Loading...
HomeMy WebLinkAboutThirtieth Street Architects, Inc. (PA2005-158) 2961 Cliff DriveCITY OF NEWPORT BEACH PLANNING COMMISSION STAFF REPORT Agenda Item No. 3 March 23, 2006 TO: PLANNING COMMISSION FROM: Planning Department Jaime Murillo, Associate Planner j murillo(cbcity. newport- beach. ca. us (949) 644 -3209 SUBJECT: 2961 Cliff Drive General Plan Amendment No. 2005 -003 and Parcel Map No. 2005 -035 (PA 2005 -158) APPLICANT: Thirtieth Street Architects, Inc. ISSUE Should the City approve a General Plan Amendment and Parcel Map to allow the subdivision of an existing single- family lot into two single - family parcels? The applicant requests the approval of an amendment to the Land Use'Element of the General Plan to allow the subdivision of a property located within Statistical Area H -2, where subdivisions are currently prohibited. RECOMMENDATION Staff recommends that the Planning Commission recommend approval of General Plan Amendment No. 2005 -003 and Tentative Parcel Map No. 2005 -035 to the City Council by adopting the attached draft resolution. PROJECT DESCRIPTION Site Description The lot is currently developed with a single- family dwelling, approximately 2,123 square feet in size, which was constructed in 1947. To the north, across Cliff Drive, are single - family dwellings. To the southeast is a single - family dwelling, developed in a similar manner as the existing subject property. To the south, across the partially unimproved Avon Street, are retail/commercial office uses and an automobile dealership. To the northwest, across Santa Ana. Avenue, are additional single - family dwellings. 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 3 of 15 The subject lot is 33,193 square feet in size. The northeasterly 1/3 portion of the lot is relatively flat and developed with the existing dwelling. The southwesterly 2/3 portion of the lot consists of sloping undeveloped terrain, primarily consisting of dirt, weeds, shrubs and grass. A significant depression in the slope occurs immediately south of the existing dwelling structure, in which the slope exceeds a 2:1 ratio, however, a majority of the site (91 %) maintains a slope of less that 2:1 (Exhibit 2 - Slope Analysis). Project Description The applicant is proposing to demolish the existing single - family residence and subdivide the existing lot into two parcels for the development of two separate single - family residences. The applicant has designed the parcels to comply with all applicable requirements of the Zoning Code and applicable provisions of the Subdivision Map Act and the City's Subdivision Code (Title 19). (Exhibit 3 - Tentative Parcel Map) Parcel 1 Parcel 1 is the northeasterly of the two parcels and is proposed to be 14,767 square feet in area. The parcel will have Cliff Drive as its primary street frontage and it will take vehicular access from Cliff Drive. The parcel will maintain the minimum required 20 -foot front yard setback from Cliff Drive, 4 -foot side yard setbacks, and 10 -foot rear yard setback. The resulting buildable area of the parcel is 11,204 square feet allowing for a potential structure with 22,408 square feet of gross floor area. Parcel 2 Parcel 2 is the southwesterly of the two parcels and is proposed to be 18,426 square feet in area. The parcel will have Santa Ana Avenue as its primary street frontage and it will take vehicular access from Santa Ana Avenue. This parcel will maintain the minimum required 20 -foot front yard setback from Santa Ana Avenue, 4 -foot side yard setbacks, and 10 -foot rear yard setback. The resulting buildable area of Parcel 2 is 12,777 square feet allowing for a potential structure with 25,554 square feet of gross floor area. No vehicular access to Avon Street is proposed and is prohibited by the Land Use Element. Architectural Plans Generally, the approval of the General Plan Amendment and Parcel Map would review the suitability and design of the proposed parcels; however, specific structures are typically not required or reviewed. However, the applicant has designed two custom residences, which the property owner is committed to constructing and intends to submit plans for building permits upon receiving approval of the subdivision. Detailed architectural plans, a conceptual grading plan, and landscape plans have been prepared and attached as Exhibit 4 and serve the purpose of illustrating that the site is physically suitable for the type and density of the proposed development. In addition to those plans, 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 4 of 15 the applicant has prepared preliminary geotechnical investigations and preliminary hydrology /hydraulic report for the site, to demonstrate that the property is safe and suitable for the development of two separate dwelling units (Exhibits 5 and 6). The residences. have been designed with the hope of being compatible with the surrounding neighborhood and to minimize view impacts to the maximum extent possible, and therefore a condition of approval has be incorporated requiring the final design of the dwellings to be within substantial compliance with the architectural plans stamped with the date of approval. The residence on the upper lot. is proposed to be approximately 9,500 square feet and the residence on the lower parcel is proposed to be approximately 8,800 square feet. The lower residence in particular, has been designed into the hillside using the natural topography of the parcel, with a majority of the building mass below the curb line of Santa Ana Avenue. In addition, the lower residence is proposed to include elements of a sod roof to visually minimize and soften the mass and aesthetics of the proposed residence as viewed form the neighboring homes. The two residences have been carefully designed to follow the natural contours of the sloping lot, and therefore should easily comply with the 24 -foot height limit as measured from natural grade. Grade As mentioned, a detailed conceptual grading plan has been prepared for the project and incorporated into the tentative parcel map. Section 20.65.030(B)(1) of the Zoning Code states that for the propose of measuring height, the grade shall be the unaltered natural vertical location of the ground surface unless , `At the time of subdivision, the City has approved a grading plan or map, under which circumstances grade shafl be finished grade as shown on the plan or map so approved ". However, the applicant prepared the grading plan to illustrate that the site is physically suitable for the proposed development using the natural slope of the property, and not for the purposes of establishing a new grade. Therefore, to ensure that future dwelling units are constructed utilizing the existing topography of the property for the purposes of measuring height,. a condition as been included requiring the height to be measured from the natural grade as depicted on the topographic survey prepared by Myers & Associates on August 31, 2005 (Exhibit 7). BACKGROUND The existing lot was approved for subdivision (Resubdivision No. 707) into four parcels by the Planning Commission in 1982, prior to the current prohibition of subdivisions. The Planning Commission's decision was subsequently overruled by the City Council with the project being denied. The project proposed under Resubdivision No. 707 would have created four parcels ranging in size from 6,577 square feet to 8,077 square feet, with three parcels taking vehicular access off Santa Ana Avenue and one parcel taking access.off Avon Street. Additionally, land dedication and substantial improvements were required, connecting 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 5 of 15 Avon Street to Santa Ana Avenue. Several residents of the community expressed opposition to the project; comments raised specifically related to the higher density resulting on the site, opposition to the extension of Avon Street due to increased traffic, potential traffic impacts resulting from the proposed driveway access onto the narrow Santa Ana Avenue, obstruction of views, hydrology, and soil stability. It appears that for these reasons, the City Council denied the project. ANALYSIS General Plan- Land Use Element The Land Use Element of the General Plan sets forth objectives, policies and limitations for development in the City and designates the general distribution and location of land uses and residential and commercial densities. The Land Use Element designates the site as Single - Family Detached. The proposed subdivision is consistent with this designation; however, the project site is located in Sub -Area 1 of Statistical Area H2 (Newport Heights), which states that, "No subdivision which will result in additional dwelling units is permitted... ".Therefore, this subject General Plan Amendment is required to permit the proposed subdivision and increase the development allocation for the area by one additional unit. The revised language, should this amendment be approved, is proposed to read as follows: Newport Heights Area (Statistical Area H2) 1. Newport Heights. This area is located northerly of the Mariner's Mile Specific Plan area between Santa Ana Avenue and Irvine Avenue. The area is designated predominantly for Single Family Detached development, with the area near 16th Street and Tustin Avenue shown for Two - Family Residential and Multi- Family Residential land use. No subdivision which will result in additional dwelling units is permitted, except for the site at 'n tz„ 2961 Cliff Drive, which may be subdivided to create one additional parcel with a minimum lot area of 14,500 square feet. A minimum of 2, 000 sq. ft. of buildable lot area is required for duplex development in the Two Family area, and one unit is allowed for.each 2,178 sq. ft. of buildable lot area in the Multi- Family Residential area. The area is allocated a maximum of X90 791 dwelling units. Residential access from Avon Street is prohibited, except for lots where no access is available from either Cliff Drive or Santa Ana Avenue. 'Note: The previous exception granted for the subdivision of 2919 Cliff Drive is proposed to be removed since the property was subdivided into four separate single- family homes (2907, 2911, 2915, and 2919 Cliff Drive). Staff believes the neighborhood controversy surrounding the requested four parcel subdivision of this subject property in 1982, as well as other similar requests on adjacent 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 6 of 15 lots, may have contributed to the prohibition of subdivisions in this particular Statistical Sub -Area, which was included as part of the 1988 update to the Land Use Element. The proposed subdivision to create two separate single - family lots is compatible with the neighborhood because the resulting density of the project (2.6 d.u. /acre) is substantially less than the surrounding lots in the community and will not cause the area to increase in average density. Additionally, the existing topography of the lot naturally divides the property into two building pad levels and is conducive to the construction of two structures, unlike previous attempts to subdivide this property which attempted to divide the property into four separate parcels. The Land Use Element has 12 general policies to guide consideration of the potential amendments. During its review, staff found that Policy D should be considered. Land Use Element Policy D states: D. The siting of new buildings and structures shall be controlled and regulated to ensure, to the extent practical, the preservation of public views, the preservation of unique natural resources, and to minimize the alteration of natural landforms along bluffs and cliffs. Unique natural resources do not exist on the site and the sloping property is not a natural landform requiring protection as identified in the Implementation Measures of Policy D. Implementation Measure D-1 identifies natural coastal bluffs as a significant scenic and environmental resource, and as defined in Policy D, a "coastal bluff' is any natural landform having an average slope of 26.6 degrees (50 %) or greater, with a vertical rise of 25 feet or greater. A slope analysis has been performed on the site and concludes that the site does not meet the definition of a coastal bluff as defined per this policy because only 9% of the property consists of a slope 2:1 or greater. Additionally, as discussed later in detail in the Coastal Resource Protection section of this report, the site does not meet the Coastal Land Use. Plan definition of a bluff, or coastal bluff, because the topography of the slope does not consist of a headland, nor does it consist of a precipitous or steep cliff face, and it is not subject to marine erosion. Therefore the specific development requirements of Implementation Measure D-2, related to grading and blufftop setbacks for structures located on coastal bluffs, do not apply. And as stated previously, the existing lot can be completely developed with one large single - family home with no restrictions beyond the minimum development standards. The subject site is not identified in the City's Coastal Land Use Program as a public view point or to provide public coastal views through the site, nor is Cliff Drive and Santa Ana Avenue identified as a coastal view road requiring public view protection. Private views from adjacent residences may be affected, and Santa Ana Avenue does currently afford a coastal view, however the City does not have any private view protection ordinances or policies. As mentioned, the lower residence has been designed into the hillside using the natural topography of the parcel, maintaining a 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 7 of 15 majority of the building mass below the Santa Ana Avenue curb line and preserving the views from Santa Ana Avenue. Additionally, the applicant held a community workshop on September 22, 2005 to discuss the proposed development with neighbors, in which several neighbors discussed concerns related to view impacts. The applicant then substantially modified the design of the upper house by reducing the overall height and mass of the proposed residence by reducing the second floor and shifting the second floor back closer to Cliff Drive, preserving the existing views to the maximum extent possible. Therefore, the project as designed does not impact any public views and minimizes potential private view impacts to the greatest extent possible. Implementation Measure D -3 states that no structures shall be permitted in areas of geologic hazard where natural geologic processes can pose a threat to the public health, safety, and welfare. These areas of hazard contain earthquake faults, existing or potential landslides, areas with expansive or collapsible soils, excessive settlement and subsidence, and areas subject to potential erosion and siltation. Preliminary Geotechnical Investigations have been prepared. for both of the proposed residences and concluded that the proposed residential developments are feasible and safe from a geotechnical viewpoint, provided it is constructed with the conclusions and recommendations provided within the reports (Exhibit 5). No active faults were observed or previously mapped through the site, and fault rupture across the property is not anticipated. No slumps or landslips that may impact the site were noted in the study area or on any reviewed referenced publications. And the lack of groundwater in the upper 50 feet of the subject site results in the potential for liquefaction to be considered remote. Additionally, it was concluded that the development of the site will not geotechnically adversely impact adjoining properties provided the recommendations of the report are implemented in, design, construction, and maintenance. Therefore, for the reasons discussed above, this project is consistent with this Policy D and its implementation measures. Local Coastal Program The Coastal Land Use Plan of the Local Coastal Program (LCP) sets forth goals, objectives, and policies that govern the use of land and water in the coastal zone within the City and addresses land use and development, public access and recreation, and coastal resource protection. Currently, the project site is. designated for Very Low Density Residential (RVL 2.6 - 4.5 DU /AC). The proposed subdivision is consistent with this designation as the proposed project density is 2.6 d.u. /acre. During its review, staff found that several of the policies contained within the LCP should be considered and are discussed below: Location of New Development 2.2.1 -1 Continue to allow redevelopment and infill development within and adjacent to the existing developed areas in the coastal zone subject to the density 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 8 of 15 and intensity limits and resource protection policies of the Coastal Land Use Plan. 2.2.1 -2 Require new development be located in areas with adequate public services or in areas that are capable of having public services extended or expanded without significant adverse effects on coastal resources. The subject property is located within an existing developed area of the Coastal Zone and its current density is well below the maximum density limit established for the RVL designation of the Coastal Land Use Plan. Redevelopment of the site into two separate parcels will continue to remain below the density limit. Public services and infrastructure are available to serve the proposed development, and all applicable improvements required by Section 19.28 (Subdivision Improvements) of the Subdivision Code are to be satisfied by the applicant. Residential Development 2.7 -1. Continue to maintain appropriate setbacks and density, floor area, and height limits for residential development to protect the character of established neighborhoods and to protect coastal access and coastal resources. The residential structures proposed to be constructed within the subject parcels must comply with all applicable R -1 development regulations of the City's Zoning Code, specifically pertaining to setbacks, floor area, and height limitations, to insure design compatibility with the surrounding neighborhood. Hazards and Protective Devices 2.8.1 -1. Review all applications for new development to determine potential threats from coastal and other hazards. 2.8.1 -2. Design and site new developmenf to avoid hazardous areas and minimize risks to life and property from coastal and other hazards. 2.8.1 -3. Design land divisions, including lot line adjustments, to avoid hazardous areas and minimize risks to life and property from coastal and other hazards. 2.8.1 -4. Require new development to assure stability and structural integrity, and neither create nor contribute significantly to erosion, geologic instability, or destruction of the site or surrounding area or in any way require the construction of protective devices that would substantially alter natural landforms along bluffs and cliffs. 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 9 of 15 2.8.7 -1. Require new development to provide adequate drainage and erosion control facilities that convey site drainage in a non - erosive manner in order to minimize hazards resulting from increased runoff, erosion and other hydrologic impacts to streams. 