Loading...
HomeMy WebLinkAboutT_5778_SCl :s: <t ◊ ' / ////. AST-A /'~½ 1/,-. ~MODEL 722 OPTICAL DETECTOR SET SCREWS DRILL & TAP 5/8" HOLE IN MAST ARM SJRAP /CLAMP EVP DETECTOR MOUNTING DIET AIL I _ __:e---, INSTALL 2"C, 3 DLC-._ RELOCATE ST. LIGHT I CONDUCTOR SCHEDULE RUN NUMBER CIRCUIT 01 3 3 3 3 3 6 3 6 3 3 3 3 3 3 3 3 6 3 3 3 3 3 3 3 3 3 ¢8 3 3 3 6 ¢2P 2 4 ¢1 r;;7 PROPOSED TRAFFIC SIGNAL L::'.J MAINTENANCE EASEMENT PHASE DIAGRAM ¢2 ¢3 ¢4 #14~¢_4_P _____ --+_2--+_2--+_2--+---+-2--+-4___, / I l 06P 2 2 2 2 08P 2 2 4 t ◄-----► . CD ¢2PPB/BPB i!>4PPB ¢6PPB/BPB 1 1 J ◄-----► f I .,../ ¢8PPB PPB COMMON SPARES TOTAL SIGNAL COMMON #1 Q LUMINAIRES TOTAL ¢1 1 3 25 1 2 3 1 3 32 1 2 3 3 32 1 2 3 3 6 1 3 23 1 2 ·3 2 6 66 2 4 6 02 3 6 6 ¢8 (FUTURE 03)· 1" ¢4 1 DLC ill5 1 1---~~------!--+---+----+----+--!---I ¢6 3 6 6 ¢4 (FUTURE "17) TOTAL 2 5 9 4 7 18 OPTICOM CABLE 2 INTERCONNECT CABLE 6PR #19 CONDUIT SIZE 3" 3" 3" 3" 3" 3-3" AFA File: 446.022 NEWCOR.OWG 3:34 PM 11/04/98 ¢5 ¢6 ¢7 Underground Service Alert Call: TOLL FREE 1-800 422-4133 ¢8 TWO \\DRKING DAYS BEFORE YOO DIG \ \ i,~_:?~ ¢6 24' ..... c-1 5 PROPOSED TRAFFIC SIGNAL MAINTENANCE EASEMENT --~~ ¢8 • -<...J...'< Ix ¢, 2 I I I t ¢2 ◄H-l POLE SCHEDULE POLE DATA SIGNAL H.P. SOD. VAP. SIGNAL HEADS AND MOUNTINGS PED. PUSH BUTTON BIKE PUSH BUTTON POLE LOCATION OVERHEAD REFLECTORIZED I--~----~--~ TYPE HEIGHT M.A. M.A. WATTS VEHICULAR M. PEDESTRIAN PHASE ARROW PHASE ARROW 26-4-70 30' 45' 15' 250• SV-1-T 3 MAS SP-1-CS 4P 1-A 1 o· SP-1-CS 6P 17-3-70 30' 25' 12' 250• SV-1-T MAS SP-1-CS 6P 1 o· TV-1-T SP-1-CS BP 6 26-4-70 30' 45' 15' 250• sv-2-Te 3 MAS SP-1-CS BP 1-A 10' TV-2-T SP-1-CS 2P 17-3-70 30' 25' 12' 250• SV-1-T MAS SP-1-CS 2P 1-A 1 o· TV-2-T SP-1-CS 4P 2 e .-¢6 VEHICLE HEAD MOUNTED AT HEIGHT OF 17' II -SEE SPECS --'-I z~=~ NOTE: -ALL SIGNAL POLES AND HEADS SHALL BE PAINTED WHITE -ALL S[GNAL INDICATIONS ARE 12" -ALL RED INDICATIONS TO BE CAL TRANS APPROVED LIGHT EMITTING DIODES. (LED'S), EXCEPT P.V. HEADS -ALL PED PUSH BUTTONS TO MEET A.D.A. SIZE REQUIREMENTS SCALE: 1" = 20' • -LUMINAIRES SHALL BE FULL CUT-OFF ~,--:,,_ _ _::© ... ✓ ' ·, -' 6-¢6 +.-··-rt\ ; 5-¢6 INST ALL 2"t, 3 DLC,--....... 4-¢6 1-¢1 DRIVE ' CENTER "8" ''E" 12' 4' 12· 10· 10· "C'' 2.5' 2.5' 2.5' 2,5' 2.5' 5' 2.5' STREET NAME SIGN II dbl. face Corporate Plaza Newport Center Corporate Plaza Newport Center 2.5' - SCE V ULT #4392 .... CS.ER_ CE POINT) 0 <¢,_;;:~ 4_:~21'\--t-=--==~3==--------------in --. 