HomeMy WebLinkAbout4533Perham_CoastalSub#2_8-8-18LC
CL
LOT 117
LOT 115
EXISTING BUILDINGSITE PLAN
OWNER
ARCHITECT
CODES
AREAS:
TEALE ARCHITECTURE
2900 BRISTOL ST., BLDG A, SUITE 203
COSTA MESA, CA 92626
TEL: (949) 975-0123 FAX: (949) 274-4833
EMAIL: mteale@tealearchitecture.com
MARK TEALE . ARCHITECT C-22162
THE MOINFAR REVOCABLE LIVING TRUST
4501 TREMONT LANE
CORONA DEL MAR, CA 92625
TEL: (949) 975-0123
ALL WORK AND MATERIALS SHALL CONFORM STRICTLY TO THE 2013 C.R.C.; 2013 C.B.C.;
2013 C.P.C.; 2013 C.E.C.; 2013 C.M.C.; 2013 CEES (CA ENERGY); 2013 C.G. (CAL GREEN);
CHAPTER 15 OF THE NEWPORT BEACH MUNICIPAL CODE (NBMC); AND ALL OTHER FEDERAL,
STATE AND LOCAL CODE.
LEGAL DESCRIPTION: TRACT: 3357 LOT: 116
APN#475-013-06
ZONE R-1-6000
OCCUPANCY GROUP R-3/U (GARAGE)
CONSTRUCTION TYPE TYPE VB, SPRINKLERED
PARKING THREE CAR GARAGE
BASEMENT FLOOR 3,295 S.F.
FIRST FLOOR 5,007 S.F.
GARAGE 3,024 S.F.
DECK AND BALCONY 1,086 S.F.
TOTAL HABITABLE AREA 8,302 S.F.
TOTAL DECK AREA 1,086 S.F.
TOTAL GARAGE AREA 3,024 S.F.
TOTAL HABITABLE AREA + GARAGE 11,326 S.F.
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
..
.
.
PL
A
N
C
H
E
C
K
#
1
1
2
8
-
2
0
1
8
DEFERRED SUBMITTALS
DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT
AND/OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR
PLAN CHECK OR APPROVAL BY THE CITY.
SEE STRUCTURAL ENGINEERING DRAWINGS AND ENGRG DRAWINGS FOR
DEFERRED SUBMITTALS. VERIFY WITH STRUCTURAL ENGINEER.
-AUTOMATIC FIRE SPRINKLERS IN ACCORDANCE WITH NFPA 13D
-SEE STRUCTURAL DRAWINGS FOR STRUCTURAL DEFERRED
SUMBITTALS.
-STRUCTURAL STEEL SHOP DRAWINGS
-HVAC SOUND ATTENUATION DESIGN
SEE STRUCTURAL AND SHORING DRAWINGS FOR SPECIAL
INSPECTIONS.
VERIFY WITH STRUCTURAL PLANS.
-STEEL, SHOTCRETE, MASONRY GROUT (WHERE REQUIRED),
EXPANSION ANCHOR, ADHESIVE ANCHOR.
-STRUCTURAL STEEL WELDING AND HIGH STRENGTH BOLTING
SPECIAL INSPECTIONS
HEIGHT CERTIFICATION
NOTE TO GENERAL CONTRACTOR:
HEIGHT CERTIFICATION INSPECTION IS REQUIRED
REVISION HISTORY
4/28/17
1/8" - 1'-0"
SI
T
E
P
L
A
N
PR
O
J
E
C
T
D
A
T
A
SCALE:
START DATE:
SHEET
SH
E
E
T
PR
O
J
E
C
T
2
9
0
0
B
r
i
s
t
o
l
S
t
r
e
e
t
B
u
i
l
d
i
n
g
A
,
S
u
i
t
e
2
0
3
C o
s
t
a
M
e
s
a
,
C
a
9
2
6
2
6
T
e
l
:
9
4
9
.
9
7
5
.
0
1
2
3
F
a
x
:
9
4
9
.
2
7
4
.
4
8
3
3
t
e
a
l
e
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
REVISIONS:
Ren. 7/31/19
No. C 22162
M A R K ET
E
LA
AT NEOIFOR
CCLI
ST
R
E N SE D A CHIT
E
AI
T
AT NEOIFOR
ST AI
F CA L
PROPOSED RESIDENCE
F.SHTG: 65.71 (FIRST FLOOR)
PAD: 65.38
TR
O
U
G
H
F.SLAB: 50.78 (BASEMENT FLOOR)
THE PLUG OF AN ABANDONED (EXISTING)
DRIVEWAY, SHALL BE PER STD-165-L.
THE DRIVEWAY PLUG SHALL ALSO INCLUDE THE
SIDEWALK PORTION BEHIND THE SLOPED PORTION
PER CITY STANDARD
REPLACE WITH TURF
DEMO EXIST. DRIVEWAY
OF THE DRIVEWAY APPROACH.
IN PLACE.
NEW PLANTER WALL
-WALL NOT TO EXCEED 42 INCH ABV. EXIST.
GRADE (PRIOR TO CONSTRUCTION.)
SEE LANDSCAPE PLANS
FOR ADD'L INFORMATION
FOOTPRINT OF FIRST FLOOR ABOVE
(SHOWN HEAVY LINE WITH POCHE -TYP.)
EN
T
R
Y
SPA
FOOTPRINT OF FIRST FLOOR ABOVE
(SHOWN HEAVY LINE WITH POCHE -TYP.)
SEE LANDSCAPE PLANS
FOR ADD'L INFORMATION
SEE LANDSCAPE PLANS
FOR ADD'L INFORMATION
SEE LANDSCAPE PLANS
FOR ADD'L INFORMATION
TRASH
TRASH SCREEN WALLS
PATIO BELOW
LINE OF CANOPY
ABOVE
NEW 5FT HIGH POOL SECURITY FENCE
-TUBE STEEL o/3FT PLASTER WALL
UNDER SEPARATE PERMIT TYP.
NEW 5FT HIGH STEEL
POOL SECURITY FENCE
UNDER SEPARATE PERMIT TYP.
NEW 5FT HIGH STEEL
POOL SECURITY FENCE
UNDER SEPARATE PERMIT TYP.
NEW 5FT HIGH POOL SECURITY FENCE
4FT. GLASS o/ 1FT. BLOCK WALL.
UNDER SEPARATE PERMIT TYP.
NEW 42" HIGH GLASS o/ DECK
EDGE -UNDER SEPARATE PERMIT TYP.
TOP OF TROUGH WALL TO BE
SLOPED. NO FLAT LEDGES AT
THIS WALL.
EXIST. GRADE
NEW 5FT HIGH POOL SECURITY FENCE
-TUBE STEEL o/3FT PLASTER WALL
UNDER SEPARATE PERMIT TYP.
EXIST. GRADE
COVERED PATIO
SLOPED PLANTER
A/C - COMPLY WITH CITY
ACOUSTICAL STANDARDS
A/C A/C A/C A/C
COURTYARD BELOW
GATE
OPEN TO SKY
OPEN TO SKY
NEW 42" HIGH GLASS o/ DECK
EDGE -UNDER SEPARATE PERMIT TYP.
GATE
MAIL SLOT
IN GATE
OUTLINE OF
GARAGE BELOW
G A R A G E B E L O W
EXIST. GRADE
EXIST. GRADE
A/C
EXIST. TO
P OF SLOPE
PLANTER
PLANTER
5' HIGH GATE
-BELOW TROUGH
GATE
ELEC. METER
SEE SHT A-2 & A-5
-FIELD INSPECTORS TO REVIEW &
APPROVE UNDERGROUND SERVICE REQ.
PRIOR TO CONC. PLACEMENT
NOTE:
ELECTRICAL SERVICE TO BE UNDER
GROUND FOR NEW CONSTRUCTION OR
FOR ADDITIONS GREATER THAN 50%.
NOTE:
EDISON COMPANY APPROVAL IS
REQUIRED FOR METER LOCATION PRIOR
TO INSTALLATION.
UP UP
PL
A
N
T
E
R
PL
A
N
T
E
R
BBQ
P O O L E D G E
6 5 .1 3
DRIVEWAY
PLANTER BED /
BIO-RETENTION
5
8
.
0
T
W
5
8
.
5
E
G
54.66
T.W.
49.85FG
51.10
F.S.
52.02
F.S.
53.01
F.S.
54.51
F.S.
55.26
T.W.
5 8.5 1
T.F.
55.01F.S 6 2 .51
F.S.
5 8 .0
T .F .
NEW PLANTER WALL
-WALL NOT TO EXCEED 42 INCH ABV. EXIST.
GRADE (PRIOR TO CONSTRUCTION.)
LINE OF CANOPY
ABOVE
GATE
GATE
VICINITY MAP
SITE LEGEND
LINE OF BUILDING FOOTPRINT
PROERTY LINE
SETBACK LINE
TREES
CONTOUR LINES (SEE TOPOGRAPHIC SURVEY AND GRADING PLANS)
SCO
WATER METER
SEWER CLEAN OUT
A/C
AIR CONDITIONING CONDENSER. VERIFY SIZE WITH TITLE 24 REPORT.
SOUND ATTENUATION DESIGN TO BE BE PROVIDED BY CONTRACTOR AT TIME OF
PULLING PERMIT.
-PROVIDE ELEC. DISCONNECT, TO BE VISIBLE FROM UNIT, TO PROTECT
MAINTENANCE PERSONAL DURING REPAIR OR MAINTENANCE.
SEE PAGE 2 OF THE CF1R FOR THE REQUIRED HERS VERIFICATIONS SUMMARY.
PLEASE NOTE THE HERS MEASURE QII, HIGH QUALITY INSULATION INSTALLATION,
NEEDED TO BE USED IN ORDER TO REACH COMPLIANCE. THEREFORE, A HERS RATER
WILL NEED TO BE HIRED TO PERFORM THIS TEST BEFORE THE WALLS ARE CLOSED
IN.
TITLE 24 / HERS INSPECTION
ENERGY NOTES
PER T24, PROVIDE RADIANT BARRIER.
T24 / RADIANT BARRIER
CITY OF NEWPORT BEACH NOTES
ALL DOORS FROM HOUSE TO POOL YARD MUST BE EQUIPPED WITH AN ALARM PER
C.B.C. 3109 & N.B.M.C. 15.04.230. POOL ENCLOSURE AND SAFETY FEATURES SHALL
BE PROVIDED.
DOORS TO POOL
NEW CONSTRUCTION, REQUIRES INSTALLATION OF A FIRE SPRINKLER SYSTEM
THROUGHOUT THE STRUCTURE. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING
FOR ROOF SHEATHING INSPECTION. DEFERRED SUBMITTAL TO BE CERTIFIED BY
PROJECT ARCHITECT PRIOR TO SUBMITTAL.
FIRE SPRINKLERS
EDISON COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO
INSTALLATION.
UTILITY
FIRE PIT WILL BE UNDER SEPARATE PERMIT BUT IT SHALL BE BUILT AT THE SAME
TIME AS THIS PERMIT.
FIRE PIT
A/C UNIT INSTALLATION & LOCATION, POOLS, SPAS, FOUNDATION FOR POOL/SPA,
WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE
SEPARATE REVIEWS AND PERMITS.
SEPARATE PERMITS THE SURVEYOR TO FILE A CORNER RECORD OR RECORD OF SURVEY WITH THE
OFFICE OF COUNTY SURVEYOR. EVIDENCE OF THE FILING SHALL BE SUBMTTED TO
BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION.
CORNER RECORD / RECORD OF SURVEY
ISSUANCE OF A BUILDING PERMIT BY THE CITY DOES NOT RELIEVE APPLICANT OF
THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND
RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN
COMMUNITY ASSOCIATION APPROVAL OF PLANS.
YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO
COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT.
ASSOCIATION APPROVAL ADVISORY
MAINTAIN DRAINAGE PER CITY STANDARDS AND EXISTING CONDITIONS.
CONTRACTOR SHALL TEST THE DRAINAGE TO VERIFY FLOW BEFORE AND AFTER
ADDITION. SHOULD PONDING OR OTHER RESTRICTION OCCUR, CONTACT THE OWNER
AND ARCHITECT IMMEDIATELY.
DRAINAGE
ALL TEMPERED GLASS TO BE ETCH MARKED.
TEMPERED GLASS
WALLS WITHIN 5 FEET OF PROPERTY LINE SHALL BE 1-HOUR FIRE RESISTIVE
CONSTRUCTION.
FIRE RESISTIVE CONSTRUCTION
NEW CONSTRUCTION WITH SLAB ON GRADE SHALL INSTALL A CAPILLARY BREAK IN
COMPLIANCE WITH THE FOLLOWING:
A 2-INCH THICK LAYER OF SAND OVER A VAPOR BARRIER OVER A 4-INCH THICK BASE
OF 1/2-INCH OR LARGER CLEAN AGGREGATE AND A CONCRETE MIX DESIGN WHICH
WILL ADDRESS BLEEDING, SHRINKAGE, AND CURLING. (FOR ADDITIONAL
INFORMATION, SEE AMERICAN CONCRETE INSTITUTE, ACI 302.0R-06)
-PROVIDE A MOISTURE VAPOR RETARDER CONSISTING OF A POLYETHYLENE
MEMBRANE SUCH AS 15-MIL VAPOR BARRIER TO MEET ASTM 1745, OR EQUIVALENT.
REFER TO SOILS REPORT WHICH GOVERNS OVER ARCHITECTURAL AND CIVIL PLANS.
FLOOR SLABS - CAPILLARY BREAK
ALL WORK RELATED TO AIR CONDITIONING CONDENSERS AND POOL AND/OR SPA
EQUIPMENT SHALL BE PERFORMED BY A LICENSED CONTRACTOR AS DESIGN-BUILD
CONSTRUCTION. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC AND POOL
AND/OR SPA EQUIPMENT PER ARI STANDARD 275, PRIOR TO OBTAINING
MECHANICAL OR POOL/SPA PERMITS. SOUND LEVEL NOT TO EXCEED 50 DBA (55DBA
WITH TIMER; 65 DBA WITH TIMER AND NEIGHBOR'S CONSENT) PER SECTION
10.26.045 OF THE NBMC. LOCATION OF MEASUREMENT TO BE ADJACENT PROPERTY
PATIO OR OPENING.
ACOUSTICS
RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65% OF THE NONHAZARDOUS
CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH SECTION 4.408.1
CAL GREEN CODE.
CONSTRUCTION AND DEMOLITION WASTE
THE GENERAL CONTRACTOR SHALL EXTENSIVELY PHOTOGRAPH THE SITE AND
PUBLIC RIGHT-OF-WAY PRIOR TO STARTING DEMOLITION/CONSTRUCTION AS PROOF
OF THE EXISTING CONDITION FOR PUBLIC WORKS DEPARTMENT.
PROOF OF EXISTING CONDITIONS
REMOVAL OF ANY CITY TREES REQUIRES PRIOR APPROVAL FROM GENERAL
SERVICES DEPARTMENT.
TREES -PROTECT CITY TREES IN PLACE
PROVIDE TREES IN THE PARKWAY ADJOINING THIS SITE TO THE SATISFACTION OF
THE GENERAL SERVICES DEPARTMENT. TEL: (949) 644-3083. APPROVAL FROM THE
GENERAL SERVICES DEPARTMENT IS REQUIRED ON THE BUILDING INSPECTION CARD
PRIOR TO FINAL INSPECTION.
TREES
ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE
PERFORMED BY A C-42 LICENSED SANITATION SEWER CONTRACTOR OR AN "A"
LICENSED GENERAL ENGINEERING CONTRACTOR.
WASTEWATER CONTRACTOR
ALL WORK RELATED TO WATER PIPING IN THE PUBLIC RIGHT-OF-WAY SHALL BE
PERFORMED BY A C-34 LICENSED PIPELINE CONTRACTOR OR AN "A" LICENSED
GENERAL ENGINEERING CONTRACTOR.
WATER CONTRACTORCONTRACTOR SHALL RECONSTRUCT ALL DAMAGED/BROKEN CONCRETE CURB,
GUTTER AND SIDEWALK ALONG THE FAIRFIELD ROAD AND ORRRINGTON ROAD
FRONTAGES. -PER CIVIL PLANS.
SITE RECONSTRUCTION
IF ANY OF THE EXISTING PUBLIC IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED,
NEW CONCRETE SIDEWALK, CURB AND GUTTER, ALLEY/STREET PAVEMENT, AND OTHER
PUBLIC IMPROVEMENTS WILL BE REQUIRED BY THE CITY AT THE TIME OF PRIVATE
CONSTRUCTION COMPLETION. ADDITIONALLY, IF EXISTING UTILITIES INFRASTRUCTURE
ARE DEEMED SUBSTANDARD, A NEW 1-INCH WATER SERVICE, WATER METER 2 OF 3
BOX, SEWER LATERAL AND/OR CLEANOUT WITH BOX AND LID WILL BE REQUIRED. 100% OF
THE COST SHALL BE BORNE BY THE PROPERTY OWNER (MUNICIPAL CODES 14.24.020 AND
14.08.030). SAID DETERMINATION AND THE EXTENT OF THE REPAIR WORK SHALL BE MADE
AT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR
ENCROACHMENT PERMIT INSPECTION
PUBLIC WORKS
PLANNING
BUILDING HEIGHT CERTIFICATION UPON COMPLETION OF FRAMING AND PRIOR TO
INSTALLATION OF ANY ROOF MATERIAL MUST BE SUBMITTED.
A HEIGHT CERTIFICATION FROM A LICENSED ENGINEER MUST BE SUBMITTED FOR
SLAB HEIGHT CERTIFICATION PRIOR TO POURING CONCRETE SLAB.
BUILDING HEIGHT
OVERALL CHIMNEY HEIGHT FROM AN INTERIOR FIREPLACE (INCLUDING CAP AND/OR
ARRESTOR) PERMITTED TO EXCEED HEIGHT LIMIT ONLY AS REQUIRED BY C.R.C. OR
MANUFACTURER SPECIFICATION PLUS ADDITIONAL 12" MAXIMUM FOR CAP/SPARK
ARRESTOR. THE PORTION THAT EXCEEDS HEIGHT LIMIT AND C.R.C. MINIMUM IS
LIMITED NOT ONLY TO 12 INCHES IN HEIGHT BUT ALSO 2 FEET BY 4 FEET IN WIDTH
AND DEPTH.
CHIMNEY HEIGHT
DISTANCE FROM FACE OF FOUNDATION TO PROPERTY LINE TO BE ZONING SETBACK
PLUS WALL FINISH THICKNESS (MINIMUM) WHERE NEW CONSTRUCTION OR MORE
THAN 25% ADDED.
WALL FINISH TO PROPERTY LINE -SETBACK
A 4' SIDEYARD SETBACK SHALL BE MAINTAINED UP TO A MAXIMUM HEIGHT OF 8'
ABOVE GRADE BETWEEN PRIMARY ENTRANCE TO ANY DWELLING UNIT AND THE
PUBLIC STREET OR ALLEY AND WITHIN THIS AREA A 3' WIDE UNOBSTRUCTED
WALKWAY SHALL BE PROVIDED. WALKWAY SHALL BE PAVED AND THE ONLY ABOVE
GRADE ENCROACHMENTS PERMITTED IN THIS AREA SHALL BE STEPS ESSENTIAL FOR
USE OF A FIRST FLOOR ENTRANCE.
SIDEYARD
TRASH CAN STORAGE AREA TO BE OUT OF VIEW FROM PUBLIC PLACES AND MAY
NOT BE LOCATED IN REQUIRED PARKING AREAS.
TRASH
PER SECTION 20.65.070 D, SKYLIGHTS MAY PROJECT A MAXIMUM OF 6" ABOVE THE
FINISHED SURFACE OF A CONFORMING ROOF.
SKYLIGHTS
DISTANCE FROM FACE OF FOUNDATION TO PROPERTY LINE TO BE ZONING SETBACK
PLUS WALL FINISH THICKNESS (MINIMUM) WHERE ADDITIONAL AREA IS LESS THAN
25%. EXIST NON CONFORMING IS ACCEPTABLE PER C.N.B.
WALL FINISH TO PROPERTY LINE -SETBACK
OVERLAY DISTRICT -AN ADDITION TO THE PRINCIPAL BUILDING SHALL BE ALLOWED
TO BE CONSTRUCTED TO THE SIDE YARD SETBACK LINE IN EFFECT AT THE TIME THE
PRINCIPAL BUILDING WAS CONSTRUCTED.
SIDE SETBACK
PER CNB 20.30.110 A. 1. ACCESS TO SIDE SETBACK AREA. ON RESIDENTIAL LOTS,
REGARDLESS OF THE SETBACK AREA ENCROACHMENTS ALLOWED BY THIS
SUBSECTION, A MINIMUM THIRTY-SIX (36) INCH WIDE PASSAGEWAY SHALL BE
MAINTAINED WITHIN AT LEAST ONE SIDE SETBACK AREA ADJACENT TO THE
PRINCIPAL STRUCTURE IN COMPLIANCE WITH THE FOLLOWING:
i. THE PASSAGEWAY SHALL BE FREE OF ANY ENCROACHMENTS OR
OBSTRUCTIONS FROM GROUND LEVEL TO A HEIGHT OF EIGHT FEET, INCLUDING
MECHANICAL EQUIPMENT, AND OTHER ITEMS ATTACHED TO, OR DETACHED FROM,
THE PRINCIPAL STRUCTURE;
ii. FENCES AND WALLS LOCATED IMMEDIATELY ADJACENT TO THE PROPERTY
LINE MAY ENCROACH UP TO SIX INCHES. NO REDUCTION OR MODIFICATION TO THIS
REQUIREMENT SHALL BE ALLOWED; AND
iii. THE OPPOSITE SIDE SETBACK AREA MAY HAVE ENCROACHMENTS ALLOWED
BY THIS SUBSECTION.
SIDE YARD ACCESS
A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5 FT. AND FOR
SHORING AND UNDERPINNING.
CAL-OSHA PERMIT
ENCROACHMENT PERMIT
A CITY ENCROACHMENT AGREEMENT IS REQUIRED FOR ALL PRIVATE IMPROVEMENTS
WITHIN THE PUBLIC RIGHT-OF-WAY.
ALL IMPROVEMENTS SHALL COMPLY WITH CITY COUNCIL POLICY L-6 AND L-18
ENCROACHMENT AGREEMENT
PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT
PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT.
TOTAL FRONT YARD AREA: 905 SF
TOTAL IMPERVIOUS LANDSCAPE AREA: 322 SF
322 / 905 = 36% <50%
FRONTYARD -IMPERVIOUS LANDSCAPE AREA
SITE SLOPE CALCULATIONS
SEE ROOF PLAN SHEET FOR SITE SLOPE CALCULATIONS
OVERALL TREE HEIGHT SHALL NOT BE MORE THAN 14 FEET.
NO BAMBOO OR PALM TREES ARE PERMITTED WITHOUT SPECIFIC APPROVAL BY THE
HOMEOWNERS ASSOCIATION PRIOR TO INSTALLATION.
TREE HEIGHT
HOA NOTES
CONTRACTOR
LOT COVERAGE
NOT YET SELECTED
SITE AREA 10,950.93 S.F.
BUILDING FOOTPRINT (AT EAVES) 6,310 S.F.
LOT COVERAGE (AT EAVES)57.62% (60% MAX.)
PROJECT DESCRIPTION
NEW 1-STORY SINGLE FAMILY RESIDENCE WITH BASEMENT
STRUCTURAL / SHORING ENGINEER
PAUL ROHRER STRUCTURAL ENGINEERS
17291 IRVINE BLVD #152
TUSTIN CA 92780
TEL: (714) 486-2537
SURVEYOR
APEX LAND SURVEYING, INC.
HUNTINGTON BEACH, CA 92646
TEL: (714) 488-5006
FAX: (714) 333-4440
LANDSCAPE ARCHITECT
CRAIG DE PFYFFER, PLA, ISA
ENVIRONMENTAL DESIGNS
LANDSCAPE ARCHITECTURE
1278 GLENNEYRE ST. #196
LAGUNA BEACH,CA.92651
TEL: (800) 811-3010
FAX: (800) 811-3014
CRAIG@ENVIRONMENTALDESIGNSLANDSCAPE.COM
CIVIL ENGINEER
JT CONSULTING ENGINEERS
14371 EUCLID ST. #2F
GARDEN GROVE, CA 92843
TEL: (714) 265-1200 CELL: (714) 815-2356
FAX: (714) 276-0372
GEOTECHNICAL ENGINEER
R McCARTHY CONSULTANTING, INC FILE NO: 8184-00
23 CORPORATE PLAZA, SUITE 150 REPORT NO: 20180208-1
NEWPORT BEACH, CA 92660 FEBRUARY 15, 2018
TEL: (949) 629-2539
BUILDABLE AREA
BUILDABLE AREA = 7,016 S.F.
X 1.5 =
MAXIMUM BUILDABLE AREA FOR CATEGORICAL EXEMPTION = 10,524 S.F.
TOTAL HABITABLE AREA + GARAGE:11,365 S.F. S.F. (SEE TABULATION ABV)
SERVICE WILL BE PROTECTED
IN PLACE.
