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: C1.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-COVER O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - C O V E R A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions N ROOF PLAN (1/4" = 1'-0") BUILDING SECTIONS (1/4" = 1'-0")BUILDING SECTIONS (1/4" = 1'-0") PROJECT DESCRIPTION: SOILS EGA CONSULTANTS 375-C MONTE VISTA AVENUE COSTA MESA, CA 92627 (949) 642-9309PHONE: DAVID WORTHINGTONCONTACT: CIVIL FORKERT ENGINEERING INC. 22311 BROOKHURST ST. # 203 HUNTINGTON BEACH, CA 62646 (714) 963-6793PHONE: CONTACT: THOMAS RUIZ T-24ENERGY CODE WORK1 PARK PLAZA, SUITE 600IRVINE, CA 92614(949) 240-1867PHONE:CARLY NOBLECONTACT: LANDSCAPEERIC FENMORE2732 EAST COAST HIGHWAY SUITE ACORONA DEL MAR, CA 92625(949) 673-5450PHONE:CONTACT: ERIC FENMORE C1.1 COVER SHEET LEGEND INSPECTION PROGRAM: 1. DEPUTY INSPECTORS ARE REQUIRED TO BE REGISTERED WITH THE CITY OF NEWPORT BEACH. VICINITY MAP 2. SPECIAL AND / OR DEPUTY INSPECTIONS SHALL BE PROVIDED DURING CONSTRUCTION ON THE FOLLOWING TYPES OF WORK: A5.2 EXTERIOR ELEVATIONS (1/4" = 1'-0") SP-1 ARCHITECTURAL SITE PLAN (1/4" = 1'-0") SECOND LEVEL FLOOR PLAN (1/4" = 1'-0") ZONING: R-2 A2.1 MAIN LEVEL FLOOR PLAN (1/4" = 1'-0") PROJECTSITE PROJECT ADDRESS 3907 SEASHORE DRIVE NEWPORT BEACH, CA. 92663 ASSESOR'S PARCEL NUMBER: 423-326-05 LOT 4, BLOCK 39 - BOOK 3, PAGE 31 CIVIL C-4 C-2 SECTIONSC-3 EROSION CONTROL PLAN PRECISE GRADING PLAN C-1 TITLE SHEET SCH1.1 WINDOW SCHEDULE & TYPES SCH2.1 DOOR SCHEDULE & TYPES A6.1 GARAGE & MAIN LEVEL ELECTRICAL PLAN (1/4" = 1'-0") A6.2 SECOND & THIRD LEVEL ELECTRICAL PLAN (1/4" = 1'-0") A1.1 SLAB EDGE PLAN (1/4" = 1'-0") A8.1 REFLECTED CEILING PLANS (1/4" = 1'-0") D1.1 ARCHITECTURAL DETAILS D2.1D3.1D4.1 ARCHITECTURAL DETAILS D4.2 ARCHITECTURAL DETAILS C-5 GEOTECH RECOMMENDATIONS A9.1 GARAGE LEVEL & MAIN LEVEL OVERLAY PLANS (1/4" = 1'-0") SOILS REPORT: PREPARED BY: EGA CONSULTANTS REPORT No WG411.1 DATED 12-13-22 PROJECT SCOPE: DEMOLITION OF EXISTING TWO-STORY DUPLEX, GARAGE AND ASSOCIATED LANDSCAPING. CONSTRUCT NEW THREE-STORY 2,318 s.f. DUPLEX WITH AN ATTACHED 444 s.f. TWO CAR GARAGE AND TWO CAR CARPORT. THE PROJECT INCLUDES HARDSCAPE AND SUBSURFACE DRAINAGE FACILITIES WITHIN THE CONFINES OF THE PRIVATE PROPERTY AND NO LANDSCAPING. DESIGN SURVEY 1 OF 1 TOPOGRAPHIC MAP Allowable Floor Area: Allowable combined Exception : Sec 20.48.180.A.1.b.i Planning Criteria SETBACKS: 0'Front 5'2nd Front 3'Side Yard 1 MAXIMUM HEIGHT: 24'Flat Roof (less than 3:12 pitch) 29'Pitched Roof (greater than 3:12 pitch) FAR: 2,009.77 Sq. Ft.Site Area MAXIMUM FLOOR AREA LIMIT: Buildable Area 2,876.66 Sq. Ft.Buildable Area 1,438.33 x 2 = 3'Side Yard 2 1,438.33 Sq. Ft. Development Standards R-2 Zone PARKING REQUIREMENTS: 2 Car off Street Parking Minimum Minimum Interior dimensions for Parkingspaces in residential zoning for a lot width30'-0" feet or less is 17'-6"x19'-0"(20.40) City of Newport Beach Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 596 Sq.Ft. 262 Sq.Ft.Third Level Living 1,448 Sq.Ft.Total Living Total Building Area 290 Sq.Ft. 870 Sq.Ft. Unit A Unit B 444 Sq.Ft. 880 Sq.Ft. 1,176 Sq.Ft. 262 Sq.Ft. 2,318 Sq.Ft. 2,762 Sq.Ft. Total 69 Sq.Ft.Second Level Deck 69 Sq.Ft. Carport 275 Sq.Ft. THIRD FLOOR LIMITATIONS: Only subsection (A)(2)(c) applyFloor & Deck Area: 15' from Front & Rear Setback LinesLocation of Structure: 388 Sq.Ft.Roof Level Deck 494 Sq.Ft. 882 Sq.Ft. 556 Sq.Ft.Total Roof Deck 529 Sq.Ft. 1,085 Sq.Ft. 99 Sq.Ft.Main Level Deck 35 Sq.Ft. 134 Sq.Ft. 580 Sq.Ft. A9.2 SECOND LEVEL & THIRD LEVEL OVERLAY PLANS (1/4" = 1'-0") Barnard Duplex 3907 Seashore Drive Newport Beach, CA T24.1a TITLE 24 ENERGY COMPLIANCE REPORT T24.1b TITLE 24 ENERGY COMPLIANCE REPORT ARCHITECTURAL DETAILSARCHITECTURAL DETAILS STRUCTURAL S-1.3 S-1.1 1ST FLOOR FRAMING PLANS-1.2 2ND FLOOR FRAMING PLAN FOUNDATION PLAN SN-1 STRUCTURAL GENERAL NOTES S-1.4 3RD FLOOR FRAMING PLANS-1.5 ROOF FRAMING PLAN SN-2 STRUCTURAL GENERAL NOTES SN-3 STRUCTURAL GENERAL DETAILS SD-1 FOUNDATION DETAILSSD-1.1 FOUNDATION DETAILSSD-2 FRAMING DETAILS SD-3 FRAMING DETAILS SD-4 FRAMING DETAILSSD-5 FRAMING DETAILSSD-6 GRADE BEAM INFORMATION T24.1c TITLE 24 ENERGY COMPLIANCE REPORTT24.1d TITLE 24 ENERGY COMPLIANCE REPORT T24.1e TITLE 24 ENERGY COMPLIANCE REPORT PROJECT DATA 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS CODE 2022 CALIFORNIA BUILDING CODE FOR STRUCTURAL PROVISIONS ONLY CHAPTER 15 OF THE NEWPORT BEACH MUNICIPAL CODE (NBMC) GENERAL NOTES: 1. THE UTILITY CONSULTING ENGINEER IS TO ATTEND ON-SITE MEETINGS WITH THE UTILITY COMPANIES TO DETERMINE ALLOWABLE LOCATIONS. A MINIMUM OF 48 HOURS WRITTEN NOTICE FOR THE MEETING IS REQUIRED. 2. REQUIRED HERS TESTING AND/OR VERIFICATION MUST BE DONE BY A CERTIFIED HOME ENERGY RATER UNDER THE SUPERVISION OF A CEC-APPROVED HERS PROVIDER USING CEC APPROVED TESTING AND/OR VERIFICATION METHODS AND MUST BE REPORTED ON THE CF-4R INSTALLATION CERTIFICATE. 3. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTAC YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. 4. PRIOR TO PERFORMING ANY WORK IN THE CITYRIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT. 5. A Cal-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5'-0" AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO PROVIDE A COPY OF OSHA PERMIT. 6. THE SETBACKS TO BE MEASURED FROM FACE OF FINISH 7. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS. 8. FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS AND HANDRAILS OR ANY COMBINATION THEREOF SHALL NOT EXCEED 42" FROM EXISTING GRADE PRIOR TO CONSTRUCTION WITHIN THE REQUIRED FRONT YARD SETBACK AREA. 9. ALL PERMITS RELATED TO THE PROPOSED PROJECT SHALL BE ISSUED AT THE SAME TIME, OR SEPARATE PLANS AND PLAN REVIEW WILL BE REQUIRED FOR ITEMS NOT ISSUED WITH THIS REVIEW. PROVIDE ADDITIONAL PERMIT WORKSHEETS FORTHE FOLLOWING: a. ACCESSORY STRUCTURES, DETACHED PATIO COVERS AND TRELLISES OR GAZEBOS. b. MASONRY OR CONCRETE FENCES OVER 3.5 FT ABOVE GRADE, OR, WITHIN OF 3' FEET OF THE PROPERTY LINE. c. RETAINING WALLS OVER 4' FROM BOTTOM OF FOUNDATION TO TOP OF WALL AND ANY RETAINING WALL WITHIN 3 FT OFPROPERTY LINE REGARDLESS HEIGHT. d. ELECTRICAL AND PLUMBING FOR EXTERIOR IMPROVEMENTS DETACHED FROM THE HOUSE (i.e. BARBEQUE, FOUNTAIN, FIRE FEATURE). BUILDING SITE IS LOCATED IN A SPECIAL FLOOD HAZARD AREA (SFHA) VE15, ESTABLISHED IN FIRM DATED MARCH 21, 2019. BASE FLOOD ELEVATION (BFE) IS 15 FEET NAVD88. BOTTOM OF THELOWEST HORIZONTAL MEMBER TO BE CLEAR ONE FOOT ABOVE THE BFE, USING NORTH AMERICA VERTICAL DATUM 1988 (NAVD88). STRUCTURES CONSTRUCTED IN WHOLE, OR IN PART, IN FLOOD HAZARD AREAS (V ZONES) AS ESTABLISHED IN FIRM DATED MARCH 21, 2019 SHALL CONFORM TO THE REQUIREMENTS OF NBMC 15.50 AND IN ACCORDANCE WITH ASCE 24 SUBJECT TO LIMITATION OF THIS CODE SECTION 15.50.100. ENCLOSED AREAS BELOW FLOOD ELEVATION SHALL COMPLY WITH ASCE 24-14 CHAPTER 4.6. THE BOTTOM OF THE LOWEST HORIZONTAL STRUCTURAL MEMBER OF THE LOWEST FLOOR SHALL BE ELEVATED IN CONFORMANCE WITH THE MINIMUM REQUIREMENTS OF TABLE 4-1 OF ASCE 24-13. DEEP FOUNDATION DESIGN SHALL COMPLY WITH SECTION 4.5.5 OF ASCE 24-14. NOTE: a. A LICENSED SURVEYOR SHALL COMPLETE A FEMA ELEVATION (EC) AND SUBMIT THE EC FOR REVIEW AND APPROVAL FROM THE CITY'S COMMUNITY RATING SYSTEM (CRS) COORDINATOR PRIOR TO REQUESTING FINAL INSPECTION.b. AN APPROVE EC MUST BE SUBMITTED TO THE BUILDING DEPARTMENT INSPECTOR DURING FINAL INSPECTION. c. ALL MECHANICAL, GAS, AND ELECTRICAL EQUIPMENT SERVICING THE BUILDING (INCLUDING DUCTS) MUST BE AT LEAST ONE FOOT ABOVE THE BFE (NAVD88). 15. 16. DEFERRED SUBMITTALS: - FIRE SPRINKLER - NFPA 13D SYSTEM THROUGHOUT INCLUDING ATTIC - MECHANICAL EQUIPMENT AND DUCTWORK - ENCROACHMENT PERMIT - SOLAR PV SYSTEM WITH MIN. 3.0 kWdc FOR DWELLING UNIT "A" AND UNIT "B" MUST BE OBTAIN UNDER A SEPARATE REVIEW & PERMIT A 5 kWh BATTERY SYSTEM IS REQUIRED FOR EACH UNIT. - SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275 - EXTERIOR STAIRS SHOP DRAWINGS GN-1 CALIFORNIA GREEN RESIDENTIAL MINIMUM REQUIREMENTS/ GN-2 RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS HOUSING CRISIS ACT COMPLIANCE FOR DEMOLITONS/30 DAY NOTICE OF INTENT TO EXCAVATE/ RECYCLE AND OR SALVAGE FOR REUSE A MINIMUM OF 65% OF THE NON-HAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH SECTION 4.408.1 CalGreen CODE. DEFERRED SUBMITTAL TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN CHECK OR APPROVAL BY THE CITY. THE MAXIMUM TIME TO COMPLETE CONSTRUCTION ON A PROJECT IS LIMITED TO THREE YEARS FROM THE DATE OF THE PERMIT FOR ALL PERMITS ISSUED AFTER AUGUST 21, 2019. NBMC SECTION 15.02.095 PROVIDE A PROJECT INFORMATION SIGN FOR PROJECTS REQUIRING FENCING (NEW STRUCTURE OR ADDITION AND REMODEL TO AN EXISTING STRUCTURE WITH A COMBINED FLOOR AREA EXCEEDING SEVENTY-FIVE (75) PERCENT OF THE FLOOR AREA OF THE PROPOSED STRUCTURE) IN DESIGNATED "HIGH DENSITY AREAS". PROJECT SIGN SHALL COMPLY WITH NBMC SECTION 15.60.030. EVIDENCE OF THE 30 DAY NOTIFICATION FOR COMPLETE DEMOLITION OR EXCAVATION TO THE ADJOINING PROPERTIES AS REQUIRED BY NBMC SECTION 15.02.120 SHALL BE SUBMITTED TO THE RESPONSIBLE ENTITY UNDER THE CITY OF NEWPORT BEACH. 10. 11. 12. 13. 14. 17. 18. 19. 20. SD-7 FRAMING SHEET WSW1 STRONG-WALL WSW WSW1.1 STRONG-WALL WSW WSW2 STRONG-WALL WSWWSW3 STRONG-WALL WSWWSW4 STRONG-WALL WSW D5.1 ARCHITECTURAL RATED WALL DETAILS GARAGE DEMO PLANC-3.1 49 CAL GREEN RESIDENTIAL MINIMUM REQUIREMENTS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: GN-1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-GBC1 O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - G B C 1 A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client RevisionsCAL GREEN - Residential Minimum Requirementsfor Demolitions Housing Crisis Act Compliance 50 RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS Residential Construction Minimum Requirements Notes PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: GN-2 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-GN2 O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - G N 2 A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Grading General Notes 51 LOT 5 LOT 3 Alley Se a s h o r e D r i v e 35'-034" 918" Up 9R 20'-412"3'-9" 4'-7" 11 58" 5'-812" 13.10 11.17 FL11.67 11.13 FL 312" 1'-0" 4'- 5 " FS 75'-8" 26'-012" 16'-11" 55'-412"5'-812" 29'-4" 13'-7" 13'-7" 75'-8" 10'-10" 3'-712" 1'-0" 34'-1112" 1'-0" 35'-0" 19'-5" 2'-4" 1'- 5 12" 2'-6" 19 ' - 1 1 18" 17' - 6 " E.G. El. 13.50 19'-1012" 13.02FS FS (14.72) 11.27 TC11.63 11.36 TC11.76 FS 0.9% 2.3%Up 8R Up7R 7.9% 1.1% 8% 3.4% 3.4% 1.7% 11.76 FS(11.6) NG 0.6% FS 17.25 BreakawayLanding Exisisting Hardscapeto Remain FS FSUp7R B A4.1 G A4.3 E A4.2 A A4.1 13.30 FS Dn 4R 1 2 7 14.70 FS 3 5 Up6R Crawl Space Garage D A4.2 FA4.3 C A4.1 4 3'-7 " 16 ' - 1 0 " 678" 3'- 3 12" 5'- 5 " 3'-0 " 6'- 4 14" 914" 2'-314"4'-434" 3'-138"2'-1"14'-258" 6'- 6 12" 812" 5'- 1 12" 4'-1012"3'-1038" 2'-4 78" 17'-6" x 19'-0" min.Parking Required 41 D001 Open Treads at 10.25" Each 49 38 22 47 48 312" 312"3'- 3 12" 3'- 0 " 812" 46 38 Unit A Unit B 6" 3'-0"2'-0" 5'-0" Setback 3'- 0 " Se t b a c k 4'-7"24'-9"5'-6" 3'-0 " Se t b a c k 1'-0 " 2'- 1 " 3'-0 " 1"5'-0"1'-0" 7'-4"6'-0" 2'-1" 6'-0"7'-012" FS (14.70) 13.67FS 13.55FS-GB 2% 2% 2% 2% 2% 6" 6" 434" 6" 12.07 FS-GB 12.63 FS 12.30 FS 2% 2% FS - GB 11.76 3'- 0 " Se t b a c k 11 . 7 6 F S 3'- 0 " Se t b a c k Dashed line Indicates 1 Hour Fire Resistance-Rated wall 14'-7" N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' Wall or floor between house Living area and garage shall be 5/8" type "X" Gyp. Bd. on garage side of wall or floor/ceiling. Rated separation must extend from floor level to roof sheathing. 1 3/4" thick self-closing & self-latching,tight fitting 45 minute rated door The entire Carport and Garage ceiling shall be 5/8" type "X" Gyp. Bd. 1W1 1W1 N52 46'30"E 54.46'Property Line N39 35'30"W 1.00'Property Line N52 46'30"E 25.00' Pr o p e r t y L i n e N3 9 3 5 ' 3 0 " W 2 6 . 0 2 ' Pro p e r t y L i n e N52 46'30"E 79.33' Property Line 3'-0 " Se t b a c k Trash Binsbelow water heaters 1.9% 11. 6 7 F S 718" 2'- 5 78"5516 "578"1'-234"438" 21316 " 5516" 1'-234"578" 6 10 58" 1'-0"678" 718" 518" W10x77 W10X77 HSS5x5x1/4 Line of Fireplace projection above 1W11W5 Water Meter Duplex shall be serviced by separate Utilities(water & Gas) Duplex shall be serviced by separate Utilities(water & Gas) Gasmeters 412" 718" 6"6" 6"6" 10 18"9" HSS5x5x1/4 W10x77 11 14" 614" 278"918" W10x30 6"6" W10x30 538" 614" 278"918"W10x77 518" 278" 1'-0" 514" 212" D002 D104 DoorAbove OpenTreadsstairs OpenTreadsstairs Open Treads stairs Open Treads stairs 11.84 TC 13.63 TC 13.30 FS 2% 13.38 TC13.30 FS TC 11.84 0.8% 19'-0" Minimum interior clear 17 ' - 6 " M i n i m u m i n t e r i o r c l e a r 3.7% 12.07 FS-GB 12.04 FS 12.04 FS 11.90 FS-GB Architectural Site Plan SCALE: 1/4" = 1'-0" ARCHITECTURAL SITE PLAN PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: SP-1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-SITE O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - S I T E A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions PROJECT ADDRESS 3907 SEASHORE DRIVENEWPORT BEACH, CA. 92663ASSESOR'S PARCEL NUMBER: 423-326-05LOT 4, BLOCK 39 BOOK 3, PAGE 316. The discharge of pollutants to any storm drainage system is prohibited. No solid waste, petroleum byproducts, soil particulate, construction waste materials, or wastewater generated on construction sites or by construction activities shall be placed, conveyed or discharged into the street, gutter or storm drain system. 7. In Accordance with Planning Area 6 (PA6) of the Headlands Development and Conservation Plan (HDCP), This house is a Single-Family Dwelling. 8. An approved encroachment permit is required for all work activities within the public right-of-way, public easement and on city facilities. 9. All work related to wastewater in the public right-of-way shall be performed by a C-42 licensed Sanitation Sewer Contractor or an A Licensed General Engineering Contractor. General Notes: 1. Refer to Site Drainage Plan sheet for existing grade elevations and finish grade elevations. 2. Surveyor or Engineer shall permanently monument property corners or offsets before starting grading. 3. Fences, Gates, Walls, Planter boxes, Patio covers, and other freestanding structures cannot exceed 6' measured from Natural Grade within required side yard setback. 4. Finish grade within 10 feet of the new structure/ addition shall be sloped a minimum of 2 % away from the building for drainage purpose. 5. Additions, remodels or renovations of a single family home with an existing pool require the suction outlet of the existing pool, spa, or toddler pool to be upgraded so as to be equipped with an approved anti-entrapment cover meeting the current standards of ASTM or ASME per section 115920 HSC. 10. A Public Works Department Encroachment Permit inspection is required before the Building Department Permit Final can be issued. At the time of Public Works Department inspection, if any of the existing public improvements surrounding the site is damaged, new concrete sidewalk, curb and gutter, and alley/street pavement will be required. Additionally, if existing utilities infrastructure are deemed substandard, a new 1-inch water service, water meter box, sewer lateral and/or cleanout with box and lid will be required. 100% of the cost shall be borne by the property owner (Municipal Codes 14.24.020 and 14.08.030). Said determination and the extent of the repair work shall be made at the discretion of the Public Works Inspector. Allowable Floor Area: Allowable combined Exception : Sec 20.48.180.A.1.b.i Planning Criteria SETBACKS: 0'Front 5'2nd Front 3'Side Yard 1 MAXIMUM HEIGHT: 24'Flat Roof (less than 3:12 pitch) 29'Pitched Roof (greater than 3:12 pitch) FAR: 2,009.77 Sq. Ft.Site Area MAXIMUM FLOOR AREA LIMIT: Buildable Area 2,876.66 Sq. Ft.Buildable Area 1,438.33 x 2 = 3'Side Yard 2 1,438.33 Sq. Ft. Development Standards R-2 Zone PARKING REQUIREMENTS: 2 Car off Street Parking Minimum Minimum Interior dimensions for Parkingspaces in residential zoning for a lot width30'-0" feet or less is 17'-6"x19'-0"(20.40) City of Newport Beach Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 596 Sq.Ft. 262 Sq.Ft.Third Level Living 1,448 Sq.Ft.Total Living Total Building Area 290 Sq.Ft. 870 Sq.Ft. Unit A Unit B 444 Sq.Ft. 880 Sq.Ft.1,176 Sq.Ft. 262 Sq.Ft. 2,318 Sq.Ft. 2,762 Sq.Ft. Total 69 Sq.Ft.Second Level Deck 69 Sq.Ft. Carport 275 Sq.Ft. THIRD FLOOR LIMITATIONS: Only subsection (A)(2)(c) applyFloor & Deck Area: 15' from Front & Rear Setback LinesLocation of Structure: 388 Sq.Ft.Roof Level Deck 494 Sq.Ft. 882 Sq.Ft. 556 Sq.Ft.Total Roof Deck 529 Sq.Ft. 1,085 Sq.Ft. 99 Sq.Ft.Main Level Deck 35 Sq.Ft. 134 Sq.Ft. 580 Sq.Ft. 0'-7 3/4"9'-3 1/4" 52 WINDOW NOTES First Floor Windows DESCRIPTION MANUFACTURE REMARKS ROOM NAMESYM WIDTH HEIGHT TYPE MATERIAL WINDOW W I N D O W S C H E D U L E SIZE FRAME DIV I D E D L I T E S HA R D W A R E MA T E R I A L QU A N T I T Y W101 U- V A L U E FENESTRATION LO W - E G L A S S RE T R A C T A B L E Left Right (O u t s i d e Family - Unit "A" W102 -2C -1C IN S I D E ( O P E R A B L E W I N D O W S O N L Y ) OP E R A T I N G DIR E C T I O N GLAZING 1 3'-0"2'-0"-1ACasement FINISH Hin g e s i d e ) 6'-0"5'-0"French Casement Dual Pane SH G C DETAILS H WINDOW J S SC R E E N S M Casement A Min. C l e a r 20"Min. Clear Dual Pane Dual Pane Master WC - Unit "A"Wood W201 W202 Master Wic - Unit "A" ---- - Second Floor Windows Tempered -3'-6"2'-0" Dual Pane 1. All Glazing to be true divided lites. All Glazing to be dual Pane Glazing with a minimum of one tempered pane2. Iron Frame Windows The General Contractor, Framer and Door and Window Installer are3.to verify all Door and Window Openings with the Shop Drawings andfield conditions. Dimensions provided on this Schedule are for the All rough opening dimensions are to be coordinated with the Doorpurpose of the preparation of the Door and Window Shop Drawings. and Window Shop Drawings. ( Failure to do so is the Responsibilityof the General Contractor and Sub Contractor.) Iron Frame Windows By: Steelworks Etc. Inc. Windows & Doors 1. All Glazing to be true divided lites. All Glazing to be Dual Pane Glazing with a minimum of one tempered pane2. Wood Windows The General Contractor, Framer and Door and Window Installer are3.to verify all Door and Window Openings with the Shop Drawings andfield conditions. Dimensions provided on this Schedule are for the All rough opening dimensions are to be coordinated with the Doorpurpose of the preparation of the Door and Window Shop Drawings. and Window Shop Drawings. ( Failure to do so is the Responsibilityof the General Contractor and Sub Contractor.) Wood Windows By: Kolbe Windows & Doors General notes Fenestrations must have temporary and permanent labels Ducts must be sealed and field verified by a HERS certified 1. 2. special inspector. The load resistance of glass under uniform load shall be3. determined in accordance with ASTM E 1300. Glazing notes Each pane of safety glazing installed in hazardous locations Glazing in swinging, sliding, and bifold doors 9 square feet or less 1. 2.shall be a minimum category classification of I ( CPSC 16 CFR 1201) Glazing over 9 square feet in area with bottom edge less than 18"3. above the floor and exposed top edge greater than 36" above shall be identified (acid etched, sand blasted, ceramic fired, etc)by a manufacturer's designation, the manufacturer or installer andthe safety glazing standard which it complies. Multi-pane assemblies shall be identified per CRC R308.1. [CRC R308.1] and II (CPSC 16 CFR 1201) when more than 9 square feet or sliding. [Table R308.3.1 (1), R308.3.1] the floor shall be safety glazed. [CRC R308.4.3] Glazing in doors and enclosures for hot tubs, whirlpools, saunas,4.steam rooms, bathrooms showers less than 5' above the standing surface shall have a minimum category classification of II (CPSC 16CFR 1201). [ CRC Table R308.3.1 (1) & 308.4.5] Egress Notes Every sleeping room shall have at least one operable emergency escape All bedrooms, basements or rooms used for sleeping shall have 1. 2.emergency rescue windows or doors. CRC R310.1: and rescue opening (Window or Door). Emergency escape and rescueopeninig shall open directly in a public way, or to a yard or court that opens to a public way. a. Minimum net clear opening of 5.7 square feet b. Minimum net clear opening of 5 square feet at grade level floor Note: in order to meet the minimum clear opening of 5.7 square feet, eitherthe width or height, or both, must exceed the minimum dimension (see figure Below). The net clear opening dimensions required shall be obtainedby the normal operation of the emergency escape and rescue openingfrom the inside. c. Minimum net clear opening width of 20 inchesd. Minimum net clear height of 24 inches e. Window sill height of not more than 44 inches above the floor CBC 708A CBC 708A A CasementWood -- Wood Tempered .32 .23 Kolbe Windows & Doors 1'-10"4'-0"D AwningMaster shower - Unit"A"WoodW203 -1-Dual Pane 2 3'-6"2'-0" -2 A Casement Dual Pane Bath 2 Wood W204 W205 Master Suite - Unit "A"-4'-6"1'-6" Dual Pane A CasementWood - W206 Master Bath - Unit "A"4'-0"3'-6"E Pocket SliderWood 1 Single Pane-Tempered Dine 6'-0"7'-0" W207 4'-6"2'-6"A CasementMaster Suite - Unit "A"Wood -1 Dual Pane Kolbe Windows & Doors Kolbe Windows & Doors Kolbe Windows & Doors Kolbe Windows & Doors KolbeWindows & Doors KolbeWindows & Doors KolbeWindows & Doors .32 .23 .32 .23 - - .32 .23 .23 .23 French Casement ----.32 .23 - - - - - - - - - -Tempered Tempered- ---- ---- ---- ---- - Tempered W301 Stair Hall Third Floor Windows 6'-0"4'-0"B Wood -1 Dual Pane-KolbeWindows & Doors.32 .25 ----Fixed W302 Bath 3 2'-6"1'-8"A Wood -1 Dual Pane---- Tempered KolbeWindows & Doors.32 .23Casement W303 Office 4'-0"1'-8"A Wood -1 Dual Pane-----.32 .23Casement - KolbeWindows & Doors Paint Grade Interior Clad Exterior Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Wood Paint Grade InteriorClad Exterior 1'-8" 4'-0 " W303 - - - - Kolbe Windows & Doors - - W I N D O W T Y P E S ABCE 4'-0" 6'- 0 " W301 W103 -2B Dual Pane Tempered-Kitchen - Unit "A"5'-0"1'-0"Fixed -----Wood Paint Grade InteriorClad Exterior .32 .25 Kolbe Windows & Doors W304 Office 4'-0"9'-6"F Wood (2) Casements mold togetherPaint Grade InteriorClad Exterior 1 Dual Pane .32 .23 KolbeWindows & Doors------ 1'-8" 2'-6 " W302 Tempered 9'-6" 4'-0 " W304 - - .32 .23 - 4'-6"2'-4"A CasementBedroom 2 WoodW208 -2 Dual Pane KolbeWindows & Doors.23-----Paint Grade InteriorClad Exterior 4'-0"4'-0"B FixedStair Hall - Unit "A"WoodW209 -1 Dual Pane KolbeWindows & Doors.25----TemperedPaint Grade InteriorClad Exterior -- 3'-0"2'-0"A CasementStair - Unit "B"WoodW210 -1 Dual Pane KolbeWindows & Doors.25----TemperedPaint Grade InteriorClad Exterior - 4'-0"2'-0"B FixedStair - Unit "B"WoodW211 -1 Dual Pane KolbeWindows & Doors.25----TemperedPaint Grade InteriorClad Exterior - - 4'-0"2'-6"B FixedFamily Volume - Unit "B"WoodW212 Paint Grade InteriorClad Exterior -3 Dual Pane----- -KolbeWindows & Doors.25- 3'-0"2'-0"B FixedWoodW213Paint Grade InteriorClad Exterior -2----- - 4'-0"4'-8"C French CasementWoodW214Paint Grade InteriorClad Exterior -1---- Dual Pane KolbeWindows & Doors.25- Dual Pane KolbeWindows & Doors.25- 3'-0"1'-8"A CasementMaster Bath - Unit "B"WoodW215 Paint Grade InteriorClad Exterior 4'-0"2'-4"A CasementMaster - Unit "B"WoodW216 Paint Grade InteriorClad Exterior -1----Dual Pane KolbeWindows & Doors.25Tempered -2----Dual Pane KolbeWindows & Doors.25- - W104 -1A Dual Pane TemperedPowder3'-6"2'-0"Casement ----Wood Paint Grade InteriorClad Exterior .32 .23 Kolbe Windows & DoorsW105 Dual Pane Tempered----.32 .23 Kolbe Windows & DoorsW106 -1A Dual Pane TemperedBath 4 3'-0"2'-0"Casement -----Wood Paint Grade InteriorClad Exterior .32 .23 Kolbe Windows & DoorsW107 -1A Dual Pane TemperedKitchen/Hall - Unit "B"3'-0"2'-0"Casement -----Wood Paint Grade InteriorClad Exterior .25 Kolbe Windows & DoorsW108 -1A Dual Pane TemperedKitchen - Unit "B"4'-0"2'-0"Casement -----Wood Paint Grade InteriorClad Exterior .25 Kolbe Windows & DoorsW109 -2A Dual Pane -Family - Unit "B"4'-0"2'-0"Casement ----Wood Paint Grade InteriorClad Exterior .25 Kolbe Windows & DoorsW110 -2A Dual Pane TemperedFamily/Stair - Unit "B"4'-0"2'-0"Casement ----Wood Paint Grade InteriorClad Exterior .25 Kolbe Windows & Doors Family Volume - Unit "B" Family Volume - Unit "B" -1 - CBedroom 3 5'-0"4'-8"French CasementWoodPaint Grade InteriorClad Exterior W111 -1B Dual Pane TemperedFamily - Unit "B"3'-6"2'-0"Fixed ----Wood Paint Grade InteriorClad Exterior .25 Kolbe Windows & DoorsW112 -1F Dual Pane -Family 3'-6"7'-0"XOX - (2) Casement, (1) Fixed Mold together ----Wood Paint Grade InteriorClad Exterior .25 Kolbe Windows & Doors - - 2'-0" 3'-6 " W201 2'-0" 3'-0 " W104 W107 4'-0" 1'-1 0 " W203 3'-6" 4'-0 " W204 2'-4" W208 4'- 6 " 2'-6" W206 4'- 6 " W207 4'-0" 4'-0 " W209 2'-0" 4'- 0 " W109 2'-6" 4'-0 " W212 2'-0" 4'-0 " W211 2'-0" 3'-0 " W213 4'-8" 4'-0 " W214 2'-0" 3'-6 " W105 2'-4" 4'- 0 " W216 7'-0" 6'-0 " W102 5'-0" 6'-0 " W101 1'-0" 5'-0 " W103 1'-8" 3'-0 " W215 4'-8" 5'-0 " W106 W108 W202 W210W111W110 2'-0" 3'- 6 " W111 7'-0" 3'- 6 " W113 D F W113 -1A Dual Pane TemperedPantry3'-0"2'-0"Casement ----Wood Paint Grade InteriorClad Exterior .32 .23 Kolbe Windows & Doors- Fenestrations must have temporary and permanent labels5. prior to final Building Inspection Approval. Fenestrations must have temporary and permanent labels5.prior to final Building Inspection Approval. .35 .35 .35 .35 .34 .35 .32 .32 .32 .32 .35 .34 .34 .34 .35 .35 .35 1'-6" W205 4'- 6 "WINDOW SCHEDULE PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: SCH-1.