1 • j 38' I I I I . 0 I ,... '° --------__ . _______ .. ------- _______ .. GENERAL NOTES INST ALL 2"C, 6 PR #19 SIC ALL WORK, MATERIAL, AND EQUIPMENT SHALL CONFORM TO THE REQUIREMENTS OF THE STATE OF CALIFORNIA, DEPT. OF TRANSPORTATION, ST AND ARD PLANS AND ST AND ARD SPECIFICATIONS DATED JULY, 1992, THE CITY OF NEWPORT BEACH DESIGN CRITERIA . STANDARD SPECIAL PROVISIONS, AND STANDARD DRAWINGS, 1994 ED., AND THE SPECIAL PROVISIONS FOR THIS PROJECT. 2. SEE STREET IMPROVEMENT PLAN FOR UTILITIES. THE CONTRACTOR IS REQUIRED TO ASCERTAIN THE EXACT LOCATION OF UNDERGROUND FACILITIES PRIOR TO DOING WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE. 3. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND NOTIFY ALL UTILITY COMPANIES A MINIMUM OF 48 HOURS PRIOR TO START OF CONSTRUCTION. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE 'ALL PHASES OF CONSTRUCTION WITH THE VARIOUS UTILITY COMPANIES INVOLVED. 4. THE ENGINEER SHALL APPROVE THE EXACT LOCATION OF ALL PULL BOXES, CONDUITS, DETECTOR LOOPS, CONTROLLER AND POLES IN THE FIELD. 5. ALL PULL BOXES SHALL BE NO. 5 UNLESS OTHERWISE NOTED ON PLAN. 6. ALL LOOPS SHALL BE 6'X6' SPACED 10' APART, EXTEND LOOPS f INTO X-WALK OR LIMIT LINE UNLESS NOTED OTHERWISE. INSTALL 2"C, 6 PR #19 SIC CONSTRUCTION NOTES 1. 2. 3. 4. 5. 6. FURNISH AND INST ALL ALL NEW SIGNAL EQUIPMENT AS SHOWN. FURNISH AND INSTALL NEW MULTI SONICS 820A CONTROLLER AND ALL NECESSARY EQUIPMENT FOR THE INTENDED OPERATION IN A NEW TYPE P CABINET WIRED FOR 8 PHASE AS SHOWN. FURNISH AND INSTALL MODIFIED TYPE II SERVICE PER CITY OF NEWPORT BEACH STD-910-L AS SHOWN. FURNISH AND INSTALL 3"C, PULLROPE TO EXISTING EDISON VAULT #4392 (SERVICE POINT)AS SHOWN. THE CONTRACTOR SHALL BE ON EDISON'S CONTRACTOR LIST OR APPROVED BY EDISON ,BEFORE ENTERING VAULT. EXISTING IRRIGATION AND UTILITIES SHALL BE PROTECTED OR REPLACED WITHIN 24 HOURS OF DISRUPTION. PROPOSED TRAFFIC SIGNAL MAINTENANCE EASEMENT. FURNISH AND INST ALL OPTICOM EMERGENCY VEHICLE 3M MODEL 722 DETECTOR AND 3M MODEL 138 CABLE FROM DETECTOR TO THE CONTROLLER. DETECTOR MOUNTING PER DETAIL ON THIS SHEET. [Ij FURNISH AND INSTALL 2"C, 6 PAIR #19 INTERCONNECT CABLE TO 7, ALL SALVAGED MATERIAL AND EQUIPMENT SHALL BECOME PROPERTY OF CONTROLLER CABINET AT NEWPORT CENTER AND FARALLON/GRANVILLE. SENSOR 1 2 3 4 5 6 7 8 9 ---fARALLoN OR SENSOR TABLE CHANNEL DETECTOR 1 1-¢1 2 1-¢2 2 2 1 2-ill6 2 3-iZ>6 2 5-112 6-¢2 2 4-¢6 5-¢6 2 • 6-¢6 1 1-¢4 2 2-¢4 1 1-¢8 2 # OF LOOPS (4) (4) (1) ( 1) (1) ( 1) (1) ( 1) (2) (2) (2) (2) (2) (2) (4) (2) (4) (2) CONTRACTOR EXCEPT STREET LIGHTS. SALVAGED STREET LIGHTS (APPROX. 