2.8.7 -2. Require applications for new development, where applicable [i.e., in areas of known or potential geologic or seismic hazards], to include a geologic/soilslgeotechnical study that identifies any geologic hazards affecting the proposed project site, any necessary mitigation measures, and contains a statement that the project site is suitable for the proposed development and that the development will be safe from geologic hazard. Require such reports to be signed by a licensed Certified Engineering Geologist or Geotechnical Engineer and subject to review and approval by the City. As previously discussed in the Land Use Element analysis, Preliminary Geotechnical Investigations have been prepared for both of the proposed residences and concluded that the proposed residential developments are feasible and safe from a geotechnical viewpoint. Additionally, the study noted that geologic hazards were not observed or anticipated on the site. A Preliminary Hydrology /Hydraulic Report was prepared for the proposed project by Gilbert Engineering & Associates, Inc., to determine the storm water discharges generated within the local drainage areas and to demonstrate that the storm water and flood protection goals are met. The report concludes that the drainage patterns or direction of flow did not change from the existing conditions to the proposed development. However, the discharge will improve from uncontrolled sheet flow down the slope to a controlled concentrated flow through the V- ditches, ultimately improving the drainage. Additionally, the proposed drainage system (designed to a 10 -year frequency storm) is adequate to transport the drainage off site and that in the event of a 100 year frequency storm, there should be no significant damage to the proposed structures. Upon submitting final design drawings for the construction of the proposed residences, new geotechnical and hydrological reports will be required to be reviewed and approved by the City, additionally a Water Quality Management Plan will be required to ensure that the project complies with the City's water quality and on -site storm runoff retention requirements. Therefore, it is staffs belief that the project is consistent with these policies. Coastal Resource Protection Policies 4.4.1 -1 through 4.4.1 -10 pertain to the design of structures to protect public coastal views. The subject site is not identified by the LCP as a public view point or to provide any public coastal views through the site, nor is Cliff Drive and Santa Ana 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 10 of 15 Avenue identified as a coastal view road requiring public view protection. However, as previously discussed in the Land Use Element section of this report, the applicant has significantly mitigated potential private view impacts through careful design of the proposed residences. Policies 4.4.3 -1 through 4.4.3 -18 pertain to the protection of coastal bluffs as a significant scenic and environmental resource. Specific development restrictions, including bluff top setbacks, construction techniques, and site designs standards are addressed to protect and minimize alteration to natural coastal bluffs. For the purposes of implementing the Coastal Land Use Plan, a coastal bluff is defined as, "A bluff overlooking a beach or shoreline or that is subject to marine erosion ". Additionally, a bluff is defined as, A high bank or bold headland with a broad, precipitous, sometimes rounded cliff face overlooking a plain or body of water". However, the subject site does not meet the definition of a bluff, nor a coastal bluff, as the topography of the slope does not consist of a headland, nor does it consist of a precipitous or steep cliff face, and it is not subject to marine erosion. And although the site does afford views of the harbor, the site does not immediately overlook a beach or a shoreline. Therefore the referenced policies do not apply to this subject development. Policies 4.5.1 -1 through 4.5.1 -5 pertain to. the protection of paleontological and archaeological resources. Specific requirements of the policies relate to monitoring, preservation of resources, and notification of cultural organizations. Six Native American Tribes, as identified by the Native American Heritage Commission, that may have traditional lands or cultural places located within the boundaries of the General Plan Amendment, were notified of the project and invited to consult in the planning process of this application. Only one tribe, The Gabrieleno Band of Mission Indians, responded to the notice and requested monitoring of the site and that if any artifacts are removed, that they be returned to the proper tribe. Condition Nos. 41, 42, and 43 are consistent with this request, as well as the policies of the Coastal Land Use Plan, and will insure that should any paleontological/archaeological resources be uncovered,: development activity will be suspended to avoid destruction of such resources until a determination can be made as to their significance. Zoning Code (Title 20) The subject property is located within the R -1 (Single - Family Residential) District and the proposed subdivision will remain consistent with this designation. The proposed design of the two parcels meets the minimum lot development standards as illustrated below: 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 11 of 15 Subdivision Compliance (Title 19 of the Municipal Code) In accordance with Title 19 (Subdivision Code), approval of a Parcel Map is required for the subdivision of land creating 4 or fewer parcels. The Planning Commission must make the following findings in approving the tentative parcel map: 1. That the proposed map and the design or improvements of the subdivision are consistent with the General Plan and any applicable specific plan, and with applicable provisions of the Subdivision Map Act and this Subdivision Code. As noted in the previous sections, staff believes that the proposed subdivision can be found consistent with the Single Family Detached General Plan designation of the site. Should the proposed amendment not be approved, this finding cannot be made given the proposed uses, design and improvements proposed by the applicant. The Public Works Department has reviewed the proposed tentative map and believes it is consistent with the Newport Beach Subdivision Code (Title 19) and applicable requirements of the Subdivision Map Act. The project has been conditioned to provide a number of public improvements, including the construction of full length sidewalks along both the Cliff Drive and Santa Ana Avenue frontages. However, due to topographical constraints that exist between Santa Ana Avenue and Avon Street, the development will not be required to connect Avon Street to Santa Ana Avenue. Additional conditions of approval have been included to ensure compliance with Title 19. 2. That the site is physically suitable for the type and density of development. The two parcels are proposed for residential development and are of sufficient size for the intensity and density of the proposed residential development. The proposed density of the two parcels is substantially less than the surrounding lots in the community. Vehicular access to the upper parcel will be from Cliff Drive and access to the lower parcel will be from Santa Ana Avenue, consistent with the Land Use Element prohibition of taking access from Avon Street. Condition No. 13 as been incorporated to insure access is designed to this effect and prohibited from Avon Street. The Preliminary Geotechnical Investigations that have been prepared for both of the proposed residences concluded the residential developments as feasible and safe from a geotechnical viewpoint. 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 12 of 15 3. That the design of the subdivision or the proposed improvements are not likely to cause substantial environmental damage nor substantially and avoidably injure fish or wildlife or their habitat. However, notwithstanding the foregoing, the decision - making body may nevertheless approve such a subdivision if an environmental impact report was prepared for the project and a finding was made pursuant to Section 21081 of the California Environmental Quality Act that specific economic, social, or other considerations make infeasible the mitigation measures or project alternatives identified in the environmental impact report. The site currently exists as a single - family lot with a two -story residence developed on the upper portion of the property. The lower portion of the site is isolated from other natural areas and dominated by non - native vegetation, and given its location within a developed urban setting, the likelihood that the proposed project would cause substantial environmental damage or adversely affect wildlife or their habitat is improbable. Additionally, the project qualifies for Class 3 Categorical Exemption (New Construction or Conversion of Small Structures) under the California. Environmental Quality Act as the project will result in the construction of one additional single - family residence and is located on a developed site with no environmentally significant resources present. 4. That the design of the subdivision or the type of improvements is not likely to cause serious public health problems. The development of two parcels for residential use is not expected to cause serious public health problems given the use of typical construction materials and practices. No evidence is known to exist that would indicate that the proposed subdivision will generate any serious public health problems. The parcels have been designed in compliance with all applicable subdivision standards of Title 19 and the proposed residences are conditioned to comply with R -1 development standards of the Zoning Code, insuring the protection of adequate light; air, privacy, and open space for each dwelling unit, and insuring design compatibility with the surrounding neighborhood. 5. That the design of the subdivision or the type of improvements will not conflict with easements, acquired by the public at large, for access through or use of property within the proposed subdivision. in this connection, the decision - making body may approve a map if it finds that alternate easements, for access or for use, will be provided and that these easements will be substantially equivalent to ones previously acquired by the public. This finding shall apply, only to easements of record or to easements established by judgment of a court of competent jurisdiction and no authority is hereby granted to the City Council to determine that the public at large has acquired easements for access through or use of property within a subdivision. 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 13 of 15 No public easements for access through or use of the property have been retained for the use by the public at large. 6. That, subject to the detailed provisions of Section 66474.4 of the Subdivision Map Act, if the land is subject to a contract entered into pursuant to the California Land Conservation Act of 1965 (Williamson Act), the resulting parcels following a subdivision of the land would not be too small to sustain their agricultural use or the subdivision will result in residential development incidental to the commercial agricultural use of the land. The site is not subject to a Williamson Act contract; therefore, this finding does not apply. 7. That, in the case of a "land project" as defined in Section 11000.5 of the California Business and Professions Code: (a) there is an adopted specific plan for the area to be included within the land project, and (b) the decision- making body finds that the proposed land project is consistent with the specific plan for the area. The subject property is not located within the boundaries of a specific plan; therefore, this finding does not apply. 8. That solar access and passive heating and cooling design requirements have been satisfied in accordance with Sections 66473.1 and 66475.3 of the Subdivision Map Act. Title 24 of the Uniform Building Code requires new construction to meet minimum heating and cooling efficiency standards depending on location and climate. The Newport Beach Building Department will enforce Title 24 compliance through the plan check and field inspection processes for the construction of the proposed residences. Additionally, since the lower dwelling unit will be built into the slope and benefits from southern exposure of the sun, the project will take maximum advantage of solar and passive heating. 9. That the subdivision is consistent with Section 66412.3 of the Subdivision Map Act and Section 65584 of the California Government Code regarding the City's share of the regional housing need and that it balances the housing needs of the region against the public service needs of the City's residents and available fiscal and environmental resources. The proposed subdivision facilitates the creation of one new residential unit that will be added to:the City's housing stock and furthers the City's,goal of meeting its housing needs as identified in the Regional Housing Needs Assessment. The addition of one 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 14 of 15 unit will not cause an undue strain on City resources and public services are available to serve the proposed development of the site. 10. That the discharge of waste from the proposed subdivision into the existing sewer system will not result in a violation of existing requirements prescribed by the Regional Water Quality Control Board. Waste discharge into the existing sewer system will be consistent with the existing residential use of the property and does not violate Regional Water Quality Control Board (RWQCB) requirements. Additionally, sewer connections have been conditioned to be installed per City Standards, the applicable provisions of Chapter 14.24 (Sewer Connection, Permits), and the latest revision of the Uniform Plumbing Code. 11. For subdivisions lying partly or wholly within the Coastal Zone, that the subdivision conforms with the certified Local Coastal Program and, where applicable, with public access and recreation policies of Chapter Three of the Coastal Act. The project is consistent with the City's new Local Coastal Program Land Use Plan as discussed previously in this report. The subject site to be subdivided does not abut the ocean or bay, and does not provide public access to coastal resources; therefore, no impacts to coastal access are anticipated. Charter Section 423 (Measure S) Council Policy A -18 requires that proposed General Plan amendments be reviewed to determine if a vote would be required. If a project generates more than 100 peak hour trips, 40,000 square feet of non - residential floor area or exceeds 100 dwelling units, a vote of the citizens would be required if the Council approves the suggested Amendment. The proposed amendment requests approval of only 1 additional dwelling unit, does not include any commercial floor area, and results in an increase of 0.75 AM peak hour trips and 1.01 PM peak hour trips. Therefore, none of the three thresholds to require a vote pursuant to Measure S (Greenlight) are exceeded. No other amendment has been approved .for this statistical area, and therefore no vote would be required based on a cumulative analysis. This amendment will be tracked for ten years in accordance with Section 423. Environmental Review The project qualifies for a Categorical Exemption pursuant to Section 15303 (New Construction or Conversion of Small Structures) of the Implementing Guidelines of the California Environmental Quality Act as the project will result in the construction of one additional single - family residence, below the maximum threshold permitted under this 2961 Cliff Drive (PA2005 -158) March 23, 2006 Page 15 of 15 exemption, and is located on a developed site with no environmentally significant resources present. Public Notice Notice of this hearing was published in the Daily Pilot, mailed to property owners within 300 feet of the property and posted at the site a minimum of 10 days in advance of this hearing consistent with the Municipal Code. Additionally, the item appeared upon the agenda for this meeting, which was posted at City Hall and on the city website. Summary Staff believes that findings necessary for project approval can be made. It is staffs opinion that the two parcel subdivision would not prove detrimental to the area and is compatible with the surrounding area of Newport Heights. Should the Planning Commission conclude that the project as proposed would not be compatible with the surrounding uses and that the project would not be appropriate for the site; the project should be denied or modified to address issues of design if a redesigned project is advisable. Prepared by: Ime Murillo, Associate Planner Submitted by: 45�41A�-K atrick Aif&cT, Actifig Planning Director Exhibits 1. Draft Resolution No. 2005 findings and conditions of approval 2. Slope Analysis 3. Tentative Parcel Map 4. Architectural Plans S. Preliminary Geotechnical Investigation Reports 6. Hydrology /Hydraulic Study 7. Topographic Survey EXHIBIT 1 Draft Resolution No. 2005 6 RESOLUTION NO. A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF NEWPORT BEACH RECOMMENDING THAT THE CITY COUNCIL APPROVE GENERAL PLAN AMENDMENT NO. 2005 -003, AND, TENTATIVE PARCEL MAP NO. 2005 -035 FOR PROPERTY LOCATED AT 2961 CLIFF DRIVE (PA 2005 -158). WHEREAS, an application was filed by Thirtieth Street Architects, Inc., with respect to property located at 2961 Cliff Drive, and legally described as Lot Park '2" of the First Addition to Newport Heights in the City of Newport Beach, State of California, as per map filed in Book 4, page 94, of miscellaneous maps, in the office of the County Recorder to subdivide an existing single - family lot into two separate single- family parcels. The application requests an amendment to the Land Use Element of the General Plan to allow the subdivision of a property located within Statistical Area H -2, where subdivisions are currently prohibited; and WHEREAS, a public hearing was held by the Newport Beach Planning Commission on March 23, 2006 in the City Hall Council Chambers, 3300 Newport Boulevard, Newport Beach, California. A notice of time, place, and purpose of the meeting was given in accordance with the Municipal Code and State Law. Evidence, both written and oral, was presented to and considered by the Planning Commission at this meeting; and WHEREAS, the property is located in the Sub -Area 1 of Statistical Area H2 (Newport Heights) of the Land Use Element of the General Plan and has a land use designation of Single Family Detached (SFD) and the property is zoned Single Family Residential (R1); and WHEREAS, a General Plan Amendment is required to allow the subdivision of the subject single- family lot into two single - family parcels because Sub -Area 1 of Statistical Area H2 currently prohibits subdivisions that would result in additional dwelling units being permitted; and WHEREAS, the proposed subdivision is consistent with the existing Single Family Detached General Plan designation and will remain compatible with the surrounding neighborhood as the density of the project is 2.6 d.u. /acre, which is substantially less than the surrounding lots in the community and will not cause the area to increase in average density; and WHEREAS, the existing topography of the lot naturally divides the property into two building pad levels and is conducive to the construction of two structures that will remain compatible with the existing residential developments adjacent to the site; and WHEREAS, the property is consistent with Policy D of the Land Use Element of the General Plan which states, "The siting of new buildings and structures shall be controlled and regulated to ensure, to the extent practical, the preservation of public City of Newport Beach Planning Commission Resolution No. _ Page 2 of 15 views, the preservation of unique natural resources, and to minimize the alteration of natural landforms along bluffs and cliffs, "for the following reasons: Unique natural resources do not exist on the site and the sloping property is not a natural landform requiring protection as identified in the Implementation Measures of Policy D because: a. A slope analysis has been performed on the site and concludes that the site does not meet the definition of a coastal bluff as defined per this policy because only 9% of the property consists of a slope 2:1 or greater. b. The site does not meet the Coastal Land Use Plan definition of a bluff or coastal bluff because the topography of the slope does not consist of a headland, nor does it consist of a precipitous or steep cliff face, and, it is not subject to marine erosion. c. The existing lot can be completely developed with one large single- family home with no restrictions beyond the minimum development standards. 