PROJECT DATA
MECHANICAL / PLUMBING ENGINEERING
PROENGINEERING MEP CONSULTANTS
1120 SYCAMORE AVE. 2A
VISTA, CA 92081
TEL: (949) 487-0440
EMAIL: INFO@PROENGINEERINGCONSULTING.COM
FREE OF OBSTRUCTIONS OR ENCROACHMENTS
MIN. 36" WIDE PASSAGE SHALL BE MAINTAINED
-HATCHED AREA -SEE "SIDEYARD" NOTE ABOVE
LANDSCAPE AREAS
TOTAL LANDSCAPE AREA: 2,222 S.F.
TOTAL LAWN AREA:0 S.F.
TOTAL WATER FEATURE AREA: 479 S.F.
THIS PROJECT COMPLIES WITH WATER EFFICIENT LANDSCAPE ORDINANCE.
(SEE LDP-1 AND LDP-2 FOR WELO INFORMATION.)
(SEE WELO PLANS)
1
1
1
SLOPE
2%
SLOPE
2%
SL
O
P
E
2%
1
1
1
SELF-CLOSING,
SELF-LATCHING GATE1
SELF-CLOSING,
SELF-LATCHING GATE1
1
PROPOSED ADJACENT RESIDENCE
DECORATIVE CONC.
ON GRADE, TYP.
1
1
GUARD
1
GATE
SELF-CLOSING,
SELF-LATCHING GATE 1
SLOPE
2%
1
LA
P
P
O
O
L
UN
D
E
R
S
E
P
A
R
A
T
E
P
E
R
M
I
T
UNDER SEPARATE
PERMIT
NEW 5FT HIGH PROPERTY LINE WALL
EXTERIOR PLASTER o/CONC. BLOCK.
UNDER SEPARATE PERMIT, UNDER THIS
PLAN CHECK. PER CITY STANDARD.
EXIST.
PAVING MATERIAL FOR DECORATIVE CARRIAGE WALK AND DRIVEWAY APPROACH
SHALL BE SUBMITTED BY THE GENERAL CONTRACTOR FOR AN ENCROACHMENT
PERMIT / ENCROACHMENT AGREEMENT PRIOR TO ANY WORK IN THE PUBLIC RIGHT
OF WAY. THIS WORK MUST BE COMPLETED BEFORE A BUILDING DEPARTMENT
PERMIT FINAL CAN BE ISSUED.
ENCROACHMENT PERMIT / AGREEMENT
1
1
EXIST. STREET TREES
-PROTECT IN PLACE
1
EXIST. STREET TREE
-PROTECT IN PLACE
1
DECORATIVE CARRIAGE WALK -SEE LANDSCAPE
-SEE ENCROACHMENT PERMIT / AGREEMENT NOTE ABOVE
-NOT TO EXCEED 25% OF THE PARKWAY AREA
CARRIAGE WALK: 40 S.F....PARKWAY: 371 S.F.
= 11% OF PARKWAY AREA
CONTRACTOR SHALL, USE THE CITY STANDARD FORM '30-DAY NOTICE OF INTENT TO
EXCAVATE' TO, NOTIFY ADJACENT PROPERTY OWNERS BY CERTIFIED MAIL 30 DAYS
PRIOR TO STARTING EXCAVATION OR SHORING. CITY STANDARD FORM CAN BE
OBTAINED AT:
HTTP://WWW.NEWPORTBEACHCA.GOV/HOME/SHOWDOCUMENT?ID=17395. PROOF
OF CERTIFIED DELIVERY IS REQUIRED AT THE TIME OF PERMIT ISSUANCE."
EXCAVATION NOTICE
1
EXISTING GAS METER TO BE RELOCATED
TO PRIVATE PROPERTY
1
1
SEE DETAIL: 3/A-4.2
1
1
-SEE L-1 FOR DETAILS
-SEE L-1 FOR DETAILS
-SEE L-1 FOR DETAILS
-SEE L-1 FOR DETAILS
1
1
1
1
1
1
AT LEAST FORTY (40) PERCENT
OF THE PORTION OF THE FENCE OR
WALL ABOVE TWO FEET IS OPEN.
AT LEAST FORTY (40) PERCENT
OF THE PORTION OF THE FENCE OR
WALL ABOVE TWO FEET IS OPEN.
AT LEAST FORTY (40) PERCENT
OF THE PORTION OF THE FENCE OR
WALL ABOVE TWO FEET IS OPEN.
AT LEAST FORTY (40) PERCENT
OF THE PORTION OF THE FENCE OR
WALL ABOVE TWO FEET IS OPEN.
54.66 TW
52.0 EG
53.0 TW56.5 EG
58.0 TF
53.0 TW
52.0 EG
58.0 TF 49.85 FG
5
4
.
6
6
T
W
5
7
.
5
E
G
5 8 .0 T F
5 3 .0 T W
5 8 .0 T F
5 2 .3 E G
54.0 TW53.5 EG
5 2 .5 E G
52.0 FS 5 8 .0 T W
6 5 .0 E G
6
5.0 T
W
6
4.5 E
G
54.66 TW
64.5 EG
57.0 FS
PLANTER
PL
A
N
T
E
R
SHEET INDEX - COASTAL
A-1 SITE PLAN, PROJECT DATA
A-1.1 GENERAL NOTES
A-1.2 WATERPROOFING SPECIFICATIONS
A-1.3 DEMOLITION PLAN
A-1.4 VEHICLE TURN-AROUND
A-2 BASEMENT FLOOR PLAN
A-2.1 FIRST FLOOR PLAN
A-2.2 ROOF PLAN
A-2.3 DOOR AND WINDOW SCHEDULES
A-3 EXTERIOR ELEVATIONS
A-4 BUILDING SECTIONS
A-4.1 BUILDING SECTIONS
A-4.2 BUILDING SECTIONS
A-5 BASEMENT FLOOR ELECTRICAL PLAN /
REFLECTED CEILING PLAN
A-5.1 FIRST FLOOR ELECTRICAL PLAN /
REFLECTED CEILING PLAN
A-6 SQUARE FOOTAGE CALCULATIONS
A-6.1 SQUARE FOOTAGE CALCULATIONS
A-6.2 LOT COVERAGE CALCULATIONS
D-1 ARCHITECTURAL DETAILS
D-2 ARCHITECTURAL DETAILS
T-24A ENERGY CALCULATIONS
T-24B ENERGY CALCULATIONS
C1 PRELIMINARY GRADING PLAN
CPPP CONSTRUCTION POLLUTION PREVENTION PLAN
1 of 1 TOPOGRAPHIC SURVEY
LDP-1 WELO PLAN
LDP-2 PRELIMINARY PLANTING PLAN
L-1 PRELIMINARY HARDSCAPE PLAN (FOR REFERENCE ONLY)
WE
L
O
1
1
7/13/2018 4:35:09 PM
..
.
.
..
.
.
FLAT COATINGS
COATING CATEGORY VOC LIMIT
NONFLAT COATINGS
NONFLAT-HIGH COATINGS
ALUMINUM ROOF COATINGS
BASEMENT SPECIALTY COATINGS
BITUMINOUS ROOF COATINGS
BITUMINOUS ROOF PRIMERS
BOND BREAKERS
CONCRETE CURING COMPOUNDS
CONCRETE/MASONRY SEALERS
DRIVEWAY SEALERS
DRY FOG COATINGS
FAUX FINISHING COATINGS
FLOOR COATINGS
GRAPHIC ARTS COATINGS (SIGN PAINTS)
HIGH TEMPERATURE COATINGS
INDUSTRIAL MAINTENANCE COATINGS
LOW SOLIDS COATINGS
MAGNESITE CEMENT COATINGS
MASTIC TEXTURE COATINGS
FORM-RELEASE COMPOUNDS
SPECIALTY COATINGS
METALLIC PIGMENTED COATINGS
PRETREATMENT WASH PRIMERS
PRIMERS, SEALERS AND UNDERCOATERS
REACTIVE PENETRATING SEALERS
RECYCLED COATINGS
ROOF COATINGS
VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS
(GRAMS OF VOC PER LITER OF COATING, LESS WATER AND LESS EXEMPT COMPOUNDS)
50
150
50
150
100
250
500
420
250
450
100
500
1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER AND INCLUDING EXEMPT COMPOUNDS.
2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE.
3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED
CONTROL MEASURE, FEBRUARY 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD.
FIRE RESISTIVE COATINGS
1
2, 3
MULTICOLOR COATINGS
RUST PREVENTATIVE COATINGS
CLEAR
OPAQUE
SPECIALTY PRIMERS, SEALERS AND UNDERCOATERS
STAINS
STONE CONSOLIDANTS
SWIMMING POOL COATINGS
SHELLACS
TRAFFIC MARKING COATINGS
WATERPROOFING MEMBRANES
WOOD COATINGS
WOOD PRESERVATIVES
ZINC-RICH PRIMERS
250
730
550
100
450
340
100
TUB AND TILE REFINISH COATINGS
100
400
400
420
250
275
350
340
250
50
50
350
350
350
100
350
350
120
250
420
100
350
250
14. PARTICLEBOARD, MEDIUM DENSITY FIBERBOARD (MDF) AND HARDWOOD PLYWOOD USED IN THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL COMPLY WITH LOW FORMALDEHYDE
EMISSION STANDARDS AS SET FORTH IN TABLE 4.504.5 BELOW (4.504.5).
HARDWOOD PLYWOOD VENEER CORE
PRODUCT LIMIT
HARDWOOD PLYWOOD COMPOSITE CORE
PARTICLEBOARD
THIN MEDIUM DENSITY FIBERBOARD
FORMALDEHYDE LIMITS
(MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION)
0.09
1
0.05
MEDIUM DENSITY FOBERBOARD
2
0.11
0.13
0.05
1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR
COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333-96(2002). FOR ADDITIONAL INFORMATION, SEE CALIFORNIA CODE OF REGULATIONS,
TITLE 17, SECTIONS 93120 THROUGH 93120.12
2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 8 MILLIMETERS
15. ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL OR OTHER METHODS ACCEPTABLE TO THE BUILDING
INSPECTOR TO REDUCE THE AMOUNT OF WATER, DUST AND DEBRIS, WHICH MAY ENTER THE SYSTEM UNTIL FINAL STARTUP OF THE HVAC EQUIPMENT. (4.504.1)
16. BATHROOM EXHAUST FANS SHALL EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. UNLESS FUNCTIONING AS A COMPONENT OF
WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF LESS THAN OR EQUAL TO
50% TO MAXIMUM 80%. (4.506.1)
17. DUCT SYSTEMS ARE SIZED, DESIGNED AND EQUIPMENT IS SELECTED USING THE FOLLOWING METHODS (4.507.2):
a. ESTABLISH HEAT LOSS AND HEAT GAIN VALUES ACCORDING TO ANSI/ACCA 2 MANUAL J-2011 (RESIDENTIAL LOAD CALCULATION), ASHRAE HANDBOOKS OR EQUIVALENT DESIGN
METHODS.
b. SIZE DUCT SYSTEMS ACCORDING TO ANSI/ACCA 1 MANUAL D-2014 (RESIDENTIAL DUCT SYSTEMS), ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS.
c. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ANSI/ACCA 3 MANUAL S-2014 (RESIDENTIAL EQUIPMENT SELECTION) OR OTHER EQUIVALENT DESIGN SOFTWARE OR
METHODS.
INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS
18. HVAC SYSTEM INSTALLERS SHALL BE TRAINED AND CERTIFIED TO WORK UNDER THE DIRECT SUPERVISION OF TRAINED AND CERTIFIED INSTALLERS IN THE PROPER INSTALLATION OF HVAC
SYSTEMS. (702.1)
19. HVAC SPECIAL INSPECTORS MUST BE QUALIFIED AND ABLE TO DEMONSTRATE COMPETENCE IN THE DISCIPLINE THEY ARE INSPECTING. (702.2)
DOCUMENTATIONS
20. AN OPERATION AND MAINTENANCE MANUAL, CD, WEB-BASED REFERENCE OR OTHER APPROVED MEDIAL SHALL BE PROVIDED BY THE BUILDER TO THE BUILDING OCCUPANT OR OWNER AT
THE FINAL INSPECTION. IT SHALL INCLUDE OPERATION AND MAINTENANCE INSTRUCTION OF THE EQUIPMENT AND APPLIANCES. (4.410.1)
21. DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT FINISH MATERIALS USED TO COMPLY WITH VOC LIMITS AS SET FORTH IN TABLES 4.504.1, 4.504.2, & 4.504.3. (4.504.2.4)
22. DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPOSITE WOOD PRODUCTS USED COMPLY WITH FORMALDEHYDE LIMITS SET FORTH IN TABLES 4.504.5. (4.504.5.1)
23. DOCUMENTATION WHICH SHOWS COMPLIANCE WITH CAL GREEN CODE INCLUDING CONSTRUCTION DOCUMENTS, PLANS, SPECIFICATIONS, BUILDER OR INSTALLER CERTIFICATION, AND
INSPECTION REPORTS AND VERIFICATION SHALL BE AVAILABLE AT THE FINAL INSPECTION. (703.1)
24. CAL GREEN DOCUMENTATION COMPLIANCE CERTIFICATION FORM (CITY FORM) IS REQUIRED TO BE SUBMITTED TO THE BUILDING INSPECTOR PRIOR TO FINAL BUILDING INSPECTION.
(SECTION 703.1)
CorrList\RESIDENTIAL CALGreenMandatoryMeasures 01/10/2017
CAL GREEN NOTES CAL GREEN NOTES (CONTINUED)
ENERGY EFFICIENCY
3. NEW ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES WITH ATTACHED PRIVATE GARAGES SHALL INSTALL A LISTED NOMINAL 1 INCH INSIDE DIAMETER RACEWAY TO ACCOMODATE A
DEDICATED 208/240 VOLT BRANCH CIRCUIT. (4.106.4.1)
a. THE RACEWAY SHALL ORIGINATE AT THE MAIN SERVICE OR SUBPANEL AND TERMINATE INTO A LISTED CABINET, BOX, OR ENCLOSURE IN CLOSE PROXIMITY TO THE PROPOSED LOCATION
OF AN EV CHARGER.
b.THE SERVICE PANEL OR SUBPANEL SHALL PROVIDE CAPACITY TO INSTALL A MINIMUM 40 AMPERE DEDICATED BRANCH CIRCUIT AND SPACE RESERVED FOR INSTALLATION OF A BRANCH
CIRCUIT OVERCURRENT PROTECTIVE DEVICE.
c. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCURRENT PROTECTIVE DEVICES SPACE RESERVED FOR FUTURE EV CHARGING AS "EV CAPABLE."
d. THE RACEWAY TERMINATION LOCATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE."
ENVIRONMENTAL QUALITY
8. MOISTURE CONTENT OF THE BUILDING MATERIALS USED IN WALL AND FLOOR FRAMING IS CHECKED BEFORE ENCLOSURE ACCORDING TO ONE OF THE FOLLOWING (4.505.3):
9. AEROSOL PAINTS AND COATINGS SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS FOR ROC IN SECTION 94522(A)(2) AND OTHER TOXIC REQUIREMENTS IN SECTIONS 94522(E)(1)
AND (F)(1) OF THE CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94520. (4.504.2.3)
10. CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT WITH OF THE FOLLOWING (4.504.3):
11. MINIMUM 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OF THE FOLLOWING (4.504.4):
12. ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH VOLATILE ORGANIC COMPOUND (VOC) LIMITS SET FORTH IN TABLE 4.504.1 OR TABLE 4.504.2. (4.504.2.1)
SCOPE
1. 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE (CG) IS APPLICABLE TO ALL NEW RESIDENTIAL BUILDINGS, INCLUDING BUT NOT LIMITED TO, DWELLINGS, APARTMENT HOUSES,
CONDOMINIUMS, HOTELS, AND OTHER TYPES OF DWELLINGS CONTAINING SLEEPING ACCOMMODATIONS WITH OR WITHOUT COMMON TOILETS OR COOKING FACILITIES REGULATED BY THE
DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT (HCD-1). (NBMC 15.11.010, CG SECTION 101.3.1).
2. 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE (CG) IS APPLICABLE TO ADDITIONS OR ALTERATIONS OF EXISTING RESIDENTIAL BUILDINGS WHERE THE ADDITION OR ALTERATION
INCREASES THE BUILDING'S CONDITIONED AREA, VOLUME, OR SIZE. THE REQUIREMENTS SHALL APPLY ONLY TO AND/OR WITHIN THE SPECIFIC AREA OF THE ADDITION OR ALTERATION.
(301.1.1)
MATERIAL CONSERVATION AND RESOURCES EFFICIENCY
4. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN SOLE/BOOTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF
RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR OTHER SIMILAR METHOD. (4.406.1)
5. UTILIZE ONE OF THE CITY'S APPROVED FRANCHISE HAULER TO RECYCLE AND/OR SALVAGE A MINIMUM OF 65% OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE. (4.408.1,
4.408.3)
a. MOISTURE CONTENT SHALL BE DETERMINED WITH EITHER A PROBE-TYPE OR CONTACT-TYPE MOISTURE METER. EQUIVALENT MOISTURE VERIFICATION METHODS MAY BE APPROVED BY
THE ENFORCING AGENCY AND SHALL SATISFY REQUIREMENTS FOUND IN SECTION 101.8 OF THIS CODE.
b. MOISTURE READINGS SHALL BE TAKEN AT A POINT 2 FEET (610 MM) TO 4 FEET (1219 MM) FROM THE GRADE STAMPED END OF EACH PIECE TO BE VERIFIED.
c. AT LEAST THREE RANDOM MOISTURE READINGS SHALL BE PERFORMED ON WALL AND FLOOR FRAMING WITH DOCUMENTATION ACCEPTABLE TO THE ENFORCING AGENCY PROVIDED AT
THE TIME OF APPROVAL TO ENCLOSE THE WALL AND FLOOR FRAMING.
a. CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM.
b. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH SPECIFICATION 01350.
c. NSF/ANSI 140 AT THE GOLD LEVEL.
d. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE GOLD.TM
a. VOC EMISSION LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) HIGH PERFORMANCE PRODUCT DATABASE.
b. PRODUCTS CERTIFIED UNDER UL GREENGUARD GOLD
c. CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE PROGRAM.
d. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH SPECIFICATION 01350.
INDOOR CARPET ADHESIVES
ARCHITECTURAL APPLICATIONS VOC LIMIT
CARPET PAD ADHESIVES
OUTDOOR CARPET ADHESIVES
WOOD FLOORING ADHESIVES
RUBBER FLOOR ADHESIVES
SUBFLOOR ADHESIVES
CERAMIC TILE ADHESIVES
VCT AND ASPHALT TILE ADHESIVES
DRYWALL AND PANEL ADHESIVES
COVE BASE ADHESIVES
MULTIPURPOSE CONSTRUCTION ADHESIVES
STRUCTURAL GLAZING ADHESIVES
SINGLE-PLY ROOF MEMBRANE ADHESIVES
OTHER ADHESIVES NOT SPECIFICALLY LISTED
PVC WELDING
ABS WELDING
PLASTIC CEMENT WELDING
ADHESIVE PRIMER FOR PLASTIC
CONTACT ADHESIVE
SPECIAL PURPOSE CONTACT ADHESIVE
STRUCTURAL WOOD MEMBER ADHESIVE
CPVC WELDING
SPECIALTY APPLICATIONS
TOP AND TRIM ADHESIVE
METAL TO METAL
PLASTIC FOAMS
POROUS MATERIAL (EXCEPT WOOD)
WOOD
FIBERGLASS
SUBSTRATE SPECIFIC APPLICATIONS
ADHESIVE VOC LIMIT
(LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER)
50
50
150
100
60
50
65
50
50
50
70
100
250
50
80
30
50
50
30
80
510
490
325
250
550
250
140
250
1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED.
2. FOR ADDITIONAL INFORMATION, REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY
MANAGEMENT DISTRICT RULE 1168.
ARCHITECTURAL
SEALANTS VOC LIMIT
MARINE DECK
NONMEMBRANE ROOF
ROADWAY
SINGLE-PLY ROOF MEMBRANE
OTHER
ARCHITECTURAL
NONPOROUS
SEALANT VOC LIMIT
(LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER)
300
250
760
250
450
420
775
250
MODIFIED BITUMINOUS
MARINE DECK
500
760
SEALANT PRIMERS
POROUS
OTHER 750
13. PAINTS, STAINS, AND OTHER COATINGS SHALL BE COMPLIANT WITH VOC AND OTHER TOXIC COMPOUND LIMITS SET FOURTH IN TABLE 4.504.3. (4.504.2.2)
1, 2
FIXTURE TYPE MAXIMUM FLOW RATE
SINGLE SHOWERHEADS 2 GPM @ 80 PSI
MULTIPLE SHOWERHEADS COMBINED FLOW RATE OF 2 GPM @ 80 PSI
RESIDENTIAL LAVATORY FAUCETS 1.2 GPM @ 60 PSI
COMMON AND PUBLIC USE LAVATORY FAUCETS 0.5 GPM @ 60 PSI
KITCHEN FAUCETS
WATER EFFICIENCY AND CONSERVATION
6. NEW RESIDENTIAL DEVELOPMENTS WITH AN AGGREGATE LANDSCAPE AREA EQUAL TO OR GREATER THAN 500 SQUARE FEET SHALL COMPLY WITH CITY'S WATER EFFICIENT LANDSCAPE ORDINANCE
ordinance. (4.304.0, NBMC 14.17)
7. PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH THE FOLLOWING(4.303.1):
1. INCLUDES SINGLE AND DUAL FLUSH WATER CLOSETS WITH AN EFFECTIVE FLUSH RATE OF 1.28 GALLONS OR LESS
WHEN TESTED PER ASME A122.19.233.2 FOR SINGLE FLUSH AND ASME A112.19.14 FOR DUAL FLUSH TOILETS.
2. LAVATORY FAUCETS SHALL NOT HAVE A FLOW RATE LESS THAN 0.8 GPM AT 20 PSI.
METERING FAUCETS 0.25 GALLONS PER CYCLE MAXIMUM
WATER CLOSETS 1.28 GALLONS / FLUSH
WALL MOUNTED URINAL 0.125 GALLONS / FLUSH
2
1.8 GPM @ 60 PSI3
1
ALL OTHER TYPES OF URINAL 0.5 GALLONS / FLUSH
SYMBOLS
WINDOWS
INSIDE OUTSIDE
PROPERTY LINE
CENTER LINE
SETBACK LINE OR HIDDEN LINE
BENCH MARK
DOOR DESIGNATION
WINDOW DESIGNATION
DETAIL REFERENCE
AIR CONDITIONING CONDENSER AS OCCURS. SEE
T-24A SHEET (ENERGY CALCS) FOR MINIMUM SEER
REQUIRED. COMPLY WITH SOUND REQUIREMENTS.
BATHROOM SINK. PROVIDE FULL HEIGHT POLISHED
PLATE MIRROR, UNLESS NOTED OTHERWISE. SEE
INTERIOR ELEVATIONS WHERE PROVIDED. FAUCET
SHALL COMPLY WITH WATER FLOW REQUIREMENTS.
SECTION REFERENCE
DOORS
STAIRS
1. SEE SCHEDULE FOR DOOR SIZES, FEATURES, MANUFACTURER AND DETAILS. FRONT DOORS SHALL
MAINTAIN 32" CLEAR IN OPEN POSITION. CRC R311.2.
2. FOR RESIDENTIAL PROJECTS: DOORS AND FRAMES FROM 1-HOUR RATED GARAGE TO HOUSE WALLS SHALL
BE RATED NO LESS THAN 20 MINUTE SMOKE CONTROL ASSEMBLY. (THE SEPARATION MAY BE LIMITED TO
THE INSTALLATION OF MATERIALS APPROVED FOR 1-HOUR FIRE RESISTIVE CONSTRUCTION ON THE GARAGE
SIDE AND A SELF CLOSING, TIGHT FITTING, 1-3/8" SOLID CORE WOOD DOOR, STEEL HONEYCOMB-CORE
DOOR, OR A DOOR HAVING A FIRE PROTECTION RATING OF NOT LESS THAN 20 MINUTES IS PERMITTED IN
LIEU OF 1-HOUR ASSEMBLY. DOORS SHALL BE SELF CLOSING AND LATCHING. PER CRC R302.5.1
3. ALL EXTERIOR DOORS SHALL BE WEATHER STRIPPED AT THE HEADS, JAMBS AND SILLS.
1. SEE SCHEDULE FOR DOOR SIZES, FEATURES, MANUFACTURER AND DETAILS.
2. ALL GLASS ADJACENT TO DOORS AND WINDOWS WITHIN 18 INCHES OF WALKING SURFACES SHALL BE
FULLY TEMPERED.
3. ALL WINDOWS SHALL COMPLY WITH ANSI-S-134.1. ALL DOORS SHALL COMPLY WITH ANSI-S-134.2 -1972.
4. ALL GLASS SHALL COMPLY WITH APPLICABLE FEDERAL CONSUMER SAFETY LAWS.
5. EGRESS. ALL BEDROOMS SHALL HAVE EMERGENCY RESCUE WINDOWS OR DOORS.
A. A MINIMUM 5.7 S.F. (5.0 S,F, IS ACCEPTABLE AT GRADE LEVEL) CRC R310.1.1 EXCEPTION
B. MINIMUM NET CLEAR OPENING WIDTH 20 INCHES.
C. MINIMUM NET OPENING HEIGHT 24 INCHES
D. MAXIMUM WINDOW SILL HEIGHT OF 44 INCHES ABOVE FLOOR.
THERE SHALL BE CLEAR ACCESS FROM EMERGENCY ESCAPE OPENING TO A PUBLIC WAY. VERIFY ALL
WINDOWS PRIOR TO ORDERING.
