HomeMy WebLinkAboutT_5712_S:
CONDUCTOR SCHEDULE SANT A BARBARA DRIVE PHASE-FU~~CTION-SEQUENCE DIAGRAtv1
AWG CIRCUIT
¢1 3 3 - -3 3
¢2 3 3 - - 3 3
¢3 3 3 3 3 6 6
¢4 3 3 - -3 3
¢5 - -3 3 3 3
¢6 3 3 - - 3 3
¢2 P - 2 - - 2 2
¢4P 22--22
¢6 P 2 2 2 2 4 4
02 PPB & BPB - 1 - - 1 1
#14t-¢3,---=-:BP=B----t---+----+-----l---+--1:..+-~1+-----l
¢4 PPB 1 1 - - 1 1
06 PPB & BPB 1 1 1 1 2 2
PPB & BPB COMMON 1 1 1 1 2 2
SPARES 3 3 3 3 6 6
TOTAL 25 28 13 13 42 42
4112 ISNS 1 1 1 1 2 2
SIGNAL COMMON 1 1 1 1 2 2
#1Qt-----'-LU_M~IN_A_IR=E~S ___ -+-2::...+=2c..+-=2---l--=2=---+--=2---l--=2=---+-----1
ro~L 3 3 3 3 4 4
¢1 - - - 2 2 2
I/J2 - 5 - - 5 5
LOOP 03 - - - - 5 5 D ET. t-¢-4------+-2-+--2'--+--_-1--_-+---'-2'--+--=--2 --1---1
CABLE 05 -1 --1 1
TYPE1---I/J6-----+---+---'----l-1-----+-2--l----2-'------l--~s~ ' ········-······ ......
ALL
SECTIONS
12"
0
0
0
@
DETAIL
B 1----------'-'l---+----+---l---+__;l----+---I ••••• ••• .. •••••••••••
~: 1 A 240•
...!. L l __ TO VBCR '
1--~-1-E~-~-i-:-L~-E-CT-C-AB_L_E-1--1-+--:,,...1 +-=-1 --1--~-+-1[-+-2-;--+---I .. ! [::::1 __ ]:::::::
CONDUIT SIZE 2'\.., 3" 2" 2" 2-3" 2-3" 9-i : ··1
ALL CONDUIT EXISTING
ALL CONDUCTORS TO BE INSTALLED NEW
REUSE EXIST. I.C. AND EVP CABLE
J"") .i. ······l ! \. ·\ ......... .. .... ..
' '
RED
.
YELLOW
GREEN
GREEN
,, A,,
¢3 AND ¢4
*INTERIM DETECTION IS ONE LOOP
IN EACH LANE.
(SEE INTERIM STRIPING DETAIL
ON SHEET 4)
PROVIDE CONDUCTORS AND OTHER
EQUIPMENT REQUIRED FOR THE
INTENDED OPERATION.
·<:::.:::::········=····=····=·· =,::;::= === 'C<,·········
N
N
... , ........ , .. .
.... _ .. ,._, ____ ..... -................ ··!5~S ······ .. ---• ........... ,. ... ................................ ---.....
\__re, 3DLC
JAMBOREE
19'
1-¢
11'
C
-
J__
I
12'
LJJ_.---ONSITE ROADWAY IMPROVEMENTS
BY OTHERS
12·
MAST ARM, AND
......
VEHICULAR & PEDESTRIAN
MOVEMENTS PER FUNCTION
N.E.M.A. PHASE DESIGNATION
FUNCTION TYPE
COORDINATE FUNCTION *
IT]
'
LUMINAIRE RO AD
1 5 2 6
s s DP DP
* * * *
,-----;;,.f: 2+5:1----~
3
s
*
NOT
USED
7
s
*
NOT
USED
8
DP
*
4
DP
I \li
1 1+s1-:-----~,?2+:i:'i5n;1----~ 3 1-j -----~>l 4 1
1'-----;;,.l: 1+6 :1----__,/tl
250'
LIMIT
v1~C: 30LC
l ; ;
l 1 1/2"C, 18PRf22 1.C.
