Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
W_5338_S
, "- TAMURA WELL FACILITY SLATER 0 ~ <Il GARFIELD ELLIS Cl z '.I "' w z f-Cl f- (/) ct: V) <( -,; I --' (/) 0 ::, z <Il AVE C> <( ::, f-VJ YORKTOWN Cl' I y ADAMS 0 0 m HUNTINGTONINDIANAPOLIS AVE EACH ATLANTA AVE HAM LTDN AVE DOLPHIN AVE WELL FACILITY AVE AVE AVE VICTORIA Cl' 0 m !l: I ST Ir, MAC ARTHUR --' ~ ii' m VICINITY MAP NOT TO SCALE W 17TH ST w ~ f-~ PLAY PORT ,-..t.408lLE VILLAGE-w "' ~ '" t:: I "' NEWHALL ST PROJECT ~ u 8 SITE w ~ • :,, w ~ W 16TH ,□= ~ a~ s Newport Beach f-Cily Utilities =:J z w ~ u s ~ PRODUCTION PL ! ~ -;,; z w u s ~ z <( BLVD ::, ST " ' FARAD ST OHMS WAY / ~~ II :¾ ' ST 1 ~ ~ W 15TH LOCATION MAP NOT TO SCALE 16TH STREET PUMP STATION $!TE ADDRESS; 949 WEST 16TH STREET NEWPORT BEACH, CA 92663 LA ESTRELLA AVE EL SOL AV£. LA COLONIA 8 ~ "' s OCr WW DR PUBLIC WORKS DEPARTMENT 16TH STREET PUMP STATION AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS LA ESTRELLA AVE t;; I;; f-" z J~ ~g f-w f-" i ti t, tii C-5196 DATE: CTOR, R.C.E. 47961 APPROVED: ___ Pa~~ __ _.__._-_'itu'--_nvt,..../....;;.._ _______ _ DATE: LOCATION MAP NOT TO SCALE DOLPHIN AVENUE WELL FACILITY $!IE ADDRESS: 9649 DOLPHIN AVENUE FOUNTAIN VALLEY, CA 92708 DEPUTY PW DIRECTOR/ CITY ENGINEER, R.C.E. 44223 ti RAINBOW CIR ! t;; SJ\N CLEMENTE r ARNffi DR I;; )'EMBRANDT Dis In r-----J w , w -< Lok, 0 "' z View Pork s ;"' .rr ; ~ 1 "- EL RANCHO - ~ I;; ~ ~ s ~ " ;s ~ ROSE AVE z AVE MARIPOSA AVE J_ w w w 0 " "' 0 0 t;; "', WARNER AVE I(\ Or o:: (I) AVE I ( ~ J ~ ~ '-/----__________,~ u, ~t§ t;; g LA ESPERANZA f---AVE ~ 5 t'ri~ < E ~ -~~~~~~CA~Pl=L~~~~ ...__ ~ i t; ; t; lA ESTR£LIA AVE >- <.J j5 1 In □ g~1n I v'rr--~ LA STELLA EL SOL AVf_ ffi ~ ~ ■ AVE < ::!:, ----J ~ ~ 3_ ~ Ji~ f-~..--~, % O n.. STARFISH ~ LA COLONIA AVE ~=-I SLATER ~ l a:: AYE-AV.,. I;; -< ~ ,lit;; DOLPHIN AVE.;;_~ <J PROJECT EL VALL£ AVE ' i' !e-< I;; ~----J Foe atom I r < ~ ~-c.=i Volley Ill m,,, SITE In El BLANCO Pork I 1-~-~~---1 1-AVE~~ .. ----,_, I 5 EL LAGO AVE I I ~ ~~PUEBU. I I::!: glAVE ! !E..i I LOCATION MAP NOT TO SCALE TAMURA WELL FACILITY SITE ADDRESS: • 17399 MAGNOLIA STREET FOUNTAIN VALLEY, CA 92708 SHEET INDEX SHT NO. SHEET TITLE 1 TITLE SHEET, SHEET INDEX, GENERAL NOTES, VICINITY MAP AND LOCATION MAPS 2 3 4 5 6 NOTES, SYMBOLS AND ABBREVIATIONS 16TH STREET PUMP STATION DEMOLITION AND MODIFICATION PLANS 16TH STREET PUMP STATION DEMOLITION AND MODIFICATION SECTIONS DOLPHIN AVENUE WELL FACILITY DEMOLITION AND MODIFICATION PLANS TAMURA WELL FACILITY DEMOLITION AND MODIFICATION PLANS 7 DETAILS 8 9 10 11 12 13 STANDARD ELECTRICAL SYMBOLS AND ABBREVIATIONS 16TH STREET PUMP STATION ELECTRICAL PLAN DOLPHIN AVENUE AND TAMURA WELLS FACILITY PARTIAL ELECTRICAL PLAN 161H STREET PUMP STATION CONTROLS - 1 16TH STREET PUMP STATION CONTROLS - 2 DOLPHIN AVENUE AND TAMURA WELLS FACILITY CONTROLS -3 GENERAL NOTES 1. ALL WORK DETAILED ON THESE PLANS TO BE PERFORMED UNDER CONTRACT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE •sTANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION•, 2009 EDITION AND SUPPLEMENTS TO DATE, EXCEPT AS OTHERWISE STATED IN THE CITY'S STANDARD SPECIAL PROVISIONS, OR IN THIS CONTRACT'S SPECIAL PROVISIONS. 2. EXISTING UNDERGROUND UTILITIES ARE SHOWN AS PER AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD PRIOR TO BEGINNING CONSTRUCTION. 3. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR, DIMENSION, AND FINISH TO ADJOINING IMPROVEMENTS. 4. ALL CONCRETE SHALL BE CLASS 560-C-3250 W/ FIBERMESH 300 0 1.5 LBS. PER CY OR APPROVED EQUAL 5. ANY DISCREPANCY IN THE DRAWINGS OR SPECIFICATIONS SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER. FAILURE TO DO SO WILL PLACE RESPONSIBILITY OF THE CONTRACTOR FOR CORRECTION. 6. ANY WORK NOT INDICATED ON THE DRAWINGS BUT CALLED FOR IN THE SPECIFICATIONS, OR VICE-VERSA, SHALL BE FURNISHED AND PERFORMED AS THOUGH SPECIFICALLY INDICATED AND CALLED FOR IN BOTH. ANY WORK NOT INSTALLED ACCORDING TO DRAWINGS AND SPECIFICATIONS OR ORDINANCES AND LAWS SHALL BE REPLACED AT CONTRACTOR'S EXPENSE. 7. REMOVAL, ABANDONMENT OR TEMPORARY RELOCATION OF EXISTING PIPES OR UTILITIES SHALL BE SCHEDULED WITH THE CITY INSPECTOR TO AVOID UNNECESSARY DISRUPTION OF PUMP STATION OPERATIONS. 8. CONTRACTOR SHALL FIELD VERIFY AND ADJUST ELEVATIONS AS REQUIRED TO MAINTAIN DIMENSIONAL RELATIONSHIPS DEPICTED IN THE DRAWINGS. 9. THE CONTRACTOR SHALL NOTIFY THE CITY INSPECTOR AS SPECIFIED 72 HOURS IN ADVANCE OF MAKING ANY CONNECTION TO AN ACTIVE PIPELINE OR UTILITY SYSTEM, AND SHALL RECEIVE THE INSPECTOR'S CONSENT BEFORE PROCEEDING. 10. THE CONTRACTOR SHALL SCHEDULE THEIR WORK TO CONTINUOUSLY MAINTAIN PUMP STATION OPERATIONS AND SHALL NOT UNDULY RESTRICT PUMP ST AITON ACCESS OR CIRCULATION. 11. THE CONTRACTOR SHALL PROVIDE ADEQUATE SANITARY CONVENIENCES FOR THE USE OF ALL PERSONS AT THE CONSTRUCTION SITE OF THE WORK. SUCH CONVENIENCES SHALL INCLUDE CHEMICAL TOILETS OR WATER CLOSETS LOCATED AT APPROPRIATE LOCATIONS. AT COMPLETION OF THE WORK, ALL CONVENIENCES SHALL BE REMOVED AND THE SITE LEFT IN SANITARY CONDITION. 12. THE CONTRACTOR SHALL PROVIDE AT THEIR OWN COST ALL ELECTRICAL POWER NECESSARY FOR CONSTRUCTION, TESTING, GENERAL AND SECURITY LIGHTING AND ALL OTHER PURPOSES, WHETHER SUPPLIED THROUGH TEMORARY OR PERMANENT FACILITIES. 13. EXISTING PIPING EQUIPMENT AND STRUCTURES ARE SHOWN AS LIGHT-LINED OR SCREENED AND ARE NOTED AS BEING EXISTING. NEW PIPING, EQUIPMENT AND STRUCTURES ARE SHOWN ON THE DRAWINGS AS HEAVY-LINED. 