Loading...
HomeMy WebLinkAboutX2019-2507 - MiscX20tq-2507 457 Newrl Censer ®r 5.GetVED aY City of Newport Beach Special Inspector Manual COMMUNITY _ DEVELOPMENT " MAY 13 2019 CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT ` BUILDING DIVISION CITY OF G� 'r,,, � 100 Civic Center Drive IPO Box 1768 1 Newport Beach, CA 92658 ,yFWP exp __ i; vt;orfho-h_a ur_v 1 (949) 644-3200 Of2T SPECIAL INSPECTION REPORT Project Address: 953 Newport Center Drive Permit Number: X2019-0036 /q,-D0y27-C-14 Inspection Type (s): Epoxy Inspection Date (s):_5-1-19 ( ) Periodic. (X) Continuous Describe Inspection, Including Lawtion s : 1. Inspected embedment procedures to install ASTM A-615 gr.60 #4 rebar dowels using Simpson SET -XP epoxy adhesive (exp.9/30/20) @ slab on grade per detail 12/S1.1, at 16" o.c. at line 5.3 slab pourback. List Tests Made: Visual for size, depth, cleanliness of drilled holes and epoxy type/ exp. Total Inspection Time Each Day: Date: 5-1-19 Homs: I 4 Ii Comments: To the best of m knowledge, the work inspected was in accordance with (lie. Building Division approved design drawings, specifications and applicable workmanship provisions of the U.D.C. except as noted above. ci actor gnature: Date: 5-1-19 Print Full Name: Newport Beach Registration No.: David K. Archuleta NB -0690 w•�i.���,wRwo�soo,� oa.vmu 67 City of Newport Beach Special Inspector Manual CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658 nva;� nev:oorlb"'i. iv .:i.an,r 1 (949) 644-3200 SPECIAL INSPECTION REPORT Project Address: 953 Newport Center Drive Permit Number: X2019-0036 Inspection Type (s): Epoxy Inspection Date (s): 5-3-19 ( ) Periodic (X1 Continuous 11. Inspected embedment procedures to install ASTM A-615 gr.60 #4 rebar dowels Ca) 16"o.c. at s.o.a. Cal left storefront & atv.35 ea. utilitv pothole Dourbacks Der List Tests Made: Visual for size, depth, cleanliness of drilled holes and epoxy type/ exp. Total Inspection Time Each Day: Date: 5-3-19 Hours: 4 j ust All Items Requiring correction Include Prevlomly Listed uncorrected Items): None Comments: To the best of my knowledge, the work inspected was in accordance with the Building Division approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. ci ector ignature: Date: 5-3-19 Print Full Name: Newport Beach Registration No.: David K. Archuleta NB -0690 67 ---••_,•••^•- ^� �+�.�:.aw.,wca.macmmsa�nmavaw.wa,+Farmaaur: y;! Pro,'ect Name: Pm'wNo: i Coves p�u O(Z dI Date- I-2Er] It D. yc 1 ocariop; Am ^ Day:. '. T L ��/j ClienUConhsat r. M T W T 4 s S. k c— SuptTommmi: Weather. s u� Field supervigor. �t'^�' ac cv, G�-2.✓ ccw 'J Geologist. 'zx i r r�°i �;� r •%Y.� � �.-�_—�" Engineer: ��^41� . i it �;�� Obeavgp(on/T tin oP/ ir'ti i L Yrs FS%irS 3. ° rl fv GV"�PGU�{%09 Tech 1 Hours N ! E Equipment Working: 12 Summary of Operations: ✓ vow. v, w't rte i C,it t lam. ti- G s N a Page ` of Received by: FIELD REPORT NMG NMG GEOTECHNICAL, INC. Project Name: TG P T Com uwe✓o_c7e Project Na -G Date: - 11 20(i do –4— ` �1 l„/t' QienUContmet L 4 Afu 6or. ,j A�--- �UForeman:t'� 6(� `l'v� % nmk Day: M (OW T F S S Weather: Field Su s r. `Zlni -6 Geologist:' Engineer:� 7 Obs /aati�owTc`sting�o^f /l :7(o b 7u� '.. J Tech Hours Equipment Working W r i Summary of Operations: 5 . l;p �'�✓\ o V at t r4 '.i152 Page off FIELD REPORT Received by NMG NMG GEOTECHNICAL, INC. m �Y i Project N C Prjj�0.6 Z d I G-'�'ZOIry No. tp� 3, .. • ^' LRP � o vl yo Lutetium II nn -T% L.-. M W T. F S S ClienUCon r: Su UFor ae L Field Sup��eii-- n ".. II`-`FtS1'�CJo�,LC eVThe✓ 7�uy leEmcWa (- Tech Obsery I (Geologi/s1t.��� CVotlna� Homa l,a r Equipment Working: - Summary of Operations: vtS I %}v✓. ce... ✓-eS�.. 6 t7 r2.,✓�pp vo✓ co)�iv'Jar.� Lj Nf 1 wet�j s�c� lr ` o in(( ++ o \' r b; c ;i Page of T Received by: FIELD REPORT NMG NMG GEOTECHNICAL, INC, City of Newport Beach Special Inspector Manual CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92656 fill"", rtoJ'r4r al ct a moll 1 (949) 644-3200 SPECIAL INSPECTION REPORT ,�ksCEIVEp 9) - DEVELOPMENT JUL 2 2 2019 CITY OF '%PORT BEPC-`ls Project Address: 953 Newport Center Drive Permit Number: X2019-0036 Inspection Type (s): Reinforced Concrete Inspection Date (s): 6-20-19 ( ) Periodic (X) Continuous Describe Inspection, IncludingLocation(s): 1. Inspected placement of approx. 20 d3 of ASTM C-94 Concrete per Bender Ready Mix #450038 4500 psi, 3/8" agg., 5" slum at slab on grade at service ram . A) Performed water control and sampling of concrete for compressive strength testing. To the best of my knowledge, the work inspected was in accordance will, the Building Division approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. MCI actor gnature: Date: 6-20-19 Print Full Name: Newport Beach Registration No.: David K. Archuleta NB -0690 67 City of Newport Beach Special Inspector Manual CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658 11 n soo�ti� a 11;-)ary I (949) 644-3200 SPECIAL INSPECTION REPORT RgCEIVEO 9y COMMUNITY DEVELOPMENT JUL 2 2 2019 CITYOF �4�VpORT BEPC� Project Address: 953 Newport Center Drive Permit Number: X2019-0036 Inspection Type (s): Reinforced Concrete Inspection Date (s): 6-25-19 ( ) Periodic (X) Continuous Describe Inspection, IncludingLocation(s): 1. Inspected placement of approx. 