TO SAN JOAQUIN HILLS
RD. (±930')
SENSOR UNIT CHANNEL DETECTOR
#1 1 (1) 1-02 1
2 (2) 2-02 2
#6 21 (6) 3-ill6 9
4-ill6
#7 1 (R) 5-¢6
2 (R) 1-04 10
#8 1 (R) 2-04 11
2 (R) (7) 1-I/J3 12
#9 1 (R) (8) 2-03 13
2 (R) 3-03
(N) NEW SENSOR UNIT
(R) REASSIGNED EXISTING SENSOR CHANNEL
6 SENSOR UNITS WILL
BE RACK MOUNT WITH MULTIPLE
OUTPUTS. SEE NOTE OJ AND
SPECIAL PROVISIONS.
II] VCS INPUT NUMBER
! o ...__....JRS (EXIST HEAD)
. ,::.. ~ !~~.1HEJ~ : I :l'J'··'l. s·1°l
1
~ .. ·i/ 111;rc. 20Lc
1 1 /2"C, 3DLC, 18PR#22 J.C. (#) SYSTEM SAMPLING NUMBER
FURNISH AND INSTALL ONE (1)
GENERAL NOTES
1. TRAFFIC SIGNAL AND HIGHWAY LIGHTING CONSTRUCTION SHALL CONFORM TO THIS PLAN, STATE OF CALIFORNIA
STANDARD SPECIFICATIONS AND STANDARD PLANS (DATED JULY 1992) AND THE SPECIAL PROVISIONS.
2. CONDUCTOR SCHEDULE IS FURNISHED AS AN INSTALLATION GUIDELINE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
PROVIDE THE CORRECT CONDUCTORS REQUIRED FOR THE INTENDED OPERATION.
3. ALL CONDUIT INSTALLED BETWEEN ADJOINING PULLBOXES SHALL BE 2 1/2" UNLESS SHOWN OTHERWISE, AND SHALL HAVE 30" MIN. COVER.
4. NEW PULLBOXES SHALL BE #5 UNLESS SHOWN OTHERWISE.
5. CONTRACTOR SHALL EXERCISE EXTREME CARE TO AVOID DAMAGING EXISTING UTILITIES.
6. UNGROUNDED SIGNAL CONDUCTORS SHALL NOT BE SPLICED.
7. ALL SALVAGED MATERIALS & EQUIPMENT SHALL BECOME THE PROPERTY OF THE CONTRACTOR EXCEPT AS NOTED.
8. EXCEPT AS OTHERWISE NOTED, LOOP DETECTORS SHALL BE 6'X6' CENTERED IN TRAVEL LANE, WITH 10' SPACING.
9. ALL SIGNAL CABINET MODIFICATIONS SHALL BE MADE BY THE MANUFACTURER.
NOTES THIS SHEET
[iJ EXISTING MUL Tl SONICS MODEL 820 CONTROLLER, OPTICOM EQUIPMENT, AND BICYCLE TIMING LOGIC IN TYPE P CABINET
WITH DETECTION AS SHOWN, VEHICLE COUNTING SYSTEM, 24 VOLT FIRE STATION PRE-EMPT EQUIPMENT, AND MISCELLANEOUS
AUXILIARY EQUIPMENT TO BE MODIFIED AS REQUIRED TO PROVIDE THE INTENDED OPERATION.
II] EXISTING MODIFIED TYPE II SERVICE WITH 50 AMP BREAKER FOR SIGNAL, 30 AMP BREAKER FOR LUMINAIRE
(UNMETERED), 15 AMP BREAKER FOR ISNS AND 15 AMP BREAKER SPARE TO REMAIN.
QJ REMOVE EXISTING SIGN PANELS INDICATED FROM EXISTING SIGNAL STANDARD AND INSTALL ON NEW
SIGNAL STANDARD PER CALTRANS STANDARD PLAN NO. RS4.
0 REMOVE AND SALVAGE EXISTING SIGN. INSTALL NEW R73-5 SIGN ON SIGNAL MAST ARM
PER CALTRANS SID. PLAN NO. ES-6T.
EVP DISCRIMINATOR UNIT (¢3 AND ¢4)
, , ;' i , ! ; . : ;; ; .. .. ; i ';'I' 6PR#19 J.C .
.• : .... .,.. j ; i ' : ; i iii i ! !
' j '
! ' ' .
'
' f
SANTA
i
!
.. . .... ·,;,.-.. ; ; : ... ..., ..... 1 ....... , ..... j .. ·'""'"""'"'· .. ·; ......... ; .............. .,. ...... ; •.
