HomeMy WebLinkAboutX2018-0445 - MiscM Ocean fronit Certificate of Analysis PLM Asbestos Identification Chrysotile <1 % Total Asbestos <1% 70,0293-003 Bedroom Int Plaster Grey 80% Minerals 3 15% Carbonate 5% Paint Chrysmile <1 % Total Asbestos <1% 700293-004 Roof Roofing Black 60% Tar 4 15% Glass Fibers 10% Minerals -0 Total Asbestos None Detected 700293-005 Roof Roofing Black 60% Tar 5 15% Glass Fibers 10% Minerals 15% Cellulose Total Asbestos None Detected Page 1 of 2 W414 -B99-6900 free-M-143-D99B PAMMIM fax - 114.8" .1188 I ""4'j Pairiotiall,com 1041 S. Placentia Aveme, Fulleitoo, (A 92831 Environmental Laborator .y Servic( Jackson Environmental Report Number: 700293 Revision 2 7545 Irvine Center Dr Suite 200 Project Number: Irvine, CA 92618 Project Name: Project Location: 2038 E Oceanfront Newport Beach, CA Date Collected: Collected By: Date Received: 2/7/2018 Claim Number: Date Analyzed: 2/8/2018 PO Number: Date Reported: 2/12/2018 Number of Samples: 6 Lab/Client ID/Layer Location Material Description Color Composition (%) 700293-001 Living Room Int Plaster Grey 80% Minerals 1 15% Carbonate 5% Paint Chrysotile <1 % Total Asbestos <1% 700293-002 Dining Room Int Plaster Grey 80% Minerals 2 15% Carbonate 5% Paint Chrysotile <1 % Total Asbestos <1% 70,0293-003 Bedroom Int Plaster Grey 80% Minerals 3 15% Carbonate 5% Paint Chrysmile <1 % Total Asbestos <1% 700293-004 Roof Roofing Black 60% Tar 4 15% Glass Fibers 10% Minerals -0 Total Asbestos None Detected 700293-005 Roof Roofing Black 60% Tar 5 15% Glass Fibers 10% Minerals 15% Cellulose Total Asbestos None Detected Page 1 of 2 Certificate of Analysis PLM Asbestos Identification Jackson Environmental 7545 Irvine Center Dr Suite 200 Irvine, CA 92618 Report Number: Project Number: Project Name: Project Location: 700293 Revision 2 2038 E Oceanfront Newport Beach, CA tel -IIA -899-9900 free - 88B -243-099B far - 214.09.1188 PalriatLab.(om 1041 S. pra(estla Avenue, rullerton, (A 92831 Date Collected: Collected By: Date Received: 2/7/2018 Claim Number: Date Analyzed: 2/8/2018 PO Number: Date Reported: 2/12/2018 Number of Samples: 6 Lab/Client ID/Layer Location Material Description Color Composition(%) 700293-006 Roof Roofing Black 60% Tar 6 15% Glass Fibers 10%Minerals 15% Cellulose Total Asbestos None Detected Note: This is an amended report issued on 2/9/2018, and re -issued on 2/12/2018. Project name has been updated. Note: This is an amended report issued on 2/8/2018, and re -issued on 2/9/2018. Project location has been updated. 414 Raul Lanuza - Analyst krr Kwin Legaspi - Approved By Bulk samplers) submitted was (were) analyzed in accordance with the procedure outlined in the US Federal Register 40 CFR 763, Subpart F, Appendix A; EPA -600/R-93/116 (Method for Determination of Asbestos in Building Materials), and EPA -600/M4-82-020 (US EPA Interim Method for the Determination of Asbestos in Bulk Insulation Samples).Samples were analyzed using Calibrated Visual Estimations (CVES); therefore, results may not be reliable for samples of low asbestos concentration levels. Samples of wall systems containing discrete and separable layers are analyzed separately and reported as composite unless specifically requested by the customer to report analytical results for individual layers. This report applies only to the items tested. Results are representative of the samples submitted and may not represent the entire material from which the samples were collected. "None Detected" means that no asbestos was observed in the sample. "<1%° (less than one percent) means that asbestos was observed in the sample but the concentration is below the quantifiable level of 1 %. This report was issued by a NIST/NVLAP (Lab Code 200358-0). and CADOHS- ELAP (Cert. No. 2540) accredited laboratory and may not be reproduced, except in full without the expressed written consent of Patriot Environmental Laboratory Services, Inc. This report may not be used to claim product certification, approval or endorsement by NIST, NVLAP; ELAP or any government agency. O tie© c Ooo eUn: o cG c c a m c ooa e a OG( G OCJ 4 ti0 C. ec Doc o e oo Doti o00 Page 2 of 2 Lab Use Only �w Report Number:.� ' X -MI tel - 714.899.8900 free - 088.743.0998 fax - 714-899.1898 www.patfiotEab.com 1041 S. Placentia Avenue, Fullerton, (A 92831 CHAIN OF CUSTODY II.