Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T_6031_S
• • ' j i CONSTRUCTION PLANS FOR TRAFFIC SIGNAL INTERCONNECT CABLE MACARTHUR BLVD. FROM CAMPUS DR. TO FAIRCHILD CC.I.P. NO. 2222) I. 2. 3. 4. 5. 6. 7. a. 9. G■N■RAL NOT■I ALL WORK SHALL CONrORII TO THE STANDARD SPEClrlCATIONS (STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION} , Cl'lY or IRVINE STANDARD DRAWINGS, CITY or IRVINE STANDARD SPECIFICATIONS, Cl'lY or NEWPORT BEACH STANDARD DRAWINGS, Cl'lY OF NEWPORT BEACH STANDARD SPECIFICATIONS, AND THE CURRENT w .. tT.C.H. MANUAL, EACH or THE MOST RECENT DATE. THE CONTRACTOR SHALL NOTlrY TH[ Cl'lY or IRVINE TRArFIC SYSTEMS DEVELOPMENT AT (714)724-7649, THE CITY OF IRVINE INSPECTION SERVICES AT (714)724-6500, PAi PUNl£oAN OF THE CITY or NEWPORT BEACH TRArFIC ENGINEERING AT (714} 644-3311 48 HOURS PRIOR TO ANY EXCAVATIONS. ALL UNDERGROUND rACIUTIES SHALL BE INSTALLED PRIOR TO RESURFACING or STREETS. THE INSTALLATION OF ALL UNDERGROUND rACIUTIES CROSSING EXISTING ARTERIAL HIGHWAYS SHALL BE BORED, UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. ANY EXISTING PAVEMENT DISTURBED BY THE CONSTRUCTION or UNDERGROUND INSTALLATIONS SHALL BE COVERED BY A PERMIT ISSUED BY THE CITY OF IRVINE OR THE CITY or NEWPORT BEACH. IT SHALL BE THE CONTRACTORS RESPONSIBILI'lY TO ARRANGE FOR ANO COORDINATE THE RELOCATION OF ANY EXISTING UTILITIES DEEMED NECESSARY BY THE PROPOSED IMPROVEMENTS. WHENEVER IT BECOMES NECESSARY TO TUNNEL UNDER EXISTING IMPROVEMENTS WITHIN ANY JURISTICTION, THE CONTRACTOR SHALL SUPPORT THOSE IMPROVEMENTS IN A MANNER APPROVED BY THE OWNER'S REPRESENTATIVE OR THE CONTRACTOR SHALL SAWCUT, REMOVE AND REPLACE THOSE IMPROVEMENTS IN I.CCORDANCE WITH THE CITY OF IRVINE OR THE CITY or NEWPORT BEACH STANDI.RD DRAWINGS RESPECTIVELY. I.LL TRENCH EXCAVATIONS SHALL CONFORt.4 TO THE STATE or CALIFORNIA CONSTRUCTION SAFE'lY ORDERS. PRIOR TO PLACING UNDERGROUND UTILITIES, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES (BY POTHOLING OR OTHER t.4EANS) , CONTRACTORS SHALL NOTIFY UNDERGROUND SERVICE ALERT (U.S.I..) BOO/ 422-4133 I.T LEAST 72 HOURS PRIOR TO ANY EXCAVATION TO LOCI.TE EXISTING UTILITIES. ALL CONCRETE WORK AS SHOWN ON PLANS ( CURB &: GUTTER, STORM DRAIN PIPE, MANHOLES, SIDEWALK, ETC.} SHI.LL BE EXTRA STRENGTH CONCRETE WITH 7 SACK TYPE 11 CEMENT OR 6 SACK TYPE V CEMENT, UNLESS DEEMED UNNECESSARY BY SULFATE CONTENT TEST AS I.PPROVED BY THE CITY OF IRVINE, OR THE Cl'lY OF NEWPORT BEACH. FLY ASH ADDITIVES AND / OR SUBSTITUTES SHALL NOT BE PERMITTED. I 0. CONTRACTORS SHALL OBTAIN ANY REQUIRED O.S.H.A. PERMITS PRIOR TO ANY EXCI.VATIONS. 7 6 5 4 3 2 1 ENGINEER'S NOTICE TO CONTRACTOR THE EXISTANCE AND LOCATION or ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS I.RE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITES SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DI.MAGE TO THESE LINES I.ND STRUCTURES. NO. DATE REVISIONS 11. THE CONTRACTOR SHALL REPLACE IN KIND OR BmER ANY LANDSCAPING OR IRRIGATION SYSTEM DAMAGED OR DISTURBED, TO THE SATISFACTION or THE AFrECTED PARCEL OWNER'S REPRESENTATIVE. 