50 d3 of ASTM C-94 Concreteper Bender Rea #450038 4500 psi, 3/8" agg., 5" slum at slab on grade at grid lines 19-21 between lines A -A.5 & lines 19-22 btwn. lines A.5 -B. A Performed water control & samplina of concrete for compressive strength testin . David K. Archuleta List Tests Made: slump, temperature. Total InsETction Time Each Day: Date: 6-25-19 Houns: 4 Ust NI Items Requiring Correction include Previously Listed Uncorrected Items): Comments: To the best of my knowledge, the work inspected was in accordance with the Building Division approved design drawings, specifications and applicable workmanship provisions of the U.D.C. except as noted above. N ector ignature: Date: 6-25-19 Print Full Name: Newport Beach Registration No.: David K. Archuleta NB -0690 sp<uaumpeaonFepon OU25/2015 67 y Mix STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM OR LIGHTING CONTROL SYSTEM CEC-NRCI-LTI-02-E (Revised 01/16) rat iFnrzwc rnicery rnWA(gsinni CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System (Page 1 of 6) Project Name: r 1 QI� Age11ncyn: / Op �.w, N•3 Enf�rc�-e 1D..lt-� X'�� '2507 X Zo 1 q - Z I7 � Project Addmss:arS3 ry POQ.•r Ce* 1 Ai— D 1� • )ment City ryCW g Dl.+r1V�Y(1 �.Tf- "co i 66 0 GENERAL INFORMATION Enter the date of approval by enforcement agency of the Certificate of Compliance that provides 557 Newpqrl DATE OF BUILDING PERMIT PERMIT# X 2,v l Q 29'7v X'�� '2507 BUILDING TYPE A Nonresidential ❑ High -Rise Res (Common Area) ❑ Hotel/Motel (Common Area) PHASE OF CONSTRUCTION ❑ New Construction ❑ Addition A Alteration ❑ Unconditioned SCOPE OF RESPONSIBILITY Enter the date of approval by enforcement agency of the Certificate of Compliance that provides Date: the specifications for the energy efficiency measures for the scope of responsibility for this Installation Certificate. Requirements in the Standards: §130.4(b) Before an Energy Management Control System (EMCS), or Lighting Control System can be recognized for compliance with the lighting control requirements in Part 6 of Title 24, the person who is eligible under Division 3 of the Business and Professions Code to accept responsibility for the construction or installation of features, materials, components, or manufactured devices shall sign and submit this Installation Certificate. If any of the requirements in this Installation Certificate fail the Energy Management Control System or Lighting Control System installation requirements, these options for controlling lighting shall not be recognized for compliance with the Building Energy Efficiency Standards. Check all that apply: PART 1 What type of Lighting Control System has been installed? ❑ A. Energy Management Control System (EMCS) - Is a computerized control system designed to regulate the energy consumption of a building by controlling the operation of energy consuming systems, such as the heating, ventilation and air conditioning (HVAC), lighting, and water heating systems, and is capable of monitoring environmental and system loads, and adjusting HVAC operations in order to optimize energy usage and respond to demand response signals. ❑ The Energy Management Control System has been installed to function as a lighting control required by Part 6 and functionally meets all applicable requirements for each application for which it is installed, in accordance with Sections 110.9, 130.0 through 130.5, 140.6 through 150.0, and 150.2; and complies with Reference Nonresidential Appendix NA7.7.2. ❑ The EMCS has been separately tested for each respective lighting control system for which it is installed to function as. ❑ B. Lighting Control System -Requires two or more components to be installed in the building to provide all of the functionality required to make up a fully functional and compliant lighting control. ❑ The installed Lighting Control System complies with the requirements checked below; and all components of the system considered together as installed meet all applicable requirements for the application for which they are installed as required in Sections 130.0 through 130.5, Sections 140.6 through 140.8, Section 141.0, and Section 150.0(k). CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM OR LIGHTING CONTROL SYSTEM CEC-NRCI-LTI-02-E Revised 01/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System (Page 2 of 6) ProjeR Name: ( /Jr 1,J�,1 Enforcement Agency: CI(, Irl eF �� Permit Number jp ,f Project A11111Ac,y N "?d Crt &VMTw.A )1Z. City: ErW ODiLT- 3 PART 2 Lighting Control Functional requirements: Check all that apply when verifying the installation of an EMCS or Lighting Control System. ❑ A. All lighting controls and equipment have been installed in accordance with the manufacturer's instructions. ❑ B. The manufacturer has provided instructions for calibration. ❑ C. If indicator lights are integral to any components, such indicator lights consumes no more than 1 watt of power per indicator light. ❑ D. Components that are regulated by the Title 20 Appliance Efficiency Regulations have been certified to the Energy Commission. ❑ E. The EMCS or Lighting Control System functions as one or more of the Time -Switch Lighting Controls checked below, and complies with all of the following requirements: ❑ 1. Automatic Time -Switch Controls meeting all requirements for Automatic Time Switch Control devices in the Title 20 Appliance Efficiency Regulations, including the requirements below: a. Residential automatic time -switch controls have program backup capabilities that prevent the loss of the device's schedule for at least 7 days, and the device's date and time for at least 72 hours if power is interrupted. b. Commercial automatic time -switch controls meet the following requirements: I. Has program backup capabilities that prevent the loss of the device's schedule for at least 7 days, and the device's date and time for at least 72 hours if power is interrupted; ii. Is capable of providing manual override to each connected load and shall resume normally scheduled operation after manual override is initiated within 2 hours for each connected load; and iii. Incorporates an automatic holiday shutoff feature that turns off all connected loads for at least 24 hours