14. THE WORDS ·INSTALL. AND ·coNSTRUCT" IN THE PLANS AND SPECIFICATIONS INDICATE THAT THE CONTRACTOR SHALL FURNISH THE SPECIFIED EQUIPMENT OR MATERIAL AND INSTALL OR CONSTRUCT THEM IN PLACE, COMPLETE AND OPERABLE, UNLESS OTHERWISE EXPLICITLY INDICATED THAT THE MATERIAL IS FURNISHED BY THE CITY. 15. THE CONTRACTOR SHALL REFURBISH/REHABILITATE/REINSTALL ALL FACILITIES DAMAGED OR DETRIMENTALL AFFECTED BY THE CONSTRUCTION OF THE IMPROVEMENTS SHOWN ON THESE PLANS OR THE CONTRACTOR'S ACTIVITIES. ~ D I V) 0 "' ..-" / o> ~ "D / 0 "' ..-" 0 <( u / 0 ~ 0 0 C o> "' ., 0 I <D 0 / "' "O 0 ::;; C .c Q_ 0 0 I 0 "' ..-" / .c C) -------116 m ~ 1-----------------------------------------------------...------------------------..--.... --,.-------,--=--=----=~--...... """"'"__,=.1..,=~--r-==~------r---------------------------10 DESIGNED: DRAWN: APPROVALRECOMMENDED: APPROVAL RECOMMENDED: REVIEWED: 16TH STREET PUMP STATION ~ C-5196 Underground Service Alert 1-800 227-2600 TWO WORKING DAYS BEFORE YOU DIG EMERGENCY TELEPHONE NUMBERS SOUlHERN CALIFORNIA GAS COMPANY SOUlHERN CALIFORNIA EDISON COMPANY AT&T m.EPHONE COMPANY CllY Of NEWPORT BEACH UTILITIES DIVISION ORANGE COUNTY SANITATION DISlRICT TIME WARNER CABLE COX Co.tMUNICA TIONS DAY (800) 624-8153 l800i 611-1911 800 332-1321 949 644-3011 714 962-2411 714) 542-6222 (949) 644-3717 DUDEK 31878 Camino Capistrano #200 San Juan Capistrano, CA 92675 949.450.2525 Fax 805.963.2074 NAH CS " CHECKED DATE: ,,,/ AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS 5, RJO 4/02/13 ~ g' A=~ TITLE SHEET, SHEET INDEX, GENERAL NOTES, -~ L .SINACORl,RCE 46214 lRISLEE,RCE 55329 VICINITY MAP AND LOCATION MAPS I MUNICIPAL OPERATIONS I ANT CITY ENGINEER SENIOR CIVIL ENGINEER ~· 1---------------------------lc DEPARTMENTDIRECTOR CITY OF NEWPORT BEACH W-5338-S ~ t-----t--------1 DATE: ~-3-/.3 DATE: ..<\ -3-(!> DATE:_~l.f,.._/4+-{f,....,Z,~--'f L3 PUBLIC WORKS DEPARTMENT SHEET 1 OF 13 / ..._ __________________ ....11.--------------------------------..&.---------------""------.;_-.,_ ___ ....... ____ ..._ ___________________________________________________ o.. 31878 Camino Capistrano #200 San Juan Capistrano, CA 92675 949.450.2525 Fax 805.963.2074 C-5196 TWO WORKING DAYS BEFORE YOU DIG Call: TOLL FREE W-5338-S 13 CITY OF NEWPORT BEACH PUBLIC WORKS DEPARTMENT 16TH STREET PUMP STATION AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS NOTES, SYMBOLS AND ABBREVIATIONS 2 DEMOLITION NOTES CONSTRUCTION NOTES DETAIL 1 SECTION A SECTION AND DETAIL NUMBERING SYSTEM 3 ͟͟ SYMBOLS -0-POWER POLE 8 SEWER CLEANOUT (S) SEWER MANHOLE @ STORM DRAIN MANHOLE l>()cl FIRE HYDRANT -WAlER MElER 1111 STREET LIGHT PULL BOX 1111 TRAFFIC SIGNAL PULL BOX :i>---o STREET LIGHT 0 WAlER VALVE ~ GUY WIRE " SURVEY MONUMENT p SIGN $ VAULT VENT e TREE 1111 IRRIGATION CONTROL VALVE lllll CABLE TV PULL BOX 0 CORING LOCATION (E) ELECTRICAL MANHOLE Ill ELECTRICAL PULL BOX ~//~/~ BUILDING ----EXISTING CONSTRUCTION ----PROPERTY LINE NEW CONSTRUCTION ---It---CENTERLINE ----S----SEWER LINE -----W-----WAlER LINE ---G---GAS LINE --E--ELECTRICAL LINE --T--lELEPHONE LINE -CATV-CABLEVISION LINE --SP--SPRINKLER SYSTEM -x-x-x-FENCE BLOCKWALL DESIGNED: Underground Service Alert NAH ~ DUDEK CHECKED: ~ .,, RJO ~~ No.063288 1-800 227-2600 ABBREVIATIONS (IN ADDITION TO GREENBOOK SECTION 1-3.2) AB AGGREGA lE BASE ARV AIR RELIEF VALVE ACP ASBESTOS CEMENT PIPE AC ASPHALT CONCRElE BC BEGIN CURVE BCR BEGIN CURVE RETURN eve BEGIN VERTICAL CURVE BU< BLOCK CATV CABLE TV Cl CAST IRON t CENlERLINE CNB CITY OF NEWPORT BEACH CL CLASS CLR CL.EAR C&G CURB AND GUTlER CY CUBIC YARD E EAST /ELECTRIC DTL DETAIL DTLS DETAILS EC END CURVE ECR END CURVE RETURN EVC END VERTICAL CURVE EXIST EXISTING FLG FLANGE FE FLANGED END FL FLOW LINE FM FORCE MAIN G GAS GV GATE VALVE GB GRADE BREAK GE GROOVED END IP&T IRON PIPE AND TAG LBS POUNDS LT LEFT MAX MAXIMUM MJ MECHANICAL JOINT MIN MINIMUM NG NA TUR AL GROUND N NORTH NTS NOT TO SCALE NO NUMBER 0G ORIGINAL GROUND PE PLAIN END PROP PROPOSED PB PULL BOX RCP REINFORCED CONCRElE PIPE RET RETAINING RT RIGHT SCH SCHEDULE sco SEWER CL.EANOUT SMH SEWER MANHOLE swr SIIIIIJlAL.I( s SOUTH SCE SOUTHERN CALIFORNIA EDISON SQ SQUARE STL SlEEL T lELEPHONE w WEST/WAlER W/ WITH DRAWN: cs DATE: 3/26/13 DATE BY DESCRIPTION REVISIONS (D REMOVE 350-HP MOTOR, FABRICATED PUMP DISCHARGE HEAD, AND 6-STAGE VERTICAL TURBINE PUMP ASSEMBLY (TYP OF 2) @ REMOVE SOLID STATE SOFT STARTER PER ELECTRICAL DWGS (TYP OF 2) @ REMOVE AIR/VAC VALVE ASSEMBLY AND REINSTALL PER CONSTRUCTION NOTES (TYP OF 2) @ REMOVE ORIFICE PLATE ASSEMBLY AND ASSOCIATED PILOTRY CD 300-HP, 1,770-RPM INVERTER DUTY VERTICAL TURBINE PUMP MOTOR (TYP OF 2) ® FABRICATED STEEL PUMP DISCHARGE HEAD (30 PUMP CAN X 12 DISCHARGE PIPE) (TYP OF 2) @ 3-STAGE VERICAL TURBINE PUMP ASSEMBLY (TYP OF 2) © VARIABLE FREQUENCY DRIVE PER ELECTRICAL DWGS (TYP OF 2) ® MODIFY CONCRETE HOUSEKEEPING PAD PER DTLS 1 AND 2 ON SHT 7 ® REINSTALL AIR/VAC VALVE ASSEMBLY (TYP OF 2) 0 INSTALL 12-INCH FLANGE FILLER (+/-1-INCH THICKNESS). CONTRACTOR TO DETERMINE THICKNESS ® INSTALL 16-INCH FLANGE FILLER (+/-1-INCH THICKNESS). CONTRACTOR TO DETERMINE THICKNESS ® COORDINATE WITH CITY OPERATIONS AND INSTALL CAP/PLUG ON PILOTRY CONNECTION (ORIFICE PLATE TUBING CONNECTION) AT CLA-VAL COMPONENTRY (1) A SECTION CUT ON A SHEET IS IDENTIFIED AS FOLLOWS: ~ DIRECTION OF VIEW ~SECTION LETTER 4 SHEET WHERE SECTION IS DETAILED (2) THE SECTION IS IDENTIFIED AS FOLLOWS: NOT TO SCALE e=SECTION LETTER SHEET ON WHICH SECTION WAS CUT (3) DETAILS ARE CROSS REFERENCED IN A SIMILAR MANNER TO THAT OF SECTIONS EXCEPT DETAILS ARE ASSIGNED NUMBERS RATHER THAN LETTERS. NOT TO SCALE e=DETAIL NUMBER ~ INDICATES THAT DETAIL OR SECTION IS SHOWN ON SAME SHEET AS CALLED OUT I REVIEWED: ~ IRIS LEE, RCE 65329 SENIOR CIVIL ENGINEER APP'D. I DATE: 4/02/13 I SHEET OF Q 0 D ~ sj-1 en V C ry w D / ci: 31878 Camino Capistrano #200 San Juan Capistrano, CA 92675 949.450.2525 Fax 805.963.2074 C-5196 TWO WORKING DAYS BEFORE YOU DIG Call: TOLL FREE W-5338-S 13 CITY OF NEWPORT BEACH PUBLIC WORKS DEPARTMENT 16TH STREET PUMP STATION AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS 16TH STREET PUMP STATION DEMOLITION AND MODIFICATION PLANS SHEET NOTES: GRAPHIC SCALE DEMOLITION PLAN MODIFICATION PLAN DEMOLITION NOTES: ͟͟ CONSTRUCTION NOTES: 3 G) REMOVE 350-HP MOTOR, FABRICATED PUMP DISCHARGE HEAD, AND 6-STAGE VERTICAL TURBINE PUMP ASSEMBLY (TYP OF 2) @ REMOVE SOLID STATE SOFT STARTER PER ELECTRICAL DWGS (TYP OF 2) @ REMOVE AIR/VAC VALVE ASSEMBLY AND REINSTALL PER CONSTRUCTION NOTES (TYP OF 2) 1 I l,...,i...,1--,a........ I I I I I ! ! ) ! ~ ! EXISTING BOO XISTING BOOSJER PUMP NO l PUMP NO 2 I I I , I Ud I I I ' I Ud ~ PUMP ROOM SCALE: 1/4"=1'-0" EXISTING MCC 'C' I I I , I Uc:::J 300-HP, 1,770-RPM INVERTER DUTY VERTICAL TURBINE PUMP MOTOR (TYP OF 2) FABRICATED STEEL PUMP DISCHARGE HEAD (30 PUMP CAN X 12 DISCHARGE PIPE) (TYP OF 2) 3-STAGE VERICAL TURBINE PUMP ASSEMBLY (TYP OF 2) VARIABLE FREQUENCY DRIVE PER ELECTRICAL DWGS (TYP OF 2) MODIFY CONCRETE HOUSEKEEPING PAD PER DTLS 1 AND 2 ON SHT 7 REINSTALL AIR/VAC VALVE ASSEMBLY (TYP OF 2) I I I ' I L_.,i:: I EXISTING 12" STEEL PUMP DISCHARGE PIPING (TYP 5) EXISTING 24" STEEL WATER SUPPLY LINE (TYP) = □ I I I , I U:~ 1. ALL EXISTING ITEMS, CALLED OUT OR NOT, SHALL BE PROTECTED IN PLACE UNLESS OTHERWISE INDICATED. 2. DELIVER EQUIPMENT REMOVED ON DEMOLITION ITEMS G) AND @ TO CITY YARD. COORDINATE WITH CITY STAFF FOR DELIVERY/LOCATION WITHIN CITY YARD, OR DISPOSE AS DIRECTED BY THE ENGINEER. 3. VERIFY ALL DIMENSIONS, CLEARANCES, ETC. PRIOR TO SUBMISSION OF SHOP DRAWINGS AND EQUIPMENT PROCUREMENT. EXISTING MCC 'C' I ' I NEW BOOSJER PUMP NO 2 I I I ' I U:~ ~ PUMP ROOM I I I , I U:~ SCALE: 1/4"=1'-0" ~=•=~ I I I I I I I : I I EXISTING BciOSJER PUMP NO 4 i I I I I I I I I I ' I Ud J -td EXISTING 24" STEEL WATER SUPPLY LINE (TYP) EXISTING 12" STEEL PUMP DISCHARGE PIPING (TYP 5) 2' 4• SCALE: 1/4"=1'-0" .. ~ 0 D ~ " .------1 en .---------------.----------------T""-----....I-T:,DE"'s"'1G'°'NE"'o'": -...,,,oRA=w"°N:--r--r--r------------------,--~RE;:-V::;:IE:::wE"'o'": _____ "T ___________________ ..... _____ -; g_ Underground Service Alert -m i ~c_"_Ec_K_Eo_:..;..;.To_A_rE_:="-"i---1---1-------------------1---1 ~1----------------------------1/·~-1 RJO 3/26/13 ~ ~ IRIS LEE, RCE 65329 ~ SENIOR CIVIL ENGINEER o, w ~ 1-800 ~ 227-2600 DUDEK DATE BY DESCRIPTION APP'D. REVISIONS DATE: __ 4~f_02~/_13 __ _ 1--------1 5 L------------------------------...I.--------------...I.---------------...IL...------...IL----..L..-----L-----------------------....1L--------....1.-------------------,._ _____ ....,c.: SHEET OF 31878 Camino Capistrano #200 San Juan Capistrano, CA 92675 949.450.2525 Fax 805.963.2074 C-5196 TWO WORKING DAYS BEFORE YOU DIG Call: TOLL FREE W-5338-S 13 CITY OF NEWPORT BEACH PUBLIC WORKS DEPARTMENT 16TH STREET PUMP STATION AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS 16TH STREET PUMP STATION DEMOLITION AND MODIFICATION SECTIONS DEMOLITION NOTES: GRAPHIC SCALE DEMOLITION SECTION A MODIFICATION SECTION B ͟͟ CONSTRUCTION NOTES: SHEET NOTES: 4 3 3 EXISTING 12" SlEEL PUMP DISCHARGE PIPING EXISTING BOOSJEB PUMP NO l /pUMP NO 2 SCALE: 1/4"-1'-0" EXISTING CONCRETE SLAB EXISTING 30" DIA CML&:C SlEEL PUMP CAN EXISTING 24" SlEEL CML&:C WAlER PIPING BOTTOM OF CAN (EL 57.65) 0 EXISTING 12" SlEEL PUMP DISCHARGE PIPING NEW BOOSJEB PUMP NO l /pUMP NO 2 (i. EL 108.00) SEE SHEET NOlE 4 SCALE: 1/4"-1'-0" EXISTING CONCRElE SLAB EXISTING 30" DIA CML&:C SlEEL PUMP CAN EXISTING 24• SlEEL CML&:C WAlER PIPING BOTTOM OF CAN (EL 57.65) 0 (D REMOVE 350-HP MOTOR, FABRICAlED PUMP DISCHARGE HEAD, AND 6-STAGE VERTICAL TURBINE PUMP ASSEMBLY (TYP OF 2) 0 ® 0 300-HP, 1,770-RPM INVERlER DUTY VERTICAL TURBINE PUMP MOTOR (TYP OF 2) FABRICAlED SlEEL PUMP DISCHARGE HEAD (30 PUMP CAN X 12 DISCHARGE PIPE) (TYP OF 2) 3-STAGE VERICAL TURBINE PUMP ASSEMBLY (TYP OF 2) 1. ALL EXISTING llEMS, CALLED OUT OR NOT, SHALL BE PROlEClED IN PLACE UNLESS OTHERWISE INDICAlED. 2. DELIVER EQUIPMENT REMOVED ON DEMOLITION llEMS (D AND@ TO CITY YARD. COORDINAlE WITH CITY STAFF FOR DELIVERY/LOCATION WITHIN CITY YARD. 3. VERIFY ALL DIMENSIONS, CLEARANCES, ETC. PRIOR TO SUBMISSION OF SHOP DRAWINGS AND EQUIPMENT PROCUREMENT. 4. PROVIDE CLEARANCE FROM SUCTION BELL TO PUMP CAN PER PUMP MANUFACTURER'S WRITlEN RECOMMENDATIONS. 2' 4' 81 SCALE: 1/4"=1'-0" ~ 0 D ~ " ,-------11 en r--------------r---------------,,--------rD--E-SIG-N--ED-: -,-D--RA_W_N_: --r--.--,------------------r--rRE----VIE __ W __ ED_: --~---,.--------------------------! g_ Underground Service Alert NAH cs ~ Du DE K t-CHE-CKED:_RJOt-DAT----'-E:3/--'-26/13"1------l----l----------1-----1 ~-------------1 i 1-8QQ S~:11~~~~\f~CE~:~~ER ~ 227-2600 DATE BY DESCRIPTION APP'D. 1------------------...-------1: REVISIONS DATE: __ 4~/0_2~/_13___ 1-------t ~ SHEET OF ,,, ._ _______________________________________________________ .._ ______________________________________________________________ ._ ____ __.c: 31878 Camino Capistrano #200 San Juan Capistrano, CA 92675 949.450.2525 Fax 805.963.2074 C-5196 TWO WORKING DAYS BEFORE YOU DIG Call: TOLL FREE W-5338-S 13 CITY OF NEWPORT BEACH PUBLIC WORKS DEPARTMENT 16TH STREET PUMP STATION AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS DOLPHIN AVENUE WELL FACILITY DEMOLITION AND MODIFICATION PLANS GRAPHIC SCALE DEMOLITION PLAN MODIFICATION PLAN DEMOLITION NOTES: CONSTRUCTION NOTES: SHEET NOTES: 5 ~ DEEP WELL rr------ EXISTING 16" STEEL PIPE AND FITTINGS EXISTING 12" STEEL PIPE AND FITTINGS ~ SHALLOW WELL @ REMOVE SOLID STATE SOFT STARTER PER ELECTRICAL DWGS (TYP OF 2) @ REMOVE ORIFICE PLATE ASSEMBLY AND ASSOCIATED PILOTRY 0 ® VARIABLE FREQUENCY DRIVE PER ELECTRICAL DWGS (TYP OF 2) MODIFY CONCRETE HOUSEKEEPING PAD PER DTLS 1 AND 2 ON SHT 7 ------------+m. 0 © ® ~-~~~IS=Tl=N~G~1~8.