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-SCH11 O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - S C H 1 1 A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions 53 DOOR NOTES Garage Level Doors DESCRIPTIONROOM NAMESYM WIDTH HEIGHT QTY FINISH DOOR D O O R S C H E D U L E SIZE MATERIALTHICKNESS FINISHMATERIAL FRAME DETAILS S MATERIAL THRESHOLD REMARKS MANUFACTURE D101 D102 D103 D104 D105 D201 D202 D203 D204 D205 D206 D207 D208 D209 D106 2'-6"Master Suite U-VALUE FENESTRATION 115'-0" 1Master Bath - WC 2'-4" 7'-0"1 LITES DIVIDED Wood S.C. - Pocket Wood GLAZING 2'-4" Master Wic SecondLevel Doors SHGCJH Master Bath 1 2'-6 1 Wood Wood 12'-8" 12'-4" WoodWood Wood Wood Wood Wood 1Master Bath 2'-4" Bath 2 1 7'-0" 7'-0" 7'-0" 7'-10" Wood (4) Panel Sl. Gl. Dr. Wood Wood S.C. Wood Wood 1. All Glazing to be true divided lites. All Glazing to be dual Pane Glazing with a minimum of one tempered pane2. Iron Frame Doors The General Contractor, Framer and Door and Window Installer are3.to verify all Door and Window Openings with the Shop Drawings andfield conditions. Dimensions provided on this Schedule are for the All rough opening dimensions are to be coordinated with the Doorpurpose of the preparation of the Door and Window Shop Drawings. and Window Shop Drawings. ( Failure to do so is the Responsibilityof the General Contractor and Sub Contractor.) Iron Frame Doors By: 1. All Glazing to be true divided lites. All Glazing to be Dual Pane Glazing with a minimum of one tempered pane2. Wood Doors The General Contractor, Framer and Door and Window Installer are3.to verify all Door and Window Openings with the Shop Drawings andfield conditions. Dimensions provided on this Schedule are for the All rough opening dimensions are to be coordinated with the Doorpurpose of the preparation of the Door and Window Shop Drawings. and Window Shop Drawings. ( Failure to do so is the Responsibilityof the General Contractor and Sub Contractor.) Wood Doors By: General notes Fenestrations must have temporary and permanent labels Ducts must be sealed and field verified by a HERS certified 1. 2.special inspector. The load resistance of glass under uniform load shall be3.determined in accordance with ASTM E 1300. Glazing notes Each pane of safety glazing installed in hazardous locations Glazing in swinging, sliding, and bifold doors 9 square feet or less 1. 2. shall be a minimum category classification of I ( CPSC 16 CFR 1201) Glazing over 9 square feet in area with bottom edge less than 18"3.above the floor and exposed top edge greater than 36" above shall be identified (acid etched, sand blasted, ceramic fired, etc) by a manufacturer's designation, the manufacturer or installer andthe safety glazing standard which it complies. Multi-pane assembliesshall be identified per CRC R308.1. [CRC R308.1] and II (CPSC 16 CFR 1201) when more than 9 square feet or sliding.[Table R308.3.1 (1), R308.3.1] the floor shall be safety glazed. [CRC R308.4.3] Glazing in doors and enclosures for hot tubs, whirlpools, saunas,4.steam rooms, bathrooms showers less than 5' above the standingsurface shall have a minimum category classification of II (CPSC 16 CFR 1201). [ CRC Table R308.3.1 (1) & 308.4.5] Egress Notes Every sleeping room shall have at least one operable emergency escape All bedrooms, basements or rooms used for sleeping shall have 1. 2.emergency rescue windows or doors. CRC R310.1: and rescue opening (Window or Door). Emergency escape and rescue openinig shall open directly in a public way, or to a yard or court thatopens to a public way. a. Minimum net clear opening of 5.7 square feetb. Minimum net clear opening of 5 square feet at grade level floor Note: in order to meet the minimum clear opening of 5.7 square feet, either the width or height, or both, must exceed the minimum dimension (seefigure Below). The net clear opening dimensions required shall be obtainedby the normal operation of the emergency escape and rescue opening from the inside. c. Minimum net clear opening width of 20 inches d. Minimum net clear height of 24 inchese. Window sill height of not more than 44 inches above the floor CBC 708A CBC 708A TYPE B C Wood Stair Hall/Lau. closet Bedroom 2 Master Suite 2'-4" Pantry 18'-0"3'-0" Family - Unit "A" E 17'-0"2'-6"Stair/Hall Wood WoodA 1Powder Wood WoodA 17'-0"3'-0"Entry - Unit "B"Wood WoodE Entry - Unit "A" 7'-0"2'-4" 1 3/4" S.C. - Dutch with Glazing Stone--- .34 .23 D301 Office 11'-8" 7'-0" Third Level Doors S.C. - Pocket Sliding Glass Doors - (4) panels 7'-0" 7'-0" 7'-0" 7'-0" S.C. S.C. KolbeWindows & Doors KolbeWindows & Doors KolbeWindows & Doors KolbeWindows & Doors KolbeWindows & Doors Kolbe Windows & Doors Kolbe Windows & Doors Kolbe Windows & Doors Kolbe Windows & Doors Kolbe Windows & Doors Kolbe Windows & Doors Kolbe Windows & Doors Steelworks Etc. Inc. Windows & Doors .34 .23 S.C. - Tight Fitting 45 Min. Self closing & Self Latching 17'-10"16'-4"C 1 3/4" 1 3/4" 1 3/4" S.C. Sl. Gl. Dr. - (4) Panels Stone--- Dual Pane Tempered Dual Pane Tempered .34 .25 A B C A A A 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" A1 3/4" Stone---Dual Pane Tempered 1 Wood S.C. D302 Bath 3 2'-4" 7'-0" 1 Wood French Dr. D303 Elevator/Deck 2'-6" 7'-0" 1 Wood Barn Dr. on a steel track D304 Office 3'-8" 7'-1" A D B 1 3/4" 1 3/4" 1 3/4" 1 3/4" Wood Wood Wood KolbeWindows & Doors KolbeWindows & Doors KolbeWindows & Doors Paint Grade Paint Grade Paint Grade Paint Grade Paint Grade Paint Grade Paint Grade Paint Grade Paint Grade Paint Grade Paint Grade Paint Grade Paint Grade Fenestrations must have temporary and permanent labels5. 17'-0"2'-0"B S.C. - Pocket Wood Wood Wood Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior KolbeWindows & Doors KolbeWindows & Doors Wood Wood Wood Paint Grade InteriorClad Exterior 1 3/4" 1 3/4" 1 3/4" Paint Grade Paint Grade Paint Grade Self Closing & LatchingTight fitting 45 Minute Dr. 1 WoodA1 3/4" Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Kolbe Windows & Doors Wood S.C.WoodPaint Grade Paint Grade1 3/4" S.C. Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Stone---Dual Pane Tempered .32 .23 1 WoodABedroom 3 2'-6" 7'-0" 1 3/4"S.C.WoodPaint Grade Paint Grade 1 WoodABath 4 2'-4"7'-0"1 3/4"S.C.WoodPaint Grade Paint Grade D107 D108 D O O R T Y P E S 2'-10" 6'-8 " D213 3'-8" 7'-1 " D303 16'-10" 7'-6 " D001 D304 11'-8" 7'-0 " A BC D E F G H I Kolbe Windows & Doors 2'-6" 7'-0 " D104 Paint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior Stone---Dual Pane Tempered .34 .23 Paint Grade Paint Grade 2'-4" 7'-0 " D201D203 2'-4" 7'-0 " D105 2'-8" 7'-0 " D208 D102 16'-4" 7'-1 0 " 5'-0" 7'-0 " D212 WoodS.C.Paint Grade Paint Grade Paint Grade Paint Grade Kolbe Windows & Doors D210 ----------- D211 Master Bedroom 12'-6"Wood Wood7'-0"A1 3/4"S.C.Paint Grade Paint Grade D212 Hall 15'-0"Wood Wood7'-0"F1 3/4"S.C. - Bi-fold (4) PanelsPaint Grade Paint Grade 1 Wood S.C. with GlazingEntry2'-10" 6'-8"E1 3/4"Paint Grade InteriorClad ExteriorD213 Wood ---Paint Grade InteriorClad Exterior .34 .25StoneDual Pane Tempered Kolbe Windows & Doors Kolbe Windows & Doors KolbeWindows & Doors KolbeWindows & Doors Paint Grade Paint Grade S.C. - with GlazingPaint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior .34 .25Stone---Dual Pane Tempered 1 WoodAKitchen/Hall 2'-4" 7'-0" 1 3/4"S.C.WoodPaint Grade Paint GradeD109 1 WoodDFamily - Unit "B"2'-6" 7'-0" 1 3/4"French Dr.WoodD110 .34 .25Stone---Dual Pane Tempered KolbeWindows & Doors KolbeWindows & Doors Kolbe Windows & Doors Kolbe Windows & DoorsPaint Grade InteriorClad Exterior Paint Grade InteriorClad Exterior 2'-0" 7'-0 " D103 2'-6" 7'-0 " D110D302 3'-0" 7'-0 " D106 3'-0" 7'-0 " D101 First Level Doors D001 17'-6"16'-10"GEntry - Unit "A"Wood Wood1 3/4"Paint GradePaint Grade KolbeWindows & Doors D205 15'-0" 7'-1 0 " D107 D108D204D109D207D202D211D206D209D301 prior to final Building Inspection Approval. S.C. - Automatic roll-upSectional garage Door D002 16'-8"3'-0"Elevator Wood WoodAS.C. - Tight Fitting 45 Min.Self closing & Self Latching1 3/4"Paint GradePaint Grade Metal KolbeWindows & DoorsSelf Closing & Latching Tight fitting 45 Minute Dr.Metal 3'-0" 6'-8 " D002 DOOR SCHEDULE PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: SCH-2.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-SCH21 O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - S C H 2 1 A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions 54 Slope 1.6% 12.58 TC12.20 FS Finish Pad = 10.71 4" concrete2" sand4" gravel Concrete Garage Slab LOT 5 LOT 3 Alley Se a s h o r e D r i v e 1'- 6 " 15'-838" 69'-1112" 1'- 6 " 1'-6" 18' - 1 0 " 1'-6" 72'-8" 9'-512" 15' - 1 0 " 37'-4" 10'-1"14'-1"9'-6" 32'-712" 3'-9"7'-012"8'-6" B A4.1 GA4.3 E A4.2 A A4.1 1 2 735 D A4.2 F A4.3 C A4.1 4 678" 7" 5" 518" 3" 6" 16 ' - 1 0 " 914" 6'-658"15'-838"14'-1" 17' - 6 " 1'-5 12" 19 ' - 1 1 18" 1'-0" 1'-0" 1'-0"14'-258"2'-1"5'-538" 5'-1 0 " 3'-0 " 7'- 1 12"4'-434" 2'- 1 0 12" 434"6'-0" 9"4'-6"9"3'-538"2'-1"14'-258"1'-0"13'-7"1'-0" 9" 4'-4 " 9" 2'- 4 12" 6" 1'- 0 14" 3'- 1 12" 1'- 8 14" 5'-812" 3'-0" Curb Footingper Structural Curb Footing per Structural Crawl Space Garage Elevator Pit 12.30 FS 11.63 FS 11 58" 11.76 FS-GB 11.76 FS Carport 11.67 FSSlope1.1% 2% 2% 3.6% 12.51 TC12.07 FS 17.25 Top 13.10 FS 12.07 FS-GB 1.7% 2% 2% 13.92TC 14.72 FS 13.30 FS 13.67 FS 2% 2% 1.9%Swale FF= 17.25 Existing = (13.50) (Raised concrete over native sand) 13.02 FS Slope3.4% 11.76FS3'- 1 " 3'-1 " 3'-1"16'-11" 20'-0" 6'-0"7'-4" 1'- 0 " 2'-1 " 11.40 FS N52 46'30"E 79.33'Property Line N3 9 3 5 ' 3 0 " W 2 6 . 0 2 ' Pro p e r t y L i n e N52 46'30"E 54.46'Property Line N52 46'30"E 25.00' N39 35'30"W 1.00' Property Line N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' Pr o p e r t y L i n e 718" 1'-6"1'-6"1'-6"1'-212" 1'-612"4'-512"5'-012"2'-0"3'-812"4'-912" 1'- 6 " 1'- 6 " 6" 1'- 6 " 6" 6" 6" 438"578" 718" 1'-234" 1'-114"1134" 11'-418" 738"738" 558" 1'-1 1 78" 6 Cassionper Structural W10x77 HSS 5x5x1/4 W10x77 W10x77 W10x77 6"6" 314" 5516" 11316" 6"6" Line of Fireplace projection above 6"6" 718" 412" 6" 514" 6" 918"278" 538" 614" W10x30 918"278"614" 11 14" HSS 5x5x1/4 W10x30 1'-6 " 1"1'- 3 " 518"1'- 7 34" 1'- 1 " 1'- 0 34" 1'- 1 " 234" 438"578"478" 13.38 TC13.30 FS 13.38 TC 13.30 FS(13.3 NG) 2% 13.55 FS-GB 13.63 TC13.30 FS 12.97 FS13.05 TC 12.55 FS 12.58 TC 12.50 FS (12.4 NG)2.7%12.45 FS (12.07) NG 12.25 FS 12.63 TC12.55 FS S=2.9% 11.84 TC Slope0.8% Slope0.6% 11.84 TC12.57 TC12.07 FS 12.49 FS 2.3% Slope7.9% 11.27 TC 11.13 FS 11.36 TC11.17 FL Slope8% 19'-0" Minimum Interior clear dimension6" 13.18 TC 13.06 FS 4'-0" 12.04 FS Slope 3.7% S=1.4%S=1% (11.6) NG 3" 11.90 FS-GB (11.9) NG Slab Edge Plan SCALE: 1/4" = 1'-0" SLAB EDGE PLAN PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A1.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions SLOPE TO DRAIN SLOPE TO DRAIN 1/8" PERFOOT U.N.O. FINISH SLAB TO FINISH SLAB DIMENSION NOTE: REFER TOCIVIL DRAWINGS FORADDITIONAL SLAB ELEVATIONINFORMATION SLAB LEGEND 1. THIS ARCHITECTURAL FOUNDATION PLAN IS FOR DIMENSIONAL INFORMATION ONLY. THE CONTRACTOR SHALL REFER TO THE STRUCTURAL FOUNDATION PLAN FOR ALL STRUCTURAL REQUIREMENTS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IF THERE IS ANY DISCREPANCY BETWEEN THE ARCHITECTURAL FOUNDATION PLAN AND THE STRUCTURAL FOUNDATION PLAN. 2. FOOTINGS SHALL BE EXAMINED AND CERTIFIED IN WRITING BY THE PROJECT SOIL / GEOLOGY ENGINEER PRIOR TO EMA INSPECTIONS AND PLACEMENT OF CONCRETE. 3. VERIFY ALL INFORMATION REGARDING CONCRETE SLAB, FOUNDATION, AND RETAINING WALLS, WITH STRUCTURAL AND CIVIL ENGINEER'S DRAWINGS. SLAB NOTES 4. REFER TO STRUCTURAL DRAWINGS FOR SHEAR WALLS AND HOLD DOWN LOCATIONS AND SIZES. 5. DEPRESSED SLAB FOR MATERIAL THICKNESS REFER TO LEGEND. 6. PROVIDE ELECTRICAL CONDUIT BELOW SLAB FOR FLOOR OUTLETS, KITCHEN ISLAND OUTLETS AND APPLIANCES. VERIFY LOCATION WITH INTERIOR DESIGN DRAWINGS 7. SURVEYOUR TO FILE A CORNER RECORD OF SURVEY WITH THE OFFICE OF COUNTY SURVEYOR. EVIDENCE OF FILING SHALL BE SUBMITTED TO BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. 55 LOT 5 LOT 3 Alley Se a s h o r e D r i v e 35'-034" 918" Up 9R 20'-412"3'-9" 4'-7" 11 58" 5'-812" 13.10 11.17 FL11.67 11.13 FL 312" 1'-0" 4'- 5 " FS 75'-8" 26'-012" 16'-11" 55'-412"5'-812" 29'-4" 13'-7" 13'-7" 75'-8" 10'-10" 3'-712" 1'-0" 34'-1112" 1'-0" 35'-0" 19'-5" 2'-4" 1'- 5 12" 2'-6" 19 ' - 1 1 18" 17' - 6 " E.G. El. 13.50 19'-1012" 13.02FS FS (14.72) 11.27 TC11.63 11.36 TC11.76 FS 0.9% 2.3%Up 8R Up7R 7.9% 1.1% 8% 3.4% 3.4% 1.7% 11.76 FS(11.6) NG 0.6% FS 17.25 BreakawayLanding Exisisting Hardscapeto Remain FS FSUp7R B A4.1 G A4.3 E A4.2 A A4.1 13.30 FS Dn4R 1 2 7 14.70 FS 3 5 Up6R Crawl Space Garage D A4.2 FA4.3 C A4.1 4 3'- 7 " 16' - 1 0 " 678" 3'-3 12" 5'- 5 " 3'- 0 " 6'- 4 14" 914" 2'-314"4'-434" 3'-138"2'-1"14'-258" 6'-6 12" 812" 5'- 1 12" 4'-1012"3'-1038" 2'-4 78" 17'-6" x 19'-0" min.Parking Required 41 D001 Open Treads at 10.25" Each 49 38 22 47 48 312" 312"3'- 3 12" 3'- 0 " 812" 46 38 Unit A Unit B 6" 3'-0"2'-0" 5'-0" Setback 3'- 0 " Se t b a c k 4'-7"24'-9"5'-6" 3'-0 " Se t b a c k 1'-0 " 2'- 1 " 3'-0 " 1"5'-0"1'-0" 7'-4"6'-0" 2'-1" 6'-0"7'-012" FS (14.70) 13.67FS 13.55FS-GB 2% 2% 2% 2% 2% 6" 6" 434" 6" 12.07 FS-GB 12.63 FS 12.30 FS 2% 2% FS - GB 11.76 3'- 0 " Se t b a c k 11 . 7 6 F S 3'- 0 " Se t b a c k Dashed line Indicates 1 Hour Fire Resistance-Rated wall 14'-7" N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' Wall or floor between house Living area and garage shall be 5/8" type "X" Gyp. Bd. on garage side of wall or floor/ceiling. Rated separation must extend from floor level to roof sheathing. 1 3/4" thick self-closing & self-latching,tight fitting 45 minute rated door The entire Carport and Garageceiling shall be 5/8" type "X" Gyp. Bd. 1W1 1W1 N52 46'30"E 54.46'Property Line N39 35'30"W 1.00'Property Line N52 46'30"E 25.00' Pr o p e r t y L i n e N3 9 3 5 ' 3 0 " W 2 6 . 0 2 ' Pro p e r t y L i n e N52 46'30"E 79.33' Property Line 3'-0 " Se t b a c k Trash Binsbelow water heaters 1.9% 11 . 6 7 F S 718" 2'- 5 78"5516 "578"1'-234"438" 21316 " 5516 " 1'-234"578" 6 10 58" 1'-0"678" 718" 518" W10x77 W10X77 HSS5x5x1/4 Line of Fireplace projection above 1W11W5 Water Meter Duplex shall be serviced by separate Utilities (water & Gas) Duplex shall be servicedby separate Utilities(water & Gas) Gasmeters 412" 718" 6"6" 6"6" 1018"9" HSS5x5x1/4 W10x77 11 14" 614" 278"918" W10x306"6" W10x30 538" 614" 278"918"W10x77 518" 278" 1'-0" 514" 212" D002 D104 DoorAbove OpenTreadsstairs OpenTreadsstairs OpenTreads stairs OpenTreads stairs 11.84 TC 13.63 TC 13.30 FS 2% 13.38 TC13.30 FS TC 11.84 0.8% 19'-0" Minimum interior clear 17 ' - 6 " M i n i m u m i n t e r i o r c l e a r 3.7% 12.07 FS-GB 12.04 FS 12.04 FS 11.90 FS-GB Garage Level - Floor Plan SCALE: 1/4" = 1'-0" GARAGE LEVEL FLOOR PLAN PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A2.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 596 Sq.Ft. 262 Sq.Ft.Third Level Living 1,448 Sq.Ft.Total Living Total Building Area (Buildable Area) 1,438.33 Sq.Ft. x 2 = 2,876.66 Sq.Ft.Maximum Floor Area : 290 Sq.Ft. 870 Sq.Ft. Unit A Unit B 444 Sq.Ft. 880 Sq.Ft. 1,176 Sq.Ft. 262 Sq.Ft. 2,318 Sq.Ft. 2,762 Sq.Ft. Total max allowable 69 Sq.Ft.Second Level Deck 69 Sq.Ft. 388 Sq.Ft.Roof Level Deck 882 Sq.Ft. Total Roof Deck 1,085 Sq.Ft. Carport 275 Sq.Ft. 580 Sq.Ft. 99 Sq.Ft.Main Level Deck 35 Sq.Ft. 134 Sq.Ft. 529 Sq.Ft.556 Sq.Ft. 494 Sq.Ft. FLOOR PLAN KEY NOTES SYMBOLXX A Elevation Key D C B Interior 20. PROVIDE SMOOTH METAL DUCT FOR DRYER EXHAUSTEXTENDING TO OUTSIDE WITH BACKDRAFT DAMPER.PER CMC. 21. FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OTHERCOMPONENTS SHALL BE LISTED AND INSTALLED INACCORDANCE WITH THEIR LISTING AND MANUFACTURERINSTRUCTIONS. 22. DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THETERMINATION OF THE FACTORY-BUILT CHIMNEYS EXCEPTWHERE SUCH SHROUDS ARE LISTED AND LABELEDFOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEYSYSTEM AND ARE INSTALLED IN ACCORDANCE WITHMANUFACTURER'S INSTALLATION INSTRUCTION.CMC 802.5.2.4 GASEOUS FUEL BURNING PAN MUST BEPERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACEMUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDSMANDATORY MEASURES. 23. NET AREA OF SHOWER ENCLOSURES SHALL BE NOT LESSTHAN 1,024 Sq In (7.1 Sq. Ftt.) OF FLOOR AREA, AND A MINIMUMOF 30 INCH DIAMETER CIRCLE. PER CPC 408.6 24. HANDRAILS: a. HANDRAILS OTHER THAN CIRCULAR CROSS SECTIONS SHALL HAVE A PERIMETER DIMENSION OF 4 TO 6.25 INCHESWITH A MAXIMUM CROSS SECTION OF 2.25 INCHES. R311.7.8.3item 1 b. HANDRAILS WITH A PERIMETER GREATER THAN 6.25 INCHESSHALL COMPLY WITH R311.7.8.3 item 2. c. HANDRAILS SHALL BE CONTINUOUS WITHOUT INTERRUPTIONBY NEWEL POST OR OTHER OBSTRUCTION, EXCEPT AT THELANDING, VOLUTE OR TURNOUT ON LOWEST TREAD.R311.7.8.2 Exception 1&2. 1 LINE OF CABINET(S) ABOVE 2 CABINET(S) 3 BUILT-IN MILLWORK 4 KITCHEN ISLAND 5 PANTRY WITH SHELVES 6 24" FARM HOUSE SINK WITHGARBAGE DISPOSAL 7 30" FARM HOUSE SINK WITHGARBAGE DISPOSAL 8 24" GAS RANGE / OVENAS SELECTED BY OWNER 9 WOLF 36" GAS RANGE / OVENAS SELECTED BY OWNER 10 WOLF OVEN AS SELECTED BY OWNER 11 WOLF MICROWAVE OVEN ASSELECTED BY OWNER 12 VENT HOOD TO OUTSIDE AIR,MINIMUM EXHAUST RATE FOR THE KITCHEN RANGES SHALL FOLLOWTABLE 150.0-G. BEES 150(o) Exc. 5 TO150.2(a), & ASHRAE Std. 62,2.MINIMUM EXHAUST RATE FOR UNIT "A"IS 250 CFM AND FOR UNIT "B" IS 280 CFM.REFER TO TABLE 150.0-H ON SHEET A-6.1NOTE # 54 FOR MINIMUM DUCT SIZE.UNIT "A" WILL HAVE AN 8" DUCT,& UNIT "B" WILL HAVE AN 9" DUCT. 13A SUB-ZERO PRO REFRIGERATORSELECTED BY OWNER WALL LEGENDFLOOR PLAN NOTES 1. SMOKE DETECTORS SHALL BE INTERCONNECTED SUCHTHAT AT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALLALARMS. SMOKE DETECTORS SHALL BE "HARD WIRED" ANDSHALL BE EQUIPPED WITH A BATTERY BACK UP. CARBONMONOXIDE DETECTORS SHALL BE "HARD WIRED" ANDSHALL BE EQUIPPED WITH A BATTERY BACK UP.CRC R314 & CRC R315.3 2. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS ANDSIMILAR FIXTURES SHALL BE PROVIDED WITH ANEXHAUST FAN WITH A MINIMUM CAPACITY OF 50 cfmCBC 1203.4.2.1, CMC T4-4 3. SHOWERS AND TUB / SHOWERS SHALL BE PROVIDED WITHPRESSURE BALANCE OR THERMOSTATIC MIXING VALVECONTROLS. PER CPC. 4. WATER CLOSETS SHALL USE NO MORE THAN 1.28 GALLONSOF WATER PER FLUSH, LAVATORIES FAUCETSNO MORE THAN 1.5 GPM AT 60 PSI, KITCHENFAUCETS NO MORE THAN 1.8 GPM AT 60 PSI,SHOWER HEAD NO THAN 2 GPM, CGC SECTION 4.303 5. WHEN A SHOWER IS PROVIDED WITH MULTIPLE SHOWERHEADS, THE SUM OF FLOW TO ALL THE HEADS SHALL NOTEXCEED THE 20% REDUCED LIMIT, OR THE SHOWER SHALLBE DESIGNED SO THAT ONLY ONE HEAD IS ON AT A TIME.CGC 4.303.2 6. LANDSCAPE IRRIGATION WATER USE SHALL HAVEWEATHER BASED CONTROLLERS. CGC 4.304.1 7. PROVIDED WATER EFFICIENT LANDSCAPE IRRAGATIONDESIGN WHERE POTABLE WATER USE DOES NOT EXCEED65% OF THE ETo. (TIER 1) 8. A MINIMUM OF 50% OF CONSTRUCTION WASTE IS TO BERECYCLED. CGC 4.408.1 9. THE BUILDER IS TO PROVIDE AN OPERATION MANUAL(CONTAINING INFORMATION FOR MAINTAINING APPLIANCES,ETC.) FOR THE OWNER AT THE TIME OF FINAL INSPECTION.CGC 4.410.1 10. DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TOBE SEALED, AND MECHANICAL EQUIPMENT IS TO BECOVERED CGC 4.504.1 11. VOC'S MUST COMPLY WITH THE LIMITATIONS LISTED INSECTION 4.504.3 AND TABLES 4.504.1, 4.504.2, 4.504.3, AND4.504.5 FOR: ADHESIVES, PAINTS AND COATINGS, CARPETAND COMPOSITION WOOD PRODUCTS. CGC 4.504.2 12. THE MOISTURE CONTENT OF WOOD SHALL NOT EXCEED 19%BEFORE IT IS ENCLOSED IN CONSTRUCTION. THE MOISTURECONTENT NEEDS TO BE CERTIFIED BY ONE OF 3 METHODSSPECIFIED. BUILDING MATERIALS WITH VISIBLE SIGNS OFWATER DAMAGE SHOULD NOT BE USED IN CONSTRUCTION.THE MOISTURE CONTENT MUST BE DETERMINED BY THECONTRACTOR BY ONE OF THE METHODS LISTED IN CGCSECTION 4.505.3 13. BATHROOM FANS SHALL BE ENERGY STAR RATED, VENTEDDIRECTLY TO THE OUTSIDE AND CONTROLLED BY AHUMIDISTAT. CGC 4.506.1 14. IF PROVIDED, WHOLE HOUSE EXHAUST FANS SHALL HAVEINSULATED COVERS OR LOUVERS WHICH CLOSE THE FANIS OFF. THE COVERS OR LOUVERS SHALL HAVE MINIMUMR4.2 INSULATION. CGC 5.507.1 15. PROVIDE NON-REMOVABLE BACKFLOW PREVENTION DEVICES AT ALL EXTERIOR HOSE BIBS. PER CPC. 16. PROVIDE PRESSURE RELIEF VALVE WITH DRAIN TO OUTSIDEAT WATER HEATERS. PER CPC. 17. HEATING AND AC SHALL BE SIZED AND SELECTED BYACCA MANUAL J OR ASHRAE HANDBOOK OR EQUIVALENT.THE DUCT SHALL BE SIZED IN ACCORDANCE WIHT ONEOF THE ACCA METHODS LISTED IN CGC SECTION 4.507.2 18. PRIOR TO FINAL APPROVAL OF THE BUILDING LICENSEDCONTRACTOR, ARCHITECT OR ENGINEER IN RESPOSIBLECHARGE OF THE OVERALL CONSTRUCTION MUST COMPLETEAND SIGN THE GREEN BUILDING STANDARDS CERTIFICATIONFORM AND GIVEN TO THE BUILDING DEPARTMENT OFFICALTO BE FILED WITH THE APPROVED PLANS. 19. PROVIDE FIRE BLOCKS AND DRAFT STOPS IN THE WOODFRAME FLOOR CONSTRUCTION CONTAINING CONCEALEDSPACE WHERE THERE IS USABLE SPACE ABOVE AND BELOWTHE CONCEALED SPACE. SUCH DRAFT STOPS SHOULD BEINSTALLED SO THAT THE AREA OF THE CONCEALED SPACEDOES NOT EXCEED 1000 SQ. FT. DRAFTSTOPPING SHOULDDIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. PER CBC. 13B REFRIGERATOR SELECTED BY OWNER 14 DISHWASHER AS SELECTED BY OWNER 15 TRASH RECYCLING BIN 16A PREFABRICATED METAL FIREPLACE:BY:"ORTAL" MODEL ORTAL MINIMAL130 TRADITIONAL 42" GAS ONLYDIRECT VENT OR APPROVED EQUAL.INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODESANSI Z21.88/CSA 2.33 16B MASONRY FIREPLACE MANUFACTURESMASON-LITE MODEL MGFP-39 ORAPPROVED EQUAL. ICC REPORT ESR-2401TESTED AND LISTED BY PFS CORP., USAREPORT No. 08-154 16C PREFABRICATED METAL FIREPLACE:BY:EMPIRE COMFORT SYSTEMS,MODEL DVD42FP, GAS ONLY DIRECT-VENTOR APPROVED. INSTALL IN ACCORDANCEWITH THE MANUFACTURER'S PUBLISHEDINSTALLATION INSTRUCTIONS, ANDAPPLICABLE CODES. CERTIFIED INACCORDANCE WITH AMERICAN NATIONALSTANDARD/CSA STANDARDANSI Z221.88 / CSA 2.33 AND BYUNDERWRITERS LABORATORIES AS ADIRECT-VENT GAS FIREPLACE HEATER. 17 FIREPLACE HEARTH 18 EXTERIOR FINISH OPENING ONE HOUR CONSTRUCTION LOW WALL 2 X 6 STUD WALL 2 X 4 STUD WALL 2 X 8 STUD WALL 19 FLAT DRYWALL OPENING 20 FLAT CASED OPENING 21 DECORATIVE WOOD BEAMS 22 HANDRAIL 23 GUARDRAIL 24 LOW WALL 25 LOW LINEN 26 SHELF AND POLE 27 DOUBLE SHELF AND POLE 28 LAVATORY 29 PEDESTAL SINK 30 MUDSET CERAMIC TILE SEAT 31 HOT MOPPED SHOWER PAN WITH MUDSETCERAMIC TILED WAINSCOT TO 84" AFF W/PRESSURE BALANCE THERMOSTATICMIXING VALVE 32 BUILT-IN SOAP NICHE 33 TEMPERED GLASS SHOWER DOOR 34 WATER CLOSET TO BE 30" MIN WIDE WITH24" IN FRONT OF TOILET. LOW FLUSHTOILETS 1.28 GALLONS PER FLUSH 35 WASHER SPACE. PROVIDE RECESSED HOT ANDCOLD WATER BIBBS, PROVIDE FLOOR DRAIN. 36 DRYER SPACE. PROVIDE DRYER VENT TOOUTSIDE AIR PER CMC 37 STACKED WASHER & DRYER, PROVODECOLD WATER BIBBS, PROVIDE FLOOR DRAIN 38 INSTANTANEOUS TANKLESSWATER HEATER .94 EF / 199,000 Btu/hr 39 MECHANICAL EQUIPMENT 40 ATTIC ACCESS 41 LINE OF FLOOR ABOVE 42 DECK DRAIN & OVERFLOW 43 ROOF DRAIN 44 BUILT-UP ROOFING AT MECHANICAL WELL 45 MOUNTED AC UNITREFER TO MECHANICAL PLANS 46 ELEVATOR MODEL LLT-950 (TRACTION)HOR HP4 MG 12 RH RAIL, FRONT/REAROPENINGS BY RESIDENTIAL ELEVATOR INC.OR APPROVED EQUAL, ELEVATOR SHAFTBELOW DESIGN FLOOD ELEVATIONSHALL COMPLY WITH ASCE 24-14 SEC. 7.5ASME/ANSI A17.1 NATIONAL SAFETY CODESFOR ELEVATORS SECTION 5.3 47 CONCRETE GARAGE FLOOR 48 CONCRETE DRIVEWAY 49 BREAKAWAY WALL 50 DRYER EXHAUST VENT TO OUTSIDE AIR, DUCTSHALL TERMINATE NO LESS THAN 3'-0" FEETFROM OPENINGS INTO THE BUILDING.(502.2.1 CMC) REINFORCEMENT FOR GRAB BARS - R327.1.1 AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BEPROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCEWITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THEENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH THISSECTION. 1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHERCONSTRUCTION MATERIALS APPROVED BY THE ENFORCINGAGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCHNOMINAL LUMBER, [1 1/2" INCH BY 7 1/4" ACTUAL DIMENSION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUALHEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BELOCATED BETWEEN 32" INCHES AND 39 1/4" INCHES ABOVETHE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. 3. WATER CLOSET REINFORCEMENT SHALL BE INSTALL ONBOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALLAND THE BACK WALL. 4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHEREWALL FRAMING IS PROVIDED. 5. BATHTUB AND COMBINATION BATHTUB/SHOWERREINFORCEMENT SHALL BE CONTINUOUS ON EACH END OFTHE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACKWALL REINFORCEMENT FOR A LOW GRAB BAR SHALL BEPROVIDED WITH THE BOTTOM EDGE LOCATED NO MORETHAN 6" INCHES ABOVE THE BATHTUB RIM. EXCEPTIONS: 1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO ASIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THEBATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OFFLOOR MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRABBAR REINFORCEMENTS APPROVED BY THE ENFORCINGAGENCY. 2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALLFRAMING FOR PRE-FABRICATED SHOWER ENCLOSURESAND BATHTUB WALL PANELS WITH INTEGRAL FACTORY-INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLEDREINFORCEMENT FOR GRAB BARS IS PROVIDED. 3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATIONOF REINFORCEMENT AND/OR GRAB BARS SHALL BEPERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATIONOF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATEMETHOD IS APPROVED BY THE ENFORCING AGENCY. 4. BATHTUBS WITH NO SURROUNDING WALLS , OR WHEREWALL PANELS DO NOT PERMIT THE INSTALLATION OFREINFORCEMENT SHALL BE PERMITTED, PROVIDEDREINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTEDGRAB BARS ADJACENT TO THE BATHTUB ON AN ALTERNATEMETHOD IS APPROVED BY THE ENFORCING AGENCY. 5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FORBATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETESLAB FLOORS. DOCUMENTATION FOR GRAB BAR REINFORCEMENT - R327.1.1.1 INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCAIONOF THE GRAB BAR REINFORCEMENT SHALL BE PLACED IN THEOPERATION AND MAINTENANCE MANUAL IN ACCORDANCE WITHTHE CALIFORNIA GREEN BUILDING STANDARDS CODE.SECTION 4.410.1. SOUND TRANSMISSION CONTROL NOTES 1. SOUND INSULATION NOTES:a. APPROVED ACOUSTICAL SEALANT SHALL BEPROVIDED ALONG THE JOINT BETWEEN THE FLOORAND THE SEPARATION WALL.b. ALL PENETRATIONS INTO SOUND-RATED PARTITIONSOF FLOOR-CEILING ASSEMBLIES SHALL BE SEALEDWITH AN APPROVED PERMANENT RESILIENTSEALANT.c. ALL RIGID CONDUIT, DUCTS, PLUMBING PIPES,AND APPLIANCE VENTS LOCATED IN SOUNDASSEMBLIES SHALL BE ISOLATED FROM THEBUILDING CONSTRUCTION BY MEANS OF RESILIENTSLEEVES, MOUNTS, OR MINIMUM 1/4" THICKAPPROVED RESILIENT MATERIAL.EXCEPTION: GAS PIPING NEED NOT BE ISOLATED.d. METAL VENTILATING AND CONDITIONED AIR DUCTSLOCATED IN SOUND ASSEMBLIES SHALL BE LINED.e. MINERAL FIBER INSULATION SHALL BE INSTALLEDIN JOIST SPACES TO A POINT 12" BEYOND THE PIPEOR DUCT, WHENEVER A PLUMBING PIPE OR DUCTPENETRATES A FLOOR-CEILING ASSEMBLY OR WHERESUCH UNIT PASSES THROUGH THE PLANE OF THEFLOOR-CEILING WITHIN A WALL. 2. A SOUND TRANSMISSION CLASS (STC) RATING OF NOT LESSTHAN 50 BASED ON LAVATORY TESTING (45 IF FIELD TESTED)IS REQUIRE (NBMC 15.05.203, CBC 1206.2) 3. A SOUND TRANSMISSION CLASS (STC) RATING ANDIMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN50 BASED ON LABORATORY TESTING (45 IF FIELD TESTED)IS REQUIRED. (NBMC 15.05.230, CBC 1206.2, 1206.30) LINE INDICATESMINIMUM 0.5-HOURFIRE-RESISTANCE-RATED SINGLE WALL LINE INDICATES THE MINIMUM 1-HOURFIRE-RATED WALL 1W1 LINE INDICATESMINIMUM 0.5-HOURFIRE-RESISTANCE-RATED DOUBLE WALL 1W2 1W3 LINE INDICATES OCCUPANCYSEPARATION WALL 1W5 LINE INDICATES THEMINIMUM 1-HOUR FIRE-RATED LOW WALL 1W4 REFER TO T-24 SHEETS FOR CF1R FORMS AND COMPLIANCE INFORMATION INSULATION SCHEDULE BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.32 U-factor, 0.23 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.23 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-30 (2x4) plus R-15 (2x4) below roof deckRoof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 10.