12. SLURRY BACKFILL SHI.LL BE REQUIRED WHEN TUNNELING UNDER CURB AND GUTTER, SLURRY BI.CKFILL IS REQUIRED I.ROUND I.LL MANHOLE CONSTRUCTION WITHIN PAVED STREETS. 13. I.RROW SOI.RDS SHI.LL BE USED ON ANY LANE CLOSURES ON ARTERIAL STREETS. 14. ALL rill MATERIAL SHALL BE COMPACTED TO 90% RELATIVE COt.4PACTION I.S DETERt.4INED BY CALIFORNII. TEST t.4ETHODS 2 I 6F. 15. ALL NEW CONDUIT BETWEEN ADJOINING PULL BOXES SHALL BE 2 1 /t SCH. 40 PVC AS PER THE SPECIFICATIONS, UNLESS SHOWN OTHERWISE. 16. SCHEDULE 80 PVC CONDUIT, ELBOWS AND SWEEPS SHALL BE REQUIRED fROt.4 POLE BASE AND CONTROLLER CABINET CONCRETE FOUNDATION TO ADJACENT PULL BOXES. ALL NEW SWEEPS SHALL BE U.L APPROVED SCHEDULE 40 PVC, 45 DEGREE. THESE SWEEPS SHALL BE TERt.4INATED AS FAR APART IN THE PULL BOXES 1.5 POSSIBLE AND ORIENTATED IN THE DIRECTION OF THE CABLE TO fACILITI.TE CABLE PULLING. 17. 18. 19. 20. 21. 22. 23. 24. THERE SHI.LL BE A 3-INCH INTERCONNECT CONDUIT ENTERING THE CONTROLLER CABINET FROM THE ADJACENT #6 PULL BOX. ALL CONDUIT INSTALLED BEHIND CURB fACE SHALL BE 1B-INCHES fROt.4 CURB FACE (Ir PRACTICAL) AT 30-INCH MINIMUt.4 DEPTH IN NATIVE SOIL OR AT 1 B-INCH MINlt.4UM DEPTH UNDER SIDEWALK. ALL NEW CONDUITS CROSSING STREETS SHI.LL BE BORED, 3-INCHES MINlt.4UM AND 30-INCH MINIMUt.4 DEPTH UNLESS SHOWN OTHERWISE. ALL NEW PULL BOXES SHALL BE MINIMUM #5 UNLESS SHOWN OTHERWISE. CONTRACTOR SHALL REPLACE ANY EXISTING DAMAGED PULL BOXES OR CONDUIT. CONTRACTOR SHALL MAINTAIN THE EXISTING SIGNAL INTERCONNECT SYSTEM OPERATIONAL AT ALL TIMES. NO SIGNAL LIGHT CONDUCTORS, EXCEPT CONDUCTORS USED FOR LOOP DETECTOR LEAD-IN CI.BLES, SHALL BE PERt.4ITTED IN INTERCONNECT CONDUIT. A PRE-CONSTRUCTION CONFERENCE WITH lt.4PACTED PARTIES IS REQUIRED PRIOR TO START OF CONSTRUCTION. [:fr. ·•~-~iiffi• offlifif~:"'~~ ., ,CJllJlf N£WPOllt 8[AClf PUlllJC. WOBS,, DEPART.Xt:P1lllll~Ja.~ • :~ • • •. -• . xl~::ftili,'i.mS~"'lfi~ir#"il'JJ NOTICB TO CONTRACTOR PURSUANT TO ASSEMBLY BILL 3019, NO EXCAVATION PERt.41T IS VALID UNLESS THE roLLOWING ARE PERFORt.4ED: 1. UNDERGROUND SERVICE ALERT HI.S BEEN CONTI.CTED AND HAS PROVIDED INQUIRY 1.D,#.'--------- 2. THE CONTRACTOR AGREES TO CONTACT AND OBTAIN AN INQUIRY I.D.# FROt.4 UNDERGROUND SERVICE I.LERT (1-B00-422-4133) AT LEAST TWO (2) WORKING DAYS PRIOR TO THE COt.4t.4ENCEMENT OF EXCAVATION. SIGNED.: ___________ DI.TE:. ____ _ ii ;;;I • !l "-lDN -· I ~ .... ' PROJECT LOCATION CIP-1138 ~ I #> PARK '" ''-"'· i fMNC BlVD. ...... .... fl. TORO w.RIN£ CORPS Nfl. ST,t,n:it, ~ """"""" """""' RD. T I I IMI: """" - IJ 1'i -i i T ~ -= ~ ._-,,,. ~= '#~ ~ ~ • City of lrrine D 1/4 1/% 'S/4 t LOCATION •AP 1 1/2 2. \\ \\ :z .... :::::E Cl:: ~ :z: §.' CAMPUS BIRTCH SHEET ET 5 ~6 ..... ..... "" 0 c,c :::::E .... -, SHEET 7 INDEX •AP PUNS PREPARED BY: RECOWW[NO[O BY: RECOWWENDll) BY: CIP NO. -< o, ,ff,, CITY o, NEWPORT BEACH TRArr1c ENGINEER CITY or 1Rv1NE TRAFnc ENGINEER I N T E R C O N N E C T P LA N ~"H~ PUBLIC WORKS :B/4c(fl1-Ji~-:.__ (!_,.(,,J -~ CIP-2222 $ CONRAD ~NSr, MAC ART H u R B L V D . PROJECT NO. ,~ 1 J)_, TRANSPORTATION SERVICES t-:=-=-~=---T7°~ .. TE~:--r:~~~~~ .. ~~~~.;_--=-i0tiz1~~i1 8495 "C ~ 1-1::,:DRA:::WN:::...::;BY::._: -'=J.l:=LJR=:E====+,:=•=-1=•-=U==-1-~~~BY!,:,.' ..!!TO~W~ [ij""c===:::~~=-1-------------------------------+=:;;;;;;;;;;;;::;;;;;;IV!;;;;;;=~ .. / 1i ,-/: . . 