and then resumes normally scheduled operation. © 2. Astronomical Time -Switch Controls meeting all requirements for Astronomical Time -Switch Control devices in the Title 20 Appliance Efficiency Regulations, including the requirements below: a. Meets the requirements of an automatic time -switch control; b. Has sunrise and sunset prediction accuracy within plus -or -minus 15 minutes and timekeeping accuracy within 5 minutes per year; c. Is capable of displaying date, current time, sunrise time, sunset time, and switching times for each step during programming; d. Has an automatic daylight savings time adjustment; and e. Has the ability to independently offset the on and off for each channel by at least 99 minutes before and after sunrise or sunset. ❑ 3. Multi -Level Astronomical Time -Switch Controls, in addition to meeting all of the requirements for Astronomical Time -Switch Controls, includes at least 2 separately programmable steps per zone. ❑ F. The EMCS or Lighting Control System functions as one or more of the Daylighting Controls listed below: CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM OR LIGHTING CONTROL SYSTEM CEC-NRCI-LTI-02-E (Revised 01/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System (Page 3 of 6) Project Na..: f i Ct S3 Enforcement Agenry: G' �F 1 s, P�fm_N��^ , —Project nda.e::a S3i0 LW faa.T eeu�rt .Dk caw NF.J Po&.,T 1j' C'RGl-ilk zL1..a ae: ❑ 1. Automatic Daylight Controls meet all requirements for Automatic Daylight Control devices in the Title 20 Appliance Efficiency Regulations, including the following: a. Is capable of reducing the power consumption in response to measured daylight either directly or by sending and receiving signals; b. If the system includes a dimmer, complies with the Dimmer Control device requirements in the Title 20 Appliance Efficiency Regulations. c. Automatically return to its most recent time delay settings within 60 minutes when put in calibration mode; d. Has a set point control that easily distinguishes settings to within 10% of full scale adjustment; e. Has a light sensor that has a linear response within 5% accuracy over the range of illuminance measured by the light sensor; f. Has a light sensor that is physically separated from where the calibration adjustments are made, or is capable of being calibrated in a manner that the person initiating the calibration is remote from the sensor during calibration to avoid influencing calibration accuracy; and g. Complies with the Title 20 requirements for photo controls if the system contains a photo control component. ❑ 2. Photo Controls meet all requirements for Photo Control devices in the Title 20 Appliance Efficiency Regulations, including the following that it does not have a mechanical device that permits disabling of the control. ❑ G. The EMCS or Lighting Control System functions as a Dimmer and meets all requirements for a Dimmer Control device in the Title 20 Appliance Efficiency Regulations, including the following: 1. Is capable of reducing power consumption by a minimum of 65% when the dimmer is at its lowest level; 2. Includes an off position which produces a zero lumen output; and 3. Does not consume more than 1 watt per lighting dimmer switch leg when in the off position. 4. Dimmer controls that can directly control lamps provide electrical outputs to lamps for reduced flicker operation through the dimming range so that the light output has an amplitude modulation of less than 30% for frequencies less than 200 Hz without causing premature lamp failure. 5. If designed for use in three way circuits is capable of turning lights off, and to the level set by the dimmer if the lights are off. ❑ H. The EMCS or Lighting Control System meets the following requirements: 1. Is capable of automatically turning off controlled lights in the area no more than 30 minutes after the area has been vacated; 2. Allows all lights to be manually turned off regardless of the status of occupancy; and 3. Has a visible status signal that indicates that the device is operating properly, or that it has failed or malfunctioned. The visible status signal may have an override switch that turns off the signal. 4. All occupant sensing devices that utilize ultrasonic radiation for detection of occupants meet the Ultrasound Maximum Decibel Values in the Title 20 Appliance Efficiency Regulations 5. All occupant sensing devices that utilize microwave radiation for detection of occupants meet the radiation requirements in the Title 20 Appliance Efficiency Regulations 6. Occupant sensing devices incorporating dimming comply with the requirements for dimmer controls in the Title 20 Appliance Efficiency Regulations CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM OR LIGHTING CONTROL SYSTEM CEC-NRCI-LTI-02-E (Revised 01116) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System (Page 4 of 6) ProjeetName: Enforcement agency: Pe"t Nu a 53 C I 'nf .9F A)- B. 2D/ er:25 Prolec[AddressA 53 Need PaLL-r Ce'►JTL'9!. p 2, 41" MEV Po LT I E—Por- i+ 219CO5 b '0 7. The EMCS or Lighting Control System functions as one or more of the Occupant Sensing Controls Checked Below: ❑ a. Occupant Sensors meeting all applicable requirements for Occupant Sensor Control devices in the Title 20 Appliance Efficiency Regulations. ❑ b. Motion Sensors meeting all applicable requirements for Motion Sensor Controls devices in the Title 20 Appliance Efficiency Regulations, including that motion sensors are rated for outdoor use. ❑ c. Vacancy Sensors meeting all applicable requirements for Vacancy Sensor Controls devices in the Title 20 Appliance Efficiency Regulations, including the following: i. Does not turn on lighting automatically and does not incorporate DIP