�� • i Environmental Laboratory Services, Inc. Client: Jackson Environmental Project No.: Contact Person: Michael Jackson Project Name: j 120 Tustin Ave, C-1121, Project Location: 17 3 7_ Mo.dx n L.i Newport Beach, CA 92883 d , Contact Phone: 849-230-9779 Sam les Collected By: Contact Fax: Authorized by: Claim #: PO #: How do you want your report? (Circle) Mail Fax Web E-mail: lecrepoMilligmall.oam Special Instructions: Analysis Requested Turnaround Time (business hours/days) RUSH (4 hours) ❑ I RUSH (8 hours) ❑ 24 Hr j 72 Hr ❑ I Other (specify)E] Notae:4HRTATavtlmbreu Viablerunaleam u uIMS.Y a fummoundm me . Baotsri010ultune ra uiemlNmwn30hr TAT.3ttGGIL-wEraad TCLPmrnJ=vbrArue72hm. Asbestos PCM (fiber count) NIOSH 7400A LJ PLM (bulk asbestos) EPA 60018-93/118 Point Count 400 171 GARB 435 0 Point Count 1000 D .- Gravimetric Reduction (emvmeoic Reduefion Requires Minimum Lahr TAT) E3 Microbiology Funai Non -Viable Air Spore Trap, SOP IVA.I m/2m ❑ Viable (Colony ID & Enumeration) Air ❑ Swab/Bylk ❑ Non -Viable Surface Tape LifVSWab/Bulk, SOP IV.4.3m/4m ❑ Bacteria (samples must be received by the laboratory within 24hre of collection or recuse may lieInvalid) Total Colliform and E. coli -Surfaces, Swabs, and Bulk Solids, Liquids (non -potable, non -wastewater) —Presence /Absence ❑ Chemistry Lead by Flame AA - EPA 3050B77420mod, NIOSH 7082mod: Paint ❑ Air ❑ Dust Wipe ❑ Water (non -potable) ❑ Soils/Solids ❑ Lead Waste Profile (by Flame AA) 1: TTLC Total Threshold by EPA 30SOB mod ❑; 2: $TLCICAL WET Tide 22 CCR Ch17 Article $ App 2 ❑ 3: TCLP EPA 1311 ❑ Note: Pleaseprovide at approx. 200 gramsispprm.% lbi of sample for complete profile. Check here to parknin all test necessary for disposal ❑ Rotometer Calibration ❑ pH testing (soils, misc. solids, & liquids) EPA goa5 ❑ Client Sample Sample a Date Sampled p - Location Sampled Description of Sample (Material type, dimensions, etc) Start Time Stop Time Avg. (LPM) Total Min. Total vol (Fbwx x ID Tot. Lin) e z Q4 I! 14 /aS4,/ aIN,. ra4" I 3 rJeQlrOpuA —' % Sbc� dCo a Relinquished B (Print) Michael Jackson Si Date: Time: L) - Received By: Print G — Z Sign: Date. Time: i : 2,f7 Relinquished B.: (Print) Sign: U Date: Time: Received By: (Print) Sign: Date: Time: Method of Shipment/ Preservation During Shipment: %=con Cmptes: Acceptable v o o ° e - 11ww. Foulu 0 lluluillu u,,,o m, cmaan,pira auunmwu ie.ou udya iur sonW sampica, r Libya car argt+srs, ano mpretnaip ror ieaoin air ager analytical real are reported. Unless customer provides written instructions to extend holding time, samples wililbe disposed ofrin accordance with local, state and federal laws. Page t of v.8.18.2014 r L-Drive/Patriot CoC `c 0 a� ooc o o cu oc ooa ' L Lab Use Only '�J �/�%'�� Report Number: X4043 tel -714-899-8900 free - 880-743-0998 fax -114-1199-7098 www.Patriolte0.com 1041 S. Placentia Avenue, Fullerton, (A 9263} Client Sample ID Sample Type Date Sampled Location Sampled Description of Sample (Material type, dimensions, etc) start Time stop Time Avg. (LPM) Min. lain. Totalvol (Flowx Tot Min) G r5dr Relinquished By: (Print) Si Date: Time: Received By: (Print) sign: Date: 2/-7 / -Time/ Relinquished By: (Print) Sign: Date: Time: Received By: (Print) m a Sign: E, o Date: Time: ie UUM wr an eanlples buomnma is au caps wr sono tmmpi- U,<r nays nor oQwis, ana%mmeamm Tor maa in air aver analytical msuns am reported. Unless customer provides written instructions to endsl poidiji(7 tilfle, Iwar(Iplee W1116a r)Ieppse l of In accordance with local, state and federal laws. Page of a v.S.16.2014 . % o L•Drlve/Patriot COC u 0o aa�u o c oo� oa oao xZ018 ^ 39 Ocean�coniF ACKSON COMPREHENSIVE ASBESTOS SURVEY REPORT FOR 2038 E Oceanfront Newport Beach, CA Prepared for Arnold Builders DATE 2/12/2018 Report # 1802-122-700293 CONDUCTED BY Jackson Environmental 120 Tustin Ave C-1121 Newport Beach, CA 92663 ,949'230-W79` o e TABLE OF CONTENTS INTRODUCTION SECTION I ASBESTOS SURVEY SUMMARY Executive Summary Facility Description Survey Findings SECTION II BUILDING INSPECTION FOR ASBESTOS Bulk Sampling Bulk Sample Analysis Quality Assurance Limitation of Sampling Suspect Asbestos Containing Materials SECTION III LABORATORY REPORTS Asbestos Laboratory Reports INTRODUCTION Jackson Environmental was retained by; Arnold Builders to conduct a COMPREHENSIVE Asbestos Survey for the property located at 2038 E Oceanfront, Newport Beach, CA The purpose of this survey was to identify Asbestos Containing Material (ACBM) in all areas of the building. Work consisted of collecting bulk samples of all materials suspect of containing asbestos. THE REPORT The survey report is divided into three major sections, which provide identification of all suspected