Loading...
HomeMy WebLinkAboutW_5217_S..... IA II E II: • \ ci i-------;-------+-"-'-'~ > " .: - CITY OF COSTA MESA VICTORIA r-, . . •-•~ 1 19 TH \ ~ L ·.___,. . - ·1 i . ~ -... 'f • (' ,, ;to ,, C VICINITY MAP ¼ 0 ,,. 1/2 3/• l --- -----GRAPHIC SCALI: IN MllES S T. st 0 C t "4 SYMBOL LEGEND ♦ POWER POLE Q MANHOLE t:f FIRE HYDRA~T □'8 METER BOX -@-VALVE f-POWER POLE ANCHOR .6, MONUMENT -x-x-FENCE BLOCK WALL 'e~ TREE f>),tJ SHRUBBERY .Jif..Jllf..i.JV ASPHALT PAVEMENT ~B BRICKWALK I·.;.·.::.· : : .:1 I, ·,. '·. •.,.-' ____ :..., L.L/..L,~ CONCRETE BUil DING E.XISTING CONSTRUCTION NEW CONSTRUCTION -·-i-CENTERLINE ----s-SEWER LINE -----w-WATER LINE --<r~ GAS LINE -£-POWER LINE -1"£L-TELEPHONE LINE -rv-CABLEVISION LINE -sP-SPRINKLER SYSTEM 3::,: STREET LIGHT Iv PROJECT LOCATION EMERGENCY TELEPHONE AGENCY SOUTHERN CALIFORNIA GAS COMPANY SOUTHERN CALIFORNIA EDISON COMPANY PACIFIC TELEPHONE COMPANY CITV OF NEWPORT BEACH (PUBLIC UTILITIES) COUNTY SANITATION DISTRICTS GROUP W CABLE OF CALIFORNIA COMMUNITY CABLEVISION UNDERGROUND SERVICE ALERT N. •o • U C I ............ .. IC VIE ORIAL All I-: 1 • ""1'--.!!:!I"-,___ \ • I _.,. _..J .;J_,, -. 0 • ·1 l I .... \_ . ,. ....... ' )-~ • ,. . ., CITY NEWPORT PUBLIC WORKS OF BEACH DEPARTMENT JAMBOREE ROAD WATER VALVE REPLACEMENT • I I I c... );To ~ tJJ I I I I .., C a, ,, •. APPROVED~-~-~~~~~~~~-DATE-'-'11Tf~=o+/,~1 __ DEPUT U. ES DIRECTOR ~ ' I 1/ ef: ' • NUMBERS NUMBER 634-0251 895-0221 551-7736 644-3011 962-2411 EXT. 222 642-3260 720-2056 1-800-422·4133 R.C.~ 387 • I NAME . . PETE ANTISTA 5"--· ~-1-x --~~ ,'!.. / ~ / / I I \ , / -------- " \ • r'1 ,,, ,,, >< X x-u; -(/) "' --t ::! --t -z -Z Z Cl Cl : tJ\= "' o, o,,e :e ~~ ~ --t :0 r'1 ,,, :,:, :,:, .. CONSTRUCTION NOTES (D REMOVE 6' OF 16' A.C .. PIPE, CL. 200 ® INSTALL TWO 16" TRANSITION COUPLINGS (A.C. RB1D.I.P CLASS !12) @ INSTALL CLASS 52 0.1.P. -© INSTALL 1ft' MECHANICAL JOINT BfV WITH MJ RETAINER GLANOS GENERAL NOTES & THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THE :~~fcM=s~~Nt~ oi~o"rnR~~:i.l c~,i~A~t~~A:B r5J:NDARO "ST"IWDARD S~/FICJ1TIONS f"OR PUSL/r. WORKS CONSTRUCTION',' 1991 EDITION II SUPPLEMENTS. £ EXISTING UNDERGROUND VTILITIES ARE SHOWN PER AVAILABLE RECC>Rtk,. THE CONTRAC:rOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION ANO ELEVATION IN .THE FIELD PRIOR TO BEGINNING CONSTRUCTION OF THE NEW FACILITIES. & CURS DATA REFERS TO FACE OF CURB. ffi OUCTILE IRON PIPE SHALL BE CLASS 52 ANO SHALL HAVE AN 8mll LOOSE POLYETHYLENE ENCASEMENT AS SECTION 207-9.62. OF Tt£ STANDARD SPECIFICATIONS. & THE CONTRACTOR SHALL NOTIFY THE FIRE DEPARTMENT 48 HOURS IN AC:WANCE OF SHUTTING OFF A~ FIRE HYDRANTS AT 644-3106. & THE FIRE DEPARTMENT SHALL BE NOTIFIED 48 HOURS IN ADIIANCE OF. ALL LANE CLOSURES. & ALL BOLTED ANO THREADED FASTENERS SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA ANO SHALL CONFORM TO THE MINIMUM REQUIREMENTS FOR STRENGTH, MATERIAL CONSTRJCTION AND DIMENSION /IS ESTABLISHED BY THE ASTM ANO THE ANSI SPECIFICATIONS. ALL FASTENERS SHALL BE ACCOMPANIED BY WRITTEN CERTIFICATION FROM THE MANUFACTURER STATING COMPLIANCE WITH THE APPROPRIATE SllEOFICATIONS. w-5217 -s SHT. r OF I . I I I _,,----=---=--..