Loading...
HomeMy WebLinkAboutH_5240_SNEWPORT BAY HARBOR AND EAST JETTY REPAIRS WEST N 659 500 + + N 659 000 + + I 0 0 0 C"l I 0 0 If) 0 r--(X) v v (X) (X) 0 :i: If) ~ (X) I z v 1"1' (X) r w w w GENERAL PLAN SCALE, 1,5000 INDEX TO CONTRACT DRAWINGS FILE NO. TITLE SHEET NO. LEGEND: H-700 GENERAL PLAN, VICINITY MAP, CONTRACTOR'S AREA, ANO INOEX TO CONTRACT ORAWINGS H-701 PLANS ANO SECTIONS 2 H-726 CONDITION SURVEY 3 300 200 100 o SCALE' 1'5000 + SIA. l•OJO 0 I g "' v (X) w REPNR AREAS FOR REPLACEMENT AND RESETTING OF ARMOR STONE CONTROLLED LOW-STRENGTH MATERIAL FILL N NOTES: 300 METERS CONTRACTOR AREAS NOT TO SCALE .., > n 0 0 c> <" I '. \ ••tk -~ CAI.FORNIA •• ' VICINITY MAP NOT TO SCALE 1. COORDINATES ARE CALIFORNIA LAMBERT ZONE VI <NAD 83>. 2. ALL DIMENSIONS GIVEN ARE IN METERS UNLESS OTHERWISE INDICATED. PRO.£CT LOCATION i 0 ........... ; ......... . i -5 ···········1·········· ·/() ·30 ·25 ·20 15 /() ·5 SECTION 'A-A' SCALEt 11300 TYPICAL WEST JETTY REPAIR SECTION STA 0•241 TO STA 0•457 ·/() ·5 0 SECTION 'B-8' SCALE! 1:300 5 TYPICAL WEST JETTY REPAIR SECTION STA 0•457 TO STA 0•847 /() 15 ·/() 20 15 /() ·5 -IO'+---+--;..--+--+--;..--+--+--i-----4---1-·/() ~ ~ ~ ~ -IO -5 0 5 IO 5 20 SECTION ·c-c· SCAlE, 11300 TYPICAL WEST JETTY REPAIR SECTION HEAD SECTION LEGEND: NB-9-92 3-1/2" BRASS DISK NB-11-92 3·1/2" BRASS DISK PROPOSED PROJECT LIMITS N 659 439.52 E 1 848 592.39 ELEV. 6.10 MLLW N 659 461.40 E 1848 887.15 ELEV. 3.49 MLLW •'l ' GRO~o>/ I.P~.,~\.-r ,/ SEE NOTE 5 ~ .. _ .. / TOE <APPROX> GRAPHIC SCALE: 100 50 0 100 SC.11.E• l•JOOO 10 5 0 10 sow 1•300 2 0 2 SC.11.E• 1•60 N s1"· o·sio .. -.... ~ l Vl' --:: '' v,; ...,, ,-, ,. : i: rTli ' . ' \! i: TEMPORARY WORK AREA <BET. EAST JETTY ANO ANO FIRST ROW OF B-B-0 PITS, SEE NOTE 7) NAVIGATION AID STA. 1•030 SECTION 'D-D' SCALE, h60 TYPICAL EAST JETTY REPAIR SECTION AND CLSM PLACEMENT DETAIL STA 0•520 TO STA 0•732 CLSM PLACEMENT DET~L NOTES 1. REMOVE All DEBRIS/ASPHALT/CONCRETE FROM EXISTING ACCESS/INSPECTION PORTS. ACCESS/INSPECTION PORT IS APPROXIMATELY 0.6 M SQUARE. THERE ARE 35 ACCESS/INSPECTION PORTS ALONG JETTY. 2. FILL VOID WITH CLSM (CONTROLLED LOW STRENGTH MATERIAL) TO TOP OF EXISTING SLABS. 3. AFTER "INITIAL SET", EXCAVATE CLSM AS INDICATED ABOVE. 5 4 J [;; ; 2 ~ 4. AFTER A PERIOD OF 72 HOURS, FILL THE EXCAVATED ACCESS/INSPECTION PORT WITH STRUCTURAi. CONCRETE. 