2. The proposed development does not impact any public views and minimizes potential private view impacts to the greatest extent possible because: a. The site is not identified in City's Coastal Land Use Program as a public view point or to provide public coastal views through the site, nor is Cliff Drive and Santa Ana Avenue identified as a coastal view road requiring public view protection. b. Private views from adjacent residences may be affected, and Santa Ana Avenue does currently afford a coastal view, however the City does not have any private view protection ordinances or policies. c. The lower residence has been designed into the hillside using the natural topography of the ' -parcel, maintaining a majority of the building mass below the Santa Ana Avenue curb line and preserving views off Santa Ana Avenue. d. The applicant substantially modified the design of the upper house by reducing the overall height and mass of the proposed residence by reducing the second floor and shifting the second floor back closer to Cliff Drive, preserving the existing views to the maximum extent possible. 3. The project is consistent with Implementation Measure D -3 which states that no structures shall be permitted in areas of geologic hazard where natural geologic processes can pose a threat to the public health, safety, and welfare, because: t� City of Newport Beach Planning Commission Resolution No. _ Page 3 of 15 a. Preliminary Geotechnical Investigations have been prepared for both of the proposed residences and concluded that the proposed residential developments are feasible and safe from a geotechnical viewpoint and that the project will not adversely impact adjoining properties, provided the recommendations of the report are implemented in design, construction, and maintenance. b. No active faults were observed or previously mapped through the site, and fault rupture across the property is not anticipated. c. No slumps or landslips that may impact the site were noted in the study area or on any reviewed referenced publications. d. And the lack of groundwater in the upper 50 feet of the subject site results in the potential for liquefaction to be considered remote. WHEREAS, the Coastal Land Use Plan sets forth goals, objectives, and policies that govern the use of land and water in the coastal zone and addresses land use and development, public access and recreation, and coastal resources protection. The proposed subdivision is consistent with the LCP for the following reasons: The project site is designated for Very Low Density Residential (RVL 2.6 - 4.5 DU /AC) by the LCP. 2. The subject property is located within an existing developed area of the Coastal Zone and its current density is well below the maximum density limit established for the RVL designation of the LCP. Subdividing the site into two parcels will not cause the site to exceed the density limit established under the RVL designation. 3. Public services and infrastructure are available to serve the proposed development, and all applicable improvements required by Section 19.28 (Subdivision Improvements) of the Subdivision Code are to be satisfied by the applicant. 4. The residential structures proposed to be constructed within the subject parcels are proposed and conditioned to comply with all applicable R -1 development regulations of the City's Zoning Code, specifically pertaining to setbacks, floor area, and height limitations, to insure design compatibility with the surrounding neighborhood. 5. Preliminary Geotechnical Investigations have been prepared for both of the proposed residences and concluded that the proposed residential developments are feasible and safe from a geotechnical viewpoint. Additionally, the study noted that geologic hazards were not observed or anticipated on the site. p City of Newport Beach Planning Commission Resolution No. Page 4 of 15 6. The subject site is not identified by the LCP as a public view point or to provide any public coastal views through the site, nor is Cliff Drive and Santa Ana Avenue identified as a coastal view road requiring public view protection. However, the applicant has significantly mitigated potential private view impacts through careful design of the proposed residences. 7. The project has been conditioned to insure that should any paleontological /archaeological resources be uncovered, development activity will be suspended to avoid destruction of resources until a determination can be made as to the significance of the resources. 8. No impacts to coastal access are anticipated given the project location, as the site does not abut the ocean or bay and does not currently provide public access to coastal resources. WHEREAS, Charter Section 423 requires that proposed General Plan amendments be reviewed to determine if a vote would be required. If a project generates more than 100 peak hour trips, 40,000 square feet of non - residential floor area or exceeds 100 dwelling units, a vote of the citizens would be required if the Council approves the suggested Amendment. The proposed amendment requests approval of only 1 additional dwelling unit, does not include any commercial floor area, and results in an increase of 0.75 AM peak hour trips and 1.01 PM peak hour trips. Therefore, none of the three thresholds to require a vote pursuant to Measure S (Greenlight) are exceeded. Additionally, no other amendment has been approved for this statistical area, and therefore no vote would be required based on a cumulative analysis. This amendment will be tracked for ten years in accordance with Section 423; and WHEREAS, the project is located within Newport Heights where public services and infrastructure are available to serve the additional dwelling unit to be created by this proposed subdivsion. Additionally, all applicable improvements required by Section 19.28 (Subdivision Improvements) of the Subdivision Code are to be satisfied by the applicant; and WHEREAS, Pursuant to Section 19.12.070 of the City Subdivision Code, the following standard findings must be made to approve the Tentative Parcel Map: 1. The proposed map and the design or improvements of the subdivision are consistent with General Plan and any applicable specific plan, and with the applicable provisions of the Subdivision Map Act and Title 19 because: a. The proposed parcels are consistent with Single Family Detached General Plan designation of the site. p City of Newport Beach Planning Commission Resolution No. _ Page 5 of 15 b. The Public Works Department has reviewed the proposed Tentative Parcel Map and found it consistent is consistent with the Title 19 and applicable requirements of the Subdivision Map Act, an no exceptions have been requested from the design standards. c. Due to topographical constraints that exist between Santa Ana Avenue and Avon Street, the development will not be required to connect Avon Street to Santa Ana Avenue. d. Conditions of approval have been included to ensure compliance with Title 19 and the Subdivision Map Act. 2. The site is physically suitable for the type and density of development because: a. The two parcels are proposed for residential development and are of sufficient size for the intensity and density of the proposed residential development. b. The proposed density of the two parcels is substantially less than the surrounding lots in the community. c. Vehicular access to the upper parcel will be from Cliff Drive and access to the lower parcel will be from Santa Ana Avenue, consistent with the Land Use Element prohibition of taking access from Avon Street. d. The site is physically suitable for the development and geologic hazards were not observed or anticipated on the site by the Preliminary Geotechnical Investigations that have been prepared for both of the proposed residences, which also concluded the residential developments as feasible and safe from a geotechnical viewpoint. 1 The design of the subdivision or the proposed improvements are not likely to cause substantial environmental damage nor substantially and avoidably injure fish or wildlife or their habitat because: a. The site currently exists as a single - family lot with a two -story residence developed on the upper portion of the property and the property can currently be completely built on with no development restrictions beyond the minimum R-1 development standards of the Zoning Code. b. The proposed subdivision will not change the possible level of development that can occur on the site, but only increases the density by permitting one additional unit. P'} City of Newport Beach Planning Commission Resolution No. _ Page 6 of 15 c. The site is dominated by non - native vegetation, and given its location within a developed urban setting, the likelihood that the proposed project would cause substantial environmental damage or adversely affect wildlife or their habitat is improbable. 4. The design of the subdivision or the type of improvements is not likely to cause serious public health problems because: a. The development of the two parcels is for residential use and is not expected to cause serious public health problems given the use of typical construction materials and practices. b. No evidence is known to exist that would indicate that the proposed subdivision will generate any serious public health problems. c. The parcels have been designed in compliance with all applicable subdivision standards of Title 19 and the proposed residences are conditioned to comply with R -1 development standards of the Zoning Code, insuring the protection of adequate light, air, privacy, and open space for each dwelling unit, and insuring design compatibility with the surrounding neighborhood. 5. The design of the subdivision or type of improvements will not conflict with easements, acquired by the public at large, for access through, or use of, property within the proposed subdivision because no public easements for access through, or use of, the property have been retained for the use by the public at large. 6. Solar access and passive heating and cooling design requirements have been satisfied in accordance with Sections 66473.1 and 66475.3 of the Subdivision Map Act because: a. Title 24 of the Uniform Building Code requires new construction to meet minimum heating and cooling efficiency standards depending on location and climate. b. The Newport Beach Building Department enforces Title 24 compliance through the plan check and field inspection processes. c. Since the lower dwelling unit will be built into the slope and benefits from southern exposure of the sun, the project will take maximum advantage of solar and passive heating. 9�°J City of Newport Beach Planning Commission Resolution No. Page 7 of 15 7. The subdivision is consistent with Section 66412.3 of the Subdivision Map Act and Section 65584 of the California Government Code regarding the City's share of the regional housing need and that it balances the housing needs of the region against the public service needs of the City's residents and available fiscal and environmental resources because: a. The proposed subdivision facilitates the creation of one new residential unit that will be added to the City's housing stock and. further the City's goal of meeting its housing needs as identified in the Regional Housing Needs Assessment. b. The addition of one unit will not cause an undue burden on City resources and public services are available to serve the proposed development of the site 8. The discharge of waste from the proposed subdivision into the existing sewer system will not result in a violation of existing requirements prescribed by the Regional Water Quality Control Board because: a. Waste discharge into the existing sewer system will be consistent with the existing residential use of the property and does not violate Regional Water Quality Control Board (RWQCB) requirements. b. Sewer connections have been conditioned to be installed per City Standards, the applicable provisions of Chapter 14.24 (Sewer Connection, Permits), and the latest revision of the Uniform Plumbing Code. 9. The subdivision conforms to the certified Coastal Land Use Plan and, where applicable, with public access .and recreation policies of Chapter Three of the Coastal Act because: a. • The project has been designed and conditioned for consistency with the City's new Local Coastal Program Land Use Plan. b. The subject site to be subdivided does not abut the ocean or bay, and does not provide public access to coastal resources; therefore, no impacts to coastal access are anticipated. WHEREAS, the project qualifies for a Categorical Exemption pursuant to Section 15303 (New Construction or Conversion of Small Structures) of the Implementing Guidelines of the California Environmental Quality Act as the project will result in the construction of one additional single - family residence, below the maximum threshold permitted under this exemption, and is located on a developed site with no environmentally significant resources present, and �1 City of Newport Beach Planning Commission Resolution No. _ Page 8 of 15 WHEREAS, the Planning Commission finds that judicial challenges to the City's CEQA determinations and approvals of land use projects are costly and time consuming. In addition, project opponents often seek an award of attorneys' fees in such challenges. As project applicants are the primary beneficiaries of such approvals, it is appropriate that such applicants should bear the expense of defending against any such judicial challenge, and bear the responsibility for any costs, attorneys' fees, and damages which may be awarded to a successful challenger; and NOW, THEREFORE, BE IT RESOLVED: Section 1. The Planning Commission hereby recommends that the City Council of the City of Newport Beach adopt General Plan Amendment No. 2005 -003 to allow the subdivision of 2961 Cliff Drive into two separate single - family parcels and revise language contained within the Land Use Element pertaining to the change in subdivision, as shown in Exhibit "A ". Section 2. The Planning Commission hereby further recommends that the City Council of the City of Newport Beach adopt Tentative Parcel Map No. 2005 -035, subject to Conditions of Approval in Exhibit "B" attached hereto and made part hereof. PASSED, APPROVED AND ADOPTED THIS 23`d DAY OF MARCH 2006. M mm Michael Toerge, Chairman Barry Eaton, Secretary AYES: NOES: ABSENT: -5 City of Newport Beach Planning Commission Resolution No. _ Page 9 of 15 Exhibit "A" THE FOLLOWING CHANGES WILL BE MADE TO THE LAND USE ELEMENT AND OTHER PROVISIONS OF THE LAND USE ELEMENT SHALL REMAIN UNCHANGED: Newport Heights Area (Statistical Area H2) 1. Newport Heights. This area is located northerly of the Manner's Mile Specific Plan area between Santa Ana Avenue and Irvine Avenue. The area is designated predominantly for Single Family Detached development, with the area near 16th Street and Tustin Avenue shown for Two - Family Residential and Multi - Family Residential land use. No subdivision which will result in additional dwelling units is permitted, except for the site at 2919 Cli Drive, ...tde ..o,,.. ; «e.. ,. ,,..; «:..,,,..., ..c 7r 000 sq a ,. fb Hdable let r r each new «....,,et 2961 Cliff Drive, which may be subdivided to create one additional parcel with a minimum lot area of 14,500 square feet. A minimum of 2,000 sq. ft. of buildable lot area is required for duplex development in the Two Family area, and one unit is allowed for each 2,178 sq. ft. of buildable lot area in the Multi - Family Residential area. The area is allocated a maximum of 790 791 dwelling units. Residential access from Avon Street is prohibited, except for lots where no access is available from either Cliff Drive or Santa Ana Avenue. A 1 ESTIMATED GROWTH FOR STATISTICAL AREA H2 Residential (in du's) Commercial (in sq. ft.) Existing Gen. Plan Projected Existing Gen. Plan Projected 1/1/87 Projection Growth 1/1/87 Projection Growth 1. Newport Heights 773 784791 89 -0- -0- -0- 2. Cliff Drive Park -0- -0- -0- 900 1,000 100 3. Ensign View Park -0- -0- -0- 3,000 5,000 2,000 4. Newport Hgts. Elem. -0- -0- -0- 35,248 39,683 3,435' TOTAL 773 781791 89 39,148 45,683 5,535 Population 1,531 1,546 16 A 1 City of Newport Beach Planning Commission Resolution No. Page 10 of 15 Exhibit "B" CONDITIONS OF APPROVAL Tentative Parcel Map No. 2005 -035 (PA 2005 -158) 1. The proposed residential development shall comply with the R -1 development standards of the Zoning Code and shall remain in substantial conformance with the architectural plans stamped with the date of this meeting, except as noted in the following conditions. 2. The Map shall be in substantial conformance with the Tentative Parcel Map dated February 15, 2006, except as noted in the following conditions. 3. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions. of approval. 4. The Tentative Parcel Map shall expire within 24 months from the date of approval unless extensions are granted prior to expiration in accordance with the Subdivision Ordinance and Subdivision Map Act. 5. The applicant shall obtain a Coastal Development Permit from the California Coastal Commission prior to the recordation of the parcel map and prior to the issuance of any building or grading permit for the project. 6. Height of proposed future residences shall be measured from natural grade as depicted on the topographic survey prepared by Myers & Associates on August 31, 2005 for the subject site. 7. The applicant is required to obtain all applicable permits from the City Building and Fire Departments. The construction plans must comply with the most recent, City- adopted. version of the California Building Code. 8. All buildings shall be provided with fire sprinklers, as required by the Fire Department. 9. Prior to the recordation of the parcel map, the applicant shall provide an additional fire hydrant in a location approved by the Fire Department. 10. Prior to the recordation of the parcel map, park dedication fees for one dwelling unit shall be paid in accordance with Chapter 19.52 of the Newport Beach Municipal Code. a1 City of Newport Beach Planning Commission Resolution No. _ Page 11 of 15 11. Both project driveways and improvements at the comer of Cliff Drive and Santa Ana Avenue shall be reviewed and approved by the City Traffic Engineer to insure adequate sight distance is provided per City Standard STD - 110 -L. Slopes, landscaping, walls and other obstructions shall be considered in line of site requirements. Landscaping within the line of sight shall not exceed a height of twenty-four inches. The sight distance requirement may be modified at non - critical locations, subject to the approval of the Traffic Engineer. 12. Residences shall be designed in such a manner that allow vehicles exiting garage spaces adequate space to turn around on site; backing out onto adjacent public streets shall be prohibited. 13. Vehicular access shall be taken from either Cliff Drive or Santa Ana Avenue, and access shall be prohibited from Avon Street. 14. All work conducted within the public right -of -way shall be approved under an encroachment permit and all non - standard improvements within the public right - of -way requires an encroachment agreement issued by the Public Works Department. 15. Plantings within the public right -of -way along Santa Ana Avenue and Cliff Drive shall be turf or other low planting that can accommodate pedestrian traffic. 