HomeMy WebLinkAboutT_5449_SI I POLE SCHEDULE STANDARD LUMINAIRE I.S.N,S. SIGNAL MTG. NO. TYPE HEIGHT SIG.M.A. LUM.M.A. VEHICLE PED. 0 TYPE 15 30' 15' 250 HPSV ® TYPE 15 30' 15' 250 HPSV SP· I-CS (3) 17·2-70 30' 18' 15' 250 HPSV Bristol St. MAS SVi!-TD (4) 26-4·70 30' 45' 15' 250 HPSV Bayview Pl. 2 MAS SV-1-T SP-I-CS BRISTOL 16" G ~ <\J --._, "' ~ ri"> 3001 TO - i STOP BAR 4 11 G 11/2 C. ANO 4 O.L .C. PPB/ BIKE POLE PHASE A 2/-11' -/2 14' SEE PLAN 2/-16.5' POLE LOCATION B 2.5' 2.5' 3' 2:5' 4P-1-....L.. , A ' -Is ~ LOCATIONS GENERAL NOTES: I. ALL WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE REQUIREMENTS OF THE STATE OF CALIF, DEPT. OF TRANSPORTATION, STANDARD PLANS AND STANDARD SPECIFICATIONS DATED JULY 1984 AND THE SPECIAL PROVIS IONS FOR THIS PROJECT. 2. UTILITIES SHQ\1/'t,J ON THESE PLANS ARE CORRECT AND ACCURATE TO THE EXTENT OF AVAILABLE RECORDS AND KNOWLEDGE. THE CONTRACTOR, HOWEVER, IS REQUIRED TO ASCERTAIN THE EXACT LOCATION OF UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE. 3. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND NOTIFY ALL UTILITY COMPANIES A MINIMUM OF 48 HOURS PRIOR TO START OF CONSTRUCTION IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORD !NATE ALL PHASES OF CONSTRUCTION WITH THE VARIOUS UTILITY COMPANIES INVOLVED. 4. ALL PULLBOXES SHALL BE No. 5 UNLESS OTHERWISE NOTED. 5. ALL SIGNAL HEADS SHALL HAVE 12" INDICATIONS AND BACK PLATES 6. PEDESTRIAN INDICATIONS SHALL BE TYPE "C' WITH INTERNATIONAL SYMBOL DISPLAY. 7. LUMJNAIRES SHALL HAVE INTEGRAL BALLASTS AND TYPE IV PHOTOELECTRIC CONTROL. 8. NEW PAVEMENT MARKINGS SHALL BE ESTABLISHED PRIOR TO LOOP INSTALLATION 9. LOOPS SHALL BE 6' x 6' CENTER ED IN DIRECTION OF TRAVEL, UNLESS NOTED OTHERWISE. ID. CONDUCTORS AND POLE SCHEDULES ARE FURNISHED AS INSTALLATION. GUIDES ONLY. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROVIDE THE CORRECT EQUIPMENT REQUIRED FOR THE INTEDEO OPERATION. I I. INSTALL TYA:: A INTERNALLY ILLUMINATED STREET NAME SIGNS. SEE POLE SCHEDULE AND DETAIL C SHEET 33 OF 33 . -INDCATES. ILLUMINATED STREET NAME SIGN. 12 MEDIAN·NOSES TD BE MARKED PER DETAIL H SHEET 33 OF33, 13 THE ENGINEER SHALL APRDVE FOLE, LOOP DETECTOR AND CONTROLLER PLACEMENT IN THE FIELD. PR JO~ TO INSTALLATION. 14. PRIOR TO START OF ANY CONSTRUSTION WORK, CONTRACTOR SHALL OBTAIN EMA/PUBLIC PROPERTY PERMIT. 15. P.PB.'S AND PED HEADS SHALL HAVE INTERNATIONAL SYMBOL DISPLAYS. ~..d---~0. ___ _ 42" CM CW D 4 11 G ~ STREET EXIST] l'IG CURB :,._ _____ _ @s §v @ G DETAIL "A" ( POLE@) 16" G \ __...---'f-------_;' _____ -:-:-==-=====--=-=-:-----------_-_-_-_-_-_-_cc]a~G::7 -___ A --~---------~~--~--------------------1 1/2" c. AND 12 ·PR 1119 INTERCONNECT CABLE :::.::.:=========-=--=-= V ~-----~~-------------\-------j--------c--~~~ ,--------------------R/w/ CONDUCTOR SCHEDULE PHASE DIAGRAM 02 04 02 3 3 3 3 04 3 3 3 3 +----➔ 02P 2 2 2 4 .. 