1' ,_ • ,D~ESl~G~•E~D~BYc.:..:• =•·G=•[[=NST[==··=====+=~~=:::~~~•-=·3==~ ENGINi~Rin;~ CH.&.RGE c1.v OF 11v1111J1 ·'lZ.,i'.lii'i_,;J!,:,. 1--•,_.:;<; '·i;/'r/:,';;.. DATE I ~PUBLIC WORKS DEPART"ENT " WRY GREENSTEIN _R,C,[, NO, DATE CHECKED BY: J. LINEHAN t-U-t:S JOHN BROWN R.C.E. DATE M SHEET OF 1 1 • • • OJ • 7 6 • 5 4 3 2 1 NO. DATE CllY BNDRY. -, (,!; ---! -----r-------------"•------ CllY BNDRY . INSTALL HYBRID 25 PAIR #22, 18 FIBER (12 MULTIMODE, 6 SINGLE MODE) INTERCONNECT CABLE IN EXISTING CONDUIT. (REMOVE EXISTING 12 PAIR CABLE WHERE APPLICABLE.) EXISTING #5 PULL BOX. TRIM RISERS AS NECESSARY TO ACCOMMODATE INTERCONNECT CABLE. INSTALL FIBER INTERCONNECT UNIT (FIU) IN EXISTING TRAFFIC SIGNAL CONTROLLER CABINET, AND TERMINATE HYBRID CABLE. INTERCONNECT CONDUIT TO CONTAIN ONLY INTERCONNECT CABLE, PULL ROPE, #8 COPPER BONDING WIRE, AND D.L.C. 's WHERE NECESSARY. UPGRADE EXISTING #3 1/2 PULL BOX TO A #5 PULL BOX MINIMUM. ALL SWEEPS INTO NEW PULL BOXES SHALL BE 45 DEGREE SCHEDULE 40 PVC ELBOWS. THESE ELBOWS SHALL BE TERMINATED AS FAR APART IN THE PULL BOX AS POSSIBLE AND ORIENTED IN THE DIRECTION OF THE CABLE TO FACILITATE CABLE PULLING. . . REVISIONS ..-,,,,;;~- SCALE: 1" = 40' CAMPUS DR. STA. 00+00.00 MACARTHUR BLVD. STA. 66+20.89 1 10 ------- ; •• ----·------------------· ----· ·----------------------_- 4 10 13 3 9 MACARTHUR EXISTING #6 PULL BOX EXISTING INTERCONNECT CABLE TO REMAIN. INSTALL NEW CABINET BASE. (PER DETAIL #3, SHEET 9 OF 9) INSTALL HYBRID INTERCONNECT CABLE FROM CAMPUS DRIVE CONTROLLER CABINET TO BIRCH ST. CONTROLLER CABINET APPROX. 780 FT. BLVD. INSTALL 3" I.C. CONDUIT FROM EXISTING #5 PULL BOX TO NEW CABINET BASE FOR INTERCONNECT CABLE (SEE DETAIL #3, SHEET 9 OF 9). BYPASS #6 PULL BOX. BARRV,-CRITNSTDN R.C.E. NO. DRAWN BY: J. Al.JR[ D£51GNED BY: B, GREENSTEIN CHECKED BY: J LJNEHl,N DA'TE CHECKED BY: DATE 9-16-93 DATE 9-15-93 DATE 0-16-513 DA'TE 1 10 INTERCONNECT PLAN MACARTHUR BLVD. CIP NO. CIP-2222 PROJECT NO. 8495-MC CAMPUS DRIVE TO STA. 59+00.00 1-------------------------------1 SHEET 2 9 CITY OF IRVIME OF PUBLIC WORKS DEPARTMENT 7 6 5 4 3 2 1 NO. DJ 0 8J ~ DATE 9 12 26 4 10 13 14 • 0 LL.JO z· _o -10 :r:J 0l{) f-- <( • ~~ CJ) 10 1 INSTALL HYBRID 25 PAIR #22, 18 FIBER ( 12 MULTI MODE, 6 SINGLE MODE) INTERCONNECT CABLE IN EXISTING CONDUIT. (REMOVE EXISTING 12 PAIR CABLE WHERE APPLICABLE.) EXISTING #5 PULL BOX. TRIM RISERS AS NECESSARY TO ACCOMMODATE INTERCONNECT CABLE. INTERCONNECT CONDUIT TO CONTAIN ONLY INTERCONNECT CABLE, PULL ROPE, #8 COPPER BONDING WIRE, AND D.L.C.'s WHERE NECESSARY. INSTALL NEW CABINET BASE. (PER DETAIL #3, SHEET 9 OF 9) INSTALL HYBRID INTERCONNECT CABLE FROM CAMPUS DRIVE CONTROLLER CABINET TO BIRCH ST. CONTROLLER CABINET APPROX. 