switches, or other manual means, for conversion between manual and automatic functionality; ii. Has a grace period of no more than 30 seconds and no less than 15 seconds to turn on lighting automatically after the sensor has timed out; and iii. Does not have an override switch that disables the sensor. ❑ d. Partial -ON Sensors meeting all applicable requirements for partial on sensing devices in the Title 20 Appliance Efficiency Regulations, including the following: i. Has two poles each with automatic -off functionality; ii. Has one pole that is manual -on and does not incorporate DIP switches, or other manual means, for conversion between manual and automatic functionality; and iii. Has one pole that is automatic -on and is not be capable of conversion by the user to manual -on functionality. ❑ e. Partial -OFF Sensors meet all applicable requirements for partial off sensing devices in the Title 20 Appliance Efficiency Regulations, including the following: I. Has two poles; ii. Has one pole that is manual -on and manual off; and iii. Has one pole that is automatic -on and automatic -off and is not capable of conversion by the user to manual -on only functionality. ❑ f. Occupant Sensing Control systems consist of a combination of single or multi-level Occupant, Motion, or Vacancy Sensor Controls, and all components installed to comply with manual -on requirements are not capable of conversion by the user from manual -on to automatic -on functionality. CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM OR LIGHTING CONTROL SYSTEM CEC-NRCI-1_TI-02-E (Revised 01/1e) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System (Page 5 of 6) Pmject Name: 10 1 Enforcement Agency: Gelµ/ r ria / T D er�ItNu7 mi� Proiect Addres s t1 dam.' G R- it,: jerw Oaf .O r ftr 1 2iP deZ LA a PART 3 Requirements for which the control is being installed to complied with: Identify all requirements in the Standards for which the EMCS or Lighting Control System is installed to function as and complies with: Check all that are applicable ❑ A. Section 130.1(a) Area Controls. ❑ B. Section 130.1(b) Multi -Level Lighting Controls ❑ C. Section 130.1 (c) Shut -OFF Controls ❑ D. Section 130.1(d) Automatic Daylighting Controls. ❑ E. Section 130.1(e) Demand Responsive Controls. ❑ F. Section 130.5 (d) Circuit Controls for 120 -Volt Receptacles. If installed to qualify for a Power Adjustment Factor, submit this Installation Certificate in addition to the PAF Installation Certificate. ❑ G. To qualify for the PAF for a Partial -ON Occupant Sensing Control in TABLE 140.6-A. ❑ H. To qualify for the PAF for an occupant sensing control controlling the general lighting in large open plan office areas above workstations, in accordance with TABLE 140.6-A ❑ I. To qualify for the PAF for a Manual Dimming System PAF or a Multiscene Programmable Dimming System PAF in TABLE 140.6-A ❑ 1. To qualify for the PAF for a Demand Responsive Control in TABLE 140.6-A ❑ K. To qualify for the PAF for Combined Manual Dimming plus Partial -ON Occupant Sensing Control in TABLE 140.6-A CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 M STATE OF CALIFORNIA ENERGY MANAGEMENT CONTROL SYSTEM OR LIGHTING, CONTROL SYSTEM CEC-NRCI-LTI-02-E Revised 01/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-02-E Energy Management Control System or Lighting Control System (Page 6 of 6) Project Ny¢f`� Enforcement Agency: �I" op ergiNu� e _1 Project Address: q45� NeWPMT e, er Q• •'1 city: .r o21.r' � � 1_f 1• �T zip ¢ 2 6 60 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Installation documentation is accurate and complete. Documg�tatlon Author Name: Docume r re: N0. n '6611 Documentation Author Company Name: I f Date Signed: DVG2o5 �cfXau* t LorITLA�TWtr �1�L1 Ad ress:CEA Certifica on lde tification Qfapplicable): o E. IM}'BR fA� VWy .0l • .5 2_0 city/�atp/dam 9 Z g 2 Phone: 7 f y• b 8 9- 7 000 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conformsto the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 reviewed a copy of the Certificate of Compliance approved bythe enforcement agencythat identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. S. I will ensure that a completed signed copy of this Certificate of Installation shall be posted, or made available with the building permits) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible B der/Installer Name: Responsible Builder/Installer re: wNti.M'L 4S company Name: (Installing Subcontractor or GeneralCo tractor or Builder/Owner) QV G2o.S'G IUI'L Qt'AI% Position With Company(Title): erGwL4✓�. AddM0 8. 100MIA'L &I WW • 5'20 CSLB License Io • 7rof Q City/State/Zip: 2� e -A- 6)28 2) Phone r • 688 • 7000 Date Signed: CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA LIGHTING CONTROL ACCEPTANCE DOCUMENT CEC-NRCA-LTI-02-A IRemsee wn7r CALIFORNIA ENERGY COMMISSION g O NLCAA r�ouo,�.,i u9.1 A cono-anorz o CERTIFICATE OF ACCEPTANCE - NRCA-LTI-02-A Lighting Control Acceptance Document Project Name: F.I. LL IMPROVEMENTS #953 Enforcement Agency: CITY OF NEWPORT BEACH Permit Number: X2019-2970 Project Address: 953 NEWPORT CENTER DRIVE City: NEWPORT BEACH Zip Code: 92660 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Acceptance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ' Gary Ducros Documentation Author Company Name: Dale Signed: November 14 2019 Ducros Electrical Contracting & Design Inc. Address: 2500 E. Imperial Hwy. 201-520 CEA/ATT Certification Identification (If applicable): ATT -1706-00001 City/State/Zip: Brea, CA 92821 Phone: 714-688-7000 FIELD TECHNICIAN'S DECLARATION STATEMENT 1 certify the fallowing under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Acceptance is true and correct. 2. 