16. The Map shall be prepared on the Califomia Coordinate System (NA083). Prior to recordation of the Maps, the surveyorlengineer preparing the Maps shall submit to the County Surveyor and the City of Newport Beach a digital - graphic file of said Maps in a manner described in the Orange County Subdivision Code and Orange County Subdivision Manual. The Maps to be submitted to the City of Newport Beach shall comply with the City's CADD Standards. Scanned images will not be accepted. 17. Prior to recordation of the Maps, the surveyof /engineer preparing the Maps shall tie the boundary of the Maps into the Horizontal Control System established by the County Surveyor in a manner described in Section s 7 -9 -330 and 7 -9 -337 of the Orange County Subdivision Code and Orange County Subdivision Manual, Subarticle 18. Monuments (one inch iron pipe with tag) shall be set On Each Lot Comer unless otherwise approved by the Subdivision Engineer. Monuments shall be protected in place if installed prior to completion of construction project. 18. All improvements shall be constructed as required by Ordinance and the Public Works Department, 19. Upon submittal of building plans for plan check, a hydrology and hydraulic study shall be submitted by the applicant, and approved by the City, to ascertain the RY City of Newport Beach Planning Commission Resolution No. Page 12 of 15 existing storm drain system along Avon Street has sufficient excess capacity to accept all of the on -site storm runoff proposed for discharge into said system. 20. The design of all public facilities required to serve the development shall comply with the City's Design Criteria, Standard Plans, and drawing submittal requirements. All of the plan sheets shall be wet sealed, dated, and signed by the California registered professionals responsible for the designs shown on said plans. 21. A minimum 10 -foot radius cut -off easement for street and utilities purposes at the Santa Ana Avenue/ Cliff Drive property comer shall be recorded as part of the Map. 22. All private easements shall be recorded as part of the Map. 23. Full width sidewalks shall be constructed along the length of the Santa Ana Avenue and Cliff Drive frontages. 24. An ADA compliant curb access ramp shall be constructed at the Santa Ana Avenue /Cliff Drive return. 25. All proposed driveway flares (top of "X "s) shall maintain a minimum clear distance of 5 -feet from the nearest power pole, pipe vents, above ground facilities, or other public facilities. 26. All storm drain and sanitary sewer mains shall be installed with MacWrap 27. In accordance with the provisions of Chapter 13 of the Newport Beach Municipal Code or other applicable section or chapter, a new street tree shall be planted along the Cliff Drive frontage and existing street trees shall be protected in place during the construction of subject project, unless otherwise approved by the General Service Department and the Public Works Department through an encroachment permit or agreement, if required. 28. Construction surety in a form acceptable to the City, guaranteeing the completion of various required public improvements, shall be submitted to the Public Works Department prior to encroachment permit issuance. 29. The developer shall be responsible for repairing and /or reconstruction of damage done to the Santa Ana Avenue or Cliff Drive roadway pavement surrounding the development site by private work. 30. Provisions shall be made to prevent proposed garages from being flooded by storm runoff traveling on the inclined driveways. Al City of Newport Beach Planning Commission Resolution No. _ Page 13 of 15 31. Each unit shall be served by individual water service and sewer lateral connection to the public water and sewer systems. 32. All overhead utilities serving the development shall be undergrounded. 33. Vehicular traffic on Santa Ana Avenue shall be maintained throughout duration of construction. 34. County Sanitation District fees shall be paid prior to issuance of any building permits. 35. The applicant shall be responsible for the payment of all administrative costs identified by the Planning Department within 30 days of receiving a final notification of costs or prior to the release for recordation of the parcel map. 36. Prior to the issuance of any building permits, Public Works Department plan check and inspection fee shall be paid. 37. Prior to issuance of grading or building permits, the project applicant shall have an approved final Project Water Quality Management Plan (WQMP). The City of Newport Beach requires all new development and significant redevelopment projects to prepare and submit a WQMP to the City for review and approval. 38. Prior to the issuance of any grading permits, a Stormwater Pollution Prevention Plan ( SWPPP) shall be prepared and approved by the City of Newport Beach as the local permitting agency in accordance with the requirements of the Regional Water Quality Control Board (RWQCB). The SWPPP shall include BMPs to eliminate and /or minimize stormwater pollution prior to, and during construction. The SWPPP shall require construction to occur in stages and stabilized prior to disturbing other areas and require the use of temporary diversion dikes and basins to trap sediment from run -off and allow clarification prior to discharge. 39. Prior to issuance of any grading permits, the project applicant shall document to the City of Newport Beach Building Department that all facilities will be designed and constructed to comply with current seismic safety standards and the current City- adopted version of the Uniform Building Code. 40. Prior to issuance of any grading permits, an updated geotechnical report shall be submitted with construction drawings for plan check. The Building Department shall ensure that the project complies with the geotechnical recommendations included in the report, as well as additional requirements, if any, imposed by the Newport Beach Building Department. 56 City of Newport Beach Planning Commission Resolution No. _ Page 14 of 15 41. Prior to the issuance of any grading permits, the applicant shall provide written evidence to the Planning Director that a qualified archaeologist has been retained to observe grading activities and conduct salvage excavation of archaeological resources as necessary. The archaeologist shall be present at the pre- grading conference, shall establish procedures for archaeological resources surveillance, and shall establish, in cooperation with the applicant, procedures for temporarily halting or redirecting work to permit the sampling, identification and evaluation of the artifacts as appropriate. If additional or unexpected archaeological features are discovered, the archaeologist shall report such findings to the applicant and to the Planning Department. If the archaeological resources are found to be significant, the archaeological observer shall determine appropriate actions, in cooperation with the applicant, for exploration and /or salvage. These actions, as well as final mitigation and disposition of the resources, shall be subject to the approval of the Planning Director. 42. Prior to the issuance of the any grading permits, the applicant shall provide written evidence to the planning director that a qualified paleontologist has been retained to observe grading activities and conduct salvage fossils as necessary. The paleontologist shall be present at the pre - grading conference, shall establish procedures for paleontological resource surveillance, and shall establish cooperation with the applicant, procedures for temporarily halting or redirecting work to permit the sampling, identification and evaluation of fossils. If major paleontological resources are discovered which require long term baiting or redirecting of grading, the paleontologist. shall report such findings to the applicant and to the Planning Department. The paleontologist shall determine appropriate actions, in cooperation with the applicant, which ensure proper exploration and /or salvage. These actions, as well as final mitigation and disposition of the resources, shall be subject to the approval of the Planning Director. 43. During construction of any proposed improvements, in accordance with Public Resources Code 5097.94, if human remains are found, the Orange County coroner must be notified within 24 hours of the discovery. if the coroner determines that the remains are not recent, the coroner will notify the Native American Heritage Commissions in Sacramento to determine the most likely descendent for the area. The designated Native American representative then determines, in consultation with the property owner, the disposition of the human remains. 44. To the fullest extent permitted by law, the applicant shall indemnify, defend and hold harmless City, its City Council, its. boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits; losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney's 5` City of Newport Beach Planning Commission Resolution No. Page 15 of 15 fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City's approval of the General Plan Amendment No. 2005 -003 and Parcel Map No. 2005 -035; and /or the City's related California Environmental Quality Act determinations. �a EXHIBIT 2 Slope Analysis 35 1� !�) Q> N Lu O 2 N o LU00 J U m ti 4 Z O U w 'L a$� g�a�s It I a All NO to qN m ��ekma a `3q EXHIBIT 4 Architectural Plans Ak 'F. 5p yy LKI II z N o� VI U z R 6 N A a 8 Wig $ p 7 1 § %4 :=5 9 sea T� z a �Oa aw z w qNz hti a ak k 9 i t at z w x 0 0 F O� C-1 W U z w W a 2 W H ra U hl jj � 10 Y $ r'aa�2�a 9 9 lul" llfilYd a a a 0. 0. O 0 ON 0 W CJ z w m F A� a Ale i i6 w Y z F Q W d E 0 Q d 0 z V I O Q W d F Q W V) z O rz O aw r{T� Vyy Lti �qQ m Q� F� vil v �I �I I `I II i� I� �I I ,I I' } z ..o ow I o W `V. W W i U Ilia `; a .91! AM=", py sQ 0 U z w C4 6 Fn qNz : J 11 $- A� a w x O O 0 W V z w a N A a V e 50 R a a g �a w F .e ON 0 t/] W Q� � x �Qw m rn3 N ZWZW H r� V t I a 4 wo a � �P t 0 F OrA U W ro a A U �I 1 6t 4: z o� W. U' a N nl j ogh ✓� �m zlm m smgNaica —:nc Wriq . i9sz Ell If lilt soil V7 0 ilk d S$�4iLi1� ➢ ➢�SiiiA 3.c__ z 3 u all !fib �Milln��� 11ijo 01 O �u e O`v N� �c WQ �Um Qa �z I o �v W c$ a l l z g EXHIBIT 5 Preliminary Geotechnical Investigation Reports N DAVID A. PURKIS, PE Consulting Civil Engineer May 6, 2005 Project No. 05 -1647 TO: Elan Enterprises Inc. 1380 Moorea Laguna Beach, CA 92651 Attention: Kaveh Labijani SUBJECT: Preliminary Geotechnical Investigation for Foundation Design Residential Development of Lot 1 of 2961 Cliff Drive, Newport Beach, California INTRODUCTION The results and recommendations, of our preliminary geotechnical investigation, pertinent to proposed residential development of the subject property, are provided herein. The investigation has addressed the distribution and engineering properties of earth materials in order to develop appropriate conclusions regarding the proposed development and to provide recommendations for design and construction. A topographic survey (Reference 1) depicting the proposed development was used as a base map (Plate 1) to plot the locations of exploratory excavations and geologic data for the subject site. Conclusions and recommendations herein are pertinent to construction of a new single - family residence as depicted on Plate 1. Grading and foundation plans are not available at this time and will utilize portions of this report for their preparation. This office should review these plans to determine the applicability of the contents of this report. This investigation was conducted in conjunction with the adjacent lot (Lot 2 of 2%1 Cliff Drive). SCOPE OF WORK The investigation included: 1. Geotechnical reconnaissance of the subject site. 2. One exploratory boring drilled with a truck mounted bucket auger. 3. Four exploratory trenches excavated by hand. 4. Core and bulk sampling of representative earth materials from the excavations. 5. Laboratory testing of representative samples. 6. Engineering and geotechnical analysis. 7. Preparation of this report and the accompanying illustrations. 2377 S. EL CAMINO REAL #203, SAN CLEMENTE, CA 92672 • 949.369.9701 • fax 949.661.1562 10 Elan. Lot 1 May 6, 2005 Page 2 ACCOMPANYING ILLUSTRATIONS AND APPENDICES Figure 1 - Site Location Map Figure 2 - Geologic Map (Morton & Miller, 1981) Figure 3 - Geologic Map (Fife, 1973) Figure 4 - Regional Fault Map Figure 5 - Active Fault Near - Source Zones Map Figure 6 - Seismic Hazard Zones Map Figure 7 - USGS Ground Acceleration Lookup Results Figure 8 - Typical Retaining Wall Subdrain Detail Appendix A - Logs of Exploratory Borings Appendix B - Exploration, Field and Laboratory Testing Appendix C - List of References Appendix D - Standard Grading Specifications Appendix E - Guidelines for General Site Maintenance Plate I - Geotechnical Plot Plan Plate 2 - Geotechnical Cross Sections SITE DESCRIPTION The subject site is an irregular shaped lot with an approximate area of 10,000 square feet and is approximately half of a proposed lot split of the existing property. The site has a relatively level pad area fronting Cliff Drive to the northeast and a descending slope to the southwest. The current pad is at an approximate elevation of 70t feet above sea level. The property is adjacent to Santa Ana Street to the northwest and residential property to the southeast. The subject property is presently developed with a two-story residential structure as depicted on Plate 1. The site is located at approximately N33.6r latitude by W 117.93° longitude. PROPOSED DEVELOPMENT Based on Reference 1, the proposed development will consist of a multiple -level residence with associated hardscape and landscape elements. The residence will have a lower level requiring retaining walls that will daylight on the rear slope area. fiat Elan. Lot 1 May 6, 2005 Page 3 SURFACE DRAINAGE The surface runoff associated with the site is essentially that which falls directly on the lot as precipitation. Surface water collected on the site should be directed to the street or a suitable storm drainage collection. FIELD EXPLORATION One exploratory boring and four exploratory trenches were excavated at the subject site to the approximate depths and at the approximate locations shown in Appendix A and on Plate 1. Core and bulk samples obtained for laboratory testing and analysis. The excavations were logged following excavation. The logs of the borings are included in Appendix A. A more detailed description of the field sampling process is contained in appendix B. LABORATORY TESTING Laboratory testing consisted of moisture /density, maximum density/optimum moisture, grain size, direct shear, expansion index and sulfate ion determinations. Testing procedures and test results are contained in Appendix B. Certain of the results are also contained on the trench logs in Appendix A. GEOTECHNICAL CONDITIONS GEOLOGIC SETTING The City of Newport Beach is situated on the southwesterly slope of the San Joaquin Hills that descends south to southwesterly to the Pacific Ocean with a coastal zone comprised of wave -cut terraces that slope gently. The subject site is situated on the coastal terrace at roughly 70 feet above sea level. The terraces in the region of the subject site were cut in sedimentary bedrock, which has been assigned to the Monterey or Capistrano Formation of Miocene age (Reference 4). Wave - transported sediments (principally medium to fine sands) were deposited. on the terraces as they were cut. ko�- Elan. Lot 1 May 6, 2005 Page 4 EARTH MATERIALS Based on a review of the literature, geologic maps, field observations and subsurface exploration (Appendix A), the following geologic units were observed or noted: Artificial Fill (Ai) I Residual Soils (Ors) Surficial earth materials consisting of artificial fill and undifferentiated residual soils that extend approximately 15 feet below the existing pad on the property. These soils are reddish brown, silty sands that are moist and medium dense to dense. The upper portions of these soils are not suitable for foundation support without reprocessing and recompacting. Marine Terrace Deposit (Otml Lying beneath the surface soils are Marine Terrace Deposits consisting of gray brown fine to coarse sands and silty sands. These materials are moist and dense to very dense. Bedrock Based on regional mapping, the bedrock underlying the site at depth is assigned to the Monterey Formation or the Capistrano Formation, which are sedimentary rock of marine origin and of Miocene age— The bedrock was not encountered in the exploratory excavations. Competent terrace deposits, certified fill and/or approved soils are suitable for support of proposed building loads. SURFICAL RUNOFF No evidence of former uncontrolled runoff onto or from the site has been observed. The proposed development on the relatively flat lot is not anticipated to adversely impact surrounding properties, provided proper civil engineering design for the control of drainage is implemented. GROUND WATER Groundwater was not encountered in any of the exploratory excavations made during this investigation and is not anticipated to be a constraint to construction. 51 Elan. Lot 1 May 6, 2005 Page 5 LIQUEFACTION AND LANDSLIDES The subject site is not located in a seismic hazard zone as depicted on Reference 5 by the California Department of Conservation (refer to Figure 6). This reference depicts zones of required investigation for Liquefaction or Earthquake - Induced Landslides in the Newport Beach Quadrangle. Reference 8 defines these areas as: "Areas where historical occurrence of liquefaction / landslide movement, or local geological, geotechnical and groundwater / subsurface water conditions indicate a potential for permanent ground displacements such that mitigation as defined in Public Resources Code section 2983 (c) would be required ". However, the base of the slope near Pacific Coast Highway is depicted as a zone of potential liquefaction. Site - specific exploration indicates that there is a lack of groundwater in the upper 50 feet of the subject site, therefore, the potential for liquefaction is considered remote. No slumps or landslides that may impact the site were noted in the study area during our investigation or on any of the reviewed referenced publications. The non - cohesive soils that comprise the lower slopes may experience localized surficial instability. Surficial slope conditions are not anticipated to be problematic to the proposed development provided adequate setback of foundation elements as recommended herein are utilized in design and construction. SEISMIC CONSIDERATIONS There are no active faults observed or previously mapped that pass through the site. The nearest active fault is the Newport Inglewood Fault (NIF) [refer to Figure 41. The Newport- Inglewood Fault Zone could produce an earthquake of magnitude 6.9 (Reference 11) with local strong ground motion equivalent to at least VIII on the modified Mercalli Scale. The Southern California area is susceptible to strong shaking from earthquakes originating from the NIF, the Elsinore Whittier Fault, the San Jacinto Fault and the San Andreas Fault (Figures 4 & 5). A large earthquake, magnitude 6.3 occurred off Newport Beach on March 11, 1933, and more recently a 4.6 to 4.9 magnitude earthquake occurred just offshore from Newport Beach on April 7, 1989. Both of these earthquake epicenters were on the NIF. In Laguna Beach a 4.5 magnitude earthquake occurred on October 27, 1969. The epicenter was located 1000 feet offshore of Crescent Bay. From 1934 to 1937, earthquakes with U� Elan. Lot l May 6, 2005 Page 6 epicenters west of Emerald Bay and magnitudes ranging from 1.5 to 2.0 were reported. In 1812, an earthquake of sufficient magnitude to destroy the mission occurred in San Juan Capistrano. The Probalistic Seismic Hazard Mapping Ground Motion website of the California Geologic Survey returns a Peak Ground Acceleration value of 0.43g (alluvium site) for 10 percent probable exceedance in a 50 year period for the site's global coordinates (refer to Figure 7). The Active Fault Near - Source Zone Map, N -34 (Figure 5) indicates the site is located approximately 1.5 Kilometers from the Newport Inglewood fault. The Newport Inglewood fault is identified as a "Type B" fault, capable of a Moment Magnitude 6.9 earthquake. In summary, this property is not subject to any special seismic hazards as compared to other nearby residences in similar geologic environments. Ground rupture or liquefaction as a result of seismic shaking is remote. There is no evidence of active faulting or ground rupture on the site. Seismic design in accordance with the latest edition of the California Building Code using the parameters provided in the recommendation section of this report is considered appropriate. C��l�•�C�7�T.