780 FT. • REMOVE EXISTING CABINET AND BASE. INSTALL CITY OF IRVINE FURNISHED CABINET, 820A CONTROLLER, AND ALL RELATED EQUIPMENT PER CITY OF IRVINE SPECIFICATIONS. AUXILIARY EQUIPMENT TO INCLUDE OPTICOM RACK. RETURN EXISTING EQUIPMENT TO THE CITY OF NEWPORT BEACH MAINTANANCE YARD. INSTALL 'S I.C. CONDUIT FROM #5 PULL BOX TO NEW CABINET BASE FOR INTERCONNECT CABLE(SEE DETAIL #3, SHEET 9 OF 9). BYPASS #6 PULL BOX. ' INSTALL HYBRID INTERCONNECT CABLE FROM CONTROLLER CABINET AT BIRCH ST. TO NEW CONTROLER CABINET(BY OTHERS) AT VON KARMAN BLVD. APPROX. 2900 FT. INSTALL FIBER INTERCONNECT UNIT (FIU) IN NEW TRAFFIC SIGNAL CONTROLLER CABINET, AND TERMINATE HYBRID CABLE. INSTALL 3" LC. CONDUIT FROM EXISTING #5 PULL BOX TO EXISTING #5 PULL BOX. BYP~SS EXISTING #6 PULLBOX. REVISIONS / 1 14 27 SCALE: 1" = 40' BIRCH ST. STA. 00+00.00 MACARTHUR BLVD. STA. 56+95.72 r·--~·11: ; ____ -L_ __ _ ------------- : \ ; • ' i . ' ' . ' \ ' ' . . . . ' ' ' \ \ " • . ' ' • B\RC\-\ S1. CIT"( N E\t✓PORT OF BEACH MACARTHUR BLVD. Pl.ANS PREPARED BY: "[ffi"' or ,~":,, DRAWN BY: J. ALJRE G ,~ OESIGN!ll 111': ~. GBWlfilt!~ V CHECKtll BY: J. LINEHAN ') l • :I -";-· • -, ---; I,-,,,~ ... ~ ),_.-1. ·~ .< l{ .,. , J.:.-t,,. -..;,.,,-/'•-':.;,:::,, ,,,._, ,_,;; BARR"(" GREENSlEIN R.C.E. NO. OAlE CHECKED BY: D,l.lE 9-16-93 D,l.lE 9-18-93 DAlE 9-16-QJ OAlE 1 14 STA. 0 \.l-1~ zo -o --1+ :C. N <...) t!) ~· ~i (/) INTERCONNECT PLAN MACARTHUR BLVD. 52+00.00 TO GIP NO. CIP-2222 PROJECT NO. 8495-MC 59+00.00 1--------------------------------i SHEET 3 9 CITY OF IRVIMI OF PUBLIC WORKS DEPARTMENT • I • 7 6 5 4 3 2 1 NO. OJ m !BJ DATE SCALE: 1" = 40' 1 14 INSTALL HYBRID 25 PAIR #22, 18 FIBER ( 12 MULTIMODE, 6 SINGLE MODE) INTERCONNECT CABLE IN EXISTING CONDUIT. (REMOVE EXISTING 12 PAIR CABLE WHERE APPLICABLE.) EXISTING #5 PULL BOX . TRIM RISERS AS NECESSARY TO ACCOMMODATE INTERCONNECT CABLE. INSTALL HYBRID INTERCONNECT CABLE FROM CONTROLLER CABINET AT BIRCH ST. TO NEW CONTROLLER CABINET(BY OTHERS) AT VON KARMAN BLVD. APPROX. 2900 FT. REVISIONS ·--····- " ~"\ /' \ \l i / I • / / I :u / I I I I ( CORINTHIAN WAY CORINTIAN AVE. STA. 00+00.00 •· MACARTHUR BLVD. STA. 47+47.69 CITY OF NEWPORT BE.ACH 14 l 0 wO • Zo __J 0 + I..-- 0 -.;;t I-<{ • 2~ (/) --------------------------------·-·---·--···- PlANS PREPARED B'Y: DATE ·tm~ DRAWN B'Y: J. AUit£ 0-16-03 DATE OESIGNED B'Y: a uREDISIEIN 9-15-93 DATE V '. CHECKED BY: ~I UNOWf 9-16-93 I /. (; ., • ..•... ,:-'1:; . .., < u; ~r.-: ... 1z .. 5'-5 {./ I 1<:3 DATE BAAR'( N R.C.E. NO. DATE CHECKED BY: MACARTHUR BLVD. INTERCONNECT PLAN MACARTHUR BLVD. 6,10·-60' 1100' CIP NO. CIP-2222 PROJECT NO. 8495-MC STA. 41 +00.00 TO 52+00.00 ----------------------------'SHEET 4 9 CITY OF IRVIME OF PUBLIC WORKS DEPARTMENT - OJ 7 6 5 4 3 2 1 NO. DATE 1 14 s SCALE: 1'' = 40' 23 2 1 17 \ \ I ' \ \ \ I I 22 28 1 14 17 0 wO • Zo :JO <~----· ' 40 J_Q 3_~ 3_7 36 3_5 34 :,3 I J:2 I .11 - - - - - - --~ /--------· -·· ···---· -· ........ -·· j---·· --· -·-------~----t------------i----------i---- -- ----··------!-··------------l-----------!---------------: ---+--_ =-_;;;_=::::------f---------------------------------+ IO Ot.f) I- INSTALL HYBRID 25 PAIR #22, 18 FIBER (12 MULTIMODE, 6 SINGLE MODE) INTERCONNECT CABLE IN EXISTING CONDUIT. (REMOVE EXISTING 12 PAIR CABLE WHERE APPLICABLE.) . EXISTING #5 PULL BOX. TRIM RISERS AS NECESSARY TO ACCOMMODATE INTERCONNECT CABLE. 