5. AT ALL TIMES CLSM AND STRUCTURAL CONCRETE ARE TO BE CURED AND PROTECTED AS ANY PORTLAND CEMENT CONCRETE. EXCAVATED CLSM, SURF ACE WILL BE PREPARED TO RECEIVE STRUCTURAL CONCRETE BY REMOVAL OF CURING COMPOUNDS ANO/OR OTHER DELETERIOUS SUBSTANCES TO THE SATISFACTION OF THE CONTRACTING OFFICERS REPRESENTATIVE. • ·~···········1···········~···········1··· ' I I • 15 ........... , ....... . I ! l I IO ··········+ ........... -!. ··•·· ---· ;. ·-·--···· !--·······)·········)·········)········ ··1,,_ ---···!···········l······-···· : : : • i,_ •.:,_ i StAWARD i i i j i ; : ···••J ttt·t;·:-:r··''tJ··:::i~•······ ! ! 1----: l'5 I l ! I i 15 IO 5 0 ·5 •5 ····•·•···-r·········r········· ········1········ rstE"·r,nr········r·········r-·······r······•·· ·IO+--i---+--+---i---+---i---+--+---,i---'-----1-·IO ·30 ·25 ·20 ·IS ·IO -5 0 5 SECTION 'E-E' SCALE1 1t300 IO TYPICAL EAST JETTY REPAIR SECTION HEAD SECTION 15 20 25 [;; I GENERAL PLAN GENERAL NOTES: SCALE• 1•3000 200 METERS 20 METERS 4 METERS 1. VERTICAL DATUM IS MEAN LOWER LOW WATER. 2. ALL DIMENSIONS ARE SHOWN IN METERS UNLESS OTHERWISE INDICATED. 3. ADD NEW "A-13.6" ARMOR STONE AS NEEDED ANO RESET EXISTING STONE TO MATCH EXISTING SLOPE ANO ELEVATION. 4. ADD NEW "A-2.7" ARMOR STONE AS NEEDED AND RESET EXISTING STONE TO MATCH EXISTING SLOPE ANO ELEVATION. 5. REPAIR WORK STA. 0•241 -0•457 TO BE AWARDED AS CONTRACT OPTION ITEM. REMOVE EXISTING CONCRETE REMNANTS. ADD NEW "A-2.7" ARMOR STONE AS NEEDED AND RESET EXISTING STONE TO MATCH EXISTING SLOPE AND ELEVATION. 6. REPAIR WORK STA. 0•457 -0•518 TO BE AWARDED AS CONTRACT OPTION ITEM. ADD NEW "A-13.6" ARMOR STONE AS NEEDED AND RESET EXISTING STONE TO MATCH EXISTING SLOPE AND ELEVATION. 7. CONTRACTOR'S OFFICE AREA, MOORING AREA, AND TEMPORARY WORK AREAS ARE AS SHOWN. THE CONTRACTOR MAY ELECT TO OBTAIN Al TERNATE LOCATIONS FOR AN OFFICE AREA, MOORING AREA, OR TEMPORARY WORK AREA ON HIS OWN ACCORD. Vl I z 0 iii 5 w i!l "" a .. "' g ~ u 3i ~ t ~ ;:. ;:. <D I'" e ! j I! d~ ~ ! VALUE ENGINEERiNG PAYS !" M i i ~ ~ + + + + + + + + + + + + + + + + + + + SAFETY PAYS + N. 660.JOO + N. 660.000 + N. 659,700 + N. 659.400 + N. 659,100 + N. 658,800 !" N RATIO h3000 100 200 300 DEPTHS ARE MEAN LOWER LOW WATER NOTE, 1. SOUNDINGS mo ELEVATIONS, IN METERS, INDICATE THE GENERAL CONDITIONS EXISTING ONLY AT THE TIME OF SURVEY -APRIL 30, MAY 1, 6-8, 1996. 2. CONTOURS ARE BASED ON PLOTTED SURVEY DATA mo MAY NOT ACCURATELY INOlCATE CONDITIONS BETWEEN THE PLOTTED ELEVATIONS. 3. COORDINATES ARE CALIFORNIA LAMBERT ZONE VI. (NAO 1983). 4. SOLINDINGS LOCATED BY DIFFERENTIAL GPS SYSTEM. 5. SOUNDINGS ARE SHOWN TO THE NEAAEST DECIMETER mo ALL NON-WATER ELEVATIONS ARE TO THE NEAREST CENTIMETER. 6. ALL STRUCTURES SHOWN ARE APPROXIMATE. ~ I !