1 am the person who performed the acceptance verification reported on this Certificate of Acceptance (Field Technician). 3. The construction or installation identified on this Certificate of Acceptance complies with the applicable acceptance requirements indicated in the plans and specifications approved by the enforcement agency, and conforms to the applicable acceptance requirements and procedures specified in Reference Nonresidential Appendix NAT 4. 1 have confirmed that the Certificate(s) of Installation for the construction or installation identified on this Certificate of Acceptance has been completed and signed by the responsible builderfinstaller and has been posted or made available with the building permit(s) issued for the building. Field Technician Name: Field Technician Signature Gary Ducros / Q ct 7 — Field Technician Company Name: Position with Company (Title): Ducros Electrical Contracting & Design Inc. Acceptance Test Technician Address: 2500 E. Imperial Hwy. 201-520 ATT Certification Identification (if applicable): ATT -1706-00001 City/State/Zip: Brea, CA 92821 Phone: 714-688-7000 Date Signed: November 14 2019 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am the Field Technician, or the Field Technician is acting on my behalf as my employee or my agent and I have reviewed the information provided on this Certificate of Acceptance. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Acceptance and attest to the declarations in this statement (responsible acceptance person). 3. The information provided on this Certificate of Acceptance substantiates that the construction or installation identified on this Certificate of Acceptance complies with the acceptance requirements indicated in the plans and specifications approved by the enforcement agency, and conforms to the applicable acceptance requirements and procedures specified in Reference Nonresidential Appendix NAT 4. 1 have confirmed that the Certificate(s) of Installation for the construction or installation identified on this Certificate of Acceptance has been completed and is posted or made available with the building permit(s) issued for the building. 5. 1 will ensure that a completed, signed copy of this Certificate of Acceptance shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a signed copy of this Certificate of Acceptance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Acceptance Person Name: Responsible Acceptance Person Signalc�� _ Gary Ducros Responsible Acceptance Person Company Position with Company (Title): Name: Ducros Electrical Contracting & Acceptance Test Employer Design Inc. Page 2 of 2 (Address: 2500 E. Imperial Hwy. 201-520 ICSLB License: C10 #750903 City/State/Zip: Brea, CA 92821 Phone: 714-688-7000 Date Signed: November 14 2019 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCI-LTI-01-E (Revised 01/161 CAI IF(1RNIA FNFRr Y rnAAMI.CRIr)N CERTIFICATE OF INSTALLATION NRCI-LTI-01-E Indoor Lighting Fr qS (Page 1 of 2) ProtettName: l q s.3 Entortzmen[Agenq; C/ DF N. $ • �''L(J`"�j Z'r7, pF� P.J.d Address EUI Poor ce)-- � D/�-. `": Ne+�Aoa.T Qj (•� �+P Cod ��bO GENERAL INFORMATION Enter the date of approval by enforcement agency of the Certificate of Compliance that provides DATE OF BUILDING PERMIT: PERMIT Zo -1 -1 q7o BUILDING TYPE Nonresidential ❑ High -Rise Res (Common Area) ❑ Hotel/Motel (Common Area) PHASE OF CONSTRUCTION ❑ New Construction ❑ Addition Alteration ❑ Unconditioned SCOPE OF RESPONSIBILITY Enter the date of approval by enforcement agency of the Certificate of Compliance that provides Date: the specifications for the energy efficiency measures for the scope of responsibility for this L0(_T Installation Certificate. In the table below identify all applicable construction documents that specify the requirements for the scope of responsibility reported by this Installation Certificate (continued). Document Title or Description Applicable Sheets or Pages, Tables, Schedules, etc. Date Approved By the Enforcement Agency L0(_T E turIci ft C.At, ft-" s 3. I CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA INDOOR LIGHTING rPr-NRCI-I T -01-F (Revised D1RR) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF INSTALLATION NRCI-LTI-01-E Indoor Lighting (Page 2 of 2) Project Name: ter �M jarw Enforcement AgenN: G1 DF^ M-13 Permi{ Z /w 2at� 13 pow. . Project Address:q 53 <M: NEw PD,¢..H-V 2'P`/°'` 2hybD DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Installation documentation is accurate and complete. Documenta" nAut ar Name: Documentation Au Signature: 4 0.S Das n&-Zee%�G,/Author anGFt� (,Qt.1 �Q1� A DES( Date Signed: / 'o�cua..,g Addressy 000 e, �I�t rc./r- I /�L & y 20-5-t-0 CEA Certificatio dentific tiodn (if applicable): city/statRe/ti C4n P Z) Phone: Wif8V '11900 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 5. 1 will ensure that a completed signed copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of installation is required to be included with the documentation the builder provides to the building owner at occupancy. ResponsiblB "Itder//irrZler Name: Responsible Builder Insta a azure: 0.hilil4 S Company NaTinst filling§ubcontractor or General Contra orBuild ner) Dv(,2o5 WtYr-- IC1 CDA/ rKTN pLi Position With Com any(Title): lJ. ®ccw.cti— VN E, wl riR It f} L t' w `/ ?D 1 • S2v CSLBucense: C 10 , 75-0.7 0,3 City/state/Zip: (-e-A- eA- 282 Phone '7/4 , 6S%-70Q� Date Signed: CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA SUMMARY SHEET CALIFORNIA ENERGY COMMISSION Project Name: Enforcement Agency: Permit Number: Project Address: City: Zip Code: Project Number: Acceptance Test Employer: Acceptance Test Technician: 0 NRCA-LTI.02-A ❑ NRCA-LTI.03-A ❑ NRCA-LTI.04-A ❑ NRCA-LTI.05-A ❑ NRCA-LTO-02-A Fashion Island #953 City of newport beach X2019-0036 953 newport center drive Newport beach 92660 1912-00028 Gary Ducros - ATE -1704-00002 Gary Ducros - ATT -1706-00001 # FORM BUILDING FLOOR NAME 1 Automatic Time Switch Acceptance Test 953 1 BOH 'Sample untested areas are attached in different document. STATE OF CALIFORNIA LIGHTING CONTROL ACCEPTANCE DOCUMENT CEC-NRCA-LTI-02-A IR.