3" INTERCONNECT CONDUIT, FROM NEW #6 PULL BOX TO NEW CABINET BASE, TO BE INSTALLED BY OTHERS. INSTALL HYBRID INTERCONNECT CABLE FROM CONTROLLER CABINET AT BIRCH ST. TO NEW CONTROLLER CABINET(BY OTHERS) AT VON KARMAN BLVD. APPROX. 2900 FT. REPLACE BROKEN #5 PULL BOX AND COVER WITH NEW. ALL SWEEPS INTO NEW PULL BOXES SHALL BE 45 DEGREE SCHEDULE 40 PVC ELBOWS. THESE ELBOWS SHALL BE TERMINATED AS FAR APART IN THE PULL BOX AS POSSIBLE AND ORIENTED IN THE DIRECTION OF THE CABLE TO FACILITATE CABLE PULLING. NEW CABINET AND BASE BY OTHERS. INSTALL HYBRID INTERCONNECT CABLE FROM NEW CONTROLLER CABINET (BY OTHERS) AT VON KARMAN BLVD. TO NEW CONTROLLER CABINET AT JAMBOREE ROAD. APPROX. 2050 FT. COIL 100 FEET OF HYBRID INTERCONNECT CABLE IN NEW #6 PULL BOX. CONNECTION TO CABINET BY OTHERS. REPLACE EXISTING #5 PULL BOX LID. REPLACE EXISTING#5 PULL BOX WITH NEW #6 PULL BOX FOR 1.C. CABLE. REPLACE EXISTING 90 DEGREE SWEEPS WITH NEW 45 DEGREE SCHEDULE 40 ELBOWS. THESE ELBOWS SHALL BE TERMINATED AS FAR APART IN THE PULL BOX AS POSSIBLE AND ORIENTED IN THE DIRECTION OF THE CABLE TO FACILITATE CABLE PULLING. REVISIONS CITY NEWPORT OF BEACH MACARTHUR BLVD. STA. 32+25.91 VON KARMAN BLVD. STA. 00+00.00 Pl.ANS PREPARED BY: D,t,T[ ·ff ORAWN BY: J. ALIRE 9-111-93 D,0,T[ DESIGNED BY: a, 111!mlSTEIN 9-111-93 v., D,0,T[ CHECKED SY: J,, UNEHAN 9-16-93 ;!, , , ", .·-.)'O r:r ,· . /,.e-, / ,,~;a ,. , ,< & ;..,_,-/h 1, 'f 5 C,,,.T[ CHECKED BY: BARRY., N R.C.E. NO. 01'11: , I I I VON KARMAN BLVD. INTERCONNECT PLAN MACARTHUR BLVD. <( • ~<( I- (/) CIP NO. CIP-2222 PROJECT NO. 8495-MC STA. .30+00.00 TO 41 +00.00 1------------------------------1 SHEET 5 9 CITY OF IRVIMI OF PUBLIC WORKS DEPARTMENT 1..-------------------------------------.- 7 6 5 4 3 2 1 NO. DATE w zo -o _j . -s SCALE: 1" = 40' I BOWSPRIT STA. 00+00.00 MACARTHUR BLVD. 22+99.26 11 I I I I I . 1-'-- 0 IO o+ 1-0 <( I") •o 2"' -,7_ ., ---··· • -·-·· ---··~···· • :,4 ')\ 22 ~1 l ,:,c, I L~ Q ... -V ~--•m•, 7': -===> .,..-.-• • --:==, . I I ----·. ···---···---t--- -··--··· ---------t-----___ __,_\-4--~-•~-----+-1 ___ ,=s=-___ ::-::::.:.-:: • .,---{--·--------·-----l--~--~L--/. ,::-': --,-------~-~==t-::-=:.--:-=::-_-__ ----~~=-~ ----~-• -----. ~----j-l.==.J•::;:···::::.;:-_;:· ==-==-===cJ I I CITY OF I I NEWPORT BEACH 'f ~ •----·-" ------· --·----------. ___ ,.T _____ -·------_ . ., •. --... =~-.-~--~----! .... ··-----~-~-~ 1 17 MACARTHUR INSTALL HYBRID 25 PAIR #22, 18 FIBER (12 MULTIMODE, 6 SINGLE MODE) INTERCONNECT CABLE IN EXISTING CONDUIT. (REMOVE EXISTING 12 PAIR CABLE WHERE APPLICABLE.) EXISTING #5 PULL BOX. TRIM RISERS AS NECESSARY TO ACCOMMODATE INTERCONNECT CABLE. INSTALL HYBRID INTERCONNECT CABLE FROM NEW CONTROLLER CABINET (BY OTHERS) AT VON KARMAN BLVD. TO NEW CONTROLLER CABINET AT JAMBOREE ROAD. APPROX. 2050 FT. REPLACE EXISTING #5 PULL BOX LID. ----· -----· ---------~-,------ ----~~ -. ------~-~-~-~--- BLVD. 23 2 ! I ! I I i BOWSPRIT DR. Ol!AWN SY: J. AUR[ I I ! I INTERCONNECT PLAN MACARTHUR BLVD. ----- 1 17 w zo -o _j . 0 IO o+ I-00 <:( -.