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storag: 5kWh; 95% charging/discharging BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-38 (2x4) Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 9.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storage: 5kWh; 95% charging/discharging Unit "A"Unit "B" NOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL 56 N52 46'30"E 54.46' N3 9 3 5 ' 3 0 " W 2 6 . 0 2 ' N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' LOT 5 LOT 3 N52 46'30"E 79.33' Alley Se a s h o r e D r i v e 6'-0" 75'-8" Dn9R Up17R 5'-812" 4'-112" 75'-8" 7'-9" Pdr 4'-112" 2'-6"10'-112" 11'-4"3'-9" 35'-512" 20'-412" 3'-712" 7'-012"2'-10" 4'-1012" 8'-6" 3'-2" FS 13'-4" 3'-3 12" 10'-112" 5'-212" Dine Entry Unit "A" Kitchen 3'-3"3'-912" F.F. El. 17.25 F.S. El. 17.00 Deck (13.30) Dn4R FS 3'-3" 4'-9"6'-7" 3'-0" (14.72) FS 13.10 FS 17.25 BreakawayLanding Exisisting Hardscape to Remain NO NEW IMPROVEMENTS PLANNED FOR THE OCEANFRONT ENCROACHMENT AREA FS 14.72 Dn8R Dn7R Ba 4 Dn 7R pantry FS 16.84 Dn5R Up14R 34'-6" 10'-7"25'-012" 8'-4" 5'-0" 9'-412" 3'-712" 1'-4" 7'-912" 4'-9"6'-5" 4'-8" 2'-912" 4'-812" 22'-3"12'-3" 10" 3'-1012"7'-6" 11 ' - 1 0 " 7'- 0 " Bed 3 6'- 2 " 4'-2" 18 ' - 1 0 " Kit 10 " Family F.F. El. 20.01 19.73FS 30'-11" B A4.1 G A4.3 E A4.2 A A4.1 1 2 735 D A4.2 FA4.3 C A4.1 4 17.36FS 5'-3"8'-3"2'-734"3'-414"10'-112" 4'-0 " 1'- 1 12" 3'- 1 12" 512" 3'-8 12" 3'-9 " 1'-4 12" 1'-3"1'-3"3'-5"3'- 1 12" 2" 1'-9" 1'- 1 0 14" 1'-11"2'-9"3'-812" 3'- 3 12" 2'-0 " 3'-5 " 1'-112" 7'- 0 12" 2'-1 1 " 5'- 0 " 5" 3'-0 " 312" 3'- 3 12" 512" 2" 10' - 3 " 512" 3'-514" 3'-312"2'-614"3'-512"1'-234" 3'-1 0 " 3'- 0 " 3'-7 " 3'- 3 14" 914" 3'- 0 34" 3'- 1 " 3'-8" (7) 12"Open Treads 1'- 6 12"1'-6 12" 3'-934"4'-412"6'-5"6'-0"6'-5"11"1'-7"3'-0" 1'- 7 34" 3'- 2 34" 2'- 1 12" 2'-3"2'-9" W112 W111 W108W107W103W103W102 W101 W101 W105 W106 W109 W110 W110 W113 6'- 0 34" 5'-9 14" D110 D109 D108 D107 D106 D104 D101 D105 D102 16A 144 7 15 391221 1'-0 " 1'- 5 12" 712"34 3 3034282 33 Fully adhered waterproofDeck membrane ICCESR-2701 "Life Deck AL" over sloped EPS deck System ICC ESR-1962 Slope2% 22 1/2" Gyp. board understairs and enclosed side of walls 3113A D103 412"3'-1" 3'-11" 5 6'- 7 34" 2'- 1 12" 214" 2'- 6 12" 2'-712"1'-112"2'-234" Treads at10.25" Each Open Treads at10.25" Each 46 22 Fully adhered waterproofDeck membrane ICCESR-2701 "Life Deck AL"over sloped EPS deck System ICC ESR-1962 23 18 ' - 1 0 " Op e n Tre a d s a t 12 " E a c h 23 6'- 6 34" 1114" (6) 12" OpenTreads (5) 11"Open Treads (6) 11"Open Treads (3) 11"Treads 11" Slope2% 4'-212" 2" 5'-612" 23 5'- 4 " 4'-1 1 12" 4'- 4 12" 13B 8 12 4 6 14 4'-1134"2'-6" 5'-4" 28 2 2322 15 1 2 2223 W104 10 11 Unit "B" 3'- 0 " 1'-112" 3'-6"4'-512"4'-512" 5'-1 1 12" 2'- 0 " 6" 1'- 5 58" 1'- 3 " 8'- 2 " 8'- 2 " 1'- 3 " 1'-7" SittingBenchSittingBench 10 1316 " 558"558" 558" 3 3 2'- 1 " 3'- 0 " Se t b a c k 40 Bathroom at Entry level shall be provided with reinforcementfor grab bars 1'- 1 " 2'- 0 " 1" 1'-0 " 3'- 1 " 3'- 1 " 3'- 1 " 3'- 1 " 3'- 0 " Se t b a c k 2'-0" 5'-0" Setback 3'-0 " Se t b a c k 3'- 0 " Se t b a c k Line ofFireplaceabove 1W2 Dashed line Indicates 1 Hour Fire Rated wall 1W3 Property Line Property Line Pro p e r t y L i n e Pr o p e r t y L i n e 1W1 1W1 1W1 1W1 N52 46'30"E 25.00' N39 35'30"W 1.00'Property Line Dashed line Indicates 1 Hour Fire Resistance-Rated wall FS 12.60 6 W10x77 W10x77 61316" 61316" 10 1316 " 42 42 W111 Dn 6R Dn3R Main Level - Floor Plan SCALE: 1/4" = 1'-0" MAIN LEVEL FLOOR PLAN PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A2.2 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 596 Sq.Ft. 262 Sq.Ft.Third Level Living 1,448 Sq.Ft.Total Living Total Building Area (Buildable Area) 1,438.33 Sq.Ft. x 2 = 2,876.66 Sq.Ft.Maximum Floor Area : 290 Sq.Ft. 870 Sq.Ft. Unit A Unit B 444 Sq.Ft. 880 Sq.Ft.1,176 Sq.Ft. 262 Sq.Ft. 2,318 Sq.Ft. 2,762 Sq.Ft. Total max allowable 69 Sq.Ft.Second Level Deck 69 Sq.Ft. 388 Sq.Ft.Roof Level Deck 882 Sq.Ft. Total Roof Deck 1,085 Sq.Ft. Carport 275 Sq.Ft. 580 Sq.Ft. 99 Sq.Ft.Main Level Deck 35 Sq.Ft. 134 Sq.Ft. 529 Sq.Ft.556 Sq.Ft. 494 Sq.Ft. FLOOR PLAN KEY NOTES SYMBOLXX A Elevation Key D C B Interior 20. PROVIDE SMOOTH METAL DUCT FOR DRYER EXHAUSTEXTENDING TO OUTSIDE WITH BACKDRAFT DAMPER.PER CMC. 21. FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OTHERCOMPONENTS SHALL BE LISTED AND INSTALLED INACCORDANCE WITH THEIR LISTING AND MANUFACTURERINSTRUCTIONS. 22. DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THETERMINATION OF THE FACTORY-BUILT CHIMNEYS EXCEPTWHERE SUCH SHROUDS ARE LISTED AND LABELEDFOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEYSYSTEM AND ARE INSTALLED IN ACCORDANCE WITHMANUFACTURER'S INSTALLATION INSTRUCTION.CMC 802.5.2.4 GASEOUS FUEL BURNING PAN MUST BEPERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACEMUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDSMANDATORY MEASURES. 23. NET AREA OF SHOWER ENCLOSURES SHALL BE NOT LESSTHAN 1,024 Sq In (7.1 Sq. Ftt.) OF FLOOR AREA, AND A MINIMUMOF 30 INCH DIAMETER CIRCLE. PER CPC 408.6 24. HANDRAILS: a. HANDRAILS OTHER THAN CIRCULAR CROSS SECTIONS SHALL HAVE A PERIMETER DIMENSION OF 4 TO 6.25 INCHESWITH A MAXIMUM CROSS SECTION OF 2.25 INCHES. R311.7.8.3item 1 b. HANDRAILS WITH A PERIMETER GREATER THAN 6.25 INCHESSHALL COMPLY WITH R311.7.8.3 item 2. c. HANDRAILS SHALL BE CONTINUOUS WITHOUT INTERRUPTIONBY NEWEL POST OR OTHER OBSTRUCTION, EXCEPT AT THELANDING, VOLUTE OR TURNOUT ON LOWEST TREAD.R311.7.8.2 Exception 1&2. 1 LINE OF CABINET(S) ABOVE 2 CABINET(S) 3 BUILT-IN MILLWORK 4 KITCHEN ISLAND 5 PANTRY WITH SHELVES 6 24" FARM HOUSE SINK WITHGARBAGE DISPOSAL 7 30" FARM HOUSE SINK WITHGARBAGE DISPOSAL 8 24" GAS RANGE / OVENAS SELECTED BY OWNER 9 WOLF 36" GAS RANGE / OVENAS SELECTED BY OWNER 10 WOLF OVEN AS SELECTED BY OWNER 11 WOLF MICROWAVE OVEN ASSELECTED BY OWNER 12 VENT HOOD TO OUTSIDE AIR,MINIMUM EXHAUST RATE FOR THE KITCHEN RANGES SHALL FOLLOWTABLE 150.0-G. BEES 150(o) Exc. 5 TO150.2(a), & ASHRAE Std. 62,2.MINIMUM EXHAUST RATE FOR UNIT "A"IS 250 CFM AND FOR UNIT "B" IS 280 CFM.REFER TO TABLE 150.0-H ON SHEET A-6.1NOTE # 54 FOR MINIMUM DUCT SIZE.UNIT "A" WILL HAVE AN 8" DUCT,& UNIT "B" WILL HAVE AN 9" DUCT. 13A SUB-ZERO PRO REFRIGERATORSELECTED BY OWNER WALL LEGENDFLOOR PLAN NOTES 1. SMOKE DETECTORS SHALL BE INTERCONNECTED SUCHTHAT AT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALLALARMS. SMOKE DETECTORS SHALL BE "HARD WIRED" ANDSHALL BE EQUIPPED WITH A BATTERY BACK UP. CARBONMONOXIDE DETECTORS SHALL BE "HARD WIRED" ANDSHALL BE EQUIPPED WITH A BATTERY BACK UP.CRC R314 & CRC R315.3 2. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS ANDSIMILAR FIXTURES SHALL BE PROVIDED WITH ANEXHAUST FAN WITH A MINIMUM CAPACITY OF 50 cfmCBC 1203.4.2.1, CMC T4-4 3. SHOWERS AND TUB / SHOWERS SHALL BE PROVIDED WITHPRESSURE BALANCE OR THERMOSTATIC MIXING VALVECONTROLS. PER CPC. 4. WATER CLOSETS SHALL USE NO MORE THAN 1.28 GALLONSOF WATER PER FLUSH, LAVATORIES FAUCETSNO MORE THAN 1.5 GPM AT 60 PSI, KITCHENFAUCETS NO MORE THAN 1.8 GPM AT 60 PSI,SHOWER HEAD NO THAN 2 GPM, CGC SECTION 4.303 5. WHEN A SHOWER IS PROVIDED WITH MULTIPLE SHOWERHEADS, THE SUM OF FLOW TO ALL THE HEADS SHALL NOTEXCEED THE 20% REDUCED LIMIT, OR THE SHOWER SHALLBE DESIGNED SO THAT ONLY ONE HEAD IS ON AT A TIME.CGC 4.303.2 6. LANDSCAPE IRRIGATION WATER USE SHALL HAVEWEATHER BASED CONTROLLERS. CGC 4.304.1 7. PROVIDED WATER EFFICIENT LANDSCAPE IRRAGATIONDESIGN WHERE POTABLE WATER USE DOES NOT EXCEED65% OF THE ETo. (TIER 1) 8. A MINIMUM OF 50% OF CONSTRUCTION WASTE IS TO BERECYCLED. CGC 4.408.1 9. THE BUILDER IS TO PROVIDE AN OPERATION MANUAL(CONTAINING INFORMATION FOR MAINTAINING APPLIANCES,ETC.) FOR THE OWNER AT THE TIME OF FINAL INSPECTION.CGC 4.410.1 10. DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TOBE SEALED, AND MECHANICAL EQUIPMENT IS TO BECOVERED CGC 4.504.1 11. VOC'S MUST COMPLY WITH THE LIMITATIONS LISTED INSECTION 4.504.3 AND TABLES 4.504.1, 4.504.2, 4.504.3, AND4.504.5 FOR: ADHESIVES, PAINTS AND COATINGS, CARPETAND COMPOSITION WOOD PRODUCTS. CGC 4.504.2 12. THE MOISTURE CONTENT OF WOOD SHALL NOT EXCEED 19%BEFORE IT IS ENCLOSED IN CONSTRUCTION. THE MOISTURECONTENT NEEDS TO BE CERTIFIED BY ONE OF 3 METHODSSPECIFIED. BUILDING MATERIALS WITH VISIBLE SIGNS OFWATER DAMAGE SHOULD NOT BE USED IN CONSTRUCTION.THE MOISTURE CONTENT MUST BE DETERMINED BY THECONTRACTOR BY ONE OF THE METHODS LISTED IN CGCSECTION 4.505.3 13. BATHROOM FANS SHALL BE ENERGY STAR RATED, VENTEDDIRECTLY TO THE OUTSIDE AND CONTROLLED BY AHUMIDISTAT. CGC 4.506.1 14. IF PROVIDED, WHOLE HOUSE EXHAUST FANS SHALL HAVEINSULATED COVERS OR LOUVERS WHICH CLOSE THE FANIS OFF. THE COVERS OR LOUVERS SHALL HAVE MINIMUMR4.2 INSULATION. CGC 5.507.1 15. PROVIDE NON-REMOVABLE BACKFLOW PREVENTION DEVICES AT ALL EXTERIOR HOSE BIBS. PER CPC. 16. PROVIDE PRESSURE RELIEF VALVE WITH DRAIN TO OUTSIDEAT WATER HEATERS. PER CPC. 17. HEATING AND AC SHALL BE SIZED AND SELECTED BYACCA MANUAL J OR ASHRAE HANDBOOK OR EQUIVALENT.THE DUCT SHALL BE SIZED IN ACCORDANCE WIHT ONEOF THE ACCA METHODS LISTED IN CGC SECTION 4.507.2 18. PRIOR TO FINAL APPROVAL OF THE BUILDING LICENSEDCONTRACTOR, ARCHITECT OR ENGINEER IN RESPOSIBLECHARGE OF THE OVERALL CONSTRUCTION MUST COMPLETEAND SIGN THE GREEN BUILDING STANDARDS CERTIFICATIONFORM AND GIVEN TO THE BUILDING DEPARTMENT OFFICALTO BE FILED WITH THE APPROVED PLANS. 19. PROVIDE FIRE BLOCKS AND DRAFT STOPS IN THE WOODFRAME FLOOR CONSTRUCTION CONTAINING CONCEALEDSPACE WHERE THERE IS USABLE SPACE ABOVE AND BELOWTHE CONCEALED SPACE. SUCH DRAFT STOPS SHOULD BEINSTALLED SO THAT THE AREA OF THE CONCEALED SPACEDOES NOT EXCEED 1000 SQ. FT. DRAFTSTOPPING SHOULDDIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. PER CBC. 13B REFRIGERATOR SELECTED BY OWNER 14 DISHWASHER AS SELECTED BY OWNER 15 TRASH RECYCLING BIN 16A PREFABRICATED METAL FIREPLACE:BY:"ORTAL" MODEL ORTAL MINIMAL130 TRADITIONAL 42" GAS ONLYDIRECT VENT OR APPROVED EQUAL.INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODESANSI Z21.88/CSA 2.33 16B MASONRY FIREPLACE MANUFACTURESMASON-LITE MODEL MGFP-39 ORAPPROVED EQUAL. ICC REPORT ESR-2401TESTED AND LISTED BY PFS CORP., USAREPORT No. 08-154 16C PREFABRICATED METAL FIREPLACE:BY:EMPIRE COMFORT SYSTEMS,MODEL DVD42FP, GAS ONLY DIRECT-VENTOR APPROVED. INSTALL IN ACCORDANCEWITH THE MANUFACTURER'S PUBLISHEDINSTALLATION INSTRUCTIONS, ANDAPPLICABLE CODES. CERTIFIED INACCORDANCE WITH AMERICAN NATIONALSTANDARD/CSA STANDARDANSI Z221.88 / CSA 2.33 AND BYUNDERWRITERS LABORATORIES AS ADIRECT-VENT GAS FIREPLACE HEATER. 17 FIREPLACE HEARTH 18 EXTERIOR FINISH OPENING ONE HOUR CONSTRUCTION LOW WALL 2 X 6 STUD WALL 2 X 4 STUD WALL 2 X 8 STUD WALL 19 FLAT DRYWALL OPENING 20 FLAT CASED OPENING 21 DECORATIVE WOOD BEAMS 22 HANDRAIL 23 GUARDRAIL 24 LOW WALL 25 LOW LINEN 26 SHELF AND POLE 27 DOUBLE SHELF AND POLE 28 LAVATORY 29 PEDESTAL SINK 30 MUDSET CERAMIC TILE SEAT 31 HOT MOPPED SHOWER PAN WITH MUDSETCERAMIC TILED WAINSCOT TO 84" AFF W/PRESSURE BALANCE THERMOSTATICMIXING VALVE 32 BUILT-IN SOAP NICHE 33 TEMPERED GLASS SHOWER DOOR 34 WATER CLOSET TO BE 30" MIN WIDE WITH24" IN FRONT OF TOILET. LOW FLUSHTOILETS 1.28 GALLONS PER FLUSH 35 WASHER SPACE. PROVIDE RECESSED HOT ANDCOLD WATER BIBBS, PROVIDE FLOOR DRAIN. 36 DRYER SPACE. PROVIDE DRYER VENT TOOUTSIDE AIR PER CMC 37 STACKED WASHER & DRYER, PROVODECOLD WATER BIBBS, PROVIDE FLOOR DRAIN 38 INSTANTANEOUS TANKLESSWATER HEATER .94 EF / 199,000 Btu/hr 39 MECHANICAL EQUIPMENT 40 ATTIC ACCESS 41 LINE OF FLOOR ABOVE 42 DECK DRAIN & OVERFLOW 43 ROOF DRAIN 44 BUILT-UP ROOFING AT MECHANICAL WELL 45 MOUNTED AC UNITREFER TO MECHANICAL PLANS 46 ELEVATOR MODEL LLT-950 (TRACTION)HOR HP4 MG 12 RH RAIL, FRONT/REAROPENINGS BY RESIDENTIAL ELEVATOR INC.OR APPROVED EQUAL, ELEVATOR SHAFTBELOW DESIGN FLOOD ELEVATIONSHALL COMPLY WITH ASCE 24-14 SEC. 7.5ASME/ANSI A17.1 NATIONAL SAFETY CODESFOR ELEVATORS SECTION 5.3 47 CONCRETE GARAGE FLOOR 48 CONCRETE DRIVEWAY 49 BREAKAWAY WALL 50 DRYER EXHAUST VENT TO OUTSIDE AIR, DUCTSHALL TERMINATE NO LESS THAN 3'-0" FEETFROM OPENINGS INTO THE BUILDING.(502.2.1 CMC) REINFORCEMENT FOR GRAB BARS - R327.1.1 AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BEPROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCEWITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THEENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH THISSECTION. 1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHERCONSTRUCTION MATERIALS APPROVED BY THE ENFORCINGAGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCHNOMINAL LUMBER, [1 1/2" INCH BY 7 1/4" ACTUAL DIMENSION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUALHEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BELOCATED BETWEEN 32" INCHES AND 39 1/4" INCHES ABOVETHE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. 3. WATER CLOSET REINFORCEMENT SHALL BE INSTALL ONBOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALLAND THE BACK WALL. 4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHEREWALL FRAMING IS PROVIDED. 5. BATHTUB AND COMBINATION BATHTUB/SHOWERREINFORCEMENT SHALL BE CONTINUOUS ON EACH END OFTHE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACKWALL REINFORCEMENT FOR A LOW GRAB BAR SHALL BEPROVIDED WITH THE BOTTOM EDGE LOCATED NO MORETHAN 6" INCHES ABOVE THE BATHTUB RIM. EXCEPTIONS: 1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO ASIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THEBATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OFFLOOR MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRABBAR REINFORCEMENTS APPROVED BY THE ENFORCINGAGENCY. 2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALLFRAMING FOR PRE-FABRICATED SHOWER ENCLOSURESAND BATHTUB WALL PANELS WITH INTEGRAL FACTORY-INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLEDREINFORCEMENT FOR GRAB BARS IS PROVIDED. 3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATIONOF REINFORCEMENT AND/OR GRAB BARS SHALL BEPERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATIONOF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATEMETHOD IS APPROVED BY THE ENFORCING AGENCY. 4. BATHTUBS WITH NO SURROUNDING WALLS , OR WHEREWALL PANELS DO NOT PERMIT THE INSTALLATION OFREINFORCEMENT SHALL BE PERMITTED, PROVIDEDREINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTEDGRAB BARS ADJACENT TO THE BATHTUB ON AN ALTERNATEMETHOD IS APPROVED BY THE ENFORCING AGENCY. 5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FORBATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETESLAB FLOORS. DOCUMENTATION FOR GRAB BAR REINFORCEMENT - R327.1.1.1 INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCAIONOF THE GRAB BAR REINFORCEMENT SHALL BE PLACED IN THEOPERATION AND MAINTENANCE MANUAL IN ACCORDANCE WITHTHE CALIFORNIA GREEN BUILDING STANDARDS CODE.SECTION 4.410.1. SOUND TRANSMISSION CONTROL NOTES 1. SOUND INSULATION NOTES:a. APPROVED ACOUSTICAL SEALANT SHALL BEPROVIDED ALONG THE JOINT BETWEEN THE FLOORAND THE SEPARATION WALL.b. ALL PENETRATIONS INTO SOUND-RATED PARTITIONSOF FLOOR-CEILING ASSEMBLIES SHALL BE SEALEDWITH AN APPROVED PERMANENT RESILIENTSEALANT.c. ALL RIGID CONDUIT, DUCTS, PLUMBING PIPES,AND APPLIANCE VENTS LOCATED IN SOUNDASSEMBLIES SHALL BE ISOLATED FROM THEBUILDING CONSTRUCTION BY MEANS OF RESILIENTSLEEVES, MOUNTS, OR MINIMUM 1/4" THICKAPPROVED RESILIENT MATERIAL.EXCEPTION: GAS PIPING NEED NOT BE ISOLATED.d. METAL VENTILATING AND CONDITIONED AIR DUCTSLOCATED IN SOUND ASSEMBLIES SHALL BE LINED.e. MINERAL FIBER INSULATION SHALL BE INSTALLEDIN JOIST SPACES TO A POINT 12" BEYOND THE PIPEOR DUCT, WHENEVER A PLUMBING PIPE OR DUCTPENETRATES A FLOOR-CEILING ASSEMBLY OR WHERESUCH UNIT PASSES THROUGH THE PLANE OF THEFLOOR-CEILING WITHIN A WALL. 2. A SOUND TRANSMISSION CLASS (STC) RATING OF NOT LESSTHAN 50 BASED ON LAVATORY TESTING (45 IF FIELD TESTED)IS REQUIRE (NBMC 15.05.203, CBC 1206.2) 3. A SOUND TRANSMISSION CLASS (STC) RATING ANDIMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN50 BASED ON LABORATORY TESTING (45 IF FIELD TESTED)IS REQUIRED. (NBMC 15.05.230, CBC 1206.2, 1206.30) LINE INDICATESMINIMUM 0.5-HOURFIRE-RESISTANCE-RATED SINGLE WALL LINE INDICATES THE MINIMUM 1-HOURFIRE-RATED WALL 1W1 LINE INDICATESMINIMUM 0.5-HOURFIRE-RESISTANCE-RATED DOUBLE WALL 1W2 1W3 LINE INDICATES OCCUPANCYSEPARATION WALL 1W5 LINE INDICATES THEMINIMUM 1-HOUR FIRE-RATED LOW WALL 1W4 REFER TO T-24 SHEETS FOR CF1R FORMS AND COMPLIANCE INFORMATION INSULATION SCHEDULE BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.32 U-factor, 0.23 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.23 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-30 (2x4) plus R-15 (2x4) below roof deckRoof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 10.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storag: 5kWh; 95% charging/discharging BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-38 (2x4)Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 9.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storage: 5kWh; 95% charging/discharging Unit "A"Unit "B" NOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL 57 LOT 5 LOT 3 Alley Se a s h o r e D r i v e 75'-8" 312"312"4'-7" 4'-8 12" Dn 17R Up 15R 15'-7" 3'-8" 31'-412" 3'-8" 19'-112" 7'-11" 12'-3" 12'-7" 3'-7" 3'-8"12'-512" 34'-6" 4'-3" 7'-712" 5'-0" 11"11'-4"7'-912" 75'-8" 10'-7" 3'-712" 2'-2" Master Suite 2'-912" 4'-2" 10'-2" 4'-2" 6'-112" 15'-7"18'-11" 2'-8" 21'-212" 4'-312"3'-112"1'-612"3'-912"3'-712"7'-2" 4'- 2 " 12'-212"9'-0" 3'-2" 7'- 0 " 18 ' - 1 0 " 5'-9" 11 ' - 1 0 " Ba 2 Ma Bath Bed 2 Wic F.F. El. 27.24 3'-912"3'-10" 3'-0" Dn 14R Ma Bedroom open to below Ma Bath F.F. El. 28.96 Attic 3'-10"4'-912" 2'-1 0 " 5'- 3 " 4'-2 " 2'-5 " Up14R B A4.1 G A4.3 E A4.2 A A4.1 1 2 735 D A4.2 FA4.3 C A4.1 4 23 Fully adhered waterproofDeck membrane ICCESR-2701 "Life Deck AL"over sloped EPS deck System ICC ESR-1962 4'-212"6'-1"7'-812"4'-1012" 1'-7" 9'-5 " 18 ' - 1 0 " 9'- 5 " 1'-3"1'-2" 2'-5"4'-6"3'-3" 1'-0 " 4'-6 " 3'- 6 " 1'- 6 " 3'- 2 " 6'- 2 " 512"11'-4" 1'-4 " 1'-4 " 1'- 5 " 4'- 9 " 1'-1012"2'-4"2'-812"2'-1" 4'-0"5'-0" 4'-1012"3'-9" 3'-7 " 2'- 7 " 1'-1 0 12" 9'-3" 1'-3"1'-3" 2'- 1 1 " 6'- 7 " 2'-1"1'-2" 2'- 1 1 " 712" 2'- 4 " 2" 3'- 5 12" 5'- 1 1 12" 3'- 6 12"3'- 6 12" 3'- 3 12" 3'- 3 12" 3'-112"6'-314"3'-312"512" 2" 1'- 9 " 3'- 5 12" 3'- 4 " 8" 3'-3 12" 512"3'-112" 2'-10"312" 3'- 2 " 8'-712" 4'-234"512"6'-134"2'-1112"6'-10" 6'-0"9'-1114" 11 ' - 8 12" 3'- 4 12" 2" 2'- 1 1 " 8'-9 12" 512" 3'- 5 12" 3'- 1 12" 3'-7" 3'-514" 4" 3'-1112"1'-512" 4'-314" Treads at10.25" Each Treads at10.25" Each 4'-512"1'-1" 15'-112" 2" 3'-7 " 8'- 3 12" 3'- 3 " 3'-8 12" 2" 3'-134"9'-434"3'-912"3'-11"3'-912" Treads at10.5" Each D212 D211 D209 D213 D208 D207 D206 D204 D203 D202 D205 D201 2'-11" W206 W201 W207 W210 W211 W212 W212 W212 W213W214W213W215W216 W209 W208W208 W202W203 W204 3'-034"3'-034" 16C 23 28 30 2 34 31 25 26 3 30 3127 45 37 36 Slope 2% 35 1/2" Gyp. board under stairs and enclosedside of walls 22 39 34 28 46 2 26 3 1'- 6 " 23 21'- 6 " 34 28 31 30 33 33 W2 0 5 W216 5" 212" 33 44 22 22 Adhered Brick Veneer Unit "A" Unit "B" 8'-2"1'-7" W206 1'-2"1'-2"11" Roof Below 2'-0" 263 8 W D Gat e 50 50 Bathroom at Second level shall be provided with reinforcement for grab bars 3'- 1 " 2'- 0 " 2'- 1 " 1" 3'- 1 " 3'- 1 " 2" 11 " W2 0 5 3'- 1 " 3'- 1 " 3'-0 " Se t b a c k 3'- 0 " Se t b a c k 5'-0" Setback 3'-0 " Se t b a c k 3'- 0 " Se t b a c k 3'- 3 " 1W3 1W1 1W1 1W2 1W1 Dashed line Indicates 1 Hour FireResistance-Rated wall Dashed line Indicates 1 Hour Fire Rated wall 42 42 1W4 Property Line Property Line Pr o p e r t y L i n e Pro p e r t y L i n e Slope2% N52 46'30"E 25.00' N52 46'30"E 54.46' N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' N39 35'30"W 1.00'Property Line N52 46'30"E 79.33' N3 9 3 5 ' 3 0 " W 2 6 . 0 2 ' 6 W10x77 512"512" 512" W10x77 101316 " 1'-0 316" 101316 " 1'- 0 316 " Attic access from below of deck Second Level - Floor Plan SCALE: 1/4" = 1'-0" SECOND LEVEL FLOOR PLAN PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A2.3 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 596 Sq.Ft. 262 Sq.Ft.Third Level Living 1,448 Sq.Ft.Total Living Total Building Area (Buildable Area) 1,438.33 Sq.Ft. x 2 = 2,876.66 Sq.Ft.Maximum Floor Area : 290 Sq.Ft. 870 Sq.Ft. Unit A Unit B 444 Sq.Ft. 880 Sq.Ft.1,176 Sq.Ft. 262 Sq.Ft. 2,318 Sq.Ft. 2,762 Sq.Ft. Total max allowable 69 Sq.Ft.Second Level Deck 69 Sq.Ft. 388 Sq.Ft.Roof Level Deck 882 Sq.Ft. Total Roof Deck 1,085 Sq.Ft. Carport 275 Sq.Ft. 580 Sq.Ft. 99 Sq.Ft.Main Level Deck 35 Sq.Ft. 134 Sq.Ft. 529 Sq.Ft.556 Sq.Ft. 494 Sq.Ft. FLOOR PLAN KEY NOTES SYMBOLXX A Elevation Key D C B Interior 20. PROVIDE SMOOTH METAL DUCT FOR DRYER EXHAUSTEXTENDING TO OUTSIDE WITH BACKDRAFT DAMPER.PER CMC. 21. FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OTHERCOMPONENTS SHALL BE LISTED AND INSTALLED INACCORDANCE WITH THEIR LISTING AND MANUFACTURERINSTRUCTIONS. 22. DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THETERMINATION OF THE FACTORY-BUILT CHIMNEYS EXCEPTWHERE SUCH SHROUDS ARE LISTED AND LABELEDFOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEYSYSTEM AND ARE INSTALLED IN ACCORDANCE WITHMANUFACTURER'S INSTALLATION INSTRUCTION.CMC 802.5.2.4 GASEOUS FUEL BURNING PAN MUST BEPERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACEMUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDSMANDATORY MEASURES. 23. NET AREA OF SHOWER ENCLOSURES SHALL BE NOT LESSTHAN 1,024 Sq In (7.1 Sq. Ftt.) OF FLOOR AREA, AND A MINIMUMOF 30 INCH DIAMETER CIRCLE. PER CPC 408.6 24. HANDRAILS: a. HANDRAILS OTHER THAN CIRCULAR CROSS SECTIONS SHALL HAVE A PERIMETER DIMENSION OF 4 TO 6.25 INCHESWITH A MAXIMUM CROSS SECTION OF 2.25 INCHES. R311.7.8.3item 1 b. HANDRAILS WITH A PERIMETER GREATER THAN 6.25 INCHESSHALL COMPLY WITH R311.7.8.3 item 2. c. HANDRAILS SHALL BE CONTINUOUS WITHOUT INTERRUPTIONBY NEWEL POST OR OTHER OBSTRUCTION, EXCEPT AT THELANDING, VOLUTE OR TURNOUT ON LOWEST TREAD.R311.7.8.2 Exception 1&2. 1 LINE OF CABINET(S) ABOVE 2 CABINET(S) 3 BUILT-IN MILLWORK 4 KITCHEN ISLAND 5 PANTRY WITH SHELVES 6 24" FARM HOUSE SINK WITHGARBAGE DISPOSAL 7 30" FARM HOUSE SINK WITHGARBAGE DISPOSAL 8 24" GAS RANGE / OVENAS SELECTED BY OWNER 9 WOLF 36" GAS RANGE / OVENAS SELECTED BY OWNER 10 WOLF OVEN AS SELECTED BY OWNER 11 WOLF MICROWAVE OVEN ASSELECTED BY OWNER 12 VENT HOOD TO OUTSIDE AIR,MINIMUM EXHAUST RATE FOR THE KITCHEN RANGES SHALL FOLLOWTABLE 150.0-G. BEES 150(o) Exc. 5 TO150.2(a), & ASHRAE Std. 62,2.MINIMUM EXHAUST RATE FOR UNIT "A"IS 250 CFM AND FOR UNIT "B" IS 280 CFM.REFER TO TABLE 150.0-H ON SHEET A-6.1NOTE # 54 FOR MINIMUM DUCT SIZE.UNIT "A" WILL HAVE AN 8" DUCT,& UNIT "B" WILL HAVE AN 9" DUCT. 13A SUB-ZERO PRO REFRIGERATORSELECTED BY OWNER WALL LEGENDFLOOR PLAN NOTES 1. SMOKE DETECTORS SHALL BE INTERCONNECTED SUCHTHAT AT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALLALARMS. SMOKE DETECTORS SHALL BE "HARD WIRED" ANDSHALL BE EQUIPPED WITH A BATTERY BACK UP. CARBONMONOXIDE DETECTORS SHALL BE "HARD WIRED" ANDSHALL BE EQUIPPED WITH A BATTERY BACK UP.CRC R314 & CRC R315.3 2. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS ANDSIMILAR FIXTURES SHALL BE PROVIDED WITH ANEXHAUST FAN WITH A MINIMUM CAPACITY OF 50 cfmCBC 1203.4.2.1, CMC T4-4 3. SHOWERS AND TUB / SHOWERS SHALL BE PROVIDED WITHPRESSURE BALANCE OR THERMOSTATIC MIXING VALVECONTROLS. PER CPC. 4. WATER CLOSETS SHALL USE NO MORE THAN 1.28 GALLONSOF WATER PER FLUSH, LAVATORIES FAUCETSNO MORE THAN 1.5 GPM AT 60 PSI, KITCHENFAUCETS NO MORE THAN 1.8 GPM AT 60 PSI,SHOWER HEAD NO THAN 2 GPM, CGC SECTION 4.303 5. WHEN A SHOWER IS PROVIDED WITH MULTIPLE SHOWERHEADS, THE SUM OF FLOW TO ALL THE HEADS SHALL NOTEXCEED THE 20% REDUCED LIMIT, OR THE SHOWER SHALLBE DESIGNED SO THAT ONLY ONE HEAD IS ON AT A TIME.CGC 4.303.2 6. LANDSCAPE IRRIGATION WATER USE SHALL HAVEWEATHER BASED CONTROLLERS. CGC 4.304.1 7. PROVIDED WATER EFFICIENT LANDSCAPE IRRAGATIONDESIGN WHERE POTABLE WATER USE DOES NOT EXCEED65% OF THE ETo. (TIER 1) 8. A MINIMUM OF 50% OF CONSTRUCTION WASTE IS TO BERECYCLED. CGC 4.408.1 9. THE BUILDER IS TO PROVIDE AN OPERATION MANUAL(CONTAINING INFORMATION FOR MAINTAINING APPLIANCES,ETC.) FOR THE OWNER AT THE TIME OF FINAL INSPECTION.CGC 4.410.1 10. DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TOBE SEALED, AND MECHANICAL EQUIPMENT IS TO BECOVERED CGC 4.504.1 11. VOC'S MUST COMPLY WITH THE LIMITATIONS LISTED INSECTION 4.504.3 AND TABLES 4.504.1, 4.504.2, 4.504.3, AND4.504.5 FOR: ADHESIVES, PAINTS AND COATINGS, CARPETAND COMPOSITION WOOD PRODUCTS. CGC 4.504.2 12. THE MOISTURE CONTENT OF WOOD SHALL NOT EXCEED 19%BEFORE IT IS ENCLOSED IN CONSTRUCTION. THE MOISTURECONTENT NEEDS TO BE CERTIFIED BY ONE OF 3 METHODSSPECIFIED. BUILDING MATERIALS WITH VISIBLE SIGNS OFWATER DAMAGE SHOULD NOT BE USED IN CONSTRUCTION.THE MOISTURE CONTENT MUST BE DETERMINED BY THECONTRACTOR BY ONE OF THE METHODS LISTED IN CGCSECTION 4.505.3 13. BATHROOM FANS SHALL BE ENERGY STAR RATED, VENTEDDIRECTLY TO THE OUTSIDE AND CONTROLLED BY AHUMIDISTAT. CGC 4.506.1 14. IF PROVIDED, WHOLE HOUSE EXHAUST FANS SHALL HAVEINSULATED COVERS OR LOUVERS WHICH CLOSE THE FANIS OFF. THE COVERS OR LOUVERS SHALL HAVE MINIMUMR4.2 INSULATION. CGC 5.507.1 15. PROVIDE NON-REMOVABLE BACKFLOW PREVENTION DEVICES AT ALL EXTERIOR HOSE BIBS. PER CPC. 16. PROVIDE PRESSURE RELIEF VALVE WITH DRAIN TO OUTSIDEAT WATER HEATERS. PER CPC. 17. HEATING AND AC SHALL BE SIZED AND SELECTED BYACCA MANUAL J OR ASHRAE HANDBOOK OR EQUIVALENT.THE DUCT SHALL BE SIZED IN ACCORDANCE WIHT ONEOF THE ACCA METHODS LISTED IN CGC SECTION 4.507.2 18. PRIOR TO FINAL APPROVAL OF THE BUILDING LICENSEDCONTRACTOR, ARCHITECT OR ENGINEER IN RESPOSIBLECHARGE OF THE OVERALL CONSTRUCTION MUST COMPLETEAND SIGN THE GREEN BUILDING STANDARDS CERTIFICATIONFORM AND GIVEN TO THE BUILDING DEPARTMENT OFFICALTO BE FILED WITH THE APPROVED PLANS. 