HomeMy WebLinkAboutW_5402_SCITY OF NEWPORT BEACH
PUBLIC WORKS DEPARTMENT
VICINITY MAP
F
W
O
C
ALI
TY
CI
O F N E
N I A
R
A
H
C
RT
OP
B
E
REPAIR PLAN
SANDCASTLE DR / BUCK GULLY DR
GATE VALVE REPAIR AND PIPE ABANDONMENT
1 1
SAWCUT/DEMOLISH EXISTING FEATURE AT JOINT
DEMOLISH AND REMOVE EXISTING 8" GATE VALVE
DEMOLISH AND REMOVE EXISTING SPOOL
DEMOLISH AND REMOVE EXISTING 18" x 8" x 18" TEE
1
2
3
4
1.ALL EXISTING ITEMS NOT CALLED OUT TO BE DEMOLISHED, SHALL
BE PROTECTED IN PLACE, UNLESS OTHERWISE INDICATED.
2. DELIVER EQUIPMENT REMOVED ON DEMOLITION NOTES 2
THROUGH 4 TO CITY YARD. COORDINATE WITH CITY STAFF FOR
DELIVERY/LOCATION WITHIN CITY YARD.
3. ALL FLANGE BOLTS SHALL BE TYPE 316 SS COATED WITH
ANTI-SIEZE COMPOUND.
4. ALL DUCTILE IRON FITTINGS SHALL BE ENCASED IN POLYETHYLENE
WRAP PER AWWA STANDARD C105.
5. EXACT UNDERGROUND CONDITIONS ARE UNKNOWN. IF ANY
UNFORESEEN OR CONFLICTING EQUIPMENT, FITTINGS, PIPING, OR
SOIL CONDITIONS ARE ENCOUNTERED, HALT WORK AND CONTACT
THE CITY'S UTILITIES DEPARTMENT.
1
1
2
3
4
INSTALL 18" x 8" STEEL CONCENTRIC REDUCER
INSTALL 8" C-900 PVC MOA SPOOL PIECE
INSTALL 8" FORD ULTRA FLEX WIDE RANGE COUPLING, OR APPROVED
EQUAL, IN ACCORDANCE WITH THE STANDARD SPECIAL PROVISIONS. TYPE
316 SS NUTS AND BOLTS ON THE COUPLING REQUIRED.
INSTALL AVK 65 SERIES 8" POXFL RESILIENT WEDGE GATE VALVE
INSTALL AVK 65 SERIES 8" MJXFL RESILIENT WEDGE GATE VALVE
CAP ABANDONED 18" R.C.C.P. WITH CONCRETE
1
2
3
4
6
5
REPAIR OPTION 1: DOWNSTREAM PIPE IS STEEL
1" = 2'
DEMO PLAN
1" = 2'
EXISTING 18" STEEL
W.M. ZONE III PIPE
EXISTING 8" STEEL OR
A.C.P ZONE III PIPE
(VIF PIPE MATERIAL)
SA
N
D
C
A
S
T
L
E
D
R
SA
N
D
C
A
S
T
L
E
D
R
EXISTING
18" R.C.C.P.
ZONE III PIPE
BUCK
GULLY
DR.
BUCK
GULLY
DR.
2'
-
0
"
EXISTING 18" STEEL
W.M. ZONE III PIPE
EXISTING 8" STEEL
ZONE III PIPE
EXISTING
18" R.C.C.P.
ZONE III PIPE
PLAN ABOVE IS FROM CITY OF NEWPORT BEACH TRACT MAP
NO. 6634, SHEET 6. OTHER RELEVANT INFORMATION FROM
TRACT MAP NO. 6634 CAN BE FOUND ON SHEETS 3 AND 13.
EXISTING 8" GATE VALVE
EXISTING
18" x 8" x 18"
REDUCING TEE
BU
C
K
G
U
L
L
Y
DR
I
V
E
SANDCASTLE DR / BUCK GULLY DR
GATE VALVE REPAIR AND PIPE
ABANDONMENT
1'
-
0
"
REPAIR OPTION 2: DOWNSTREAM PIPE IS A.C.P.
1" = 2'
24
"
EXISTING 18" STEEL
W.M. ZONE III PIPE
EXISTING
18" R.C.C.P.
ZONE III PIPE
12
"
SA
N
D
C
A
S
T
L
E
D
R
BUCK
GULLY
DR.
BUTT-STRAP
JOINT
FLANGED JOINT
MECHANICAL JOINT
FLANGED JOINT
BUTT-STRAP
JOINT
18
"
SP
O
O
L
BUTT-STRAP
JOINT
EXISTING 8" A.C.P.
ZONE III PIPE
DE
M
O
A
S
N
E
C
E
S
S
A
R
Y
TO
F
I
T
N
E
W
E
Q
U
I
P
This option was used
W-5402-S
•
•
•
• •
CITY OF
COSTA MESA
PA.c1,1c
JOHN WAYNE
> AIRPORT if
~,(,:
i,,t<
0' O,p
CITY OF
IRVINE ~
Q PROJECT LOCATION
I•
• ·-
.-.,
NOT TO SCALE
-·
-..
. -=--t Ii~.'.~
-d_:ht.tJ " I.
: et-•.?'-• " • .
• • I . . .
• ·11:
!'i:C'l ,·-·J ,· .
I •
' .
,•
-, ~ . ~v -ii -
. ' '
_... .I
•
_1 '
: '.3 .;.G• , ''"t.n' • • .. '(, 'l!IJ
12
• .t ..
GU .LL.'r'·
PUBLIC WORKS DEPARTMENT
I I
\
' '
.•
------
' . . '
\!d~~-..
i ~
•
5
------
0
0
0
0
0
0
0
0
0
0
DEMOL TION NOTES
CONSTRUCTION NOTES
GENERAL NOTES
RECORD DRAWINGS
These Record Drav-.ings have been prepared based on information submitted, in part, by
others. While this information is believed to be reliable, City of Newport Beach is not
responsible to its accuracy, nor for errors or omissions which may have been incorporated
into the:se plans as a result
E
(I_
D -sj-
~
-sj-
~
00 N ---.... <O D
"' 3:
""CJ
~ D D
I ;;!-"' ~ " " .r: ~ 0
<( <
-"' u ::, m
""CJ
C: " " :;::, "' " u
""CJ
C:
" {/]
I / X
0
;3-
.r: u
" " m
~ L
0
(I_
3: " z
,----,------,-------------------,-----.----------,---------+-----------------------------1~
NO. DATE DESCRIPTION OF REVISIONS APPROVED
REVIEWED: ·c:
0 " C:
;3-
c: " "E
0 ..,,
1-------.-----+---------------------,----------1;3-DESIGNED: DRAWN: i"
DAJ DAJ ,__ _____ __, ill
CHECKED: DA TE: SHEET OF _3-00 m M •• ~----------------------------------------------------------------------~-~---~~----------------~---~-------~----~-~~~-------------------~------~u