� 1. A proposed residential development can be feasible and safe from a geotechnical viewpoint provided it is done in accordance with the conclusions and recommendations provided herein and that this office is retained during the design and construction phases to assure conformance with these requirements. 2. A multiple story wood framed single- family residence is proposed for the subject lot. 3. Earth materials underlying the proposed development area, as revealed in the exploratory excavations and as depicted in literature consist of surficial soils and Terrace Deposits atop bedrock of the Monterey or Capistrano Formations. (95 Elan. Lot 1 May 6, 2005 Page 7 4. Groundwater was not encountered at the site and is not anticipated to be a development or construction constraint. 5. Unapproved soils in areas supporting structural elements should be removed and recompacted to a minimum depth of two feet below the bottoms of proposed footings., 6. Competent approved native or certified fill soils will be suitable for support of foundation elements. All slabs and footings should be designed in accordance with the recommendations of this report to mitigate against substrata imperfections and seismic shaking. 7. Results of laboratory tests indicate very low expansion potential for near surface soils in accordance with Table 18 -I -B of the 2001 California Building Code (CBC). 8. Results of laboratory tests indicate a negligible sulfate exposure classification in accordance with Table 19 -A-4 of the CBC. 9. Earth materials at the subject site should excavate readily with conventional construction equipment. 10. Fault rupture across the property is not anticipated: Liquefaction is considered remote. 11. Seismic design in accordance with the latest edition of the California Building Code, using the parameters contained in the Seismic Design Section of the Recommendations portion of this report, is considered appropriate. 12. Development of the subject site will not geotechnically adversely impact adjoining properties provided the recommendations of this report are implemented in design, construction and maintenance of the project. a Elan. Lot 1 May 6, 2005 Page 8 RECOMMENDATIONS SITE PREPARATION General: Except as modified by the recommendations presented in this report, all site preparation and grading should be done in accordance with Appendix D. All significant amounts of organic materials should be removed from areas to be graded. Any unsuitable earth materials in the proposed construction area should be removed to a minimum depth of 2 feet below the bottom of proposed conventional footings and recompacted to the recommended density. The recommended minimum density is 90 percent of the maximum as determined using Test Designation ASTM D 1557 -00, A designated representative of this office should approve in writing the bottom of all over - excavations prior to any fill placement. The excavated onsite soils may be used for compacted fill provided they are cleaned of deleterious materials in accordance with the recommendations of Appendix D. Estimated Shrinkage and Subsidence: A shrinkage factor of 5 to 10 percent may be utilized as an aid in estimating volume change of the materials during grading. It should be noted that these numbers are estimates only as shrinkage and subsidence are difficult to estimate accurately without extensive in -situ testing. STRUCTURAL SETBACK The bottom of all residence foundation elements should be of sufficient depth to meet the requirements of the 2001 California Building Code. The lateral distance between the lowest outside edge of the foundation element and the descending slope face must be a minimum of one -third the total height of the slope or 40 feet, whichever is greater. CONTINUOUS FOOTINGS Bearing Capacity: The allowable bearing capacity of conventional strip footings having a minimum width of 15 inches and founded a minimum of 24 inches below lowest adjacent grade in approved earth materials should not exceed 1,500 pounds per square foot. This value may be increased by one -third for short duration loading as may result from wind or seismic action. The bottoms of all footings should be placed upon a level surface. Lateral Resistance: Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of footings. For footings cast against approved earth materials, the NO Elan. Lot I May 6, 2005 Page 9 lateral bearing resistance may be computed using a value of 200 pounds per square foot, which may be increased by 200 psf for each additional foot of depth, but should not exceed 3000 pounds per square foot. A coefficient of friction of 0.35 may be used in computing the frictional resistance. It should be noted that these allowable earth material resistance parameters appropriately reflect a factor -of- safety of 1.5. Footing Reinforcement: A minimum of two No. 5 bars should be placed at the top and bottom of continuous footings in order to minimize tension cracks during seismic shaking due to subsurface imperfections. Footing Geometry: Exterior footings should be embedded a minimum of 24 inches below lowest adjacent grade in competent earth materials. Garage O nines: Footing steel and geometry should be continuous across garage door openings. Settlement: Total settlement due to structural loads is estimated not to exceed 1/4 inch for footings supported on approved earth materials. Differential settlements due to structural loads will be similar to total settlements and can be estimated to be approximately 1/4 inch over a horizontal distance of 20 feet. It is expected that settlements, should they occur, will do so essentially as the loads are applied. Potential settlement due to liquefaction under a strong seismic event is estimated to be approximately 1/4 inch. ISOLATED PAD FOOTINGS Bearing Capacity: The allowable bearing capacity of soils supporting pad footings founded a minimum of 18 inches below lowest adjacent grade in approved earth materials is 1,500 pounds per square. foot, increased by 20 percent for each additional foot of depth and/or width beyond I foot to a maximum of 4,500 pounds per square foot. This value may be increased by one -third for short duration loading as may result from wind or seismic action. The bottoms of all footings should be placed upon a level surface. �V� Elan. Lot 1 May 6, 2005 Page 10 Lateral Resistance: Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of footings. For footings cast against approved earth materials, the lateral bearing resistance may be computed using a value of 200 pounds per square foot, which may be increased by 200 psf for each additional foot of depth, but should. not exceed 3000 pounds per square foot. A coefficient of friction of 0.35 may be used in computing the frictional resistance. It should be noted that these allowable earth material resistance parameters appropriately reflect a factor -of- safety of 1.5. Pad Footing Reinforcement: A minimum grid of No. 5 bars @6 16" on- center each -way should be placed on chairs at the bottom of pad footings Pad Footing Geometry: Pad footings should be a minimum of 24 inches square and a minimum of 24 inches below lowest adjacent grade in competent earth materials. CAISSONS Vertical Bearing Capacity and Settlement: The end bearing component of the allowable bearing capacity of cast -in -place concrete caissons founded in approved soil is 1500 pounds per square foot with an allowable increase of 20 percent for each additional foot of width and /or depth beyond the minimum of 1 foot not to exceed 4500 pounds per square foot. These values may be increased, by one -third for short duration loading as may result from wind or seismic action. The frictional component of the allowable bearing capacity is 250 pounds per square foot and may be taken only in competent terrace deposits below a depth of 8-feet. Lateral Load :.Caissons cast against creep prone soils should be designed to resist a lateral load equal to 1000 pounds per linear foot of creep prone materials. For design purposes the creep zone should be computed to a depth of 4 feet below the slope surface. La Resistance: Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of caissons. For caissons cast against approved undisturbed native materials, the lateral bearing resistance may be computed using a value of 200 pounds per square foot per foot of depth below natural grade which may be increased by 200 pounds \A Elan. Lot 1 May 6, 2005 Page l l per square foot for each additional foot of depth, but should not exceed 3000 pounds per square foot. These values may be doubled for isolated conditions, defined as a minimum of 3 diameters between caissons. A coefficient of friction of 0.35 may be used in computing the frictional resistance. It should be noted that these resistant parameters appropriately reflect a factor -of- safety of 1.5. Caisson.Geometly:. Caissons should be a minimum of 24-inch diameter to facilitate down - hole inspection during the construction and should be provided with sufficient steel to meet requirements as reinforced concrete members. The structural foundation engineer will generate the anticipated depths of caissons based on structural load requirements. Actual depths of caissons may be adjusted in the field after caisson excavations are examined by the geotechnical consultant. Construction Considerations: No steel or concrete should be placed in caisson excavations until the holes are observed and approved in writing by the geotechnical consultants. All caisson excavations should be thoroughly cleaned of loose soil and debris. Should substantial volumes of groundwater be encountered, approved special drilling and installation strategies will be needed. Provisions should be made to temporarily case excavations should caving soils be encountered during construction and for downhole inspection if needed. Caissons should not be excavated within 6 feet (edge to edge) of another caisson excavation unless that caisson has been filled with concrete for more than 24 hours. RETAINING WALLS Lateral Loading on Retaining Walls: The lateral loads acting on cantilevered retaining walls backfilled with approved non - expansive granular materials such as compacted sands or gravel, having a width equal to or greater than half the retained height, can be computed using an active pressure.force equal to an equivalent fluid pressure of 35 pounds per square foot per foot of depth for level backfill and 50 pounds per square foot per foot of depth for 2 :1 (horizontal: vertical) sloping backfill. These values should be increased by 50 percent for walls structurally restrained. The on -site soils are not suitable for backfill against the wall. Jb Elan. Lot 1 May 6, 2005 Page 12 Surcharge loading: Lateral loads acting on retaining walls due to structural or vehicular surcharges should be superimposed atop the earth pressures. Lateral Resistance Design Values: Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of footings. For footings cast against approved soils, the lateral bearing resistance may be computed using a value of 200 pounds per square foot, which may be increased by 200 psf for each additional foot of depth, but should not exceed 3000 pounds per square foot. A.coefficient of friction of 0.35 may be used in computing the frictional resistance. It should be noted that these resistant parameters appropriately reflect a factor -of -safety of 1.5. In addition to the soil loading, the retaining walls should be designed to support any adjacent structural or vehicular surcharge loading that occurs within a 45- degree plane of the base of the wall. Vertical Bearing Design Values: The allowable bearing capacity of soils supporting retaining wall footings founded atop approved earth materials is 1,500 pounds per square foot, increased by 20 percent for each additional foot of depth and/or width beyond 1 foot to a maximum of 4,500 pounds per square foot. This value may be increased by one -third for short duration loading as may result from wind or seismic action. The bottoms of all footings should be placed upon a level surface. S ins• A recommended drainage design for achieving control of seepage forces behind retaining walls is shown on Figure 8. This design consists of single sized gravel wrapped with geotextile fabric separator or graded washed gravel placed in contact with undisturbed native material. Collection is with a flinch diameter perforated pipe embedded at the base of the gravel tied to a 4 -inch diameter non - perforated outlet pipe which discharges at convenient locations selected during foundation plan review. The pipe should be placed such that the gradient is not less than 0.01 ft. /ft. The fabric wrapped gravel envelope should be placed at a similar gradient. The drain should have a minimum of 2 cubic feet per foot of gravel. All subdrain pipes should be SDR -35 or approved equivalent. Perforations may be either bored holes not less than 3/16 -inch or larger than 1/2 -inch diameter or 1/8 -inch slots placed -11 Elan. Lot 1 May 6, 2005 Page 13 on the bottom one -third of the pipe perimeter. If the pipe is to be bored, a minimum of 5 holes should be uniformly placed per foot of length. Slots should not exceed 2 inches in length and total length of slots should not be less than 50 percent of the pipe length. The geotextile filter fabric should be in accordance with Orange County Standard Plan 808. The fabric pore spaces should be between 30 and 100 mesh openings. The fabric should be placed such that a minimum lap of 6 inches exists at all splices. The fabric wrapped gravel envelope should consist of 112 -inch minimum single size drain rock. All subdrain installations should be inspected by this office or designated representative. Waterproofing All interior building retaining walls should be protected from moisture penetration with a suitable waterproofing method specified by the project architect or a qualified experienced professional. Wall Backfill: Approved on -site soils may be used for the select backfill zone that is adjacent to the wall. Approved self- compacting gravel backfill may be placed in quantity behind the walls. All other materials should be.placed in 6 to 8 inch loose lifts and mechanically compacted to at least 90 percent of ASTM - 1557 -00 maximum density. Notification of this office is required prior to all retaining wall backfill operations. SEISMIC DESIGN Seismic Design in accordance with the 2001 California Building Code, should use the following criteria: 2001 CBC Table No. Factor 16-I Seismic Zone Factor, Z 0.40 16-J Soil Profile Type Sd 16 -Q Seismic Coefficient, Ca 0.44 Na 16 -R Seismic Coefficient, Cv 0.64 Nv 16 -S Near - Source Factor, Na 1.3 16 -T Near- Source Factor, Nv 1.6 16 -U Seismic Source type B /I?- Elan. Lot I May 6, 2005 Page 14 CONCRETE Results of site specific Sulfate Ion Tests indicate a "Negligible" sulfate exposure classification in accordance with Table 19 -A-4 of the 1997 UBC (2001 CBC). While no requirements are imposed by the Uniform Building Code, the use of Type V Cement for all concrete in contact with earth materials is considered prudent. TEMPORARY EXCAVATIONS All temporary excavations should be in accordance with CaIOSHA requirements and applicable governing agency grading and building codes. Any excavation over 5 feet in height should be constructed at a 1:1 (horizontal: vertical) slope, or shored. Any excavations that extend below an imaginary 1:1 plane projected from the bottom of any existing structure footing or utility should also be shored or slot cut. The contractor is entirely responsible for the job site conditions during the entire course of construction, including insuring lateral support to and protection of existing structures and property DRIVEWAY AND HARDSCAPE SLABS Subgrade soils beneath driveway and hardscape flatwork elements should be overexcavated a minimum of 12 inches below the bottom of the element and recompacted to at least 90 percent of maximum density as determined by test designation ASTM 1557 -00. Exterior slabs should have a minimum thickness of 4 inches and be reinforced with a minimum of #3 bars at 12 inches on- center each -way located at the center of the slab. The outer 8 -inch edge of driveways and patio slabs should be thickened to a minimum of 8 inches. HARDSCAPE FOOTINGS All hardscape elements supported on footings should be founded entirely in approved soils. Footings founded in soils may be designed for a vertical allowable bearing capacity of 1,500 pounds per square foot. These values may be increased by one -third for short duration loading, as may result from wind or seismic action. Lateral loads may be resisted by a passive pressure force equal to 150 pounds per square foot for footings founded in approved soils. A friction coefficient of 0.25 may be used for soil. The bottoms of all footings should be placed upon a level surface. All hardscape footings should be reinforced with a minimum of four number 4 bars, two top and two bottom. /\3 Elan. Lot I May 6, 2005 Page 15 SWIMMING POOL AND SPA The structural design of swimming pool and spa shells should meet the requirements of Section 1919 of the 1997 Uniform Building Code. Care should be taken during excavation of the pool and /or spa to minimize disturbance of support soils. If a transition in support conditions is exposed during excavation, then the entire base of the support soils should be overexcavated and recompacted a minimum of 2 feet below the bottom of the proposed shell. Observations and/or tests should be performed by the geotechnical consultants to verify that exposed soil conditions are consistent with design assumptions. Bearing Capacity: The allowable bearing capacity of approved soils supporting pool and spa shells is 1,500 pounds per square foot, increased by 20 percent for each additional foot of depth beyond I foot to a maximum of 4,500 pounds per square foot. Settlement: Total settlement due to structural loads is estimated not to exceed 1/4 inch. Differential settlements can be estimated to be approximately 114 inch over a horizontal distance of 20 feet. It is expected that settlements, should they occur, will do so essentially as the loads are applied. Lateral loads: Pool walls should be designed to withstand lateral soil loads equal to an equivalent fluid pressure of 55 pounds per square foot per foot of depth for walls gunited or cast against excavations in existing soils. These values should be increased by 50 percent for walls structurally restrained. In addition to the soil loading, the pool or spa walls should be designed to support any adjacent structural surcharge loading that occurs within a 45- degree plane of the base of the wall. Lateral resistance: Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of the pool or spa. For pools cast against approved soils, the lateral bearing resistance may be computed using a value of 200 pounds per square foot, which may be increased by 200 psf for