02PPB 14 02 BIKE PPB COM I I 2 !SNS I I I I SPARES 3 3 3 3 6 ONLY ONLY J•10 ISIG COM I I I I I I I I I 2 I I I I : LUMINAIRE: 2 2 2 2 IQTAL 3 3 3 3 2 DETAIL II B11 I-1212-c I I I·02· P I I R 61 MODIFIED SIGN 2-02- P I I I-04-P I I 2•Ql2·C I I DLC. 3•(112-C I I PHASE SEQUENCE 4-02·C I I o::J---0:J TOTAL I. :s .7 Ii~ PR .l"I9 CABLE I I I I I I 12 I I I I I CONDUIT SIZE i 2" f 2" f2l/2'f 2" 12-3' 1 I i i I 112."C.AN 4*10 LTG. 2 I 1-04-P 2-04-P I I"' o,-' -"' .... 0: 0 a. I- lllGl i! 14' 12' 2 2' .,. (.) w : 0- ~z --'ii 35' 8 BAYVIEW PLACE ' CALIFORNIA DEPARTMENT OF TRANSPORTATION CONCURRENCE: JOHN E. REEVES, CHIEF /~/r/,#,£/4 DATE I I C CONSTRUCTION NOTES: OJ FURNISH AND INSTALL A STATE TYPE 170 CONTROLLER ASSEMBLY WITH STATE TYPE MODEL 400 MODEM, SfATE TYPE 332 CABINET, FOUNDATION PER STATE STANDARD PLAN ES-4B AND AUXILIARY EQUIPMENT TO PROVIDE OPERATION AS SHOWN ON PLAN AND IN THE SPECIAL PROVISION. @) FURNISH AND INS TALL A TYPE m·B MODIFIED 120 I 2 40 VOLT SIGNAL SERVICE. SEE DETAIL. ES·2D OF CAL1'RANS' STANDARD PLANS. CONTACT MIKE MARTIN WITH EDISON AT @] III (714) 895-0261 72 HOURS PRIOR. INSTALL 11/2" CONDUIT AND 12 PAIRlf19 TWISTED SHIELDED INTERCONNECT CABLE TO CONTROLLER AT BRISTOL AND JAMBOREE APPROX. 870'. INSTALL R6I MODIFIED SIGN ON MAST ARM OF POLE®· SEE DETAIL" B• THIS SHEET. INSTALL R96 AND R96A SIGNS ( NO PED XING). 'l<'I< "APPROVED FOR CONCEPT AND ADHERENCE TO CITY OF NEWPORT BEACH CITY STANDARDS AND REQUIREMENTS ONLY. CITY IS NOT RESPONSIBLE FOR DESIGN APPROVEb BY ASSUMPTIONS AND ACCURACY." Q /,' , '.l°/2 I _/4,: ~:ia_,d .II!. ;7/4,,,.,.,,J,h TRAFFIC ENGINEER RCE 22045 'DATE ORANGE COUNTY EMA PLANS PREPARED BY .,de. ·-;--[. It.or= l'L/,;,,.-~'.~F-Q,,~ 5.l-, L ' /Z--(O-'iJS°' S.M. HOGAN TRAFFIC MANAGER DATE ca ~1'aC. ,P MARK DATE AS BUILT COMPLETED 3;3100 BY g)Q£ .. ~ 3 inches on original drawing ORANGE COUNTY ENVIRONMENTAL MANAGEMENT AGENCY TRAFFIC SIGNAL INSTALLATION BRISTOL STREET AT BAYVIEW PLACE ---DESCRIPTION PREPARED UNDER SHEET TRAFFIC OPERATION BRANCH I/ C.R NELSON DIRECTOR OF PUBLIC WORKS DATE ;:r7c'.4J. ~ GirNGIN7iR !Ll!E. No. 22338 DATE " 8 BASMACIYAN -DARNELL, INC. SUPERVISION 0~ .REVlilONS DATE 25 \_ SUBM!TTE.O B,Y REVIEWED BY REVIEWED BY DATE 1?;10 /,is 3190 C-1 AIRPORT LOOP DR. t;;., / v' -:Y?J. ~.,,;,-\ <!E" .22-1.38 I COSTA MESA, CA. 92626 o"'""'-..... SCALE DATE DWG. NO. of • • i jf DESIGNED . / ;/~ ;:;z, • od:; K.R. SMITH PROGRAM MANAGER DATE f I p:;½/ r .....,.,> ', L., __ L-C/;'7 ,::,,-,~t,; ( 714) 557-5780 lcHECKED~ l 111 =< 201 T-5/./4'i-;-5 35. ,, 7,,.,.-z..t,.,,,y/ a-..,._.,,._,.. '; /,, ·!l DRAWN en :r 1"11 m -l I ' l c_n