Loading...
HomeMy WebLinkAboutT_5200_SNOTES l. THE-ELECTRICAL WORK AND EQUIPMENT SHALL CONFORM TO THIS PLAN, THE CALIFORNIA STANDARD PLANS, DATED MARCH 1977, AND STANDCIRD SPECIF!CATIONS DATED JAN. 1978, AND THE SPECIAL PROVISIONS FOR THIS PROJ::CT. 2. ALL CONDUIT SHALL BE MIN. 2-INCH UNLESS NOTED OTHERWISE HEREOII. 3. INDUCTIVE LOOPS SHALL BE 5'X6' WITH 10'SPACING IN THE DIRECTION OF TRAVEL AND SHALL BE POSITIONED IN THE FIE.LO AS DIRECTED BY THE "TRAFFIC ENGINEER. LOCATE LOOPS 6" BACK OF LIMIT LINE. QUEUE DETECTORS ARE 5'X 5'. 4. ALL PULL BOXES SHALL BE No. 5 UNLESS NOTED OTHERWISE. 5. INSTALL INTERNALLY ILLUMlNATED STREET NAME SIGN. REFER TO POLE SCHEDULE,SPECIAL PROVISIONS AND CITY STD. DRAWING No. STD.-911-L. 6. STRIPING AND SIGNING, EXCEPT AS NOTED IN 5 ABOVE, SHALL BE DONE BY OTHERS. 7. ALL SALVAGED MATERIALS AND EQUIPMENT SHALL BE MAINTENANCE YARD, 592 SUPERIOR AVE. DELIVERED TO CITY OF NEWPORT BEACH 8. ABANDON EXISTING SIGNAL CONDUIT RUN. 9. REMOVE ALL EXISTING CONDUCTORS, EXCEPT INTERCONNECT AND PRE-EMPT AS NOTED HEREON, AND INSTALL NEW THROUGHOUT. 10. ALL SIGNAL SECTIONS SHALL BE 12-INCH UNLESS OTHERWISE NOTED HEREON. 11. SEE DETAIL (BELOW RIGHT) FOR THE PROGRAMMED VISIBILITY LEFT-TURN SIGNAL ON POLES @ &(z) . 12. REPLACE L.UMINAIRES ON. P,OLES@ &@ WITH 250W.H.P.S.V.(SEE SPECIAL ffiOVISIONS) 13. REMOVE RECESSED BALLASTS AND PULLBOXES. REPLACE WITH MIN. 4"P.C.C. 14. REMOVE POLE FOUNDATION COMR.ETE. REPLACE WlTH MIN. 4" P.C.C. 15. ALL SIGNAL HARDWARE SHALL BE NEW, EXCEPT POLES AS NOTED. 1£. ALL REMOVED SIGNAL EQUIPMENT IS TO BE SALVAGED. 17. REMOVE PORTION OF EXISTING MEDIAN ISLAND AND (X)NSTRUCT NEW NOSE IN KIND. FILL AND PATCH EXPOSED AREA AS NEEDED TO MATCH SURROUNDING ROADWAY SURFACE. 18. SEE SPECIAL PROVISIONS FOR SPECIAL DETECTOR OPERATIONS. / EXISTING 1" INTERCONNECT CONDUIT AND 4#14 INTERCONNECT CONDUCTORS \;- '\' _ _Jf'1~,~~'/i~-pgo~R~T\~~i~-~ .. ,--~~;:-~-~-·;GA~s~-J;-~~---§· ~-~-§~ ~~~f--~ _.,., ----~-== , .. • ~ \<' e:, ·;:_.-._:-_.. ._: ='~ --~--, , ~EE·N~TES 13614 i i i/2" C., 2 LOOP CI\BLES ----__,---, ,,-..,. \ I • \\ a~ __ ---ScW!~-----SEE NOTE 5 _.,,.......-1 1 ....,.,i-< w SE.'NER ,l.__l_ ~\\~=""~;:::;+::-lfl:\-----:===-=-60' '-a> ... "' "' N v ____ --WAT~~ER------ --=-===t=, = .... t=-=+-'f---__J1--=--=- II ·g -lfl -\ll ~ ·v ' TO BC R '~-0 ¢ _ '.?