- ~ CIP NO. CIP-2222 PROJECT NO. 8495-MC DESIGNED BY: B, GRfDISTEIN DATE 9-15-93 DATE 0-16-13 STA. 1 8+00.00 TO 30+00.00 -------------------------------1SHEET 6 CHECKED BY: J, LINEHAN DATE CITY OF IRVIME OF 9 REVISIONS BAARY N R.C.E. NO. CHECKED ll'f: PUBLIC WORKS DEPARTMENT ' .. ... . j 7 6 • 5 4 3 2 1 NO. ----T---- CITY NEWPORT OF BEACH 1 17 INSTALL HYBRID 25 PAIR #22, 18 FIBER (12 MULTIMODE, 6 SINGLE MODE) INTERCONNECT CABLE IN EXISTING CONDUIT. (REMOVE EXISTING 12 PAIR CABLE WHERE APPLICABLE.) EXISTING #5 PULL BOX. TRIM RISERS AS NECESSARY TO ACCOMMODATE INTERCONNECT CABLE. INTERCONNECT CONDUIT TO CONTAIN ONLY INTERCONNECT CABLE, PULL ROPE, -#8 COPPER BONDING WIRE, AND D. LC. NECESSARY. EXISTING #6 PULL BOX . TRIM RISERS AS NECESSARY TO ACCOMMODATE INTERCONNECT CABLE. EXISTING INTERCONNECT CABLE TO REMAIN. 's WHERE INSTALL HYBRID INTERCONNECT CABLE FROM NEW CONTROLLER CABINET (BY OTHERS) AT VON KARMAN BLVD. TO NEW CONTROLLER CABINET AT JAMBOREE ROAD. APPROX. 2050 FT. INSTALL HYBRID INTERCONNECT CABLE FROM NEW CONTROLLER CABINET AT JAMBOREE ROAD TO NEW CONTROLLER CABINET AT FAIRCHILD ROAD APPROX. 1900 FT. DATE REVISIONS cl :l!':I!! i SCALE: 1" = 40' JAMBOREE RD. STA. 00+00.00 MACARTHUR BLVD. STA. 14+01 .07 24 25 EXISTING #5 PULL BOX. REPLACE EXISTING 90 DEGREE SWEEPS WITH NEW 45 DEGREE SCHEDULE 40 ELBOWS. THESE ELBOWS SHALL BE TERMINATED AS FAR APART IN THE PULL BOX AS POSSIBLE AND ORIENTED IN THE DIRECTION OF THE CABLE TO FACILITATE CABLE PULLING. INSTALL SEPARATE 3" J.C. CONDUIT CROSSING FOR INTERCONNECT CABLE, AND 45 DEGREE SWEEPS. RETROFIT EXISTING CABINET BASE WITH SEPARATE 3" J.C. CONDUIT FOR INTERCONNECT CABLE FROM EXISTING #6 PULL BOX.(SEE DETAIL "t:.' SHEET 7 OF 9) REMOVE EXISTING CABINET AND INSTALL NEW CITY OF IRVINE FURNISHED CABINET, 820A CONTROLLER, AND ALL EQUIPMENT PER CITY OF IRVINE SPECIFICATIONS. RETURN EQUIPMENT TO IRVINE CORPORATE YARD. REPLACE EXISTING#5 PULL BOX WITH NEW #6 PULL BOX FOR J.C. CABLE. REPLACE EXISTING 90 DEGREE SWEEPS WITH NEW 45 DEGREE SCHEDULE 40 ELBOWS. THESE ELBOWS SHALL BE · TERMINATED AS FAR APART IN THE PULL BOX AS POSSIBLE AND ORIENTED IN THE DIRECTION OF THE CABLE TO FACILITATE CABLE PULLING. PLANS PREPARED BY: ·ff v. / l IJ, -t· I '?, (.. ·~·l _:..· {'./iJ ;, ) • ' . "'.)'-.(: i•~-5 BAAIIY /GREENSTEIN R.C.E. NO. I CRAWN BY: J. AURE DESIGNED BY: ~. CRE£NSitlN CHECKDl BY: ~-!,!MEHAN rzJ7/2.J D/.TE CHECKED BY: CITY NE\NPORT OF BEA,CH 18 1 MACARTHUR DETAIL A (D Contractor shall raise existing cabinet from foundation and notch existing concrete foundation as shown by hatched area. @ Upon installation of the new -:5' conduit, the contractor shall concrete grout the notched area in the foundation. In addition the controller cabinet shall be lowered and resecured on the existing foundation. @ Contractor shall install new 3" conduit. 00 00 AS REQ. Existing traffic controller cabinet Existing concrete 1 foundation AS REQ. = == BLVD. Existing traffic controller cabinet Existing concrete foundation Existing traffic controller cabinet Existing concrete foundation CONTROLLER CABINET FOUNDATION MODIFICATION. [)I.T[ D-18-93 [)I.T[ 9-15-93 MTE g-115-93 MTE FOR INSTALLATION OF NEW 3" CONDUIT INTERCONNECT PLAN MACARTHUR BLVD. CIP NO. CIP-2222 PROJECT NO. 8495-MC STA. 1 9+00.00 TO 8+00.00 1--------------------------------ISHEET 7 9 CITY OF IRVIMI OF PUBLIC WORKS DEPARTMENT - • • • .. • ,. • • ~.