Loading...
HomeMy WebLinkAboutS2022-0097 - MiscACOUSTICAL ENGINEERING ANALYSIS 1209 Santiago Dr. Newport Beach, CA 92660 May 29, 2024 YANCHAR DESIGN & CONSULTING GROUP 26741 Portola Parkway, Suite 1 E, Foothill Ranch, CA 92610 Tel: 949.770.6601 Fax: 949.770.6575 E-mail: info@yanchardesign.com 1209 Santiago Dr. May 29 2024 1.0 Introduction At the request of Mata Constructions, Yanchar Design & Consulting Group has completed field measurements and an acoustical analysis of the pool equipment located at 1209 Santiago Dr., Newport Beach, CA. 2.0 Project Description The property is a single-family residence. The pool equipment is located approximately 3 feet from the property line to the northwest The nearest property to the northwest is also a single-family residence. The properties are separated by a 6-foot concrete wall. The City of Newport Beach requires a sound test by an acoustical engineer is required to demonstrate that the noise level from the pool or spa pump is less than 55 dBA at the property line. NBMC10.26. 025. YANCHAR DESIGN & CONSULTING GROUP 2 1209 Santiago Dr. May 29, 2024 2.0 Field Measurements Measurements were made at the site on May 29, 2024 to determine the sound level of the pool equipment. The ambient noise level at the property was dominated by aircraft overflights. The sound level of the pool equipment measured at the northwestern property line was 52.3 dBA. Therefore, the equipment is in compliance with the requirements of the City of Newport Beach Municipal Code. A Soft dB Piccolo -II Integrating Sound Level Meter, Serial Number P0219050803 and CEL Instruments Model CEL-284/2 Calibrator, Serial Number 4/09023134, were used for the measurements. Respectfully submitted, Yanchar Design & Consulting Group Carl J. Yanchar President YANCHAR DESIGN & CONSULTING GROUP 3 1209 Santiago Dr. May 29, 2024 ' F ^` s 1'j 'E{�k •Ek y xr.wn O i ✓ f 2 — 3 Is S gi } 4 NA, 4.Kk *Y ; 5 5 S F 2x4 ,nrrx.vvnk tlII 8 t 'yE R., day ✓,€{ s f •. ATM` _ r PROJECT VICINITY PROJECT SITE YANCHAR DESIGN & CONSULTING GROUP 4 Continuous Inspection & Materials Testing & A SOUTHWEST IVIV& WWV'W1W'W1WA1W II1fipcc t1011 c' 'Yest g, 111(. 441 Commercial Way, La Habra, CA 90631-6165 (5621941-2990 (71 1)526-8441 FAX (562)946 0026 FIELD DATA ON TEST SPECIMENS --- ASTM C31, C138, C143, C172, C173, C231, C1064 --- CONCRETE: MORTAR: SHOTCRETE: X CORES: GUNITE: ADDRESS: 1209 SANTIAGO, NEWPORT BEACH JOB #: DATE: 12/16/2022 JOB NAME: PERMIT M S2022-0007 ISSUED BY: NEWPORT BEACH ARCHITECT: ENGINEER: POOL ENGINEERING INC. CONTRACTOR: SUB: FARING ENGINEERING LOCATION IN STRUCTURE: POOL WALLS TRACT: PHASE: LOT #: CONCRETE SUPPLIER: HOLIDAY PLANT: # MIX #: 34523 TYPE OF CEMENT: V ADMIXTURE: TICKET M 7245539 SLUMP: 2.00 in. WATER ADDED: 0 gal. AIR TEMP: 60 F CONCRETE TEMP: 0 F MIXING TIME: 60 min. TIME CAST: 09:30 DATE CAST: 11/17/2022 RECEIVED AT LAB: 11/18/2022 SPECIMENS MADE BY: SPECIFIED PSI @ 28 Days: 4500 LAB #: 223332 CLIENT: CHRIS WHELAN INSP. TESTING INFORMATION: SAMPLE IDENTIFICATION: 2351860 2351861 2351862 AGE DAYS: 28 28 28 DATE TEST: 12/15/2022 12/15/2022 12/15/2022 SIZE (in.): Height X Diameter 8.000 X 4.000 8.000 X 4.000 8.000 X 4.000 AREA (in.A2): 12.57 12.57 12.57 CRUSH LOAD (Ibs.): 71200 73870 76450 COMPRESSIVE STRENGTH (psi.): 5660 5880 6080 HEIGHT -DIAMETER RATIO: CORRECTION FACTOR: CORRECTED STRENGTH (psi.): BREAK TYPE: V IV IV C.T.M. USED: Forney96 Forney96 Forney96 REMARKS: ASTM C39, C174, C192, C470, C617, C42 COMPLIES: X DOES NOT COMPLY: FOR INFORMATION: THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC. SAMPLES CAST BY OTHERS: NOTICE:These test results are from samples cast by inspectors or technicians not employed by our firm. They were either delivered to our laboratory or picked up by our driver. We will accept no responsibility for the inspection made on the jobsite by the inspector, furthermore we do not take responsibility for any information on this report other than the strength as tested and reported. ASTM C39 BREAKS: I=CONE - II=CONE AND SPLIT - RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING ZAFAR AHME PRINCIPAL INEER III=COLUMNAR - IV=SHEAR - V=SIDE FRACTURES - VI=POINTED J�-w POJ',J CITY OF NEWPORT BEACH t COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION r't,.,nog"' 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658 www.newoortbeachca.Dov 1 (949) 644-3200 SPECIAL INSPECTION REPORT Project Address:1209 Santiago Permit Number: S2022-0097 Inspection Type (s): Reinforced Concrete Inspection Date (s): 11/17/2022 ElPeriodic FVContinuous Describe Inspection, Including Location(s): Observed the placement of 60 cubic yards of 4500 psi shotcrete, Holiday mix design 34523 for pool and spa. All rebar and hardware was securely tied in place at time of pour, and all required clearances were maintained. three 4"x8" cylinders were taken from load 4 ticket # 7245539 Slump = 2.5" List Tests Made: Total Inspection Time Each Day: Date: 111 /17/2022 Hours: 4 Comments: To the best of m knowledge, the work inspected was in accordance with the Building Division approved design drawings, specifications ano�applicable workmanship provisions of the U.B.C. except as noted above. Special Inspector Signature: Date: ��<<✓{:��! -- 11/17/2022 Print Full Name: Newport Beach Registration No.: Christopher J. Whelan NB-0661 Speciallnmpec[ionXeport 08/25/2015 CHRIS WHELAN ,t I �1SPECTI(DNS 43583 Anatra Place, Indio, CA. 92203 (949)289-5039