~R~CP7 _________ _ --\ ------ \_EXISTING 18" RCP DRAIN PIPE INSTALL 12-INCH FLANGE FILLER (+/-1-INCH lHICKNESS). CONTRACTOR TO DETERMINE lHICKNl::SS INSTALL 16-INCH FLANGE FILLER (+/-1-INCH lHICKNESS). CONTRACTOR TO DETERMINE lHICKNl::SS DRAIN PIPE ~ DEEP WELL EXISTING 16" STEEL PIPE AND FITTINGS EXISTING 16" CML&:C DISCHARGE PIPE SCALE: 1/4"=1'-0" ~ ELECJRICAL EQUIPMENT ROOM. --\ ------ \_EXISTING 18" RCP DRAIN PIPE EXISTING 16" CML&:C DISCHARGE PIPE SCALE: 1/4"=1'-0" EXISTING 16" CML&:C DISCHARGE PIPE EXISTING 12" STEEL PIPE AND FITTINGS _,__ __ -------- ---, -------- EXISTING 16" CML&:C DISCHARGE PIPE \_EXISTING 18" RCP DRAIN PIPE ~ SHALLOW WELL COORDINATE WllH CITY OPERATIONS AND INSTALL CAP/PLUG ON PILOTRY CONNECTION (ORIFICE PLATE TUBING CONNECTION) AT CLA-VAL COMPONENlRY 1. ALL EXISTING ITEMS, CALLED OUT OR NOT, SHALL BE PROTECTED IN PLACE UNLESS OlHERWISE INDICATED. 2' 4' 81 SCALE: 1/4"=1'-0" ! 11 ~ 0 D ~ " ,-------11 en r--------------r---------------,,--------rD--E-SIG-N--ED-: -,-D--RA_W_N_: --r--.--,------------------r--rRE----VIE __ W __ ED_: --~---,.---------------------------! g_ Underground Service Alert NAH cs ~ Du DE K t-CHE-CKED:_RJOt-DAT---'-E:3/--'-26/13"1------l----l---------1-----1 ~-------------1 i 1-8QQ S~:11~~~~\f~CE~:~~ER ~ 227-2600 DATE BY DESCRIPTION APP'D. 1------------------...-------1: REVISIONS DATE: __ 4~/0_2~/_13___ 1-------t ~ SHEET OF ,,, ..._ _______________________________________________________ .._ ___________________________________________________________________ __.c: 31878 Camino Capistrano #200 San Juan Capistrano, CA 92675 949.450.2525 Fax 805.963.2074 C-5196 TWO WORKING DAYS BEFORE YOU DIG Call: TOLL FREE W-5338-S 13 CITY OF NEWPORT BEACH PUBLIC WORKS DEPARTMENT 16TH STREET PUMP STATION AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS TAMURA WELL FACILITY DEMOLITION AND MODIFICATION PLANS GRAPHIC SCALE DEMOLITION PLAN MODIFICATION PLAN DEMOLITION NOTES: CONSTRUCTION NOTES: SHEET NOTES: 6 EXlSil.t:iG. SHAU.OW WELL EXlSil.t:iG. '\~ '\ '\ ', ~ EXISTING 18" RCP / DRAIN PIPE SHAU.OW WELL '\~ '\ '\ ', ~ EXISTING 18" RCP / DRAIN PIPE EXISTING 12" STEEL PIPE AND FITTINGS EXISTING 12" STEEL PIPE AND FITTINGS ElilSil.l:ilz. ELECJRICAL EOUIPMENJ BQQM. EXISTING 16" CML&:C DISCHARGE PIPE SCALE: 1/4"=1'-0" EXlSil.t:iG. ELECJRICAL EOUIPMENJ BQQM. EXISTING 16" CML&:C DISCHARGE PIPE SCALE: 1/4"=1'-0" □ = ---------------------7 -- EXISTING 18" RCP DRAIN PIPE EXISTING 16" CML&:C DISCHARGE PIPE EXISTING 16" CML&:C DISCHARGE PIPE EXlSil.t:iG. DEEP WELl, '\ '\ '\ ~ EXISTING 18" RCP/ DRAIN PIPE EXlSil.t:iG. DEEP WELl, '\ '\ '\ ~ EXISTING 18" RCP/ DRAIN PIPE @ REMOVE SOLID STATE SOFT STARTER PER ELECTRICAL DWGS (TYP OF 2) @ REMOVE ORIFICE PLATE ASSEMBLY AND ASSOCIATED PILOTRY 0 ® 0 © ® VARIABLE FREQUENCY DRIVE PER ELECTRICAL DWGS (TYP OF 2) MODIFY CONCRETE HOUSEKEEPING PAD PER DTLS 1 AND 2 ON SHT 7 INSTALL 12-INCH FLANGE FILLER (+/-1-INCH THICKNESS). CONTRACTOR TO DETERMINE THICKNl::SS INSTALL 16-INCH FLANGE FILLER (+/-1-INCH THICKNESS). CONTRACTOR TO DETERMINE THICKNl::SS COORDINATE WITH CITY OPERATIONS AND INSTALL CAP/PLUG ON PILOTRY CONNECTION (ORIFICE PLATE TUBING CONNECTION) AT CLA-VAL COMPONENlRY 1. ALL EXISTING ITEMS, CALLED OUT OR NOT, SHALL BE PROTECTED IN PLACE UNLESS OTHERWISE INDICATED. 2' 4' 81 SCALE: 1/4"=1'-0" ! 11 ~ 0 D ~ " ,-------11 en r--------------r---------------,,--------rD--E-SIG-N--ED-: -,-D--RA_W_N_: --r--.--,------------------r--rRE----VIE __ W __ ED_: --~---,.---------------------------! g_ Underground Service Alert NAH cs ~ Du DE K t-CHE-CKED:_RJOt-DAT---'-E:3/--'-26/13"1------l----l---------1-----1 ~-------------1 i 1-8QQ S~:11~~~~\f~CE~:~~ER ~ 227-2600 DATE BY DESCRIPTION APP'D. 1------------------...-------1: REVISIONS DATE: __ 4~/0_2~/_13___ 1-------t ~ SHEET OF ,,, .... _______________________________________________________ .._ ___________________________________________________________________ __.c: 31878 Camino Capistrano #200 San Juan Capistrano, CA 92675 949.450.2525 Fax 805.963.2074 C-5196 TWO WORKING DAYS BEFORE YOU DIG Call: TOLL FREE W-5338-S 13 CITY OF NEWPORT BEACH PUBLIC WORKS DEPARTMENT 16TH STREET PUMP STATION AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS DETAILS 7 TYPICAL HOUSEKEEPING PAD PREPARATION DETAIL 1 TYPICAL HOUSEKEEPING EXTENSION DETAIL 2 NOTES: EXISTING CMU WALL <I NOT TO SCALE 4" <I .. <;I <I .... <I ... EXISTING CONCRETE HOUSEKEEPING PAD GRIND/SAWCUT TO REMOVE EXISTING CHAMFER AND CREATE A 1"X1" (MIN DIMENSIONS) KNOTCH EXISTING CMU WALL : ~ NEW WO_/: ~ #3 EPOXY COATED I I c!c CONTINUOUS I 1 ~~~TmAIL 1 I I 4" (MIN} PER NOTE 1 FIBER REINFORCED CONCRETE 1. MAINTAIN 4-INCH HORIZONTAL CLEARANCE FROM NEW VARIABLE FREQUENCY DRIVES TO TOP EDGE OF CHAMFER. 2. ROUGHEN EXISTING CONCRETE SURFACE AND APPLY EPOXY BONDING COMPOUND PRIOR TO POURING CONCRETE. ~ --------'<-----j• ..... "' •. 4q _.,d <I _4 ., .,, ,d . EXISTING CONCRETE PUMP STATION FLOOR () 4 <I 4 <I <I 4 EXISTING CONCRETE HOUSEKEEPING PAD NOT TO SCALE ... <I. _., .. PREPARE EXISTING SURFACE PER NOTE 2 (TYP) EXISTING CONCRETE PUMP STATION FLOOR #3 EPOXY DOWELS 0 12" O.C. (MIN 3" EMBED) ~ 0 D ~ "" ,-------11 en r--------------r---------------,,--------rD--E-SIG-N--ED-: -,-D--RA_W_N_: --r--.--,------------------r--rRE----VIE __ W __ ED_: ------,,---------------------------1 g_ Underground Service Alert NAH cs ~ Du DE K t-CHE-CKED:_RJOt-DAT----'-E:3/-'-26/13"1-------l-----l-------------1-------1 ~-------------1j 1-8QQ S~:11~~~~\f~CE~:~~ER ~ 227-2600 DATE BY DESCRIPTION APP'D. 1------------------...