each additional foot of depth, but should not exceed 3000 pounds per square foot. Lateral resistance should not be taken for any soils subject to slope creep (within 4 feet of slope surface). A coefficient of friction of 0.25 may be used in computing the frictional resistance. It should be noted that these resistant parameters appropriately reflect a factor -of- safety of 1.5. F� Elan. Lot 1 May 6, 2005 Page 16 Setback: The swimming pool and /or spa should be founded in competent earth materials such that a minimum horizontal distance between the outer lowermost portion of the pool foundation and the descending slope face is at least one -sixth the height of the slope or 20 feet, whichever is less. Caisson support may be needed for the proposed pool. LANDSCAPING Landscaping and irrigation should implemented in a manner that mitigates the impact on foundation and hardscape elements and the earth materials supporting these elements. Trees or bushes that develop large root systems or that require significant water should be avoided near foundations and hardscape flatwork. Variations in moisture content can severely impact the characteristics and strength of earth materials. Planter areas adjacent to structures should be designed such that foundation support soils are protected from saturation. Drainage patterns approved for the project should be maintained throughout the life of the project. Slopes and graded areas should be planted as soon as is practical with suitable ground cover and plants as recommended by an experienced landscape design professional and/or is in accordance with the governing jurisdictional agency. UTILITY TRENCHES Utility trenches should be backfilled with clean sand, gravel, or approved soils. The soil materials should be compacted to a density at least equal to 90 percent of the maximum density as determined by test designation ASTM 1557 -00. Contractors should keep detailed records /map of the location and depths of all underground utility lines installed. Notification of this office is required prior to any utility line backfill operations. DRAINAGE RUNOFF Water should not be permitted to pond adjacent to the structure. All runoff water should drain positively (solid pipe) to the street or alley. ROOF DRAINAGE The finished structure should be equipped with eaves, troughs and downspouts that collect roof runoff and conduct it to pipes or other non - erosive drainage devices through which it can be directed to the street or alley. '5 Elan. Lot 1 May 6, 2005 Page 17 REVIEW The undersigned should review and approve in writing the final project grading and foundation plans to confirm compliance with the geotechnical recommendations. FIELD INSPECTIONS Observations and tests should be made during construction to confirm the project geotechnical recommendations are properly implemented. These inspections should occur: following excavations for all overexcavation bottoms prior to placement of fill, during any fill placement and compaction, following retaining wall subdrain installation, during retaining wall backfill operations, during all utility trench backfill placement and compaction; during caisson excavations, following footing excavations prior to steel placement, and following slab subgrade preparation. The above inspections and testing conducted during construction; as well as, attending pre -grade meetings or responses to agency review items are beyond the scope and budget of this investigation and will be billed on a time and materials basis in accordance with our most recent Fee Schedule. Timely notification (48 hours) of the geotechnical phases of construction is the responsibility of the client or their representative. The above construction inspections do not supersede or replace any normally required certified independent inspections or agency inspections. PRE - CONSTRUCTION MEETING A pre- construction conference should be held with representatives of the owner, contractor, architect, civil engineer, soil engineer, geologist and building official representative prior to commencement of grading to clarify any questions relating to the intent of these recommendations and to coordinate the necessary construction inspections. MAINTANENCE AND FUTRE INPROVEMENTS Throughout the life of the project, regular site maintenance should be conducted to insure that drainage components are clean of obstructions and that they properly control surface waters. Any alteration of drainage patterns or landscape features may result in adverse conditions that can affect the performance of the proposed development. Landscaping installations should be maintained in a manner that does not allow water to pond near sloped 'I IP Elan. Lot 1 May 6, 2005 Page 18 areas or in areas adjacent to structures, and that generally protects the surface of slopes from erosional damage. Site and slope maintenance guidelines are attached in Appendix F. The recommendations of this report are specific to the current scope of the project as discussed herein. Any future proposed improvements or changes to site conditions would require additional geotechnical evaluation and possibly additional investigation. CLOSURE This investigation was conducted in accordance with generally accepted practice in the geotechnical field, as currently practiced in this or similar localities. Proper implementation of the recommendations of this report should provide suitable performance for the lifetime of the project. No expressed or implied warranty is made regarding the use of the contents of this report. The conclusions and recommendations presented in this report are based on surface and subsurface conditions encountered and the present state of geotechnical knowledge. The results of and conclusions drawn from observations made, tests conducted and information obtained for this report, are believed to be representative of the site conditions impacting the proposed project. Subsurface conditions may vary between observation points. Should conditions be revealed that are at variance with the findings of this report, such conditions will need to be evaluated by the geotechnical consultants with supplemental recommendations possibly resulting. As site , geotechnical conditions may alter with time, the recommendations presented in this report are considered valid for a period of one year from the report date. This, report is intended for the specific currently proposed development by our client and is to be used only as necessary to obtain permits and for the design and construction of said development. Changes in the proposed land use or development may require supplemental investigations or recommendations. This report is intended for the sole use of our client in conjunction with the undersigned and may not be assigned or transferred, or any portion thereof be assigned or transferred, to a third party without written permission and consent from this office. Any independent use of this report, in any form, is not valid unless specific, written verification of the applicability of the recommendations is obtained from this office. /)I Elan. Lot 1 May 6, 2005 Page 19 Thank you for the opportunity to be of service. If you have any questions, please call. Respectfully Submitted, GOC/3� David A. Purkis Civil Engineer (RCE 42810) . . Expires 3 -31 -06 A. Distribution: Addressee (5) w No.42810 d Fxp.03 -31.06 l�l ! Ian S. Kennedy Engineering Geologist (CEG 1057) Expires 1 -31 -06 r-- NO. 1057 CERTIFIED V'4GF';EERi't 'J� DAVID A. PURKIS, PE Consulting Civil Engineer May 6, 2005 Project No. 05 -1647 TO: Elan Enterprises Inc. 1380 Moorea Laguna Beach, CA 92651 Attention: Kaveh Lahijani SUBJECT: Preliminary Geotechnical Investigation for Foundation Design Residential Development of Lot 2 of 2961 Cliff Drive, Newport Beach, California INTRODUCTION The results and recommendations of our preliminary geotechnical investigation, pertinent to proposed residential development of the subject property, are provided herein. The investigation has addressed the distribution and engineering properties of earth materials in order to develop appropriate conclusions regarding the proposed development and to provide recommendations for design and construction. A topographic survey (Reference 1) depicting the proposed development was used as a base map (Plate 1) to plot the locations of exploratory excavations and geologic data for the subject site. Conclusions and recommendations herein are pertinent to construction of a new single - family residence as depicted on Plate 1. Grading and foundation plans are not available at this time and will utilize portions of this report for their preparation. This office should review these plans to determine the applicability of the contents of this report. This investigation was conducted in conjunction with the adjacent lot (Lot 1 of 2961 Cliff Drive). SCOPE OF WORK The investigation included: 1. Geotechnical reconnaissance of the subject site. 2. One exploratory boring drilled with a truck mounted bucket auger. 3. Four exploratory trenches excavated by hand. 4. Core and bulk sampling of representative earth materials from the excavations. 5. Laboratory testing of representative samples. 6. Engineering and geotechnical analysis. 7. Preparation of this report and the accompanying illustrations. 2377 S. EL CAMINO REAL #203, SAN CLEMENTE, CA 92672 - 949.369.9701 • fax 949.661.1562 H Elan. Lot 2 May 6, 2005 Page 2 ACCOMPANYING ILLUSTRATIONS AND APPENDICES Figure 1 Site Location Map Figure 2 Geologic Map (Morton & Miller, 1981) Figure 3 - Geologic Map (Fife, 1973) Figure 4 - Regional Fault Map Figure 5 - Active Fault Near - Source Zones Map Figure 6 - Seismic Hazard Zones.Map Figure 7 - USGS Ground Acceleration Lookup Results Figure 8 - Typical Retaining Wall Subdrain Detail Appendix A - Logs of Exploratory Borings Appendix B - Exploration, Field and Laboratory Testing Appendix C - List of References Appendix D - Standard Grading Specifications Appendix E - Guidelines for General Site Maintenance Plate 1 - Geotechnical Plot Plan Plate 2 - Geotechnical Cross Sections SITE DESCRIPTION The subject site is an irregular shaped lot with an approximate area of 10,000 square feet and is approximately half of a proposed lot split of the existing property. The site is comprised of sloping ground, descending from Santa Ana Avenue on the northwest to Avon Street below. Lot 1 of 2961 Cliff Drive, which is proposed to be developed in conjunction with the subject lot, is to the northeast. The subject property is presently undeveloped with grasses and some trees on it. The site is located at approximately N33.62° latitude by W117.93' longitude. PROPOSED DEVELOPMENT Based on Reference 1, the proposed development will consist of a multiple -level residence with associated hardscape and landscape elements. The approximate location of the proposed residence is depicted on Plates 1 & 2. Elan. Lot 2 May 6, 2005 Page 3 SURFACE DRAINAGE The surface runoff associated with the site is essentially that which falls directly on the lot as precipitation. Surface water collected on the site should be directed to the street or a suitable storm drainage collection. INVESTIGATION FIELD EXPLORATION One exploratory boring and four exploratory trenches were excavated at the subject site to the approximate depths and at the approximate locations shown in Appendix A and on Plate 1. Core and bulk samples obtained for laboratory testing and analysis. The excavations were logged following excavation. The logs of the borings are included in Appendix A. A more detailed description of the field sampling process is contained in appendix B. LABORATORY TESTING Laboratory testing consisted of moisture /density, maximum densityloptimum moisture, grain size, direct shear, expansion index and sulfate ion determinations. Testing procedures and test results are contained in Appendix B. Certain of the results are also contained on the trench logs in Appendix A. GEOTECHNICAL CONDITIONS GEOLOGIC SETTING The City of Newport Beach is situated on the southwesterly' slope of the San Joaquin Hills that descends south to southwesterly to the Pacific Ocean with a coastal zone comprised of wave -cut terraces that slope gently. The subject site is situated on the coastal terrace at roughly 70 feet above sea level. The terraces in the region of the subject site were cut in sedimentary bedrock, which has been assigned to the Monterey or Capistrano Formation of Miocene age (Reference 4). Wave - transported sediments (principally medium to fine sands) were deposited on the terraces as they were cut. �t Elan. Lot 2 May 6, 2005 Page 4 EARTH MATERIALS Based on a review of the literature, geologic maps, field observations and subsurface exploration (Appendix A), the following geologic units were observed or noted: Artificial Fill (Af) ! Residual Soils (Qrs) Surficial earth materials consisting of artificial fill and undifferentiated residual soils that extend approximately 15 feet below the existing pad on the property. These soils are reddish brown, silty sands that are moist and medium dense to dense. The upper portions of these soils are not suitable for foundation support without reprocessing and recompacting. Marine Terrace Deposit (Ot m) Lying beneath the surface soils are Marine Terrace Deposits consisting of gray brown fine to coarse sands and silty sands. These materials are moist and dense to very dense. Based on regional mapping, the bedrock underlying the site at depth is assigned to the Monterey Formation or the Capistrano Formation, which are sedimentary rock of marine origin and of Miocene age. The bedrock was not encountered in the exploratory excavations. Competent terrace deposits, certified fill and /or approved soils are suitable for support of proposed building loads. SURFICAL RUNOFF No evidence of former uncontrolled runoff onto or from the site has been observed. The proposed development on the relatively flat lot is not anticipated to adversely impact surrounding properties, provided proper civil engineering design for the control of drainage is implemented. GROUND WATER Groundwater was not encountered in any of the exploratory excavations made during this investigation and is not anticipated to be a constraint to construction. G f I Elan. Lot 2 May 6, 2005 Page 5 LIQUEFACTION AND LANDSLIDES The subject site is not located in a seismic hazard zone as depicted on Reference 5 by the California Department of Conservation (refer to Figure 6). This reference depicts zones of required investigation for Liquefaction or Earthquake - Induced Landslides in the Newport Beach Quadrangle. Reference 8 defines these areas as: "Areas where historical occurrence of liquefaction / landslide movement, or local geological, geotechnical and groundwater/ subsurface water conditions indicate a potential for permanent ground displacements such that mitikation as defined in Public Resources Code section 2983 (c) would be required ". However, the base of the slope near Pacific Coast Highway is depicted as a zone of potential liquefaction. Site - specific exploration indicates that there is a lack of groundwater in the upper 50 feet of the subject site, therefore, the potential for liquefaction is considered remote. No slumps or landslides that may impact the site were noted in the study area during our investigation or on any of the reviewed referenced publications. The non - cohesive soils that comprise the lower slopes may experience localized surficial instability. Surficial slope conditions are not anticipated to be problematic to the proposed development provided adequate setback of foundation elements as recommended herein are utilized in design and construction. SEISMIC CONSIDERATIONS There are no active faults observed or previously mapped that pass through the site. The nearest active fault is the Newport Inglewood Fault (NIF) [refer to Figure 41. The Newport- Inglewood Fault Zone could produce an earthquake of magnitude 6.9 (Reference 11) with local strong ground motion equivalent to at least VIII on the modified Mercalli Scale. The Southern California area is susceptible to strong shaking from earthquakes originating from the NIF, the Elsinore Whittier Fault, the San Jacinto Fault and the San Andreas Fault (Figures 4 & 5). A large earthquake, magnitude 6.3 occurred off Newport Beach on March 11, 1933, and more recently a 4.6 to 4.9 magnitude earthquake occurred just offshore from Newport Beach on April 7, 1989. Both of these earthquake epicenters were on the NIF. In Laguna Beach a 4.5 magnitude earthquake occurred on October 27, 1969. The epicenter was located 1000 feet offshore of Crescent Bay. From 1934 to 1937, earthquakes with Elan. Lot 2 May 6, 2005 Page 6 epicenters west of Emerald Bay and magnitudes ranging from 1.5 to 2.0 were reported. In 1812, an earthquake of sufficient magnitude to destroy the mission occurred in San Juan Capistrano. The Probalistic Seismic Hazard Mapping Ground Motion website of the California Geologic Survey returns a Peak Ground Acceleration value of 0.43g (alluvium site) for 10 percent probable exceedance in .a 50 year period for the site's global coordinates (refer to Figure 7). The Active Fault Near - Source Zone Map, N -34 (Figure 5) indicates the site is located approximately 1.5 Kilometers from the Newport Inglewood fault. The Newport Inglewood fault is identified as a "Type B" fault, capable of a Moment Magnitude 6.9 earthquake. In summary, this property is not subject to any special seismic hazards as compared to other nearby residences in similar geologic environments. Ground rupture or liquefaction as a result of seismic shaking is remote. There is no evidence of active faulting or ground rupture on the site. Seismic design in accordance with the latest edition of the California Building Code using the parameters provided in the recommendation section of this report . is considered appropriate. CONCLUSIONS 1. A proposed residential development can be feasible and safe from a geotechnical viewpoint . provided it is done in accordance with the conclusions and recommendations provided herein and that this office is retained during the design and construction phases to assure conformance with these requirements. 2. A multiple story wood framed single - family residence is proposed for the subject lot. 3. Earth materials underlying the proposed development area, as revealed in the exploratory excavations and as depicted in literature consist of surficial soils and Terrace Deposits atop bedrock of the Monterey or Capistrano Formations. ,�A Elan. Lot 2 May 6, 2005 Page 7 4. Groundwater was not encountered at the site and is not anticipated to be a development or construction constraint. 5. Unapproved soils in areas supporting structural elements should be removed and recompacted to a minimum depth of two feet below the bottoms of proposed footings. 6. Competent approved native or certified fill soils will be suitable for support of foundation elements. All slabs and footings should be designed in accordance with the recommendations of this report to mitigate against substrata imperfections and seismic shaking. 7. Results of laboratory tests indicate very low expansion potential for near surface soils in accordance with Table 18 -1 -B of the 2001 California Building Code (CBC). 8. Results of laboratory tests indicate a negligible sulfate exposure classification in accordance with Table 19 -A-4 of the CBC. 9. Earth materials at the subject site should excavate readily with conventional construction equipment. 10. Fault rupture across the property is not anticipated. Liquefaction is considered remote. 11. Seismic design in accordance with the latest edition of the California Building Code, using the parameters contained in the Seismic Design Section of the Recommendations portion of this report, is considered appropriate. 