6.**ALL TEMPERED GLASS SHALL BE ETCH MARKED**
STAIRS SHALL BE PER CRC R311.7.
1. SEE PLAN FOR RISE AND RUN. MAXIMUM RISE OF 7.75 INCHES AND MINIMUM RUN (TREAD) OF 10
INCHES. R311.7.4 PROVIDE A NOSING BETWEEN 0.75” AND 1.25” ON STAIRWAYS WITH SOLID RISERS
WHERE TREAD DEPTH IS LESS THAN 11”. R311.7.4.3 AND EXCEPTION 1. MINIMUM WIDTH OF 36 INCHES.
R311.7.1 MINIMUM HEADROOM OF 6 FT. 8 INCHES. R311.7.2
2. WINDER TREADS: A. SHALL HAVE A MINIMUM TREAD DEPTH OF 10 INCHES AT A POINT 12 INCHES FROM
THE NARROW SIDE. R311.7.4.2 B. SHALL HAVE A MINIMUM TREAD DEPTH OF 6 INCHES AT ANY POINT
WITHIN THE CLEAR WIDTH OF THE STAIR
3. LINE PER CRC R311.7.3. 1 12" DIAMETER HANDRAIL SPACED NOT LESS THAN 1 12" FROM WALL. EXTEND
HANDRAILS 6" BEYOND TOP AND BOTTOM RISERS WITH ENDS RETURNED TO WALL OR NEWEL POSTS PER
PLAN. ENCLOSED USABLE SPACE UNDER A STAIR SHALL BE PROTECTED WITH 12" GYP. BOARD MIN.
4. GUARDRAILS SHALL BE 42" ABOVE FINISH FLOOR. INTERMEDIATE PICKETS SHALL BE SPACED SUCH THAT A S
SPHERE 4" IN DIAMETER CAN NOT PASS THROUGH. CRC R312.3 EXP 2 EXCEPT THAT ON SIDES OF A STAIR
THE PICKETS MAY BE SPACED SUCH THAT A SPHERE 4 3/8" MAY NOT PASS THROUGH.
ATTIC VENT AND ACCESS. WHEN ATTIC OCCURS WITH 30" MINIMUM HEADROOM, PROVIDE AN ATTIC
ACCESS 22"x30" (30"x30" WHERE F.A.U. OCCURS) LOCATED IN A CORRIDOR HALLWAY OR OTHER READILY
ACCESSIBLE LOCATION.
PREMANUFACTURED FIREPLACE WITH FLUE AND SPARK ARRESTOR BY "HEATILATOR", "LENNOX", OR "SUPERIOR",
UL REPORT #147, OR EQUAL. PROVIDE FIREPLACE HEARTH PER MANUF. & CODE.
DESA METAL PREMANUFACTURED FIREPLACES. INSTALL PER ICC REPORT ESR #2542.
-FACROTY-BUILT FIREPLACES, CHIMNEYS AND ALL OF HEIR COMPONENTS SHALL BE LISTED IN ACCORDANCE WITH
THEIR LISTING AND MANUFATURER'S INSTALLATION INSTRUCTIONS.
-DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT FIREPLACES EXCEPT
WHERE SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNE SYSTEM AND
AREA INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS.
- PROVIDE A PERMANANEMTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX IN A SOLID FUEL
BURBING FIREPLACE.
-SOLID FUEL BURNING FIREPLACE MUST COMPLY WITH THE CALIFONIA ENERGY STANDARDS NANDATORY
MEASURES"
-GAS APPLIANCE FIREPLACE MST COMPLY WITH THE CALGREEN CODE REQUIREMENTS.
SKYLIGHTS. SKYLIGHTS SHALL BE MANUFACTURED BY BRISTOLITE UNLESS NOTED OTHERWISE. DUAL-PANE
SKYLIGHT. INSTALL PER ICC ESR-3177 AND MANUFACTURER RECOMMENDATIONS. SEE T-24 ENERGY CALCS.
HARDWIRED SMOKE DETECTOR w/BATTERY BACKUP -ALL BEDROOMS AND CORRIDORS/ROOMS LEADING TO
BEDROOMS. BATTERY OPERATED SMOKE DETECTOR ACCEPTABLE IN EXISTING CONSTRUCTION.
CARBON MONOXIDE DETECTOR - HARDWIRED U.N.O - LOCATE NEAR BEDROOMS & AWAY FROM GAS
APPLIANCES AS PER MANUF.'S RECOMMENDATIONS
DESIGNATIONSYM
SYM DESIGNATION
HEATING
PLUMBING
THERMOSTAT
SUPPLY AIR REGISTER -WALL
RETURN AIR REGISTER -WALL
PROVIDE FORCED AIR UNIT, FLUE THROUGH ROOF PER CMC. PROVIDE 6" COMBUSTION AIR DUCT TO OUTSIDE AIR
(WHERE A/C IS REQ'D BY OWNER, PROVIDE COND. AT GRADE ON CONC. PAD. CONCEAL WITH PLANTING).
PROVIDE 2" DIAMETER STEEL BUMPER SET IN CONC. WHERE LOCATED IN GARAGE AND SET ON 18" HIGH
PLATFORM.
SUPPLY AIR REGISTER -CEILING
RETURN AIR REGISTER -CEILING
PROVIDE 120V & 220V OUTLETS, F. GAS, HOT + COLD WATER, AND SEWER CONNECTION. PROVIDE AT DRYER
LOCATION A VENT TO EXTERIOR & LINT TRAP AT ELBOWS PER MANUFACTURERS RECOMMENDATIONS.
HOSE BIBB -PROVIDE ONE AT FRONT OF HOUSE AND ONE AT REAR
FUEL GAS - GAS KEY
SHOWER VALVES SHALL BE PRES. BALANCE THERMOSTAT MIXING VALVE TYPE "ANTI-SCALD"
2.0 GPM FLOWRATE CPC SEC. 410.7. TILE WALLS TO +72" ABOVE THE DRAIN PER T.C.N.A. REQUIREMENTS.
TUB WITH TEMPERED GLASS SHOWER ENCLOSURE
2.0 GPM FAUCET MAX. FLOWRATE
-ACRYLIC U.N.O.
TILE WALLS TO +72" ABOVE DRAIN PER T.C.N.A. REQ'TS
WATER CLOSET - MIN. 30" WIDE SPACE
PROVIDE "LOW FLUSH" TOILETS. 1.28 GALLONS PER FLUSH
KITCHEN SINK
1.5 GPM FAUCET
60 GAL. WATER HEATER -VENT TO OUTSIDE. PROVIDE P&T VALVE w/DRAIN PAN TO EXTERIOR. EARTHQUAKE
STRAP 1/3 FROM TOP & BOTTOM INTO SOLID FRAMING.
A.O. SMITH CYCLONE XHE EXH VENT THROUGH SIDE WALL OR ROOF AS REQ'D. TEL REP. H.C. FLETCHER
(949)660-0200 (DATE 12/00)
SHOWER WITH TEMPERED GLASS (FRAMELESS) ENCLOSURE AND DOOR -PER PLAN.
2.0 GPM FAUCET MAX. FLOWRATE
-ACRYLIC U.N.O.
TILE WALLS TO +72" ABOVE THE DRAIN PER T.C.N.A. REQUIREMENTS
TYPICAL SYMBOLS
REVISION
DECK DRAIN. THUNDERBIRD OR EQUAL.
INSTALL PER MANUFACTURER'S
RECOMMENDATIONS. 1/4 " PER FOOT
MINIMUM SLOPE TO DRAIN. PROVIDE
SEPARATELY PIPED OVERFLOW OR
SCUPPER.
TANKLESS WATER HEATER. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE T-24 ENERGY CALCS.
PROVIDE GAS LINE PIPING FOR TANKLESS WATER HEATER.
WATERPROOFING, EXTERIOR WALL COVERING AND ROOFING
1. SEE PLANS AND ELEVATIONS FOR MATERIAL SPECIFICATIONS. THE CONTRACTOR SHALL OBTAIN A COPY OF
ALL PRODUCT INSTALLATION SPECIFICATIONS, ICC AND UL REPORTS AND HAVE THEM AVAILABLE ON SITE.
2. AT BELOW GRADE WATERPROOFING (W/P) PROVIDE "MIRADRI 860/861" AS MANUFACTURERED BY CARLISLE
COATINGS AND WATERPROOFING (CCW) (800) 527-7092 AS BLIND SIDE WATERPOOFING MEMBRANE.
INSTALL CCW "MIRADRAIN" BACK FILL PROTECTION PRIOR TO BACK FILL. A MANUFACTURER'S
REPRESENTATIVE SHALL INSPECT THE FLASHING AND ROUGH WORK PRIOR TO INSTALLATION. INSTALL PER
MANUF. REPRESENTATIVES RECOMMENDATIONS. (USE MIRACLAY OVER MIRADRAIN WHERE APPLIED TO
LAGGING)
3. WHERE DECK WATERPROOFING OCCURS PROVIDE "DESERT CRETE SYSTEM" BY HILL BROTHERS CEMICAL
CO., ORANGE, CA. (626) 333-2251. CEMENTITIOUS SYSTEM DECK SURFACE, CLASS B. WHERE CLASS A IS
REQUIRED PROVIDE DESERT CRETE SYSTEM OVER DESERT BRAND MAGNESITE SYSTEM. MINIMUM SLOPE
OF DECK AND PLYWOOD SUBFLOOR SHALL BE 1/4" PER 1 FOOT. INSTALL PER ICC REPORT ESR# 1661
4. FLASHING, CORNER BEAD, WEEP SCREED AND EXTERIOR SHEET METAL. PROVIDE FLASHING PER SHEET
METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA) RECOMMENDATIONS.
(714) 547-1821. PROVIDE FLASHING AT VALLEYS, SKYLIGHT AND CHIMNEY PENETRATIONS. SEE ROOF PLAN
FOR "CORROSION RESISTANT SHEET METAL" FOR MATERIAL SPECIFICATION. - WHERE GALVANIZED STEEL
IS USED, PAINT TO MATCH ADJACENT ROOFING. PROVIDE PAN FLASHING UNDER ALL EXTERIOR DOORS.
5. ATTIC VENT. PROVIDE ATTIC VENTILATION AT A RATE OF 1/150 OF THE ATTIC AREA AT THE EAVES. ATTIC
VENTS SHALL BE CORROSION RESISTIVE MATERIAL NOT LARGER THAN 1/4" SQUARE TO PREVENT VARMINT
AND INSECTS FROM ENTERING THE ATTIC. PER UBC. CBC 1505.3 VENTILATION. EXCEPTION 1. THE OPENING
AREA MAY BE 1/300 OF THE AREA OF THE SPACE VENTILATED PROVIDED 50 PERCENT OF THE REQUIRED
OPENING AREA IS PROVIDED BY VENTILATION LOCATED IN THE UPPER PORTION OF THE SPACE TO BE
VENTILATED AT LEAST 3 FEET (914mm) ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE
REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS.
6. ROOFING. ROOFING SHALL BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURERS
RECOMMENDATIONS. INSTALL OVER ROOFING FELT.
7. BLDG PAPER. PROVIDE WEATHER RESISTANT BARRIER: 2 LAYERS 15# BLACK BUILDING PAPER UNDER ALL
EXTERIOR PLASTER. PROVIDE WEATHER RESISTANT BARRIER: 1 LAYER DUPONT "TYVEK" (TYPAR)
HOMEWRAP UNDER ALL EXTERIOR SIDING. PER CBC. INSTALL PER ER-4000. PROVIDE FLASHING AND
SEALANT AROUND ALL EXTERIOR OPENINGS.
8. PRESSURE TREATED LUMBER. UNLESS NOTED OTHERWISE PTDF SHALL BE "PRESERVE" ARSENIC AND
CHROMIUM FREE AS MANUFACTURED BY CHEMICAL SPECIALTIES INC. (CSI, INC.) (800) 421-8661
EXPOSED EXTERIOR WOOD SHALL BE "PRESERVE PLUS" TREATED WITH ACQ PRESERVATIVE AS
MANUFACTURED BY CSI, INC. ALL FASTENERS EXPOSED TO WEATHER SHALL BE CORROSION RESISTANT.
9. FLASHING AROUND WINDOWS SHALL BE SELF-ADHESIVE "PROTECTOWRAP" FLASHING MIN. OR EQUAL
INSTALL PER ESR-1825. WHERE "SISALKRAFT", "BITUTHENE" OR OTHER FIBRE REINFORCED PAPER IS
INDICATED AT OPENINGS USE "PROTECTOWRAP" TYPICAL.
10. ALL CONCRETE TO RECEIVE BOSTIK MOISTURE BARRIER MVP4 AT CONCRETE SLABS, UNDER WOOD
FLOORING AND STONE FLOORING.
11. WATERPROOFING MEMBRANE BELOW TILE SHALL BE LATICRETE 9235 WATERPROOF MEMBRANE. INSTALL
PER ESR-1058 AND MANUFACTURERS RECOMMENDATIONS. ALL INSTALLERS SHALL HAVE A MINIMUM 10
YEARS EXPERIENCE. INSTALL PER MANUFACTURERS REQUIREMENTS. THE GENERAL CONTRACTOR SHALL
MAKE AN APPOINTMENT FOR THE OWNERS, OWNERS REPRESENTATIVE, MANUFACTURER, GENERAL
CONTRACTOR AND INSTALLER TO DISCUSS INSTALLATION DETAILS PRIOR TO COMMENCING WITH WORK.
SUBSTRATE / PLYWOOD SHEATHING MUST BE SLOPED TO DRAIN MIN. 1/4" PER FOOT.
12. WHERE EXTERIOR PAINTED WOOD TRIM IS USED PROVIDE WINDSOR ONE. 7950 REDWOOD DRIVE #4
COTANTI, CA 94931. 707-665-9663 INSTALL PER WINDSOR ONE "EXTERIOR TRIM MANUAL".
GENERAL NOTES
TYPICAL MATERIAL SPECIFICATIONS
CODES
DRAWINGS AND SPECIFICATIONS
LIENS AND INSURANCE
CONTRACTOR (AND OWNER)
1. THE "GENERAL CONDITIONS FOR THE CONTRACT CONSTRUCTION", A.I.A. FORM A-201 IS HEREBY MADE
PART OF THESE SPECIFICATIONS. THE CONTRACTOR SHALL EXECUTE THE CONTRACT WITH THE OWNER ON
AN A.I.A. CONTRACT. CHANGES IN THE WORK SHALL BE ADMINISTERED, AND ADHERED TO, PER A.I.A.
A-201.
2. FIRE PROTECTION SYSTEM DESIGN, PERMITTING, AND CONSTRUCTION SHALL BE THE RESPONSIBILITY OF
THE CONTRACTOR.
3. PATCH AND REPAIR ALL SURFACES DISRUPTED OR DAMAGED DURING CONSTRUCTION TO MATCH
ADJACENT SURFACE EXACTLY TO THE SATISFACTION OF THE ARCHITECT.
4. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING.
5. THE CONTRACTOR SHALL PROVIDE STAKING. PART OF STAKING SHALL INCLUDE CHECKING FINISH FLOOR,
RIDGE AND GRADE HEIGHTS. THIS WORK SHALL BE DONE PRIOR TO STARTING CONSTRUCTION. AND
DISCREPANCY OR CONFLICT BETWEEN THE FINISH FLOOR, ROOF OR GRADE HEIGHTS AND THE
CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY
AND BEFORE PROCEEDING WITH ANY OF THE WORK SO INVOLVED. WHERE A RIDGE HEIGHT IS SHOWN ON
THE ELEVATIONS, SECTIONS, OR ROOF PLAN RELATIVE TO A SURVEY, THE GENERAL CONTRACTOR SHALL
SURVEY THE RIDGE PRIOR TO SETTING RAFTERS OR SHEATHING. REPORT INFORMATION TO THE ARCHITECT
IN WRITING PRIOR TO SETTING RAFTERS OR SHEATHING. ACCOUNT FOR ROOFING THICKNESS IN THE
SURVEY HEIGHT. ARCHITECTURAL DRAWINGS INDICATE TOP OF SHEATHING.
6. THE CONTRACTOR SHALL VERIFY, AND REPORT TO THE ARCHITECT, PRIOR TO BIDDING IF A POST-TENSION
CONCRETE SLAB OCCURS IN EXISTING CONSTRUCTION.
7. THE CONTRACTOR SHALL VERIFY ALL ABBREVIATIONS WITH THE ARCHITECT.
8. MOLD PREVENTION. THE CONTRACTOR SHALL INSTALL ALL ATTIC AND SUBFLOOR VENTILATION AS
INDICATED ON THE DRAWINGS AND SHALL EXCEED BUILDING CODE REQUIREMENTS TO MITIGATE THE
POTENTIAL FOR MOLD. THE CONTRACTOR SHALL PROVIDE A LINE ITEM BID COST FOR MOLD TREATMENT
AND MITIGATION PRIOR TO COVERING THE FRAMING. THE CONTRACTOR SHALL KEEP DRY AND VENTILATE
ALL BUILDING MATERIALS.
9. WHERE DEMOLITION OCCURS, THE CONTRACTOR SHALL VERIFY THAT THE EXTENT OF DEMOLITION DOES
NOT IMPACT THE PERMITS. WHERE EXISTING NON-CONFORMING CONSTRUCTION EXISTS, UNDER NO
CIRCUMSTANCES SHALL ANY WORK BE DEMOLISHED WITHOUT PRIOR NOTIFICATION AND APPROVAL OF THE
ARCHITECT, OWNER AND APPLICABLE AGENCIES. WHERE EXISTING ROTTEN OR DAMAGED MATERIAL NEEDS
TO BE REPLACED NOTIFY THE ARCHITECT AND OWNER PRIOR TO REMOVAL OF ANY MATERIAL.
1. ANY CONFLICT BETWEEN CODES AND THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT IMMEDIATELY AND BEFORE PROCEEDING WITH ANY OF THE WORK SO
INVOLVED.
2. THIS PROJECT SHALL COMPLY WITH THE C.B.C SECURITY PROVISION 1004.3, 1016.4, 1017.11,
1017.12,1019.6, 1005.8.1, 310.4.
3. THIS PROJECT SHALL COMPLY WITH CALIFORNIA ENERGY CONSERVATION STANDARDS FOR
NON-RESIDENTIAL BUILDINGS (OR RESIDENTIAL BUILDINGS -FOR A RESIDENCE).
1. CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. REPORT ANY DISCREPANCIES TO
THE ARCHITECT PRIOR TO STARTING WORK. THE CONTRACTOR SHALL MAKE AND ADD ALL CORRECTIONS
NECESSARY DUE TO NEGLIGENT FIELD VERIFICATION AT HIS OWN EXPENSE.
2. ANY OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR
SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHTIECT BEFORE PROCEEDING WITH ANY
OF THE WORK SO INVOLVED. THE CONTRACTOR OR OWNER SHALL NOT PROCEED WITH ANY WORK UNTIL
THESE ITEMS ARE RESOLVED. THE ARCHITECT IS NOT RESPONSIBLE FOR ANY SUBSURFACE CONDITIONS.
3. DRAWING AND MATERIAL SPECIFICATIONS ARE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A COMPLETE
BUILDING. THE CONTRACTOR SHALL EXECUTE PARTS AND DETAILS EVEN WHEN NOT FULLY SHOWN OR
DESCRIBED. THE CONTRACTOR SHALL EXECUTE NOT FULLY SHOWN OR DESCRIBED PARTS AND DETAILS
ACCORDING TO STANDARD AND CUSTOMARY TRADE PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF
DETAILS WHICH ARE SHOWN ON DRAWINGS OR DESCRIBED IN SPECIFICATIONS.
4. IF DETAILS ARE CONSIDERED UNSOUND, UNSAFE, NOT WATERPROOF, OR NOT WITHIN CUSTOMARY TRADE
PRACTICE, NOTIFY THE ARCHITECT IMMEDIATELY. IF WORK IS PERFORMED, IT WILL BE ASSUMED THAT NO
OBJECTION IS MADE TO THE DETAIL.
5. ANY DEVIATION FROM THE CONSTRUCTION DOCUMENTS OR SPECIFICATIONS BY THE OWNER OR CONTRACTOR
WITHOUT THE ARCHITECT'S APPROVAL RELEASES THE ARCHITECT OR RESPONSIBILITY AND LIABILITY OF ALL
WORK SO INVOLVED. THE ARCHITECT IS NOT RESPONSIBLE FOR CONTRACTOR'S NON COMPLIANCE WITH
CONTRACT DOCUMENTS.
6. THESE DRAWINGS AND/OR SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE THE EXCLUSIVE PROPERTY OF
THE ARCHITECT. RE-USE, REPRODUCTION OF ANY KIND, WITHOUT THE WRITTEN PERMISSION OF THE
ARCHITECT, IS PROHIBITED.
1. THE GENERAL CONTRACTOR SHALL PROVIDE THE OWNER (AND CLIENT WHEN APPLICABLE) WITH CERTIFIED
WAIVER OF LIENS AND CERTIFIED WAIVER OF LIENS BY ALL SUBCONTRACTORS AND SUPPLIERS.
2. THE CONTRACTOR SHALL PROVIDE WORKERS' COMPENSATION INSURANCE, COMPREHENSIVE BODILY
INJURY, FIRE INSURANCE, AND PROPERTY DAMAGE LIABILITY INSURANCE FOR THE DURATION OF THE
PROJECT.
3. PROTECT AND HOLD HARMLESS THE OWNER (AND CLIENT WHERE APPLICABLE) AND HIS
REPRESENTATIVES, ARCHITECTS, AGENTS, ASSIGNS, CONSULTANTS, EMPLOYEES, AND OFFICERS FROM
ANY LIABILITY WHAT-SO-EVER INCLUDING ATTORNEY'S FEES AND EXPENSES, FROM ANY INJURY TO ANY
PERSON, OR PERSONS, OR PROPERTY UNTIL COMPLETION OF THE PROJECT.
4. LIMIT OF ARCHITECTS' LIABILIY. THE OWNER (OR CLIENT WHERE APPLICABLE) AND CONTRACTOR
RECOGNIZE THE INHERENT RISKS CONNECTED WITH CONSTRUCTION AND AGREE TO LIMIT ANY AND ALL
LIABILITY, CLAIM FOR DAMAGES, COST OF DEFENSE, AND EXPENSES TO BE LEVIED AGAINST THE ARCHITECT
ON ACCOUNT OF A DESIGN DEFECT, ERROR, OMISSION, OR PROFESSIONAL NEGLIGANCE TO A SUM NOT TO
EXCEED THE AMOUNT OF THE ARCHITECTS' HOURLY FEE.
1. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE FROM ALL ACCUMULATIONS OF WASTE
MATERIAL OR RUBBISH CAUSED BY HIS EMPLOYEES OR SUBCONTRACTORS. AT THE COMPLETION OF THE
WORK, THE CONTRACTOR SHALL REMOVE ALL RUBBISH, DEBRIS, EQUIPMENT AND SURPLUS MATERIALS FROM
IN AND ABOUT THE PROJECT AND LEAVE THE WORK "BROOM CLEAN."
2. THE CONTRACTOR SHALL VISIT THE SITE AT LEAST ONCE PRIOR TO SUBMITTING A BID.
3. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF UTILITY SERVICES IN THE AREA TO BE EXCAVATED
PRIOR TO ALL EXCAVATION. THE CONTRACTOR SHALL REPAIR ALL DAMAGED UTILITIES DUE TO FAULTY
VERIFICATION.
4. THE CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS ACORDING TO FIRE DEPARTMENT
REQUIREMENTS.
5. THE GENERAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES,
AND FEES REQUIRED BY CITY, COUNTY, AND STATE LAWS, EXCEPT GENERAL BUILDING PLAN CHECK FEE WHICH
WILL BE PAID FOR BY THE OWNER (OR CLIENT WHEN APPLICABLE). THE CONTRACTOR SHALL INCLUDE ALL
THE ABOVE IN CONSTRUCTION.
6. THE GENERAL CONTRACTOR WILL INFORM THE ARCHITECT ONE WEEK PRIOR TO FINAL INSPECTION FOR THE
ARCHITECT TO VISIT THE SITE AS PART OF THE CONTRACT.