-------1: REVISIONS DATE: __ 4~/0_2~/_13___ 1-------t ;"_ SHEET OF ,,, ._ _______________________________________________________ .._ ______________________________________________________________ ._ _____ c.: CONDUIT SINGLE UNE SCHEMATIC CONDUIT SINGLE UNE SCHEMATIC DESCBIETION CONDUIT SINGLE LINE DESCBIETION fl.At:!. DIAGBAM fl.At:!. DIAGBAM DIAGBAM fl.At:!. DIAGBAM DIAGBAM 0 )50A :) CIRCUIT BREAKER. UPPER NUMBER IS TRIP RATING. e 0 KILOWATT METIER o 3P LOWER NUMBER IS NUMBER OF POLES 0 THREE POSITION SWITCH. MAINTAINED CONTACT ■ PS ~ PRESSURE SWITCH. CONTACT ACTION AS NOTIED -■ ......._. FUNCTION MAY VARY AS NOTIED ON DIAGRAMS. ON DRAWINGS CENTIER POSITION IS OFF ✓ TWO POSITION SWITCH. MAINTAINED CONTACT ~ I I I I I POWER TRANSFORMER. RATINGS AS NOTIED VVV\. _.._._. ■ FUNCTION MAY VARY AS NOTIED ON DIAGRAMS rrm ON DRAWINGS 0 DUPLEX RECEPTACLE. 20A, SPEC GRADE @) @) ■ MOMENTARY CONTACT PUSHBUTTON. FUNCTION w GROUNDING TYPE. UNLESS OTHERWISE NOTIED ...Li MAY VARY AS NOTIED ON DIAGRAMS ON DRAWINGS. ■ LOS MOMENTARY CONTACT PUSHBUTTON WITH PROVISION ◄ TIELEPHONE OUTILET $M ...Li FOR LOCKOUT. LOS JUNCTION BOX OR CONDUIT FITTING AS NOTIED OR ..L ..L D ~ ~ LOCKABLE DISCONNECT SWITCH. RATING AND 0 REQUIRED. - -DETAILS AS NOTIED ON DRAWINGS. (SHOWN WITH CONDUIT TURNING UP) - -- - 7; LEVEL SWITCH, CONTACT ACTION ■zs ■Ls rs-oJVU"Lo ~ LIMIT SWITCH. NORMALLY OPEN AS NOTIED ON DRAWINGS D r-7 r-7 □ ■zs CONTROL PANEL OR EQUIPMENT AS NOTED -LIMIT SWITCH. NORMALLY CLOSED L_...J L_...J ■Fs FLOW SWITCH, CONTACT ACTION AS NOTIED ON fiJ fiJ ~NOTO TIME DELAY RELAY CONTACT. ~ DRAWINGS OFF DELAY, NORMALLY OPEN, TIME OPEN TNcTC TIME DELAY RELAY CONTACT. $ FLUSH TOGGLE SWITCH, SINGLE POLE, SINGLE THROW OFF DELAY, NORMALLY CLOSED, TIME CLOSED $3 °J;:"!NOTC TIME DELAY RELAY CONTACT. FLUSH TOGGLE SWITCH, THREE WAY ON DELAY, NORMALLY OPEN, TIME CLOSED I DS ANcTO TIME DELAY RELAY CONTACT. I FLUORESCENT FIXTURE. SEE LIGHTING SCHEDULE. Ciiiil ON DELAY, NORMALLY CLOSED, TIME OPEN ■sov + l-0 LIGHTING FIXTURE, WALL MOUNTIED ---3 SOLENOID OPERATIED VALVE SEE LIGHTING SCHEDULE □ ~xx -<~ -<~ MH-MANHOLE PB-PULLBOX HH-HANDHOLE ~x MOTOR CONTROL CENTER DRAWOUT STABS OR AS NOTIED ON DRAWINGS PB ~ 2 MOTOR STARTIER WITH THERMAL OVERLOADS. -T-TIELEPHONE CONDUIT. SIZE AS NOTED -11-o"X,o-NUMBER INDICATES NEMA SIZE OL GROUNDING GRID OR GROUNDING CONDUCTOR .Jt MOTOR OVERLOAD CONTACT G SIZE AS REQUIRED OR AS NOTIED ON DRAWINGS ,@, 0 0 MOTOR, NUMBER INDICATIES HORSEPOWER ~ GROUND PIGTAIL. SIZE AS NOTIED ON DRAWINGS ~ INDICATING LIGHT, PUSH-TO-TIEST. LETTIER l INDICATIES COLOR. 0-EXOTHERMIC GROUND CONNECTION -R=RED B=BLUE G=GREEN A=AMBER W=WHITIE 0 CONTACTOR OR RELAY COIL LETTIER OR L NUMBER IS DESIGNATION -0 BOLTIED GROUND CONNECTION M NORMALLY CLOSED CONTACT. LETTIER OR .Jt NUMBER IS DESIGNATION 0 CONDUIT BENDING UP M NORMALLY OPEN CONTACT. LETTIER OR -II-NUMBER IS DESIGNATION • CONDUIT BENDING DOWN 9 RUNNING TIME METER, NON-RESETTABLE --UNDERGROUND OR CONCEALED CONDUIT, 1" MINIMUM 020A -b-FUSE, NUMBER INDICATES RATING EXPOSED CONDUIT, 3/4" MINIMUM. '"UJ..Ur CONTROL TRANSFORMER. RATING AS NOTIED ON nW HOMERUN CONDUIT WITH 3 CONDUCTORS, NEUTRAL ~ DRAWINGS OR AS REQUIRED BASED ON LOAD AND GROUND, CIRCUITS 1,3,5 PANEL PB1, NO SERVED. PB1 1,3,5 HASHMARKS INDICATIE 2 CONDUCTORS AND GROUND DESIGNED: DRAWN: Underground Service Alert ~ESSX~ JM CAD ,~. ~ CHECKED: DATE: DUDEK ~ORE: ,; ..MJI\._ MORAES/PHAM & ASSOCIATES JMM 4/02/13 ::J'~'<i 01~0 0 Call: TOLL FREE I o. ,,o~tni CONSULTING liLBCTRICAL le IIBCIIANICAL INGINDRS ZS ~.; 1-800 . /30 13 31878 Camino Capistrano #200 2131 PAl.tllAR AIRPORT RD .. SlE. 120 * ( ~ * San Juan Capistrano, CA 92675 ~~ 227-2600 CARLSBAD CA. 92011 (780) 431-11n J'_,, l°CTR\3/#; 949.450.2525 Fax 805.963.2074 "It or c~~1.f TWO WORKING DAYS BEFORE YOU DIG SCHEMATIC DESCBIETION DIAGBAM DRIVEN GROUND ROD/TIEST WELL 3/4" X 10' Cu CLAD STIEEL PANELBOARD OR AS NOTIED ON DRAWING LIQUIDTIGHT FLEXIBLE CONDUIT CONDUIT NUMBER ·xxx·. REFER TO CONDUIT SCHEDULE FOR DESCRIPTION MANUAL MOTOR STARTIER ..L -GROUND -- oJVU"Lo HEATIER, RATING AS NOTIED ON DRAWING □ HORN OR AUDIBLE SIGNAL fiJ PHASE □ TIERMINAL, INTIERNAL WIRING ■ TIERMINAL, FIELD WIRING INTRUSION (DOOR) SWITCH CONDUIT STUB OUT DISCONNECT SWITCH, F = FUSED NF = NON-FUSED XX = AMP RATING DATE BY DESCRIPTION REVISIONS STANDARD ABBREVIATIONS A AMPERES MH MANHOLE AF AMPERE FRAME MIN MINIMUM OR MINUTIE AFF ABOVE FINISHED FLOOR MLO MAIN LUGS ONLY AFG ABOVE FINISHED GRADE MOV MOTOR OPERATIED VALVE ACTUATOR AT AMPERE TRIP MSB MAIN SWITCHBOARD ATS AUTOMATIC TRANSFER SWITCH MTR MOTOR AUTO AUTOMATIC N NEUTRAL AWG AMERICAN WIRE GAUGE NA NON-AU TOMA TIC BC BARE COPPER NC NORMALLY CLOSED BKR BREAKER NCIO NORMALLY CLOSED, C CONDUIT INSTANTANEOUS OPEN CB CIRCUIT BREAKER NCTC NORMALLY CLOSED, CKT CIRCUIT TIME CLOSE c.o. CONDUIT ONLY NCTO NORMALLY CLOSE, CPT CONTROL POWER TRANSFORMER TIME OPEN CP CONTROL PANEL NEC NATIONAL ELECTRIC CODE CT CURRENT TRANSFORMER NIC NOT IN CONTRACT cu COPPER No NUMBER CR CONTROL RELAY NO NORMALLY OPEN DC DIRECT CURRENT NOIC NORMALLY OPEN, DISC DISCONNECT INSTANTANEOUS CLOSE DISC SW DISCONNECT SWITCH NOTC NORMALLY OPEN, DPDT DOUBLE POLE DOUBLE THROW TIME CLOSE DPST DOUBLE POLE SINGLE THROW NOTO NORMALLY OPEN, DWG DRAWING TIME OPEN DS DOOR SWITCH NP NAMEPLATE EL.ELEV ELEVATION NTS NOT TO SCALE EMT ELECTRICAL METAWC TUBING OL OVERLOAD EO ELECTRICALLY OPERA TIED PB PUSHBUTTON EXIST EXISTING PB PULLBOX FBO FURNISHED BY OWNER PC PHOTOCELL FLA FULL LOAD AMPS PCV PUMP CONTROL VALVE FLEX FLEXIBLE PMR POWER MONITOR RELAY FM FLOW METIER PNL PANEL FS FLOW SWITCH POS POSITION FT OR ' FEET OR FOOT PR PAIR FT FLOW TRANSMITTIER PRI PRIMARY FVNR FULL VOLTAGE NON REVERSING PS PRESSURE SWITCH GD GAS DETIECTORS PVC POLYVINYL CHLORIDE GFI