„a.d as»I CALIFORNIA ENERGY COMMISSION ❑, ❑ CERTIFICATE OF ACCEPTANCE - NRCA-LTI-02-A Lighting Control Acceptance Document Project Name: FASHION ISLAND #953 Enforcement Agency: CITY OF NEWPORT BEACH Permit Number: X2019-0036 Project Address: 953 NEWPORT CENTER DRIVE City: NEWPORT BEACH Zip Code: 92660 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Acceptance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Gary Ducros --- Documentation Author Company Name: Date Signed: December 05 2019 Ducros Electrical Contracting & Design Inc. Address: 2500 E. Imperial Hwy. 201-520 CEA/ATT Certification Identification (If applicable): ATT -1706-00001 City/State/Zip: Brea, CA 92821 Phone: 714-688-7000 FIELD TECHNICIAN'S DECLARATION STATEMENT I certify the following under penally of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Acceptance is true and correct. 2. 1 am the person who performed the acceptance verification reported on this Certificate of Acceptance (Field Technician). 3. The construction or installation identified on this Certificate of Acceptance complies with the applicable acceptance requirements Indicated in the plans and specifications approved by the enforcement agency, and conforms to the applicable acceptance requirements and procedures specified in Reference Nonresidential Appendix NA7. 4. 1 have confirmed that the Certificate(s) of Installation for the construction or installation Identified on this Certificate of Acceptance has been completed and signed by the responsible builder/installer and has been posted or made available with the building permit(s) issued for the building. Field Technician Name: Field Technician Signature / y� Gary Ducros (��� •-7 Field Technician Company Name: Position with Company (Title): Ducros Electrical Contracting & Design Inc. Acceptance Test Technician Address: 2500 E. Imperial Hwy. 201-520 ATT Certification Identification (if applicable): ATT -1706.00001 City/State/Zip: Brea, CA 92821 Phone: 714-688-7000 Date Signed: December 05 2019 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am the Field Technician, or the Field Technician is acting on my behalf as my employee or my agent and I have reviewed the information provided on this Certificate of Acceptance. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Acceptance and attest to the declarations In this statement (responsible acceptance person). 3. The information provided on this Certificate of Acceptance substantiates that the construction or installation identified on this Certificate of Acceptance complies with the acceptance requirements indicated in the plans and specifications approved by the enforcement agency, and conforms to the applicable acceptance requirements and procedures specified in Reference Nonresidential Appendix NAT 4. I have confirmed that the Certificate(s) of Installation for the construction or Installation identified on this Certificate of Acceptance has been completed and is posted or made available with the building permit(s) issued for the building. 5. 1 will ensure that a completed, signed copy of this Certificate of Acceptance shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable Inspections. I understand that a signed copy of this Certificate of Acceptance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Acceptance Person Name: Responsible Acceptance Person Signatur _ Gary Ducros Responsible Acceptance Person Company Position with Company (Title): Name: Ducros Electrical Contracting & Acceptance Test Employer Design Inc. Page 2 of 2 Address: 2500 E. Imperial Hwy. 201-520 CSLB License: C10 #750903 City/State/Zip: Brea, CA 92821 Phone: 714-688.7000 Date Signed: December 05 2019 STATE OF CALIFORNIA LIGHTING CONTROL ACCEPTANCE DOCUMENT CEC-NRCA-LTI-02-A (eamsed 04117) CALIFORNIA ENERGY COMMISSION PROJECT NUMBER: 1912-00028 CERTIFICATE OF ACCEPTANCE - NRCA-LTI-02-A Automatic Time Switch Acceptance Test Project Name: FASHION ISLAND #953 Enforcement Agency: CITY OF NEWPORT BEACH Permit Number: X2019-0036 Project. Address: 953 NEWPORT CENTER DRIVE City: NEWPORT BEACH Zip Code: 92660 Building: 953 Floor: 1 Room: BOH Note: Submkane Certigcale ofAcceptanceWasuh system that must demmirme semphimme. Enrenement Agenny Use: checked byMais. A.- Construction Inspection 01 Automatic Time Switch Controls Construction Inspection - confirm for all listed In Section B a. All automatic time switch controls are programmed for (check all): 2 Weekdays 2) Weekend 2 Holidays b. Document for the owner automatic time switch programming (check all): 2 Weekday settings 9 Weekend settings O✓ Holidays settings 2 Set-up settings 2 Preference program settings 0 Verify the correct time and date is properly set in the time switch 2 Verify the battery is installed and energized D Override time limit is no more than 2 hours 0 Occupant Sensors and Automatic Time Switch Controls have been certified to the Energy Commission in accordance with the applicable provision in Section 110.9 of the Standards, and model numbers for all such Controls are listed on the Commission database as Certified Appliance and Control Devices B. Functional Testing of Lighting Controls PASS / FAIL Confirm compliance (Yes/No). I Pass 01. Automatic Time Switch Controls Step 1: Simulate occupied condition a. All lights can be turned on and off by their respective area control switch Yes