,. . " • ' i ;
14' 12' 112· ,12' i :: i 1~·., ,_! l!t· I;!;
i j; ' ' ' ' ' ' ;
' f
' ! '
' !
' ' ' f i
j.f
' f j .
j ;
i
; ;
if
.
ff
f
.11 • ;r;3 : ·~-, 1 •
1'....1..---'--L.I....C-' ..... i ---1--
ii I'
. '
I
i
j
' ' I I
! ! j
i '
20 10 0 20 40
3 INCHES ON ORIGINAL DRAWING
POLE SCHEDULE
POLE DATA SIGNAL H.P. SOD YAP SIGNAL MOUNTING PED. PUSH BUTTON POLE LOCATION ILLUMINATED SIGN
NO. TYPE HEIGHT M.A. M.A. WAT ::, YEH. M.A. PED. PHASE POLE QUAD. E B C N MESSAGE (DBL FACE)
1 24-4-70 30' 35' 15' 250 SV-1-T MAS SP-I-CS 2 NW 15.5' 2.5' Jamboree
j
' .
y;2~~1~A(S'E);;;;:.l-:1:::0;-' +--::--:c-=-+-::-;--;-::-;--l--c-:--:--hTV:_;,-,..:1~(E~) -t-m--+SP'---1--T-"(E'-'-) 1---'4 f..::2_• -+-~NE°"'(E::!c)/'-'N'-"W(-"'E'-'-) --1---..::Ex::::is:.::ti:.:.;na!__--1---------1 t-•➔3~-::29:::::-::--,5-::-::70::::(E~)f---'3:c:O_' -t-__:5:.:.0'~(E:!..)+1.::_5'(~EI-) i--.:2::.::5:.:.0-4_,.i!!~iv:::.t-11:..!.~~--l-'i2=~ SP-1-CS Exist in a Sonia Barbaro (E)
!
' '
1 ;
i !
r
4 PPB POST
6
7
8
9
1A 10' TV-2 SP-1-CS
19-4-70 30' 25' 15' 250 SV-1-T MAS
IA 10· TV-1 SP-1-CS
29-5-70 30' 55' 15' 250 SV-1-T 3-MAS SP-I-CS
1A(E) 10· TV-2(1' --
e SPECIAL PUSH BUTTON WITH BICYCLE SYMBOL, MESSAGE & ARROW
NOTE: ALL EQUIPMENT NEW, EXCEPT THAT NOTED AS EXISTING (E), OR
-'---.I
4 NE 12' 2.5' -
SE/NE -12· 2.5'
6 SE 12' 2.5' -Jamboree
6• SE -12' 2.5'
6.5' 2.5' Santo Barbaro (E
2/3 • SE El/SW Existino
(1) -INSTALL NEW VEHICLE HEADS WITH NEW TV-2 MOUNTING HARDWARE ON EXIST. POLE.
CITY OF NEWPORT BEACH
THIS PLAN IS SIGNED BY THE CITY OF NEWPORT BEACH FOR CONCEPT
AND ADHERENCE TO CITY STANDARDS AND REQUIREMENTS ONLY. t----J--+----------+---1
THE CITY IS NOT RESPONSIBLE FOR DESIGN ASSUMPTIONS AND'---!--+----------+--!
ACCURACY. 1
APPROVEP ~x· gi,_,,...fi,_
DATE BY DESCRll'TION DESIGNED
APP'D. KRR
TR1\FFIC EN !NEER
l-/0•9h
DATE REVISIONS CHECKED
DRAWN
LHK
DATE
TRAffiC SIGNAL MOD1F1CA 1lON PLAN:
JAMBOREE ROAD
AT SANTA BARBARA DRIVE
CITY OF NEWPORT BEACH 1K· :,011
PUBLIC WORKS DEPARTMENT SHEET 5 o, 8
I \_
TI\le K: \PROJECTS\177 _0200\SIGNAL \SHT5.0WG 12/21/95 10: 54;
--
2 ,.
D ~
l.i1
z
C
?; m m :0
z
~~---'
0
:0 ~ z
G1
z
C s: m m :0
~o JJ
lit·-~ ·~ z
" G) l'l ~ I ?: . rn
U) ~
D
I)
~ z