GROUND FAULT INTIERRUPTIER PVC/RGS PVC JACKETED RIGID GFP GROUND FAULT PROTIECTION GALVANIZED STIEEL CONDUIT GND OR G GROUND RECEP RECEPTACLE HH HANDHOLE RCP REMOTIE CONTROL PANEL HOA HAND/OFF/AUTO RGS RIGID GALVANIZED STIEEL CONDUIT HTR HEATIER RTU REMOTE TIERMINAL UNIT IC INTIERRUPTING CURRENT RVAT REDUCED VOLTAGE AUTO TRANSFORMER IN OR " INCHES OR INCH SCE SOUTHERN CALIFORNIA EDISON JB OR J JUNCTION BOX, CONDULET OR SDGE SAN DIEGO GAS & ELECTRIC FITTING AS REQUIRED BY NEC. SEC SECONDARY UNLESS OTHERWISE NOTIED SEL SELECTOR KW KILOWATTS SP SPARE LCL LONG CONTINUOUS LOAD SPD SURGE PROTIECTION DEVICE LCP LOCAL CONTROL PANEL SPOT SINGLE POLE DOUBLE THROW LR LOCAL/REMOTIE SPST SINGLE POLE SINGLE THROW LOS LOCKOUT STOP STATION ss STAINLESS STIEEL LS LEVEL OR LIMIT SWITCH SSRV SOLID STATIE REDUCED VOLTAGE STARTIER LSIG LONG TIME, SHORT TIME, INSTANTANEOUS ST SHUNT TRIP AND GROUND FAULT ADJUSTMENTS STA STATION LT LIGHT STIL STIEEL LTG LIGHTING STIP SHIELDED TWISTED PAIR MCC MOTOR CONTROL CENTIER STR STARTER MCM THOUSAND CIRCULAR MILS STT SHIELDED TWISTIED TRIPLET MCP MOTOR CIRCUIT PROTIECTOR sv SOLENOID VALVE SW SWITCH SWBD SWITCHBOARD TIEL TIELEPHONE TIEMP TIEMPERA TURE TM TIELEMETRY TS TIEMPERA TURE SWITCH TYP TYPICAL UG UNDERGROUND UON UNLESS OTHERWISE NOTED VOLTS w WATTS W/ WITH W/0 WITHOUT WP WEATHERPROOF XFMR TRANSFORMER XP EXPLOSION PROOF ZS POSITION SWITCH OR LIMIT SWITCH 3W THREE WIRE 4W FOUR WIRE C-5196 REVIEWED: 16TH STREET PUMP STATION AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS ~ / STANDARD ELECTRICAL SYMBOLS IRIS LEE, RCE 65329 AND ABBREVIATIONS SENIOR CIVIL ENGINEER APP'D. CITY OF NEWPORT BEACH W-5338-S 4/02/13 DATE: PUBLIC WORKS DEPARTMENT SHEET 8 OF 13 ~ w el °' 0 ~ w z -::;- ~ :::;; m :::) U1 1": 0 0 / U1 [l_ f- Ul f- °' 0 [l_ 3 w z / N PUMp---+-i CONTROL PANEL 'CP-PS' @ 5 4 J ---a ---------- ---------- ---------- ---------- ---------- SWBD 'A' ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- J-BOX AT PUMP ---------- ---------- I I I I I I I I l __ ,J<:=:::i SWBD 'AA' -1--------+--I-+ - - ---------- ---------- ---------- ---------- I I I I I I I I l __ ,J<:=:::i ---------< -+--l I I I I I I I I I l __ ,J<:=:::i +--- - - - -1--- I I I I I I I I l __ ,J<:=:::i PARTIAL POWER PLAN GRAPHIC SCALE (FEET) SCALE: 3/8"=1'-0" 0 2 4 6 ~--i : I -----ll-- - - - ---+- I -+- ' i -F=~L EXISTING PUMPS AND MOTORS (TYP) I I I I I I I I l __ ,J<:=:::i -7 EXISTING NEW 108" NOTES: 0 EXISTING 120VAC CONDUIT. RETERMINATE PLC INTERFACE CONDUCTORS AT NEW VFD'S. ADD NEW PLC 1/0. 0 EXISTING FEEDERS. RETERMINATE CONDUCTORS AT NEW VFD. (2)3"C, (6)500 KCMIL + (2)#2G. 0 EXISTING CONTROL CONDUITS. RETERMINATE CONDUCTORS AT NEW VFD AND MOTORS. 3/4"C. -(7)#14 + 1-1/2"C. -(8)STT. 0 0 © 0 ® ® @ @ CORE DRILL WALL FOR NEW 2"C WITH (4)#18STP AND (4)#14 FROM 'CP-PS' INTO PUMP ROOM. USE 1 "C TO VFD #1 & #2 FOR VFD SPEED COMMAND AND FEEDBACK AND VALVE POSITION. SEAL WITH NON-SHRINK ELASTOMERIC GROUT. REMOVE EXISTING 350HP, 1194 RPM MOTORS AND REPLACE WITH 300HP, 1770 RPM MOTORS. ENLARGE HOUSEKEEPING PAD PER SHEET 7. REMOVE SAFTRONICS SSRV (TYP OF 2). TOSHIBA 18 PULSE W7 VFD (TYP OF 2). SPLICES, IF REQUIRED, ARE ALLOWED ONLY IN VFD ENCLOSURES. REMOVE SOLENOID VALVE CONDUCTORS BACK TO MOTOR JUNCTION BOX AND LABEL AS 'SPARES'. REMOVE ASSOCIATED FLEX CONDUIT. ADD (1) Al MODULE AND (1) AO MODULE TO EXISTING AB PLC. REFER TO ROCKWELL ELECTRIC, INC. DRAWINGS D278-L011-1196 ( 4/97). --2" (TYP) i-42" (TYP) -/: EXHAUST FAN X " ,. I'~ I'll ' ® P1 7 EXISTING CONDUITS (TYP) , 0 TOSHIBA 18P " " " VFD ~ " "' " "' ' - - I ® ~CONTROLS _v , I I P2 I P3 ~ I I I ' I '\___8. WIREWAY ELEVATION SCALE: 1/2"=1'-0" GRAPHIC SCALE (FEET) 2 4 SCALE: 1 /2" =1' -0" 6 7 I,..-FUTURE VFD (TYP OF 3) I I I EX )--SA -I {s ISTING FTRONICS RV TO REMAIN TYP OF 3) I I EX ISTING Jr 12' ' WIREWAY I I - N w ~ °' 0 ~ w z ~ ~ ::;; m :::, (/) r--------1 ~ C-5196 8 .. ---------------,~---------------.:.:.~~:.:,_,;_ _ _;_ __ ~==~"""T~=.--,r---------------r-r---i-----------------r-,~=~-----T--------:~:;-:-~:;::-::~~:;--;-:-;,::-~::-:;~:::-;------,~ DESIGNED: DRAWN: REVIEWED 16TH STREET PUMP STATION [)._ SCALE: 3/8"=1 '-0" Underground Service Alert Call: TOLL FREE 1-800 227-2600 ..MJI'\.._ MORAES/PHAM & ASSOCIATES CONSULTING IILBCTRICAL le KBCIIANICAL BNGINDRS 2131 PALOMAR AIRPORT RD.. S1E. 120 CARLSBAD CA. 92011 (780) 431-7tn JM CAD CHECKED: DATE: JMM 4/02/13 DUDEK 31878 Camino Capistrano #200 San Juan Capistrano, CA 92675 949.450.2525 Fax 805.963.2074 l---+-+-------------------1r----1 ~ DATE BY DESCRIPTION APP'D. IRIS LEE, RCE 65329 SENIOR CIVIL ENGINEER AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS t;i ./1--------------------------;_c ~ <D -16TH STREET PUMP STATION ELECTRICAL PLAN ~ 1------------------------------~--; 0 CITY OF NEWPORT BEACH ..._W_-_5_33_8_-_S--1 ~z DATE: __ 4_/_02_/_13___ r- TWOWORKING DAYS BEFORE YOU DIG REVISIONS PUBLIC WORKS DEPARTMENT SHEET g OF 13 ,,,, L_ _____ .1..,_....:.:.:._...:..:..:..:.::.::.... ___ .....L _________ L.._ ___ L..__..J....__....L.. _______ ....L... ___________ ...&...-___ ____._ _________ ......_ __ ___. N SHALLOW WELL FOR DOLPHIN DEEP WELL FOR DOLPHIN DEEP WELL FOR TAMURA SHALLOW WELL FOR ~T=A ... M~U~R~A~:_~~:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_-=i-... __ -_ -_ -_ -_ -_ -_ -_ -_ -_ ..:._ ~f -':..._ -_ -_ -..... -.,_ -_ -~:,"2._~~:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_:_=.=.=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-✓-~=-=-=-=-:.,:7 ~__; __ ____,.J~ ,,/4) r,------ ~~EXISTING 18" RCP DRAIN LINE EXISTING 16" STEEL PIPE AND FITTINGS I I L_J I I I I I I I I I r;a-~I I _______________ ~ ,,/4) ,---..,:::;_;:::-,_.qcg~.J..--1"C (2)#18STP + (3)#14 + (1)#18 STT ~---....___ r,- \..