19. PROVIDE FIRE BLOCKS AND DRAFT STOPS IN THE WOODFRAME FLOOR CONSTRUCTION CONTAINING CONCEALEDSPACE WHERE THERE IS USABLE SPACE ABOVE AND BELOWTHE CONCEALED SPACE. SUCH DRAFT STOPS SHOULD BEINSTALLED SO THAT THE AREA OF THE CONCEALED SPACEDOES NOT EXCEED 1000 SQ. FT. DRAFTSTOPPING SHOULDDIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. PER CBC. 13B REFRIGERATOR SELECTED BY OWNER 14 DISHWASHER AS SELECTED BY OWNER 15 TRASH RECYCLING BIN 16A PREFABRICATED METAL FIREPLACE:BY:"ORTAL" MODEL ORTAL MINIMAL130 TRADITIONAL 42" GAS ONLYDIRECT VENT OR APPROVED EQUAL.INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODESANSI Z21.88/CSA 2.33 16B MASONRY FIREPLACE MANUFACTURESMASON-LITE MODEL MGFP-39 ORAPPROVED EQUAL. ICC REPORT ESR-2401TESTED AND LISTED BY PFS CORP., USAREPORT No. 08-154 16C PREFABRICATED METAL FIREPLACE:BY:EMPIRE COMFORT SYSTEMS,MODEL DVD42FP, GAS ONLY DIRECT-VENTOR APPROVED. INSTALL IN ACCORDANCEWITH THE MANUFACTURER'S PUBLISHEDINSTALLATION INSTRUCTIONS, ANDAPPLICABLE CODES. CERTIFIED INACCORDANCE WITH AMERICAN NATIONALSTANDARD/CSA STANDARDANSI Z221.88 / CSA 2.33 AND BYUNDERWRITERS LABORATORIES AS ADIRECT-VENT GAS FIREPLACE HEATER. 17 FIREPLACE HEARTH 18 EXTERIOR FINISH OPENING ONE HOUR CONSTRUCTION LOW WALL 2 X 6 STUD WALL 2 X 4 STUD WALL 2 X 8 STUD WALL 19 FLAT DRYWALL OPENING 20 FLAT CASED OPENING 21 DECORATIVE WOOD BEAMS 22 HANDRAIL 23 GUARDRAIL 24 LOW WALL 25 LOW LINEN 26 SHELF AND POLE 27 DOUBLE SHELF AND POLE 28 LAVATORY 29 PEDESTAL SINK 30 MUDSET CERAMIC TILE SEAT 31 HOT MOPPED SHOWER PAN WITH MUDSETCERAMIC TILED WAINSCOT TO 84" AFF W/PRESSURE BALANCE THERMOSTATICMIXING VALVE 32 BUILT-IN SOAP NICHE 33 TEMPERED GLASS SHOWER DOOR 34 WATER CLOSET TO BE 30" MIN WIDE WITH24" IN FRONT OF TOILET. LOW FLUSHTOILETS 1.28 GALLONS PER FLUSH 35 WASHER SPACE. PROVIDE RECESSED HOT ANDCOLD WATER BIBBS, PROVIDE FLOOR DRAIN. 36 DRYER SPACE. PROVIDE DRYER VENT TOOUTSIDE AIR PER CMC 37 STACKED WASHER & DRYER, PROVODECOLD WATER BIBBS, PROVIDE FLOOR DRAIN 38 INSTANTANEOUS TANKLESSWATER HEATER .94 EF / 199,000 Btu/hr 39 MECHANICAL EQUIPMENT 40 ATTIC ACCESS 41 LINE OF FLOOR ABOVE 42 DECK DRAIN & OVERFLOW 43 ROOF DRAIN 44 BUILT-UP ROOFING AT MECHANICAL WELL 45 MOUNTED AC UNITREFER TO MECHANICAL PLANS 46 ELEVATOR MODEL LLT-950 (TRACTION)HOR HP4 MG 12 RH RAIL, FRONT/REAROPENINGS BY RESIDENTIAL ELEVATOR INC.OR APPROVED EQUAL, ELEVATOR SHAFTBELOW DESIGN FLOOD ELEVATIONSHALL COMPLY WITH ASCE 24-14 SEC. 7.5ASME/ANSI A17.1 NATIONAL SAFETY CODESFOR ELEVATORS SECTION 5.3 47 CONCRETE GARAGE FLOOR 48 CONCRETE DRIVEWAY 49 BREAKAWAY WALL 50 DRYER EXHAUST VENT TO OUTSIDE AIR, DUCTSHALL TERMINATE NO LESS THAN 3'-0" FEETFROM OPENINGS INTO THE BUILDING.(502.2.1 CMC) REINFORCEMENT FOR GRAB BARS - R327.1.1 AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BEPROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCEWITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THEENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH THISSECTION. 1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHERCONSTRUCTION MATERIALS APPROVED BY THE ENFORCINGAGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCHNOMINAL LUMBER, [1 1/2" INCH BY 7 1/4" ACTUAL DIMENSION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUALHEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BELOCATED BETWEEN 32" INCHES AND 39 1/4" INCHES ABOVETHE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. 3. WATER CLOSET REINFORCEMENT SHALL BE INSTALL ONBOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALLAND THE BACK WALL. 4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHEREWALL FRAMING IS PROVIDED. 5. BATHTUB AND COMBINATION BATHTUB/SHOWERREINFORCEMENT SHALL BE CONTINUOUS ON EACH END OFTHE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACKWALL REINFORCEMENT FOR A LOW GRAB BAR SHALL BEPROVIDED WITH THE BOTTOM EDGE LOCATED NO MORETHAN 6" INCHES ABOVE THE BATHTUB RIM. EXCEPTIONS: 1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO ASIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THEBATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OFFLOOR MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRABBAR REINFORCEMENTS APPROVED BY THE ENFORCINGAGENCY. 2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALLFRAMING FOR PRE-FABRICATED SHOWER ENCLOSURESAND BATHTUB WALL PANELS WITH INTEGRAL FACTORY-INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLEDREINFORCEMENT FOR GRAB BARS IS PROVIDED. 3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATIONOF REINFORCEMENT AND/OR GRAB BARS SHALL BEPERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATIONOF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATEMETHOD IS APPROVED BY THE ENFORCING AGENCY. 4. BATHTUBS WITH NO SURROUNDING WALLS , OR WHEREWALL PANELS DO NOT PERMIT THE INSTALLATION OFREINFORCEMENT SHALL BE PERMITTED, PROVIDEDREINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTEDGRAB BARS ADJACENT TO THE BATHTUB ON AN ALTERNATEMETHOD IS APPROVED BY THE ENFORCING AGENCY. 5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FORBATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETESLAB FLOORS. DOCUMENTATION FOR GRAB BAR REINFORCEMENT - R327.1.1.1 INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCAIONOF THE GRAB BAR REINFORCEMENT SHALL BE PLACED IN THEOPERATION AND MAINTENANCE MANUAL IN ACCORDANCE WITHTHE CALIFORNIA GREEN BUILDING STANDARDS CODE.SECTION 4.410.1. SOUND TRANSMISSION CONTROL NOTES 1. SOUND INSULATION NOTES:a. APPROVED ACOUSTICAL SEALANT SHALL BEPROVIDED ALONG THE JOINT BETWEEN THE FLOORAND THE SEPARATION WALL.b. ALL PENETRATIONS INTO SOUND-RATED PARTITIONSOF FLOOR-CEILING ASSEMBLIES SHALL BE SEALEDWITH AN APPROVED PERMANENT RESILIENTSEALANT.c. ALL RIGID CONDUIT, DUCTS, PLUMBING PIPES,AND APPLIANCE VENTS LOCATED IN SOUNDASSEMBLIES SHALL BE ISOLATED FROM THEBUILDING CONSTRUCTION BY MEANS OF RESILIENTSLEEVES, MOUNTS, OR MINIMUM 1/4" THICKAPPROVED RESILIENT MATERIAL.EXCEPTION: GAS PIPING NEED NOT BE ISOLATED.d. METAL VENTILATING AND CONDITIONED AIR DUCTSLOCATED IN SOUND ASSEMBLIES SHALL BE LINED.e. MINERAL FIBER INSULATION SHALL BE INSTALLEDIN JOIST SPACES TO A POINT 12" BEYOND THE PIPEOR DUCT, WHENEVER A PLUMBING PIPE OR DUCTPENETRATES A FLOOR-CEILING ASSEMBLY OR WHERESUCH UNIT PASSES THROUGH THE PLANE OF THEFLOOR-CEILING WITHIN A WALL. 2. A SOUND TRANSMISSION CLASS (STC) RATING OF NOT LESSTHAN 50 BASED ON LAVATORY TESTING (45 IF FIELD TESTED)IS REQUIRE (NBMC 15.05.203, CBC 1206.2) 3. A SOUND TRANSMISSION CLASS (STC) RATING ANDIMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN50 BASED ON LABORATORY TESTING (45 IF FIELD TESTED)IS REQUIRED. (NBMC 15.05.230, CBC 1206.2, 1206.30) LINE INDICATESMINIMUM 0.5-HOURFIRE-RESISTANCE-RATED SINGLE WALL LINE INDICATES THE MINIMUM 1-HOURFIRE-RATED WALL 1W1 LINE INDICATESMINIMUM 0.5-HOURFIRE-RESISTANCE-RATED DOUBLE WALL 1W2 1W3 LINE INDICATES OCCUPANCYSEPARATION WALL 1W5 LINE INDICATES THEMINIMUM 1-HOUR FIRE-RATED LOW WALL 1W4 REFER TO T-24 SHEETS FOR CF1R FORMS AND COMPLIANCE INFORMATION INSULATION SCHEDULE BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.32 U-factor, 0.23 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.23 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-30 (2x4) plus R-15 (2x4) below roof deckRoof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 10.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storag: 5kWh; 95% charging/discharging BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-38 (2x4)Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 9.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storage: 5kWh; 95% charging/discharging Unit "A"Unit "B" NOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL 58 LOT 5 LOT 3 Alley Se a s h o r e D r i v e 5'-4" F.F. El. 36.46 A / C Dn 15R 46 3'-2" 4'-212" 17'-11"57'-9" 75'-8" 8'-5" 16'-512" 75'-8" 57'-9" 1'-3" 6'-112" 17'-11" 2'- 0 " 14 ' - 1 0 " 18 ' - 1 0 " 8'-012" 2'-0 " 3'-10" 18 ' - 1 0 " 3'- 1 " 3'- 1 " Office Ba 3 Roof Deck A 7'-2" 8" 6'-4" 7'-2" 7'- 2 "15'-0" T.O. RailEl 41.25' A/C Well B Roof Dn 14R Deck Setback Minimum 15'-0" to Roof Deck High Point B A4.1 G A4.3 E A4.2 A A4.1 1 2 735 D A4.2 FA4.3 C A4.1 4 28.90 FSLanding below 3'-11" 1'- 2 12" 7'- 2 " 3'-3 12" 6'-6"4'-6"6'-11" 11 " 1'- 1 0 12" 212"3'-2"4'-5"8'-3" 10" 5'- 9 " 712" 3'- 6 " 5'- 8 " 512"4'-7"312" 312" 1'- 5 12" 4'- 3 12" 1'-3"1'-3" 2'-1112" 3'-034"3'-034" 5'-1134"3'-412" 1'- 1 0 " 2'- 5 12" 3'- 4 12" 3'-3 12" 3'-3 12" W304 W303 W302 W301 D302 D301 D304 5'- 1 1 12" 4'-1 1 " 3'-4 " 8" 45 23 16B Fully adhered waterproofDeck membrane ICCESR-2701 "Life Deck AL" over sloped EPS deck System ICC ESR-1962 Treads at 10.5" Each 6'-6"4'-6"6'-11" 48'-9" 14'-5"8'-612" Slo p e 2% Slo p e 2%23 42 23 Treads at10.25" Each Fully adhered waterproofDeck membrane ICC ESR-2701 "Life Deck AL"over sloped EPS deck System ICC ESR-1962 9'-0" 512" 10'-6" 23 22 Roof Below Roof Below Roof Below 2'-0"6'-0"26'-6" 22 30 31 33 D303 34 29 40 A / C 45 5" 5'-0 " 44 44 Adhered BrickVeneer Unit "A" Spa by others 6'-0" Built-in Counter 3'-3" CoveredDeck Roof Below 3'- 4 " 2'-712" 4'-712" 12 ' - 1 0 12" 1'- 1 0 " 1'-1 1 12" 3'-912" 2'-0"3'-0" 1'-0 " 2" 2'-0 " 5'-0" Setback 3'- 0 " Se t b a c k 2'- 7 " 3'- 0 " Se t b a c k 3'- 0 " Se t b a c k 6" 2'-7 " 4'-3 " 6" 3'-7 " 8" 3'-0 " Se t b a c k 3'- 3 " 2" 3'- 1 " 2'- 1 " "A" T r a v e l D i s t a n c e 24'-4 " "B" Travel Distance15'-1" "C " T r a v e l D i s t a n c e 8'-7 " "D" Travel Distance1'-9 3/4" 2638 WD Gate Total TravelDistance 49'-9 3/4" 26 3 8 W D Gat e Dashed line Indicates1 Hour FireResistance-Rated wall 1W1 1W1 1W1 Dashed line Indicates 1 Hour Fire Rated wall 1W3 1W3 3'-114" 4242 42 Deck High Point Slo p e 2% Slo p e 2% 42 42 Slo p e 2% Property Line Property Line Pr o p e r t y L i n e Slop e 2% 3'- 3 " Property Line N39 35'30"W 1.00'Property Line N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' N3 9 3 5 ' 3 0 " W 2 6 . 0 2 ' Pro p e r t y L i n e N52 46'30"E 54.46' N52 46'30"E 25.00' 3'-0" 7'- 0 " 7'-0"3'-1 1 " Deck HighPoint 3'- 1 1 " Slo p e 2% 6 Spa under separatereview and permit 3:1 2 Unit B Slo p e 2% 42 Un i t A 42 Third Level - Floor Plan SCALE: 1/4" = 1'-0" THIRD LEVEL FLOOR PLAN PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A2.4 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 596 Sq.Ft. 262 Sq.Ft.Third Level Living 1,448 Sq.Ft.Total Living Total Building Area (Buildable Area) 1,438.33 Sq.Ft. x 2 = 2,876.66 Sq.Ft.Maximum Floor Area : 290 Sq.Ft. 870 Sq.Ft. Unit A Unit B 444 Sq.Ft. 880 Sq.Ft. 1,176 Sq.Ft. 262 Sq.Ft. 2,318 Sq.Ft. 2,762 Sq.Ft. Total max allowable 69 Sq.Ft.Second Level Deck 69 Sq.Ft. 388 Sq.Ft.Roof Level Deck 882 Sq.Ft. Total Roof Deck 1,085 Sq.Ft. Carport 275 Sq.Ft. 580 Sq.Ft. 99 Sq.Ft.Main Level Deck 35 Sq.Ft. 134 Sq.Ft. 529 Sq.Ft.556 Sq.Ft. 494 Sq.Ft. FLOOR PLAN KEY NOTES SYMBOLXX A Elevation Key D C B Interior 20. PROVIDE SMOOTH METAL DUCT FOR DRYER EXHAUSTEXTENDING TO OUTSIDE WITH BACKDRAFT DAMPER.PER CMC. 21. FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OTHERCOMPONENTS SHALL BE LISTED AND INSTALLED INACCORDANCE WITH THEIR LISTING AND MANUFACTURERINSTRUCTIONS. 22. DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THETERMINATION OF THE FACTORY-BUILT CHIMNEYS EXCEPTWHERE SUCH SHROUDS ARE LISTED AND LABELEDFOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEYSYSTEM AND ARE INSTALLED IN ACCORDANCE WITHMANUFACTURER'S INSTALLATION INSTRUCTION.CMC 802.5.2.4 GASEOUS FUEL BURNING PAN MUST BEPERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACEMUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDSMANDATORY MEASURES. 23. NET AREA OF SHOWER ENCLOSURES SHALL BE NOT LESSTHAN 1,024 Sq In (7.1 Sq. Ftt.) OF FLOOR AREA, AND A MINIMUMOF 30 INCH DIAMETER CIRCLE. PER CPC 408.6 24. HANDRAILS: a. HANDRAILS OTHER THAN CIRCULAR CROSS SECTIONS SHALL HAVE A PERIMETER DIMENSION OF 4 TO 6.25 INCHESWITH A MAXIMUM CROSS SECTION OF 2.25 INCHES. R311.7.8.3item 1 b. HANDRAILS WITH A PERIMETER GREATER THAN 6.25 INCHESSHALL COMPLY WITH R311.7.8.3 item 2. c. HANDRAILS SHALL BE CONTINUOUS WITHOUT INTERRUPTIONBY NEWEL POST OR OTHER OBSTRUCTION, EXCEPT AT THELANDING, VOLUTE OR TURNOUT ON LOWEST TREAD.R311.7.8.2 Exception 1&2. 1 LINE OF CABINET(S) ABOVE 2 CABINET(S) 3 BUILT-IN MILLWORK 4 KITCHEN ISLAND 5 PANTRY WITH SHELVES 6 24" FARM HOUSE SINK WITHGARBAGE DISPOSAL 7 30" FARM HOUSE SINK WITHGARBAGE DISPOSAL 8 24" GAS RANGE / OVENAS SELECTED BY OWNER 9 WOLF 36" GAS RANGE / OVENAS SELECTED BY OWNER 10 WOLF OVEN AS SELECTED BY OWNER 11 WOLF MICROWAVE OVEN ASSELECTED BY OWNER 12 VENT HOOD TO OUTSIDE AIR,MINIMUM EXHAUST RATE FOR THE KITCHEN RANGES SHALL FOLLOWTABLE 150.0-G. BEES 150(o) Exc. 5 TO150.2(a), & ASHRAE Std. 62,2.MINIMUM EXHAUST RATE FOR UNIT "A"IS 250 CFM AND FOR UNIT "B" IS 280 CFM.REFER TO TABLE 150.0-H ON SHEET A-6.1NOTE # 54 FOR MINIMUM DUCT SIZE.UNIT "A" WILL HAVE AN 8" DUCT,& UNIT "B" WILL HAVE AN 9" DUCT. 13A SUB-ZERO PRO REFRIGERATORSELECTED BY OWNER WALL LEGENDFLOOR PLAN NOTES 1. SMOKE DETECTORS SHALL BE INTERCONNECTED SUCHTHAT AT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALLALARMS. SMOKE DETECTORS SHALL BE "HARD WIRED" ANDSHALL BE EQUIPPED WITH A BATTERY BACK UP. CARBONMONOXIDE DETECTORS SHALL BE "HARD WIRED" ANDSHALL BE EQUIPPED WITH A BATTERY BACK UP.CRC R314 & CRC R315.3 2. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS ANDSIMILAR FIXTURES SHALL BE PROVIDED WITH ANEXHAUST FAN WITH A MINIMUM CAPACITY OF 50 cfmCBC 1203.4.2.1, CMC T4-4 3. SHOWERS AND TUB / SHOWERS SHALL BE PROVIDED WITHPRESSURE BALANCE OR THERMOSTATIC MIXING VALVECONTROLS. PER CPC. 4. WATER CLOSETS SHALL USE NO MORE THAN 1.28 GALLONSOF WATER PER FLUSH, LAVATORIES FAUCETSNO MORE THAN 1.5 GPM AT 60 PSI, KITCHENFAUCETS NO MORE THAN 1.8 GPM AT 60 PSI,SHOWER HEAD NO THAN 2 GPM, CGC SECTION 4.303 5. WHEN A SHOWER IS PROVIDED WITH MULTIPLE SHOWERHEADS, THE SUM OF FLOW TO ALL THE HEADS SHALL NOTEXCEED THE 20% REDUCED LIMIT, OR THE SHOWER SHALLBE DESIGNED SO THAT ONLY ONE HEAD IS ON AT A TIME.CGC 4.303.2 6. LANDSCAPE IRRIGATION WATER USE SHALL HAVEWEATHER BASED CONTROLLERS. CGC 4.304.1 7. PROVIDED WATER EFFICIENT LANDSCAPE IRRAGATIONDESIGN WHERE POTABLE WATER USE DOES NOT EXCEED65% OF THE ETo. (TIER 1) 8. A MINIMUM OF 50% OF CONSTRUCTION WASTE IS TO BERECYCLED. CGC 4.408.1 9. THE BUILDER IS TO PROVIDE AN OPERATION MANUAL(CONTAINING INFORMATION FOR MAINTAINING APPLIANCES,ETC.) FOR THE OWNER AT THE TIME OF FINAL INSPECTION.CGC 4.410.1 10. DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TOBE SEALED, AND MECHANICAL EQUIPMENT IS TO BECOVERED CGC 4.504.1 11. VOC'S MUST COMPLY WITH THE LIMITATIONS LISTED INSECTION 4.504.3 AND TABLES 4.504.1, 4.504.2, 4.504.3, AND4.504.5 FOR: ADHESIVES, PAINTS AND COATINGS, CARPETAND COMPOSITION WOOD PRODUCTS. CGC 4.504.2 12. THE MOISTURE CONTENT OF WOOD SHALL NOT EXCEED 19%BEFORE IT IS ENCLOSED IN CONSTRUCTION. THE MOISTURECONTENT NEEDS TO BE CERTIFIED BY ONE OF 3 METHODSSPECIFIED. BUILDING MATERIALS WITH VISIBLE SIGNS OFWATER DAMAGE SHOULD NOT BE USED IN CONSTRUCTION.THE MOISTURE CONTENT MUST BE DETERMINED BY THECONTRACTOR BY ONE OF THE METHODS LISTED IN CGCSECTION 4.505.3 13. BATHROOM FANS SHALL BE ENERGY STAR RATED, VENTEDDIRECTLY TO THE OUTSIDE AND CONTROLLED BY AHUMIDISTAT. CGC 4.506.1 14. IF PROVIDED, WHOLE HOUSE EXHAUST FANS SHALL HAVEINSULATED COVERS OR LOUVERS WHICH CLOSE THE FANIS OFF. THE COVERS OR LOUVERS SHALL HAVE MINIMUMR4.2 INSULATION. CGC 5.507.1 15. PROVIDE NON-REMOVABLE BACKFLOW PREVENTION DEVICES AT ALL EXTERIOR HOSE BIBS. PER CPC. 16. PROVIDE PRESSURE RELIEF VALVE WITH DRAIN TO OUTSIDEAT WATER HEATERS. PER CPC. 17. HEATING AND AC SHALL BE SIZED AND SELECTED BYACCA MANUAL J OR ASHRAE HANDBOOK OR EQUIVALENT.THE DUCT SHALL BE SIZED IN ACCORDANCE WIHT ONEOF THE ACCA METHODS LISTED IN CGC SECTION 4.507.2 18. PRIOR TO FINAL APPROVAL OF THE BUILDING LICENSEDCONTRACTOR, ARCHITECT OR ENGINEER IN RESPOSIBLECHARGE OF THE OVERALL CONSTRUCTION MUST COMPLETEAND SIGN THE GREEN BUILDING STANDARDS CERTIFICATIONFORM AND GIVEN TO THE BUILDING DEPARTMENT OFFICALTO BE FILED WITH THE APPROVED PLANS. 19. PROVIDE FIRE BLOCKS AND DRAFT STOPS IN THE WOODFRAME FLOOR CONSTRUCTION CONTAINING CONCEALEDSPACE WHERE THERE IS USABLE SPACE ABOVE AND BELOWTHE CONCEALED SPACE. SUCH DRAFT STOPS SHOULD BEINSTALLED SO THAT THE AREA OF THE CONCEALED SPACEDOES NOT EXCEED 1000 SQ. FT. DRAFTSTOPPING SHOULDDIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. PER CBC. 13B REFRIGERATOR SELECTED BY OWNER 14 DISHWASHER AS SELECTED BY OWNER 15 TRASH RECYCLING BIN 16A PREFABRICATED METAL FIREPLACE:BY:"ORTAL" MODEL ORTAL MINIMAL130 TRADITIONAL 42" GAS ONLYDIRECT VENT OR APPROVED EQUAL.INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODESANSI Z21.88/CSA 2.33 16B MASONRY FIREPLACE MANUFACTURESMASON-LITE MODEL MGFP-39 ORAPPROVED EQUAL. ICC REPORT ESR-2401TESTED AND LISTED BY PFS CORP., USAREPORT No. 08-154 16C PREFABRICATED METAL FIREPLACE:BY:EMPIRE COMFORT SYSTEMS,MODEL DVD42FP, GAS ONLY DIRECT-VENTOR APPROVED. INSTALL IN ACCORDANCEWITH THE MANUFACTURER'S PUBLISHEDINSTALLATION INSTRUCTIONS, ANDAPPLICABLE CODES. CERTIFIED INACCORDANCE WITH AMERICAN NATIONALSTANDARD/CSA STANDARDANSI Z221.88 / CSA 2.33 AND BYUNDERWRITERS LABORATORIES AS ADIRECT-VENT GAS FIREPLACE HEATER. 17 FIREPLACE HEARTH 18 EXTERIOR FINISH OPENING ONE HOUR CONSTRUCTION LOW WALL 2 X 6 STUD WALL 2 X 4 STUD WALL 2 X 8 STUD WALL 19 FLAT DRYWALL OPENING 20 FLAT CASED OPENING 21 DECORATIVE WOOD BEAMS 22 HANDRAIL 23 GUARDRAIL 24 LOW WALL 25 LOW LINEN 26 SHELF AND POLE 27 DOUBLE SHELF AND POLE 28 LAVATORY 29 PEDESTAL SINK 30 MUDSET CERAMIC TILE SEAT 31 HOT MOPPED SHOWER PAN WITH MUDSETCERAMIC TILED WAINSCOT TO 84" AFF W/PRESSURE BALANCE THERMOSTATICMIXING VALVE 32 BUILT-IN SOAP NICHE 33 TEMPERED GLASS SHOWER DOOR 34 WATER CLOSET TO BE 30" MIN WIDE WITH24" IN FRONT OF TOILET. LOW FLUSHTOILETS 1.28 GALLONS PER FLUSH 35 WASHER SPACE. PROVIDE RECESSED HOT ANDCOLD WATER BIBBS, PROVIDE FLOOR DRAIN. 36 DRYER SPACE. PROVIDE DRYER VENT TOOUTSIDE AIR PER CMC 37 STACKED WASHER & DRYER, PROVODECOLD WATER BIBBS, PROVIDE FLOOR DRAIN 38 INSTANTANEOUS TANKLESSWATER HEATER .94 EF / 199,000 Btu/hr 39 MECHANICAL EQUIPMENT 40 ATTIC ACCESS 41 LINE OF FLOOR ABOVE 42 DECK DRAIN & OVERFLOW 43 ROOF DRAIN 44 BUILT-UP ROOFING AT MECHANICAL WELL 45 MOUNTED AC UNITREFER TO MECHANICAL PLANS 46 ELEVATOR MODEL LLT-950 (TRACTION)HOR HP4 MG 12 RH RAIL, FRONT/REAROPENINGS BY RESIDENTIAL ELEVATOR INC.OR APPROVED EQUAL, ELEVATOR SHAFTBELOW DESIGN FLOOD ELEVATIONSHALL COMPLY WITH ASCE 24-14 SEC. 7.5ASME/ANSI A17.1 NATIONAL SAFETY CODESFOR ELEVATORS SECTION 5.3 47 CONCRETE GARAGE FLOOR 48 CONCRETE DRIVEWAY 49 BREAKAWAY WALL 50 DRYER EXHAUST VENT TO OUTSIDE AIR, DUCTSHALL TERMINATE NO LESS THAN 3'-0" FEETFROM OPENINGS INTO THE BUILDING.(502.2.1 CMC) REINFORCEMENT FOR GRAB BARS - R327.1.1 AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BEPROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCEWITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THEENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH THISSECTION. 1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHERCONSTRUCTION MATERIALS APPROVED BY THE ENFORCINGAGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCHNOMINAL LUMBER, [1 1/2" INCH BY 7 1/4" ACTUAL DIMENSION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUALHEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BELOCATED BETWEEN 32" INCHES AND 39 1/4" INCHES ABOVETHE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. 3. WATER CLOSET REINFORCEMENT SHALL BE INSTALL ONBOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALLAND THE BACK WALL. 4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHEREWALL FRAMING IS PROVIDED. 5. BATHTUB AND COMBINATION BATHTUB/SHOWERREINFORCEMENT SHALL BE CONTINUOUS ON EACH END OFTHE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACKWALL REINFORCEMENT FOR A LOW GRAB BAR SHALL BEPROVIDED WITH THE BOTTOM EDGE LOCATED NO MORETHAN 6" INCHES ABOVE THE BATHTUB RIM. EXCEPTIONS: 1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO ASIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THEBATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OFFLOOR MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRABBAR REINFORCEMENTS APPROVED BY THE ENFORCINGAGENCY. 2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALLFRAMING FOR PRE-FABRICATED SHOWER ENCLOSURESAND BATHTUB WALL PANELS WITH INTEGRAL FACTORY-INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLEDREINFORCEMENT FOR GRAB BARS IS PROVIDED. 3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATIONOF REINFORCEMENT AND/OR GRAB BARS SHALL BEPERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATIONOF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATEMETHOD IS APPROVED BY THE ENFORCING AGENCY. 4. BATHTUBS WITH NO SURROUNDING WALLS , OR WHEREWALL PANELS DO NOT PERMIT THE INSTALLATION OFREINFORCEMENT SHALL BE PERMITTED, PROVIDEDREINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTEDGRAB BARS ADJACENT TO THE BATHTUB ON AN ALTERNATEMETHOD IS APPROVED BY THE ENFORCING AGENCY. 5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FORBATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETESLAB FLOORS. DOCUMENTATION FOR GRAB BAR REINFORCEMENT - R327.1.1.1 INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCAIONOF THE GRAB BAR REINFORCEMENT SHALL BE PLACED IN THEOPERATION AND MAINTENANCE MANUAL IN ACCORDANCE WITHTHE CALIFORNIA GREEN BUILDING STANDARDS CODE.SECTION 4.410.1. SOUND TRANSMISSION CONTROL NOTES 1. SOUND INSULATION NOTES:a. APPROVED ACOUSTICAL SEALANT SHALL BEPROVIDED ALONG THE JOINT BETWEEN THE FLOORAND THE SEPARATION WALL.b. ALL PENETRATIONS INTO SOUND-RATED PARTITIONSOF FLOOR-CEILING ASSEMBLIES SHALL BE SEALEDWITH AN APPROVED PERMANENT RESILIENTSEALANT.c. ALL RIGID CONDUIT, DUCTS, PLUMBING PIPES,AND APPLIANCE VENTS LOCATED IN SOUNDASSEMBLIES SHALL BE ISOLATED FROM THEBUILDING CONSTRUCTION BY MEANS OF RESILIENTSLEEVES, MOUNTS, OR MINIMUM 1/4" THICKAPPROVED RESILIENT MATERIAL.EXCEPTION: GAS PIPING NEED NOT BE ISOLATED.d. METAL VENTILATING AND CONDITIONED AIR DUCTSLOCATED IN SOUND ASSEMBLIES SHALL BE LINED.e. MINERAL FIBER INSULATION SHALL BE INSTALLEDIN JOIST SPACES TO A POINT 12" BEYOND THE PIPEOR DUCT, WHENEVER A PLUMBING PIPE OR DUCTPENETRATES A FLOOR-CEILING ASSEMBLY OR WHERESUCH UNIT PASSES THROUGH THE PLANE OF THEFLOOR-CEILING WITHIN A WALL. 2. A SOUND TRANSMISSION CLASS (STC) RATING OF NOT LESSTHAN 50 BASED ON LAVATORY TESTING (45 IF FIELD TESTED)IS REQUIRE (NBMC 15.05.203, CBC 1206.2) 3. A SOUND TRANSMISSION CLASS (STC) RATING ANDIMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN50 BASED ON LABORATORY TESTING (45 IF FIELD TESTED)IS REQUIRED. (NBMC 15.05.230, CBC 1206.2, 1206.30) LINE INDICATESMINIMUM 0.5-HOURFIRE-RESISTANCE-RATED SINGLE WALL LINE INDICATES THE MINIMUM 1-HOURFIRE-RATED WALL 1W1 LINE INDICATESMINIMUM 0.5-HOURFIRE-RESISTANCE-RATED DOUBLE WALL 1W2 1W3 LINE INDICATES OCCUPANCYSEPARATION WALL 1W5 LINE INDICATES THEMINIMUM 1-HOUR FIRE-RATED LOW WALL 1W4 REFER TO T-24 SHEETS FOR CF1R FORMS AND COMPLIANCE INFORMATION INSULATION SCHEDULE BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.32 U-factor, 0.23 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.23 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-30 (2x4) plus R-15 (2x4) below roof deckRoof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 10.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storag: 5kWh; 95% charging/discharging BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-38 (2x4)Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 9.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storage: 5kWh; 95% charging/discharging Unit "A"Unit "B" NOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL 59 RIDGE VALLEY T.O. Rail El 41.25' Top of RidgeEl 46.25' A/C Well BRID G E Roof V V Dn 14 R LOT 5 LOT 3 Alley Se a s h o r e D r i v e VA L L E Y Deck RID G E 3:12 3:12 3:1 2 3:1 2 3:12 3:12 3:12 3:1 2 3:1 2 3:1 2 15'-0" Minimum Setback to Roof5'-0" Setback SetbackMinimum 15'-0" to Roof BA4.1 GA4.3 EA4.2 AA4.1 1 2 735 DA4.2 F A4.3 CA4.1 4 RID G E 8" 8" 8" 8" 8" 8" 8"8"6" 4" DS ATTIC AREA #1 DS DS DS DS DS 11 " 1'- 1 0 12" 4'-6"6'-6" 10 1212 10 12 Deck High Point 12 11 1 2 9 8 4 5 10 4 5 9 8 1 Stair Landingbelow 11 9 8 5 4 13 A/C Well 2 2 2"2" 14 14 2" 2" 3 3 3:12 1 1 Spa atRoof Deck 2'- 0 " 3'-0 " Se t b a c k 3'-0 " Se t b a c k 3'- 3 " 3'-1 " 2'- 7 " 2'-5 " 3'- 0 " Set b a c k 6" 2'- 7 " 2" 3'-5 "3'- 0 " Set b a c k 3'- 7 " 8" 1'-1 12" 6" 8" 8" Slo p e Slo p e Slo p e Slop e Deck High Point Slo p e Slo p e 10 N52 46'30"E 54.46'Property Line N52 46'30"E 25.00'N39 35'30"W 1.00'Property Line N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' Pro p e r t y L i n e N52 46'30"E 79.33'Property Line 2'- 7 " N3 9 3 5 ' 3 0 " W 2 6 . 0 2 ' Pr o p e r t y L i n e ATTIC AREA #2 4" Slop e Deck HighPoint 6 Spa under separatereview and permit 13:12 Roof Plan SCALE: 1/4" = 1'-0" ROOF PLAN PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A3.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions ROOF LEGENDROOF KEY NOTES 1 STANDING SEAM METAL ROOFINGCOLOR: WEATHERED ZINC FINISH (SRI = 22)(CLASS "A") BY PETERSEN STANDING SEAMMETAL ROOFING, ICC REPORT No. ESR-4173OR APPROVED EQUAL. INSTALL PERMANUFACTURER'S SPECIFICATIONS ANDPRINTED INSTALLATION INSTRUCTIONS 2 BUILT-UP (CLASS "A")MODIFIED BITUMEN ROOFING OVEREXTERIOR GRADE ROOF SHEATHING1/4" : 12" MINIMUM SLOPE U.N.O. 3 STONE PAVING OVERDEX-O-TEX WEATHERWEAR ROOF AND DECK COVERINGICC ESR REPORT 1757INSTALL PER MANUFACTURER SPECIFICATIONS 4 LINE OF BUILDING BELOW 5 LINE OF ROOF BELOW 6 26 GA GALV METAL SADDLE AT CHIMNEY 7 CHIMNEY CAP SYMBOLXX DS INDICATES ROOF PITCH AND DIRECTION OF ROOF SLOPE INDICATES LOCATION OF METAL DOWNSPOUT. ROOF PLAN NOTES x : 121. CONTRACTOR SHALL VERIFY AREA OF ALLATTIC VENTS WITH MANUFACTURER. 