ACBM. Section I presents a summary of the Asbestos Survey and a general description of the area inspected. Survey findings are also provided in this section. Section 11 describes the methodology used to perform the survey and includes Jackson Environmental, and our Analytical's quality control procedures. Section III of this report summarizes the locations and materials which were identified as containing asbestos. Results of the bulk samples are included in this section. G SECTION I ASBESTOS SURVEY SUMMARY EXECUTIVE SUMMARY Jackson Environmental was retained by, Arnold Builders to conduct a COMPREHENSIVE Asbestos Survey for the property located, at 2038 E Oceanfront, Newport Beach, CA The sampling was conducted by Michael Jackson an Osha certified asbestos consultant # 04-3635 FACILITY DESCRIPTION The subject property is a single-family ,2 story, wood frame building, set on a foundation. While on-site the Certified Personnel noted the condition of the materials. This is noted in the survey findings below. NOTE: this home had undergone demolition activity before report was conducted. SURVEY FINDINGS The following building materials were identified and assumed as containing asbestos: Buildina Material Location Condition SQ' Approximate Roof Mastic Roof penetrations G 25 Interior Plaster <1% Throughout G 3000 "Please note square footages are approximate estimates only and should not be used as a basis for bidding purposes" RECOMMENDATIONS: All Significantly Damaged and Damaged areas should be repaired or removed as soon as possible to avoid any potential hazards that may result from further disturbance of SCM.— —— — ----- - SECTION II COMPREHENSIVE ASBESTOS INSPECTION BULK SAMPLING Bulk samples of areas containing suspect ACBM were collected. A homogeneous area is defined as surfacing material, thermal insulation, or miscellaneous material that is uniform in color, texture, or date of application. Samples were collected using wet methods; where they are deemed appropriate, to minimize fiber release. Prior to sampling, the location is misted with water from a spray bottle. A sample of the suspect material is then collected using a chisel, core borer, knife, or other appropriate tool. After the sample was collected, the bulk material was placed in a sample bag which was sealed to prevent fiber release or contamination by outside sources. Samples are documented by entering the sample data on a bulk log, including a description of the material, a unique sample number is assigned to each sample and the sample bag was labeled with that number. During the survey, the technician also notes the condition of the material being sampled, its location, condition, and friability. Note: The amended National Emission Standard for Hazardous Air Pollutants (NESHAP), November 20, 1990, included a requirement that when the asbestos content of a bulk sample material is determined using procedures outlined in the Interim Method and the asbestos content is estimated to be less than 10% by method other than Point Counting, the parties legally responsible for a building (owner/operator) may elect to assume the amount to be greater than 1 % and treat the material as a regulated asbestos containing material. If the owner or operator does not want to assume the material is asbestos containing, verification of the amount of asbestos by the Point Counting method may be required. The purpose of this procedure is to minimize false negative analysis, and false positive. Point Counting was included in NESHAP in response to an HEPA study that found unacceptable amounts of false positive and false negative analyses by methods outlined in the Interim Method. Unless otherwise directed, American Analytical will assume that PLM analysis is acceptable for this survey. CLASSIFICATION OF BULK BUILDING MATERIALS "S Significantly Damaged Material with one or more of the following characteristics: The surface is crumbling or blistered over at least one tenth of the surface if the damage is evenly distributed :( one quarter or more if the damage is localized). One tenth (one quarter or more, if localized) of material hanging from the surface, deteriorated, or showing adhesive failure. Water stains, gouges, or mars over at least one tenth of the surface if the damaged is evenly distributed (one quarter or more if the damage is localized). Accumulation of powder, dust, or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. We recommend immediate removal of Significantly Damaged material and