__ --~XI STING ELECTRICAL EQUIPMENT ROOM EXISTING 16" CML&C DISCHARGE LINE - 1 1/2"C 4)#18STP + (6)#14 + (2)#18 STT ~ I I /--\ f---4 I I I I I EXISTING 16" CML&C DISCHARGE LINE -x PARTIAL ELECTRICAL PLAN WALL SCALE: 1/4"=1'-0" 0 P1 EXISTING CONDUITS (TYP) DC CONTROL 0 MCP P2 8" WIREWAY A ELEVATION 10 SCALE: 1/2"=1'-0" NOTES: 0 ® 0 0 RAISE EXISTING JUNCTION BOX ON BOTH SIDES OF WALL. PROVIDE NEW CONDUIT PENETRATION AND PATCH EXISTING CONDUIT PENETRATION. EXISTING FEEDERS. RETERMINATIE CONDUCTORS AT NEW VFD. EXISTING CONTROL CONDUITS. RETERMINATE CONDUCTORS AT NEW VFD. SPLICES, IF REQUIRED, ARE ALLOWED ONLY IN VFD ENCLOSURES. TOSHIBA 18 PULSE W7 VFD (TYP OF 2). ENLARGE HOUSEKEEPING PAD PER SHEET 5. REMOVE SAFTRONICS SSRV (TYP OF 2). ADD (1) ANALOG INPUT MODULE AND (1) ANALOG OUTPUT MODULE TO EXISTING AB SLC PLC. REFER TO GL ENGINEERING CO., INC #HB028 REFERENCE DRAWINGS. ADD ONE SPARE CONTACT BLOCK TO EACH WELL HOA SWITCH TO CLOSE IN 'HAND' POSITION. ADD (2)#14 CONDUCTORS TO EACH VFD CONTROL CONDUIT. @ ADD MANUAL SPEED POT TO MCP. LOCATIE ADJACENT TO EACH HOA SWITCH. ADD (1)#18 STT FOR EACH VFD. @ ADD CONDUCTORS FROM MCP RESET RELAY TO EACH VFD IN EXISTING 120VAC CONDUITS. 0 0 EXISTING NEW GRAPHIC SCALE 2' 4' --a· --SCALE: 1/4"=1'-0" GRAPHIC SCALE (FEET) 2 4 SCALE: 1 /2" =1'-0" 6 ,.,, w ~ °' 0 ~ w z ~ ~ ::;; m :::, (/) .-------I ~ C-5196 8 .. ------------------------------""T"-------,~~~-,~~--,r--------------.-T"-,---------------"'T-TREVi'EWEii~---t-T-------:;-~~~~~-;;;-;;:-:i;-;;::;:;;-:;:;;:;:; ...... ----, ~[)._ DESIGNED: DRAWN: REVIEWED 16TH STREET PUMP STATION Underground Service Alert JM CAD Call: TOLL FREE 1-800 227-2600 ..MJI'\.._ MORAES/PHAM & ASSOCIATES CONSULTING IILBCTRICAL le KBCIIANICAL BNGINDRS 2131 PALOMAR AIRPORT RD.. S1E. 120 CARLSBAD CA. 92011 (780) 431-7tn CHECKED: DATE: JMM 4/02/13 DUDEK 31878 Camino Capistrano #200 San Juan Capistrano. CA 92675 949.450.2525 Fax 805.963.2074 I---+-+-----------------,-,~ DATE BY DESCRIPTION APP'D. IRIS LEE, RCE 65329 SENIOR CIVIL ENGINEER AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS t;i DOLPHIN AVENUE AND TAMURA WELLS FACILITY PARTIAL ELECTRICAL PLAN ~ 1----------------------...... ""'"'lo CITY OF NEWPORT BEACH ...... w_-_5_33_8_-_s""'"'i ~ L __________ L_.:.rw:o::_w:o::R:K:1N'.:G..'.'.D:Av::s~e'.:EF:o:RE:,~vo:u:,:o:1G:...__JL ________________ .L ______ ..J. ___ ...L. ___ ..J. ______________ ,L. __________ REV-1_s1o_Ns __________ L.. _______ L.. ___ P_u_B_L_1c_w_o_R_K_s_o_E_P_A_R_T_M_E_N_T ___ ....1,,_sH_EE-T-1_O.;....o_F _1_3_;; DATE: __ 4..c./_02....c/_13 __ _ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 480V L3 L2 L1 rrr ): } )--, MAIN CPT 120VAC FROM CPT FURNISHED WITH VFD CONTINUED FROM LEFT 0 H A -_MCP CR7 RR 48QV. __ 11 ~! II } CONTROL r~-l2_0_V ____ POWER 16 t---~1HL....l....1>---i.--...l...---..l....------+-----l,A::--...J CR1 -- 1 PLC I PUMP CALL RELAY (7) 33 t--< MOTOR TEMP TRIP FROM LN 62 MOTOR WINDING HIGH >-..... ----VF------+-------1 CR3 1---TEMPERA TURE RELAY (34,44) .... +---------------1 --17 j 3 1AUTO RUN 1 4 .__---1-011 COH)IE-( ___:: •• ~I ~I 1-....Lal-----...J L - - -J CR3 34 --• MOTOR WINDING HIGH TEMPERATURE LAMP 0 .__ ____________ ..,1......,L1 T1 o--+-----o-.... .__ _____________ ...L...nL2 -----------------1---aL3 T3o--+-----o--' VFD RUN STATUS TO LN ~ VFD FAIL STATUS TO LN ;ii_ NOTES H CR1 0 A RR s (RUN FWD) FREQUENCY© PRIORITY (RESET) COMMON RUN FAIL •••• • • • •• 1 1 □□□□ - OPERATOR PANEL MANUAL SPEED POT. 4-20MA REMOTE SPEED FROM PLC © 4-20MA SPEED FEEDBACK TO PLC © CONFIGURE THE DRIVE TO RESTART AUTOMATICALLY ON INSTANTANEOUS POWER FAIL. PROVIDE A PHASE SHIFTING AUTOTRANSFORMER FOR AN 18 PULSE DESIGN. (TOSHIBA W7). ALL ITEMS LOCATED AT VFD PANEL UNLESS OTHERWISE SHOWN. IN HAND POSITION SPEED CONTROL CHANGES FROM 4-20MA INPUT TO SPEED POT. ALL PUMP CONTROL PLC 1/0 IS EXISTING UNLESS NOTED. NEW PLC 1/0. 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 5 ~"4..1:Jr-,--- PLC 6 HAND MODE _J_ 7 -....o 00~)1~( --1■■ PLC 8 AUTO MODE RESET AT PUMP ,-7 MOTOR VIBRATION 16 I SW I 17 RR L -_J CR2 AT PIPING , -7 14 PSH I 15 L -_J TR1 RR -- --0 --0 RESET RELAY (9,ZLW MOTOR VIBRATION (28,42) MOTOR VIBRATION LAMP HIGH DISCHARGE PRESSURE ALARM TIMER (0-30 SEC) (30,43) HIGH DISCHARGE PRESSURE ALARM LAMP 35 36 37 38 39 40 41 42 43 44 45 46 47 --0 t--< MOTOR BEARING TRIP RR MOTOR BEARING HIGH FROM LN fil. >-..... ----IA-------4t---------lcR4 i---TEMPERATURE RELAY CR4 .,__< VFD RUN FROM LN 11 CR6 CR2 TR1 CR3 CR4 CR5 --0 --0 --0 1 ---7 HTR 2 I I L ___ J LOCATED AT PUMP CONTINUED ON NEXT SHEET ETM CR6 CR7 {36,45) 1---• MOTOR BEARING HIGH TEMPERATURE LAMP VFD FAIL --•LAMP 1---4 ELAPSED TIME METER PUMP RUN RELAY ( 41,69) PUMP RUN LAMP MOTOR SPACE HEATER COMMON FAIL RELAY (1.§..77,78) sj-w ~ °' 0 ~ w z ,:::;- ~ ::;; m :::J (/) r-Un;;;;~;;~;,;:;;,;-7r-------------,--::_:._:._:--r;;~-,-;;;;;;;--7r----------7rT1r------------,--~=~---~--------------_j~-~C2:--~5~1}9]6"J--1 ~ Underground Service Alert ,_ DESIGNED: DRAWN: ;,. JM CAD t------t--+-----------------1---1 REVIEWED 16TH STREET PUMP STATION K' Call: TOLL FREE 1-800 227-2600 TWO WORKING DAYS BEFORE YOU DIG .MJI'\._ MORAES/PHAM & ASSOCIATES CONSULTING IILBCTRICAL le KBCIIANICAL BNGINDRS 2131 PAl.(ljAR AIRPORT RD., S1E. 120 CARLSBAD CA. 92011 (780) 431-71n ~M/;;';' CHECKED: JMM DATE:4/02/13 D u D E K t--+-+--------------------L___J ~ / AND DOLPHl~6~:A;::E~A;~:;:~~;l:ROVEMENTS ~ I:~ l/l 31878 Camino Capistrano #200 IRIS LEE, RCE 65329 • (ecnnc.~ San Juan Capistrano, CA 92675 SENIOR CIVIL ENGINEER CONTROLS - 1 f- 949A 5o.2525 Fax 805.963.2074 DATE BY DESCRIPTION APP'D. i---------------------------1 ~ REVISIONS DATE: __ 4_,_/0_2...c_/_13 __ _ CITY OF NEWPORT BEACH PUBLIC WORKS DEPARTMENT W-5338-S ~ 1------,,,;,...