7. THE CONTRACTOR SHALL NOT USE ARROW TRUSS CO. IN UPLAND, CA FOR TRUSS REQUIREMENTS
RESIDENTIAL GENERAL NOTES
REQUIRED SETBACK FROM
PROPERTY LINE
0-1 DAY
TIME IN USE
HOURS
REQUIRED SETBACK FROM
ADJACENT STRUCTURES
>1 DAY
10 FEET
20 FEET
5 FEET
5 FEET
JOB SITE VISITS
CONTRACTOR SHALL INFORM THE ARCHITECT PRIOR TO ALL STAGES OF CONSTRUCTION LISTED BELOW. IF THE
ARCHITECT'S ATTENDANCE IS NEEDED, CONTRACTOR AND/OR OWNER SHALL MAKE AN APPOINTMENT WITH THE
ARCHITECT (OR THE ARCHITECT'S REPRESENTATIVE) 3 WORKING DAYS PRIOR TO THE FOLLOWING STAGES OF
CONSTRUCTION. ATTENDANCE BY THE ARCHITECT IS AT THE DISCRECTION OF THE ARCHITECT AND PAYMENT FOR
THIS SERVICE SHALL BE PER CONTRACT.
1. FOUNDATION, PRIOR TO POURING CONCRETE (WHEN NEEDED.)
2. FRAMING, PRIOR TO ROOF FRAMING. (TO REVIEW DUCTING LAYOUT AND ROOF HEIGHTS).
3. LIGHTING (WHERE THE LIGHTING DESIGN IS SOLELY THE RESPOSIBILITY OF THE ARCHITECT).
4. FRAMING, PRIOR TO DRYWALL.
5. AFTER INSTALLATION OF CABINETS AND FLOORING. (WHEN NEEDED.)
CITY RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS
Applicable Standards: 2016 California Residential Code (CRC); 2016 California Building Code (CBC); 2016 California Plumbing Code (CP3); 2016
California Electrical Code (CEC); 2016 California Mechanical Code (CMC); 2016 Building Energy Efficiency Standards (BEES); 2016 California Green
Building Standards Code (CAL GREEN); & Chapter 15 of the Newport Beach Municipal Code (NBMC)
GENERAL:
1. RESIDENTIAL BUILDING UNDERGOING PERMITTED ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL REPLACE NON COMPLIANT PLUMBING
FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES MEETING THE REQUIREMENTS OF 2016 CALIFORNIA GREEN BUILDING STANDARDS
CODE, SECTION 4.303. PLUMBING FIXTURE REPLACEMENT IS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY OR FINAL
INSPECTION BY THE CHIEF BUILDING OFFICIAL. (CIVIL CODE, SECTION 1101.1 ET SEQ., NBMC 15.11.010)
2. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO
OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU
SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT.
3. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS
DEPARTMENT.
4. A SITE SURVEY BY A LICENSED SURVEYOR SHALL BE REQUIRED PRIOR TO FOUNDATION CONCRETE POUR.
5. GARAGE CEILING HEIGHT. THE MINIMUM UNOBSTRUCTED VERTICAL CLEARANCE FOR PARKING SPACES SHALL BE SEVEN FEET, EXCEPT THAT
THE FRONT FOUR FEET MAY HAVE A MINIMUM VERTICAL CLEARANCE OF FOUR FEET.(NBMC 20.40.090 A 4)
6. UTILIZE ONE OF THE CITY'S APPROVED FRANCHISE HAULER TO RECYCLE AND/OR SALVAGE A MINIMUM OF 65% OF THE NON HAZARDOUS
CONSTRUCTION AND DEMOLITION WASTE. (CAL GREEN 4.408.1, 4.408.3)
7. STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES CLEAR WIDTH. (CRC 311.7.1) THE MINIMUM HEAD CLEARANCE SHALL BE 6"-8" MEASURED
VERTICALLY FROM THE SLOPED LINE ADJOINING TREAD NOSING. (CRC 311.7.2)
8. ADVISORY NOTE: HOMEOWNERS ASSOCIATION (HOA) APPROVAL MAY BE REQUIRED FOR THIS IMPROVEMENT.
9. ADDITIONAL PERMITS ARE REQUIRED FOR DETACHED STRUCTORS INCLUDING BUT NOT LIMITED TO:
A. ACCESSORY STRUVTURES, DETACHED PATIO COVERS, AND TRELLISES
B. MASONARY OR CONRETE FENCES OVER 3.5FT HIGH.
C. RETAINING WALLS OVER 4FT HIGH FROM THE BOTTOM OF THE FOUNDATION TO THE TOP OF THE WALL.
CONSTRUCTION:
10. PEDESTRIAN PROTECTION ADJACENT TO PUBLIC WAY TO BE AS FOLLOWS:
11. ALL EXTERIOR LATH AND PLASTER SHALL HAVE TWO LAYERS OF GRADE D PAPER OVER WOOD BASE SHEATHING.(CRC R703.7.3, CBC 2510.6)
12. WALL COVERING OF SHOWERS OR TUBS WITH SHOWERS SHALL BE OF CEMENT PLASTER, TILE, OR APPROVED EQUAL, TO A HEIGHT OF NOT
LESS THAN 72 INCHES ABOVE DRAIN INLET. BACKING FOR TILE SHALL BE CEMENT BOARD OR CEMENT PLASTER. (CRC R307.2, CBC 1210.2.3)
13. SAFETY GLAZING SHALL BE PROVIDED AT THE FOLLOWING HAZARDOUS LOCATIONS: (CRC R308.4, CBC 2406.4)
14. ALL DOORS FROM THE HOUSE INTO THE POOL AREA SHALL BE EQUIPPED WITH AN APPROVED ALARM OR AN APPROVED ALTERNATE
DROWNING PREVENTION SAFETY FEATURE. (CBC 3109.4.4.2)
15. SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (CRC R314.3, CBC 907.2.11.2, 907.2.11.3 & 907.2.11.4):
16. CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (CRC R315.3):
CARBON MONOXIDE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN
ACCORDANCE WITH CRC R315.
17. ALL FENESTRATIONS ON WINDOWS AND DOORS SHALL HAVE U-FACTORS (0.32 MAX) AND SOLAR HEAT GAIN COEFFICIENT (SHGC=0.25 MAX)
VALUES IN ACCORDANCE WITH T-24 ENERGY CALCULATIONS. ALL FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
TEMPORARY GENERATOR:
18. HAND OPERATED CONSTRUCTION TOOLS POWERED BY ELECTRICITY MUST USE POWER PROVIDED BY SOUTHERN CALIFORNIA EDISON
THROUGH A TEMPORARY POLE OR AVAILABLE OUTLET. IN THE RARE CASE WHERE ELECTRICITY IS NOT READILY AVAILABLE AND PORTABLE
TEMPORARY GENERATOR IS NECESSARY, THEN THE FOLLOWING RESTRICTIONS MUST BE ADHERED TO:
FIREPLACE:
19. ALL FIREPLACES:
a. FACTORY-BUILT FIREPLACES, CHIMNEYS, AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN
ACCORDANCE WITH THEIR LISTING AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
b. FACTORY BUILT WOOD BURNING FIREPLACES SHALL BE QUALIFIED AT U.S. EPA'S VOLUNTARY FIREPLACE PROGRAM PHASE 2 EMISSIONS
LEVEL AND BE IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, AND DIVISION 4.5.
c. DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS
ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1005.2, cmc 802.5.2.4)
20. SOLID FUEL BURNING FIREPLACES:
a. PROVIDE A PERMANENTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX OF A SOLID FUEL BURNING FIREPLACE.
b. SOLID FUEL BURNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.
c. CHIMNEY SHALL EXTEND AT LEAST 2 FT. HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10 FT., BUT SHALL NOT BE LESS THAN 3 FT.
ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF. (CRC R1003.9)
d. LIQUID FUELED FIREPLACES ARE NOT ALLOWED FOR INTERIOR USE.
21. DIRECT VENT GAS APPLIANCE:
a. DIRECT VENT SEALED-COMBUSTION GAS APPLIANCE FIREPLACE MUST COMPLY WITH THE CAL GREEN CODE REQUIREMENTS AND MUST
COMPLY WITH ANSI Z21.50. (CAL GREEN 4.503.1)
MECHANICAL
22. ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH AN EXHAUST FAN WITH HUMIDITY
CONTROL SENSOR HAVING A MINIMUM CAPACITY OF 50 CFM DUCTED TO TERMINATE OUTSIDE THE BUILDING. (CRC R303.3, CAL GREEN
4.506.1, CBC 1203.5.2.1, CMC 402.5)
23. WHERE WATER CLOSET COMPARTMENT IS INDEPENDENT OF THE BATHROOM OR SHOWER AREA, A FAN WILL BE REQUIRED IN EACH AREA.
BATHROOMS SHALL HAVE AN EXHAUST FAN WITH HUMIDITY CONTROL SENSOR, MIN. 50 CFM CAPACITY. (CRC R303.3.)
24. WHERE WHOLE HOUSE FANS ARE USED IN BATHROOM AREAS, THE FAN MUST RUN CONTINUOUSLY AND SHALL NOT BE TIED TO A HUMIDITY
CONTROL SENSOR. (CAL GREEN 4.506.1)
25. THE CLOTHES DRYER VENT SHALL NOT EXCEED 14 FEET IN OVERALL LENGTH WITH MAXIMUM TWO 90 DEGREE ELBOWS. (CMC 504.4.2.1)
26. ENVIRONMENTAL AIR DUCTS SHALL TERMINATE MIN 3 FEET FROM PROPERTY LINE OR OPENINGS INTO BUILDING, AND 10 FEET FROM A
FORCED AIR INLET. (CMC 502.2.1)
27. MECHANICAL EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURE'S INSTALLATION INSTRUCTIONS. (CMC 303.1)
28. DOMESTIC RANGE VENTS TO BE SMOOTH METALLIC INTERIOR SURFACE. (CMC 504.3)
29. SUPPLY AND RETURN AIR DUCTS TO BE INSULATED AT A MIN OF R-6. (CAL ENERGY CODE TABLE 150-1-A)
PLUMBING
30 PLUMBING FIXTURES:
31 CLEARANCE FOR WATER CLOSET TO BE A MINIMUM OF 24 INCHES IN FRONT, AND 15 INCHES FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5)
32 THE WATER HEATER BURNER TO BE AT LEAST 18 INCHES ABOVE THE GARAGE FLOOR, IF LOCATED IN A GARAGE. (CPC 507.13)
33 INSTALL A 3 INCH DIAMETER BY 3 FT TALL STEEL PIPE EMBEDDED IN CONCRETE SLAB FOR PROTECTION OF WATER HEATERS LOCATED IN
GARAGE. (CPC 507.13.1)
34 WATER HEATERS TO BE STRAPPED AT TOP AND BOTTOM WITH 1 ½" X 16 GAUGE STRAP WITH 3/8" DIA. X 3" LAG BOLT EACH END.(CPC 507.2)
35 ABS AND PVC DRAIN WASTE AND VENT PIPING MATERIAL IS LIMITED TO 2 STORIES MAX (CPC 701.2(2)(a). AND 903.1.1)
36 ABS AND PVC ROOF AND DECK DRAIN MATERIAL IS LIMITED TO 2 STORIES MAX. (CPC 1101.4)
37 ROOF AND DECK DRAIN SYSTEMS INSIDE THE BUILDING ARE REQUIRED TO BE INSTALLED WITH DIRECTIONAL DWV DRAINAGE FITTINGS.
(CPC 1101.4 AND 706.0)
38 CLEANOUTS ARE REQUIRED WITHIN 2 FEET OF THE CONNECTION BETWEEN THE INTERIOR ROOF AND DECK DRAIN PIPING SYSTEM, AND THE
EXTERIOR ONSITE STORM DRAIN SYSTEM. (CPC 1101.13)
39 ALL HOSE BIBS ARE TO HAVE VACUUM BREAKERS. (CPC 603.5.7)
40 THE MAXIMUM AMOUNT OF WATER CLOSETS ON A 3 INCH HORIZONTAL DRAINAGE SYSTEM LINE IS 3. (CPC TABLE 703.2)
41 THE MAXIMUM AMOUNT OF WATER CLOSETS ON A 3 INCH VERTICAL DRAINAGE SYSTEM LINE IS 4. (CPC TABLE 703.2)
42 PROVIDE GAS LINE WITH A MIN CAPACITY OF 200,000 BTU FOR WATER HEATER. (CAL ENERGY CODE 150.0 (N))
43 PROVIDE A CONDENSATE DRAIN NO MORE THAN 2 INCHES ABOVE THE BASE OF THE WATER HEATER SPACE. (CAL ENERGY CODE 150.0 (N))
44 PROVIDE A STRAIGHT VENT PIPE FROM THE WATER HEATER SPACE TO THE OUTSIDE TERMINATION FROM THE WATER HEATER SPACE. (CAL
ENERGY CODE 150.0 (N))
45 INSULATE ALL HOT WATER PIPES. ( CAL ENERGY CODE 150.0 (J) (2), AND CPC 609.11).
46 ISOLATION VALVES ARE REQUIRED FOR TANKLESS WATER HEATERS ON THE HOT AND COLD SUPPLY LINES WITH HOSE BIBBS ON EACH VALVE,
TO FLUSH THE HEAT EXCHANGER. ( CAL ENERGY CODE 110.3 (7))
ELECTRICAL
47 ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION, REPLACEMENT BUILDING, OR ADDITION TO AN EXISTING BUILDING
EXCEEDS FIFTY (50) PERCENT OF THE GROSS FLOOR AREA OF THE EXISTING BUILDING. ( NBMC 15.32.015)
48 EDISON COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION.
49 FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TO CONCRETE PLACEMENT.
50 SERVICE EQUIPMENT AND SUBPANELS TO HAVE A MIN 30" WIDE BY 36" DEEP CLEAR WORK SPACE. ( CEC 110.26)
51 ALL LIGHTING IS REQUIRED TO BE HIGH EFFICACY. ( CALIFORNIA ENERGY CODE SECTION 150. (K) AND TABLE 150.0-A)
52 PROVIDE A LISTED ONE INCH RACEWAY TO ACCOMMODATE A DEDICATED 208/240-VOLT CIRCUIT FOR FUTURE ELECTRICAL VEHICLE (EV)
CHARGER. ( CAL GREEN 4.106.4)
53 ALL RECEPTACLE OUTLETS ARE REQUIRED TO BE LISTED TAMPER RESISTANT. (CEC 406.12 AND 210.52)
54 COMBINATION TYPE AFCI CIRCUIT BREAKERS ARE REQUIRED FOR ALL 12O VOLT SINGLE PHASE 15/20 AMP BRANCH CIRCUITS. EXCEPT FOR
BATHROOMS, KITCHENS, GARAGES, AND OUTDOORS. (CEC 210.12)
55 AT A MINIMUM, ONE DEDICATED 20 AMP CIRCUIT IS REQUIRED FOR A BATHROOM. (CEC 210.11(C)(3))
56 GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE OUTLETS LOCATED OUTDOORS, GARAGES, ACCESSORY BUILDINGS, BATHROOMS,
CRAWL SPACES, KITCHENS, LAUNDRY AREAS, KITCHEN DISHWASHER BRANCH CIRCUIT, GARBAGE DISPOSAL, ALL AREAS WITHIN 6 FEET OF A
SINK, AND ALL RECEPTACLES WITHIN 6 FEET OF A BATHTUB OR SHOWER STALL. (CEC 210.8)
57 RECEPTACLE OUTLETS ARE NOT ALLOWED WITHIN OR OVER A BATHTUB OR SHOWER STALL. (CEC 406.9(C))
58 SUBPANELS ARE NOT ALLOWED TO BE LOCATED IN BATHROOMS OR CLOTHES CLOSETS. (CEC 240.24 (D) AND (E))
59 CIRCUITS SHARING A GROUNDED CONDUCTOR (NEUTRAL) WITH TWO UNGROUNDED (HOT) CONDUCTORS MUST USE A TWO POLE CIRCUIT
BREAKER OR AN IDENTIFIED HANDLE TIE. (CEC 210.4 (B)) GROUP NON-CABLE CIRCUITS IN PANEL (CEC 210.4 (D))
60 THE RECEPTACLE OUTLETS THAT SERVE KITCHEN COUNTER TOPS, DINING ROOM, BREAKFAST AREA, AND PANTRY, MUST HAVE A MIN OF 2
DEDICATED 20 AMP CIRCUITS. (CEC 210.52 (B)(1))
CBC TABLE 3306.1
PROTECTION OF PEDESTRIANS
HEIGHT OF
CONSTRUCTION
8' OR LESS
MORE THAN 8'
DISTANCE FROM CONSTRUCTION TO LOT LINE
TYPE OF PROTECTION
REQUIRED
5 Feet or more
Less than 5 Feet
None
Construction Railings
Less than 5 Feet
5 Feet or more, but not more than 0ne-fourth the height of construction
Barrier & Covered Walkway
Barrier & Covered Walkway
Barrier
None
5 Feet or more, but between one-fourth and one-half the height of construction
5 Feet or more, but exceeding one-half the height of construction
a. IN EACH SLEEPING ROOM.
b. OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.
c. ON EACH ADDITIONAL STORY, INCLUDING BASEMENTS AND HABITABLE ATTICS.
d. NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER.
e. A MINIMUM OF 20 FEET HORIZONTALLY FROM ANY PERMANENTLY INSTALLED COOKING APPLIANCE.
f. SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE
WITH CRC R314.4 & R314.5 OR CBC 907.2.11.5 & 907.2.11.6.
a. SWINGING, BI-FOLD, AND SLIDING DOORS.
b. WHEN LOCATED WITHIN 60 INCHES ABOVE THE FLOOR OF WET SURFACE SUCH AS TUBS, SHOWERS, SAUNAS, STEAM ROOMS,
OR OUTDOOR SWIMMING POOL.
c. GLAZING ADJACENT TO DOORS:
i. WITHIN A 24 INCH ARC OF EITHER VERTICAL EDGE OF DOORS AND WITHIN 60 INCHES OF WALKING SURFACE.
ii. WHERE THE GLAZING IS ON WALL PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION AND WITHIN 24 INCHES
OF THE HINGE SIDE OF AN IN-SWINGING DOOR.
d. WHERE GLAZING AREA IS MORE THAN 9 SQ. FT. IN AREA, WITH THE BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR,
TOP EDGE MORE THAN 36 INCHES ABOVE FLOOR. AND WITHIN 36 INCHES OF A WALKING SURFACE, MEASURED HORIZONTALLY.
e. GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES ABOVE THE PLANE OF THE ADJACENT
WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN FLIGHTS OF STAIRS AND RAMPS.
f. GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS LESS THAN 36 INCHES ABOVE
THE LANDING AND WITHIN 60 INCHES HORIZONTALLY OF THE BOTTOM TREAD.
g. GLAZING IN GUARDS AND RAILINGS.
a. OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S)
b. ON EVERY LEVEL OF THE DWELLING UNIT INCLUDING BASEMENTS
c. WHERE A FUEL-BURNING APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS ATTACHED
BATHROOM, A CARBON MONOXIDE ALARM SHALL BE INSTALLED WITHIN THE BEDROOM.
a. MUST BE PORTABLE AND MAY BE EASILY RELOCATED.
b. TEMPORARY GENERATORS ARE TO BE LOCATED A MINIMUM DISTANCE FROM ANY PROPERTY LIKE ACCORDING TO THE
FOLLOWING TABLE:
c. IF THE MINIMUM DISTANCE CANNOT BE ACHIEVED, THEN THE GENERATOR SHALL BE LOCATED THE MOST EXTREME DISTANCE
PRACTICAL TO INHIBIT NOISE. OTHER METHODS TO INHIBIT NOISE MAY BE UTILIZED WHEN PRACTICAL.
d. MAY BE OPERATIONAL FOR A MAXIMUM OF FIVE CONSECUTIVE CALENDAR DAYS. AFTER FIVE CONSECUTIVE CALENDAR DAYS
OF USE, POWER SHALL BE PROVIDED THROUGH THE USE OF A TEMPORARY POWER POLE.
e. USAGE IS LIMITED TO WEEKDAYS BETWEEN THE HOURS FROM 8:00 AM AND 3:30 PM MONDAY THROUGH FRIDAY. NO USE
ON THE WEEKENDS OR FEDERAL HOLIDAYS
a. NEW CONSTRUCTION & ADDITION/ALTERATIONS THAT INCREASE CONDITION SPACE AREA, VOLUME, OR SIZE (CG 4.303.1):
i. COMPLY WITH CAL GREEN MANDATORY REQUIREMENTS.
b. ADDITION & ALTERATION: EXISTING FIXTURES SHALL BE REPLACED TO MEET THE FOLLOWING REQUIREMENTS:
i. SHOWER HEADS: 2.0 GPM @ 80 PSI
ii. LAVATORY FAUCETS: 1.2 GPM @ 60 PSI
iii. KITCHEN FAUCETS: 1.8 GPM @ 60 PSI
iv. WATER CLOSET: 1.28 GALLONS PER FLUSH
61 KITCHEN COUNTER TOPS 12 INCHES OR WIDER MUST HAVE A RECEPTACLE OUTLET. (CEC 210.52(C))
62 KITCHEN COUNTER TOPS MUST HAVE RECEPTACLE OUTLETS SO NO POINT ALONG THE COUNTER WALLS
IS MORE THAN 24 INCHES FROM A RECEPTACLE. (CEC 210.52 (C))
63 ISLAND AND PENINSULAR COUNTER TOPS MUST HAVE AT LEAST ONE RECEPTACLE. (CEC
210.52(C)(1),(2),AND (3))
64 THE SPACING FOR GENERAL RECEPTACLE OUTLETS MUST BE LOCATED SO THAT NO POINT ON ANY WALL,
FIXED GLASS, OR CABINETS IS OVER 6 FEET FROM A RECEPTACLE OUTLET. (CEC 210.52(A))
65 HALLWAYS 10 FEET OR MORE MUST HAVE AT LEAST ONE RECEPTACLE OUTLET. (CEC 210.52(H))
66 GARAGES SHALL HAVE AT LEAST ONE RECEPTACLE FOR EACH CAR SPACE ON THE INTERIOR. THE
BRANCH CIRCUIT SUPPLYING THE RECEPTACLES SHALL NOT SERVE OUTLETS OUTSIDE OF THE GARAGE.
(CEC 210.52 (G) (1).
67 LAUNDRY ROOMS MUST HAVE AT LEAST ONE DEDICATED 20 AMP RECEPTACLE CIRCUIT. (CEC
210.11(C)(2)).
68 PROVIDE 120V RECEPTACLE WITHIN 3 FEET OF WATER HEATER. (CAL ENERGY CODE 150.0 (n) 1 A)
FOUNDATION:
69 WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE SHALL BE A MINIMUM OF 4 INCHES ABOVE
THE EARTH OR 2 INCHES ABOVE PAVED AREAS. (CRC R703.7.2.1, CBC 2512.1.2)
70 FASTENERS AND CONNECTORS (NAILS, ANCHOR BOLTS, ETC.) IN CONTACT WITH
PRESERVATIVE-TREATED WOOD SHALL BE OF HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS
STEEL, SILICON BRONZE OR COPPER. (CRC R317.3, CBC 2304.10.5.1)
71 ANCHOR BOLTS SHALL INCLUDE STEEL PLATE WASHERS, A MINIMUM OF 0.229" x 3' x 3" IN SIZE,
BETWEEN SILL PLATE AND NUT. (CRC R602.11.1, CBC 2308.3.2, ACCEPTABLE ALTERNATE SDPWS
4.3.6.4.3)
CorrList\RESIDENTIALConsructionMinimumReq 05/04/2017
SCALE:
START DATE:
SHEET
SH
E
E
T
PR
O
J
E
C
T
2
9
0
0
B
r
i
s
t
o
l
S
t
r
e
e
t
B
u
i
l
d
i
n
g
A
,
S
u
i
t
e
2
0
3
C o
s
t
a
M
e
s
a
,
C
a
9
2
6
2
6
T
e
l
:
9
4
9
.
9
7
5
.
0
1
2
3
F
a
x
:
9
4
9
.
2
7
4
.
4
8
3
3
t
e
a
l
e
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
REVISIONS:
Ren. 7/31/19
No. C 22162
M A R K ET
E
LA
AT NEOIFOR
CCLI
ST
R
E N SE D A CHIT
E
AI
T
AT NEOIFOR
ST AI
F CA L
4/28/17
NO SCALE
GE
N
E
R
A
L
N
O
T
E
S
CO
R
O
N
A
D
E
L
M
A
R
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
7/13/2018 4:36:52 PM
LC
LOT 116
TRACT 3357
M.M. 107/1-7
CL
LOT 117
LOT 115
EXISTING BUILDING
PLANTER
DEMOLITION PLAN
LEGAL DESCRIPTION: TRACT: 3357 LOT: 116
APN# 475-013-06
ZONE R-1-6000
OCCUPANCY GROUP R-3/U (GARAGE)
CONSTRUCTION TYPE TYPE VB, SPRINKLERED
PARKING THREE CAR GARAGE
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
..
.
.
PL
A
N
C
H
E
C
K
#
(BUILDING SHALL BE EQUIPPED WITH AUTOMATIC FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13D)
4/28/17
1/8" - 1'-0"
DE
M
O
L
I
T
I
O
N
P
L
A
N
SCALE:
START DATE:
SHEET
SH
E
E
T
PR
O
J
E
C
T
2
9
0
0
B
r
i
s
t
o
l
S
t
r
e
e
t
B
u
i
l
d
i
n
g
A
,
S
u
i
t
e
2
0
3
C o
s
t
a
M
e
s
a
,
C
a
9
2
6
2
6
T
e
l
:
9
4
9
.