2. ALL ROOF SHEATHING EDGES SHALL BEBLOCKED AND NAILED PER STRUCTURAL PLANS. IN ADDITION, CONTRACTOR SHALLALSO PROVIDE MIN. BLOCKING AND NAILINGAS REQUIRED BY THE ROOFING MFR. 3. PROVIDE CLASS A ROOF WITH FIRE STOP TOPREVENT INTRUSION OF FLAMES ANDEMBERS OR 1 LAYER OF No. 72 ASTM CAP SHEET 4. PROVIDE NOT LESS THAN 26 GA. GALV. FLASHINGOVER No. 72 ASTM CAP SHEET. 5. ROOF GUTTERS SHALL BE PROVIDED WITH THEMEANS TO PREVENT ACCUMULATION OFLEAVES AND DEBRIS. CBC 705A.4 6. ATTIC VENTS SHALL MEET THE FOLLOWINGREQUIREMENTS, CBC 1203. 7. OPENINGS SHALL HAVE CORROSION RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH 18" MINIMUM AND 14" MAXIMUM OPENING. 8. 50% OF THE REQUIRED VENTILATION AREA MUST BELOCATED AT LEAST 3 FOOT ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE PROVIDED BY EAVE OR CORNICE VENTS. 8 COPPER METAL GUTTER TYPICAL 9 COPPER METAL DOWNSPOUT TYPICAL 10 DECK DRAIN PER DETAIL - BY:THUNDERBIRD PRODUCTS, INCICC - ES REPORT PMG-1212CONNECTED TO DRAINAGE SYSTEM 11 CLOAKED VENT TILESSHEET METAL VENTS 12 GUARDRAIL 13 BUILT-UP CRICKET 2% MIN 14 ROOF MOUNTED COMPACT AC UNITREFER TO MECHANICAL PLANS & SPECIFICATIONS INDICATES OCLOAKED VENT SHEET METAL OR APPROVED EQUAL.NET FREE AREA 72 SQ. IN. HATCHING INDICATES ATTIC ZONES WITH ATTIC VENTILATION HATCHING INDICATESROOF DECK AREAS TOTAL = 144 SQ. IN. SQ. IN.144SQ. IN. EA. =72DORMER VENT - LOW PROFILE SQ. FT. / =150X 144 = VENTILATION REQUIRED: ATTIC AREA = VENTILATION PROVIDED: (2) 119 ATTIC AREA: 1 0.79114 SQ. FT.SQ. IN. TOTAL = 360 SQ. IN. SQ. IN.360SQ. IN. EA. =72DORMER VENT - LOW PROFILE SQ. FT. / =150 X 144 = VENTILATION REQUIRED:ATTIC AREA = VENTILATION PROVIDED: (5) 318 ATTIC AREA: 2 2.11 305 SQ. FT. SQ. IN. SHEET METALOR APPROVED EQUAL SHEET METAL OR APPROVED EQUAL 60 6'- 1 0 12" 10 34" T.Pl.EL. 28.01 1'-1 " T.Pl.EL. 18.93 Master Suite T.O.Shtg.EL. 37.54 8'- 0 " 7'-7 18" T.O.Shtg.EL. 20.01 T.O.Shtg. EL. 28.90 T.O.Railing EL. 41.25 3'- 8 " HP of Garage EL. 12.07 1'- 0 58" 7'- 0 34" Kitchen hB.O.Hdr. EL. 27.07 T.Pl.EL. 36.49 7'-0 34" SetbackSetback T.O.Slab EL. 17.25 24 ' - 0 " 3'-0"3'-0" 3 12 3 2 2 7B 4 16 4 16 6'-5 78" 6'-7 58" 7'- 1 58" T.O.BM EL. 44.17 T.O.BMEL. 44.02 Flat RoofMaximum Height 24'-0" EL.41.25 29 ' - 0 " Sloped Roof RidgeMaximum Height 29'-0"EL.46.25 Pro p e r t y L i n e 2'-51516" R-15 16 R-30 16 R-21 R-30 USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYS AND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVE SEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCHMINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOISTCAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREADINDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. B.O.Slab EL. 16.00 ofUnit A 8'- 0 " T.O.Shtg. EL. 28.90 T.O.Shtg.EL. 20.01 10 34" 7'- 7 18" 1'-0 58" 1'- 1 " 7'-0 34" T.Pl.EL. 18.93 T.Pl. EL. 28.01 T.O.RailingEL. 41.25 H.P. of GarageEL. 12.07 6'-1 0 12" 3'- 8 " T.O.Shtg.EL. 37.54 Living Room Carport T.O.SlabEL. 17.25 24 ' - 0 " 3'-0"3'-0" SetbackSetback 3 12 7'- 7 18" 3 16 2 16 4 4 7A 6'- 5 78" 6'-7 58" T.Pl.EL. 36.49 T.O.BMEL. 44.02T.O.BMEL. 44.17 29' - 0 " Pro p e r t y L i n e Sloped Roof RidgeMaximum Height 29'-0"EL.46.25 Flat RoofMaximum Height 24'-0"EL.41.25 Pro p e r t y L i n e R-30 R-21 R-3016 16 R-21 USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYSAND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVESEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCHMINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOISTCAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREADINDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. 8'- 1 " 7'- 7 12" T.Pl.EL. 26.16 T.Pl.EL. 35.32 B.O.SlabEL. 16.00 T.Pl.EL. 44.02 T.O.Slab EL. 17.25 T.O. SheathingEL.36.40 B.O.Hdr.EL. 43.46 7'- 0 34" 8'- 1 1 " T.O. Shtg. EL. 27.24 9'- 0 " 29 ' - 0 " 3'-0" Setback 3'-0" Setback 3 12 T.Pl. EL. 44.56 T.Pl.EL. 43.61 T.O. SheathingEL.36.40 7'-2 58" 8'- 2 " 8" 9"9" 7D 25 4 16 7A 2 4 3 1 4 16 Pro p e r t y L i n e 24 ' - 0 " Sloped Roof RidgeMaximum Height 29'-0" EL.46.25 Flat RoofMaximum Height 24'-0"EL.41.25 Pro p e r t y L i n e R-15 R-3016 R-15 R-38 16 R-15 16 16 R-30 USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYSAND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVESEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCHMINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOISTCAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREADINDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. 3'- 8 34" HP of GarageEL. 12.07 3'- 1 1 316 " Section "B"SCALE: 1/4" = 1'-0" BUILDING SECTIONS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A4.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-ELEV O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - E L E V A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Section "A"SCALE: 1/4" = 1'-0"Section "C"SCALE: 1/4" = 1'-0" 1. REFER TO STRUCTURAL ENGINEER DRAWINGS. 2. DETAILS REFERENCED IN THESE DRAWINGS ARE FOR CLARIFICATION OF THE ARCHITECTURAL DESIGN INTENT. REFER TO ENGINEERINGDRAWINGS PREPARED BY OTHERS FOR DETAILED INFORMATION. 3. UPPER FLOOR DIMENSIONS ARE TAKEN FROM TOP OF SUB FLOOR SHEATHING MATERIAL. SECTION NOTES SECTION KEY NOTES 1. TYPICAL ROOF ASSEMBLY: A: STANDING SEAM METAL ROOF BY: CUSTOM BILT METALSB: RATED UL-580 CLASS 90 C: TABLE 1 TILE WEIGHT - psfD: UNDERLAYMENTE: PLYWOOD SHEETING MATERIAL GLUED AND SCREWED .THICKNESS PER STRUCTURAL ENGINEER 2. TYPICAL FLOOR / CEILING ASSEMBLY A: FLOOR FINISH : SEE PLANB: GYPCRETEC: SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWEDTHICKNESS PER STRUCTURAL ENGINEERD: FLOOR JOISTS PER STRUCTURAL ENGINEERE: 2x WOOD FURRING (WHERE OCCURS).F: 5/8" GYPSUM WALLBOARD ( TYPE "X" WHERE REQUIRED) 3. TYPICAL DECK / CEILING ASSEMBLY A: STONE PAVERS OVER FULL MORTAR BEDB: SLOPED EPS DECK SYSTEMC: ELASTOMERIC SHEET WATERPROOFINGD: SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWEDTHICKNESS PER STRUCTURAL ENGINEERE: DECK JOIST PER STRUCTURAL ENGINEER 4. TYPICAL EXTERIOR WALL ASSEMBLY A: HARDBOARD SIDING BY "JAMES HARDIE" OR EQUALB: BRICK VENEER WHERE OCCURSC: WIRE LATH OVER MIN. 2 LAYERS GRADE "D" BUILDINGPAPERD: PLYWOOD SHEATHING OR SHEAR PANELS WHEREINDICATED ON STRUCTURAL PLANSE: 2x WALL FRAMING WITH INSULATION PER TITLE 24CALCULATIONSF: 5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED) 5. TYPICAL INTERIOR WALL ASSEMBLY A: 5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED)EACH SIDEB: 2x WOOD FRAMING PER STRUCTURAL PLANS 6. TYPICAL STAIR ASSEMBLY A: CONTINUOUS HANDRAIL SECURELY FASTENED TO WALL AT36" MAXIMUM AND 34" MINIMUM ABOVE TREAD AT NOSINGB: FINISH MATERIAL PER PLANC: 5/8" THICK RISERSD: 1 1/8" THICK TREADSE: MINIMUM (3) 2 x 12 STRINGERS AT STRAIGHT RUNF: (1) 2 x 8 AT FRONT AND BACK OF TREADS AT RADIAL RUNG: 2 x 8 JOISTS AT 16" O.C. MINIMUM AT LANDING. REFER TOSTRUCTURAL DRAWINGSH: POSITIVE CONNECTION TO FLOOR. REFER TO STRUCTURALPLANS FOR CONNECTION.I: 5/8" GYPSUM BOARD (TYPE "X" WHERE REQUIRED) ATWALLS AND CEILINGS OF ALL USABLE AREA UNDER STAIR SYMBOLX 7A CONCRETE SLAB. SEE STRUCTURAL DWGS. 7B GARAGE CONCRETE SLAB 7C CONCRETE STEM WALL 7D CONCRETE CAISSON 8 2x WOOD FRAMING 9 WOOD I-JOISTS. SEE STRUCTURAL DWGS 10 WOOD CONVENTIONAL FRAMED ROOF. SEESTRUCTURAL DRAWINGS. 11 2x CEILING JOIST 12 PLYWOOD ROOF SHEATHING. SEE STRUCT. DWGS.RADIANT BARRIER TO BE INSTALLED PERTITLE 24, REFER TO SHEET T-24.MM FORINSTALLATION METHODS 13 2 x T&G FLOOR SHEATHING 14 STEEL BEAMS WRAPPED IN WOOD 15 EXPOSED RAFTER TAIL 16 INSULATION, SEE TITLE 24 17 RIGID INSULATION 18 COPPER GUTTER / DOWNSPOUT 19 WOOD GUARDRAIL DETAILINGWITH HORIZONTAL STAINLESS STEELCABLE RAILING - PER DETAIL 12 / D4.2 20 GLASS GUARDRAIL 21 WOOD SIDING 22 WOOD CEILING / SOFFIT /FALSE CEILING BEAMS REFER TOREFLECTED CEILING PLANS 23 DRYWALL CEILING / SOFFITREFER TO REFLECTEDCEILING PLANS TYPICAL 24 WOOD DOORS & WINDOWS 25 LOUVERED BREAKAWAY WALL REFER TO T-24 SHEETS FOR CF1R FORMS AND COMPLIANCE INFORMATION INSULATION SCHEDULE BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.32 U-factor, 0.23 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.23 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-30 (2x4) plus R-15 (2x4) below roof deckRoof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 10.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storag: 5kWh; 95% charging/discharging BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4) No attic-Roof: R-30 (2x10)Roof attic: R-38 (2x4)Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 9.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storage: 5kWh; 95% charging/discharging Unit "A"Unit "B" NOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIALNOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL NOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL 61 8'- 1 " T.O.Sheathing EL.36.40 8'- 1 1 " T.O.SlabEL. 17.25 T.Pl.EL. 35.32 T.Pl.EL. 26.16 T.O. Shtg. EL. 27.24 B.O.SlabEL. 16.00 B.O.Hdr.EL. 43.46 7'- 0 34" T.Pl.EL. 44.02 7'- 7 12" Living Master Suite Setback 3'-0"3'-0" Setback 29 ' - 0 " 2'-0" 24 ' - 0 " T.O.Slab EL. 17.25 2'- 0 " 1 3 2 2 4 16 16 16 4 6" 3'- 0 34" 24 ' - 0 " Sloped Roof RidgeMaximum Height 29'-0" EL.46.25 Flat RoofMaximum Height 24'-0" EL.41.25 R-21 R-30 R-21 USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYSAND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVESEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCHMINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOISTCAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREAD INDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. Office Ba 4Bedroom 3 Entry B.O.Hdr. EL. 43.46 T.Pl.EL. 26.16 8'-1 1 " 7'- 0 34" T.O.SlabEL. 17.25 8'- 1 " 7'-7 12" T.O. SheathingEL.36.40 B.O.SlabEL. 16.00 T.Pl.EL. 35.32 Porch T.Pl.EL. 44.02 T.O. Shtg.EL. 27.24 17.25 T.O. Landing 8'- 0 34"Kitchen 312 3'-0" T.O.Slab EL. 17.25 29 ' - 0 " 3'-0" SetbackSetback 13.06 FS 1 1216 42 7A 2 11 8 16 3 3'- 0 34" 6" Sloped Roof Ridge Maximum Height 29'-0"EL.46.25 Flat RoofMaximum Height 24'-0" EL.41.25 Pro p e r t y L i n e Pro p e r t y L i n e 16 16 R-21 R-30 R-21 R-30 13.18 TC 13.10 TC 13.02 FS BUILDING SECTIONS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A4.2 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-ELEV O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - E L E V A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Section "D"SCALE: 1/4" = 1'-0" Section "F"SCALE: 1/4" = 1'-0" 1. REFER TO STRUCTURAL ENGINEER DRAWINGS. 2. DETAILS REFERENCED IN THESE DRAWINGS ARE FOR CLARIFICATION OF THE ARCHITECTURAL DESIGN INTENT. REFER TO ENGINEERINGDRAWINGS PREPARED BY OTHERS FOR DETAILED INFORMATION. 3. UPPER FLOOR DIMENSIONS ARE TAKEN FROM TOP OF SUB FLOOR SHEATHING MATERIAL. SECTION NOTES SECTION KEY NOTES 1. TYPICAL ROOF ASSEMBLY: A: STANDING SEAM METAL ROOF BY: CUSTOM BILT METALSB: RATED UL-580 CLASS 90 C: TABLE 1 TILE WEIGHT - psfD: UNDERLAYMENTE: PLYWOOD SHEETING MATERIAL GLUED AND SCREWED .THICKNESS PER STRUCTURAL ENGINEER 2. TYPICAL FLOOR / CEILING ASSEMBLY A: FLOOR FINISH : SEE PLANB: GYPCRETEC: SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWEDTHICKNESS PER STRUCTURAL ENGINEERD: FLOOR JOISTS PER STRUCTURAL ENGINEERE: 2x WOOD FURRING (WHERE OCCURS).F: 5/8" GYPSUM WALLBOARD ( TYPE "X" WHERE REQUIRED) 3. TYPICAL DECK / CEILING ASSEMBLY A: STONE PAVERS OVER FULL MORTAR BEDB: SLOPED EPS DECK SYSTEMC: ELASTOMERIC SHEET WATERPROOFINGD: SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWEDTHICKNESS PER STRUCTURAL ENGINEERE: DECK JOIST PER STRUCTURAL ENGINEER 4. TYPICAL EXTERIOR WALL ASSEMBLY A: HARDBOARD SIDING BY "JAMES HARDIE" OR EQUALB: BRICK VENEER WHERE OCCURSC: WIRE LATH OVER MIN. 2 LAYERS GRADE "D" BUILDINGPAPERD: PLYWOOD SHEATHING OR SHEAR PANELS WHEREINDICATED ON STRUCTURAL PLANSE: 2x WALL FRAMING WITH INSULATION PER TITLE 24CALCULATIONSF: 5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED) 5. TYPICAL INTERIOR WALL ASSEMBLY A: 5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED)EACH SIDEB: 2x WOOD FRAMING PER STRUCTURAL PLANS 6. TYPICAL STAIR ASSEMBLY A: CONTINUOUS HANDRAIL SECURELY FASTENED TO WALL AT36" MAXIMUM AND 34" MINIMUM ABOVE TREAD AT NOSINGB: FINISH MATERIAL PER PLANC: 5/8" THICK RISERSD: 1 1/8" THICK TREADSE: MINIMUM (3) 2 x 12 STRINGERS AT STRAIGHT RUNF: (1) 2 x 8 AT FRONT AND BACK OF TREADS AT RADIAL RUNG: 2 x 8 JOISTS AT 16" O.C. MINIMUM AT LANDING. REFER TOSTRUCTURAL DRAWINGSH: POSITIVE CONNECTION TO FLOOR. REFER TO STRUCTURALPLANS FOR CONNECTION.I: 5/8" GYPSUM BOARD (TYPE "X" WHERE REQUIRED) ATWALLS AND CEILINGS OF ALL USABLE AREA UNDER STAIR SYMBOLX 7A CONCRETE SLAB. SEE STRUCTURAL DWGS. 7B GARAGE CONCRETE SLAB 7C CONCRETE STEM WALL 7D CONCRETE CAISSON 8 2x WOOD FRAMING 9 WOOD I-JOISTS. SEE STRUCTURAL DWGS 10 WOOD CONVENTIONAL FRAMED ROOF. SEESTRUCTURAL DRAWINGS. 11 2x CEILING JOIST 12 PLYWOOD ROOF SHEATHING. SEE STRUCT. DWGS.RADIANT BARRIER TO BE INSTALLED PERTITLE 24, REFER TO SHEET T-24.MM FORINSTALLATION METHODS 13 2 x T&G FLOOR SHEATHING 14 STEEL BEAMS WRAPPED IN WOOD 15 EXPOSED RAFTER TAIL 16 INSULATION, SEE TITLE 24 17 RIGID INSULATION 18 COPPER GUTTER / DOWNSPOUT 19 WOOD GUARDRAIL DETAILINGWITH HORIZONTAL STAINLESS STEELCABLE RAILING - PER DETAIL 12 / D4.2 20 GLASS GUARDRAIL 21 WOOD SIDING 22 WOOD CEILING / SOFFIT /FALSE CEILING BEAMS REFER TOREFLECTED CEILING PLANS 23 DRYWALL CEILING / SOFFITREFER TO REFLECTEDCEILING PLANS TYPICAL 24 WOOD DOORS & WINDOWS 25 LOUVERED BREAKAWAY WALL REFER TO T-24 SHEETS FOR CF1R FORMS AND COMPLIANCE INFORMATION INSULATION SCHEDULE BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.32 U-factor, 0.23 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.23 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-30 (2x4) plus R-15 (2x4) below roof deckRoof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 10.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storag: 5kWh; 95% charging/discharging BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-38 (2x4)Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 9.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storage: 5kWh; 95% charging/discharging Unit "A"Unit "B" NOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL NOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL 62 T.O.Shtg.EL. 20.01 T.Pl.EL. 44.02 H.P. of GarageEL. 12.07 T.O.Sheathing EL.36.40 8'-1 " 8'- 1 1 " T.Pl. EL. 35.32 T.O.Slab EL. 17.25 T.O. Shtg.EL. 27.24 B.O.Slab EL. 16.00 T.Pl. EL. 26.16 7'-0 34" B.O.Hdr.EL. 43.46 7'- 7 12" T.Pl.EL. 18.93 T.Pl. EL. 28.01 6'- 1 0 12" 8'- 0 " 1'-1 " 7'-7 18" T.O.Shtg.EL. 28.90 1'-0 58" 10 34" 3'- 8 " T.O.RailingEL. 41.25 T.O.Shtg.EL. 37.54 Master Closet Master Suite Bath 2 Attic Roof Deck 8'-0 34" Two-Story Living Dine Carport Garage StorageBath 4Open Air Open Air Kitchen B.O.Hdr.EL. 27.07 7'-0 34" 7'- 0 34" 7'-0 34" B.O.Hdr.EL. 34.30 B.O.Hdr. EL. 34.30 2'-0"3'-0" 5'-0" 2nd Front Setback 29' - 0 " 20 3 3 20 2 20 6E 1 10 3 4 192 25 7B 7D 8 7A 7D 25 16 1616 6E 6C 6D 7'-0 34" 6" 3'-0 34" 8'-0 34" T.Pl.EL. 36.49 6" 6" 3'- 0 34" 3'-0 34" 6D 6C 3'- 8 " 3'- 8 "Spa byOthers 3'- 0 34" Pro p e r t y L i n e 24 ' - 0 " Sloped Roof RidgeMaximum Height 29'-0" EL.46.25 Flat RoofMaximum Height 24'-0" EL.41.25 Pro p e r t y L i n e 16 R-21 R-21 R-30 R-30 R-30 16 16 R-3016 R-21 6" 61516 " USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYSAND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVESEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCHMINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOISTCAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREAD INDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYSAND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVESEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCHMINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOISTCAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREAD INDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. 6'- 1 0 38" 19'-0" Minimum interiorclear dimension7'- 0 " C l e a r 4'-0" 7'- 0 " M i n i m u m i n t e r i o r cle a r d i m e n s i o n T.O.Sheathing EL.36.40 8'-1 " T.O.SlabEL. 17.25 T.Pl. EL. 26.16 8'- 1 1 " B.O.SlabEL. 16.00 T.O. Shtg.EL. 27.24 T.Pl.EL. 35.32 7'- 0 34" 7'- 7 12" T.Pl.EL. 44.02 B.O.Hdr.EL. 43.46 T.Pl.EL. 18.93 T.O.Shtg.EL. 20.01 H.P.of Garage EL. 12.07 3'- 8 " 6'- 1 0 12" T.Pl. EL. 28.01 8'- 0 " 7'- 7 18" 10 34" 1'- 1 " T.O.RailingEL. 41.25 T.O.Shtg.EL. 28.90 T.Pl.EL. 36.49 Master Bath Roof Deck Hall Bedroom 2Master Suite Office Roof Deck Kitchen Bedroom 3 Master BathMaster Suite Garage Carport Two-Story Living B.O.Hdr. EL. 27.07 7'-0 34" 7'- 0 34" 7'-0 34" Building Setback Dine Kitchen 2'-0"3'-0" 5'-0"15'-0" 2nd Front Setback 29 ' - 0 " 7D 7D 20 20 20 7A 6A 6D 1 2 4 2 8 4 2 25 6G 6A 6E 25 7A 3 16 16 16 6A 10 7'- 0 34" 6" 3'- 0 34" T.O.Shtg.EL.37.54 3'- 0 34" 6" 6" 3'- 0 34"3'- 8 " Flat RoofMaximum Height 24'-0" EL.41.25 24 ' - 0 " Sloped Roof RidgeMaximum Height 29'-0" EL.46.25 Pro p e r t y L i n e Pro p e r t y L i n e R-30 16 R-30 16 R-21 16 R-30 R-15 R-38 16 R-15 1R-30 16 R-30 1 10 Spa by Others USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYS AND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVESEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCH MINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOISTCAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREADINDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYSAND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVESEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCH MINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOISTCAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREAD INDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECKJOISTS. 19'-0" Minimum interiorclear dimension7'- 0 " C l e a r 7'- 0 " M i n i m u m i n t e r i o r cle a r d i m e n s i o n 4'-0" 6'- 1 0 38" Section "G"SCALE: 1/4" = 1'-0" BUILDING SECTIONS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A4.3 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-ELEV O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - E L E V A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Section "F"SCALE: 1/4" = 1'-0" 1. REFER TO STRUCTURAL ENGINEER DRAWINGS. 2. DETAILS REFERENCED IN THESE DRAWINGS ARE FOR CLARIFICATION OF THE ARCHITECTURAL DESIGN INTENT. REFER TO ENGINEERINGDRAWINGS PREPARED BY OTHERS FOR DETAILED INFORMATION. 3. UPPER FLOOR DIMENSIONS ARE TAKEN FROM TOP OF SUB FLOOR SHEATHING MATERIAL. SECTION NOTES SECTION KEY NOTES 1. TYPICAL ROOF ASSEMBLY: A: STANDING SEAM METAL ROOF BY: CUSTOM BILT METALSB: RATED UL-580 CLASS 90 C: TABLE 1 TILE WEIGHT - psfD: UNDERLAYMENTE: PLYWOOD SHEETING MATERIAL GLUED AND SCREWED .THICKNESS PER STRUCTURAL ENGINEER 2. TYPICAL FLOOR / CEILING ASSEMBLY A: FLOOR FINISH : SEE PLANB: GYPCRETEC: SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWEDTHICKNESS PER STRUCTURAL ENGINEERD: FLOOR JOISTS PER STRUCTURAL ENGINEERE: 2x WOOD FURRING (WHERE OCCURS).F: 5/8" GYPSUM WALLBOARD ( TYPE "X" WHERE REQUIRED) 3. TYPICAL DECK / CEILING ASSEMBLY A: STONE PAVERS OVER FULL MORTAR BEDB: SLOPED EPS DECK SYSTEMC: ELASTOMERIC SHEET WATERPROOFINGD: SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWEDTHICKNESS PER STRUCTURAL ENGINEERE: DECK JOIST PER STRUCTURAL ENGINEER 4. TYPICAL EXTERIOR WALL ASSEMBLY A: HARDBOARD SIDING BY "JAMES HARDIE" OR EQUALB: BRICK VENEER WHERE OCCURSC: WIRE LATH OVER MIN. 2 LAYERS GRADE "D" BUILDINGPAPERD: PLYWOOD SHEATHING OR SHEAR PANELS WHEREINDICATED ON STRUCTURAL PLANSE: 2x WALL FRAMING WITH INSULATION PER TITLE 24CALCULATIONSF: 5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED) 5. TYPICAL INTERIOR WALL ASSEMBLY A: 5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED)EACH SIDEB: 2x WOOD FRAMING PER STRUCTURAL PLANS 6. TYPICAL STAIR ASSEMBLY A: CONTINUOUS HANDRAIL SECURELY FASTENED TO WALL AT36" MAXIMUM AND 34" MINIMUM ABOVE TREAD AT NOSINGB: FINISH MATERIAL PER PLANC: 5/8" THICK RISERSD: 1 1/8" THICK TREADSE: MINIMUM (3) 2 x 12 STRINGERS AT STRAIGHT RUNF: (1) 2 x 8 AT FRONT AND BACK OF TREADS AT RADIAL RUNG: 2 x 8 JOISTS AT 16" O.C. MINIMUM AT LANDING. REFER TOSTRUCTURAL DRAWINGSH: POSITIVE CONNECTION TO FLOOR. REFER TO STRUCTURALPLANS FOR CONNECTION.I: 5/8" GYPSUM BOARD (TYPE "X" WHERE REQUIRED) ATWALLS AND CEILINGS OF ALL USABLE AREA UNDER STAIR SYMBOLX 7A CONCRETE SLAB. SEE STRUCTURAL DWGS. 7B GARAGE CONCRETE SLAB 7C CONCRETE STEM WALL 7D CONCRETE CAISSON 8 2x WOOD FRAMING 9 WOOD I-JOISTS. SEE STRUCTURAL DWGS 10 WOOD CONVENTIONAL FRAMED ROOF. SEESTRUCTURAL DRAWINGS. 11 2x CEILING JOIST 12 PLYWOOD ROOF SHEATHING. SEE STRUCT. DWGS.RADIANT BARRIER TO BE INSTALLED PERTITLE 24, REFER TO SHEET T-24.MM FORINSTALLATION METHODS 13 2 x T&G FLOOR SHEATHING 14 STEEL BEAMS WRAPPED IN WOOD 15 EXPOSED RAFTER TAIL 16 INSULATION, SEE TITLE 24 17 RIGID INSULATION 18 COPPER GUTTER / DOWNSPOUT 19 WOOD GUARDRAIL DETAILINGWITH HORIZONTAL STAINLESS STEELCABLE RAILING - PER DETAIL 12 / D4.2 20 GLASS GUARDRAIL 21 WOOD SIDING 22 WOOD CEILING / SOFFIT /FALSE CEILING BEAMS REFER TOREFLECTED CEILING PLANS 23 DRYWALL CEILING / SOFFITREFER TO REFLECTEDCEILING PLANS TYPICAL 24 WOOD DOORS & WINDOWS 25 LOUVERED BREAKAWAY WALL REFER TO T-24 SHEETS FOR CF1R FORMS AND COMPLIANCE INFORMATION INSULATION SCHEDULE BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.32 U-factor, 0.23 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.23 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-30 (2x4) plus R-15 (2x4) below roof deckRoof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 10.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storag: 5kWh; 95% charging/discharging BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-38 (2x4)Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HVAC - HEAT PUMPHeating: 9.5 HSPFCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV.ZVRXWKHDVWIDFLQJƒWLOWBattery Storage: 5kWh; 95% charging/discharging Unit "A"Unit "B" NOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL NOTE: BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL 63 8'-1 " T.O.Shtg.EL. 27.24 T.O.Sheathing EL.36.40 8'- 1 1 " T.Pl. EL. 35.32 T.O.SlabEL. 17.25 T.Pl. EL. 26.16 B.O.SlabEL. 16.00 7'-0 34" B.O.Hdr.EL. 43.46 7'- 7 12" T.Pl.EL. 44.02 3'-0" Setback 3'-0" Setback 29' - 0 " 2'-0 " T.O.Slab EL. 17.25 24 ' - 0 " 2'-0" FS 18 114 312 5 13 14 9 6 14 7 6 9 17 6" 3'- 0 34" 3'- 0 34" 13 6" 3'-0 34" 13 6" Flat RoofMaximum Height 24'-0" EL.41.25 Sloped Roof RidgeMaximum Height 29'-0" EL.46.25 24 ' - 0 " 21 Pro p e r t y L i n e Pro p e r t y L i n e T.O. SheathingEL.36.40 1034" 8'- 1 " T.O.Slab EL. 17.25 T.Pl.EL. 35.32 T.Pl.EL. 26.16 8'-1 1 " T.O. Shtg.EL. 27.24 B.O.SlabEL. 16.00 7'- 0 34" T.Pl.EL. 44.02 B.O.Hdr. EL. 43.46 7'-7 12" T.Pl. EL. 18.93 H.P. of GarageEL. 12.07 T.O.Shtg. EL. 20.01 7'-7 18" 1'- 0 58" 6'-1 0 12" T.O.Shtg.EL. 28.90 8'-0 " 3'- 8 " 1'-1 " T.Pl.EL. 28.01 T.O.Shtg. EL. 37.54 T.O.Railing EL. 41.25 7'- 0 34" B.O.Hdr.EL. 27.07 7'- 0 34" 8'- 0 34" 24' Above T.O. Slab 29 ' - 0 " 5'-0" 2'-0"3'-0" 2nd Front Setback 15'-0" Building Setback 2'- 0 " 4'-0" 7'- 0 34" 7'- 0 34" 7'- 0 34" 7'- 0 34" 7'- 0 34" 7'- 1 18" 1 7 13 13 13 2 1 914 14 14 18 6 9 14 20 8 2 65 6 14 9 3 12 6" 3'-0 34" 6" 3'- 0 34" 3'-6 34" 18 7'- 0 34" 8'- 0 34" 3'-6 " 3'- 0 " 1 T.O.Shtg.EL. 36.49 15'-0" Building Setback 24' - 0 " Sloped Roof Ridge Maximum Height 29'-0"EL.46.25 Flat RoofMaximum Height 24'-0"EL.41.25 Pro p e r t y L i n e Pro p e r t y L i n e 4" 12 Right Side Elevation SCALE: 1/4" = 1'-0" BUILDING ELEVATIONS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A5.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-ELEV O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - E L E V A u g u s t 1 5 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Front Elevation SCALE: 1/4" = 1'-0" ELEVATION NOTES ROOFING MATERIAL: ELEVATION KEY NOTES GUTTERS /DOWNSPOUTS:5" DIAMETER HALF ROUND COPPER GUTTERS ANDDOWNSPOUTS - ALL COPPER TO BE DARK BROWN IN COLOR BUILDING PAPER: PROVIDE A MINIMUM OF TWO LAYERS OF GRADE "D"PAPER OVER ALL WOOD BASED SHEATHING AND UNDER ALL GROUT BASED MASONRY VENEERS. VAPOR BARRIER:PROVIDE VAPOR BARRIER AROUND ALL WALLPENETRATIONS INCLUDING DOORS AND WINDOWSPER DETAILS CHIMNEYTERMINATION:CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANYPORTION OF THE BUILDING WITH IN 10'-0", BUT SHALL NOT BE LESS THAN 3' ABOVE THE HIGHEST POINT WHERETHE CHIMNEY PASSES THROUGH THE ROOF. WOOD SIDING:HARDBOARD SIDING BY "JAMES HARDIE"PAINTED. REFER TO COLOR SCHEME WOOD TRIM:2x WOOD TRIMPAINTED. REFER TO COLOR SCHEME 1 STANDING SEAM METAL ROOF 5 9 3 1 x 9 VERTICAL WOOD SIDING WITH WOOD DOORS & WINDOWS COLOR - PAINTED REFER TO COLOR SCHEME EXPOSED WOOD BEAM / CORBELCOLOR - PAINTED 10 GARAGE DOOR :COLOR - PAINTED 3/8" STRAIGHT GROVE 6 REFER TO COLOR SCHEME COLOR - PAINTED 4 7 CHIMNEY CAP - COPPERCOLOR - NATURAL AGED 8 WOOD ENTRY DOORCOLOR - PAINTED 2 EXPOSED WOOD RAFTER TAILS COLOR - PAINTED 11 12 WOOD GATE : OPEN METAL GUARDRAIL ANDHANDRAIL DETAILING COLOR - PAINTEDREFER TO COLOR SCHEME 18 1 x 9 HORIZONTAL WOOD SIDINGWITH 3/8" STRAIGHT GROVECOLOR - PAINTED 15 GUTTERS / DOWNSPOUT 14 WOOD DETAILINGCOLOR - STAIN DIRECT VENT TERMINATION CAPREFER TO MANUFACTURER SPECIFICATIONS 17 WOOD SOFFIT DETAILINGCOLOR - STAIN16 HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROMSTREET (MINIMUM 4" HIGH x 1" WIDE) CRC R31919 STANDING SEAM PANEL ROOFBY:"CUSTOM-BILT METALS" CB-2000 2" PREFINISHED ALUMINUMRATED UL-580 CLASS 90TESTED ASTM E-1592, E-1680 & E-1646 REFER TO COLOR SCHEME EXPOSED WOOD BOXED COLUMNCOLOR - PAINTED REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME 13 GLASS GUARDRAIL DETAILING LOUVERED BREAKAWAY WALL SHALL COMPLY WITH:20 ASCE 24 Sections 4.6.1 & 4.6.2ASCE 7 Section 5.3.3 EXTERIOR LIGHT FIXTURE 21 BRICK VENEER:ADHERED 3/4" - 2" THICK CUT BRICK VENEER BY WESTLAKE ROYAL STONE OR APPROVEDEQUAL, ICC REPORT No. ESR-1364PAINTED WHITE WITH FLUSH GROUT. VENEER SHALL NOT EXCEED 15 POUNDS PER SQ. FT. ADHERED BRICK VENEER 64 T.Pl. EL. 18.93 HP of GarageEL. 12.07 T.O.Shtg.EL. 20.01 6'-1 0 12" T.Pl.EL. 28.01 7'- 7 18" 1034" 1'- 0 58" T.O.Railing EL. 41.25 T.O.Shtg.EL. 37.54 1'- 1 " 8'-0 " T.O.Shtg.EL. 28.90 7'- 0 34" B.O.Hdr.EL. 27.07 3 12 T.O.Slab EL. 17.25 29 ' - 0 " 3'-0"3'-0" SetbackSetback 7'- 0 34" 638" 7 1 14 5 12 14 9 6 13 14 14 10 5 Sim. 3'- 8 " 6'-7 58" T.Pl.EL. 36.49 3'- 6 34" Sloped Roof RidgeMaximum Height 29'-0"EL.46.25 Flat RoofMaximum Height 24'-0"EL.41.25 24' - 0 " Pro p e r t y L i n e Pro p e r t y L i n e 21 8'- 1 " 8'- 1 1 " T.O. Shtg. EL. 27.24 B.O.SlabEL. 16.00 T.O.SheathingEL.36.40 T.Pl.EL. 26.16 T.O.SlabEL. 