b. Verify the switch only operates lighting in the ceiling -height partitioned area in which the switch is located Yes Step 2: Simulate unoccupied condition a. All lighting, including emergency and egress lighting, turns off. Exempt lighting may remain on per Section 130.1(c)1 and 130.1(a)l Yes b. Manual override switch controls only lights in the selected ceiling height partitioned space where the override switch is located and the lights remain on no longer than 2 hours (unless serving public areas and override switch Is captive key type). Yes Step 3: System returned to Initial operating conditions Yes C. Testing Results PASS / FAIL 1 Automatic Time Switch Controls (all answers must be Y). I Pass D. Evaluation Pass PASS: All applicable Construction Inspection responses are complete and all applicable Equipment Testing Requirements responses are positive (Y -yes). Page 1 of 2 TO: Therma Air 2390 Bateman Ave. Irwindale, ca 91010 Attention: Norm Oda Subject: Final Report )1201q-9507 g571UCwporf Cep �erOr CERTIFIED AIR BALANCE CO. 9970 Bell Ranch Or1w 4101C,S.L 1W5T3 ,�� � QSfi:v941-1200 s.'�. . m. Phone. y 0. Sunk Fc Spnngk CA 9P6111 i3' Pux; J562) 941-1SI10 �Cy' yUti TRANSMITTAL COVER SHEET Date: November 18, 2019 Reference: 19307 Job Name: Fashion Island 953 Newport Center Drive Newport Beach, CA 92660 WE ARE SUBMITTING 1 COPY HEREWITH: ❑✓ Test & Balance Report ❑ Submittal Data ❑ Pre Read Report ❑ Specifications ❑ Post Read Report ❑ Guarantee ❑ Drawings ❑✓ Submitted for approval IMMEDIATE ACTION REQUIRED: ❑ For your approval and return to CABCO ❑ For your proposal ❑✓ For your records ❑ Revision proposals ❑ For your further action ❑ Per your request REMARKS: Very truly yours, CERTIFIED AIR BALANCE CO., INC. By Alexander Torres c�r,�TIFIED AIR BALANCE co. 4970 MI Koch Ilmr 4101 Bantu Fc spf ft& 0.190670 p�,... C,&L 700571 I, PWN-!(%N )4aI-1"INI Fax: (562)9414800 HVAC TEST AND BALANCE ANALYSIS REPORT FOR Fashion Island 953 Newport Center Drive Newport Beach, CA 92660 Contractor: .................. ................... Project Mgr: ...................................... Architect: .......................................... Mechanical Engineer: ....................... ....................................... Therma Air ......................................... Norm Oda .................................... Steiner Studio ....................................... Linwood CERTIFICATION: The data presented in this report is a record of system measurements and final adjustments that have been obtained in accordance with the current edition of the NEBB Procedural Standard for Testing, Adjusting and Balancing of Environmental Systems. The Measurements shown and the information given, in this report are certified to be accurate and complete, at the time and date information was gathered. Any variances from design quantities, which exceed NEBB tolerances, are noted in the TAB report project summary. JobNumber: ...................................................... ... ........ 19307 Date: .................. ........................................ November 18, 2019 Technician: ............................................................ Mark Russell Approved: ................................................. Edward L Santana Jr. iw sM�''�a'CNA' An CERTIFIED AIR BALANCE CO. wkw V4 Spr1rqM C,% WOO TABLE OF CONTENTS Section I Report Abbreviations Section 2 W--, Section 3 Drawings Section 4 Instrument Calibrations Section 5 Certifications CERTIFIED AIR BALANCE CO. 9970 Bell nu nnd.4101 C.&L 70057,1�oos� Fe $mnW Pe Springs, CA 906'10 �otir [9 sou�� Section 1 lltw :(s62Y94I-Ingo FS , (WOO -IMO Report Abbreviations 8 --- sera eo-a x+ai, ss}W io sp.y,., ca sooro Aunx: (asa)sP nz°a CERT/TIED AIR BALANCE CO. REPORT ABBREVIATIONS ACB Active Chilled Beams OBD Opposed Blade Damper ACT Actual OSA Outside Air ACH Air Changes Per Hour PD Pressure Drop AK Free Area Factor PSI Pounds per Square Inch CD Ceiling Diffuser PSID Differential CFM Cubic Feet Per Minute RA Return Air CL Center Line RD Round Diffuser DB Dry Bulb REQ Required DCV Demand Control Ventilation RG Return Grille DD Direct Drive RPM Revolutions Per Minute DN Down SA Supply Air DNA Data Not Available SD Slot Diffuser DNL Data Not Listed SFD Smoke Fire Damper DO Duct Opening SO Screen Opening DT Duct Traverse SP Static Pressure EG Exhaust Grille SR Supply Register ENT Entering SWR Sidewall Register ESP External Static Pressure TDH Total Dead Head FD Floor Diffuser VFD Variable Frequency Drive FPM Feet Per Minute WB Wet Bulb FSD Fire Smoke Damper WG Water Gage FR Floor Registers GPM Gallons Per Minute HD Hood HF HEPA Filters HP Horsepower KH Kitchen Hood LD Linear Diffuser LV Louver LVG Leaving NA Not Applicable / No Access NI Not Installed NM Not Measured NS Not Specified NT Not Tested Due to Abnormal Conditions NVL No Valid Location for Testing CERTIFIED AIR BALANCE CO. 4978 f1G 11 Rw�ch 6r1'�e �+tUl 'p', CSI 7W573 Santa Fe Springy, CA MiCr70 .