9
7
5
.
0
1
2
3
F
a
x
:
9
4
9
.
2
7
4
.
4
8
3
3
t
e
a
l
e
a
r
c
h
i
t
e
c
t
u
r
e
.
c
o
m
REVISIONS:
Ren. 7/31/19
No. C 22162
M A R K ET
E
LA
AT NEOIFOR
CCLI
ST
R
E N SE D A CHIT
E
AI
T
AT NEOIFOR
ST AI
F CA L
OWNER
ARCHITECT
CONTRACTOR
CODES
PROJECT DATA
VICINITY MAP
TEALE ARCHITECTURE
2900 BRISTOL ST., BLDG A, SUITE 203
COSTA MESA, CA 92626
TEL: (949) 975-0123 FAX: (949) 274-4833
EMAIL: mteale@tealearchitecture.com
MARK TEALE . ARCHITECT C-22162
THE MOINFAR REVOCABLE LIVING TRUST
4501 TREMONT LANE
CORONA DEL MAR, CA 92625
TEL: (949) 975-0123
NOT YET SELECTED
ALL WORK AND MATERIALS SHALL CONFORM STRICTLY TO THE 2016 C.R.C.;
2016 C.B.C.; 2016 C.P.C.; 2016 C.E.C.; 2016 C.M.C.; 2016 CEES (CA ENERGY);
2016 C.G. (CAL GREEN); CHAPTER 15 OF THE NEWPORT BEACH MUNICIPAL
CODE (NBMC); AND ALL OTHER FEDERAL, STATE AND LOCAL CODE.
STRUCTURAL ENGINEER
PAUL ROHRER STRUCTURAL ENGINEERS
17291 IRVINE BLVD #152
TUSTIN CA 92780
TEL: (714) 486-2537
SURVEYOR
APEX LAND SURVEYING, INC.
HUNTINGTON BEACH, CA 92646
TEL: (714) 488-5006
FAX: (714) 333-4440
LANDSCAPE ARCHITECT
CRAIG DE PFYFFER, PLA, ISA
ENVIRONMENTAL DESIGNS
LANDSCAPE ARCHITECTURE
1278 GLENNEYRE ST. #196
LAGUNA BEACH,CA.92651
TEL: (800) 811-3010
FAX: (800) 811-3014
CRAIG@ENVIRONMENTALDESIGNSLANDSCAPE.COM
CIVIL ENGINEER
JT CONSULTING ENGINEERS
14371 EUCLID ST. #2F
GARDEN GROVE, CA 92843
TEL: (714) 265-1200 CELL: (714) 815-2356
FAX: (714) 276-0372
GEOTECHNICAL ENGINEER
R McCARTHY CONSULTANTING, INC FILE NO: 8184-00
23 CORPORATE PLAZA, SUITE 150 REPORT NO: 20180208-1
NEWPORT BEACH, CA 92660 FEBRUARY 15, 2018
TEL: (949) 629-2539
SITE LEGEND
PROERTY LINE
GENERAL SITE NOTES
1. EMPLY NEWPORT BEACH STANDARD EROSION CONTROL MEASURES THROUGHOUT THE
CONSTRUCTION PROCESS.
2. A PUBLIC WORKS DEPT. ENCROACHMENT PERMIT INSPECTION IS REQUIRED BEFORE THE
BUILDING DEPT. PERMIT FINAL CAN BE ISSUED. AT THE TIME OF PUBLIC WORKS DEPT.
INSPECTION, IF ANY OF THE EXISTING PUBLIC IMPROVEMENTS SURROUNDING THE SITE ARE
DAMAGED BY THE PRIVATE WORK, NEW CONCRETE SIDEWALK, CURB, GUTTER,
ALLEY/STREET PAVEMENT, AND OTHER PUBLIC IMPROVEMENTS WILL BE REQUIRED AND
1--% PAID BY THE OWNER. SAID DETERMINATION AND THE EXTENT OF THE REPAIR WORK
SHALL BE MADE AT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR.
3. A CITY ENCROACHMENT PERMIT IS REQUIRED FOR ALL NON-STANDARD PRIVATE
IMPROVEMENTS WITHIN THE PUBLIC RIGHT-OF-WAY.
DEMOLITION NOTES
1. ALL DEBRIS SHALL BE WET AT TIME OF HANDLING TO PREVENT DUST.
2. SEWER LINE SHALL BE CAPPED.
3. ALL BASEMENT FILLS SHALL BE CLEAN AND UNIFORM.
4. STREETS AND SIDEWALKS ARE TO REMAIN CLEAN AND CLEAR.
5. PEDESTRIAN CANOPY PROTECTION REQUIRED IF DEMOLITION WITHIN 10 FEET OF PUBLIC
SIDEWALK.
6. STORM WATER PROTECTION PLAN IS REQUIRED.
CITY OF NEWPORT BEACH NOTES
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE
APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND
REQTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS.
THE CONTRACTOR SHALL CONTACT THE COMMUNITY ASSOCIATIONS PRIOR TO
COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY, AND ENCROACHMENT
PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPT.
EXISTING STRUCTURE TO BE REMOVED
CONSTRUCTION FENCING
DEMOLITION NOTES
CONSTRUCTION FENCING
PROJECT DESCRIPTION
DEMOLISH EXISTING BUILDING ON SITE.
BUILD NEW 1-STORY SINGLE FAMILY RESIDENCE WITH BASEMENT.
7/13/2018 4:41:03 PM
EXISTING BUILDING
..
.
.
..
.
.
4/28/17
1/4" - 1'-0"
BA
S
E
M
E
N
T
F
L
O
O
R
P
L
A
N
FLOOR TO CEILING GLASS
CO
R
O
N
A
D
E
L
M
A
R
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
BASMENT FLOOR PLAN
8
9
10
11
13
14
12
APPLIANCES PER OWNER
HARDWIRED SMOKE DETECTOR w/BATTERY BACKUP BATTERY OPERATED
SMOKE DETECTOR. CARBON MONOXIDE DETECTOR - HARDWIRED U.N.O -
LOCATE NEAR BEDROOMS & AWAY FROM GAS APPLIANCES AS PER
MANUF.'S RECOMMENDATIONS
PROVIDE RECEPTACLES AND LIGHTING PER CODE. LOCATIONS SHOWN FOR
CONCEPT ONLY. VERIFY WITH OWNER. SEE SHEET A-5 FOR ADD'L
INFORMATION.
CLOSET SHELF AND POLE -DOUBLE PER OWNER AND SHELVES
--NOT USED
FORCED AIR UNIT. PROVIDE GAS STUB.
SEE DETAIL FOR ADDITIONAL INFO:
4" DIAMETER DRYER VENT
VENT TO OUTSIDE AIR w/BACK DRAFT DAMPER
WASHER AND DRYER HOOKUP. LEVER FAUCETS
COLD WATER STUD-OUT AND SHUT OFF VALVE IN CABINET ADJACENT TO
REFRIGERATOR FOR ICE MAKER.
3" DIAMETER GALVANIZED STEEL PIPE POST. 36" HIGH.
SEE FOUNDATION PLAN. SEE DETAIL:
ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS,
UNDER-STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED
SIDE WITH 1/2-INCH (12.7 MM) GYPSUM BOARD. CRC R302.7
GARAGE DOOR WITH WEATHERSTRIPPING ALL AROUND.
AS SELECTED BY OWNER.
NEW STAIRS -SEE SYMBOLS -SHEET A-1.1
-WOOD HANDRAIL +36" A.F.F.
ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL OF NOT LESS THAN
1 FOOT CANDLE (11 LUX) AT THREADS AND LANDINGS. CRC R303.6
GUARD +42" A.F.F. OPENINGS (AS OCCUR) BETWEEN PICKETS (AS OCCUR)
SHALL PRECLUDE THE PASSAGE OF A 4" DIA. SPHERE.
ACRALIGHT DUAL-PANE SKYLIGHT WITH ELECTRICAL OPERATION. INSTALL
PER ESR-2415 AND MANUFACTURER RECOMMENDATIONS.
20 FT. CONTINUOUS #4 REBAR UFER GROUND IN FOOTING. STUB OUT 3"
ABOVE FINISH SURFACE. MAINTAIN 3 FT. CLEAR FROM FACE OF ELECTRICAL
PANEL TO ANY WALL SURFACE OR OBSTRUCTION.
DECK: TILE o/MORTAR BED o/ WATERPROOF MEMBRANE PER T.C.N.A.
RECOMMENDATIONS. 1/4" PER FOOT MINIMUM SLOPE. (DROP DECK SHT'G
2-1/2" FROM FLOOR SHT'G AT WALL EDGE TO ACCOMODATE FOR 1-1/2"
MORTAR BED AND TILE)
WATERPROOFING. SEE "WATERPROOF MEMBRANE" SPECIFICATION SHEET
A-1.2. TYPICAL INDICATES MIRADRAIN SHORING CONDITION. FRENCH DRAIN
INDICATES TRADITIONAL SLOPE CUT BACK.
NEW EXTERIOR 2x4 STUD WALL FRAMING AT 16"o.c. U.N.O.
EXTERIOR WALLS (WITH WOOD SIDING) TO HAVE 1/2"
PLYWOOD AT EXTERIOR SIDE. PROVIDE TWO LAYERS GRADE D
PAPER OVER ALL WOOD BASE SHEATHING. 1" SHOWN FOR
EXTERIOR FINISH -SEE STRUCT. DWGS
EXTERIOR WALLS (WITH EXTERIOR PLASTER) TO HAVE WOOD
STRIP FURRING AT EXTERIOR SIDE. PROVIDE TWO LAYERS
GRADE D PAPER OVER ALL WOOD BASE SHEATHING. 1"
SHOWN FOR EXTERIOR FINISH -SEE STRUCT. DWGS
NEW 2x6 STUD WALL FRAMING AT 16"o.c. U.N.O. -SEE
NOTES ABOVE.
NEW 2x8 STUD WALL FRAMING AT 16"o.c. U.N.O. -SEE
NOTES ABOVE.
NEW 2x10 STUD WALL FRAMING AT 16"o.c. U.N.O. -SEE
NOTES ABOVE.
CONCRETE BLOCK WALL
15
16
17
18
19
20
21
22
23
24
25
26
27 WHOLE HOUSE VENTILATION. (NEW CONST AND ADDITIONS >1,000 SF)
PROVIDE A WHOLE-BUILDING MECHANICAL VENTILATION SYSTEM IN
ACCORDANCE WITH THE FAN VENTILATION RATE (ASHRAE SEC. 4.1.1):
MECHANICAL VENTILATION MIN REQ'D. 1 CFM PER 100 SF CONDITIONED
FLOOR AREA PLUS 7.5 CFM FOR EA. OCCUPANT BEDROOM +1. WHOLE
BUILDING VENTILATION SHALL BE PROVIDED BY EXHAUST AIR, SUPPLY AIR
OR COMBINED. NATURAL VENTILATION THROUGH DOORS/WINDOWS OR
CONTINUOUS OPERATION OF FORCED AIR SYSTEM AIR HANDLERS USED IN
CENTRAL FAN INTEGRATED VENTILATIONS SYSTEMS ARE NOT A
PERMISSIBLE METHODS OF PROVIDING WHOLE-BUILDING VENTILATION.
BEES 150(o), EXC.. 5 TO 152(A) & ASHRAE STD. 62.2
PROVIDE: (8313 / 100 CFM PER SF) + (5 X 7.5 CFM) = 120.63 CFM MIN.
EXHAUST FAN, 1 SONE PERMANENTLY ON WITH A NOTE ON THE SWITCH
STATING "VENTILATION CONTROL" "CONTINUOUS OPERATION REQUIRED
WHEN THE HOUSE IS IN USE." SEE FIRST FLOOR PLAN FOR WHOLE HOUSE
VENTILATION FAN. PROVIDE BROAN QTXE150 FAN (150 CFM.)
PREMANUFACTURED GAS BURNING FIREPLACE.
-PROVIDE CLEARANCE TO COMBUSTIBLES PER
MANUFACTURER AND CODE.
-INSTALL PER MANUFACTURERS INSTALLATION
SPECIFICATIONS. -CONTRACTOR TO PROVIDE FIELD
INSPECTOR WITH COPY OF LISTING BY APPROVED LISTING
AGENCY (ICC-ES, WARNOCK-HERSHEY, INTERTEK)
-DAVINCI 72X30
OTL LISTED AND TESTED UNDER:
ANSI Z21.50b-2014 / CSA 2.22b-2014 STANDARDS.
-ORTAL 4070
CSA LISTED AND TESTED UNDER:
ANSI Z21.88 / CSA 2.33-2014 STANDARDS
28
AT KITCHEN VENT. HOOD, LOCAL EXHAUST SYSTEM VENTED TO OUTDOORS
SHALL HAVE A MINIMUM EXHAUST RATE OF 100 CFM. BEES 150(o), EXC. 5
TO 152(a) & ASHRAE STD. 62.2. SEE FIRST FLOOR PLAN FOR KITCHEN VENT.
HOOD.
27a
LIGHT & VENTILATION
NET GLAZING SHALL BE 8% OF THE FLOOR AREA CRC R303.1
NET VENTILATION SHALL BE 4% OF THE FLOOR AREA
GAME ROOM/BAR 114 S.F. WNDW AREA REQ'D 198 S.F. PROVIDED
1414 S.F. 57 OPERABLE WNDW AREA REQ'D 198 S.F. PROVIDED
GYM 28.16 S.F. WNDW AREA REQ'D 120 S.F. PROVIDED
352 S.F. 14.08 OPERABLE WNDW AREA REQ'D 80 S.F. PROVIDED
THEATER SEE "ARTIFICIAL LIGHTING CALC. -THEATER" (SHT A-5)
SEE "MECHANICAL VENTILATION CALC. -THEATER" (SHT A-5)
7 TUB / SHOWER OR SHOWER SURROUND WITH CERAMIC TILE WALLS "MUDSET"
WITH CEMENT PLASTER BACKING o/ WATERPROOF (W/P) MEMBRANE TO +72"
MIN. ABOVE THE DRAIN PER TILE COUNCIL OF NORTH AMERICA. INSTALL W/P
PER ICC ESR-1058. SHOWER HEAD AT +80" A.F.F. PROVIDE BID FOR ONE SOAP
NICHE MINIMUM 18" HIGH 13" WIDE - LOCATION TO BE VERIFIED IN FIELD.
TANKLESS WATER HEATER. PROVIDE P & T VALVE WITH DRAIN TO OUTSIDE.
PROVIDE EARTHQUAKE STRAPPING OR BRACING. PROVIDE HORIZONTAL
VENT TO OUTSIDE. MAINTAIN VENT TERMINATION CLEARANCES PER THE
NATIONAL FUEL GAS CODE (ANSI Z223.1) SEE DETAIL
INSTALL ISOLATION VALVE.
KEY NOTES -FLOOR PLAN
2x6 WOOD FRAMING AT 16"o.c. PER C.R.C. w/
INTERIOR WALL -5/8" GYPSUM BOARD, SMOOTH FINISH
EXTERIOR WALL -7/8" EXTERIOR PLASTER o/METAL LATH o/BUILDING PAPER.
PTDF SILL PLATE AT CONCRETE SLAB
INSULATION PER T-24 SHEEET.
INSULATION THROUGHOUT ALL INTERIOR WALLS AND FLOOR
PLUMBING WALL, AS OCCURS
2x4 WOOD FRAMING AT 16"o.c. PER C.R.C. -SEE NOTE 1 ABOVE.
1
2
3
4
5
6
5/8" TYPE "X" GYPSUM BOARD AT WALLS THROUGHOUT GARAGE TO HOUSE.
5/8" TYPE "X" GYPSUM BOARD AT CEILING. (PROVIDE 2 LAYERS 5/8" TYPE
"X" GYPSUM BOARD AT CEILING WHEN TRUSS JOISTS ARE USED.)
PLUMBING FIXTURES AS SELECTED BY OWNER OR ARCHITECT.
1.28 GALLONS PER FLUSH W/C -SEE PLUMBING SYMBOLS -A-1.1
30"x30" ATTIC ACCESS WITH 30" MINIMUM HEADROOM ABOVE CEILING
TEMPERED GLASS SHOWER ENCLOSURE AND DOOR TO 6'-0" ABOVE THE
DRAIN. DOOR SHALL SWING OUT. PROVIDE 22" MINIMUM WIDE DOOR. NET
AREA OF SHOWER ENCLOSURE SHALL NOT BE LESS THAN 1,024 SQ. INCH
(7.1 SQ. FT.) OF FLOOR AREA, AND A MINIMUM OF 30 INCHES DIAMETER
CIRCLE.
WALL LEGEND
NOTE: VERIFY OVERALL DIMENSIONS PRIOR TO STARTING WORK.
NOTIFY ARCHITECT IMMEDIATELY SHOULD THERE BE ANY DISCREPANCY.
ALL INTERIOR DIMENSIONS SHOWN ARE TO FACE OF STUD U.N.O.
ALL EXTERIOR DIMENSIONS SHOWN ARE TO EXT. FACE OF STUD U.N.O.
OVERALL EXTERIOR DIMENSIONS ARE TO EXT. FACE OF SHTG / FOOTING AS INDICATED
NEW INTERIOR 2x4 STUD WALL FRAMING AT 16"o.c. U.N.O.
-SEE STRUCTURAL DRAWINGS.
-5/8" GYPSUM BOARD INTERIOR WALLS, SMOOTH FINISH
-PROVIDE, AT MOIST AREAS, WATER RESISTANT "GREEN"
GYPSUM BOARD -GREEN BOARD NOT ACCEPTABLE IN
SHOWERS OR TUB SURROUNDS.
PROVIDE 5/8" TYPE "X" GYPSUM BOARD AT GARAGE TO
HOUSE.
PROVIDE WATERPROOF MEMBRANE "BUILDING PAPER" BELOW
ALL EXTERIOR WALL FINISHES.
2x FRAMING AT 16"o.c. -SEE STRUCTURAL.
PROVIDE 8" WOOD TO EARTH SEPARATION OR PRESSURE
TREATED WOOD.
WOOD LOCATED ON CONCRETE SLAB SHALL BE PRESSURE
TREATED.
UP
E L E V A T O R
P O W D E R 2
OPEN TO ABOVE
E Q U I P .
OPEN TO ABOVE
G Y M
L A U N D R Y 2 / S T O R A G E
G Y M B A T H
SEAT
WASH
B A R
DRY
G A R A G E
DN
DNREF.T H E A T E RL O U N G E
TV ABV
L O W E R C O U R T Y A R D
TV ABV
B I K E S T O R A G E
L O W E R P A T I O
E Q U I P
WA
T
E
R
S
O
F
T
E
N
E
R
POOL EQUIP.
TV
SC
R
E
E
N
F.SLAB: 50.28
G A M E R O O M
SLOPE
1/4":FT MIN
20'-0"x10'-0"
CLEAR & UNOBSTRUCTED
PARKING SPACE
20'-0"x10'-0"
CLEAR & UNOBSTRUCTED
PARKING SPACE
20'-0"x10'-0"
CLEAR & UNOBSTRUCTED
PARKING SPACE
S T O R .CAB.
-1/4" FINISH-2" SLAB RECESS
MA
X
.
-1
1
/
2
"
Z
AA
14
T
T
BB
T
19
F
19
F
8
23
9
16
15
17
18
G1
LINE OF TROUGH
ABOVE
PING PONG TABLE
DRY
DR
A
P
E
P
O
C
K
E
T
A
B
O
V
E
6R @ 6.65"EA.
5T @ 12" EA.
2828
LA
D
D
E
R
DR
A
P
E
P
O
C
K
E
T
A
B
O
V
E
8
8
10
T
T A
CORNER OF FNDN. ABV.
CORNER OF FNDN. ABV.
3
3
1
1
1
1
1
3
3
4
4
4
4
4
5
6 7
--NOT USED
--NOT USED
9 9 9
5
9
11
11
11
11
11
11
11
11
11
11
11
10
--NOT USED
--NOT USED
20
--NOT USED
--NOT USED
21
16
26
26
26
14
14
14
14
14
FAU IN
CEILING ABOVE
FAU IN
CEILING ABOVE
FAU IN
CEILING ABOVE
FAU IN
CEILING ABOVE
--NOT USED
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
22T
MAX.
-1 1/2"
2
EGRESS
LADDER
3
3
3 AT
CLG
S T O R A G E
15
DRYER
VENT
UNDER-CABINET
ACCESS FOR DRYER
VENT CLEANOUT
UP 21R @ 6.65"EA.
20T @ 12" EA.
7/13/2018 4:40:38 PM
EXISTING BUILDING
UP UP
PL
A
N
T
E
R
PL
A
N
T
E
R
DN
WALL HUNG
..
.
.
..
.
.
4/28/17
1/4" - 1'-0"
FI
R
S
T
F
L
O
O
R
P
L
A
N
CO
R
O
N
A
D
E
L
M
A
R
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
FIRST FLOOR PLAN
8
9
10
11
13
14
12
APPLIANCES PER OWNER
HARDWIRED SMOKE DETECTOR w/BATTERY BACKUP BATTERY OPERATED
SMOKE DETECTOR. CARBON MONOXIDE DETECTOR - HARDWIRED U.N.O -
LOCATE NEAR BEDROOMS & AWAY FROM GAS APPLIANCES AS PER
MANUF.'S RECOMMENDATIONS
PROVIDE RECEPTACLES AND LIGHTING PER CODE. LOCATIONS SHOWN FOR
CONCEPT ONLY. VERIFY WITH OWNER. SEE SHEET A-5 FOR ADD'L
INFORMATION.
CLOSET SHELF AND POLE -DOUBLE PER OWNER AND SHELVES
--NOT USED
FORCED AIR UNIT. PROVIDE GAS STUB.
SEE DETAIL FOR ADDITIONAL INFO:
4" DIAMETER DRYER VENT
VENT TO OUTSIDE AIR w/BACK DRAFT DAMPER
WASHER AND DRYER HOOKUP. LEVER FAUCETS
COLD WATER STUD-OUT AND SHUT OFF VALVE IN CABINET ADJACENT TO
REFRIGERATOR FOR ICE MAKER.
3" DIAMETER GALVANIZED STEEL PIPE POST. 36" HIGH.
SEE FOUNDATION PLAN. SEE DETAIL:
ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS,
UNDER-STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED
SIDE WITH 1/2-INCH (12.7 MM) GYPSUM BOARD. CRC R302.7
GARAGE DOOR WITH WEATHERSTRIPPING ALL AROUND.
AS SELECTED BY OWNER.
NEW STAIRS -SEE SYMBOLS -SHEET A-1.1
-WOOD HANDRAIL +36" A.F.F.
ALL STAIRWAYS SHALL HAVE AN ILLUMINATION LEVEL OF NOT LESS THAN
1 FOOT CANDLE (11 LUX) AT THREADS AND LANDINGS. CRC R303.6
GUARD +42" A.F.F. OPENINGS (AS OCCUR) BETWEEN PICKETS (AS OCCUR)
SHALL PRECLUDE THE PASSAGE OF A 4" DIA. SPHERE.
ACRALIGHT DUAL-PANE SKYLIGHT WITH ELECTRICAL OPERATION. INSTALL
PER ESR-2415 AND MANUFACTURER RECOMMENDATIONS.
20 FT. CONTINUOUS #4 REBAR UFER GROUND IN FOOTING. STUB OUT 3"
ABOVE FINISH SURFACE. MAINTAIN 3 FT. CLEAR FROM FACE OF ELECTRICAL
PANEL TO ANY WALL SURFACE OR OBSTRUCTION.
DECK: TILE o/MORTAR BED o/ WATERPROOF MEMBRANE PER T.C.N.A.
RECOMMENDATIONS. 1/4" PER FOOT MINIMUM SLOPE. (DROP DECK SHT'G
2-1/2" FROM FLOOR SHT'G AT WALL EDGE TO ACCOMODATE FOR 1-1/2"
MORTAR BED AND TILE)
WATERPROOFING. SEE "WATERPROOF MEMBRANE" SPECIFICATION SHEET
A-1.2. TYPICAL INDICATES MIRADRAIN SHORING CONDITION. FRENCH DRAIN
INDICATES TRADITIONAL SLOPE CUT BACK.
NEW EXTERIOR 2x4 STUD WALL FRAMING AT 16"o.c. U.N.O.
EXTERIOR WALLS (WITH WOOD SIDING) TO HAVE 1/2"
PLYWOOD AT EXTERIOR SIDE. PROVIDE TWO LAYERS GRADE D
PAPER OVER ALL WOOD BASE SHEATHING. 1" SHOWN FOR
EXTERIOR FINISH -SEE STRUCT. DWGS
EXTERIOR WALLS (WITH EXTERIOR PLASTER) TO HAVE WOOD
STRIP FURRING AT EXTERIOR SIDE. PROVIDE TWO LAYERS
GRADE D PAPER OVER ALL WOOD BASE SHEATHING. 1"
SHOWN FOR EXTERIOR FINISH -SEE STRUCT. DWGS
NEW 2x6 STUD WALL FRAMING AT 16"o.c. U.N.O. -SEE
NOTES ABOVE.
NEW 2x8 STUD WALL FRAMING AT 16"o.c. U.N.O. -SEE
NOTES ABOVE.