-1 ~ SHEET 11 OF 13 / N 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 TEMPERATURE ' ,I CONTROL RELAY -L -1b -1s WINDING RTD1: ' -:1A ~ : 3S -3b - : 38 WINDING RTD3:► ' ---3A 2b -28 WINDING RTD2 -: 2A o-• : 4S -4b - -48 WINDING RTD4: ' ---4A -5b : 58 WINDING RTD5 ' --5A t►-■ -7S -7b 78 WINDING RTD7 --: 7A ---6b - -68 - BEARING RTD6: ' --6A t►-■ -8S -8b """1---g~5s BEARING RTD8' -- --;---g-98 - NOT USED -+---o-9A Underground Service Alert ~ORE -i:,,.. ,X§l "'i:.-, Call: TOLL FREE ~~--a ZS .m~ iii 1-800 ~ ·c 1>' 22?-2600 TWO WORKING DAYS BEFORE YOU DIG N - G--b rl : ~ , MOTOR TEMP TRIP TO LN 33 ... , r1: ... ' , BEARING TEMP TRIP TO LN 35 ~ , ..MJI'\._ MORAES/PHAM & ASSOCIATES CONSULTING IILBCTRICAL le KBCIIANICAL BNGINDRS 2131 PAl.tlMAR AIRPORT RD.. S1E. 120 CARLSBAD CA. 92011 (780) 431-71n 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 DESIGNED: CHECKED: ' / JM JMM ' ,I CR6 20' : I ■ PUMP RUN TO PLC 21 AT PIPING 1 ----7 11 I ' I VALVE I I LIMIT SW I 12 DISCHARGE © 0 I ■NC VALVE OPEN 6 I '-r" TO PLC I I 13 I o I ■ NO (CLOSED) L ____ J 'fR7 I I <iRZ Al DRAWN: CAD DATE: 4/02/13 22 ■ 24 PUMP FAIL TO PLC 24 DUDEK 31878 Camino Capistrano #200 San Juan Capistrano. CA 92675 949.450.2525 Fax 805.963.2074 ' l,1 REVIEWED: I---+-+-----------------,-, ~:;:::;z=::;~,;;f;~--__:) DATE BY DESCRIPTION REVISIONS APP'D. IRIS LEE, RCE 65329 SENIOR CIVIL ENGINEER DATE: __ 4..c./_02....c/_13 __ _ NOTES: SEE SHEET 11 FOR CONTROL NOTES ALL RTD'S LOCATED AT PUMP 16TH STREET PUMP STATION C-5196 AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS 16TH STREET PUMP STATION CONTROLS-2 CITY OF NEWPORT BEACH W-5338-S PUBLIC WORKS DEPARTMENT SHEET 12 OF 13 ::, [l_ ~ 0 ,;; t') ~ 0 N '--t') '--..- LO w I r- °' 0 [l_ :,:: w z / _J .,: r-r- ::, m ::::, (/) ~ 0 0 ~ / (/) [l_ r-(/) .c ~ <D ~ r- 0:: 0 [l_ :,:: w z / N . 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 480V L3 L2 L1 III ): } )--, MAIN CPT 480V ~ I II } CONTROL ~~-12_o_v ____ POWER -- 0 L----------+--oL1 T1 o--+----o-...... L-----------+--<>L2 L-----------+--oL3 T3o--+----o--' MCP, -1 s 0-+--i 33 34 35 36 37 M I 1CR2 I 0 (RUN FWD) 38 I MANUAL I FREQ PRIORITY R SPEED I 39 POT. I VFD RUN STATUS 0 (RESET) .__ ____ ---1--oCOMMON RUN _____ _J 4-20MA REMOTE SPEED FROM MCP 0 40 TO LN ~ 41 4-20MA SPEED FEEDBACK TO MCP VFD FAIL STATUS 0 42 FAIL TO LN ;il_ 0 0 0 0 0 © 0 © NOTES •••• ••••• I 1 □□□□ OPERATOR PANEL CONFIGURE THE DRIVE TO RESTART AU TOMA TICALL Y ON INSTANTANEOUS POWER FAIL. PROVIDE A PHASE SHIFTING AUTOTRANSFORMER FOR AN 18 PULSE DESIGN. ALL ITEMS LOCATED AT VFD PANEL UNLESS OTHERWISE SHOWN. FROM MCP NEW CONTACT BLOCK. IN HAND POSITION SPEED CONTROL CHANGES FROM 4-20MA INPUT TO SPEED POT. ALL PUMP CONTIROL 1/0 IS EXISTING UNLESS NOTED. NEW PLC 1/0. NEW. USE SPARE CONTACT IN MCP. 43 44 45 46 47 120VAC FROM CPT FURNISHED WITH VFD ...,__< MOTOR TEMP TRIP FROM LN 62 CR1 RR MOTOR WINDING HIGH 1------------1 CR1 --TEMPERATURE RELAY (34,42) 0 1---MOTOR WINDING HIGH TEMPERATURE LAMP 48 49 50 RR MOTOR BEARING HIGH 51 1-----+-------1 CR2 --TEMPERATURE RELAY (36,45) t--< MOTOR BEARING TRIP >-+-----I FROM LN fil CR2 --• MOTOR BEARING HIGH 52 0 TEMPERATURE LAMP RR VFD FAIL > I ...,___< FROM LN 12 >----------1 VFD FAIL RELAY 1----..... ------i CR3 t-----e (46) ,-----7 MCP I (RESET) I ---0 '-~ VFD FAIL --• LAMP © I 149 1RR 150 I RESET RELAY .,___ __________ ....,.... ----------1 RR --(9,JJ,~37) VFD RUN .,__< FROM LN 11 CR4 L _____ J ETM ELAPSED TIME 1--.. METER ....__ ..... PUMP RUN ----------1 CR4 --RELAY (41,69.~11) ---0 PUMP RUN ...,.__,. LAMP MOTOR SPACE ------•HEATER CRl-1---------------------; CR5 --COMMON FAIL RELAY -------i (1.§..73,73) CR2 CR3 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 TEMPERATURE CONTROL RELAY ._-------------+--oL Na--4----------◄ --1---01b --1---018 WINDING RTD1 AT PUMP (TYP.) ......_.::::r----<1::;:1-e-+---o1A e-+---03S -+---o3b --1---038 WINDING RTD3 --1---03A --1---02b ---02B WINDING RTD2 e-+---o2A -+---04s -+---o4b --1---048 BEARING RTD4 --1---04A --1---05b --1---05B BEARING RTD5 --1---05A --1---075 --1---07b --1---078 NOT USED ---o7A ---o6b --1---06B NOT USED --1---06A --1---05s --1---08b --1---088 NOT USED e-+---o8A --1---09b -+---098 NOT USED --1---09A Go----,,---, -- MOTOR TEMP TRIP TO LN 33 BEARING TEMP TRIP TO LN 35 CR4 69 I 70 CR4 71 72 CR5 73 I 74 24 ■ 83 24 9 ■ 12 PUMP RUN TO MCP PUMP RUN TO MCP PUMP FAIL TO MCP CR4 16 103 PUMP RUN TO MCP PUMP FAIL TO MCP ::, [)._ t!) w ~ °' 0 ~ w z -::::;- ~ ::;; m :::J (/) .--------1~ C-5196 8 .. ---------------------------------,r-------~==~"""T=.=.--,r---------------.-r--,-----------------r-il'REvi'EviiEii:'-----T--------:;-:;:;:;:;--;;:;:~~~:;--;;:;;;-~:;;~:;::;--'-----, ~[)._ DESIGNED: DRAWN: REVIEWED 16TH STREET PUMP STATION Underground Service Alert JM CAD Call: TOLL FREE 1-800 227-2600 ..MJI'\._ MORAES/PHAM & ASSOCIATES CONSULTING IILBCTRICAL le KBCIIANICAL BNGINDRS 2131 PAl.(ljAR AIRPORT RD., S1E. 120 CARLSBAD CA. 92011 (780) 431-71n CHECKED: DATE: JMM 4/02/13 DUDEK 31878 Camino Capistrano #200 San Juan Capistrano, CA 92675 949.450.2525 Fax 805.963.2074 t-----+-+------------------,----1 ~;:::;;~<.~--/ DATE BY DESCRIPTION APP'D. IRIS LEE, RCE 65329 SENIOR CIVIL ENGINEER AND DOLPHIN & TAMURA WATER WELLS IMPROVEMENTS t;i DOLPHIN AND TAMURA WELLS FACILITY CONTROLS-3 f- °' 1-----------------------..... '"""lo CITY OF NEWPORT BEACH L..._W_-_5_33_8_-_S""""' ~z DATE: __ 4_,_/_02---'-/_13___ r-L __________ _J _ _:TW::O~W:O:RK:l:NG:D:A::Y:S :BE:F:::O:RE:.Y:.:O:U~D=IG:...._L _________________ L ______ ..J ___ _JL ___ L ______________ .l.. __________ R_EVISI-ON_s __________ ,L _______ ..,L ____ P_U_B_L_IC_W_O_R_K_S_D_E_P_A_R_T_M_E_N_T ___ ....1_8_HE-ET_1..;3;....o_F1_3~;;