Mechanical Permit
unim nwnnniwmm�uununiunnniunnnn Plan Check No :
Work Class : Other
Permit Status: Issued
Issued Date : 08/01/2024
Inspection Area : 6
H2O24-0466
PERMITS EXPIRE 180 DAYS AFTER ISSUANCE OR LAST VALID INSPECTION, BUT NO LATER THAN 3 YEARS FROM ORIGINAL ISSUANCE DATE
NO CONSTRUCTION RELATED NOISE ON SATURDAY OR SUNDAY IN HIGH DENSITY AREAS AND NO WORK ON SUNDAY AND HOLIDAYS IN ALL AREAS
Job Address: 7 ALMANZORA Legal Desc : N TR 15467 BILK LOT 33
Description: MECH - INSTL AC CONDENSERS (2) & FAU'S. TAMPER RESISTANT CAP REQUIRED
Owner: JEFFREY PO
Address : 7 ALMANZORA NEWPORT COAST, CA 92657
Phone : (949) 648-2738
Applicant: PUREAIR
Address: 12700 PIN EHURST CT GARDEN GROVE, CA 92840
Phone : (714) 537-9751
Owner/Builder :
Address
Phone:
Code Edition : 2022
Type of Construction
Occupancy Groups:
Building Setbacks
Flood Zone
Use Zone :
PROCESSED BY:
X
PC - Newport Coast
SPECIAL CONDITIONS:
Fire Hazard Zone : YES
Contractor : PURE AIR
Address :
12700 PINEHURST CT GARDEN GROVE, CA 92840
Phone:
(714) 537-9751
Con State Lic
: 792214
Lic Expire:
03/31/2025
Bus Lic:
BT30084878
Bus Lic Expire: 0713112025
Workers' Compensation Insurance
Carrier :
WESCO INS.
Policy No:
TWC4242743
W. C. Expire:
2/22/2025
� .-ate. c^q
Manufacturer: TRANE
Model#: 4TTVOX60A/4TTVOX36B
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the reasons) indicated below by the checkmark(s) I have placed next to the applicable item(s)
(Section 7031.5. Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to Its issuance, also requires the applicant for
the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of
not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will do (_) all of or L) portions of the work, and the structure is not intended or offered for sale (Section 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or
improved for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' State License Law does not
1a�p-lply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State License Law).
ff I am exempt from licensure under the Contractors' State License Law for the following reason: _
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally
sell a structure that 1 have built as an owner -builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Business and
Professions Code, is available upon request when this application is submitted or at the following Web sfte:http:llwww.leginfo.ca.govlcelaw.htmi.
Signature of Property Owner or Authorized Agent Date
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70010)lof Div i ion 3 of the Business and Professions C dq 7Cy�my license is in full force
and effect. License Class License No Date 0 Contractor Signature ffLL�l LL
WORKERS' COMPENSATION DECLARATION
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS IS100.0001, IN ADDITION TO THE
COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY-S FEES.
if
I �hhereby affirm under penalty of perjury one of the following declarations:
11 have and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for th
6pe ormance of the work for which this permit is issued. Policy No.
I have and will maintain workers compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensatiol
insurance carrier and policy number are:
Policy Number
Date
ne of Agent rr1Ore R
certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agre
. if I should become subject(ty�F�ye" rkersI compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. p, �( /
3ature of Applicant \l IY I t / _ Dale_._ 0 V � �L L
CLARATION REGARDING CONSTRUCTION LENDING AGENCY
reby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Section 3097, Civil Code).
Idlers Name Lenders Address
my signature below, I certify to each of the following:
I am the property owner or authorized to act on the property owners behalf.
I have read this application and the information I have provided is correct.
I agree to comply with all applicable city and county ordinances and state laws relating to building construction.
I authorize representatives of this city or county to enter the above -identified property for inspection purposes. jj
nature of Prooertv Owner or Authorized Agent T , Print Property Owner's or Authorized Agent's Name -� V s N
ACTION DATE BY DECLARATION OF COMPLIANCE WITH CODE OF FEDERAL FOR OFFICE USE ONLY
REGULATIONS PART 61 OF TITLE 40 AND AQI RULE
1403
PERMIT EXPIRED I SUBMITTED ASBESTOS NOTIFICATION TO
PERMIT 17ANCEILEO OEPA
PERMIT FINA!. ASBESTO5 NOTIFICATION 15 NOT APPLICABLE TO
CERTIFICATEOF jOq/3Q/29 DVo� CS PROPOSED DEMOLITION
OCCUPANCY 155UED j SIGNATURE:
ALTERATIONS TO SPACE CONDITIONING SYSTEMS CFIR-ALT-02-E
CALIFORNIA ENERGY COMMISSION (FORMERLY CF-3R-ALT-HVAC)
(Page 1 of 3)
CERTIFICATE OF COMPLIANCE
Project Name:
almanzora
Enforcement Agency: Newport Beach, City of
Dwelling Address:
7 Almanzora
Permit Number:
City and Zip Code
Newport Beach, 92657
Permit Application Date: 2024-07-30
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit.