NEW 2x10 STUD WALL FRAMING AT 16"o.c. U.N.O. -SEE
NOTES ABOVE.
CONCRETE BLOCK WALL
15
16
17
18
19
20
21
22
23
24
25
26
27 WHOLE HOUSE VENTILATION. (NEW CONST AND ADDITIONS >1,000 SF)
PROVIDE A WHOLE-BUILDING MECHANICAL VENTILATION SYSTEM IN
ACCORDANCE WITH THE FAN VENTILATION RATE (ASHRAE SEC. 4.1.1):
MECHANICAL VENTILATION MIN REQ'D. 1 CFM PER 100 SF CONDITIONED
FLOOR AREA PLUS 7.5 CFM FOR EA. OCCUPANT BEDROOM +1. WHOLE
BUILDING VENTILATION SHALL BE PROVIDED BY EXHAUST AIR, SUPPLY AIR
OR COMBINED. NATURAL VENTILATION THROUGH DOORS/WINDOWS OR
CONTINUOUS OPERATION OF FORCED AIR SYSTEM AIR HANDLERS USED IN
CENTRAL FAN INTEGRATED VENTILATIONS SYSTEMS ARE NOT A
PERMISSIBLE METHODS OF PROVIDING WHOLE-BUILDING VENTILATION.
BEES 150(o), EXC.. 5 TO 152(A) & ASHRAE STD. 62.2
PROVIDE: (8313 / 100 CFM PER SF) + (5 X 7.5 CFM) = 120.63 CFM MIN.
EXHAUST FAN, 1 SONE PERMANENTLY ON WITH A NOTE ON THE SWITCH
STATING "VENTILATION CONTROL" "CONTINUOUS OPERATION REQUIRED
WHEN THE HOUSE IS IN USE." SEE FIRST FLOOR PLAN FOR WHOLE HOUSE
VENTILATION FAN. PROVIDE BROAN QTXE150 FAN (150 CFM.)
PREMANUFACTURED GAS BURNING FIREPLACE.
-PROVIDE CLEARANCE TO COMBUSTIBLES PER
MANUFACTURER AND CODE.
-INSTALL PER MANUFACTURERS INSTALLATION
SPECIFICATIONS. -CONTRACTOR TO PROVIDE FIELD
INSPECTOR WITH COPY OF LISTING BY APPROVED LISTING
AGENCY (ICC-ES, WARNOCK-HERSHEY, INTERTEK)
-DAVINCI 72X30
OTL LISTED AND TESTED UNDER:
ANSI Z21.50b-2014 / CSA 2.22b-2014 STANDARDS.
-ORTAL 4070
CSA LISTED AND TESTED UNDER:
ANSI Z21.88 / CSA 2.33-2014 STANDARDS
28
AT KITCHEN VENT. HOOD, LOCAL EXHAUST SYSTEM VENTED TO OUTDOORS
SHALL HAVE A MINIMUM EXHAUST RATE OF 100 CFM. BEES 150(o), EXC. 5
TO 152(a) & ASHRAE STD. 62.2. SEE FIRST FLOOR PLAN FOR KITCHEN VENT.
HOOD.
27a
LIGHT & VENTILATION
NET GLAZING SHALL BE 8% OF THE FLOOR AREA CRC R303.1
NET VENTILATION SHALL BE 4% OF THE FLOOR AREA
LIV/KIT/DIN 119 S.F. WNDW AREA REQ'D 476 S.F. PROVIDED
1483 S.F. 59.5 OPERABLE WNDW AREA REQ'D 476 S.F. PROVIDED
M. BEDROOM 35.68 S.F. WNDW AREA REQ'D 229 S.F. PROVIDED
446 S.F. 17.84 OPERABLE WNDW AREA REQ'D 187 S.F. PROVIDED
BEDROOM 2 15.68 S.F. WNDW AREA REQ'D 38 S.F. PROVIDED
196 S.F. 7.84 OPERABLE WNDW AREA REQ'D 15 S.F. PROVIDED
BEDROOM 3 15.68 S.F. WNDW AREA REQ'D 56 S.F. PROVIDED
196 S.F. 7.84 OPERABLE WNDW AREA REQ'D 15 S.F. PROVIDED
OFFICE 13.20 S.F. WNDW AREA REQ'D 69 S.F. PROVIDED
165 S.F. 6.60 OPERABLE WNDW AREA REQ'D 36 S.F. PROVIDED
7 TUB / SHOWER OR SHOWER SURROUND WITH CERAMIC TILE WALLS "MUDSET"
WITH CEMENT PLASTER BACKING o/ WATERPROOF (W/P) MEMBRANE TO +72"
MIN. ABOVE THE DRAIN PER TILE COUNCIL OF NORTH AMERICA. INSTALL W/P
PER ICC ESR-1058. SHOWER HEAD AT +80" A.F.F. PROVIDE BID FOR ONE SOAP
NICHE MINIMUM 18" HIGH 13" WIDE - LOCATION TO BE VERIFIED IN FIELD.
TANKLESS WATER HEATER. PROVIDE P & T VALVE WITH DRAIN TO OUTSIDE.
PROVIDE EARTHQUAKE STRAPPING OR BRACING. PROVIDE HORIZONTAL
VENT TO OUTSIDE. MAINTAIN VENT TERMINATION CLEARANCES PER THE
NATIONAL FUEL GAS CODE (ANSI Z223.1) SEE DETAIL
INSTALL ISOLATION VALVE.
LAP POOL
SPA
TR
O
U
G
H
A/C A/C
A/C A/C
FACE OF
STUD FACE OF
SHTG / FNDN
FACE OF
STUD FACE OF
SHTG / FNDN
FACE OF
STUD
FACE OF
SHTG / FNDN
FACE OF
STUD
FACE OF
SHTG / FNDN
FACE OF
STUD
FACE OF
SHTG / FNDN
FACE OF
STUD
FACE OF
SHTG / FNDN
FACE OF
STUD
FACE OF
SHTG / FNDN
FACE OF
STUD
FACE OF
SHTG / FNDN
KEY NOTES -FLOOR PLAN
2x6 WOOD FRAMING AT 16"o.c. PER C.R.C. w/
INTERIOR WALL -5/8" GYPSUM BOARD, SMOOTH FINISH
EXTERIOR WALL -7/8" EXTERIOR PLASTER o/METAL LATH o/BUILDING PAPER.
PTDF SILL PLATE AT CONCRETE SLAB
INSULATION PER T-24 SHEEET.
INSULATION THROUGHOUT ALL INTERIOR WALLS AND FLOOR
PLUMBING WALL, AS OCCURS
2x4 WOOD FRAMING AT 16"o.c. PER C.R.C. -SEE NOTE 1 ABOVE.
1
2
3
4
5
6
5/8" TYPE "X" GYPSUM BOARD AT WALLS THROUGHOUT GARAGE TO HOUSE.
5/8" TYPE "X" GYPSUM BOARD AT CEILING. (PROVIDE 2 LAYERS 5/8" TYPE
"X" GYPSUM BOARD AT CEILING WHEN TRUSS JOISTS ARE USED.)
PLUMBING FIXTURES AS SELECTED BY OWNER OR ARCHITECT.
1.28 GALLONS PER FLUSH W/C -SEE PLUMBING SYMBOLS -A-1.1
30"x30" ATTIC ACCESS WITH 30" MINIMUM HEADROOM ABOVE CEILING
TEMPERED GLASS SHOWER ENCLOSURE AND DOOR TO 6'-0" ABOVE THE
DRAIN. DOOR SHALL SWING OUT. PROVIDE 22" MINIMUM WIDE DOOR. NET
AREA OF SHOWER ENCLOSURE SHALL NOT BE LESS THAN 1,024 SQ. INCH
(7.1 SQ. FT.) OF FLOOR AREA, AND A MINIMUM OF 30 INCHES DIAMETER
CIRCLE.
WALL LEGEND
NOTE: VERIFY OVERALL DIMENSIONS PRIOR TO STARTING WORK.
NOTIFY ARCHITECT IMMEDIATELY SHOULD THERE BE ANY DISCREPANCY.
ALL INTERIOR DIMENSIONS SHOWN ARE TO FACE OF STUD U.N.O.
ALL EXTERIOR DIMENSIONS SHOWN ARE TO EXT. FACE OF STUD U.N.O.
OVERALL EXTERIOR DIMENSIONS ARE TO EXT. FACE OF SHTG / FOOTING AS INDICATED
NEW INTERIOR 2x4 STUD WALL FRAMING AT 16"o.c. U.N.O.
-SEE STRUCTURAL DRAWINGS.
-5/8" GYPSUM BOARD INTERIOR WALLS, SMOOTH FINISH
-PROVIDE, AT MOIST AREAS, WATER RESISTANT "GREEN"
GYPSUM BOARD -GREEN BOARD NOT ACCEPTABLE IN
SHOWERS OR TUB SURROUNDS.
PROVIDE 5/8" TYPE "X" GYPSUM BOARD AT GARAGE TO
HOUSE.
PROVIDE WATERPROOF MEMBRANE "BUILDING PAPER" BELOW
ALL EXTERIOR WALL FINISHES.
2x FRAMING AT 16"o.c. -SEE STRUCTURAL.
PROVIDE 8" WOOD TO EARTH SEPARATION OR PRESSURE
TREATED WOOD.
WOOD LOCATED ON CONCRETE SLAB SHALL BE PRESSURE
TREATED.
1
A
B B
ABV ABV
E
F
F
G
H
J
K
L
M
M PP P
Q
S
ABV
T
ABV
T
ABV
U
BLW
T
ABV
T
ABV
T
ABV
T
ABV
V
BLW
T
ABV
W ABVXABVX
ABV
3
4
5
6
7
2
MAIL SLOT
IN GATE
A/C
TV
TV
B E D R O O M 3
B E D R O O M 2
B A T H 3
W . I . C .
W . I . C .
H E R S
B A T H 2SE
A
T
H I S
LINEN
M . B A T H
M . B E D R O O M
H A L L
L I V I N G
D I N I N G
V E S T I B U L E
OPEN TO ABOVE
AND BELOW
E L E V A T O R
B U T L E R ' S P A N T R Y
L A U N D R Y ISLAND
B R I D G E E N T R Y
P O W D E R
OPEN TO BELOW
K I T C H E N
REF
DWDWTR.
MICRO
LINEN
TV ABV
TV ABV
TV ABV
C O V E R E D P A T I O
DRY WASH
O F F I C E
B A T H 1
BENCH
VANITY
OPEN TO SKY
F.SLAB: 65.21
E N T R Y
C O U R T Y A R D
DEPRESSED
FRAMING
T
E
8
8
10
20
8
8
8
911
8
8
911
8
12
12
21
13
T
T E
T A
T A T A
T A
T A
MA
X
.
-7
3
/
4
"
-1/4" FINISH
-2" SLAB RECESS
MAX.
-7 3/4"
-1
/
4
"
F
I
N
I
S
H
-2
"
S
L
A
B
R
E
C
E
S
S
-1
/
4
"
F
I
N
I
S
H
-2
"
S
L
A
B
R
E
C
E
S
S
-1/4" FINISH-2" SLAB RECESS
-1
/
4
"
F
I
N
I
S
H
-2
"
S
L
A
B
R
E
C
E
S
S
9COATS
DRAPE POCKET ABOVE
DR
A
P
E
P
O
C
K
E
T
A
B
O
V
E
D
R
A
P
E
P
O
C
K
E
T
A
B
O
V
E
W I N E
FREEZ.
DR
A
P
E
P
O
C
K
E
T
A
B
O
V
E
DRAPE POCKET ABOVE
DRAPE POCKET ABOVE
DR
A
P
E
P
O
C
K
E
T
A
B
O
V
E
DRAPE POCKET ABOVE
27R @ 6.65"EA.
26T @ 12" EA.
TRASH TRASH
DINING COUNTER
H
T
T
E
E
N
T
T T T
1
1
1
1
1
1
1
1
1
1
1
2
2
2
22
2
--NOT USED
4
4
4
4
4
4
4
4
4
4
4
4
4
--NOT USED
6 7
6 7
6 7
6
9 27A
917
9
9 9
99
TR.DW
11
11
11
11
11
11
11
11 11 11
11
11
11
11
11
11
11
11
11
10
10
10
12
12
12
12
12
12
12
12
16
--NOT USED
--NOT USED
--NOT USED
2122 22
23
25
28
28
28
--NOT USED
--NOT USED
8
8
15
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
W/
H
W/H
6 7
10
10
10
10
SKIYLIGHT
42" HIGH GUARDRAL
AND GATE
EGRESS
LADDER
27
11
SKYLIGHT
CAB
24
T
DRAPE POCKET ABOVE
GAS METER
1
SLOPE
2%
SLOPE
2%
SL
O
P
E
2%
1 1
1
1
1
24
ELEC. METER/
PANEL
1
GATE
SEE A-1
1
GATE
SEE A-1
1
GATE
SEE A-1
1
GATE
SEE A-1
1
GATE
SEE A-1
1
1
7/13/2018 4:46:00 PM
LOT 117
LOT 115
EXISTING BUILDINGROOF PLAN
..
.
.
..
.
.
103.43 F.SLAB. . . . . . .
23.99 . . . . . . . . .
+ .33 . . . . . . . . .
127.75 . . . . . . . . .
-104.73 AVG. N.G. . . . . .
23.02 ABV AVG N.G. . . . .
FINISH SLAB
SHEATHING HEIGHT ABOVE FINISH SLAB
ROOF MATERIAL THICKNESS
TOTAL ROOF HEGHT ABOVE FINISH SLAB
AVERAGE NATURAL GRADE (SEE CALCULATION BELOW)
TOTAL ROOF HEIGHT ABOVE AVERAGE NATURAL GRADE
RIDGE. . . . . . . . . .ROOF LOCATION
SEE "MATERIALS SPECIFICATIONS" AT SHEET A-3 FOR ROOFING MATERIAL
(EXAMPLE NUMBERS BELOW. SEE PLAN FOR ACTUAL HEIGHTS)
NOTE:
ROOF VENTS FOR VENTILATION AT THE UPPER PORTION OF THE SPACE SHALL BE
INSTALLED NO MORE THAN 3 FEET (914mm) BELOW RIDGE
KEY NOTES -ROOF PLAN
LINE OF WALL BELOW
NEW METAL ROOFING o/30# FELT o/ROOF SHEATHING
-SEE "MATERIAL AND COLORS LEGEND", SHEET A-3
R1
R2A
R3
R4
R5
R6
R7
EXTERIOR PLASTER o/METAL LATH o/BUILDING PAPER
STUCCO FINISH AS INDICATED ON ELEVATIONS
BITUTHENE WATERPROOF MEMBRANE UNDER BUILDING PAPER
ON HORIZONTAL (OR NOT VERTICAL) PLASTER PLANES
-SEE "MATERIAL AND COLORS LEGEND", SHEET A-3
FASCIA
-SEE "MATERIAL AND COLORS LEGEND", SHEET A-3
CORROSION RESISTANT SHEET METAL GUTTER AND DOWNSPOUT
DECORATIVE ATTIC VENTILATION -SEE LEGEND A-1
-SEE DETAILS
DECORATIVE CHIMNEY CAP AND SPARK ARRESTOR PER MANUFACTURER
RECOMMENDATIONS. SEE A-1 FOR CITY HEIGHT REQUIREMENTS.
R8 CORROSION RESISTANT SADDLE FLASHING
INSTALL PER SMACNA RECOMMENDATIONS -PAINT
R9
ROOFING
ROOF VENT
REQUIRED ROOF VENTILATION
ROOF HEIGHT LEGEND
CHIMNEY (AND CHIMNEY CAPS, ETC.) HEIGHTS PERMITTED ONLY AS
REQUIRED BY C.R.C. OR MANUFACTURER SPECIFICATIONS PLUS
ADDITIONAL 12" MAXIMUM FOR CAP/SPARK ARRESTOR.
THE PORTION THAT EXCEEDS THE C.B.C./C.R.C. MINIMUM IS LIMITED NOT
ONLY TO 12 INCHES IN HEIGHT BUT ALSO TO 2 FEET BY 4 FEET IN WIDTH
AND DEPTH (N.B.M.C.)
CHIMNEY
ROOF VENTS SUPPLIED BY:
O'HAGIN'S, INC.
Corporate Office & West Coast Mfg. Facility
210 Classic Court, Suite 100, Rohnert Park, California 94928
Phone: 707/303-3660
Toll Free Phone: 800/394-3864
www.OHAGINVENT.com
REQUIRED ROOF VENTILATION -SEE CALC'S
ROOF VENT(S) O'HAGIN'S TAPERED ROOF VENT 72.00 SQ. IN. F.A.M.
LOUVER: GALV. STEEL -PAINT TO MATCH ROOFING. BACKED WITH 1/4"
MESH GALV. WIRE CLOTH
ROOF VENT(S) (O'HAGIN'S TEMPERED FLAT OR EQUAL)
REQUIRED ROOF VENTILATION -SEE CALCULATIONS BELOW.
ROOF VENT: CORROSION REISTANT METAL -PAINT TO MATCH ROOFING
BACKED WITH 1/4" MESH GALV. WIRE CLOTH. 1/8" MINIMUM OPENINGS.
CORROSION RESISTANT SHEET MTL
NOTE TO CONTRACTOR:
ROOF VENTILATION CALCULATIONS PROVIDED HERE SHALL NOT BE USED
FOR ROOFING MATERIAL TAKE-OFFS/CALCULATIONS/ETC.
CRC R806.2 ROOF VENTILATION - THE MINIMUM NET FREE VENTILATION
AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE.
EXCEPTION:
THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/300 OF THE
VENTED SPACE PROVIDED ONE OR MORE OF THE FOLLOWING CONDITIONS
ARE MET: THAT AT LEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT
OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS
LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER
VENTILAORS SHALL BE LOCATED NO MORE THAN 3 FEET (914MM) BELOW
THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY,
WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR
CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING
MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS,
INSTALLATION MORE THAN 3 FEET (914MM) BELOW THE RIDGE OR HIGHEST
POINT OF THE SPACE SHALL BE PERMITTED.
(SEE "GENERAL NOTES - SECTIONS" [SHT A-3] FOR VAPOR RETARDER NOTE)
D.D.
+2"
OVERFLOW DECK DRAIN OVERFLOW, TO BE PIPED SEPARATELY FROM
DECK DRAIN. SEE DETAIL 16/D2
LEGEND
DECK DRAIN. SEE DETAIL 17/D2 & 19/D2
ROOF VENT. SEE KEYNOTE 9, THIS SHEET.
D.S.
GUTTER AND DOWNSPOUT
WHERE INDICATED ON THE DRAWINGS AS "CORROSION RESISTANT SHEET METAL"
THE CONTRACTOR SHALL PROVIDE GALV STEEL OR CORROSION RESISTANT
FLASHING. PROVIDE BACKPRIME AT DISSIMILAR METALS, INSTALL PER S.M.A.C.N.A.
4/28/17
1/4" - 1'-0"
RO
O
F
P
L
A
N
SL
O
P
E
2:
1
2
LOW ROOF
HIP
D.S.
NEW TPO ROOFING o/30# FELT o/ROOF SHEATHING
-SEE "MATERIAL AND COLORS LEGEND", SHEET A-3R2B
R2A TYP.
METAL ROOFING
R5 TYP.
R5 TYP.
R11 WALL VENTS (FOR ROOF VENTILATION). C & J METAL PRODUCTSLV1424
(14"WX24"H) CORROSION RESISTANT W/ WEATHER RESISTANT LOUVER
AND BACKED WITH 1/4 " MESH GALV. WIRE CLOTH. 1/ 8" MIN OPENINGS.
WHERE "SKYLIGHTS" ARE INDICATED ON THE DRAWINGS PROVIDE
BRISTOLITE FIBROLITE INDUSTRIES INC., (714) 540-8950
INSTALL ALL SKYLIGHTS PER MANUFACTURERS RECOMMENDATIONS AND
DETAILS. INSTALL PER ICC REPORT - ESR-3177 (RENEWAL 5/1/2015 )
NOTE:
BUBBLE OR DOMED SKYLIGHT NOT ALLOWED ON SLOPE ROOF PER HOA.
BRISTOLITE AL-CM-2-P (PYRAMID- (ONE PIECE ACRYLIC))
FRAME FINISH: BRONZE ANODIZED ALUMINUM
LENS TYPE: PYRAMID
LENS MATERIAL: ACRYLIC
LENS OUTER COLOR: BRONZE (OUTER)
LENS INNER COLOR: BRONZE (INNER)
SKYLIGHTS
R10 SKYLIGHT. SEE "SKYLIGHTS" NOTE, THIS SHEET. SEE DTLS:
EAVE
ROOF
EDGE
ROOF
EDGE
CO
R
O
N
A
D
E
L
M
A
R
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
66.85 + 63.82 + 64.55 + 64.86 = 260.08 / 4 = 65.02 AVG N.G.
65.02 AVG N.G. + 24.OO = 89.02 MAX FLAT ROOF/GUARDRAIL
65.02 AVG N.G. + 29.OO = 94.02 MAX RIDGE
MAX. ROOF HEIGHT CALC'S
AVGERAGE NATURAL GRADE /
66.85 - 63.82 = 3.03
3.03 / 97.69' = 0.0310
0.0310 x 100 = 3.10% = LESS THAN 5%
SEE SHEET A-1 FOR ADDITIONAL INFORMATION
SITE SLOPE CALCULATION
SLOPE
2:12
HIP
R4 TYP.
SLOPE
2:12
R1TYP.
ROOF TO
WALL
ROOF
EDGESLOPE
2:12
VA
L
L
E
Y
LOW ROOF
NOTE:
ALL EAVE DIMENSIONS
ARE TO FACE OF STUD -TYP.
SLOPE
2:12
SLOPE
2:12
SLOPE
2:12
SL
O
P
E
2:
1
2
SL
O
P
E
2:
1
2
SL
O
P
E
2:
1
2
SL
O
P
E
2:
1
2
SL
O
P
E
2:
1
2
SL
O
P
E
2:
1
2
SLOPE
2:12
SLOPE
2:12
SL
O
P
E
2:
1
2
SL
O
P
E
2:
1
2
SL
O
P
E
2:
1
2
SL
O
P
E
2:
1
2
SL
O
P
E
2:
1
2
SLOPE
3/8:12
SLOPE
3/8:12OPEN TO
BELOW
RIDGE RIDGE
RIDGE
RI
D
G
E
RI
D
G
E
RI
D
G
E
RO
O
F
E
D
G
E
SLOPE
2:12
RO
O
F
E
D
G
E
ROOF EDGE
"FLAT" ROOF
"FLAT" ROOF
"FLAT" ROOF
OPEN TO
COURTYARD BELOW
VA
L
L
E
Y
VALLEY
VA
L
L
E
Y
VALLEY
VALLEY
VALLEY
VA
L
L
E
Y
VA
L
L
E
Y
VALLEY
VALLEY
VA
L
L
E
Y
D.S.
D.S.
D.S.
D.S.
SL
O
P
E
1
/
2
:
1
2
R1 TYP.
R1 TYP.
1 TYP.
R1 TYP.
R2A TYP.
METAL ROOFING
R2A TYP.
METAL ROOFING
R2A TYP.
METAL ROOFING
R2A TYP.
METAL ROOFING
R2B ROOFING
TPO
R2B ROOFING
TPO
R2B ROOFING
TPO
R2B ROOFING
TPO
R4
R5 TYP.
R5 TYP.
R5TYP.
R5TYP.
R5 TYP.
R7
FIREPLACE
FLUE
R7 FIREPLACE
FLUE
D.S.
SL
O
P
E
3/
8
:
1
2
SL
O
P
E
2:
1
2
RI
D
G
E
D.S.
R5
R9 TYP.
ROOF VENT
R11VENT
RIDGE
-TYP.
RIDGE
-TYP.
VALLEY
-TYP.
VALLEY
-TYP.
VALLEY
-TYP.
EAVE
-TYP.
ROOF
EDGE
ROOF
EDGE
ROOF RAKE
-TYP.
ROOF RAKE
-TYP.
ROOF RAKE
-TYP.
ROOF RAKE
-TYP.
ROOF RAKE
-TYP.
ROOF RAKE
-TYP.
8
RI
D
G
E
RI
D
G
E
ROOF RAKE
-TYP.
SL
O
P
E
3/
8
:
1
2
SLOPE 3/8:12
LINE OF CITY SETB
ACK
R7 FIREPLACE
FLUE
EXIST. TO
P OF SLOPE
245"x37"
SKYLIGHT
R8 FLASHING
SADDLE
R10 SKYLIGHT
R11 VENT
R11VENT
R11 VENT
R11VENT R11VENT
R O O F A
R O O F B
ROOF A
REQUIRED NET FREE VENTILATING AREA:
ATTIC SQ. FT. 326/150=2.17 S.F. (313 SQ.IN.) VENT AREA REQ'D
NET FREE VENTILATING AREA AT UPPER PORTION OF THE SPACE:
CONTRACTOR TO PROVIDE & INSTALL: ONE (1)
WALL VENT(S): C & J METAL PRODUCTS LV1424: 336 SQ. IN. F.A.M.
