HomeMy WebLinkAboutW_5402_SCITY OF NEWPORT BEACH PUBLIC WORKS DEPARTMENT VICINITY MAP F W O C ALI TY CI O F N E N I A R A H C RT OP B E REPAIR PLAN SANDCASTLE DR / BUCK GULLY DR GATE VALVE REPAIR AND PIPE ABANDONMENT 1 1 SAWCUT/DEMOLISH EXISTING FEATURE AT JOINT DEMOLISH AND REMOVE EXISTING 8" GATE VALVE DEMOLISH AND REMOVE EXISTING SPOOL DEMOLISH AND REMOVE EXISTING 18" x 8" x 18" TEE 1 2 3 4 1.ALL EXISTING ITEMS NOT CALLED OUT TO BE DEMOLISHED, SHALL BE PROTECTED IN PLACE, UNLESS OTHERWISE INDICATED. 2. DELIVER EQUIPMENT REMOVED ON DEMOLITION NOTES 2 THROUGH 4 TO CITY YARD. COORDINATE WITH CITY STAFF FOR DELIVERY/LOCATION WITHIN CITY YARD. 3. ALL FLANGE BOLTS SHALL BE TYPE 316 SS COATED WITH ANTI-SIEZE COMPOUND. 4. ALL DUCTILE IRON FITTINGS SHALL BE ENCASED IN POLYETHYLENE WRAP PER AWWA STANDARD C105. 5. EXACT UNDERGROUND CONDITIONS ARE UNKNOWN. IF ANY UNFORESEEN OR CONFLICTING EQUIPMENT, FITTINGS, PIPING, OR SOIL CONDITIONS ARE ENCOUNTERED, HALT WORK AND CONTACT THE CITY'S UTILITIES DEPARTMENT. 1 1 2 3 4 INSTALL 18" x 8" STEEL CONCENTRIC REDUCER INSTALL 8" C-900 PVC MOA SPOOL PIECE INSTALL 8" FORD ULTRA FLEX WIDE RANGE COUPLING, OR APPROVED EQUAL, IN ACCORDANCE WITH THE STANDARD SPECIAL PROVISIONS. TYPE 316 SS NUTS AND BOLTS ON THE COUPLING REQUIRED. INSTALL AVK 65 SERIES 8" POXFL RESILIENT WEDGE GATE VALVE INSTALL AVK 65 SERIES 8" MJXFL RESILIENT WEDGE GATE VALVE CAP ABANDONED 18" R.C.C.P. WITH CONCRETE 1 2 3 4 6 5 REPAIR OPTION 1: DOWNSTREAM PIPE IS STEEL 1" = 2' DEMO PLAN 1" = 2' EXISTING 18" STEEL W.M. ZONE III PIPE EXISTING 8" STEEL OR A.C.P ZONE III PIPE (VIF PIPE MATERIAL) SA N D C A S T L E D R SA N D C A S T L E D R EXISTING 18" R.C.C.P. ZONE III PIPE BUCK GULLY DR. BUCK GULLY DR. 2' - 0 " EXISTING 18" STEEL W.M. ZONE III PIPE EXISTING 8" STEEL ZONE III PIPE EXISTING 18" R.C.C.P. ZONE III PIPE PLAN ABOVE IS FROM CITY OF NEWPORT BEACH TRACT MAP NO. 6634, SHEET 6. OTHER RELEVANT INFORMATION FROM TRACT MAP NO. 6634 CAN BE FOUND ON SHEETS 3 AND 13. EXISTING 8" GATE VALVE EXISTING 18" x 8" x 18" REDUCING TEE BU C K G U L L Y DR I V E SANDCASTLE DR / BUCK GULLY DR GATE VALVE REPAIR AND PIPE ABANDONMENT 1' - 0 " REPAIR OPTION 2: DOWNSTREAM PIPE IS A.C.P. 1" = 2' 24 " EXISTING 18" STEEL W.M. ZONE III PIPE EXISTING 18" R.C.C.P. ZONE III PIPE 12 " SA N D C A S T L E D R BUCK GULLY DR. BUTT-STRAP JOINT FLANGED JOINT MECHANICAL JOINT FLANGED JOINT BUTT-STRAP JOINT 18 " SP O O L BUTT-STRAP JOINT EXISTING 8" A.C.P. ZONE III PIPE DE M O A S N E C E S S A R Y TO F I T N E W E Q U I P This option was used W-5402-S • • • • • CITY OF COSTA MESA PA.c1,1c JOHN WAYNE > AIRPORT if ~,(,: i,,t< 0' O,p CITY OF IRVINE ~ Q PROJECT LOCATION I• • ·- .-., NOT TO SCALE -· -.. . -=--t Ii~.'.~ -d_:ht.tJ " I. : et-•.?'-• " • . • • I . . . • ·11: !'i:C'l ,·-·J ,· . I • ' . ,• -, ~ . ~v -ii - . ' ' _... .I • _1 ' : '.3 .;.G• , ''"t.n' • • .. '(, 'l!IJ 12 • .t .. GU .LL.'r'· PUBLIC WORKS DEPARTMENT I I \ ' ' .• ------ ' . . ' \!d~~-.. i ~ • 5 ------ 0 0 0 0 0 0 0 0 0 0 DEMOL TION NOTES CONSTRUCTION NOTES GENERAL NOTES RECORD DRAWINGS These Record Drav-.ings have been prepared based on information submitted, in part, by others. While this information is believed to be reliable, City of Newport Beach is not responsible to its accuracy, nor for errors or omissions which may have been incorporated into the:se plans as a result E (I_ D -sj- ~ -sj- ~ 00 N ---.... <O D "' 3: ""CJ ~ D D I ;;!-"' ~ " " .r: ~ 0 <( < -"' u ::, m ""CJ C: " " :;::, "' " u ""CJ C: " {/] I / X 0 ;3- .r: u " " m ~ L 0 (I_ 3: " z ,----,------,-------------------,-----.----------,---------+-----------------------------1~ NO. DATE DESCRIPTION OF REVISIONS APPROVED REVIEWED: ·c: 0 " C: ;3- c: " "E 0 ..,, 1-------.-----+---------------------,----------1;3-DESIGNED: DRAWN: i" DAJ DAJ ,__ _____ __, ill CHECKED: DA TE: SHEET OF _3-00 m M •• ~----------------------------------------------------------------------~-~---~~----------------~---~-------~----~-~~~-------------------~------~u