clean up of the area by a Licensed Asbestos Abatement Contractor. "D" Damaged Material with the following characteristics: The surface is crumbling, blistered, water -stained, gouged, marred or otherwise abraded over less than one tenth of the surface if the damage is evenly distributed (less than one quarter if the damage is localized). Accumulation of powder, dust, or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. We recommended removal of damaged material and clean up of the area by a Licensed Asbestos Abatement Contractor. "G GOOD Material with no visible damage or deterioration, or showing only very damage or deterioration. We recommended materials identified as in good condition be placed on an Operations and Maintenance Program (O & M). BULK SAMPLE ANALYSIS All bulk samples were analyzed by Patriot Laboratory an NVLAP accredited laboratory. The laboratory accreditations are as follows: NVLAP #200642-0 National Voluntary Laboratory Accreditation Program (Federal) Approximately 10% of the bulk samples were split for quality control purpose. All bulk samples were analyzed by Polarized Light Microscopy (PLM) with dispersion staining in accordance with the EPA Method #600/R-93/116.40 CFR 783.87. The reliable limit of detection for PLM is 1.0%. Where "None Detected" or ND appears in the report, it should be interpreted as meaning that no asbestos was actually observed in the sample. Samples containing, "Trace" level of asbestos indicates a possible contamination and is considered ACBM. NOTE: If a sample contains greater than 1.0% asbestos, it is considered to be a regulated material by Federal Government Standards. Under the California State Education Code, materials containing greater than 0.1 % in asbestos content are considered regulated. QUALITY ASSURANCE Statement of Quality Assurance At Jackson Environmental Quality Assurance is priceless! Jackson Environmental is committed to providing analytical services and data to its clients that are of the highest quality and legally defensible. Quality Assurance (QA) procedures were employed to ensure reliable results for analysis of bulk samples as follows: The laboratory is currently participating in the NVLAP Quality Assurance Program. Quality control is processed on at least 10% of all bulk samples on a daily basis. Laboratory results of samples submitted to the laboratory were within 3% of the original side by side sample. LIMITATION OF SAMPLING OF SUSPECT ASBESTOS CONTAINING MATERIAL Reasonable effort is made by Jackson Environmental 's staff to locate and sample suspect materials. However, for any facility the existence of unique or concealed asbestos containing material and debris is a possibility. In addition, sampling and laboratory analysis constraints typically hinder the investigation. American Analytical does not warrant, guarantee or profess to have the ability to locate or identify all asbestos containing materials in any given facility. This report is intended to be used in planning for construction or demolition. This report is not intended to be a construction document. Jackson Environmental is not, and has no responsibility as, a generator, operator, treater, storer, transporter or disposer of hazardous materials or waste found or identified as a result of Jackson Environmental's work. STATE REQUIREMENTS In accordance with State of California Regulation, all surveys are conducted by personnel holding a minimum of a Site Surveillance Technician certificate. This certificate is awarded to individuals who have fulfilled specific educational and experience requirements, as well as having completed extensive training in asbestos specific courses. Additionally, the State also mandates these individuals pass a rigorous examination. This examination is prepared, proctored, and graded by State officials. The Certified Asbestos Consultant must fulfill all the education and experience requirements as the Site Surveillance Technician, but must have additional and more extensive asbestos related training. Candidates for Certified Asbestos Consultant must also pass a more rigorous examination before being approved by the State of California. In compliance with State of California Requirements surveys and reports prepared by a Certified Site Surveillance Technician are reviewed, approved and signed by a Certified Asbestos Consultant. Certified Asbestos Consultant Report # 1802-122-700293 Michael Jackson Project Manager CAC # 04-3635 949-230-9779 �E. SECTION III BULK SAMPLE ANALYSIS