OIL
Project Name
almanzora
02
Date Prepared
2024-07-30
03
Project Location
7Almanzora
04
Building Type
Single family
05
CA City
Newport Beach
06
Dwelling Unit Name
almanzora
07
Zip Code
92657
08
Dwelling Unit Conditioned Floor
4251
Area (ftz)
Number of Space Conditioning
09
Climate Zone
6
30
(SC) Systems in this Dwelling
2
Unit:
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
SCS stem ID or
Y
SCS stem
Y
Location Area
CFA served b this
Y
Is the SC system a
Installinga
refrigerant
Installing new SC
Installing more
Installingentire)
y
Installingentire)
Y
Name
or
Served
SC System (ftz)
ducted system?
containing
system
than 25 feet of
new duct system?
new SC system?
Alteration Type
Yp
component?
components?
ducts?
Altered space
System 1
Location 1
2125
Yes
Yes
Yes
No
No
No
conditioning
System
Altered space
System 2
Location 2
2126
Yes
Yes
Yes
No
No
No
conditioning
system
Registration Number: 424-AO2014848OA-000-000-0000000-0000 Registration Date/Time: 2024-07-30 14:59:34 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using Information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards- 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2024-07-30 15:00:15
Schema Version: rev 20220101
ALTERATIONS TO SPACE CONDITIONING SYSTEMS CF1R-ALT-02-E
CALIFORNIA ENERGY COMMISSION (FORMERLY CF-IR-ALT-HVAC)
(Page 2 of 3)
C. Extension of Existing Duct System, Greater Than 25 Feet (Section150.2(b)1Dlib)
This section does not apply to this project.
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
010
11
12
13
14
Cooling
Cooling
Minimum
SC System
Altered
Heating
Altered
Minimum
Efficiency
Description
Heating
Heating
Heating
Minimum
Cooling
Cooling
Cooling
Efficiency
Value
Required
New or
System ID/
of Area
System
Component
Efficiency
Efficiency
System
Component
Efficiency
Value
EER/EER2/C
Thermostat
Replaced
New Duct
Name
Served
Type
s
Type
Value
Type
s
Type
SEER/SEER2
EER
Type
Duct Length
R-Value
No Heating
Central split
All new
N/A - no
System 1
Location 1
No Heating
Component
n/a
cooling
EERSEER
14
11.7
Setback
ducts
n/a
Altered
AC
components
replaced.
No Heating
Central split
All new
N/A- no
System 2
Location 2
No Heating
Component
n/a
cooling
EERSEER
14
11.7
Setback
ducts
n/a
Altered
AC
components
replaced.
Required Documentation
CF2R-MCH-01-E - Space Conditioning Systems
-Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 3, 5-7) and R8 (CZ 1, 2, 4, 8-16)
CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more
than 25 ft of duct length is replaced
-Leakage rate compliance: less than or equal to 10%or less than or equal to 7% leakage to outside, or seal all accessible leaks.
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate greater than or equal to 300 CFM per ton required when MCH-25 is required.
Exceptions:
- Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
- Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)lE, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number:424-A02014848OA-000-000-0000000-0000 Registration Date/Time: 2024-07-30 14:59:34 HERS Provider: CHEERS
NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using Inhumab'on uploaded by third parties not affi iated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, the accuracy or completeness of the information contained In this document.
CA Building Energy Efficiency Standards- 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2024-07-30 15:00:15
Schema Version: rev 20220101
ALTERATIONS TO SPACE CONDITIONING SYSTEMS
CALIFORNIA ENERGY COMMISSION (FORMERLY CF-IR-ALT-HVAC)
CFIR-ALT-02-E
(Page 3 of 3)
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certifythat this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Thanh Nguyen
T .-7_ N ety
Company:
Signature Date:
Pur Air
2024-07-30
Address:
CEA/ HERS Certification Identification (if applicable):
12700 Pinehurst Ct
City/State/Zip:
Phone:
Garden Grove CA 92840
714-537-9751
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of
Compliance (responsible designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this
Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable
compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
S. I understand that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to
the enforcement agency for all applicable inspections, and I will take the necessary steps to accomplish this requirement.
6. 1 understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at
occupancy, and I will take the necessary steps to accomplish these requirements.
Responsible Designer Name:
Responsible Designer Signature:
Thanh Nguyen
I.Y v
Tl -_ 7_ N �7
Company:
Date Signed:
Pur Air
2024-07-30
Address:
License:
12700 Pinehurst Ct
792214
City/State/Zip:
Phone:
Garden Grove CA 92840
714-537-9751
Digitally signed by California Home Energy Eficlency Rating Services (CHEERS). This digital signature is provided in order ro secure the content of
this registered document, and in no way implies Registration Pmvitler responsibility for the accuracy of the information.
Registration Number: 424-A020148480A-000-000-0000000-0000 Registration Date/Time: 2024-07-30 14:59:34 HERS Provider: CHEERS
NDRCE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for,
and cannot guarantee, Me accuracy or completeness of the information contained in this document.
CA Building Energy Efficiency Standards- 2022 Residential Compliance Report Version: 2022.0.000 Report Generated: 2024-07-30 15:00:15
Schema Version: rev 20220101