TOTAL ROOF VENT VENTING: 336 SQ. IN.
ROOF VENT: CORROSION RESISTANT METAL -PAINT TO MATCH ROOFING
BACKED w/ 1/4" MESH GANVANIZED WIRE CLOTH. 1/8" MIN. OPENING
ROOF B
REQUIRED NET FREE VENTILATING AREA:
ATTIC SQ. FT. 2,063/150=13.75 S.F. (1,980 SQ.IN.) VENT AREA REQ'D
NET FREE VENTILATING AREA AT UPPER PORTION OF THE SPACE:
CONTRACTOR TO PROVIDE & INSTALL: SIX (6)
WALL VENT(S): C & J METAL PRODUCTS LV1424: 336 SQ. IN. F.A.M.
TOTAL ROOF VENT VENTING: 2,016 SQ. IN.
ROOF VENT: CORROSION RESISTANT METAL -PAINT TO MATCH ROOFING
BACKED w/ 1/4" MESH GANVANIZED WIRE CLOTH. 1/8" MIN. OPENING
R11 VENT
1
1
7/13/2018 4:46:54 PM
LEFT SIDE ELEVATION
PR
O
P
E
R
T
Y
L
I
N
E
PAD (EXIST. F.F. -4")
F.SLAB: 65.71
H.O.A. HEIGHT LIMIT -"FLAT" ROOF
H.O.A. HEIGHT LIMIT -RIDGE
PLATE & WNDW HD
(THIS LOCATION)
HIGHES
TRIDGE
79.
30
HIG
H
E
S
T
RID
G
E
79
.
3
0
D.S.
D.S.
NEW 5FT HIGH TUBE STEEL
POOL SECURITY FENCE ALONG P.L.
UNDER SEPARATE PERMIT TYP.
-SEE LANDSCAPE FOR MORE INFORMATION
6 ATTIC
VENT
2
ROOFING
-METAL -TYP.RIDGE
-TYP.
EAVE
ROOF
EDGEROOF RAKE
-TYP.
EXIST. PROPERTY
LINE WALL
1 TYP.
2A
ROOFING
-"FLAT" -TYP.12 2122
3
EXTERIOR
PLASTER -TYP.
3
EXTERIOR
PLASTER -TYP.
10
STONE
-TYP.
5
WINDOWS -TYP.
11
DOWNSPOUTS /
GUTTER -TYP.
11
DOWNSPOUTS /
GUTTER -TYP.
9 MANUFACTURER'S SHROUD
PAINT TO MATCH ROOF COLOR
9 MANUFACTURER'S SHROUD
PAINT TO MATCH ROOF COLOR
D.S.
1 TYP.
8
TEMP.
TEMP.
10
STONE -TYP.
EAVE SOFFIT
AVG. N.G.: 65.02
6ATTIC
VENT
6 ATTIC
VENT
REAR ELEVATION
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
HIG
H
E
S
T
RID
G
E
79
.
3
0
EXIST. T.C.
GARAGE
DOOR
TEMP.
SLIDING
DOOR HD
SLIDING
DOOR THRESH.
EXIST.
GRADE
NEW 5FT HIGH POOL SECURITY FENCE
-TUBE STEEL o/3FT PLASTER WALL
UNDER SEPARATE PERMIT TYP.
NEW 5FT HIGH TUBE STEEL
POOL SECURITY FENCE
UNDER SEPARATE PERMIT TYP.
-SEE LANDSCAPE FOR MORE INFORMATION
-SEE LANDSCAPE FOR MORE INFORMATION
NEW 5FT HIGH TUBE STEEL
POOL SECURITY FENCE
UNDER SEPARATE PERMIT TYP.
-SEE LANDSCAPE FOR MORE INFORMATION
EXIST.
GRADE
EXIST. GRADEEXIST. GRADE
NEW 5FT HIGH POOL SECURITY FENCE
-TUBE STEEL o/3FT PLASTER WALL
UNDER SEPARATE PERMIT TYP.
-SEE LANDSCAPE FOR MORE INFORMATION
TEMP.TEMP.
PLANTER
RIDGE
-TYP.
EAVE
ROOF
EDGE 2
ROOFING
-METAL -TYP.
2A
ROOFING
-"FLAT" -TYP.
4
FASCIA -TYP.
4
FASCIA -TYP.
10
STONE -TYP.
5
WINDOWS -TYP.
5
EXTERIOR
DOORS -TYP.
5
EXTERIOR
DOORS -TYP.8 8
11
DOWNSPOUTS /
GUTTER -TYP.
DRIVEWAY -TYP.
9 MANUFACTURER'S SHROUD
PAINT TO MATCH ROOF COLOR
TEMP. TEMP. TEMP.
TEMP.
TEMP. TEMP. TEMP. TEMP. TEMP.
TEMP.
9 MANUFACTURER'S SHROUD
PAINT TO MATCH ROOF COLOR
10
STONE
EAVE SOFFIT
PAD (EXIST. F.F. -4")
AVG. N.G.: 65.02
RIGHT SIDE ELEVATION
PR
O
P
E
R
T
Y
L
I
N
E
RO
O
F
E
D
G
E
79
.
3
0
HIG
H
E
S
T
RID
G
E
79
.
3
0
HIG
H
E
S
T
RID
G
E
79
.
3
0
NEW 5FT HIGH TUBE STEEL
POOL SECURITY FENCE
UNDER SEPARATE PERMIT TYP.
NEW 5FT HIGH POOL SECURITY FENCE
4FT. GLASS o/ 1FT. BLOCK WALL.
UNDER SEPARATE PERMIT TYP.
-SEE LANDSCAPE FOR MORE INFORMATION
6 ATTIC
VENT 6 ATTIC
VENT
RIDGE
-TYP.ROOF RAKE
-TYP.
9
1 TYP.
NEW 5FT HIGH PROPERTY LINE WALL
EXTERIOR PLASTER o/CONC. BLOCK
UNDER SEPARATE PERMIT TYP.
2
ROOFING
-METAL -TYP.
12 2 12 2
122 122
3
EXTERIOR
PLASTER -TYP.
10
STONE5
WINDOWS -TYP.
11
DOWNSPOUTS /
GUTTER -TYP.
4
FASCIA -TYP.
MANUFACTURER'S SHROUD
PAINT TO MATCH ROOF COLOR
9 MANUFACTURER'S SHROUD
PAINT TO MATCH ROOF COLOR
TEMP.TEMP.
TEMP.
TEMP. TEMP. TEMP.
TEMP.
TEMP.
10
STONE -TYP.
10
STONE -TYP.
3
EXTERIOR
PLASTER -TYP.
EAVE
EAVE SOFFIT EAVE SOFFIT
10
STONE
TEMP.
TEMP. TEMP. TEMP.
TEMP. TEMP. TEMP.
PAD (EXIST. F.F. -4")
AVG. N.G.: 65.02
6 ATTIC
VENT
FRONT ELEVATION
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
4 5 2 7
PAD (EXIST. F.F. -4")
F.SLAB: 65.71
H.O.A. HEIGHT LIMIT -"FLAT" ROOF
H.O.A. HEIGHT LIMIT -RIDGE
PLATE & WNDW HD
(THIS LOCATION)
PA
R
A
P
E
T
79
.
3
0
EAVE
ROOF
EDGE
ROOF
EDGE
1 TYP.
2
ROOF -TYP.
123/8
3
EXTERIOR
PLASTER -TYP.
10
STONE -TYP.
5
WINDOWS -TYP.
ENTRY DOOR
(BEYOND)
11
DOWNSPOUTS /
GUTTER -TYP.
FRONT
GATE
TEMP. TEMP.
122
EAVE SOFFIT
AVG. N.G.: 65.02
TEMP.TEMP.TEMP.TEMP.TEMP.TEMP. TEMP.
MATERIAL SPECIFICATIONS
ROOFING -METAL
WHERE "ROOFING -METAL" IS INDICATED ON THE DRAWINGS PROVIDE:
SHEET METAL ROOFING SHALL COMPLY WITH CBC 1507.4. SHALL BE NOT
LESS THAN 30 GALVANIZED SHEET GAGE. UNLESS NOTED OTHERWISE
BERRIDGE MANUFACTURING CO.
1720 MAURY ST, HOUSTON, TX. 77026
Phone: (800) 231-8127
INSTALL PER MANUF. RECOMMENDATIONS
Z-LOCK SEAM WITH VINYL SEAL o/ UNDERLAYMENT
COLOR: SEE MATERIAL AND COLORS LEGEND, THIS SHEET
U.L. R12005 CLASS A, SYSTEM 8:
DECK: C-15/32 OR SPACED SHEATHING
UNDERLAYMENT: ONE OR MORE PLIES "VERSASHIELD UNDERLAYMENT",
MECHANICALLY FASTENED
SURFACING: COATED STEEL ROOFING PANELS, MECHANICALLY FASTENED
POLYGLAS POLYSTICK MTS (60 MIL)
OTHER APPROVALS: ARCHITECTURAL TESTING INC. REPORT NO.
79368.01-801-44
THERMAL AND CONTRACTION TEST
FACTORY MUTUAL RESEARCH INC.
REPORT NO. FMRC J.I. 2Y5AI.AM
UPLIFT TESTING
MECHANICALLY ATTACHED METAL ROOF PANELS.
INSTALL PER SMACNA STANDARDS. DECK (SHEATHING) SHALL BE DRY,
SMOOTH, AND COVERED BY 30 LB OF SATURATED ROOFING FELT. A
SMOOTH BUILDING PAPER SHALL BE APPLIED OVER THE FELT. WIDTH OF
PANS SHALL NOT EXCEED 20" WITH A MINIMUM 2" SEAM HEIGHT. PANS
SHALL BE INSTALLED WITH CLEATS NAILED ON 12 INCH CENTERS (OR AS
RECOMMENDED BY MANUFACTURER). EACH PAN SHALL BE LOCKED TO THE
ONE BELOW. PROVIDE SEALANT AT NAIL PENETRATIONS AND COVER FOR
DISSIMILAR METALS. FLAT SEAM ROOFING SHALL HAVE A MINIMUM SLOPE
PER SMACNA. SEAL (SOLDER) ALL JOINTS WHERE LESS THAN 3 INCHES IN
12 INCHES SLOPE.
WHERE "GARAGE DOOR" IS INDICATED ON THE DRAWINGS PROVIDE:
SEE ELEVATIONS (SHEET A-3) FOR STYLE.
SEE MATERIAL AND COLORS LEGEND, THIS SHEET.
GARAGE DOOR
WHERE "EXTERIOR PLASTER" IS INDICATED ON THE DRAWINGS PROVIDE:
EXTERIOR PLASTER o/METAL LATH o/BLDG PAPER
STEEL TROWEL FINISH
- UNLESS NOTED OTHERWISE.
PROVIDE CORROSION RESISTANT WEEP/DRIP SCREEDS, AND CORNER
BEADS AT ALL LOCATIONS PER PLASTER INSTITUTE STANDARDS.
PROVIDE MESH IN FINISH COAT WHERE STEEL TROWEL FINISH IS USED.
MERLEX INTEGRAL COLOR COAT
COLOR: SEE MATERIAL AND COLORS LEGEND, THIS SHEET.
AS SELECTED BY ARCHITECT AND APPROVED BY NEIGHBORHOOD
ASSOCIATION. PROVIDE COLOR SAMPLE PRIOR TO INSTALLATION.
EXTERIOR PLASTER
WHERE "WINDOWS" IS INDICATED ON THE DRAWINGS PROVIDE
WINDOWS AND DOORS:
FLEETWOOD -ALUMINUM DOORS AND WINDOWS
SEE MATERIAL AND COLORS LEGEND, THIS SHEET.
CONTACT:
INGRID EDGELL, ARCHITECT AND BUILDER REPRESENTATIVE
THE PELLETIER COMPANY
P 858-271-1750 F 858-271-1786
WINDOWS
WHERE "WOOD TRIM" IS INDICATED ON THE DRAWINGS PROVIDE:
STAIN GRADE
HEMLOCK OR EQUAL. CONTRACTOR TO PROVIDE ALTERNATE BID FOR
AFROMASIA.
SEE MATERIAL AND COLORS LEGEND, THIS SHEET.
WOOD TRIM
WHERE "ROOFING -"FLAT" IS INDICATED ON THE DRAWINGS PROVIDE:
CLASS-A FIRE RATED PVC SINGLE-PLY ROOFING BY: IB ROOFING SYSTEMS, INC
ICC ESR-2852
SYSTEM 7, COMBUSTIBLE SUBSTRATE, 1-1/2:12 MAX. SLOPE
2 LAYERS OF "IB FIRE SHEET FR-50
IB ROOFING PVC 80 MIL ASTM D-4434-12, TYPE III
IB ROOFING ADHESIVE AND FASTENERS/PLATES
25-YEAR LIMITED MATERIAL WARRANTY
CONTACT:
IB ROOFING SYSTEMS, INC
WWW.IBROOFING.COM
TECHNICAL@IBROOF.COM
TEL: (800) 426-1626
COLOR: SEE MATERIAL AND COLORS LEGEND, THIS SHEET
ROOFING -"FLAT"
1
WHERE "STONE" IS INDICATED ON THE DRAWINGS PROVIDE:
SEE MATERIAL AND COLORS LEGEND, THIS SHEET.
INSTALL PER MANUFACTURERS RECOMMENDATIONS.
INSTALL STONE ADHERERED VENEER OVER CEMENT PLASTER O/ METAL LATH
O/ WATERPROOF MEMBRANE. VENEER SHALL BE APPROX 16 POUNDS, 1.5"
THICK MAX.
EXTERIOR STONE IN SEISMIC DESIGN CATEGORY D (D2) SHALL NOT EXCEED
THE LIMITS OF TABLE 703.8.(2) AND SHALL NOT EXCEED 4 INCHES THICK.
STONE VENEER 1
1
2
3
4
5
6
8
9
10
11
12
13
14
15
NO. ITEM MATERIAL MANUFACTURER NAME
COLOR
NUMBER
COLOR COMMENTS
ROOF
WALLS -ACCENT
WALLS -STONE
FASCIA
WOOD TRIM
GARAGE DOOR
ENTRY DOOR
EXTERIOR DOORS
GUTTERS
FRONT GATES
DRIVEWAY
HARDSCAPE
WALLS -FIELD
7 WINDOWS
1A ROOF -"FLAT"
MATERIAL AND COLORS LEGEND FOR BUILDING AND HARDSCAPE
CORROSION RESIST. METAL
LIMESTONE
MATCH (1)
MATCH (6)
GLASS & METAL
MATCH (7)
MATCH (1)
GLASS & METAL
COLORED CONCRETE
LIMESTONE
EXTERIOR PLASTER
ALUMINUM
PVC SINGLE MEMBRANE
METAL SALES
....
U.S. STONE INDUSTRIES
....
....
CUSTOM
....
....
CUSTOM
DAVIS COLORS
....
MERLEX
IB ROOFING SYSTEMS
DARK BRONZE
COTTONWOOD
....
....
....
....
....
OUTBACK
MOCHA CREME
WHISPER
BRONZE ANODIZED
BROWN
....
....
....
....
....
....
....
....
....
677
....
3/4 P122-2
....
....
....
....
HONED / SPLIT FACE
....
....
....
....
....
....
AGGRAGATE FINISH
WIRE BRUSH FINISH
SMOOTH
....
....
WESTERN WINDOW
SYSTEMS
2A WALLS -FIELD2 EXTERIOR PLASTER MERLEX
DUNN EDWARDS LRV 8CAVERNOUS
6A METAL TRIM CORROSION RESIST. METAL ............
SMOOTH.
ALT: COLORED PLASTER
MATCH (7)
4533 PERHAM
MATCH (7)
EAVE SOFFIT STAIN GRADE WOOD BEHR TUGBOAT ST-141 HEMLOCK OR EQUAL
STAIN GRADE WOOD BEHR TUGBOAT ST-141 HEMLOCK OR EQUAL
CORROSION RESIST. METAL MATCH (1)
KEY NOTES -ELEVATIONS
MAINTAIN FINISH SLAB TO FINISH GRADE OR FINISH SURFACE MIN.
CLEARANCES PER CRC R317. SLOPE FINISH GRADE OR FINISH SURFACE
AWAY FROM BUILDING. SEE DETAIL
NEW METAL ROOFING o/30# FELT o/ROOF SHEATHING
-SEE MATERIAL & COLORS LEGEND, THIS SHEET
1
2
3
4
5
6
7
EXTERIOR PLASTER o/METAL LATH o/BUILDING PAPER
STUCCO STEEL TROWEL FINISH -TYP. SEE SPECIFICATIONS BELOW
2 LAYER GRADE D PAPER (FELT) o/PLYWOOD SHEAR WALLS.
FASCIA.
-SEE MATERIAL & COLORS LEGEND, THIS SHEET
DOORS AND WINDOWS -TYP.
-SEE MATERIAL & COLORS LEGEND, THIS SHEET
ATTIC VENTILATION -SEE ROOF PLAN
HANDRAIL +36" ABOVE ADJACENT SURFACE
PICKETS -MAX. SPACE 3-7/8" BETWEEN -NOT USED
8 GUARDRAIL +42" ABOVE ADJACENT SURFACE
PICKETS -MAX. SPACE 3-7/8" BETWEEN
9 MANUF CHIMNEY CAP - PAINT TO MATCH ROOFING
10 STONE -SEE MATERIAL & COLORS LEGEND, THIS SHEET. SEE DTLS:
11 CONNECT DOWNSPOUTS TO SUBDRAIN SYSTEM
-SEE CIVIL PLANS
GENERAL NOTES -ELEVATIONS
1. PROVIDE ADDRESS ON BUILDING PER N.B.M.C. 13.12.210
2. SEE ROOF PLAN SHEET FOR ROOF VENTILATION CALCULATIONS.
3B WOOD TRIM.
-SEE MATERIAL & COLORS LEGEND, THIS SHEET
MATERIAL CALLOUT
-SEE MATERIALS AND COLORS LEGEND -THIS SHEET
NEW "FLAT" ROOFING o/30# FELT o/ROOF SHEATHING
-SEE MATERIAL & COLORS LEGEND, THIS SHEET2A
..
.
.
..
.
.
4/28/17
1/4" - 1'-0"
EX
T
E
R
I
O
R
E
L
E
V
A
T
I
O
N
S
CO
R
O
N
A
D
E
L
M
A
R
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
1
7/13/2018 4:47:34 PM
2 x10 R .R .2x10 R.R.2 x 1 0 R.R.
12 2
2x10 R.J.'S
BUTLER'S PANTRYKITCHEN HALL OFFICE
PR
O
P
E
R
T
Y
L
I
N
E
121/4
DRAPE POCKET
TO
P
O
F
S
L
O
P
E
(A
T
T
H
I
S
S
E
C
T
I
O
N
)
122 122 12 1/2
1 13 21
56 6
8
8
11
18
19
20B
22
26
66
ELEVATOR
LAUNDRY 2 / STORAGE HALL COURTYARD GYMGAME ROOM
TROUGH
LAP POOL
DRAPE POCKET
3
44
7
9
11
17
17
27
6
6
SECTION A-A
KEY NOTES -SECTIONS
2x RAFTERS / ROOF JOISTS -SEE FRAMING PLAN
BEAM PER STRUCTURAL
1
2
3
4
5
6
7
2x4 CEILING JOISTS @ 16"o.c.
DOORS AND WINDOWS -SEE PLAN -TYPICAL
2x4 STUDS @ 16"o.c. (TYPICAL U.N.O.)
8 2x6 STUDS @ 16"o.c.
9 2x P.T.D.F. MUD SILL
10 FLOOR JOISTS @ 16"o.c. -SEE FRAMING PLAN
11 EXTERIOR PLASTER o/ METAL LATH o/ BUILDING PAPER
COLOR COAT. -SEE SPECIFICATIONS -SHT A-3
11A EXTERIOR WOOD SIDING o/ BUILDING PAPER
SEE SPECFICATIONS -SHT A-3
12 GUARD +42" ABOVE ADJACENT SURFACE
PICKETS -MAX. SPACE 3-7/8" BETWEEN
13 5/8" PLYWOOD ROOF SHEATHING
SEE TITLE 24 FOR RADIANT BARRIER -AS OCCURS.
14 1-1/8" T&G PLYWOOD SUBFLOOR
15 FLUSH BEAM -SEE FRAMING PLAN
16 LIGHTING -SEE PLAN
17
18 2x SOLID BLOCKING
PROVIDE 1 1
8" FLOOR SHEATHING UNLESS NOTED
OTHERWISE.
NOTE TO STRUCT. ENG'R
FOR SHEAR WALLS GREATER THAN 5FT LONG USE 6" LESS
THAN THE MEASURED LENGTH FOR CALCULATION
PURPOSES WHEREVER POSSIBLE.
STAIRS. SEE PLAN FOR RISE AND RUN
HANDRAIL - 34" TO 38" ABOVE NOSING
CONCRETE FOUNDATION AND FOOTINGS
-SEE FOUNDATION PLAN
CONCRETE SLAB w/ REINFORCING STEEL
o/ W/P MEMBRANE. SEE A-1 AND STRUCT. FOR SLAB INFO.
19 F.G. BATT. WALL INSULATION AT 2x6 WALLS. SEE TITLE 24.
20A F.G. BATT. FLOOR INSULATION. SEE TITLE 24.
21
22
23 5/8" TYPE "X" GYPSUM BOARD AT WALLS THROUGHOUT GARAGE TO HOUSE.
5/8" TYPE "X" GYPSUM BOARD AT CEILING. (PROVIDE 2 LAYERS 5/8" TYPE "X"
GYPSUM BOARD AT CEILING WHEN TRUSS JOISTS ARE USED.) -W/P GYPSUM
BOARD ENTIRE GARAGE WHERE TYPE "X" NOT REQUIRED BY CODE.
24 ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS,
UNDER-STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED
SIDE WITH 1/2-INCH (12.7 MM) GYPSUM BOARD. CRC R302.7
25 DECK: SEE "DECK MATERIAL" NOTE ON SHEET A-2.2. MAINTAIN 1 /4" PER
FOOT MINIMUM SLOPE. DRAIN TO GUTTER OR DECK DRAINS PER PLAN.
26 FIRE BLOCK @ 10'-0"o.c. HORIZONTAL AND VERTICAL, PER CRC R302.11
GENERAL NOTES -SECTIONS
1. PROVIDE FIRE BLOCKS @ 10'-0"o.c. BOTH VERTICALLY AND
HORIZONTALLY PER CRC R302.11
2. CONCEALED WALL SPACE NOT TO EXCEED 10 FEET INTERVAL
HORIZONTALLY. CRC R302.11
3. WHERE "LIGHT-WEIGHT CONC" IS CALLED OUT, INSTALL o/
WATERPROOF MEMBRANE o/ PLYWOOD SHEATHING.
ROOFING OVER WATERPROOF MEMBRANE SEE ROOF PLAN AND
ELEVATIONS
20B F.G. BATT. ROOF INSULATION. SEE TITLE 24.
MAINTAIN FINISH SLAB TO FINISH GRADE OR FINISH SURFACE MIN.
CLEARANCES PER CRC R317. SLOPE FINISH GRADE OR FINISH SURFACE
AWAY FROM BUILDING. SEE DETAIL
WATERPROOFING. INSTALL BELOW-GRADE WATERPROOF MEMBRANE PER
MANUFACTURER'S RECOMMENDATIONS. PROVIDE PROTECTION BOARD
FROM BACKFILL. INSTALL FRENCH DRAIN BEHIND RETAINING WALL PER
SOILS REPORT. SEE DETAIL:
27
SECTION B-B
2 x 10 R.R .2x10 R.R.2 x 1 0 R.R.
12 2
ENTRY
PR
O
P
E
R
T
Y
L
I
N
E
121/4
TO
P
O
F
S
L
O
P
E
(A
T
T
H
I
S
S
E
C
T
I
O
N
)
2x10 R.J.'S
DRAPE POCKET
LIVING
122122
E.G.
SKYLIGHT
1
13 21
5
1212
18
20B
6
6
GYMGAME ROOM
DRAPE POCKET
GYM BATHHALL GYM
TROUGH
LAP POOL
POOL EDG
E
65.13
4
7
9
17
17
26
27
6
6
SECTION C-C
2x 1 0 R.R.2x10 R.R.2 x10 R .R .
12 2
PR
O
P
E
R
T
Y
L
I
N
E
121/4
TO
P
O
F
S
L
O
P
E
(A
T
T
H
I
S
S
E
C
T
I
O
N
)
2x10 R.R.2x10 R.R.
DRAPE POCKET
HERS
2x10 R.J.
M. BEDROOM
122122
12 2
12 2
COVERED PATIO
E.G.
DRAPE POCKET
1 13
21
5
7
8
11
18
19
20B
22
26
6
6
BEDROOM 2
TROUGH
LAP POOL
GARAGE
FAU
2x6 C.J.
(HUNG FROM FLOOR ABOVE)FAU(HUNG FROM FLOOR ABOVE)
SLOPE
1%
4 9
23
25
27
SLOPE
1/2%
..
.
.
..
.
.