17.25 Sloped Roof Ridge Maximum Height 29'-0"EL.46.25 T.Pl.EL. 35.32 7'- 0 34" B.O.Hdr. EL. 43.46 T.Pl.EL. 44.02 7'- 7 12" H.P. of Garage EL. 12.07 T.O.Shtg. EL. 20.01 T.Pl.EL. 18.93 6'- 1 0 12" 8'- 0 " 10 34"T.Pl.EL. 28.01 T.O.Shtg. EL. 37.54 7'- 7 18" 3'- 8 " T.O.Shtg.EL. 28.90 1'-0 58" T.O.RailingEL. 41.25 T.Pl.EL. 36.49 7'-0 34" B.O.Hdr. EL. 27.07 7'- 0 34" 2'-0"3'-0" 5'-0"15'-0" Pro p e r t y L i n e Building Setback 2nd Front Setback 29 ' - 0 " 2'- 0 " 24' AboveT.O. Slab 7'- 0 34" 6'- 0 34" 7'- 0 34" 3'- 8 " 6" 3'- 0 34" 1 2 14 1 14 96 20 20 6 14 14 14 13 13 13 8 12 5 14 14 8 3 12 7'- 0 34" 8'- 0 34" 4'-0" 7 6" 3'- 0 34" 3'- 8 " 6'-8 34" 6'- 0 34" 3'- 8 " 3'-6 34" 6" 3'- 0 34" 5'- 1 0 58" 7'- 0 34" 3'- 0 " 4'-0" 4'-6 " Dryer Ventto outside air Dryer Exhaust duct shall terminate noless than 3'-0" from openings into thebuilding Dryer Ventto outside air 24 ' - 0 " Flat RoofMaximum Height 24'-0" EL.41.25 Pro p e r t y L i n e 4" 13 6'- 3 " M a x . 4'- 0 " M i n . Left Side Elevation BUILDING ELEVATIONS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A5.2 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-ELEV O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - E L E V A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Rear Elevation SCALE: 1/4" = 1'-0" ELEVATION NOTES ROOFING MATERIAL: ELEVATION KEY NOTES GUTTERS / DOWNSPOUTS: 5" DIAMETER HALF ROUND COPPER GUTTERS AND DOWNSPOUTS - ALL COPPER TO BE DARK BROWNIN COLOR BUILDING PAPER: PROVIDE A MINIMUM OF TWO LAYERS OF GRADE "D"PAPER OVER ALL WOOD BASED SHEATHING ANDUNDER ALL GROUT BASED MASONRY VENEERS. VAPOR BARRIER:PROVIDE VAPOR BARRIER AROUND ALL WALL PENETRATIONS INCLUDING DOORS AND WINDOWSPER DETAILS CHIMNEYTERMINATION:CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANYPORTION OF THE BUILDING WITH IN 10'-0", BUT SHALL NOTBE LESS THAN 3' ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF. WOOD SIDING:HARDBOARD SIDING BY "JAMES HARDIE" PAINTED. REFER TO COLOR SCHEME WOOD TRIM:2x WOOD TRIMPAINTED. REFER TO COLOR SCHEME 1 STANDING SEAM METAL ROOF 5 9 3 1 x 9 VERTICAL WOOD SIDING WITH WOOD DOORS & WINDOWS COLOR - PAINTED REFER TO COLOR SCHEME EXPOSED WOOD BEAM / CORBELCOLOR - PAINTED 10 GARAGE DOOR :COLOR - PAINTED 3/8" STRAIGHT GROVE 6 REFER TO COLOR SCHEME COLOR - PAINTED 4 7 CHIMNEY CAP - COPPERCOLOR - NATURAL AGED 8 WOOD ENTRY DOORCOLOR - PAINTED 2 EXPOSED WOOD RAFTER TAILS COLOR - PAINTED 11 12 WOOD GATE : OPEN METAL GUARDRAIL ANDHANDRAIL DETAILING COLOR - PAINTEDREFER TO COLOR SCHEME 18 1 x 9 HORIZONTAL WOOD SIDINGWITH 3/8" STRAIGHT GROVECOLOR - PAINTED 15 GUTTERS / DOWNSPOUT 14 WOOD DETAILINGCOLOR - STAIN DIRECT VENT TERMINATION CAPREFER TO MANUFACTURER SPECIFICATIONS 17 WOOD SOFFIT DETAILINGCOLOR - STAIN16 HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROMSTREET (MINIMUM 4" HIGH x 1" WIDE) CRC R31919 STANDING SEAM PANEL ROOFBY:"CUSTOM-BILT METALS"CB-2000 2" PREFINISHED ALUMINUMRATED UL-580 CLASS 90 TESTED ASTM E-1592, E-1680 & E-1646REFER TO COLOR SCHEME EXPOSED WOOD BOXED COLUMNCOLOR - PAINTED REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME 13 GLASS GUARDRAIL DETAILING LOUVERED BREAKAWAY WALL SHALL COMPLY WITH:20 ASCE 24 Sections 4.6.1 & 4.6.2ASCE 7 Section 5.3.3 EXTERIOR LIGHT FIXTURE 21 BRICK VENEER:ADHERED 3/4" - 2" THICK CUT BRICK VENEERBY WESTLAKE ROYAL STONE OR APPROVED EQUAL, ICC REPORT No. ESR-1364PAINTED WHITE WITH FLUSH GROUT. VENEERSHALL NOT EXCEED 15 POUNDS PER SQ. FT.ADHERED BRICK VENEER SCALE: 1/4" = 1'-0" 65 Crawl Space Garage HB / withShut Off Garage DoorOpener FG GFI LED LED LED Connect toPhotocell GFIWP SV PB S Connect toLightsabove Stair treadLights Typ. GFIWP Plug forElec. CarVerify location FGUnit B Unit A GFIWP GFIWP SV LED LED S CW Surface mounted LEDFixture typ. Connect to Photocell GFIWP GFIWP Stair tread Lights Typ. Stair treadLights Typ. Connect toPhotocell LEDLED LEDLED LED LED Side Yard Lights Typ. LEDLED LED LED LED LED LED HB Pdr Dine Entry Unit "A" Kitchen Deck Ba 4 pantry Bed 3 Kit Family Provide in Kitchen local exhaust systemvented to outdoorswith rate = 250 cfm Two New 225 AMP servicepanels are proposedfor Unit "A" & Unit "B"ground from UFER to gas to coldwater with1/0 AWG AboveMantelKEY FG TV FG LED GFIWP HB GFI GFIS PB GFI GFI S SS LED LED LED LED LED LED LED S D CW GFI SSV GF I S S LED SSSD D 3V 3D Stair treadLights Typ. Connect to Photocell SSConnect toLightsabove Connect to Lights below LED PB GFIWP 3D3D GFIWP SS PB 3D SD CM SD CM SSS GFI FL/WP V S3D TV S SD CM Connect to Photocell Stair treadLights Typ. HB Stair treadLights Typ.Connect toPhotocell SV Stair tread Lights Typ. S 3D Stair tread Lights Typ. Connect toLightsabove GFIWP TV SS GFI GFI GFI GFIGFIPB FG GFI GFI CW D D LED LED LED LED Range outlet shallbe 240V Capable GFI Unit "B"LED HB S Switch for Blinds LED LED GFIWP LEDLED Outlet for Blinds LED LED LED LED LED LEDLED LED FG GFIWP LED SSD J-Boxfor Fan S GFIWP SD HB S Outlet belowhandrail forChristmasLights T T J-Boxfor Fan Sitting Bench Sitting Bench J-Boxfor Fan SD Outlet belowhandrail for ChristmasLights GFI GFI Provide in Kitchen local exhaust systemvented to outdoorswith rate = 280 cfm GFI Range outlet shall be 240V Capable IAQ Fan50 cfm IAQ Fan30 cfm Garage Level Electrical Plan SCALE: 1/4" = 1'-0" GARAGE & MAIN LEVEL ELECTRICAL PLAN PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A6.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions ELECTRICAL LEGEND FL KEY F.G. HB SD PB CM POWERAPPLIANCE TV T S S3 S4 SD SV MINIMUM WHOLE BUILDING MECHANICAL VENTILATION(THE FOLLOWING INFORMATION AND CALCULATIONS ARE PER ASHRAE 62.2 RESIDENTIAL INDOOR AIR QUALITYAND MECHANICAL VENTILATION REPORT - REFER TO REPORT FOR MORE INFORMATION) CONTINUOUS VENTILATION CALCULATION: (MIN. AIRFLOW MEASURED @ 0.25" FOR CONTINUOUS OPERATION)(CFA / 100) + 7.5 (# OF BEDROOMS + 1) = VENTILATION RATE (MINIMUM CFM @ 0.25") CLG WHOLE BUILDING VENTILATION SYSTEM SUMMARY ALL LOW-RISE RESIDENTIAL BUILDING ARE REQUIRED TO HAVE A VENTILATION SYSTEM AND SATISFY OTHER REQUIREMENTSTO ACHIEVE ACCEPTABLE INDOOR AIR QUALITY (IAQ). THE ENERGY COMMISSION ADOPTED THE REQUIREMENTS OF ASHRAESTANDARD 62.2-2007, EXCEPT THAT OPENING AND CLOSING WINDOWS (ALTHOUGH PERMITTED BY ASHRAE) IS NOT ANACCEPTABLE OPTION FOR PROVIDING WHOLE-BUILDING VENTILATION IN CALIFORNIA. THE FOLLOWING BULLET POINTS SUMMARIZE THE KEY REQUIREMENTS FOR MOST RESIDENCE: 1. A WHOLE BUILDING MECHANICAL VENTILATION SYSTEM SHALL BE PROVIDED. 2. KITCHENS AND BATHROOMS SHALL HAVE LOCAL EXHAUST SYSTEMS VENTED TO THE OUTDOORS. 3. CLOTHES DRYERS SHALL BE VENTED TO THE OUTDOORS. 4. VENTILATION AIR SHALL COME FROM OUTDOORS AND SHALL NOT BE TRANSFERRED FROM THE ADJACENT DWELLING UNITS, GARAGES OR CRAWL SPACES. 5. VENTILATION SYSTEM CONTROLS SHALL BE LABELED AND THE HOME OWNER SHALL BE PROVIDED WITH INSTRUCTIONS ON HOW TO OPERATE THE SYSTEM. 6. COMBUSTION APPLIANCES SHALL BE PROPERLY VENTED AND AIR SYSTEMS SHALL BE DESIGNED TO PREVENT BACK DRAFTING. 7. THE WALL AND OPENINGS BETWEEN THE HOUSE AND THE GARAGE SHALL BE SEALED. 8. HABITABLE ROOMS SHALL HAVE WINDOWS WITH A VETILAION AREA OF AT LEAST 4% OF THE FLOOR AREA. 9. MECHANICAL SYSTEMS INCLUDING HEATING AND AIR CONDITIONING SYSTEMS THAT APPLY AIR TO HABITABLE SPACES SHALL HAVE MERV 6 FILTERS OR BETTER. 10. AIR INLET (NOT EXHAUST) SHALL BE LOCATED AWAY FROM KNOWN CONTAMINANTS. 11. AIR MOVING EQUIPMENT USED TO MEET EITHER THE WHOLE BUILDING VENTILATION REQUIREMENTS OR THE LOCAL VENTILATION EXHAUST REQUIREMENT SHALL BE RATED IN TERMS OF AIRFLOW AND SOUND: A. ALL CONTINUOUSLY OPERATING FANS SHALL BE RATED AT A MAXIMUM OF 1.0 SONE.B. INTERMITTENTLY OPERATED WHOLE BUILDING VENTILATION FANS SHALL BE RATED AT A MAXIMUM OF 1.0 SONE.C. INTERMITTENTLY OPERATED LOCAL EXHAUST FANS SHALL BE RATED AT A MAXIMUM OF 3.0 SONE.D. REMOTELY OPERATED AIR-MOVING EQUIPMENT (MOUNTED OUTSIDE OF HABITABLE SPACES) NEED TO MEET SOUND REQUIREMENTS IF THERE IS AT LEAST 4 FEET OF DUCTWORK BETWEEN THE FAN AND THE INTAKE GRILL. 12. A MINIMUM INTERMITTENT VENTILATION AIRFLOW OF 100 CFM IS REQUIRED FOR THE KITCHEN RANGE HOOD AND A MINIMUM INTERMITTENT VENTILATION AIRFLOW OF 50 CFM IS REQUIRED FOR THE BATH FAN. ELECTRICAL PLAN NOTES 9. KITCHEN COUNTER CIRCUITS SHALL BE DIVIDEDINTO TWO SEPARATE CIRCUITS. ALL SMALL APPLIANCE CIRCUIT SHALL BE ON A MIN. 20 AMP.CIRCUIT. REFRIGERATORS CANNOT BE ON EITHEROF THESE CIRCUITS, BUT MAY BE ON CIRCUITSWITH THE RANGE CLOCK AND/OR HOOD. 10. RECESSED FIXTURES - MUST BE RATED FORINSULATION CONTACT (IC-RATED), AIRTIGHT(ASTME283) AND SEALED W/ A GASKET OR CAULK BETWEEN HOUSE AND CEILING ALL HIGH-EFFICACYAND LOW-EFFICACY MUST BE CONTROLLEDSEPARATELY 11. GFI RECEPTACLES IN GARAGE OR AT PATIO SHALLNOT BE ON KITCHEN COUNTER CIRCUIT. 12. LIGHTS IN CLOTHES CLOSETS TO COMPLY ASFOLLOWS:A. CLOSET LESS THAN 70 SQ. FT. HAVE NOLIGHTING OR CONTROL REQUIREMENTS.B. CLOSET GREAT THAN 70 SQ. FT. EACHAND EVERY PERMANENTLY INSTALLEDLIGHTING FIXTURE MUST COMPLY WITHTHE STANDARDS, BY MEANS OF BEINGHIGH EFFICACY, CONTROLLED BY MANUAL-ON OCCUPANCY SENOR, ORCONTROLLED BY A DIMMER. 13. FIXTURES USED TO MEET FLUORESCENTREQUIREMENTS SHALL NOT CONTAINMEDIUM-BASED INCANDESCENT LAMP SOCKETS. 14. FIXTURES THAT WEIGH MORE THAN 6 POUNDS OREXCEED 16-INCHES IN ANY DIMENSION SHALL NOTBE SUPPORTED BY THE SCREW SHELL OF A LAMPHOLDER. 15. ALL BATHROOM FANS TO BE 50 CFM'S MINIMUM.PROVIDE A MINIMUM OF FIVE (5) AIR CHANGES PERHOUR. 16. SDG&E APPROVAL IS REQUIRED FOR METERLOCATION PRIOR TO INSTALLATION. 17. RECEPTACLES SHALL BE INSTALLED SO THAT NOPOINT ALONG THE FLOOR LINE IN ANY WALL SPACEIS MORE THAT 6 FEET, MEASURED HORIZONTALLY,FROM AN OUTLET IN THAT SPACE. RECEPTACLEOUTLETS SHALL, INSOFAR AS PRACTICABLE, BESPACED EQUAL DISTANCES APART. (C.B.C. 210-52) 18. MINIMUM OF (1) 20 AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM. CEC 210-11(C)(3). 1. ALL ELECTRICAL WORK SHALL BE INCONFORMANCE WITH LOCALLY ADOPTED BUILDING CODE AND ADMENDMENTS. ALLELECTRICAL WORK SHALL ALSO CONFORMWITH THE LOCAL BUILDING ENERGYEFFICIENCY STANDARDS. 2. PROVIDE SERVICE PANEL WITH U.F.E.R.GROUND AND BARE COPPER WIRE BONDED TOUNDERGROUND COLD WATER PIPE. 3. PROVIDE RECEPTACLE AND GAS SUPPLY TOFORCED AIR UNIT. PROVIDE A QUICKDISCONNECT AT ALL MECHANICALEQUIPTMENT AND A SERVICE RECEPTACLEWITHIN 25 FEET. 4. PROVIDE APPROVED CEILING MOUNTED SMOKEDETECTORS AS SHOWN ON PLAN WITHPERMANENT WIRING AND BATTERY BACK- UP,LOCATED A MIN. OF 3' IN FRONT OF THEKITCHEN SIDE OF THE RETURN AIR GRILL.PROVIDE AN ADDITIONAL DETECTOR NEAR THETOP OF A VAULTED OR HIGH CEILING, IF THEVAULT IS 24" HIGHER THAN THE HALLWAY TOTHE BEDROOMS. DETECTORS SHALL BEINSTALLED A MINIMUM OF 24" FROM ROOMREGISTERS AND SHALL BE INTERCONNECTED. 5. G.F.C.I. PROTECTION PER CEC 210.8(A) TO ALLALL 120 VOLTS, 15 AND 20 AMP RECEPTACLESINSTALLED IN THE FOLLOWING LOCTIONS:A. BATHROOMSB. GARAGES AND ACCESSORY BUILDINGSC. OUTDOORSD. CRAWL SPACESE. UNFINISHED BASEMENTSF. KITCHENS, WHERE THE RECEPTACLESARE INSTALLED TO SERVE THECOUNTERTOPSG. SINKS, LOCATED IN OTHER THANKITCHENS WHERE RECEPTACLES ARELOCATED WITHIN 6 FEET OF THEOUTSIDE EDGE OF THE SINK. (UTILITY,LAUNDRY, WET BARS, ETC.) 6. PROVIDE SEPARATE CIRCUITS FOR ALLANTICIPATED LOADS AS REQUIRED BY CODEGREATER THAN 20 AMPS. 7. KITCHEN GENERAL LIGHTING - HIGH EFFICACYOR UP TO 50% OF THE TOTAL WATTAGE CANBE LOW EFFICACY ALL HIGH-EFFICACY ANDLOW-EFFICACY MUST BE CONTROLLEDSEPARATELY 8. BATHROOMS - HIGH EFFICACY OR MANUAL-ONOCCUPANCY SENSOR 19. PROVIDE A MINIMUM OF 1-20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. CEC 210-11(C)(2) 20. PROVIDE A MINIMUM OF 2-20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN COUNTERTOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE BALANCED. CEC 210-11(C)(1) 21. FIELD INSPECTOR TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TOCONCRETE PLACEMENT. 22. ALL STAIRS SHALL HAVE AN ILLUMINATIONLEVEL ON TREADS RUNS OF NOT LESSTHAN 1 FOOT CANDLE (11 lux) CBC 1205.4 23. PROVIDE IN KITCHENS LOCAL EXHAUST SYSTEMVENTED TO OUTDOORS WITH RATE = 100 CFM. A MAXIMUM SOUND RATING OF 3 SONEFOR INTERMITTEN OPERATION IS REQUIRED 24. SMOKE DETECTORS ARE NOT TO BE LOCATED INKITCHEN, GARAGE, OR WITHIN 3 FEET FROMDOOR TO KITCHEN OR BATHROOM OR SUPPLY AIR REGISTERS 25. ALL DOORS FROM HOUSE TO POOL YARD MUST BEEQUIPPED WITH ALARM OR PROVIDE AN ALTERNATE DROWNING PREVENTION SAFETY FEATURE PER CBC 3109.4.4.2 26. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH AN EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 CFM. A MAXIMUM SOUND RATING OF 3 SONE FORINTERMITTEN OPERATION, BE LISTED AS ENERGYSTATE RATED AND CONTROLLED BY A HUMIDITYCONTROL UNLESS EXEMPTED ELSEWHEREDUCTLESS FANS ARE UNACCEPTABLE CBC 1203.4.2.1, CMC T-4-4. 27. FOR CFM OF EXHAUST FANS AND SONES LEVELSREFER TO MECHANICAL 28. ALL EXHAUST FANS SHALL BE CONTROLLED BY A HUMIDISTAT. 29. AIR MOVING EQUIPMENT MUST MEET REQUIREMENTS FOR SOUND OF 1 SONE FOR CONTINUOUS USE, OR 3 SONE FOR INTERMITTENT USE. 30. THE FOLLOWING SPECIFICATIONS FOR ELECTRICAL DEVICES INSTALLED IN DWELLINGS: CEC ARTICLE 210 & 406A) RECEPTACLES SHALL BE LISTED AS TAMPER-RESISTANT FOR ALL 15 AND 20 AMPERE RECEPTACLES IN DWELLING UNIT FAMILY, DINING, LIVING, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS AND AREAS PER CEC SECTION 406.12B) WEATHER RESISTANT TYPE FOR RECEPTACLES INSTALLED IN DAMP OR WET LOCATIONS. (OUTSIDE)C) ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION (AFCI) IS REQUIREC FOR ALL 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT FAMILY, DINING, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS AND AREAS PER CEC SECTION 210.12(A) 31. CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL TERMINATEOUTSIDE THE BUILDING AND HAVE A BACK-DRAFT DAMPER.EXHAUST DUCT IS LIMITED TO 14' WITH TWO ELBOWS. THISSHALL BE REDUCED 2' FOR EVERY ELBOW IN EXCESS OF TWOOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION(504.4 CMC) 32. SMOKE DETECTORS AND CARBON MONOXIDE ALARM INACCORDANCE WITH SECTION R315.1 SHALL BE INSTALLED ASFOLLOWS:A. WHERE MORE THAN SMOKE DETECTOR /CARBON MONOXIDE ALARM IS REQUIRED TO BEINSTALLED WITHIN THE DWELLING UNIT ORWITHIN A SLEEPING UNIT THE ALARM SHALL BEINTERCONNECTED IN A MANNER THATACTIVATION OF ONE ALARM SHALL ACTIVATEALL OF THE ALARMS IN THE INDIVIDUAL UNIT.B. SMOKE DETECTORS / CARBON MONOXIDEALARMS SHALL RECEIVE THEIR PRIMARYPOWER FROM THE BUILDING WIRING (HARDWIRED) AND SHALL BE EQUIPPED WITH ABATTERY BACK-UP. 33. LED LUMINAIRES MUST BE CERTIFIED AND QUALIFIED AS HIGH EFFICACY. 34. AT LEAST ONE HIGH EFFICACY LUMINAIRE IN EACH BATHROOM IS REQUIRED. SECTION 150.0(K) 35. HIGH EFFICACY LUMINARIES FOR RESIDENTIAL LIGHTING SHALLCONTAIN ONLY HIGH EFFICACY LAMPS SHALL NOT CONTAIN A MEDIUM SCREW BASE SOCKET (E24/E26). A HIGH EFFICACY LAMP HAS A LAMP EFFICACY THAT IS NO LOWER THAN EFFICACIES CONTAINED IN TABLE 150-C. BALLASTS FOR LAMPS RATED 13 WATTS OR GREATER SHALL BE ELECTRONIC AND SHALLHAVE AN OUTPUT FREQUENCY NO LESS THAN 20 kHz. 36. ALL HIGH EFFICACY LUMINARIES (INCLUDING RECESSED CAN FIXTURES) SHALL CONTAIN PIN BASED SOCKETS UNLESS ESPECIFICALLY APPROVED BY THE ENERGY COMMISION. [2008 EES 150(k) 1] 37. ALL NEW HVAC EQUIPMENT MUST HAVE AN EFFICIENCY RATING OF EER 13 [2008 EES 112] 38. ALL HEATING SYSTEMS SHALL HAVE AN AUTOMATIC THERMOSTAT WITH A CLOCK MECHANISM WHICH THE BUILDING OCCUPANT CAN MANUALLY PROGRAM TO AUTOMATICALLY SET BACK THE THERMOSTAT SET POINTS AT LEAST 4 PERIODS WITHIN 24 HOURS [2008 EES 150(i)] 39. ALL POWER AND LIGHTING OUTLETS IN FAMILY ROOM, PARLORS, LIBRARIES, DEN, BEDROOM, SUNROOMS, RECREATION ROOMS, HALLWAYS AND SIMILAR AREAS ARE TO BE PROTECTED BY A "LISTED AFCI BREAKER". KITCHENS, BATHROOMS AND BASEMENTS ARE EXEMPT FROM THIS REQUIREMENT. [CEC 210.12(A)] 40. AT LEAST ONE OUTSIDE WEATHERPROOF 120 VOLT RECEPTACLEOUTLET INSTALLED WITHIN THE PERIMETER OF THE BALCONY, DECKOR PORCH AND LOCATED NOT MORE THAN 6 1/2" FEET ABOVE THEFINISH SURFACE. EXCEPTION: AREAS LESS THE 20 SQUARE FEETARE NOT REQUIRED TO HAVE A RECEPTACLE INSTALLED.CEC 210.52(E) (3) 41. ALL 15- AND 20- AMPERE, 125- AND 250-VOLT NON-LOCKING RECEPTACLES THAT ARE INSTALLED ON THE EXTERIOR OF A DWELLING UNIT AND LOCATED IN DAMP OR WET LOCATIONS, SHALL BE LISTED AS WEATHER-RESISTANT TYPE. [CEC 406.9(A) & (B)] 42. ANY FIXED APPLIANCE SUCH AS DISPOSAL, DISHWASHER, CLOTHES WASHER, DRYER, BUILT-IN HEATER, OR ANY OTHER FIXED APPLIANCE WITH 1/4 H.P. MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH CIRCUIT. EACH DWELLING UNIT SHALL HAVE INSTALLED THEREIN AN INDIVIDUAL DISPOSAL CIRCUIT SUPPLIED WITH MINIMUM #12 AWG WIRE AND A 15 AMP INDICATING-TYPE SWITCH. [ CEC 210.23 & 220] 43. RECESSED LIGHTING INSTALLED IN AN INSULATED CEILING SHALL BE:A. LISTED AS AT/ICB. SEALED AND/OR CONTAIN A GASKETC. RECESSED FIXTURES INSTALLED IN A RATED CEILINGSHALL HAVE A SECONDARY RATED ASSEMBLY EQUALTO THE RATING PENETRATING. 44. OUTDOOR RECEPTACLES SHALL BE LISTED AS WEATHER RESISTANTPER SECTION 406.9(B)(1). 45. DOORS THAT PROVIDE DIRECT ACCESS TO THE SWIMMING POOL SHALL BE PROVIDED WITH AN APPROVED POOL ALARM OR APPROVED BARRIER PER CITY POOL ORDINANCE. 46. ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS,REPAIRS, OR ADDITIONS REQUIRING A PERMIT AND HAVING A VALUATION IN EXCESS OF $1,000, OR WHEN ONE OR MORE SLEEPINGROOMS ARE ADDED OR CREATED, THE ENTIRE DWELLING SHALLPROVIDED WITH DECTECTORS LOCATED AS REQUIRED FOR A NEWDWELLING. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWINGLOCATIONS: A. IN EACH SLEEPING ROOMB. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATEVICINITY OF THE BEDROOMSC. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDINGBASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDINGCRAWL SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS ORDWELLING UNITS WITH SPLIT LEVELS AND WITHOUT ANINTERVENING DOOR BETWEEN THE ADJACENT LEVELS, ASMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALLSUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THATTHE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOWTHE UPPER LEVELD. WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BEINSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARMDEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THATTHE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THEALARMS IN THE INDIVIDUAL UNIT. 47. ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS,REPAIRS, OR ADDITIONS REQUIRING A PERMIT AND HAVING AVALUATION IN EXCESS OF $1,000, AN APPROVED CARBON MONOXIDEALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPINGUNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED ANDIN DWELLING UNITS THAT HAVE ATTACHED GARAGES SHALL BEPROVIDED WITH A CARBON MONOXIDE ALARM IN ACCORDANCEWITH SECTION R315.1. A. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THESPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICHTHE PERMIT WAS OBTAINED. CARBON MONOXIDE ALARMSREQUIRED BE SECTION R315.1 AND R315.2 SHALL BE INSTALLEDIN THE FOLLOWING LOCATIONS:B. OUTSIDE OF EACH SEPARATE DWELLING UNIIT SLEEPING AREAIN THE IMMEDIATE VICINITY OF THE BEDROOM(S)C. ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTSD. WHERE MORE THAN ONE CARBON MONOXIDE ALARM ISREQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT ORWITHIN A SLEEPING UNIT THE ALARM SHALL BE INTERCONNECTEDIN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATEALL OF THE ALARMS IN THE INDIVIDUAL UNIT 48. CARBON MONOXIDE ALARMS COMBINED WITH SMOKE ALARMS SHALLCOMPLY WITH BOTH SECTIONS R314 AND SECTION R315, ALL APPLICABLESTANDARDS, AND REQUIREMENTS FOR LISTINGS AND APPROVAL BYTHE OFFICE OF THE STATE FIRE MARSHAL, FOR SMOKE ALARMS 49. UTILITY SERVICE TO BE UNDERGROUND WHEN THE PROPERTY ISDEVELOPED WITH A NEW OR RE-LOCATED MAIN BUILDING ORALTERATIONS EXCEED 50% OF VALUE AND/OR AREA OF THEEXISTING BUILDING UNIT "A" - MAIN LEVEL VENTILATION RATE (CFM) = 567 / 100 + 7.5 x 0+1) = cfm5.67 + 7.5 = 13.17 cfm PROVIDED: UNIT "A" - SECOND LEVEL VENTILATION RATE (CFM) = 590 / 100 + 7.5 x 2+1) = cfm5.90 + 22.5 = 28.40 cfm UNIT "A" - THIRD LEVEL VENTILATION RATE (CFM) = 262 / 100 + 7.5 x 1+1) = cfm2.62 + 15.0 = 17.62 cfm UNIT "B" - MAIN LEVEL VENTILATION RATE (CFM) = 580 / 100 + 7.5 x 1+1) = cfm5.80 + 15.0 = 20.80 cfm THEREFORE, PROVIDE (1) BROAN-NUTONE 30 CFM OR APPROVED EQUAL: 30 CFM @ .025" - 6" DIA. FLEXIBLE METAL DUCT WITHA MAXIMUM LENGTH OF 125' MINUS 15' FOR EACH ELBOW. PROVIDED: UNIT "B" - SECOND LEVEL VENTILATION RATE (CFM) = 290 / 100 + 7.5 x 1+1) = cfm2.90 + 15.0 = 17.90 cfm THEREFORE, PROVIDE (1) BROAN-NUTONE 30 CFM OR APPROVED EQUAL: 30 CFM @ .025" - 6" DIA. FLEXIBLE METAL DUCT WITHA MAXIMUM LENGTH OF 125' MINUS 15' FOR EACH ELBOW. Unit "A" BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10) w/cool roof: ASR: 0.23; TE: 0.82Roof attic: R-38 (2x4) cool roof: ASR: 0.23; TE: 0.82Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HERS MEASURESDucts leakage test - ducts in conditioned space (mandatory)Verified air flow (mandatory)Verified SEER (mandatory)Verified HSPF (mandatory)Verified heat pump rated heating capacity (mandatory)Fan watt draw (mandatory)IAQ Exhaust fan testing (mandatory)Kitchen range hood (mandatory)All pipes insulatedRefrigerant charge verificationQII HVAC - HEAT PUMPHeating: 10.5 HSPCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV3.0 Kw, southeast facing / 14" tiltBattery Storage: 5kWh; 95% charging/dischargingDeferred submittal, and under separate review and permit Unit "B" BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-38 (2x4)Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HERS MEASURESDucts leakage test - ducts in conditioned space (mandatory)Verified air flow (mandatory)Verified SEER (mandatory)Verified HSPF (mandatory)Verified heat pump rated heating capacity (mandatory)Fan watt draw (mandatory)IAQ Exhaust fan testing (mandatory)Kitchen range hood (mandatory)All pipes insulatedRefrigerant charge verificationQII HVAC - HEAT PUMPHeating: 9.5 HSPCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV3.0 Kw, southeast facing / 14" tiltBattery Storage: 5kWh; 95% charging/dischargingDeferred submittal, and under separate review and permit 50. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS SHALL BELOCATED NO MORE THAN 48" MEASURED FROM THE TOP OF THE OUTLETBOX AND NOT LESS THAN 15" MEASURED FROM THE BOTTOM OF THEOUTLET BOX ABOVE THE FINISH FLOOR. (CRC R327.1.2) 51. DOORBELL BUTTONS SHALL NOT BE INSTALLED MORE THAN 48" ABOVETHE EXTERIOR FLOOR OR LANDING. (CRC R327.1.4) 52. AUTOMATIC GARAGE DOOR OPENER INSTALLED IN A RESIDENCE MUSTHAVE AN AUTOMATIC REVERSE SAFETY DEVISE AND A BATTERY BACKUP FUNCTION THAT IS DESIGNED TO OPERATE WHEN ACTIVATED BECAUSEOF AN ELECTRICAL OUTAGE. AUTOMATIC GARAGE DOOR OPENER SHALLBE UL LISTED IN ACCORDANCE WITH UL 325. (CRC R309.4) 53. ALL HOSE BIBS SHALL BE FITTED WITH A NON-REMOVABLE BACK-FLOWDEVICE. (603.5.7) 54. THE MINIMUM EXHAUST RATE FOR THE KITCHEN RANGE SHALL FOLLOWTABLE 150.0-G. BEES 150(o), EXC. 5 TO 150.2(a), & ASHRAE STD. 62.2. TABLE 150.0-G HOOD OVERELECTRIC RANGE HOOD OVERNATURAL GAS RANGE DWELLING UNIT FLOOR AREA (ft) >1500 110 cfm 180 cfm >1000 - 1500 110 cfm 250 cfm 750 - 1000 130 cfm 280 cfm <750 160 cfm 280 cfm THEREFORE, PROVIDE (1) BROAN-NUTONE 20 CFM OR APPROVED EQUAL: 50 CFM @ .025" - 6" DIA. FLEXIBLE METAL DUCT WITHA MAXIMUM LENGTH OF 125' MINUS 15' FOR EACH ELBOW. THEREFORE, PROVIDE (1) BROAN-NUTONE 50 CFM OR APPROVED EQUAL: 50 CFM @ .025" - 6" DIA. FLEXIBLE METAL DUCT WITHA MAXIMUM LENGTH OF 125' MINUS 15' FOR EACH ELBOW. THEREFORE, PROVIDE (1) BROAN-NUTONE 30 CFM OR APPROVED EQUAL: 50 CFM @ .025" - 6" DIA. FLEXIBLE METAL DUCT WITHA MAXIMUM LENGTH OF 125' MINUS 15' FOR EACH ELBOW. 55. INDOOR LIGHTING CONTROL NOTES (CEnC SECTION 150.0(k)2) a. ADDS AUTO-OFF CONTROLS FOR LIGHTING IN DRAWERS AND CABINETS.b. UNDER-SHELF, DISPLAY CABINETS, SWITCHED OUTLETS CONTROLLEDSEPARATE FROM CEILING LIGHTING.c. LIGHTING IN HABITABLE SPACES SHALL HAVE ACCESSIBLE WALLMOUNTED DIMMING CONTROLS. 56. FOR NEW CONSTRUCTION, PROVIDE ENERGY STORAGE SYSTEMS READYSHALL MEET THE FOLLOWING: (CEnC SECTION 150.0(s))a. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED:i. ESS-READY INTERCONNECTION EQUIPMENT WITH A MINIMUMBACKED UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOURESS-SUPPLIED BRANCH CIRCUITS.ii. FOUR OR MORE BRANCH CIRCUITS FROM A SINGLE PANELBOARDSUITABLE TO BE SUPPLIED BY THE ESS: AT LEAST ONE CIRCUIT MUSTSUPPLY THE REFRIGERATOR, LIGHTING CIRCUIT NEAR THE PRIMARYEGRESS, AND A SLEEPING ROOM RECEPTACLE OUTLET.b. SUFFICIENT SPACE RESERVED TO ALLOW FUTURE INSTALLATION OF SYSTEMISOLATION EQUIPMENT OR A TRANSFER SWITCH WITHIN 3 FT. OF THE MAINPANELBOARD. 