_ 160 • • • '.J'_ _:_ _______ _ -., EDISON-- ~ -• ' • ~-- ~- \ \ SEE NOTES 12 13. IN ALL No. PHASE __Jr _) ...,.. ___ ,.._ AL+ A3 Ai +A2 --4-___ ...., ~ )f f ~- A3 +A4 A2 +A4 PRE F!oRED SEQUENCE WITH CALLS ON ALL PHASES CONTROLLER MODULE PHASE Ai A2 A3 I CONDUCTOR ll\_ 11 DIAGRAM IAWGI CIRCUIT 0A1 0A2 84 B2 0A3 0A4 ' 082 & 084 #-0A2 PED 0A4 PED 14 0B4 PED 0A2 PPB 0A4 PPB 0B4 PPB SPARES SCHEDULE TOTAL A4 82 84 # PPB COMMON TABLE I I RUNS -I :~l~l&l&l&l&l&I~: 2 2 '2 4 3 3 -3 6 2 2 2·, 2 2 4 3 3 3 3 3 6 3 3 3 3 3 6 2 2 2 2 2 2 2 4 2 2 2 2 2 4 1 1 1 1 1 1 1 1 1 1· 1 i 3 3 3 3 3 3 6 17 22 22 24 17 • 47 i i 1 1 1 1 MODULE TYPE s DP s .DP s SP 12 I.S.N.S. 1~* 1 i i 1 2· TOTAL 2 ,3 2 2 2 2 ~SERVICE CONDUIT I 3 #8 LOCATION APPROX !MATE DETERMINE IN FIELD. NEMA DESIGNATION 1 6 5 .2 8 7 INSTALL MODIFIED TYPE JI 120/240V. SIGNAL AND ____ _, LIGHTING SERVICE IN ACCORDANCE WITH CITY STD. DRAWING No. 910-L. ADD A METERED BREAKER FOR I.S.N.S. OA1 Q DET. 0A!&A2 DET. LOOP 0A3 & Q DET. 1 0A4 DET. E 082 & B4 DET. TOTAL CABLES 0A2 DET. 2 MAG 0A4 DET. TOTAL CABLES 2 # LUMINAIRE 2 SIGNAL 6 SIGN COM -1 10 TOTAL 3 1#14 INTER. & PRE·EMP• I -I - I CONDUIT SIZE I (E) I !E 1.' I 1 ,1 1 I i i· 1 2 1 i 1 ,i .1 ·1 1 ,2 1 3 14 3 7 2 2 2 2 2 2 2 2 4 4 4 2 2 2 2 4' 1 l 1 1 2 3 3 3 3 6 11 11 11 4 I ,II I 311 3' 3" 3" I 2-3"1 ( 1 1/2" CONDUIT i·LOOP CABLE ** FOR FUTURE USE. (E)=EXISTING CONDUIT ID BE RE-USED. ' 2 -MAG. CABLE ,,..--#31/2 PB -~-: ~-·-=--:-::.,-G· t=~'=?.•""".··=-=··==· =--~---~r~~-~=~-====~--s~ . BOULEVARD (1 '" '.' ', ,,' ' _-, ~-flBM::::::ORAffll--==-:-==:==r---,-, ,, " ' ' ' ·" " " ----=[] -'---~ ' , . ,. " •<• ' \ U/-tv • • • • -.... ,. • ·' . '' -.~---' ' SEWER ABANDON 1____./. 16D'TO BCR 'NATER BO' I I R=RADIUS o B 7" 7A -A-, C o-+----•J_ Lol® _-,·,,6J_=, __ ,+-•• NL-:----,-,c:_~ ... T+":__~~--~~.,,..B.,,-~=;=~ij', ='~[~·=·='·=$· :i_~. f_=,_._:::. __ .= ... =., .. =. ,=m~~-=-~m~? #~I~. ~ B ..,,__,...'-_L_" _·:D N~U:T 6) --i.. , -: =.--=·"' ·"" 1· ,,·· t c./·1_·: ;_r -IAT'ir,-,-+1-~--:+l":-+:_-_J-1/i..ffe® 7 ~ \ ·"1: - ' 2-MAG. CABLE 160, J, 2-E-ef2 .•, ·'· ' .. , ; ,. . . \,,!_REMOVE CABINE~ AN~ FOUNDATIONS ' • ,, ; • ' COMPLETE. REPLACE WITH MIN. 4" P.C.C. □ ' □ □ POLE LOCATION DETAIL ( EXACT LOCATION BY ENGINEER IN FIELD) SIGNAL LUMINAIRE POLE -.SCHEDULE SIGNAL MOUNTING PED. PUSH "BLITTON POLE LOCATION POLE TYPE LENGlH M.A. M.A. WATTAGE VEH. M.A. PED TYPE PHASE POLEQUAD A 8 C R 1 R 66D6 301-911 2 N 24 4· 30' 35' 12' 250 SV-2-T MAS SP-2-T B MAS B 3 E 66D6 30..'