----------------------------------, OJ @:D § 7 6 5 4 3 2 1 NO. DATE 1 18 • INSTALL HYBRID 25 PAIR #22, 18 FIBER {12 MULTIMODE, 6 SINGLE MODE) INTERCONNECT CABLE IN EXISTING CONDUIT. (REMOVE EXISTING 12 PAIR CABLE WHERE APPLICABLE.) · EXISTING #5 • PULL BOX. TRIM RISERS AS NECESSARY TO ACCOMMODATE INTERCONNECT CABLE. INSTALL FIBER INTERCONNECT UNIT (FIU) IN EXISTING TRAFFIC SIGNAL CONTROLLER CABINET, AND TERMINATE HYBRID CABLE. INTERCONNECT CONDUIT TO CONTAIN ONLY INTERCONNECT CABLE, PULL ROPE, #8 COPPER BONDING WIRE, AND D. L.C. 's WHERE NECESSARY. INSTALL HYBRID INTERCONNECT CABLE FROM NEW CONTROLLER CABINET AT JAMBOREE ROAD TO NEW CONTROLLER CABINET AT FAIRCHILD ROAD APPROX. 1900 FT. EXISTING #5 PULL BOX. REPLACE EXISTING 90 DEGREE SWEEPS WITH NEW 45 DEGREE SCHDULE 40 ELBOWS. THESE ELBOWS SHALL BE TERMINATED AS FAR APART AS IN THE PULL BOX AS POSSIBLE AND ORIENTED IN THE DIRECTION OF THE CABLE TO FACILITATE CABLE PULLING. INSTALL SEPARATE 3n I.C. CONDUIT CROSSING FOR INTERCONNECT CABLE, AND 45 DEGREE SWEEPS. EXISTING #6 PULL BOX WITH 90 DEGREE SWEEPS. REVISIONS _,'"'-_~·y ~;~\t: .. 11""'1,'v / "'. .....,~...cJ~ ' / FAIRCHILD ST. STA. 00+00.00 MACARTHUR BLVD. STA. 100+00.00 .. ······--··-·~ ' --···· ---·· . .,__ -·------·--------------· ·~---------· --------------- DAAWN B'I': J. ALIRE DES)CNEtl BY: B GREDISJDN CHECKED B'I': J. LINEHAN CHECKED S'f: O,.TE 9-16-93 O,.TE INTERCONNECT PLAN MACARTHUR BLVD. CIP NO. CIP-2222 PROJECT NO. 8495.,..-MC STA. a+oo.oo TO FAIRCHILD 1-------------------------------1 SHEET 8 9 CITY OF IRVIME OF PUBLIC WORKS DEPARTMENT • • • • • • D ■TAIL •1 Dl!TAIL •3 3" CONDUIT TO #6 PULLBOX TYPE "A" SIGN MESSAGE 6'-0" FOR 6' SIGN 8 -0 FOR 8 SIGN ~ 6'-0" FD: B' SIGN ' . --4-• -_o_· ~FOR_s·-s-lG_N __ ,s_·~~ f U-BOL TS TYPE "A" SIGN CONDULET ROADWAY SURFACE/ :::;; :::, :::;; z :::E 24" 5" 12" 3" INTERCONNECT CONDUIT ' ' ' ..... 0, 0, SINGLE PHASE, {-----c:::J---N SECONDARY, 120/240V ---D;;::==:::::;----B=c::,-€'a\ METER 3 WIRE SERVICE --c:k-c:----f---1--F==E3~::::\.:(eY SOCKET USE ONL y IF 240V 7---1 I INTERSECTION LIGHTING __/ u,M UM IA IS REQUIRED. b MAIN ~-----100A 120V-ILLUIA. SIGNS 15A '7 ...ef---------<l7>---J'-+-.---<>7l~120V-SIGNALS a----, CONTACTOR 30A I I I 50A ----+~ ~-+--------------------~~~---~ N I t-t--<f-_..,,,,,....,, ' '-------' 1 ... --1 15A N G 0 METER SOCKET AS REQUIRED BY UTILITY UTILITY TEST BLOCK TYPE Y PHOTOCELL CONTROLS WITH COVER 120V-INTERSECT10N l.,~cl-t~~; LIGHTING ( : 1 N ~ ·--'t-0--.,""""' SER\11CE CABINET ... __ ... PEU SERVICE WIRING DIAGRAM . COMMON SERVICE GROUND ROD " " II " II I I I I I I I 00 U t l I I 11 II t I SERVICE • """'-11 i i o. 3" INTERCONNECT CONDUIT ,: cti:11 ===it"=it"==::1•~• . l UII Ir ti I I ·0 11 I 11 o • 11 I II 11 I I 11. 11 '1111111 II 11 O o 11 l: II II o 1111111011 11 I ll II 11 11 1111111 II 11 • H 11 !I 11 11 • ::·:::11 t1lJ JJ II 11 II II C'C'CC'"1 ,.tl :: 11 1: I} ~--------..-., \\ II " ti 0 I ,; o · ., • 2"C TO POWER~:::_-:::: ..,0 .