4/28/17
1/4" - 1'-0"
BU
I
L
D
I
N
G
S
E
C
T
I
O
N
S
CO
R
O
N
A
D
E
L
M
A
R
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
1
7/13/2018 4:49:16 PM
SECTION D-D
2x 1 0 R.R.2x10 R.R.2x 1 0 R .R.
HIS CLOSET
PR
O
P
E
R
T
Y
L
I
N
E
121/4
E.G.
TO
P
O
F
S
L
O
P
E
(A
T
T
H
I
S
S
E
C
T
I
O
N
)
2x10 R.R.
DRAPE POCKET
2x10 R.J.
122
122
12 2
COVERED PATIO
2x1 0 R .R.2x10 R.R.
M BATHM. BEDROOM
12 2 2x10 R.R.
1 131132121
5
56 8
9
11A
19
20B
26
6
6
12 2
122
11
SPA
GARAGE
2x6 C.J.
FAU(HUNG FROM FLOOR ABOVE)FAU(HUNG FROM FLOOR ABOVE)
SLOPE
1%
4 9
23
25
27
SLOPE
1/2%
EQUIP.
KEY NOTES -SECTIONS
2x RAFTERS / ROOF JOISTS -SEE FRAMING PLAN
BEAM PER STRUCTURAL
1
2
3
4
5
6
7
2x4 CEILING JOISTS @ 16"o.c.
DOORS AND WINDOWS -SEE PLAN -TYPICAL
2x4 STUDS @ 16"o.c. (TYPICAL U.N.O.)
8 2x6 STUDS @ 16"o.c.
9 2x P.T.D.F. MUD SILL
10 FLOOR JOISTS @ 16"o.c. -SEE FRAMING PLAN
11 EXTERIOR PLASTER o/ METAL LATH o/ BUILDING PAPER
COLOR COAT. -SEE SPECIFICATIONS -SHT A-3
11A EXTERIOR WOOD SIDING o/ BUILDING PAPER
SEE SPECFICATIONS -SHT A-3
12 GUARD +42" ABOVE ADJACENT SURFACE
PICKETS -MAX. SPACE 3-7/8" BETWEEN
13 5/8" PLYWOOD ROOF SHEATHING
SEE TITLE 24 FOR RADIANT BARRIER -AS OCCURS.
14 1-1/8" T&G PLYWOOD SUBFLOOR
15 FLUSH BEAM -SEE FRAMING PLAN
16 LIGHTING -SEE PLAN
17
18 2x SOLID BLOCKING
PROVIDE 1 1
8" FLOOR SHEATHING UNLESS NOTED
OTHERWISE.
NOTE TO STRUCT. ENG'R
FOR SHEAR WALLS GREATER THAN 5FT LONG USE 6" LESS
THAN THE MEASURED LENGTH FOR CALCULATION
PURPOSES WHEREVER POSSIBLE.
STAIRS. SEE PLAN FOR RISE AND RUN
HANDRAIL - 34" TO 38" ABOVE NOSING
CONCRETE FOUNDATION AND FOOTINGS
-SEE FOUNDATION PLAN
CONCRETE SLAB w/ REINFORCING STEEL
o/ W/P MEMBRANE. SEE A-1 AND STRUCT. FOR SLAB INFO.
19 F.G. BATT. WALL INSULATION AT 2x6 WALLS. SEE TITLE 24.
20A F.G. BATT. FLOOR INSULATION. SEE TITLE 24.
21
22
23 5/8" TYPE "X" GYPSUM BOARD AT WALLS THROUGHOUT GARAGE TO HOUSE.
5/8" TYPE "X" GYPSUM BOARD AT CEILING. (PROVIDE 2 LAYERS 5/8" TYPE "X"
GYPSUM BOARD AT CEILING WHEN TRUSS JOISTS ARE USED.) -W/P GYPSUM
BOARD ENTIRE GARAGE WHERE TYPE "X" NOT REQUIRED BY CODE.
24 ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS,
UNDER-STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED
SIDE WITH 1/2-INCH (12.7 MM) GYPSUM BOARD. CRC R302.7
25 DECK: SEE "DECK MATERIAL" NOTE ON SHEET A-2.2. MAINTAIN 1 /4" PER
FOOT MINIMUM SLOPE. DRAIN TO GUTTER OR DECK DRAINS PER PLAN.
26 FIRE BLOCK @ 10'-0"o.c. HORIZONTAL AND VERTICAL, PER CRC R302.11
GENERAL NOTES -SECTIONS
1. PROVIDE FIRE BLOCKS @ 10'-0"o.c. BOTH VERTICALLY AND
HORIZONTALLY PER CRC R302.11
2. CONCEALED WALL SPACE NOT TO EXCEED 10 FEET INTERVAL
HORIZONTALLY. CRC R302.11
3. WHERE "LIGHT-WEIGHT CONC" IS CALLED OUT, INSTALL o/
WATERPROOF MEMBRANE o/ PLYWOOD SHEATHING.
ROOFING OVER WATERPROOF MEMBRANE SEE ROOF PLAN AND
ELEVATIONS
20B F.G. BATT. ROOF INSULATION. SEE TITLE 24.
MAINTAIN FINISH SLAB TO FINISH GRADE OR FINISH SURFACE MIN.
CLEARANCES PER CRC R317. SLOPE FINISH GRADE OR FINISH SURFACE
AWAY FROM BUILDING. SEE DETAIL
WATERPROOFING. INSTALL BELOW-GRADE WATERPROOF MEMBRANE PER
MANUFACTURER'S RECOMMENDATIONS. PROVIDE PROTECTION BOARD
FROM BACKFILL. INSTALL FRENCH DRAIN BEHIND RETAINING WALL PER
SOILS REPORT. SEE DETAIL:
27
SECTION E-E
PR
O
P
E
R
T
Y
L
I
N
E
SE
T
B
A
C
K
F.SLAB: 65.71
WNDW HD
PLATE
F.SLAB: 50.78
(THIS LOCATION)
2 x 10 R.R .
122
HIS CLOSETBEDROOM 2 BATH 2
F.SLAB: 65.71
F.SLAB: 50.78
2x10 R.R.2x10 R.R.
BEDROOM 3
PR
O
P
E
R
T
Y
L
I
N
E
SE
T
B
A
C
K
ENTRY COURTYARD
DRAPE POCKETDRAPE POCKET
21
5
7
8
11A
11
19
20B
22
26
OFFICE
6 6
PAD (EXIST. F.F. -4")
AVG. N.G.: 65.02
WNDW HD
PLATE
CLG
GARAGETHEATERGYM GYM BATH
WNDW HD
PLATE
CLG
FAU
2x6 C.J.
(HUNG FROM FLOOR ABOVE)FAU(HUNG FROM FLOOR ABOVE)FAU(HUNG FROM FLOOR ABOVE)
44
8
9
9
23
23
26
2727
BRIDGE
2x10 R.J.'S
2 x10 R .R .2x10 R.R.
122
12 2
12 3/8
HERS
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
SE
T
B
A
C
K
H.O.A. HEIGHT LIMIT -SLOPED ROOF
H.O.A. HEIGHT LIMIT -FLAT ROOF
F.SLAB: 65.71
WNDW HD
PLATE (THIS LOCATION)
F.SLAB: 65.71
WNDW HD
PLATE
F.SLAB: 50.78
(THIS LOCATION)
HIG
H
E
S
T
RI
D
G
E
78
.
8
6
"F
L
A
T
"
R
O
O
F
76
.
3
6
BATH 3 HALL M. BATH
SECTION F-F
COURTYARD
12 3/8
LINEN
1 13 21
5
6 67
8
12
18
19
20B
22
12
26
6
6
PAD (EXIST. F.F. -4")
AVG. N.G.: 65.02
LOUNGE GARAGE
WNDW HD
PLATE
CLG
EQUIP.
FAU(HUNG FROM FLOOR ABOVE)FAU(HUNG FROM FLOOR ABOVE)FAU(HUNG FROM FLOOR ABOVE)
2x6 C.J.
4
4 99
232326
2727
..
.
.
..
.
.
4/28/17
1/4" - 1'-0"
BU
I
L
D
I
N
G
S
E
C
T
I
O
N
S
CO
R
O
N
A
D
E
L
M
A
R
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
7/13/2018 4:49:48 PM
2 x 10 R.R .2x10 R.R.2 x 10 R.R .2x10 R.R.
2x10 R.J.'S
DINING / LIVING
PR
O
P
E
R
T
Y
L
I
N
E
SE
T
B
A
C
K
F.SLAB: 65.71
WNDW HD
PLATE
F.SLAB: 50.78
(THIS LOCATION)
F.SLAB: 65.71
F.SLAB: 50.78
BUTLER'S PANTRY
123/8
SECTION G-G
122 12 2
122 12 2
M. BEDROOMPATIO
PR
O
P
E
R
T
Y
L
I
N
E
1 13 2121
8
11 12
18
19
19
20B
22 25
26
6
6
6
PAD (EXIST. F.F. -4")
AVG. N.G.: 65.02
WNDW HD
PLATE
CLG
WNDW HD
PLATE
CLG
LAUNDRY GARAGELOUNGE
4
4
5
8
9
17
23
27
27 6
KEY NOTES -SECTIONS
2x RAFTERS / ROOF JOISTS -SEE FRAMING PLAN
BEAM PER STRUCTURAL
1
2
3
4
5
6
7
2x4 CEILING JOISTS @ 16"o.c.
DOORS AND WINDOWS -SEE PLAN -TYPICAL
2x4 STUDS @ 16"o.c. (TYPICAL U.N.O.)
8 2x6 STUDS @ 16"o.c.
9 2x P.T.D.F. MUD SILL
10 FLOOR JOISTS @ 16"o.c. -SEE FRAMING PLAN
11 EXTERIOR PLASTER o/ METAL LATH o/ BUILDING PAPER
COLOR COAT. -SEE SPECIFICATIONS -SHT A-3
11A EXTERIOR WOOD SIDING o/ BUILDING PAPER
SEE SPECFICATIONS -SHT A-3
12 GUARD +42" ABOVE ADJACENT SURFACE
PICKETS -MAX. SPACE 3-7/8" BETWEEN
13 5/8" PLYWOOD ROOF SHEATHING
SEE TITLE 24 FOR RADIANT BARRIER -AS OCCURS.
14 1-1/8" T&G PLYWOOD SUBFLOOR
15 FLUSH BEAM -SEE FRAMING PLAN
16 LIGHTING -SEE PLAN
17
18 2x SOLID BLOCKING
PROVIDE 1 1
8" FLOOR SHEATHING UNLESS NOTED
OTHERWISE.
NOTE TO STRUCT. ENG'R
FOR SHEAR WALLS GREATER THAN 5FT LONG USE 6" LESS
THAN THE MEASURED LENGTH FOR CALCULATION
PURPOSES WHEREVER POSSIBLE.
STAIRS. SEE PLAN FOR RISE AND RUN
HANDRAIL - 34" TO 38" ABOVE NOSING
CONCRETE FOUNDATION AND FOOTINGS
-SEE FOUNDATION PLAN
CONCRETE SLAB w/ REINFORCING STEEL
o/ W/P MEMBRANE. SEE A-1 AND STRUCT. FOR SLAB INFO.
19 F.G. BATT. WALL INSULATION AT 2x6 WALLS. SEE TITLE 24.
20A F.G. BATT. FLOOR INSULATION. SEE TITLE 24.
21
22
23 5/8" TYPE "X" GYPSUM BOARD AT WALLS THROUGHOUT GARAGE TO HOUSE.
5/8" TYPE "X" GYPSUM BOARD AT CEILING. (PROVIDE 2 LAYERS 5/8" TYPE "X"
GYPSUM BOARD AT CEILING WHEN TRUSS JOISTS ARE USED.) -W/P GYPSUM
BOARD ENTIRE GARAGE WHERE TYPE "X" NOT REQUIRED BY CODE.
24 ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS,
UNDER-STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED
SIDE WITH 1/2-INCH (12.7 MM) GYPSUM BOARD. CRC R302.7
25 DECK: SEE "DECK MATERIAL" NOTE ON SHEET A-2.2. MAINTAIN 1 /4" PER
FOOT MINIMUM SLOPE. DRAIN TO GUTTER OR DECK DRAINS PER PLAN.
26 FIRE BLOCK @ 10'-0"o.c. HORIZONTAL AND VERTICAL, PER CRC R302.11
GENERAL NOTES -SECTIONS
1. PROVIDE FIRE BLOCKS @ 10'-0"o.c. BOTH VERTICALLY AND
HORIZONTALLY PER CRC R302.11
2. CONCEALED WALL SPACE NOT TO EXCEED 10 FEET INTERVAL
HORIZONTALLY. CRC R302.11
3. WHERE "LIGHT-WEIGHT CONC" IS CALLED OUT, INSTALL o/
WATERPROOF MEMBRANE o/ PLYWOOD SHEATHING.
ROOFING OVER WATERPROOF MEMBRANE SEE ROOF PLAN AND
ELEVATIONS
20B F.G. BATT. ROOF INSULATION. SEE TITLE 24.
MAINTAIN FINISH SLAB TO FINISH GRADE OR FINISH SURFACE MIN.
CLEARANCES PER CRC R317. SLOPE FINISH GRADE OR FINISH SURFACE
AWAY FROM BUILDING. SEE DETAIL
WATERPROOFING. INSTALL BELOW-GRADE WATERPROOF MEMBRANE PER
MANUFACTURER'S RECOMMENDATIONS. PROVIDE PROTECTION BOARD
FROM BACKFILL. INSTALL FRENCH DRAIN BEHIND RETAINING WALL PER
SOILS REPORT. SEE DETAIL:
27
SECTION H-H
2x10 R.R.
F.SLAB: 65.71
F.SLAB: 50.78
PR
O
P
E
R
T
Y
L
I
N
E
12 1/4
PR
O
P
E
R
T
Y
L
I
N
E
SE
T
B
A
C
K
F.SLAB: 50.78
LIVINGKITCHEN COVERED PATIO
DRAPE POCKET
1 1321
5
6
8
11
18
19
20B
25
PAD (EXIST. F.F. -4")
AVG. N.G.: 65.02
WNDW HD
PLATE
CLG
GAME ROOM
WNDW HD
CLG
GARAGE
4 4
5
99
23
23
26
27
27
COURTYARD ELEVATION 1
TEMP. TEMP.
F.SLAB: 65.71
WNDW HD
PLATE
F.SLAB: 50.78
WNDW HD
PLATE
CLG
(THIS LOCATION)
(THIS LOCATION)
COURTYARD ELEVATION 2
TEMP. TEMP. TEMP.
F.SLAB: 65.71
WNDW HD
PLATE
F.SLAB: 50.78
WNDW HD
PLATE
CLG
(THIS LOCATION)
COURTYARD ELEVATION 3 COURTYARD ELEVATION 4
TEMP.
F.SLAB: 65.71
WNDW HD
PLATE
F.SLAB: 50.78
WNDW HD
PLATE
CLG
(THIS LOCATION)
6"
MA
X
.
1'
-
0
"
W
1'
-
0
"
H
=
6
'
-
0
"
M
A
X
.
SO
L
I
D
G
R
O
U
T
A
L
L
C
E
L
L
S
NO
S
P
E
C
I
A
L
I
N
S
P
E
C
T
I
O
N
EQEQ
3"
CO
V
E
R
EQEQ
6"
1'
-
0
"
1'
-
0
"
W + 6"3"
CO
V
E
R
H
=
6
'
-
0
"
M
M
A
X
.
#4 @ 24" O.C.
VERT. BAR
6" CMU WALL
f'c = 1.500 PSI
#4 @ 32" O.C.
HORZ. BAR
3FENCE WALL ELEVATIONS SCALE 1/2"=1'-0"
NOTE:
ALL FOOTING IN LIQUEFACTION
ZONE SHALL BE 24" DEEP & SHALL
HAVE MIN. (2)-#5 TOP & BOTT.
(2)-#4 TOP & BOTT.
CONT.
#4 @ 32" O.C.
HORIZ. BAR
#4 @ 24" O.C. VERT.
SOLID GROUTED
ALL CELLS
6" CMU WALL
f'c = 1.500 PSI
(2)-#4 BARS
CONT.
H
4'-0"
5'-0"
6'-0"
W
1'-8"
2'-0"
2'-2"
NOTE
A
A
A
ALT.
FENCE
WALL3B
ALT.
FENCE
WALL3A
(2)-#4 TOP &
BOTT.CONT.
#4 @ 24" O.C.
w/ 6" HOOK
2% MIN.2% MIN.
2% MIN.2% MIN.
..
.
.
..
.
.
4/28/17
1/4" - 1'-0"
BU
I
L
D
I
N
G
S
E
C
T
I
O
N
S
CO
U
R
T
Y
A
R
D
E
L
E
V
A
T
I
O
N
S
CO
R
O
N
A
D
E
L
M
A
R
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
7/13/2018 5:10:08 PM
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
..
.
.
..
.
.
DATE
1/4" - 1'-0"
SQ
U
A
R
E
F
O
O
T
A
G
E
C
A
L
C
U
L
A
T
I
O
N
S
SEE "PROJECT DATA" ON SHEET A-1 FOR
SQUARE FOOTAGE CALCULATIONS.
LEGEND
HABITABLE AREA
AREA TOTALS
GARAGE AREA
DECK
ROOF DECK
(NOT APPLICABLE)
BASEMENT FLOOR
FIRST FLOOR
GARAGE
DECK
3,295 S.F.
5,007 S.F.
3,024 S.F.
1,086 S.F.
BASEMENT FLOOR
B_01
B_02
B_03
B_04
B_05
B_06
B_07
B_08
B_09
B_10
B_11
B_12
B_13
B_14
B_15
46.04 S.F.
599.93 S.F.
141.34 S.F.
294.04 S.F.
96.85 S.F.
329.38 S.F.
154.11 S.F.
139.82 S.F.
256.95 S.F.
151.64 S.F.
213.23 S.F..
22.67 S.F.
487.19 S.F.
347.03 S.F.
14.81 S.F.
3,295.03 S.F.
3,295 S.F.
GARAGE
G_01
G_02
G_03
G_04
G_05
G_06
G_07
G_08
40.42 S.F.
26.79 S.F.
38.91 S.F.
....
730.80 S.F.
1,182.37 S.F.
661.99 S.F.
342.92 S.F.
3,024.2 S.F.
3,024 S.F.
BASEMENT FLOOR
NOTE:
ANY DIMENSIONS PROVIDED ON THESE
SQUARE FOOTAGE CALCULATION SHEETS
SHALL BE USED FOR SQUARE FOOTAGE
CALCULATION PURPOSES ONLY.
40.42 S.F.
G_01
38.91 S.F.
G_03
26.79 S.F.
G_02
730.80 S.F.
G_05
1,182.37 S.F.
G_06 661.99 S.F.
G_07
342.92 S.F.
G_08
46.04 S.F.
B_01
599.93 S.F.
B_02 141.34 S.F.
B_03
139.82 S.F.
B_08
294.04 S.F.
B_04
329.38 S.F.
B_06
96.85 S.F.
B_05
154.11 S.F.
B_07
151.64 S.F.
B_10
256.95 S.F.
B_09 213.23 S.F.
B_11
22.67 S.F.
B_12
487.19 S.F.
B_13
347.03 S.F.
B_14
14.81 S.F.
B_15
FIRST FLOOR PLAN
1
1
7/13/2018 5:10:49 PM
WALL HUNG
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
..
.
.
..
.
.
DATE
1/4" - 1'-0"
SQ
U
A
R
E
F
O
O
T
A
G
E
C
A
L
C
U
L
A
T
I
O
N
S
BASEMENT FLOOR PLAN
FIRST FLOOR
F_01
F_02
F_03
F_04
F_05
F_06
F_07
F_08
F_09
F_10
F_11
F_12
F_13
F_14
F_15
F_16
F_17
F_18
F_19
F_20
F_21
F_22
F_23
F_24
F_25
F_26
F_27
F_28
F_29
F_30
F_31
6.68 S.F.
329.69 S.F.
326.86 S.F.
88.83 S.F.
138.67 S.F.
758.36 S.F.
90.12 S.F.
471.73 S.F.
18.33 S.F.
155.95 S.F.
296.84 S.F.
166.88 S.F.
1.10 S.F.
229.31 S.F.
16.06 S.F.
246.02 S.F.
366.27 S.F.
405.83 S.F.
80.47 S.F.
43.83 S.F.
269.62 S.F.
9.41 S.F.
4.62 S.F.
40.27 S.F.
66.15 S.F.
2.16 S.F.
99.75 S.F.
224.83 S.F.
27.13 S.F.
12.23 S.F.
13.29 S.F.
5007.29 S.F.
5,007 S.F.
FIRST FLOOR
6.68 S.F.
F_01
329.69 S.F.
F_02
326.07 S.F.
F_03
88.83 S.F.
F_04
34.50 S.F.
F_05
758.36 S.F.
F_06
269.62 S.F.
F_21
9.41 S.F.
F_22
43.83 S.F.
F_20
80.47 S.F.
F_19
405.83 S.F.
F_18
229.31 S.F.
F_14
366.27 S.F.
F_17
90.12 S.F.
F_07
155.95 S.F.
F_10
296.84 S.F.
F_11
166.88 S.F.
F_12
246.02 S.F.
F_16
471.73 S.F.
F_08
18.33 S.F.
F_09
1.10 S.F.
F_13 16.06 S.F.
F_15
DECK
D_01
D_02
D_03
D_04
D_05
D_06
D_07
D_08
D_09
D_10
D_11
D_12
D_13
D_14
D_15
D_16
D_17
.48 S.F.
3.29 S.F.
37.44 S.F.
18.60 S.F.
6.68 S.F.
83.83 S.F.
6.35 S.F.
58.10 S.F.
74.03 S.F.
42.66 S.F.
73.76 S.F.
257.83 S.F.
334.61 S.F.
36.27 S.F.
2.55 S.F.
20.31 S.F.
28.73 S.F.
1085.52 S.F.
1,086 S.F.
36.27 S.F.
D_14
2.55 S.F.
D_15
334.61 S.F.
D_13
20.31 S.F.
D_16
257.83 S.F.
D_12
74.03 S.F.
D_09 42.66 S.F.
D_10
73.76 S.F.
D_11
58.10 S.F.
D_08
83.83 S.F.
D_06
18.60 S.F.
D_04
37.44 S.F.
D_03
3.29 S.F.
D_02
.48 S.F.
D_01
6.35 S.F.
D_07
6.68 S.F.
D_05
4.62 S.F.
F_23
40.27 S.F.
F_24
66.15 S.F.
F_25
84 S.F.
F_27
224.83 S.F.
F_28
27.13 S.F.
F_29
13.29 S.F.
F_31
12.23 S.F.
F_30
28.73 S.F.
D_17
1
1
1
7/13/2018 4:52:36 PM
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
2
5
45
3
3
P
E
R
H
A
M
R
O
A
D
45
3
3
P
E
R
H
A
M
..
.
.
..
.
.
DATE
1/4" - 1'-0"
LO
T
C
E
V
E
R
A
G
E
C
A
L
C
U
L
A
T
I
O
N
S
ROOF PLAN
LEGEND
ROOF AREA
AREA TOTALS
SITE AREA 10,950.93 S.F.
BUILDING FOOTPRINT (AT EAVES) 6,310 S.F.
LOT COVERAGE (AT EAVES) 57.62%
ROOF
R_01
R_02
R_03
R_04
R_05
R_06
R_07
R_08
R_09
R_10
R_11
R_12
R_13
7.91 S.F.
3958.86 S.F.
27.13 S.F.
40.28 S.F.
4.63 S.F.
9.86 S.F.
284.46 S.F.
1511.06 S.F.
349.75 S.F.
61.55 S.F.
17.43 S.F.
7.32 S.F.
30.23 S.F.
6310.47 S.F.
6,310 S.F.
ROOF
NOTE:
ANY DIMENSIONS PROVIDED ON THESE
SQUARE FOOTAGE CALCULATION SHEETS
SHALL BE USED FOR SQUARE FOOTAGE
CALCULATION PURPOSES ONLY.
7.91 S.F.
R_01
3958.86 S.F.
R_02
27.13 S.F.
R_03
4.63 S.F.
R_05
40.28 S.F.
R_04
9.86 S.F.
R_06
284.46 S.F.
R_07
1511.06 S.F.
R_08
349.75 S.F.
R_09
61.55 S.F.
R_10 17.43 S.F.
R_11
7.32 S.F.
R_1230.23 S.F.
R_13
1
1
9/14/2017
28
Appendix B
CERTIFICATION OF LANDSCAPE DESIGN
I hereby certify that:
(1) I am a professional appropriately licensed in the State of California to provide professional landscape design services.
(2) The landscape design and water use calculations for the property located at
(provide street address or parcel number(s)) were prepared by me or under my supervision.
(3) The landscape design and water use calculations for the identified property comply with the requirements of the City of Water
Efficient Landscape Ordinance (Municipal Code Sections
) and the City of Guidelines for Implementation of the City of Water Efficient Landscape Ordinance.
(4) The information I have provided in this Certificate of Landscape Design is true and correct and is hereby submitted in compliance with the City of
Guidelines for Implementation of the City of Water Efficient Landscape
Ordinance.
Print Name Date
Signature License Number
Address
Telephone E-mail Address
Landscape Design Professional’s Stamp (If applicable)