57. NEW CONSTRUCTION SHALL COMPLY WITH THE FOLLOWINGELECTRIC READINESS REQUIREMENTS (CEnC 150.0(t)-(v)): a. HEAT PUMP SPACE HEATER READY: IF A NATURAL GAS ORPROPANE FURNACE IS INSTALLED (CEnC 150.0(t)):i. INSTALL DEDICATED 240-VOLT, 30 AMP BRANCH CIRCUITWIRING WITHIN 3 FT. FROM THE FURNACE AND ACCESSIBLETO THE FURNACE WITH NO OBSTRUCTIONS.ii. RESERVE SPACE ON THE MAIN ELECTRICAL SERVICE PANELTO ALLOW FOR THE INSTALLATION OF A DOUBLE POLECIRCUIT BREAKERS FOR FUTURE FURNACE INSTALLATION. b. ELECTRIC COOKTOP READY: IF A GAS OR PROPANE COOKTOPSERVES INDIVIDUAL DWELLING UNITS, ADD THE FOLLOWING:(CEnC 150.0(u))i. INSTALL DEDICATED 240-VOLT, 50 AMP BRANCH CIRCUITWIRING WITHIN 3 FT. FROM THE COOKTOP ANDACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS.ii. RESERVE SPACE ON THE MAIN ELECTRICAL SERVICEPANEL TO ALLOW FOR THE INSTALLATION OF A DOUBLEPOLE CIRCUIT BREAKER FOR FUTURE COOKTOPINSTALLATION.c. ELECTRIC CLOTHES DRYER READY: IF A CLOTHES DRYERLOCATION HAS GAS OR PROPANE PLUMBING. ADD THEFOLLOWING (CEnC 150.0(v)) :i. INSTALL DEDICATED 240-VOLT 30 AMP BRANCH CIRCUITWIRING WITHIN 3 FT. FROM THE CLOTHES DRYER AND ACCESSIBLE TO THE CLOTHES DRYER WITH NOOBSTRUCTIONS.ii. RESERVE SPACE ON THE MAIN ELECTRICAL SERVICEPANEL TO ALLOW FOR THE INSTALLATION OF A DOUBLEPOLE CIRCUIT BREAKER FOR FUTURE CLOTHES DRYERINSTALLATION. TABLE 150.0-H >1500 < 50 >1000 - 1500 6 750 - 1000 7 < 25 6 6 < 200 7 8 < 250 8 8 < 75 7 7 < 350 9 9 Main Level Electrical Plan SCALE: 1/4" = 1'-0" 66 Master Suite Ba 2 Ma Bath Bed 2 Wic Ma Bedroom open to below Ma Bath Attic GFIWP LED HB GF I FL/WP FL/WP FL/WP SSSTV FG SSSSS SS V 3D 3D GFIWP SD CM SD CM A/C Disconnect Stair treadLights, connect tophotocell typ. Stair tread Lights, connect to photocell typ. FGConnect to Light above 3D LED Dryer outlet shall be 240V capable and GFI FG GF ISSSV S SS S S 3D Connect toFixtureAbove Connect to switch below Connectto Lightsbelow Stair treadLights, connect tophotocell typ. 3D 3D 3 D S TV SD CM SD CM SV SD CM TV S SSV SSSGFI V LED FG KEY Unit "A" Unit "B" S GFI S J-Boxfor Fan SS S D J-Boxfor Fan S D J-Boxfor Fan SSS3D 3D S D Outlet forBlinds D Outlet forBlinds LED Outlet forBlindsOutlet forBlinds T TS Master outdoorLighting Switch T CabinetBelow Outlet belowhandrail forChristmasLights GFI GF I Dryer Vent minimum4" dia. smooth, metal duct to outside air. GFI GFI Dryer outlet shall be 240V capableand GFI Dryer Vent minimum 4" dia. smooth, metalduct to outside airProvide Maker air grille above door with a min. of 100 Sq. In. of make up air (504.4.1 CMC) Provide Maker air grille above door with a min. of 100 Sq. In. of makeup air (504.4.1 CMC) IAQ Fan50 cfm IAQ Fan30 cfm Attic Access from below At Attic Provide:- 110 outlet - Light w/Switch Office Ba 3 Roof Deck A B Roof Deck HB WPGFI WPGFIFG KEY 3- One (1) GFI outlet4- One (1) Light fixture (with protective cover over bulb) with wall switch 5- One (1) Live land base Phoneline with pigtail (10'-0" min.)per code 1- Main Power: At Elevator Provide 10/3 with ground (min. 6") pigtail connection to house 30 Amp dedicated circuit2- Cab light Power:12/ 2 with ground (min. 6")pigtail connection to house 20 Amp dedicated circuit GFI S WPGFI SD CM SD CM PB LED FL/WP S LED LED TV GFI SSSV S S A/C Disconnect Connect toSwitch Below Stair treadLights, connect to photocell typ. Connect toPhotocell S S Connectto switchbelow A/C Disconnect 3D D WPGFI HB Stair treadLights, connect tophotocell typ. Unit "A" CoveredDeck LEDLED Connect to Photocell T CeilingOutlet LED WPGFI LED 3 3 WPGFILED WPGFI LED D FG WPGFI WPGFI WPGFI WPGFI Outlet forChristmaslights at eave Outlet for Christmaslights at eave Outlet forChristmaslights WPGFI Spa byothers Built-in Counter CeilingOutlet CeilingOutlet IAQ Fan50 cfm WPGFI At Attic Provide:- 110 outlet- Light w/Switch Second Level Electrical Plan SCALE: 1/4" = 1'-0" SECOND & THIRD LEVEL ELECTRICAL PLAN PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A6.2 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions ELECTRICAL LEGEND FL KEY F.G. HB SD PB CM POWERAPPLIANCE TV T S S3 S4 SD SV MINIMUM WHOLE BUILDING MECHANICAL VENTILATION(THE FOLLOWING INFORMATION AND CALCULATIONS ARE PER ASHRAE 62.2 RESIDENTIAL INDOOR AIR QUALITYAND MECHANICAL VENTILATION REPORT - REFER TO REPORT FOR MORE INFORMATION) CONTINUOUS VENTILATION CALCULATION: (MIN. AIRFLOW MEASURED @ 0.25" FOR CONTINUOUS OPERATION)(CFA / 100) + 7.5 (# OF BEDROOMS + 1) = VENTILATION RATE (MINIMUM CFM @ 0.25") CLG WHOLE BUILDING VENTILATION SYSTEM SUMMARY ALL LOW-RISE RESIDENTIAL BUILDING ARE REQUIRED TO HAVE A VENTILATION SYSTEM AND SATISFY OTHER REQUIREMENTSTO ACHIEVE ACCEPTABLE INDOOR AIR QUALITY (IAQ). THE ENERGY COMMISSION ADOPTED THE REQUIREMENTS OF ASHRAESTANDARD 62.2-2007, EXCEPT THAT OPENING AND CLOSING WINDOWS (ALTHOUGH PERMITTED BY ASHRAE) IS NOT ANACCEPTABLE OPTION FOR PROVIDING WHOLE-BUILDING VENTILATION IN CALIFORNIA. THE FOLLOWING BULLET POINTS SUMMARIZE THE KEY REQUIREMENTS FOR MOST RESIDENCE: 1. A WHOLE BUILDING MECHANICAL VENTILATION SYSTEM SHALL BE PROVIDED. 2. KITCHENS AND BATHROOMS SHALL HAVE LOCAL EXHAUST SYSTEMS VENTED TO THE OUTDOORS. 3. CLOTHES DRYERS SHALL BE VENTED TO THE OUTDOORS. 4. VENTILATION AIR SHALL COME FROM OUTDOORS AND SHALL NOT BE TRANSFERRED FROM THE ADJACENT DWELLING UNITS, GARAGES OR CRAWL SPACES. 5. VENTILATION SYSTEM CONTROLS SHALL BE LABELED AND THE HOME OWNER SHALL BE PROVIDED WITH INSTRUCTIONS ON HOW TO OPERATE THE SYSTEM. 6. COMBUSTION APPLIANCES SHALL BE PROPERLY VENTED AND AIR SYSTEMS SHALL BE DESIGNED TO PREVENT BACK DRAFTING. 7. THE WALL AND OPENINGS BETWEEN THE HOUSE AND THE GARAGE SHALL BE SEALED. 8. HABITABLE ROOMS SHALL HAVE WINDOWS WITH A VETILAION AREA OF AT LEAST 4% OF THE FLOOR AREA. 9. MECHANICAL SYSTEMS INCLUDING HEATING AND AIR CONDITIONING SYSTEMS THAT APPLY AIR TO HABITABLE SPACES SHALL HAVE MERV 6 FILTERS OR BETTER. 10. AIR INLET (NOT EXHAUST) SHALL BE LOCATED AWAY FROM KNOWN CONTAMINANTS. 11. AIR MOVING EQUIPMENT USED TO MEET EITHER THE WHOLE BUILDING VENTILATION REQUIREMENTS OR THE LOCAL VENTILATION EXHAUST REQUIREMENT SHALL BE RATED IN TERMS OF AIRFLOW AND SOUND: A. ALL CONTINUOUSLY OPERATING FANS SHALL BE RATED AT A MAXIMUM OF 1.0 SONE.B. INTERMITTENTLY OPERATED WHOLE BUILDING VENTILATION FANS SHALL BE RATED AT A MAXIMUM OF 1.0 SONE.C. INTERMITTENTLY OPERATED LOCAL EXHAUST FANS SHALL BE RATED AT A MAXIMUM OF 3.0 SONE.D. REMOTELY OPERATED AIR-MOVING EQUIPMENT (MOUNTED OUTSIDE OF HABITABLE SPACES) NEED TO MEET SOUND REQUIREMENTS IF THERE IS AT LEAST 4 FEET OF DUCTWORK BETWEEN THE FAN AND THE INTAKE GRILL. 12. A MINIMUM INTERMITTENT VENTILATION AIRFLOW OF 100 CFM IS REQUIRED FOR THE KITCHEN RANGE HOOD AND A MINIMUM INTERMITTENT VENTILATION AIRFLOW OF 50 CFM IS REQUIRED FOR THE BATH FAN. ELECTRICAL PLAN NOTES 9. KITCHEN COUNTER CIRCUITS SHALL BE DIVIDEDINTO TWO SEPARATE CIRCUITS. ALL SMALL APPLIANCE CIRCUIT SHALL BE ON A MIN. 20 AMP.CIRCUIT. REFRIGERATORS CANNOT BE ON EITHEROF THESE CIRCUITS, BUT MAY BE ON CIRCUITSWITH THE RANGE CLOCK AND/OR HOOD. 10. RECESSED FIXTURES - MUST BE RATED FORINSULATION CONTACT (IC-RATED), AIRTIGHT(ASTME283) AND SEALED W/ A GASKET OR CAULK BETWEEN HOUSE AND CEILING ALL HIGH-EFFICACYAND LOW-EFFICACY MUST BE CONTROLLEDSEPARATELY 11. GFI RECEPTACLES IN GARAGE OR AT PATIO SHALLNOT BE ON KITCHEN COUNTER CIRCUIT. 12. LIGHTS IN CLOTHES CLOSETS TO COMPLY ASFOLLOWS:A. CLOSET LESS THAN 70 SQ. FT. HAVE NOLIGHTING OR CONTROL REQUIREMENTS.B. CLOSET GREAT THAN 70 SQ. FT. EACHAND EVERY PERMANENTLY INSTALLEDLIGHTING FIXTURE MUST COMPLY WITHTHE STANDARDS, BY MEANS OF BEINGHIGH EFFICACY, CONTROLLED BY MANUAL-ON OCCUPANCY SENOR, ORCONTROLLED BY A DIMMER. 13. FIXTURES USED TO MEET FLUORESCENTREQUIREMENTS SHALL NOT CONTAINMEDIUM-BASED INCANDESCENT LAMP SOCKETS. 14. FIXTURES THAT WEIGH MORE THAN 6 POUNDS OREXCEED 16-INCHES IN ANY DIMENSION SHALL NOTBE SUPPORTED BY THE SCREW SHELL OF A LAMPHOLDER. 15. ALL BATHROOM FANS TO BE 50 CFM'S MINIMUM.PROVIDE A MINIMUM OF FIVE (5) AIR CHANGES PERHOUR. 16. SDG&E APPROVAL IS REQUIRED FOR METERLOCATION PRIOR TO INSTALLATION. 17. RECEPTACLES SHALL BE INSTALLED SO THAT NOPOINT ALONG THE FLOOR LINE IN ANY WALL SPACEIS MORE THAT 6 FEET, MEASURED HORIZONTALLY,FROM AN OUTLET IN THAT SPACE. RECEPTACLEOUTLETS SHALL, INSOFAR AS PRACTICABLE, BESPACED EQUAL DISTANCES APART. (C.B.C. 210-52) 18. MINIMUM OF (1) 20 AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM. CEC 210-11(C)(3). 1. ALL ELECTRICAL WORK SHALL BE INCONFORMANCE WITH LOCALLY ADOPTED BUILDING CODE AND ADMENDMENTS. ALLELECTRICAL WORK SHALL ALSO CONFORMWITH THE LOCAL BUILDING ENERGYEFFICIENCY STANDARDS. 2. PROVIDE SERVICE PANEL WITH U.F.E.R.GROUND AND BARE COPPER WIRE BONDED TOUNDERGROUND COLD WATER PIPE. 3. PROVIDE RECEPTACLE AND GAS SUPPLY TOFORCED AIR UNIT. PROVIDE A QUICKDISCONNECT AT ALL MECHANICALEQUIPTMENT AND A SERVICE RECEPTACLEWITHIN 25 FEET. 4. PROVIDE APPROVED CEILING MOUNTED SMOKEDETECTORS AS SHOWN ON PLAN WITHPERMANENT WIRING AND BATTERY BACK- UP,LOCATED A MIN. OF 3' IN FRONT OF THEKITCHEN SIDE OF THE RETURN AIR GRILL.PROVIDE AN ADDITIONAL DETECTOR NEAR THETOP OF A VAULTED OR HIGH CEILING, IF THEVAULT IS 24" HIGHER THAN THE HALLWAY TOTHE BEDROOMS. DETECTORS SHALL BEINSTALLED A MINIMUM OF 24" FROM ROOMREGISTERS AND SHALL BE INTERCONNECTED. 5. G.F.C.I. PROTECTION PER CEC 210.8(A) TO ALLALL 120 VOLTS, 15 AND 20 AMP RECEPTACLESINSTALLED IN THE FOLLOWING LOCTIONS:A. BATHROOMSB. GARAGES AND ACCESSORY BUILDINGSC. OUTDOORSD. CRAWL SPACESE. UNFINISHED BASEMENTSF. KITCHENS, WHERE THE RECEPTACLESARE INSTALLED TO SERVE THECOUNTERTOPSG. SINKS, LOCATED IN OTHER THANKITCHENS WHERE RECEPTACLES ARELOCATED WITHIN 6 FEET OF THEOUTSIDE EDGE OF THE SINK. (UTILITY,LAUNDRY, WET BARS, ETC.) 6. PROVIDE SEPARATE CIRCUITS FOR ALLANTICIPATED LOADS AS REQUIRED BY CODEGREATER THAN 20 AMPS. 7. KITCHEN GENERAL LIGHTING - HIGH EFFICACYOR UP TO 50% OF THE TOTAL WATTAGE CANBE LOW EFFICACY ALL HIGH-EFFICACY ANDLOW-EFFICACY MUST BE CONTROLLEDSEPARATELY 8. BATHROOMS - HIGH EFFICACY OR MANUAL-ONOCCUPANCY SENSOR 19. PROVIDE A MINIMUM OF 1-20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. CEC 210-11(C)(2) 20. PROVIDE A MINIMUM OF 2-20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN COUNTERTOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE BALANCED. CEC 210-11(C)(1) 21. FIELD INSPECTOR TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TOCONCRETE PLACEMENT. 22. ALL STAIRS SHALL HAVE AN ILLUMINATIONLEVEL ON TREADS RUNS OF NOT LESSTHAN 1 FOOT CANDLE (11 lux) CBC 1205.4 23. PROVIDE IN KITCHENS LOCAL EXHAUST SYSTEMVENTED TO OUTDOORS WITH RATE = 100 CFM. A MAXIMUM SOUND RATING OF 3 SONEFOR INTERMITTEN OPERATION IS REQUIRED 24. SMOKE DETECTORS ARE NOT TO BE LOCATED INKITCHEN, GARAGE, OR WITHIN 3 FEET FROMDOOR TO KITCHEN OR BATHROOM OR SUPPLY AIR REGISTERS 25. ALL DOORS FROM HOUSE TO POOL YARD MUST BEEQUIPPED WITH ALARM OR PROVIDE AN ALTERNATE DROWNING PREVENTION SAFETY FEATURE PER CBC 3109.4.4.2 26. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH AN EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 CFM. A MAXIMUM SOUND RATING OF 3 SONE FORINTERMITTEN OPERATION, BE LISTED AS ENERGYSTATE RATED AND CONTROLLED BY A HUMIDITYCONTROL UNLESS EXEMPTED ELSEWHEREDUCTLESS FANS ARE UNACCEPTABLE CBC 1203.4.2.1, CMC T-4-4. 27. FOR CFM OF EXHAUST FANS AND SONES LEVELSREFER TO MECHANICAL 28. ALL EXHAUST FANS SHALL BE CONTROLLED BY A HUMIDISTAT. 29. AIR MOVING EQUIPMENT MUST MEET REQUIREMENTS FOR SOUND OF 1 SONE FOR CONTINUOUS USE, OR 3 SONE FOR INTERMITTENT USE. 30. THE FOLLOWING SPECIFICATIONS FOR ELECTRICAL DEVICES INSTALLED IN DWELLINGS: CEC ARTICLE 210 & 406A) RECEPTACLES SHALL BE LISTED AS TAMPER-RESISTANT FOR ALL 15 AND 20 AMPERE RECEPTACLES IN DWELLING UNIT FAMILY, DINING, LIVING, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS AND AREAS PER CEC SECTION 406.12B) WEATHER RESISTANT TYPE FOR RECEPTACLES INSTALLED IN DAMP OR WET LOCATIONS. (OUTSIDE)C) ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION (AFCI) IS REQUIREC FOR ALL 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT FAMILY, DINING, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS AND AREAS PER CEC SECTION 210.12(A) 31. CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL TERMINATEOUTSIDE THE BUILDING AND HAVE A BACK-DRAFT DAMPER.EXHAUST DUCT IS LIMITED TO 14' WITH TWO ELBOWS. THISSHALL BE REDUCED 2' FOR EVERY ELBOW IN EXCESS OF TWOOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION(504.4 CMC) 32. SMOKE DETECTORS AND CARBON MONOXIDE ALARM INACCORDANCE WITH SECTION R315.1 SHALL BE INSTALLED ASFOLLOWS:A. WHERE MORE THAN SMOKE DETECTOR /CARBON MONOXIDE ALARM IS REQUIRED TO BEINSTALLED WITHIN THE DWELLING UNIT ORWITHIN A SLEEPING UNIT THE ALARM SHALL BEINTERCONNECTED IN A MANNER THATACTIVATION OF ONE ALARM SHALL ACTIVATEALL OF THE ALARMS IN THE INDIVIDUAL UNIT.B. SMOKE DETECTORS / CARBON MONOXIDEALARMS SHALL RECEIVE THEIR PRIMARYPOWER FROM THE BUILDING WIRING (HARDWIRED) AND SHALL BE EQUIPPED WITH ABATTERY BACK-UP. 33. LED LUMINAIRES MUST BE CERTIFIED AND QUALIFIED AS HIGH EFFICACY. 34. AT LEAST ONE HIGH EFFICACY LUMINAIRE IN EACH BATHROOM IS REQUIRED. SECTION 150.0(K) 35. HIGH EFFICACY LUMINARIES FOR RESIDENTIAL LIGHTING SHALLCONTAIN ONLY HIGH EFFICACY LAMPS SHALL NOT CONTAIN A MEDIUM SCREW BASE SOCKET (E24/E26). A HIGH EFFICACY LAMP HAS A LAMP EFFICACY THAT IS NO LOWER THAN EFFICACIES CONTAINED IN TABLE 150-C. BALLASTS FOR LAMPS RATED 13 WATTS OR GREATER SHALL BE ELECTRONIC AND SHALLHAVE AN OUTPUT FREQUENCY NO LESS THAN 20 kHz. 36. ALL HIGH EFFICACY LUMINARIES (INCLUDING RECESSED CAN FIXTURES) SHALL CONTAIN PIN BASED SOCKETS UNLESS ESPECIFICALLY APPROVED BY THE ENERGY COMMISION. [2008 EES 150(k) 1] 37. ALL NEW HVAC EQUIPMENT MUST HAVE AN EFFICIENCY RATING OF EER 13 [2008 EES 112] 38. ALL HEATING SYSTEMS SHALL HAVE AN AUTOMATIC THERMOSTAT WITH A CLOCK MECHANISM WHICH THE BUILDING OCCUPANT CAN MANUALLY PROGRAM TO AUTOMATICALLY SET BACK THE THERMOSTAT SET POINTS AT LEAST 4 PERIODS WITHIN 24 HOURS [2008 EES 150(i)] 39. ALL POWER AND LIGHTING OUTLETS IN FAMILY ROOM, PARLORS, LIBRARIES, DEN, BEDROOM, SUNROOMS, RECREATION ROOMS, HALLWAYS AND SIMILAR AREAS ARE TO BE PROTECTED BY A "LISTED AFCI BREAKER". KITCHENS, BATHROOMS AND BASEMENTS ARE EXEMPT FROM THIS REQUIREMENT. [CEC 210.12(A)] 40. AT LEAST ONE OUTSIDE WEATHERPROOF 120 VOLT RECEPTACLEOUTLET INSTALLED WITHIN THE PERIMETER OF THE BALCONY, DECKOR PORCH AND LOCATED NOT MORE THAN 6 1/2" FEET ABOVE THEFINISH SURFACE. EXCEPTION: AREAS LESS THE 20 SQUARE FEETARE NOT REQUIRED TO HAVE A RECEPTACLE INSTALLED.CEC 210.52(E) (3) 41. ALL 15- AND 20- AMPERE, 125- AND 250-VOLT NON-LOCKING RECEPTACLES THAT ARE INSTALLED ON THE EXTERIOR OF A DWELLING UNIT AND LOCATED IN DAMP OR WET LOCATIONS, SHALL BE LISTED AS WEATHER-RESISTANT TYPE. [CEC 406.9(A) & (B)] 42. ANY FIXED APPLIANCE SUCH AS DISPOSAL, DISHWASHER, CLOTHES WASHER, DRYER, BUILT-IN HEATER, OR ANY OTHER FIXED APPLIANCE WITH 1/4 H.P. MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH CIRCUIT. EACH DWELLING UNIT SHALL HAVE INSTALLED THEREIN AN INDIVIDUAL DISPOSAL CIRCUIT SUPPLIED WITH MINIMUM #12 AWG WIRE AND A 15 AMP INDICATING-TYPE SWITCH. [ CEC 210.23 & 220] 43. RECESSED LIGHTING INSTALLED IN AN INSULATED CEILING SHALL BE:A. LISTED AS AT/ICB. SEALED AND/OR CONTAIN A GASKETC. RECESSED FIXTURES INSTALLED IN A RATED CEILINGSHALL HAVE A SECONDARY RATED ASSEMBLY EQUALTO THE RATING PENETRATING. 44. OUTDOOR RECEPTACLES SHALL BE LISTED AS WEATHER RESISTANTPER SECTION 406.9(B)(1). 45. DOORS THAT PROVIDE DIRECT ACCESS TO THE SWIMMING POOL SHALL BE PROVIDED WITH AN APPROVED POOL ALARM OR APPROVED BARRIER PER CITY POOL ORDINANCE. 46. ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS,REPAIRS, OR ADDITIONS REQUIRING A PERMIT AND HAVING A VALUATION IN EXCESS OF $1,000, OR WHEN ONE OR MORE SLEEPINGROOMS ARE ADDED OR CREATED, THE ENTIRE DWELLING SHALLPROVIDED WITH DECTECTORS LOCATED AS REQUIRED FOR A NEWDWELLING. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWINGLOCATIONS: A. IN EACH SLEEPING ROOMB. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATEVICINITY OF THE BEDROOMSC. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDINGBASEMENTS AND HABITABLE ATTICS BUT NOT INCLUDINGCRAWL SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS ORDWELLING UNITS WITH SPLIT LEVELS AND WITHOUT ANINTERVENING DOOR BETWEEN THE ADJACENT LEVELS, ASMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALLSUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THATTHE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOWTHE UPPER LEVELD. WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BEINSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARMDEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THATTHE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THEALARMS IN THE INDIVIDUAL UNIT. 47. ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR ALTERATIONS,REPAIRS, OR ADDITIONS REQUIRING A PERMIT AND HAVING AVALUATION IN EXCESS OF $1,000, AN APPROVED CARBON MONOXIDEALARM SHALL BE INSTALLED IN DWELLING UNITS AND IN SLEEPINGUNITS WITHIN WHICH FUEL-BURNING APPLIANCES ARE INSTALLED ANDIN DWELLING UNITS THAT HAVE ATTACHED GARAGES SHALL BEPROVIDED WITH A CARBON MONOXIDE ALARM IN ACCORDANCEWITH SECTION R315.1. A. CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN THESPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICHTHE PERMIT WAS OBTAINED. CARBON MONOXIDE ALARMSREQUIRED BE SECTION R315.1 AND R315.2 SHALL BE INSTALLEDIN THE FOLLOWING LOCATIONS:B. OUTSIDE OF EACH SEPARATE DWELLING UNIIT SLEEPING AREAIN THE IMMEDIATE VICINITY OF THE BEDROOM(S)C. ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTSD. WHERE MORE THAN ONE CARBON MONOXIDE ALARM ISREQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT ORWITHIN A SLEEPING UNIT THE ALARM SHALL BE INTERCONNECTEDIN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATEALL OF THE ALARMS IN THE INDIVIDUAL UNIT 48. CARBON MONOXIDE ALARMS COMBINED WITH SMOKE ALARMS SHALLCOMPLY WITH BOTH SECTIONS R314 AND SECTION R315, ALL APPLICABLESTANDARDS, AND REQUIREMENTS FOR LISTINGS AND APPROVAL BYTHE OFFICE OF THE STATE FIRE MARSHAL, FOR SMOKE ALARMS 49. UTILITY SERVICE TO BE UNDERGROUND WHEN THE PROPERTY ISDEVELOPED WITH A NEW OR RE-LOCATED MAIN BUILDING ORALTERATIONS EXCEED 50% OF VALUE AND/OR AREA OF THEEXISTING BUILDING UNIT "A" - MAIN LEVEL VENTILATION RATE (CFM) = 567 / 100 + 7.5 x 0+1) = cfm5.67 + 7.5 = 13.17 cfm PROVIDED: UNIT "A" - SECOND LEVEL VENTILATION RATE (CFM) = 590 / 100 + 7.5 x 2+1) = cfm5.90 + 22.5 = 28.40 cfm UNIT "A" - THIRD LEVEL VENTILATION RATE (CFM) = 262 / 100 + 7.5 x 1+1) = cfm2.62 + 15.0 = 17.62 cfm UNIT "B" - MAIN LEVEL VENTILATION RATE (CFM) = 580 / 100 + 7.5 x 1+1) = cfm5.80 + 15.0 = 20.80 cfm THEREFORE, PROVIDE (1) BROAN-NUTONE 30 CFM OR APPROVED EQUAL: 30 CFM @ .025" - 6" DIA. FLEXIBLE METAL DUCT WITHA MAXIMUM LENGTH OF 125' MINUS 15' FOR EACH ELBOW. PROVIDED: UNIT "B" - SECOND LEVEL VENTILATION RATE (CFM) = 290 / 100 + 7.5 x 1+1) = cfm2.90 + 15.0 = 17.90 cfm THEREFORE, PROVIDE (1) BROAN-NUTONE 30 CFM OR APPROVED EQUAL: 30 CFM @ .025" - 6" DIA. FLEXIBLE METAL DUCT WITHA MAXIMUM LENGTH OF 125' MINUS 15' FOR EACH ELBOW. Unit "A" BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10) w/cool roof: ASR: 0.23; TE: 0.82Roof attic: R-38 (2x4) cool roof: ASR: 0.23; TE: 0.82Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HERS MEASURESDucts leakage test - ducts in conditioned space (mandatory)Verified air flow (mandatory)Verified SEER (mandatory)Verified HSPF (mandatory)Verified heat pump rated heating capacity (mandatory)Fan watt draw (mandatory)IAQ Exhaust fan testing (mandatory)Kitchen range hood (mandatory)All pipes insulatedRefrigerant charge verificationQII HVAC - HEAT PUMPHeating: 10.5 HSPCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV3.0 Kw, southeast facing / 14" tiltBattery Storage: 5kWh; 95% charging/dischargingDeferred submittal, and under separate review and permit Unit "B" BUILDING SHELLFixed windows: Dual pane/non-metal frame /0.34 U-factpr, 0.25 SHGCOperable windows: Dual pane/non-metal frame /0.35 U-factor, 0.25 SHGCFrench doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCPatio doors: Dual pane/non-metal frame /0.34 U-factor, 0.25 SHGCWalls: R-21 (2x6)Walls: R15 (2x4)No attic-Roof: R-30 (2x10)Roof attic: R-38 (2x4)Roof deck: R-30 (2x10) built-up roofingRaised floor: R-30 (2x10) HERS MEASURESDucts leakage test - ducts in conditioned space (mandatory)Verified air flow (mandatory)Verified SEER (mandatory)Verified HSPF (mandatory)Verified heat pump rated heating capacity (mandatory)Fan watt draw (mandatory)IAQ Exhaust fan testing (mandatory)Kitchen range hood (mandatory)All pipes insulatedRefrigerant charge verificationQII HVAC - HEAT PUMPHeating: 9.5 HSPCooling: 18 SEER, 11EERNew ductwork R-6 duct distribution in conditioned space WATER HEATERTankless94% energy efficiency99% recoveryAll pipes insulated PV3.0 Kw, southeast facing / 14" tiltBattery Storage: 5kWh; 95% charging/dischargingDeferred submittal, and under separate review and permit 50. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS SHALL BELOCATED NO MORE THAN 48" MEASURED FROM THE TOP OF THE OUTLETBOX AND NOT LESS THAN 15" MEASURED FROM THE BOTTOM OF THEOUTLET BOX ABOVE THE FINISH FLOOR. (CRC R327.1.2) 51. DOORBELL BUTTONS SHALL NOT BE INSTALLED MORE THAN 48" ABOVETHE EXTERIOR FLOOR OR LANDING. (CRC R327.1.4) 52. AUTOMATIC GARAGE DOOR OPENER INSTALLED IN A RESIDENCE MUSTHAVE AN AUTOMATIC REVERSE SAFETY DEVISE AND A BATTERY BACKUP FUNCTION THAT IS DESIGNED TO OPERATE WHEN ACTIVATED BECAUSEOF AN ELECTRICAL OUTAGE. AUTOMATIC GARAGE DOOR OPENER SHALLBE UL LISTED IN ACCORDANCE WITH UL 325. (CRC R309.4) 53. ALL HOSE BIBS SHALL BE FITTED WITH A NON-REMOVABLE BACK-FLOWDEVICE. (603.5.7) 54. THE MINIMUM EXHAUST RATE FOR THE KITCHEN RANGE SHALL FOLLOWTABLE 150.0-G. BEES 150(o), EXC. 5 TO 150.2(a), & ASHRAE STD. 62.2. TABLE 150.0-G HOOD OVERELECTRIC RANGE HOOD OVERNATURAL GAS RANGE DWELLING UNIT FLOOR AREA (ft) >1500 110 cfm 180 cfm >1000 - 1500 110 cfm 250 cfm 750 - 1000 130 cfm 280 cfm <750 160 cfm 280 cfm THEREFORE, PROVIDE (1) BROAN-NUTONE 20 CFM OR APPROVED EQUAL: 50 CFM @ .025" - 6" DIA. FLEXIBLE METAL DUCT WITHA MAXIMUM LENGTH OF 125' MINUS 15' FOR EACH ELBOW. THEREFORE, PROVIDE (1) BROAN-NUTONE 50 CFM OR APPROVED EQUAL: 50 CFM @ .025" - 6" DIA. FLEXIBLE METAL DUCT WITHA MAXIMUM LENGTH OF 125' MINUS 15' FOR EACH ELBOW. THEREFORE, PROVIDE (1) BROAN-NUTONE 30 CFM OR APPROVED EQUAL: 50 CFM @ .025" - 6" DIA. FLEXIBLE METAL DUCT WITHA MAXIMUM LENGTH OF 125' MINUS 15' FOR EACH ELBOW. 55. INDOOR LIGHTING CONTROL NOTES (CEnC SECTION 150.0(k)2) a. ADDS AUTO-OFF CONTROLS FOR LIGHTING IN DRAWERS AND CABINETS.b. UNDER-SHELF, DISPLAY CABINETS, SWITCHED OUTLETS CONTROLLEDSEPARATE FROM CEILING LIGHTING.c. LIGHTING IN HABITABLE SPACES SHALL HAVE ACCESSIBLE WALLMOUNTED DIMMING CONTROLS. 56. FOR NEW CONSTRUCTION, PROVIDE ENERGY STORAGE SYSTEMS READYSHALL MEET THE FOLLOWING: (CEnC SECTION 150.0(s))a. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED:i. ESS-READY INTERCONNECTION EQUIPMENT WITH A MINIMUMBACKED UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOURESS-SUPPLIED BRANCH CIRCUITS.ii. FOUR OR MORE BRANCH CIRCUITS FROM A SINGLE PANELBOARDSUITABLE TO BE SUPPLIED BY THE ESS: AT LEAST ONE CIRCUIT MUSTSUPPLY THE REFRIGERATOR, LIGHTING CIRCUIT NEAR THE PRIMARYEGRESS, AND A SLEEPING ROOM RECEPTACLE OUTLET.b. SUFFICIENT SPACE RESERVED TO ALLOW FUTURE INSTALLATION OF SYSTEMISOLATION EQUIPMENT OR A TRANSFER SWITCH WITHIN 3 FT. OF THE MAINPANELBOARD. 57. NEW CONSTRUCTION SHALL COMPLY WITH THE FOLLOWINGELECTRIC READINESS REQUIREMENTS (CEnC 150.0(t)-(v)): a. HEAT PUMP SPACE HEATER READY: IF A NATURAL GAS ORPROPANE FURNACE IS INSTALLED (CEnC 150.0(t)):i. INSTALL DEDICATED 240-VOLT, 30 AMP BRANCH CIRCUITWIRING WITHIN 3 FT. FROM THE FURNACE AND ACCESSIBLETO THE FURNACE WITH NO OBSTRUCTIONS.ii. RESERVE SPACE ON THE MAIN ELECTRICAL SERVICE PANELTO ALLOW FOR THE INSTALLATION OF A DOUBLE POLECIRCUIT BREAKERS FOR FUTURE FURNACE INSTALLATION. b. ELECTRIC COOKTOP READY: IF A GAS OR PROPANE COOKTOPSERVES INDIVIDUAL DWELLING UNITS, ADD THE FOLLOWING:(CEnC 150.0(u))i. INSTALL DEDICATED 240-VOLT, 50 AMP BRANCH CIRCUITWIRING WITHIN 3 FT. FROM THE COOKTOP ANDACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS.ii. RESERVE SPACE ON THE MAIN ELECTRICAL SERVICEPANEL TO ALLOW FOR THE INSTALLATION OF A DOUBLEPOLE CIRCUIT BREAKER FOR FUTURE COOKTOPINSTALLATION.c. ELECTRIC CLOTHES DRYER READY: IF A CLOTHES DRYERLOCATION HAS GAS OR PROPANE PLUMBING. ADD THEFOLLOWING (CEnC 150.0(v)) :i. INSTALL DEDICATED 240-VOLT 30 AMP BRANCH CIRCUITWIRING WITHIN 3 FT. FROM THE CLOTHES DRYER AND ACCESSIBLE TO THE CLOTHES DRYER WITH NOOBSTRUCTIONS.ii. RESERVE SPACE ON THE MAIN ELECTRICAL SERVICEPANEL TO ALLOW FOR THE INSTALLATION OF A DOUBLEPOLE CIRCUIT BREAKER FOR FUTURE CLOTHES DRYERINSTALLATION. TABLE 150.0-H >1500 < 50 >1000 - 1500 6 750 - 1000 7 < 25 6 6 < 200 7 8 < 250 8 8 < 75 7 7 < 350 9 9 Third Level Electrical Plan SCALE: 1/4" = 1'-0" 67 9 2x6 1 Dine Kitchen Pantry Entry Pdr Unit A Bath 4 Bedroom 3 Kitchen Unit B Family Deck Entry 9 9 9 9 9 9 3 9 9 8 9 9 9 9 8 8 8 8 8 8 8 8 9 9 8 9 8 1 1 1 1 1 1 Open to above 1 9 17 3 3 2x6 2x6 Unit B M Bedroom M Bath Unit B Bath 2Wic M BathMaster Suite Bedroom Unit A Open to below Attic 9 9 9 9 9 89 8 8 8 11 8 8 8 1 8 9 8 1 1 1 1 1 1 1 1 9 9 9 999999 9 99999 8 1 9 9 3 1 1 1 1 2x6 Office Bath 3 Hall Unit A 9 9 8 8 1 1 8 9 99 8 1 17 6 4 6 4 66 5 4 54 2x6 2x6 2x6 2x6 6 Beam Beam BeamRafter 1 2 15 15 2 Car Garage Carport 1 15 15 10 151616 1616 2 Main Level Reflected Ceiling Plan SCALE: 1/4" = 1'-0" REFLECTED CEILING PLANS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A8.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions REFLECTED CEILING PLAN KEY NOTES SYMBOLXX 1 DRYWALL CEILING 2 PLASTER FINISH CEILING 3 T&G SHEATHING 4 T&G ROOF SHEATHING 5 EXPOSED RAFTER TAIL 6 EXPOSED BEAMS AND RAFTERS 7 APPLIED WOOD BEAM 8 DOOR OPENING 9 WINDOW OPENING 10 GARAGE DOOR OPENING 11 FIREPLACE OPENING 12 DRYWALL OPENING 13 CASED OPENING 14 PLASTER OPENING 15 PLASTER SOFFIT 16 WOOD SOFFIT 17 ATTIC ACCESS Second Level Reflected Ceiling Plan SCALE: 1/4" = 1'-0"Third Level Reflected Ceiling Plan SCALE: 1/4" = 1'-0" Garage Level Reflected Ceiling Plan SCALE: 1/4" = 1'-0" 68 LOT 5 Pdr Dine Entry Unit "A" Kitchen Deck Ba 4 pantry Bed 3 Kit Family Unit "B" Total Main Level Living Unit "B" "A" = 580.16 sq.ft Total Main Level Living Unit "A" "A" = 596.05 sq.ft B Main Level Deck Unit "A" "D" = 98.5 sq.ft Main Level Deck - Unit "B" "D" = 35 sq.ft 5'-0" x 7'-0" D3 = 35 sq.ft 5'-8 1/2" x 15'-10" D1 = 90.38 sq.ft 15' - 1 0 " A 7'-0 " 5'-0" 11 ' - 1 0 " 10'-7"14'-11"4'-0"3'- 2 12" 7'- 0 12" 5'- 1 12" 5'-3" 1014" 5'-812" A 20'-4 1/2" x 18'-10" A1 = 383.73 sq.ft 18' - 1 0 " 18 ' - 0 34" 20'-412"3'-9" 3'-0 " 7'- 1 12" 8'-6" 4'-114" 5'-5 " 3'- 3 12" 10'-1" 3'-9" x 18'-0 3/4" A2 = 67.73 sq.ft 5'-2 1/2" x 3'-3 1/2" A3 = 17.12 sq.ft 5'-212" 10'-1" x 5'-5" A4 = 54.61 sq.ft 4'-1 1/4" x 3'-0" A5 = 12.31 sq.ft 8'-6" x 7'-1 1/2" A6 = 60.56 sq.ft 4'-0" x 3'-2 1/2" A12 = 12.83 sq.ft 18' - 1 0 " 18' - 6 " 5'-0" x 11'-10" A7 = 59.16 sq.ft 5'-0" 10'-7" x 18'-10" A8 = 199.31 sq.ft 10 1/4" x 7'-0 1/2" A11 = 6.01 sq.ft 5'-3" x 5'-1 1/2" A10 = 26.90 sq.ft 14'-11" x 18'-6" A9 = 275.95 sq.ft B 2'-812" 3'- 0 " 2'-8 1/2" x 3'-0" D2 = 8.12 sq.ft Crawl Space Garage 26'-0 1/2" x 3'-4 1/2" G1 = 70.63 sq.ft 21'-2" x 15'-6 1/2" G2 =328.97 sq.ft 5'-11 3/4" x 3'-0" G3 = 17.93 sq.ft 1'-7" x 7'-1 1/2" G4 = 11.28 sq.ft 3'- 4 12" 15' - 6 12" 21'-2" 5'-1134" 3'-0 " 1'-7" 26'-012" Total 2 Car Garage Area "G" = 443.90 sq.ft Total Carport Area "H" = 275 sq.ft 14'-7" x 18'-10" H1 = 275 sq.ft 14'-7" 18' - 1 0 " 7'-1 12" OVERLAY PLANS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A9.