---~~~~~~=====1r==11===::-- COMPANY SER~~ICE O _::::::::::::::. :..:..-_:..=::-_:..:..:::..:..__r, D ,,,, ~---------------------------,✓ POINT ~----------c------------:-- 3 • INTERCONNECT ,..,.,_/1.._/--..,..~w-~..,.. TYPICAL FIELD WIRING CONDUIT (3") TO CONTROLLER CABINET __J~ • Li) IX) ~ ILLUMINATED STREET NAME SIGN MAST ARM CONTROLLER CABINET & MODIFIED TYPE JI SERVICE BLK. WHT. 15 amp D ■TAIL •2 Duplex Outlet .---------------------(No G.F.I.) -.,___... ____________________ Cabinet Light 15 amp ----------------Detector Power ,--------Stop Time Power ~---A.C.-Controller r---------------------------------------~ ' I i cont. st 10A i AUXILIARY PANEL Main Signal I Auto o o ON • L' .,._,_Rs1-----•---~~.::..:.--, I 1 • Controller Power . 1 50A Breaker Lfl9!?b _____ -{1.: _________ !.DIT ________ J Aux. Equipment Voltage • Surge Protection Equi . ••••••• Gnd. Bus. A.C. Common I······ ·I Bus On (Pwr. on T.B.) Auto r------------------------ - -------------------~ t ON I i Signal OFF '--!-a' ' I Light • Flesh I I I I I I POLICE PANEL ~------------------------------------------L ________ J ____ Stop Time Out '--------------Flash Relay '----f----..,.._ ___________ Flash Power ..,_ __________ A.C.+Lights .----~ MC 60A .....,_~-Min. FIU II II II II II II II II II II 11 II 11 II II 11 11 II 11 11 11 II ~H :: l: D ■TAIL •4 CE~ ~IAN ISLAND POLE LOCATION CODE ( EXACT LOCATION BY ENGINEER IN THE FIELD ) Dl!TAIL •7 [QJ I I I J FIU --------------------- INTERCONNECT TERMINATION BLOCK TELEMETRY PANEL DETECTOR--.J--1 PANEL .,__,_, LOOP PANEL -1--, LOOP PANEL--i-, a 0 o· . . 3" INTERCONNECT CONDUIT 3" INTERCONNECT CONDUIT D " " " " o 11 ° ·" " • TYPE "p" CABINET 1 ;,," C, TO POWER PANEL ALL CONDUITS PLACED TO REAR OF CONTROLLER CABINET LOAD BAY 2" MAX. 18" ABOVE GRADE FOR TYPE "p" FOUNDATION (TYPICAL) CABINET FOUNDATION 8. 7 5" FIU TO OTHER SIGN LIGHT BALLASTS AS REQ'D TYPE 90 CONTROLLER CABINET WIRING LEFT VIEW SIDE VIEW INSIDE VIEW FIBER INTERCONNECT UNIT (FIU) DATE NUMBER DATE INITIALS DESCRIPTION A Dl!TAIL •S TWISTED PAIR JUMPERS WHT.> ,--------,'-+-------ORG. COMMUNICATIONS WHT.> ,---/-,'---------GRN. DATA ©©ffiffi©©©©ffi©©ffi©©©©©ffi 1 2 3 4 5 6 7 8 9 ½ ½A½A½A.,,,,u,©©©©©©©©©©©©©©©© ,__,__._.,,__,_-l ------- B0000 BINDER COLOR FIRST (TYPICAL ALL PAIRS) ~ ~ TWISTED PAIRS (2 PAIRS) OUT TO THE FIELD TRAFFIC SIGNAL INTERCONNECT BLOCK (TSIB) Dl!TAIL •• PHOTO-ELECTRIC CELL INTERGRAL TO SIGN FIXTURE SECONDARY TO FLOUR. LAMP 1 BALLAST SIGNAL & LIGHTING SERVICE CIRCUIT BREAKER & MAIN SWITCH BOX SECONDARY METER TO FLOUR. LAMP ! SERVICE BALLAST ,. .. . . .. . 120 V. BRANCH CIRCUIT SIGNAL & SIGN I 7 COMMON ,.__,===1=Ji.----------j~--_...c:::_ __ _______.!,~===;57I I CABINET _J PULLBOX--~ CONTROLLER #14 AWG SIGN CIRCUIT ILLUMINATED MAST ARM SIGN WIRING DIAGRAM CIP No. 2222 PROJECT NO. 8495-MC SHEET 9 ~ DESIGNED BY: B. GREENSTEIN 9-16-93 CITY OF IRVINE IL ___________________________ ...1. _ _J __ L _ _L ______________ L_ _ _JL_ ____ sc_A_LE-:N_o_N_E ___ __JL_ ________ _,Jl....-__ ___:.P..::U:.::B:.::L:.:IC_W.:.:..:::.OR:..:.:K~S;._;;;D.;;;E~PA..;;,R~T.;.;;M.;;;,EN;..;.T;..,_ ___ "-___ ... · OF 9