400') SHALL BE DELIVERED TO CITY UTILITIES YARD. CALL (714) 644-3011 II DETECTOR LOOP LOCATIONS SHALL BE APPROVED 24 HRS IN ADVANCE. '87 REMOVE AND RELOCATE CONFLICTING STRIPING. BY ENGINEER IN THE FIELD PRIOR TO INSTALLATION. L:'.J ALL DETECTOR UNITS SHALL BE RACK MOUNTED, DUAL 8. --~~~cIF<~f[~~~~~:lED?~i~~¼G·T~Ai~~~f\16NM~RKEF<Stf\l[)ST_R_I_PI_N_G _____ 191 JsEMOYE STOP_ SIGN. __________________________ g~t~-~E~LD-~i~-~~z:)~IN~E~Ait~~~CA\~r;:131I_NSTE~i~A_L _ __, M " pc CAPABILITY EACH WITH COLORGATED EXTENSION. ~---• ·1 9. THE CONTRACTOR SHALL NOTffY THE ENGINEER AT LEAST 48 HOURS' IN ~ CONSTRUCT •4 •• C. SLAB FROM BACK OF CURB TO CABINET FOUND,ATION. DETECTORS SHALL'NOT EXTEND ON RED.' DETECTORS ADVANCE OF ELECTRICAL WORK AND PRIOR TO REQUIRED INSPECTIONS. '1i"7 RELOCATE EXISTING TREES PRIOR TO SIGNAL TURN-ON. SHALL DELAY ON RED IF SELECTED .. ALL DETECTORS I ~ SHALL HAVE A SECONDARY PRESENCE OUTPUT WITHOUT 10. ALL SIGNAL .HEADS SHALL BE MET AL TYPE. TIMING FOR SYSTEM SAMPLING PURPOSES. "-GJ z C s OJ rn JJ 0 JJ ~ z G1 z C ::;: OJ m JJ 0 JJ ~ z Gl z C s OJ m JJ ~- 0 ~. (#) -SYSTEM SAMPLER NUMBER nr----- 11. PEDESTRIAN INDICATIONS SHALL BE LED TYPE, SEE SPECS. ~~Ill APPROVED TRAFFIC SIGNAL PLAN ~.... AUSTIN-FOUST ASSOC/A TES, INC,, l---l----1----------l.--1...D~T~RA~FFl.;.:IC ~~EN~GIN~~~R L~--N-E_W_P_O_R_T __ C_E_N_T_E_R __ D_R_---1 T RA FF I C £ N CINE£ RI N C A N IJ TR A NS P OR TA TI ON Pl A N NIN C 220<1 c;. UST! AVENUE SANTA ANA, CALIFORNIA 92705-7827 1-1-1/_9_8+--R-s-1-,0=,~A-D-DE_D_VE_H_.I_CL_E_H-EA_D_S_T_o_P_OLE_s_1_&_5-1--V»J<.,---1DATE f.love ... 1:, N;, l'1?13 AT CORPORATE PLAZA Q7.l/4 66 7-0496 FAX (714) 667 -7952 i_:--l--'--i-'='---__: _______ _.::....::..~:.:__i;;:;:;;;;:;;;:;==::::::::'~;';:!;:;:;=:~=cl--------------~----'-~--l . o· DATE DESIGNED DRAWN C 0 C T 5778 S _ _.:::;~~~~~=-=-===--=--=c~-DATE: 1/-:f-TQ BY DESCRIPTION APP'D RS RS ITY F NEWPORT BEA H -• CHECKED DATE 10-98 PUBLIC WORKS DEPARTMENT SHEET 1 OF 1 REVISION,$ i I 0 5 ;,,.c ~ (') o 0 e 1l "' n 0 JJ ~