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR-OVERLAY O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R - O V E R L A Y A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions 2 Car Garage Level - Overlay Plan SCALE: 1/4" = 1'-0" Main Level - Overlay Plan SCALE: 1/4" = 1'-0" Allowable Floor Area: Allowable combined Exception : Sec 20.48.180.A.1.b.i Planning Criteria SETBACKS: 0'Front 5'2nd Front 3'Side Yard 1 MAXIMUM HEIGHT: 24'Flat Roof (less than 3:12 pitch)29'Pitched Roof (greater than 3:12 pitch) FAR: 2,009.77 Sq. Ft.Site Area MAXIMUM FLOOR AREA LIMIT: Buildable Area 2,876.66 Sq. Ft.Buildable Area 1,438.33 x 2 = 3'Side Yard 2 1,438.33 Sq. Ft. Development Standards R-2 Zone PARKING REQUIREMENTS: 2 Car off Street Parking Minimum Minimum Interior dimensions for Parkingspaces in residential zoning for a lot width30'-0" feet or less is 17'-6"x19'-0"(20.40) City of Newport Beach Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 596 Sq.Ft. 262 Sq.Ft.Third Level Living 1,448 Sq.Ft.Total Living Total Building Area 290 Sq.Ft. 870 Sq.Ft. Unit A Unit B 444 Sq.Ft. 880 Sq.Ft.1,176 Sq.Ft. 262 Sq.Ft. 2,318 Sq.Ft. 2,762 Sq.Ft. Total 69 Sq.Ft.Second Level Deck 69 Sq.Ft. Carport 275 Sq.Ft. THIRD FLOOR LIMITATIONS: Only subsection (A)(2)(c) applyFloor & Deck Area: 15' from Front & Rear Setback LinesLocation of Structure: 388 Sq.Ft.Roof Level Deck 494 Sq.Ft. 882 Sq.Ft. 556 Sq.Ft.Total Roof Deck 529 Sq.Ft. 1,085 Sq.Ft. 99 Sq.Ft.Main Level Deck 35 Sq.Ft. 134 Sq.Ft. 580 Sq.Ft. Hatching IndicatesGarage Area and Deck Area Hatching Indicates Living Area Hatching Legend Area OverlayTabulation 383.72 Sq. Ft.A1:67.73 Sq. Ft.A2: Total Main Level / Unit A 17.12 Sq. Ft.A3:54.61 Sq. Ft.A4:12.31 Sq. Ft.A5:60.56 Sq. Ft.A6: 596.05 Sq. Ft.Area: 103.28 Sq. Ft.B1: 93.37 Sq. Ft.B2: Total Second Level / Unit A 114.89 Sq. Ft.B3: 111.12 Sq. Ft.B4: 590.13 Sq. Ft.Area: 59.16 Sq. Ft.A7:199.31 Sq. Ft.A8: Total Main Level / Unit B 275.95 Sq. Ft.A9:26.90 Sq. Ft.A10:6.01 Sq. Ft.A11: 580.16 Sq. Ft.Area: 12.83 Sq. Ft.A12: 15.20 Sq. Ft.B6:10.10 Sq. Ft.B7: Total Second Level / Unit B 20.27 Sq. Ft.B8:142.50 Sq. Ft.B9:102.22 Sq. Ft.B10: 290.29 Sq. Ft.Area: 90.27 Sq. Ft.C1: 55.55 Sq. Ft.C2: Total Third Level / Unit A 96.33 Sq. Ft.C3: 19.89 Sq. Ft.C4: 262.04 Sq. Ft.Area: Total Main Level Deck / Unit A 90.38 Sq. Ft.D1: 98.5 Sq. Ft.Area: Total Second Level Deck / Unit A 69 Sq. Ft.E1: 69 Sq. Ft.Area: 308.31 Sq. Ft.F1: 11.37 Sq. Ft.F2: Total Roof Deck Level / Unit A 10.70 Sq. Ft.F3: 0.80 Sq. Ft.F4: 387.55 Sq. Ft.Area: 56.37 Sq. Ft.F5: 85.72 Sq. Ft.G1:328.97 Sq. Ft.G2: Total 2 Car Garage Level 17.93 Sq. Ft.G3: 11.28 Sq. Ft.G4: 443.90 Sq. Ft.Area: Carport 275 Sq. Ft.H1: 275 Sq. Ft.Area: 8.12 Sq. Ft.D2: Total Main Level Deck / Unit B 35 Sq. Ft.Area: 35 Sq. Ft.D3: B5: 167.47 Sq. Ft. 33.16 Sq. Ft.F6: 26.62 Sq. Ft.F7: Total Roof Deck Level / Unit B 87.27 Sq. Ft.F8: 17.62 Sq. Ft.F9: 494.23 Sq. Ft.Area: 92.22 Sq. Ft.F10:237.34 Sq. Ft.F11: 69 LOT 5 Master Suite Ba 2 Ma Bath Bed 2 Wic Ma Bedroom open to below Ma Bath Attic Unit "A" Unit "B" 3'-8"31'-412" 18 ' - 1 0 " 31'-112" 31'-1134" 31'-412" 3'-6 12" 3'-7 " 3'- 0 " 5'- 5 " 31'-4 1/2" x 3'-3 1/2" B1 = 103.28 sq.ft 31'-1 1/2" x 3'-0" B3 = 93.37 sq.ft 31'-11 3/4" x 3'-7" B4 = 114.89 sq.ft 31'-4 1/2" x 3'-6 1/2" B5 = 111.12 sq.ft 3'-8" x 18'-10" E = 69.04 sq.ft 4'-4 3/4" x 3'-5 1/2" B6 = 15.20 sq.ft 3'-1 3/4" x 3'-2 1/2" B7 = 10.10 sq.ft 6'-1" x 3'-4" B8 = 20.27 sq.ft 9'-4 3/4" x 15'-2" B9 = 142.50 sq.ft 6'-10" x 14'-11 1/2" B10 = 102.22 sq.ft 3'- 5 12"4'-434"9'-434"6'-10" 15 ' - 2 " 14' - 1 1 12" 6'-1"3'- 4 " 3'-134" 3'-2 12" Total Second Level Living Unit "B" "B" = 290 sq.ft B Total Second Level Living Unit "A" "B" = 590 sq.ft A Second Level Deck Unit "A" "E" = 69 sq.ft A 30'-11" x 5'-5" B2 = 167.47 sq.ft 3'-3 12" 30'-11" LOT 5 Office Ba 3 Roof Deck A B Roof Deck Unit "A" CoveredDeck Third level Deck/Stairs Unit "B" "F" = 494 sq.ftB 16'-1012" 16'-10 1/2" x 3'-3 1/2" C2 = 55.55 sq.ft 17'-1 1/2" x 5'-7 1/2" C3 = 96.33 sq.ft 10'-11 1/2" x 8'-5" F10 = 92.22 sq.ft 2'-6 3/4" x 6'-10 1/2" F9 = 17.69 sq.ft 17'-1 1/2" x 3'-3 1/2" F5 = 56.37 sq.ft 17'-11" x 17'-3 1/2" F1 = 308.31 sq.ft 16'-5 1/2" x 1'-2 1/2" C4 = 19.89 sq.ft 17'-9" x 1'-6" F7 = 26.62 sq.ft 16'-0" x 14'-10" F11 = 133.5 sq.ft 17'-9" 2'-634"10'-1112"16'-0" 4'- 1 1 " 8'- 5 " 14 ' - 1 0 " 6'- 1 0 12" Third level Deck Unit "A" "F" = 388 sq.ftA Total Third level Living Unit "A" "C" = 262 sq.ftA 16'-7 1/2" x 5'-5" C1 = 90.27 sq.ft 1'- 2 12" 5'- 7 12" 3'- 3 12" 5'-5 " 16'-512" 17'-112" 7'-0"6'-7" 1'- 7 12" 1'- 7 12" 1'- 2 12" 17 ' - 3 12" 6'-7" x 1'-7 1/2" F3 = 10.70 sq.ft 8" x 1'-2 1/2" F4 = 0.80 sq.ft 8" 7'-0" x 1'-7 1/2" F2 = 11.37 sq.ft 17'-11" 3'- 3 12" 1'- 6 " 1'-1 0 " 18'-212" 18'-2 1/2" x 1'-10" F6 = 33.16 sq.ft 17'-9" x 4'-11" F8 = 87.27 sq.ft 16'-712" 17'-112" Second Level - Overlay Plan SCALE: 1/4" = 1'-0" OVERLAY PLANS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A9.2 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR-OVERLAY O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R - O V E R L A Y A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions Allowable Floor Area: Allowable combined Exception : Sec 20.48.180.A.1.b.i Planning Criteria SETBACKS: 0'Front 5'2nd Front 3'Side Yard 1 MAXIMUM HEIGHT: 24'Flat Roof (less than 3:12 pitch)29'Pitched Roof (greater than 3:12 pitch) FAR: 2,009.77 Sq. Ft.Site Area MAXIMUM FLOOR AREA LIMIT: Buildable Area 2,876.66 Sq. Ft.Buildable Area 1,438.33 x 2 = 3'Side Yard 2 1,438.33 Sq. Ft. Development Standards R-2 Zone PARKING REQUIREMENTS: 2 Car off Street Parking Minimum Minimum Interior dimensions for Parkingspaces in residential zoning for a lot width30'-0" feet or less is 17'-6"x19'-0"(20.40) City of Newport Beach Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 596 Sq.Ft. 262 Sq.Ft.Third Level Living 1,448 Sq.Ft.Total Living Total Building Area 290 Sq.Ft. 870 Sq.Ft. Unit A Unit B 444 Sq.Ft. 880 Sq.Ft.1,176 Sq.Ft. 262 Sq.Ft. 2,318 Sq.Ft. 2,762 Sq.Ft. Total 69 Sq.Ft.Second Level Deck 69 Sq.Ft. Carport 275 Sq.Ft. THIRD FLOOR LIMITATIONS: Only subsection (A)(2)(c) applyFloor & Deck Area: 15' from Front & Rear Setback LinesLocation of Structure: 388 Sq.Ft.Roof Level Deck 494 Sq.Ft. 882 Sq.Ft. 556 Sq.Ft.Total Roof Deck 529 Sq.Ft. 1,085 Sq.Ft. 99 Sq.Ft.Main Level Deck 35 Sq.Ft. 134 Sq.Ft. 580 Sq.Ft. Third Level Roof Deck - Overlay Plan SCALE: 1/4" = 1'-0" Hatching IndicatesGarage Area and Deck Area Hatching Indicates Living Area Hatching Legend Area OverlayTabulation 383.72 Sq. Ft.A1:67.73 Sq. Ft.A2: Total Main Level / Unit A 17.12 Sq. Ft.A3:54.61 Sq. Ft.A4:12.31 Sq. Ft.A5:60.56 Sq. Ft.A6: 596.05 Sq. Ft.Area: 103.28 Sq. Ft.B1: 93.37 Sq. Ft.B2: Total Second Level / Unit A 114.89 Sq. Ft.B3: 111.12 Sq. Ft.B4: 590.13 Sq. Ft.Area: 59.16 Sq. Ft.A7:199.31 Sq. Ft.A8: Total Main Level / Unit B 275.95 Sq. Ft.A9:26.90 Sq. Ft.A10:6.01 Sq. Ft.A11: 580.16 Sq. Ft.Area: 12.83 Sq. Ft.A12: 15.20 Sq. Ft.B6:10.10 Sq. Ft.B7: Total Second Level / Unit B 20.27 Sq. Ft.B8:142.50 Sq. Ft.B9:102.22 Sq. Ft.B10: 290.29 Sq. Ft.Area: 90.27 Sq. Ft.C1: 55.55 Sq. Ft.C2: Total Third Level / Unit A 96.33 Sq. Ft.C3: 19.89 Sq. Ft.C4: 262.04 Sq. Ft.Area: Total Main Level Deck / Unit A 90.38 Sq. Ft.D1: 98.5 Sq. Ft.Area: Total Second Level Deck / Unit A 69 Sq. Ft.E1: 69 Sq. Ft.Area: 308.31 Sq. Ft.F1: 11.37 Sq. Ft.F2: Total Roof Deck Level / Unit A 10.70 Sq. Ft.F3: 0.80 Sq. Ft.F4: 387.55 Sq. Ft.Area: 56.37 Sq. Ft.F5: 85.72 Sq. Ft.G1:328.97 Sq. Ft.G2: Total 2 Car Garage Level 17.93 Sq. Ft.G3: 11.28 Sq. Ft.G4: 443.90 Sq. Ft.Area: Carport 275 Sq. Ft.H1: 275 Sq. Ft.Area: 8.12 Sq. Ft.D2: Total Main Level Deck / Unit B 35 Sq. Ft.Area: 35 Sq. Ft.D3: B5: 167.47 Sq. Ft. 33.16 Sq. Ft.F6: 26.62 Sq. Ft.F7: Total Roof Deck Level / Unit B 87.27 Sq. Ft.F8: 17.62 Sq. Ft.F9: 494.23 Sq. Ft.Area: 92.22 Sq. Ft.F10:237.34 Sq. Ft.F11: 70 VALLEY ROOF SHT'G SADDLE VARIES 21005-R-RAKEWALL-2B RAKE TO WALL SCALE: 1 1/2" = 1'-0" 21005-R-ROOFWALL-2B ROOF TO WALL SCALE: 1 1/2" = 1'-0" 1 2 3 4 515 24 30 27 26 9 10 717 ROOF DRAIN - PRIMARY AND OVERFLOW SCALE 3" = 1'-0" 3"3"8" MINIMUM5" MIN 5" MIN RADIANT BARRIER,REFER TO SHEETT-24.MM FOR INSTALLATION METHODS RIDGE / HIP EAVE SCALE 1-1/2" = 1'-0" 3 12 FELT UNDERLAYMENT PLYWOOD SHEATHING 5" DIA. HALF ROUNDCOPPER GUTTER ROOF FRAMING PER STRUCTURAL CORROSION RESISTANT FLASHING STANDING SEAM ROOFING - IN ACCORDANCE WITHMANUF. SPECS 2X FRAMING SEE PLAN AND STRUC. DWGS. 8" INTERIOR FINISH MATERIAL 2x NOMINALT&GSTARTER BOARD -DROP TO TOP FLUSHW/ SHEATHING FLAT CEILINGMAY OCCUR 1x VERTICAL WOOD SIDING OVER GRADE "D" BUILDING PAPER 3 x 5 TAILS SCABBED TO ROOFFRAMING EQUALLY SPACED(ACTUAL SIZE) GUARDRAIL WALL AT DECK SCALE 1-1/2" = 1'-0" FELT UNDERLAYMENT PLYWOOD SHEATHING ROOF DECK FRAMINGPER STRUCTURAL STANDING SEAM ROOFING -IN ACCORDANCE WITH MANUF. SPECS 2 x WALL CAP ELASTOMERIC SHEETWATERPROOFING 4"Min. 5" Min.8" Min.5" Min. OVERFLOW CLAMPING RING OVERFLOW DRAIN LEADER DEX-O-TEXWHEATHERWEARSYSTEMICC REPORT ESR-1757 DRAIN BOWL FIBER CANT STRIP TOMATCH HEIGHT OF SUMP OVERFLOW DRAIN 2" HIGHER THAN PRIMARY DRAIN 1x VERTICAL WOOD SIDING OVER GRADE "D" BUILDING PAPER PLYWOODSUBFLOOR DEX-O-TEX WATERPROOFMEMBRANE 26 GA SHEET METAL FLASHING G.I. SCREED FLASHING W/ WEEP HOLES 3 12 UNVENTED DECK SPRAY FOAM INSULATION AT DECK SHEATHING NOTE: USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYSAND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVESEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCH MINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOIST CAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREAD INDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. EAVE AT DECK FRAMING SCALE 1-1/2" = 1'-0" 3 12 FELT UNDERLAYMENT PLYWOOD SHEATHING 5" DIA. HALF ROUND COPPER GUTTER ROOF DECK FRAMINGPER STRUCTURAL CORROSIONRESISTANT FLASHING STANDING SEAM ROOFING - IN ACCORDANCE WITH MANUF. SPECS 2X FRAMING SEE PLAN AND STRUC. DWGS. 4" INTERIOR FINISHMATERIAL 2x NOMINALT&G STARTER BOARD - DROP TO TOP FLUSH W/ SHEATHING 1x VERTICAL WOODSIDING OVER GRADE "D"BUILDING PAPER 3 x 5 TAILS SCABBED TO ROOF FRAMING EQUALLY SPACED (ACTUAL SIZE HEAVY TIMBER) SOLID FIRE BLOCKING UNVENTED DECK SPRAY FOAM INSULATION AT DECK SHEATHING NOTE: USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYS AND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVESEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCHMINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOISTCAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREAD INDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. BUILT-UP ROOF SCALE 1-1/2" = 1'-0" CORROSION RESISTANT FLASHING SHEET METAL FINISH OVER 60 MIN. GRADE "D"BLDG. PAPER 2x4 WOOD TRIMCUT TO FIT SHEET METAL ROOFING SLOPED EPS DECK SYSTEM ICC ESR-1962 DECK SHEATHING UNDERLAYMENT ROOF FRAMING VERTICAL SIDING OVER 60 MIN. GRADE "D" BLDG. PAPER FULLY ADHERED WATERPROOFMEMBRANE 2x6 WOOD TRIM DRYWALL FINISH 2X WALL FRAMING 20 22012-R-RAKE-02 RAKE SCALE: 1 1/2" = 1'-0" 8" 2x NOMINALT&G STARTER BOARD -DROP TO TOP FLUSHW/ SHEATHING EAVE AT DECK FRAMING SCALE 1-1/2" = 1'-0" 3 12 FELT UNDERLAYMENT PLYWOOD SHEATHING ROOF DECK FRAMING PER STRUCTURAL CORROSIONRESISTANT FLASHING STANDING SEAM ROOFING -IN ACCORDANCE WITHMANUF. SPECS 2X FRAMING SEE PLANAND STRUC. DWGS. INTERIOR FINISH MATERIAL 2x WOOD TRIM 1x VERTICAL WOOD SIDING OVER GRADE "D" BUILDING PAPER SOLID FIRE BLOCKING UNVENTED DECK SPRAY FOAM INSULATION AT DECK OR ROOF SHEATHING NOTE: USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYSAND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVE SEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCH MINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOIST CAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREADINDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. ARCHITECTURAL DETAILS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: D-1.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-DETAILS O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - D E T A I L S A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions 71 1 2 3 4 5 12 13 14 15 18 19 2025 8 9 10 7 611 10" 3" MIN. VAPOR BARRIER AT WINDOWS SCALE 3" = 1'-0" PLYWOOD SHEATHINGWHERE OCCURS - SEESTRUCTURALDRAWINGS 12" FUTURE FLASH, 6"MIN. OVERLAP WALL FRAMING - SEE STRUCTURAL DWGS. JAMB BEYOND WINDOW FRAME NOTE:REFER TO DETAIL 25 / D2.1 FOR FLASHING AND BUILDING PAPER INSTALLATION REQUIREMENTS WINDOW HEAD SCALE 3" = 1'-0" SIDING OVER 60 MIN. GRADE 'D' BLDG. PAPER 2x2 WOOD TRIM 34" PLYWOOD SHEATHINGWHERE OCCURS - SEE STRUCTURAL DRAWINGS 12" FUTURE FLASH, 6" MIN. OVERLAP WALL FRAMING - SEE STRUCTURAL DWGS. SILL BEYOND WINDOW FRAME NOTE: REFER TO DETAIL 25 / D2.1 FOR FLASHING AND BUILDING PAPER INSTALLATION REQUIREMENTS WINDOW JAMB SCALE 3" = 1'-0" SIDING OVER 60 MIN. GRADE 'D' BLDG. PAPER 2x2 WOOD TRIM 34" 12" FUTURE FLASH, 6" MIN. OVERLAP WALL FRAMING - SEESTRUCTURAL DWGS. SILL BEYOND WINDOW FRAME NOTE:REFER TO DETAIL 25 / D2.1 FOR FLASHING ANDBUILDING PAPER INSTALLATION REQUIREMENTS WINDOW MULLION SCALE 3" = 1'-0" 1x WOOD TRIMOVER 60 MIN. GRADE 'D'BLDG. PAPER WINDOW FRAME SILL BEYOND NOTE:REFER TO DETAIL 25 / D-2.1 FOR FLASHING AND BUILDING PAPER INSTALLATION REQUIREMENTS WINDOW SILL SCALE 3" = 1'-0" PLYWOOD SHEATHINGWHERE OCCURS - SEESTRUCTURAL DRAWINGS 12" FUTURE FLASH, 6"MIN. OVERLAP WALL FRAMING - SEESTRUCTURAL DWGS. JAMB BEYOND WINDOW FRAME SIDING OVER 60 MIN. GRADE 'D' BLDG. PAPER 2x2 WOOD TRIM 34" CHIMNEY CAP SCALE 1-1/2" = 1'-0" 2" 2"4'-2"2" 5"1034"5" SIDE ELEVATION PLAN VIEW 112" 112" SECTION 378"1034"1034"378" 2"4'-6"2" 1.5" 1.5" 1.5" 1.5" 4"4'-2"4" 5"1034"378"1034"378"1034"5" 2"2'-912"2" 1.5" 1.5" 1.5" 1.5" 334"2'-2"334" 5"1'-4"5" FRONT/REAR ELEVATION 112" 2"2"112" 22012-EXT-TRIM-01 EXTERIOR WOOD TRIM SCALE: 1 1/2" = 1'-0" FLOOR SHEATHING 2X WOOD CAP SIDING FINISH OVER GRADE "D" BLDG. PAPER FLOOR FRAMING 12" 2x WOOD TRIM SIDING FINISH OVERGRADE "D" BLDG. PAPER 22012-EXT-WALL-BRK-01 EXTERIOR BREAKAWAY WALL SCALE: 1 1/2" = 1'-0" BREAKAWAYLOUVERED WALL FLOOR FRAMING 2x WOOD TRIM STUCCO OVER COR. RES.METAL LATH OVER 60 MIN. GRADE "D" BLDG PAPER G.I. SCREED 1x WOOD TRIM CONCRETE CURB ARCHITECTURAL DETAILS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: D-2.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-DETAILS O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - D E T A I L S A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions 72 VAPOR BARRIER AT DOORS SCALE 3" = 1'-0"08026-DR-FLSHG-VAPOR-01 3" MIN. 1 2 3 4 5 12 1520 29 30 8 9 10 7 611 17 16 GARAGE APRON SCALE: 3" = 1'-0" 14 DOOR THRESHOLD SCALE 3" = 1'-0" DOOR THRESHOLD SCALE 3" = 1'-0" 25 DOOR THRESHOLD SCALE 3" = 1'-0" PLYWOOD SHEATHING WHERE OCCURS - SEE STRUCTURAL DRAWINGS VAPOR BARRIER WALL FRAMING - SEE STRUCTURAL DWGS. SIDING OVER GRADE 'D' BUILDING PAPER NOTE:REFER TO DETAIL 29/D3.1 FOR FLASHINGAND BUILDING PAPER INSTALLATIONREQUIREMENTS DOOR FRAME DOOR HEAD SCALE 3" = 1'-0" 2x2 WOOD TRIM 34" PLYWOOD SHEATHING WHERE OCCURS - SEE STRUCTURAL DRAWINGS VAPOR BARRIER WALL FRAMING - SEE STRUCTURAL DWGS. SIDING OVER GRADE 'D' BUILDINGPAPER DOOR FRAME EXTERIOR PLASTER DOOR JAMB SCALE 3" = 1'-0" NOTE: REFER TO DETAIL 29/D3.1 FOR FLASHING AND BUILDING PAPER INSTALLATIONREQUIREMENTS 2x2 WOOD TRIM 34" DOOR THRESHOLD SCALE 3" = 1'-0" DOOR THRESHOLD SCALE 3" = 1'-0" PLYWOOD SHEATHING WHERE OCCURS - SEE STRUCTURALDRAWINGS VAPOR BARRIER WALL FRAMING - SEESTRUCTURAL DWGS. SIDING OVER GRADE 'D' BUILDING PAPER NOTE: REFER TO DETAIL 29/D3.1 FOR FLASHING AND BUILDING PAPER INSTALLATION REQUIREMENTS EDGE OF WALLBEYOND DOOR FRAME DOOR HEAD SCALE 3" = 1'-0" 2x2 WOOD TRIM PLYWOOD SHEATHING WHERE OCCURS - SEESTRUCTURALDRAWINGS VAPOR BARRIER WALL FRAMING - SEE STRUCTURAL DWGS. SIDING OVER GRADE'D' BUILDING PAPER NOTE: REFER TO DETAIL 29/D3.1 FOR FLASHING AND BUILDING PAPER INSTALLATION REQUIREMENTS DOOR FRAME 2x2 WOOD TRIM DOOR JAMB SCALE 3" = 1'-0" 34" PLYWOOD SHEATHING WHERE OCCURS - SEE STRUCTURALDRAWINGS VAPOR BARRIER WALL FRAMING - SEESTRUCTURAL DWGS. SIDING GRADE 'D' BUILDING PAPER NOTE: REFER TO DETAIL 29/D3.1 FOR FLASHING AND BUILDING PAPER INSTALLATION REQUIREMENTS EDGE OF WALL BEYOND DOOR FRAME DOOR HEAD SCALE 3" = 1'-0" 34" 2x2 WOOD TRIM PLYWOOD SHEATHING WHERE OCCURS - SEESTRUCTURALDRAWINGS VAPOR BARRIER WALL FRAMING - SEE STRUCTURAL DWGS. SIDING OVER GRADE'D' BUILDING PAPER NOTE: REFER TO DETAIL 29/D3.1 FOR FLASHING AND BUILDING PAPER INSTALLATION REQUIREMENTS DOOR FRAME 2x2 WOOD TRIM DOOR JAMB SCALE 3" = 1'-0" 34" FLOOR FRAMING ABOVE PLYWOOD SHEATHING SECTIONAL DOOR VINYL WEATHER STRIPPING SET IN WOOD BLOCK GARAGE DOOR HEAD SCALE: 3" = 1'-0" 2x FRAMING STUCCO OVER COR. RES. METAL LATH OVER 60 MIN. GRADE "D" BLDG PAPER 1'-0" GARAGE DOOR JAMB SCALE: 3" = 1'-0" STUCCO OVER COR. RES.METAL LATH OVER 60 MIN.GRADE "D" BLDG PAPER PLYWOOD SHEATHING WOOD FRAMING AT COLUMN BREAKAWAY LOUVEREDWALL BELOW SECTIONAL DOOR VINYL WEATHER STRIPPING SET INWOOD BLOCK BREAKAWAY LOUVEREDWALL BELOW KITCHEN ISLAND SINK VENT - VENT FIXTURE OUTLETPIPE (TAIL PIECE) CLEANOUT 2X WALL FRAMING FLOOR FRAMING ISLAND SINK DRAIN FOOT VENT HIGH WATER LINE VENT IF THE CODE-ALLOWABLE TAIL PIECE LENGTH DOES NOT PERMIT THE TRAP TO BE LOCATED BELOW THE FLOOR,A LOOP OR CIRCUIT VENT ARRANGEMENTWILL HAVE TO BE PROVIDED. ARCHITECTURAL DETAILS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: D-3.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-DETAILS O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - D E T A I L S A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions 73 1 2 3 4 5 14 15 23 24 25 29 28 27 26 22 8 9 10 7 6 STAIR AT LANDING SCALE 1-1/2" = 1'-0" RUN 10" MIN. 1" RUN 10" MIN. 1" STAIR AT LANDING SCALE 1-1/2" = 1'-0" STAIR GUARDRAIL SCALE 1-1/2" = 1'-0" 2" MAX 2" MAX STAIR HANDRAIL SCALE 1-1/2" = 1'-0" STAIR AT CONCRETE CAISSON SCALE 1-1/2" = 1'-0" 1" RUN 10" MIN. 1" 1" STAIR GUARDRAIL / HANDRAIL SCALE 1-1/2" = 1'-0" 1" STAIR AT LANDING SCALE 1-1/2" = 1'-0" RUN10" MIN. 1" 1" RUN10" MIN. 1" 1" STAIR AT LANDING SCALE 1-1/2" = 1'-0" RUN 10" MIN. 1 1/2"2" WALL HANDRAIL SCALE 1-1/2" = 1'-0" 1 1/2"2" WALL HANDRAIL SCALE 1-1/2" = 1'-0" 1x6 VERTICAL WOODSIDING OVER GRADE "D"BUILDING PAPER RUN 10" MIN. STAIR AT LANDING SCALE 1-1/2" = 1'-0" RUN10" MIN. 1" STAIR AT LANDING SCALE 1-1/2" = 1'-0" STAIR AT GUARDRAIL / HANDRAIL SCALE 1-1/2" = 1'-0" 1x WOOD SIDING OVER GRADE "D" BUILDING PAPER 2x WOOD CAP OVER ELASTOMERIC SHEET WATERPROOFING 2x WALL FRAMING STONE PAVER OVER MORTAR BED ELASTOMERICDECK COATING G.I. SCREED G.I. FLASHING 30 ARCHITECTURAL DETAILS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: D-4.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-DETAILS O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - D E T A I L S A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions 74 2 4 51520 24 2530 22 10 GUARDRAIL AT ROOF DECK FRAMING SCALE 1-1/2" = 1'-0" 3 12 FELT UNDERLAYMENT PLYWOOD SHEATHING 5" DIA. HALF ROUNDCOPPER GUTTER ROOF DECK FRAMINGPER STRUCTURAL CORROSION RESISTANT FLASHING STANDING SEAM ROOFING -IN ACCORDANCE WITHMANUF. SPECS 2X FRAMING SEE PLANAND STRUC. DWGS. 8" INTERIOR FINISHMATERIAL 2x NOMINALT&GSTARTER BOARD - DROP TO TOP FLUSH W/ SHEATHING 1x VERTICAL WOOD SIDING OVER GRADE "D"BUILDING PAPER 3 x 5 TAILS SCABBED TO ROOF FRAMING EQUALLY SPACED (ACTUAL SIZE HEAVY TIMBER) 2 x WALL CAP ELASTOMERIC SHEET WATERPROOFING ELASTOMERIC SHEETWATERPROOFING PLYWOOD SUBFLOOR DEX-O-TEXWATERPROOFMEMBRANE 26 GA SHEETMETAL FLASHING DEX-O-TEXWHEATHERWEARSYSTEM ICC REPORT ESR-1757 1x WOOD SIDING OVER GRADE "D" BUILDING PAPER DECK FRAMING STANDING SEAMMETAL ROOF WOOD SIDING TOP OF DECK SHEATHING ELEVATIONSECTION SOLID FIRE BLOCKING G.I. SCREED FLASHING W/WEEP HOLES 2 x WALL CAP NOTE: USE "HANDI FOAM" CLOSE CELL AT UNVENTED RAFTER BAYSAND DECK JOIST (TO BE INSTALLED BY A CERT. ICP ADHESIVESEALANTS INC.) R-30 INSULATION (6R VALUE PER INCH 5 INCHMINIMUM EQUALS R-30) FILL ALL RAFTER BAYS AND JOIST CAVITIES CAVITIES COMPLETELY TO MEET FLAME SPREAD INDEX REQUIRED. TYPICAL AT VOLUME CEILING AND DECK JOISTS. UNVENTED DECK SPRAY FOAM INSULATION AT DECK SHEATHING GUARDRAIL SCALE 1-1/2" = 1'-0" 2X WOOD CAP DECK FRAMINGPER STRUCTURAL 12" 2x WOOD TRIM PRIMARY DRAIN AND OVERFLOW ATINSIDE CORNERS OF DECK, REFER TO PLAN AND DETAIL 20/D-1.1 T&G WOOD SHEATHINGOVER BUILDING PAPER SLOPE FULLY ADHERED ELASTOMERIC DECK MEMBRANE, ICC ESR-2701 "LIFE DECK AL" G.I. SCREED FLASHING WITH WEEP HOLES G.I. FLASHING DECK SHEATHING OVERFLOWDRAINPRIMARYDRAIN SQUARE BASE SHOE L5"x5"x5/16" STEEL ANGLE WITH (4) #14x3" COUNTERSUNKWOOD SCREW FOUR IN TO ROWS 5/8" GLASS PANEL GUARDRAIL TEMPERED WITH EXPOSED EDGES POLISHED BY GRSGLASS BALUSTRADE GUARDSYSTEM OR APPROVED EQUALICC ESR-3842. INSTALLATION ON WOOD FRAMING SHALL FOLLOW FIGURE 4 OF THE ESR-3842 REPORT GUARDRAIL AT DECK SCALE 1-1/2" = 1'-0" ELEVATIONSECTION SQUARE BASE SHOE 2X WOOD CAP DECK FRAMING PER STRUCTURAL 12" 2x WOOD TRIM PRIMARY DRAIN AND OVERFLOW AT INSIDE CORNERS OF DECK, REFER TO PLAN AND DETAIL 20/D-1.1 SLOPE FULLY ADHERED ELASTOMERIC DECK MEMBRANE, ICC ESR-2701"LIFE DECK AL" G.I. SCREED FLASHING WITH WEEP HOLES G.I. FLASHING DECK SHEATHING WOOD WRAPPED COLUMN BEYOND EXT. PLASTER OVERCORROSION RESISTANTMETAL LATH OVER 60 MIN. GRADE "D" BLDG. PAPER 2x CORNER WOOD TRIM HORIZONTAL WOOD SIDING EXT. PLASTER OVERCORROSION RESISTANT METAL LATH OVER 60 MIN. GRADE "D" BLDG. PAPER OVERFLOWDRAIN PRIMARYDRAIN L5"x5"x5/16" STEEL ANGLE WITH (4) #14x3" COUNTERSUNK WOOD SCREW FOUR IN TO ROWS 5/8" GLASS PANEL GUARDRAILTEMPERED WITH EXPOSEDEDGES POLISHED BY GRSGLASS BALUSTRADE GUARD SYSTEM OR APPROVED EQUAL ICC ESR-3842. INSTALLATION ON WOOD FRAMING SHALL FOLLOWFIGURE 4 OF THE ESR-3842REPORT GUARDRAIL SCALE 1-1/2" = 1'-0" 5/8" GLASS PANEL GUARDRAILTEMPERED WITH EXPOSED EDGES POLISHED BY GRS GLASS BALUSTRADE GUARD SYSTEM OR APPROVED EQUALICC ESR-3842. INSTALLATION ONWOOD FRAMING SHALL FOLLOWFIGURE 4 OF THE ESR-3842 REPORT SQUARE BASE SHOE 2X WOOD CAP CONCRETE DECKPER STRUCTURAL 12" 2x WOOD TRIM PRIMARY DRAIN AND OVERFLOW AT INSIDE CORNERS OF DECK, REFER TO PLAN AND DETAIL 20/D-1.1 T&G WOOD SHEATHINGOVER BUILDING PAPER SLOPE FULLY ADHERED ELASTOMERICDECK MEMBRANE, ICC ESR-2701 "LIFE DECK AL" G.I. SCREED FLASHING WITH WEEP HOLES G.I. FLASHING OVERFLOWDRAINPRIMARYDRAIN L5"x5"x5/16" STEEL ANGLEWITH (4) #14x3" COUNTERSUNK WOOD SCREW FOUR IN TO ROWS ARCHITECTURAL DETAILS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: D-4.2 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-DETAILS O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - D E T A I L S A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions 75 76 MAP OF THIRD ADDITION TO NEWPORT BEACH BLOCK 39 M.M. 3/31 LOT 4 CL SE A S H O R E DR I V E CL ALLEY LOT 5 [B A S I S O F B E A R I N G S ] LOT 3 N52°46'30"E 79.33' N3 9 ° 5 3 ' 3 0 " W 2 5 . 0 3 ' 20.02' N3 9 ° 3 5 ' 3 0 " W 2 4 . 9 7 ' N52°46'30"E N52°46'30"E 54.46'N52°46'30"E 25.00' N3 9 ° 3 5 ' 3 0 " W 2 6 . 0 2 ' N39°35'30"W1.00' BASIS OF BEARINGS THE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OFSEASHORE DRIVE HAVING A BEARING OF N39°35'30"W PER RECORD OFSURVEY NO. 2016-1204, R.S.B. 290/47. VICINITY MAP BENCHMARK INFORMATION 39 0 7 S E A S H O R E D R I V E NE W P O R T B E A C H , C A 9 2 6 6 3 (A P N : 4 2 3 - 3 2 6 - 0 5 ) BO U N D A R Y & T O P O G R A P H I C M A P 1 1 TITLE REPORT/EASEMENT NOTES 3907 SEASHORE DRIVENEWPORT BEACH, CA 92663(APN: 423-326-05) NO TITLE REPORT PROVIDED LEGAL DESCRIPTION REAL PROPERTY SITUATED IN THE CITY OF NEWPORT BEACH,COUNTY OF ORANGE, STATE OF CALIFORNIA AND ISDESCRIBED AS FOLLOWS: LOT 4 AND THAT PORTION OF LOT 5 IN BLOCK 39, THIRD ADDITION TO NEWPORT BEACH, IN THE CITY OF NEWPORT BEACH, COUNTY OF ORANGE, STATE OF CALIFORNIA AS PER MAP RECORDED IN BOOK 3, PAGE 31, OF MISCELLANEOUS MAPS IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY, DESCRIBED AS FOLLOWS: COMMENCING AT THE MOST EASTERLY CORNER OF LOT 5,THENCE NORTHWESTERLY ALONG THE EXISTING PROPERTYLINE, 10 FEET; THENCE IN A SOUTHWESTERLY DIRECTION 25 FEET; THENCE IN A SOUTHEASTERLY DIRECTION, 1 FOOT; THENCE IN A NORTHEASTERLY DIRECTION, 25 FEET ALONG THE EXISTING PROPERTY LINES, TO THE POINT OF BEGINNING. LC EXISTING ELEVATION LEGEND ( ) AC ASPHALT PAVEMENT SEARCHED, FOUND NOTHING; SETNOTHING FS FL FINISHED SURFACE FLOWLINE FFG FINISHED FLOOR GARAGE CONCRETE SURFACE T.B.M.TEMPORARY BENCHMARKSET ON A LEAD & TAG STAMPED 'LS 5133' ELEVATION = 11.22 FEET NE W P O R T B E A C H , C A L I F O R N I A 9 2 6 6 0 PH O N E : ( 7 1 4 ) 4 8 8 - 5 0 0 6 A P E X L S I N C @ G M A I L . C O M PAUL D. CRAFT, P.L.S. 8516 DATE NOTE: SECTION 8770.6 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE STATES THAT THE USE OF THE WORD CERTIFY OR CERTIFICATION BY A LICENSED LAND SURVEYOR IN THE PRACTICE OF LAND SURVEYING OR THE PREPARATION OF MAPS, PLATS, REPORTS, DESCRIPTIONS OR OTHER SURVEYING DOCUMENTS ONLY CONSTITUTES AN EXPRESSION OF PROFESSIONAL OPINION REGARDING THOSE FACTS OR FINDINGS WHICH ARE THE SUBJECT OF THE CERTIFICATION AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE,EITHER EXPRESSED OR IMPLIED. LICENSE RENEWAL DATE 12/31/24 STATEOFCALIFORNIA PAUL DOMINICK CRAFTExp. 12/31/24No. 8516PROFESSIONALLANDSURVEYOR FF FINISHED FLOOR WATER VALVEWV EG EDGE OF GUTTER GAS METERGM CENTERLINE TC TOP OF CURB GRAPHIC SCALE BLOCK WALL NG NATURAL GROUND BENCHMARK NO: NB2-7-77 DESCRIBED BY OCS 2002 FOUND 3 3\4" OCS ALUMINUM BENCHMARK DISK STAMPED "NB2-7-77", SET IN THE SOUTHWEST CORNER OF A 7 FT. BY 4.5 FT. CONCRETE CATCH BASIN. MONUMENT IS LOCATED IN THE SOUTHEAST CORNER OF THEINTERSECTION OF SUPERIOR AVENUE AND PACIFICCOAST HIGHWAY, 400 FT. EASTERLY OF THECENTERLINE OF SUPERIOR AVENUE AND 48 FT. SOUTHERLY OF THE CENTER MEDIAN ALONG PCH. MONUMENT IS SET LEVEL WITH THE SIDEWALK. ELEVATION: 8.565 FEET (NAVD88), YEAR LEVELED 2015 FOUND MONUMENT AS NOTEDHEREON TB TOP OF BENCH WOOD FENCE (WDF) EPB ELECTRICAL PULL BOX WATER METERWM - LEAD AND TAG STAMPED 'LS 5133' TVLT SCO SEWER CLEANOUT MONUMENT NOTES - LEAD AND TAG STAMPED 'LS 6902' TELEPHONE VAULT TF TOP OF FENCE TS TOP OF STEP TW TOP OF WALL OWNER INFORMATION OWNER: KEN AND STEPHANIE BARNARD PHONE NUMBER: (949) 456-2300 & (949) 235-9416 ADDRESS: 3907 SEASHORE DRIVE, NEWPORT BEACH, CA 92663 1/26/2024 77 78 79 80 81 82 83 RATED WALL DETAILS PLOT REFERENCE DATE: 08-14-24 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: D-5.1 SHEET TITLE: ‹RITNER GROUP, INC. 2024 expressly reserves allcommon law copyright and property rights in these plans.These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent ofRITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-DETAILS-RATED O:\ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - D E T A I L S - R A T E D A u g u s t 1 4 , 2 0 2 4 BG RR 22012 Lot 4, Block 39 Bld g . D e p t . C o r r e c t i o n s 0 8 - 1 4 - 2 4 D e l t a 2 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: 1 03-21-24 Bldg. Dept. Corrections and Client Revisions 2 08-14-24 Bldg. Dept. Corrections and Client Revisions 84