12. Development of the subject site will not geotechnically adversely impact adjoining properties provided the recommendations of this report are implemented in design, construction and maintenance of the project. 0 Elan. Lot 2 May 6, 2005 Page 8 SITE PREPARATION General: Except as modified by the recommendations presented in this report, all site preparation and grading should be done in accordance with Appendix D. All significant amounts of organic materials should be removed from areas to be graded. Any unsuitable earth materials in the proposed construction area should be removed to a minimum depth of 2 feet below the bottom of proposed conventional footings and recompacted to the recommended density. The recommended minimum density is 90 percent of the maximum as determined using Test Designation ASTM D 1557 -00. A designated representative of this office should approve in writing the bottom of all over - excavations prior to any fill placement. The excavated onsite soils may be used for compacted fill provided they are cleaned of deleterious materials in accordance with the recommendations of Appendix D. Estimated Shrinkage and Subsidence: A shrinkage factor of 5 to 10 percent may be utilized as an aid in estimating volume change of the materials during grading. It should be noted that these numbers are estimates only as shrinkage and subsidence are difficult to estimate accurately without extensive in -situ testing. STRUCTURAL SETBACK The bottom of all residence foundation elements should be of sufficient depth to meet the requirements of the 2001 California Building Code: The lateral distance between the lowest outside edge of the foundation element and the descending slope face must be a minimum of one -third the total height of the slope or 40 feet, whichever is greater. CONTINUOUS FOOTINGS Bearing Capacity: The allowable bearing capacity of conventional strip footings having a minimum width of 15 inches and,founded a minimum of 24 inches below lowest adjacent grade in approved earth materials should not. exceed 1,500 pounds per square foot. This value may be increased by one -third for short duration loading as may result from wind or seismic action. The bottoms of all footings. should be placed upon a level surface. Lateral Resistance: Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of footings. For footings cast against approved earth materials, the CA(_Q Elan. Lot 2 May 6, 2005 Page 9 lateral bearing resistance may be computed using a value of 200 pounds per square foot, which may be increased by 200 psf for each additional foot of depth, but should not exceed 3000 pounds per square foot. A coefficient of friction of 0.35 may be used in computing the frictional resistance. It should be noted that these allowable earth material resistance parameters appropriately reflect a factor -of- safety of 1.5. Footing Reinforcement: A minimum of two No. 5 bars should be placed at the top and bottom of continuous footings in order to minimize tension cracks during seismic shaking due to subsurface imperfections. Footing Geometry: Exterior footings should be embedded a minimum of 24 inches below lowest adjacent grade in competent earth materials. Garage Openings Footing steel and geometry should be continuous across garage door openings. Settlement: Total settlement due to structural loads is estimated not to exceed 1/4 inch for footings supported on approved earth materials. Differential settlements due to structural loads will be similar to total settlements and can be estimated to be approximately 1/4 inch over a horizontal distance of 20 feet. It is expected that settlements, should they occur, will do so essentially as the loads are applied. Potential settlement due to liquefaction under a strong seismic event is estimated to be approximately 1/4 inch. ISOLATED PAD FOOTINGS Bearing Capacity: The allowable bearing capacity of soils supporting pad footings founded a minimum of 18 inches below lowest adjacent grade in approved earth materials is 1,500 pounds per square foot, increased by 20 percent for each additional foot of depth and/or width beyond I foot to a maximum of 4,500 pounds per square foot. This value may be increased by one -third for short duration loading as may result from wind or seismic action. The bottoms of all footings should be placed upon a level surface. %I Elan. Lot 2 May 6, 2005 Page 10 Lateral Resistance: Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of footings. For footings cast against approved earth materials, the lateral beating resistance may be computed using a value of 200 pounds per square foot, which. may be increased by 200 psf for each additional foot of depth, but should not exceed 3000 pounds per square foot. A coefficient of friction of 0.35 may be used in computing the frictional resistance. It should be noted that these allowable earth material resistance parameters appropriately reflect a factor -of- safety of 1.5. Pad Footing Reinforcement A minimum grid of No. 5 bars @ 16" on- center each -way should be placed on chairs at the bottom of pad footings Pad Footing Geometry Pad footings should be a minimum of 24 inches square and a minimum of 24 inches below lowest adjacent grade in competent earth materials. CAISSONS Vertical Bearing Cap-a-613! and Settlement: The end bearing component of the allowable bearing capacity of cast -in -place concrete caissons founded in approved soil is 1500 pounds per square foot with an allowable increase of 20 percent for each additional foot of width and/or depth beyond the minimum of 1 foot not to exceed 4500 pounds per square foot. These values may be increased by one -third for short duration loading as may result from wind or seismic action. The frictional component of the allowable bearing capacity is 250 pounds per square foot and may be taken only in competent terrace deposits below a depth of 8 feet. Lateral Loads: Caissons cast against creep prone soils should be designed to resist a lateral load equal to 1000 pounds per linear foot of creep prone materials. For design purposes the creep zone should be computed to a depth. of 4 feet below the slope surface. Lateral Resistance: Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of caissons. For caissons cast.against approved undisturbed native materials, the lateral bearing resistance may be computed.using a value of 200 pounds per square foot per foot of depth below natural grade which may be increased by 200 pounds Elan. L.ot 2 May 6, 2005 Page I1 per square foot for each additional foot of depth, but should not exceed 3000 pounds per square foot. These values may be doubled for isolated conditions, defined as a minimum of 3 diameters between caissons. A coefficient of friction of 0.35 may be used in computing the frictional resistance. It should be noted that these resistant parameters appropriately reflect a factor -of -safety of 1.5. Caisson Geometry: Caissons should be a minimum of 24 -inch diameter to facilitate down - hole inspection during the construction and should be provided with sufficient steel to meet requirements as reinforced concrete members. The structural foundation engineer will generate the anticipated depths of caissons based on structural load requirements. Actual depths of caissons may be adjusted in the field after caisson excavations are examined by the geotechnical consultant. Construction Considerations: No steel or concrete should be placed in caisson excavations until the holes are observed and approved in writing by the geotechnical consultants. All caisson excavations should be thoroughly cleaned of loose soil and debris. Should substantial volumes of groundwater be encountered, approved special drilling and installation strategies will be needed. Provisions should be made to temporarily case excavations should caving soils be encountered during construction and for downhole inspection if needed. Caissons should not be excavated within 6 feet (edge to edge) of another caisson excavation unless that caisson has been filled with concrete for more than 24 hours. RETAINING WALLS Lateral Loading on Retaining Walla: The lateral loads acting on cantilevered retaining walls backEilled with approved non - expansive granular materials such as compacted sands or gravel, having a width equal to or greater than half the retained height, can be computed using an active pressure force equal to an equivalent fluid pressure of 35 pounds per square foot per foot of depth for level backfill and 50 pounds per square foot per foot of depth for 2:1 (horizontal: vertical) sloping backfill. These values should be increased by 50 percent for walls structurally restrained. The on -site soils are not suitable for backfill against the wall. Elan. Lot 2 May 6, 2005 Page 12 Surcharge loading: Lateral loads acting on retaining walls due to structural or vehicular surcharges should be superimposed atop the earth pressures. Lateral Resistance Design Values: Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of footings. For footings cast against approved soils, the lateral bearing resistance may be computed using a value of 200 pounds per square foot, which may be increased by 200 psf for each additional foot of depth, but should not exceed 3000 pounds per square foot. A coefficient of friction of 0.35 may be used in computing the frictional resistance. It should be noted that these resistant parameters appropriately reflect a factor -of- safety of 1.5. In addition to the soil loading, the retaining walls should be designed to support any adjacent structural or vehicular surcharge loading that occurs within a 45- degree plane of the base of the wall. Vertical Bearing Design Values: The allowable bearing capacity of soils supporting retaining wall footings founded atop approved earth materials is 1,500 pounds, per square foot, increased by 20 percent for each additional foot of depth and /or width beyond 1 foot to a maximum of 4,500 pounds per square foot. This value may be increased by one -third for short duration loading as may result from wind or seismic action. The bottoms of all footings should be placed upon a level surface. Subdrains: A recommended drainage design for achieving control of seepage forces behind retaining walls is shown on Figure 8. This design consists of single sized gravel wrapped with geotextile fabric separator or graded washed gravel placed in contact with undisturbed native material. Collection is with a flinch diameter perforated pipe embedded at the base of the gravel tied to a 4 -inch diameter non - perforated outlet pipe which discharges at convenient locations selected during foundation plan review. The pipe should be placed such that the gradient is not less than 0.01 ft. /ft. The fabric wrapped gravel envelope should be placed at a similar gradient. The drain should have a minimum of 2 cubic feet per foot of gravel. All subdrain pipes should be SDR -35 or approved equivalent. Perforations may be either bored holes not less than 3/16 -inch or larger than 1/2 -inch diameter or 1/8 -inch slots placed Elan. Lot 2 May 6, 2005 Page 13 on the bottom one -third of the pipe perimeter. If the pipe is to be bored, a minimum of 5 holes should be uniformly placed per foot of length. Slots should not exceed 2 inches in length and total length of slots should not be less than 50 percent of the pipe length. The geotextile filter fabric should be in accordance with Orange County Standard Plan 808. The fabric pore spaces should be between 30 and 100 mesh openings. The fabric should be placed such that a minimum lap of 6 inches exists at all splices. The fabric wrapped gravel envelope should consist of 112 -inch minimum single size drain rock. All subdrain installations should be inspected by this office or designated representative. Waterproofing: All interior building retaining walls should be protected from moisture penetration with a suitable waterproofing method specified by the project architect or a qualified experienced professional'. Wall Backfill: Approved on -site soils may be used for the select backfill zone that is adjacent to the wall. Approved self - compacting gravel backfill may be placed in quantity behind the walls. All other materials should be placed in 6 to 8 inch loose lifts and mechanically compacted to at least 90 percent of ASTM - 1557 -00 maximum density. Notification of this office is required prior to all retaining wall backfill operations. SEISMIC DESIGN Seismic Design in accordance with the 2001 California Building Code, should use the following criteria: 2001 CBC Table No. Factor 16 -I Seismic Zone Factor, Z 0.40 16 -J Soil Profile Type Sd 16 -Q Seismic Coefficient, Ca 0.44 Na 16 -R Seismic Coefficient, Cv 0.64 Nv 16 -S Near- Source Factor, Na 1.3 16-T Near - Source Factor, Nv 1.6 16-U Seismic Source type B Flan. Lot 2 May 6, 2005 Page 14 CONCRETE Results of site specific Sulfate Ion Tests indicate a "Negligible" sulfate exposure classification in accordance with Table 19 -A -4 of the 1997 UBC (2001 CBC). While no requirements are imposed by the Uniform Building Code, the use of Type V Cement for all concrete in contact with earth materials is considered prudent. TEMPORARY EXCAVATIONS All temporary excavations should be in accordance with CalOSHA requirements and applicable governing agency grading and building codes. Any excavation over 5 feet in height should be constructed at a 1:1 (horizontal: vertical) slope, or shored. Any excavations that extend below an imaginary 1:1 plane projected from the bottom of any existing structure footing or utility should also be shored or slot cut. The contractor is entirely responsible for the job site conditions during the entire course of construction, including insuring lateral support to and protection of existing structures and property. DRIVEWAY AND HARDSCAPE SLABS Subgrade soils beneath driveway and hardscape flatwork elements should be overexcavated a minimum of 12 inches below the bottom of the element and recompacted to at least 90 percent of maximum density as determined by test designation ASTM 1557 -00. Exterior slabs should have a minimum thickness of 4 inches and be reinforced with a minimum of #3 bars at 12 inches on- center each -way located at the center of the slab. The outer 8 -inch edge of driveways and.patio slabs should be thickened to a minimum of 8 inches. HARDSCAPE FOOTINGS All hardscape elements supported on footings should be founded entirely in approved soils. Footings founded in soils may be designed for a vertical allowable bearing capacity of 1,500 pounds per square foot. These values may be increased by one -third for short duration loading, as may result from wind or seismic action. Lateral loads may be resisted by a passive pressure force equal to 150 pounds per square foot for footings founded in approved soils. A friction coefficient of 0.25 may be used for soil. The bottoms of all footings should be placed upon a level surface. All hardscape footings should be reinforced with a minimum of four number 4 bars, two top and two bottom. A Elan. Lot 2 May 6, 2005 Page 15 SWIMMING POOL AND SPA The structural design of swimming pool and spa shells should meet the requirements of Section 1919 of the 1997 Uniform Building Code. Care should be taken during excavation: of the pool and/or spa to minimize disturbance of support soils. If a transition in support conditions is exposed during excavation, then the entire base of the support soils should be overexcavated and recompacted a minimum of 2 feet below the bottom of the proposed shell. Observations and /or tests should be performed by the geotechnical consultants to verify that exposed soil conditions are consistent with design assumptions. Bearing Caoacity: The allowable bearing capacity of approved soils supporting pool and spa shells is 1,500 pounds per square foot, increased by 20 percent for each additional foot of depth beyond 1 foot to a maximum of 4,500 pounds per square foot. Settlement: Total settlement due to structural loads is estimated not to exceed 114 inch. Differential settlements can be estimated to be approximately 1/4 inch over a horizontal distance of 20 feet. It is expected that settlements, should they occur, will do so essentially as the loads are applied. Lateral loads: Pool walls should be designed to withstand lateral soil loads equal to an equivalent fluid pressure of 55 pounds per square foot per foot of depth for walls gunited or cast against excavations in existing soils. These values should be increased by 50 percent for walls structurally restrained. In addition to the soil loading, the pool or spa walls should be designed to support any adjacent structural surcharge loading that occurs within a 45- degree plane of the base of the wall. Lateral resistance: Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of the pool or spa. For pools cast against approved soils, the lateral bearing resistance may be computed using a value of 200 pounds per square foot, which may be increased by 200 psf for each additional foot of depth, but should not exceed 3000 pounds per square foot. Lateral resistance should not be taken for any soils subject to slope creep (within 4 feet of slope surface). A coefficient of friction of 0.25 may be used in computing the frictional resistance. It should be noted that these resistant parameters appropriately, reflect a factor -of- safety of 1.5. 