. 911 6'· 250 SV-1-T B 4 N 1,-A lO' V-1-T SP-1-T 5R I 7' 6 R 66D6 301-911 7N 24·4·70 30' 35' 12' 250 SV-1-T MAS SP-1-:r 8 E I 10' (, TV-1-T 9 E 66D6 30~911 6' 250 2-T ID R 1-A 7' ,. LS.N.S.= ILLUMINATED STREET NAME SIGN. * = USE EXISTING MOUNTING LOCATION. R= REMOVE -SEE NOTE 14. E = EXISTING TO BE REUSED N = NEW POLE. 11-75 DIETERICH•POST 2111B .003 MAS B SP-2-TJE B A4 EAST -5' 25' ' 84 SOUTH 5' A4 * 5' 25' 30' -4' 3' 2d /1.2 WEST 84 LS. N .S. DOUBLE FACE 32 nd. St. 32 nd. St. • --, 7 I LOOP CABLqtt-~~--=---'::'--:__--"---- NOTE 12 6 13/ / ::, _ ;// , .\· 1. REPLACE EXISTING P.B. WITH NEW No. 6. PROTECT EXISTING INTERCONNECT -(l AND PRE-EMPT CONDUITS Bi CONDUCTORS IN A.ACE FOR REUSE ( SEE INSTALL NEW PPB, I' , ,• \ SPECIAL PROVISIONS). POST MTD.,FOR 0A2 -~I •.• _· USE r'-CON DUIT. I I-,:' 'REMOVE P.P.a AND POST -~) SEE NOTE l4. ' I I --' I 1 E-82 I 0- SENSOR TABLE SENSOR CHANNEL DETECTOR 1 1 1-S -Al 2 1-S-A2 3 1-N-A3 4 1-N-A4 1. 2-S-At BIKE PUSH BTN. PHASE FOLE QD I I I I 7EXIST. !" C., 5#l4 SIGNAL PRE· EMPT CONDUCTORS TO FIRE STATION(RE- USE). 3M SECTIONS TYPE 131 0 s" 0 0 0 2 2-N-A3 3 i-E-B2 . 4 2-E-B2 • 8-4 A-4 A-2 NORTH EAST SOUTH WEST t--= en 4' I I ffi ,. r r(f)i '-- ' .. ... ·, C ' • ',, ' . 3M DUAL COLOR SECTION TYPE 133--- POLES@&(D MAST-ARM MOUNTED (PROGRAMMED VISIBILITY) 0A1tA2 & 0A31-A4 r 0 __ ct ct POLES@&@ (NON-PROGRAMMED VISIBILITY) OA1+A2 & OA3+A4 3·7· 79 HLG REVISED NOTE 6 • ALL r 084 LOCATIONS (NON-PROGRAMMED VISIBILITY) APPROVED 4 1 l-W-84 2 2-W-B4 SENSOR MAGNETOMETERS 1 A/8 2·S·A2/3·S·A2 1--~--+-~~~-2 A/B 2·N·A4/3·N·A4 * SENSOR SHALL HAVE INTEGRAL . DELAY C/l.PABILITY FOR EACH CHANNEL (SEE SPEOAL PROVISIONS) r r TRAFFIC SIGNAL PLAN ·W°"J'(! ~L ------~----i l------+--1--------------+----I TRAFFicENGINEER NEWPORT BOULEVARD ------...... PR_E_PA-RE_D_BY-, -----DAT R.~E:r~;:~~;5 AND 32nd. STREET ,0 '] I ~ /J /J • DESIGNED DRAWN • F-· ..xr5t-,,, ~ M,,~l7,tj'? DATE BY DESCRIPTION APP'D. SOMMERS SOMMERS c1Tv oF NEWPORT BEACH DESIGN ENGR. l'l.C.E.10692 DATE REVISIONS CHECKED DATE , • PUBLIC WORKS DEPARTMENT R.HM. 5 -77 MDHLE,PERRY &ASSOC. T-5200-S SHEET I OF I " -· ""-( \ ' ) , ' " ~ I \J