0 Elan. Lot 2 May 6, 2005 Page 16 Setback : The swimming pool and /or spa should be founded in competent earth materials such that a minimum horizontal distance between the outer lowermost portion of the pool foundation and the descending slope face is at least one -sixth the height of the slope or 20 feet, whichever is less. Caisson support may be needed for the proposed pool. LANDSCAPING Landscaping and irrigation should implemented in a manner that mitigates the impact on foundation and hardscape elements and the earth materials supporting these elements. Trees or bushes that develop large root systems or that require significant water should be avoided near foundations and hardscape flatwork. Variations in moisture content can severely impact the characteristics and strength of earth materials. Planter areas adjacent to structures should be designed such that foundation support soils are protected from saturation. Drainage patterns approved for the project should be maintained throughout the life of the project. Slopes and graded areas should be planted as soon as is practical with suitable ground cover and plants as recommended by an experienced landscape design professional and/or is in accordance with the governing jurisdictional agency. UTILITY TRENCHES Utility trenches should be backfilled with clean sand, gravel, or approved soils. The soil materials should be compacted to a density at least equal to 90 percent of the maximum density as determined by test designation ASTM 1557 -00. Contractors should keep detailed records /map of the location and depths of all underground utility lines installed. Notification of this office is required prior to any utility line backfill operations. DRAINAGE RUNOFF Water should not be permitted to pond adjacent to the structure. All runoff water should drain positively (solid pipe) to the street or alley. ROOF DRAINAGE The finished structure should be equipped with eaves, troughs and downspouts that collect roof runoff and conduct it to pipes or other non- erosive drainage devices through which it can be directed to the street or alley. q.A Elan. Lot 2 May 6, 2005 Page 17 REVIEW The undersigned should review and approve in writing the final project grading and foundation plans to confirm compliance with the geotechnical recommendations. FIELD INSPECTIONS Observations and tests should be made during construction to confirm the project geotechnical recommendations are properly implemented. These inspections should occur: following excavations for all overexcavation bottoms prior to placement of fill, during any fill placement and compaction, following retaining wall subdrain installation, during retaining wall backfill operations, during all utility trench badriill placement and compaction, during caisson excavations, following footing excavations prior to steel placement, and following slab subgrade preparation. The above inspections and testing conducted during construction; as well as, attending pre -grade meetings or responses to agency review items are beyond the scope and budget of this investigation and will be billed on a time and materials basis in accordance with our most recent Fee Schedule. Timely notification (48 hours) of the geotechnical phases of construction is the responsibility of the client or their representative. The above construction inspections do not supersede or replace any normally required certified independent inspections or agency inspections. PRE- CONSTRUCTION MEETING A pre - construction conference should be held with representatives of the owner, contractor, architect, civil engineer, soil engineer, geologist and building official representative prior to commencement of grading to clarify- any questions relating to' *the intent of these recommendations and to coordinate the necessary construction inspections. MAINTANENCE AND FUTRE IMPROVEMENTS Throughout the life of the project, regular site maintenance should be conducted to insure that drainage components are clean of obstructions and that they properly control surface waters. Any alteration of drainage patterns or landscape features may result in adverse conditions that can affect the performance of the proposed development. Landscaping installations should be maintained in a manner that does not allow water to pond near sloped (0 . Elan. Lot 2 May 6, 2005 Page 18 areas or in areas adjacent to structures, and that generally protects the surface of slopes from erosional damage. Site and slope maintenance guidelines are attached in Appendix F. The recommendations of this report are specific to the current scope of the project as discussed herein. Any future proposed improvements or changes to site conditions would require additional geotechnical evaluation and possibly additional investigation. CLOSURE This investigation was conducted in accordance with generally accepted practice in the geotechnical field, as currently practiced in this or similar localities. Proper implementation of the recommendations of this report should provide suitable performance for the lifetime of the project. No expressed or implied warranty is made regarding the use of the contents of this report. The conclusions and recommendations presented in this report are based on surface and subsurface conditions encountered and the present state of geotechnical knowledge. The results of and conclusions drawn from observations made, tests conducted and information obtained for this report, are believed to be representative of the site conditions impacting the proposed project. Subsurface conditions may vary between observation points. Should conditions be revealed that are at variance with the findings of this report, such conditions will need to be evaluated by the geotechnical consultants with supplemental recommendations possibly resulting. As site geotechnical conditions may alter with time, the recommendations presented in this report are considered valid for a ` period of one year from the report date. This report is intended for the specific currently proposed development by our client and is to be used only as necessary to obtain permits and for the design and construction of said development. Changes in the proposed land use or development may require supplemental investigations or recommendations. This report is intended for the sole use of our client in conjunction with the undersigned and may not be assigned or transferred, or any portion thereof be assigned or transferred, to a third party without written permission and consent from this office. Any independent use of this report, in any form, is not valid unless specific, written verification of the applicability of the recommendations is obtained from this office. 33 Elan. Lot 2 May 6, 2005 Page 19 Thank you for the opportunity to be of service. If you have any questions, please call. Respectfully Submitted, Q cp'e David A. Purkis Civil Engineer (RCE 42810) Expires 3 -31 -06 r Distribution: Addressee (5) Ia� n ,� 5. Kennedy Engineering Geologist (CEG 1057) Expires 1 -31 -06 ro, j057 ' 4r!j�tFiEQ F fF?i�Sd�'tPlG s•_a. k�lQl��Ta ql Local Hydrology/ Hydraulic Report March 2004 Hydrology /Hydualic Report For: The Mirsafavi Residence Cliff Drive Newport Beach, CA Tentative Parcel Map No. 2005 -206 Prepared by: GILBERT ENGINEERING & ASSOCIATES. INC. 2 Merriweather Place Ladera Ranch, California 92694 . (949) 218 -8075 Project Number: 187.000 Supervising Engineer: R. William Gilbert, P.E. RCE No. 53251 Date Prepared: March 2006 Mirsafavi Residence Beach, CA K31 Local Hydrology/ Hydrauflc Report March 3006 Table of Contents 1. Introduction ..................................... ............................... 1 Geographic Setting .................................. ............................... l Purpose of This Report ...............:............... ..............................1 References................................................. ............................... l Project Site Location Map ........................ ..............................2 11. Existing Topographic & Hydrologic Conditions ...... 3 ExistingTopography ................................... ..............................3 Existing Drainage Pattern ......................... ..............................3 Existing Storm Drain Facilities .................... ..............................3 Exisfing Conditions ..................................... ..............................3 Ill. Proposed Storm Drain Facilities ... ............................... 4 IV. Hydrology Study (Local Storm Drains) ............................ 4 Storm Frequency Methodology.............................................. ..............................4 V Local Area Drain Pipe Sizing ......... ............................... 4 VI.Design Criteria ....................................... ..............................4 Excerpts from Grange County Design Manual V11. Results & Conclusions ..................... ............................... 7 Vlll. Appendices ........................................ ..............................8 Appendix 1- Figure 4-5, Runoff /Acre for Graphic Method Appendix 2- Local Area Drain Pipe Size Calculations . Appendix 3- Local Hydrology Map (In Pocket) MirsafaW Residence - Newport Beach, CA 5nD Local Hydrology/ Hydraulic Report 1. Introduction Geographic Setting The Study area consists of 2 private residential lots. The northern lot, Lot 1 is 0.34 acres± and the southern lot, Lot 2 is 0.42 acres±. The lots are located south of Cliff Drive, east of Santa Ana Ave. and north of Avon Street. East of the two lots is an existing private residence. Purpose of This Report The purpose of this report is to accomplish the following objectives: 1. To determine the storm water discharges generated within local drainage areas within the project. 2. To support the design of "local" storm drains, consisting of laterals and catch basins, as submitted with this report. 3. To demonstrate that the "storm water" and "Flood" protection goals as outlined in Addendum No. 1 to the O.C. P.F. &R.D. Design Manual have been met. References • O.C. P.F. &R.D. Hydrology Manual • O.C. P.F.&R.D. Design Manual Mirsafavi Residence Newport Beach, CA 0 � W271 Project Site Loca ■ ■on Ma Thomas Brothers, 200, Residence Newport // Local Hydrology►/ Hydraulic Report II. Existing Topographic & Hydrologic Conditions Existing Topography The site has an existing house on the northern end of the lot which will be tom down. Behind the house is a large natural slope which continues down to Avon St. Existing Drainage Pattern The site drainage presently sheet flows across the property, to the south, and down the hill where it makes its way into a small rectangular toe of slope drain which daylights into Avon Street, just east of the parcel. On the northern end of the site a small portion of drainage from the existing front yard, drains into Cliff Drive and travels down Santa Ana Ave. Existing Storm Drain Facilities All onsite drainage sheet flows around the existing house and down the hill behind it with the exception of the front yard area which flows into Cliff Drive. Existing Conditions Currently there are no signs of erosion on the site. III. Proposed Storm Drain Facilities The front yard of LOT 1 will be collect via area drains and will outlet on the northwest side of the lot via curb outlet into Santa Ana Ave using the City Standard 184-L. Bottomless trench drains will also be incorporated at the driveways. The backyard and easterly side yard will be collected in a v -ditch and will travel down the eastern property line through LOT 2 in a drainage easement. Prior to crossing Lot 2 there will be a BMP water filter device that will clean the storm water before sending it into Lot 2. All of Lot 2 will also be collected by area drains and drain into the some v -ditch on the eastern side of the property. The southern property line will also have a v -ditch which will connect with the eastern v- ditch. At the bottom of the hill the two v- ditches confluence and at this point another BMP water filter device will be placed to clean the storm water at the south eastern comer of the property. The Residence — Newport Beach, CA tib3 Local HydrolM / Hydraulic Report two v- ditches will connect to the existing rectangular drain behind the retaining wall on Avon Ave. From the point of connection, the existing rectangular drain will be enlarged to accommodate the flow from the two lots. The rectangular drain will continue to daylight into Avon Ave. as it currently does. IV. Hydrology Study (Local Storm Drains) Storm Frequency The storm frequency for this study is based on the 10 year storm Methodology This study was prepared in conformance with the Orange County Local Drainage Manual and the Hydrology Manual. Due to the small size of the private residence Method 11 (Graphic Method) was used to size the volume of runoff that would be released into the rip rap structure, Based on Figure 4-5 of the Local Drainage Manual a Q10 of 3.2 cfs was calculated per acre. The acreage tributary to the rectangular drain equals 0.76 acres, giving a total drain flow of 2.28 cfs. Ql = 0.19 cfs, Q2 = 0.90cfs and Q3 = 1.34cfs. The hydraulic analysis was performed using the Heastead Methods FlowMaster computer program which uses Manning's formula Q = A *1.486 /n *R2/3 *S112. The roughness coefficient n--0.13 for the concrete ditches and n =0.10 for the PVC pipe. V. Local Area Drain Pipe Sizing Local PVC pipes and V- ditchs were sized using a Q =3.2 cfs per acre to obtain the Q for an area. Then the maximum 0}0 capacity for a 4" pipe at a 1% (minimum) slope was calculated along with maximum capacity for a v -ditch and the existing rectangular drain along with a larger proposed drain. The full flow of a 4" PVC pipe at s= 0.0100 grade will carry Q=0.24 cfs. The proposed Al area only has Q, =0.19 cfs. Therefore a 4" pipe will be sufficient. A proposed 2' wide by V deep V -ditch flowing at s= 0.0100 grade will carry 5.72cfs which is greater than the entire site runoff at OT- 2.43cfs. The v- ditches flow at a much steeper grade so they can handle much higher Q's. For example at v -ditch flowing at a slope of s=0.0500 will carry a Q= 12.78cfs. Because none of the ditches are less than s= 0.0100 the v- Mirsafavi Residence Newport Beach, GA FDA Local Hydrology/ Hydraulic Report ditch size is sufficient. The existing rectangular channel at the bottom of the hill which will pick up the Qr= 2.43cfs from the project can only handle 2.27cfs at a s= 0.0100 grade. Therefore we recommend that the rectangular drain be replace by a 2' wide by V deep concrete drain which will handle upto Qr =14.40 cfs at a s= 0.0100 grade. VI. Design Criteria The proposed storm drain systems will be designed so as to be consistent with the following goals and guidelines: A. All buildings shall be protected from flooding during a 100 -year frequency storm because the site is not in a flood zone and overflow protection well be designed into the project. B. 1. Onsite design storm is based on a 10 -year frequency. In sump conditions for catch basins and the connecting storm drains also use a 10 -year frequency. 2. Offsite design storm frequency, subject to individual review by the City, should be in accordance with the O.C. P.F. &R.D. Hydrology Manual. C. 1. Velocity should not exceed 20 FPS in P.V.0 pipe and standard wall R.C.P. 2. Where velocity exceeds 20 FPS, a special wall R.C.P. with a minimum of I'/-inch steel clearance on the inside surface shall be used. 3. Maximum velocity in special cover R.C.P. shall be 45 FPS. D. On arterial highways, one jij 12' lane each direction should be clear of water, with a 10 -year storm. In sump conditions, a 25 -year storm event shall be used. E. On local streets, flow should not exceed top of curb, for a 10 -year storm event, and in sump conditions, a 25 -year storm event shall be used. F. Cross gutter is not allowed at any through street. G. Catch basins are to be constructed at all four corners of arterial highway intersections. H. Open cut is not allowed at any existing arterial highway. Pipe must be jacked across street. Mftafavi Residence Newport Beach. CA jP5 Local Hydrology/ Hydraulic Report I. Maximum W.S. in CB's for design conditions shall be 0.5' below inlet (FL.) elevation. J. Once water is picked up in a storm drain, it should remain in the system. K. Pipe size may not be decreased downstream without the City's approval. L. Branching of flow is not allowed. . M. Provide hydraulic and energy grade line calculations and plot of hydraulic grade line on plans with table of appropriate hydraulic data. N. The ratio of normal velocity to critical velocity should be less than 0.9 or greater than 1.2. O. All pipes and conduits laid parallel to the roadway shall be placed at least 30" below the roadway surface. However, when pipe depth is in excess of 10' (measured from top of pipe to ground surface), the City's approval is required prior to the initial design of the system. P. Junction structures should be designed according to the O.C. P.F.S,R.D. "Design Manual" or utilize City of Newport Beach Standard Plans. Q. Storm Drain Easement width shall be determined in the following manner: 1. D = 36" or smaller - Distance from top of pipe to ground level times 1.5 + diameter of pipe +2.0' (When cover exceeds 10', use 2 below.) 2. D = 39" or greater - a. Distance from bottom of pipe to ground level times 2.0 + diameter of pipe + 2.0'. In any case, the width of easement shall not be less than 10.0' in width. R. Storm drain shall be located at the center line of the easement. S. Easement shall be exclusively for storm drain purposes. T. Storm drain with high fills: 1. Fill Greater than 40 Feet Storm drains which are installed with cover greater than 40 feet shall have a diameter a minimum of 12 inches larger than that required for hydraulic adequacy and shall be constructed using pre - stressed concrete pipe." Newport Beach, CA 10 (D Local Hydrology/ Hydraulic Report Storm drains which are installed with cover between 30 and 40 feet shall have a diameter a minimum of 12 inches larger than that required for hydraulic adequacy and shall be constructed using pre- stressed concrete pipe if the subgrade of the pipe is in a fill area' If subgrade is in native soil, reinforced concrete pipe may be used. 3. Fill Between 20 and 30 Feet Storm drains which are installed with cover between 20 and 30 feet shall be constructed using reinforced concrete pipe. A pipe diameter greater than that required for hydraulic adequacy may be required if, in the opinion of the City Engineer's staff, the particular conditions involved warrant the larger size. 4. Fill Less Than 20 Feet Normal criteria for storm drain design shall be followed. Exceptions may be made for a roadway crossing of a natural watercourse which will remain undisturbed with future development. VII. Results and Conclusions This report's purpose was to size the proposed storm drain system only. The drainage patterns or direction of flow did not change from the existing to the proposed. Based on our calculations, it is our opinion that the proposed storm drain system designed to a Qt0 Storm Frequency is adequate to transport the drainage off site and that for a. 010() storm frequency there should be no damage to the proposed structures. Mirsafavi Residence Newport Beach. CA 161 Local Hydrology/ Hydraulic Report VIII. Appendices Appendix I - Figure 45, Runoff /Acre for Graphic Method Appendix 2 - Area Drain Pipe Size Calculations Appendix 3 - Local Hydrology Map Mirs0avi Residence Newport Beach, CA `a §§ 0 z O-C Z w a ;3,4 NZ zw - \4-21 !6L }� } )�!� }} }!� � !�!) :� ���| {} ���! �� ���) �� ���� � ���� � � .- - ! �� z z {} { }�� }�!� }� {� }��� }� {� � ���� � _��� �� :�� ���� �� {� ���� �_ �l�� |��� ��� ���� ���� ���� :��� ��!! ���� t t TTM %4J Nil to C3, 16 16 C2, C3, am r� to W) Ck ■M CQ Nso — v Uw, lz ■ §§ 0 z O-C Z w a ;3,4 NZ zw - \4-21 §§ 0 z O-C Z w a ;3,4 U's w U- 0 UZ z D to FIGURE 4-5 Runoff/Acre for Graphic Method Table Ruling Table for Circular Channel i Constiaii Data Manni w coamdert 0.010 Depth 0.33 it Diameter 0.33 it RaWM Table Chwinel Slope Discharge (tttit) (f Via) 0.010000 024 0.020000 0.34 0.030000 0.42 0.040000 0.48 0.050000 0.54 0.060000 0.59 0.070000 0.64 0.080000 0.68 0.090000 0.72 0.100000 0.76 Fab 10, am None Fl MAaslor v41c 1235:36 Hammel Mrewda, mG 37 MOOOM d. Road. WWFbWY. CT OFM tam 7581686 Paae, of t t.P Table Rating Table for Triangular Channel Prefect Description 5.72 Project Fie c -XJhrA FdmfRV.w worksheet Mirsafavt V -Ditch Hy&auics Flow Element Trianoaar Channei Method Manna t FomWa Solve For Discharge Coat Oda Manlings Coellicient 0.013 Depth 1.00 it Left Side Slope 1.00 M: V Fwd Side Slope 1.00 H: V Reting Table Channel slope Discharge (f 1110 (frig) 0.010000 5.72 0.020000 8.08 0.030000 8.90 0.040000 11.43 0.050OW 12.78 0.060000 14.00 0.070000 15.12 0.060000 16.16 0.090000 17.15 0.100000 18.07 Feb 10, 2006 Now 77:51X47 HWMWMdhods,eio. 378roolmWORoad V4d%dx y,CTOBM (7M755 -IMB FteWMnter vtlo Peas t of t 10 Exlsfng Rectangular Channel Worksheet for Rectangular Channel Pry Description Project File c lfmvAn*safav fYn2 Worksheet Mksa" Residence Hydras" 2 Flow Elemer& Re r char w - Ex t srwcv Mettrod Mwwft's Formula Solve For Discharge Input Data MaM*W Coefkkwd 0.013 charnel Slope 0.010000 f" Depth 0.50 It Bottomttyicth 1.00 ft Results Drsdrarge 227 MIS Fk w Area 0.50 fP Wetted Perlmetw 2.00 ft Top WkrIh 1.00 ft Critical Depth 0.54 ft Cry Stops 0.008044 Mft VelocitY 4.54 fus Velocity Heat 0.32 ft Speck Energy 0.82 ft Froude Number 1.13 Flow is superaiticel. Feb 10, BM Nome FWAtoW v ktc 12JOxa0 Hessrea Ms&w s: hn 37 BimdMMa Rosa: watubW. crosaaa (ZM 79 -lees reW 1 w r 1f- MIRSAFAVI RESIDENCE PROPOSED RECTANGULAR Worksheet for Rectangular Channel Worksheet MIRSAFAVI RESIDENCE PROPOSED RECTANGULAR Flow Element Rectsigular Channel Method Marr767g's Formula Solve For Discharge _ Input Data MNW*W Coefficient 0.013 Charnel Slope 0.010000 R/ft D"M 1.00 It Bottom Width 2.00 It Results Dbdmp 14.40 Refs Flow Area 240 ft' Wetted Perimeter 4.00 It Top Width 2.00 It Critical Depth 1.17 It Critikal Slope 0.006571 tf/ft Vdodty 720 fvs Velocity Head 0.81 It SpecMc EnwW 1.81 ft Froude Number 127 Flow is supercrilical. ft M Mw rmr7a t33005 K%s df k%dwC s. kM 3T BMolmWde Road VA*wbvr. CT 0370B (m0) 78 IOW FbAMstsr r4.to Page t of 1 \i3 17- 00- 1 41 CD t 4 4N f A jT C-4 re 50 I i WV� ))) I i golLolE z AN Iva a ■ 0 Lh cl J LL. U LL. Y. z :3 0 U CL 0 EXHIBIT 7 Topographic Survey 10 a � P� s m s o Z r pTx� -nob E ROSA