� yphi Gi 10 V�1� Section 2 TAB Report Phnm�($627411-ty/y00� FJ : (Uct(Ai-7(1,1, Sheet #: Job #: AIR MOVING EQUIPMENT TEST SHEET Proiect: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 19307 SYSTEM ( E ) FCU -A (E) FCU -B Equipment Location — U4711 ami Wancn Onvn 41n,, Swm Fn Sprkw, CA W670 Nnnnn, (6fQ),W—,2d1() CE, R77F[GDAIR BALANCE CO. rm:o6i)�%1.1soo c ¢ 1j: Equipment Manufacturer ,rwsn -Ore-_` CARRIER ;Y Y Date: 11/13/2019 Sheet #: Job #: AIR MOVING EQUIPMENT TEST SHEET Proiect: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 19307 SYSTEM ( E ) FCU -A (E) FCU -B Equipment Location ABOVE CEILING ABOVE CEILING Area Served OPEN SHELL SPACE OPEN SHELL SPACE Equipment Manufacturer CARRIER CARRIER Model L40RMQ008 40RUQAD8T2A6 Serial Number D306XO0694 1516U22715 Motor Sheave & Shaft Size AK44 x 5/8" AK44 x 5/8" Fan Sheave & Shaft Size AK84 x 1" AK84 x 1" Belts/ Shaft A39 (1 OF) 10 1/2" A39 x (1 OF) 10 1/2" Remarks: Specified Actual Specified Actual Total CFM - Fan 3,000 3,007 3,000 3,002 Total CFM - Outlet 3,000 3,007 3,000 3,002 RIA CFM 2,600 2,603 2,400 2,424 O/A CFM 400 404 600 578 Static Pressure (Total / Ext.) 0.50" 0.20" 0.50" 0.19" Inlet Pressure 1760 0.14" 1760 0.13" Discharge Pressure - 0.06" - 0.06" Fan RPM NS 639 NS 637 Motor Sheave & Shaft Size AK44 x 5/8" AK44 x 5/8" Fan Sheave & Shaft Size AK84 x 1" AK84 x 1" Belts/ Shaft A39 (1 OF) 10 1/2" A39 x (1 OF) 10 1/2" Remarks: Specified Actual Specified Actual Motor Manufacturer G.E. MOTOR MARATHON Motor HP NS DNL NS DNL Phase / Frame 3 3 56Y 3 3 56HZ Voltage 460 477 477 1478 460 477 477 j 478 Amperage 2.4 1.8 1.8 1.7 3.3 2.6 2.6 2.5 Motor RPM 1760 1748 1760 1756 Motor Service Factor - 1.15 - 1.15 Motor Sheave Pitch 100% OPEN 100% OPEN Motor Sheave & Shaft Size AK44 x 5/8" AK44 x 5/8" Fan Sheave & Shaft Size AK84 x 1" AK84 x 1" Belts/ Shaft A39 (1 OF) 10 1/2" A39 x (1 OF) 10 1/2" Remarks: , I ROOM NO. • I CODE AK IFACTORI nit/ i��ii J' i1 �4 ACTUAL HTG. MIN. 00/013.0 0". 4101, 8m1. f'n sryi R. CA 00070 Nnnnn' {61i1}!A61 -i11H1 C'LR17FIEDAIR BALANCECO. I CFM rw:{562MAl.i 00 I ACT. SUPPLY AIR SYSTEM Date: 11113/2019 Sheet #: 2 OPEN AREA Unit #: (E )FCU -A SG Job #: 19307 AIR DISTRIBUTION 684 390 Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 ZONE I ROOM NO. I SIZE I CODE AK IFACTORI I REQUIRED ACTUAL HTG. MIN. CFM I FPM I FPM I CFM I REQ. I ACT. SUPPLY AIR SYSTEM (E )FCU -A OPEN AREA 1 14 x 8 SG 0.57 375 657 684 390 OPEN AREA 2 14 x 8 SG 0.57 375 657 625 372 OPEN AREA 3 14 x 8 SG 0.57 375 657 610 365 OPEN AREA 4 14 x 8 SG 0.57 375 657 657 375 OPEN AREA 5 14 x 8 SG 0.57 375 657 657 1 375 OPEN AREA 6 14 x 8 SG 1 0.57 375 657 670 382 OPEN AREA 7 14 x 8 SG 0.57 375 657 659 376 OPEN AREA 8 14 x 8 SG 0.57 375 657 652 372 TOTAL 3,000 3,007 RETURN AIR SYSTEM OPEN AREA 1 22 x 22 SO 3.02 2,600 1 860 861 2,603 TOTAL 2,600 2,603 OUTSIDE AIR SYSTEM OPEN AREA 1 10" DIA DT 0.55 400 727 734 404 TOTAL 400 404 Remarks: 797U Unit f ,,,M U.. 4101, 6.1, 4p Slyly:. CA 91,676 Nhpnp(81M,101-120 CER7IFIED AIR BALANCECO. r":15ea)lW-le60 \42!VDate: 11/13/2019 Sheet #: 3 Unit #: ( E )FCU -B Job #: 19307 AIR DISTRIBUTION Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 ZONE I ROOM NO. I SIZE I CODE I AK FACTORI I REQUIRED ACTUAL I HTG. MIN. CFM I FPM FPM I CFM I REQ. I ACT. SUPPLY AIR SYSTEM (E )FCU -B OPEN AREA 1 14 x 8 SG 0.57 375 657 638 363 OPEN AREA 2 14 x 8 SG 0.57 375 693 395 OPEN AREA 3 14 x 8 SG 0.57 375 649 370 OPEN AREA 4 14 x 8 SG 0.57 375 664 378 OPEN AREA 5 14 x 8 SG 0.57 375 1 651 1 371 OPEN AREA 6 14 x 8 SG 1 0.57 375 665 379 OPEN AREA 7 14 x 8 SG 0.57 375 653 372 OPEN AREA 8 14 x 8 SG 0.57 375 656 374 TOTAL 3,000 3,002 RETURN AIR SYSTEM OPEN AREA 1 38 x 20 SO 4.74 2,400 506 511 2,424 TOTAL 2,400 2,424 OUTSIDE AIR SYSTEM OPEN AREA 1 12" DIA DT 0.78 600 769 741 578 TOTAL 600 578 Remarks: 9'179 Nnll NM"h (Llyn !it0! CERTIFIED AIR BALANCE CO. $Mtn F" SNh9x, CA 90679 Vhnnn' (41;2'�!W'-i Mr r":1882),U1.1606 Date: Sheet #: Job #: AIR MOVING EQUIPMENT TEST SHEET 11/13/2019 Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 19307 SYSTEM (E )FCU -C (E )FCU -D Equipment Location ABOVE CEILING ABOVE CEILING Area Served OPEN SHELL SPACE OPEN SHELL SPACE Equipment Manufacturer CARRIER CARRIER Model 4DRMQ008 40RUQU0842A6 Serial Number 0306XD0693 15161,122858 Motor Sheave & Shaft Size AK44 x 5/8" AK44 x 5/8" Fan Sheave & Shaft Size AK84 x 1" AK84 x 1" Belts / Shaft A39 (1 OF) 10 1/2" A39 ( 1 OF) 10 1/2" Remarks: Specified Actual Specified Actual Total CFM - Fan 3,000 2,996 3,000 2,979 Total CFM - Outlet 3,000 2,996 3,000 2,979 R/A CFM 2,400 2,408 2,400 2,416 O/A CFM 600 588 600 563 Static Pressure (Total I Ext.) 0.50" 0.19" 0.50" 0.18" Inlet Pressure - 0.13" 1,760 0.12" Discharge Pressure - 0.06" - 0.06" Fan RPM NS 634 NS 632 Motor Sheave & Shaft Size AK44 x 5/8" AK44 x 5/8" Fan Sheave & Shaft Size AK84 x 1" AK84 x 1" Belts / Shaft A39 (1 OF) 10 1/2" A39 ( 1 OF) 10 1/2" Remarks: Specified Actual Specified Actual Motor Manufacturer MARATHON MARATHON Motor HP NS DNL NS DNL Phase/Frame 3 3 5 H 3 3 56HZ Voltage 460 477 477 478 460 476 476 i 478 Amperage 1 3.3 2.0 12.0 I 1.9 3.3 1.8 1.8 1.7 Motor RPM 1,760 1,756 1,760 1,754 Motor Service Factor - 1.15 - 1.15 Motor Sheave Pitch 100% OPEN 100% OPEN Motor Sheave & Shaft Size AK44 x 5/8" AK44 x 5/8" Fan Sheave & Shaft Size AK84 x 1" AK84 x 1" Belts / Shaft A39 (1 OF) 10 1/2" A39 ( 1 OF) 10 1/2" Remarks: 7,,4*44\A` ', W9711 Holl K Ctl L +Q 4101, &Mto Fo 8p111:51U. CA 0(16713 Poona' (hQI� 1.451-1200 CERTIFIED AIR BALANCE CO. Pml%2)+A,1800 AIR DISTRIBUTION Date: 11/13/2019 Sheet #: 5 Unit #: (E )FCU -C Job #: 19307 Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 ZONE I ROOM NO. I SIZE I CODE I AK FACTORI I REQUIRED ACTUAL HTG. MIN. CFM I FPM I FPM I CFM REQ. I ACT. SUPPLY AIR SYSTEM ( E )FCU -C OPEN AREA 1 14 x 8 SG 0.57 375 657 650 371 OPEN AREA 2 14 x 8 SG 0.57 375 657 663 378 OPEN AREA 3 14 x 8 SG 0.57 375 657 668 381 OPEN AREA 4 14 x 8 SG 0.57 375 657 642 366 OPEN AREA 5 14 x 8 SG 0.57 375 1 657 645 1 368 OPEN AREA 6 14 x 8 SG 1 0.57 375 657 649 370 OPEN AREA 7 14 x 8 SG 0.57 375 657 652 372 OPEN AREA 8 14 x 8 SG 0.57 375 657 684 390 TOTAL 3,000 2,996 RETURN AIR SYSTEM OPEN AREA 1 44 x 22 SO 6.04 2,400 397 398 2,408 TOTAL 2,400 2,408 OUTSIDE AIR SYSTEM OPEN AREA 1 12" DIA DT 0.78 600 769 753 588 TOTAL 600 588 Remarks: 097n Wil Rm LA n 4101. Smin Fn 8ff"s. CA 90970 Phan' (51M) W I AMP CGR77FIGDAIR BALANCG C'0. r":(sm-wl-+s©n \Q!V Date: Sheet #: Unit #: Job #: AIR DISTRIBUTION 11/13/2019 ( E ) FCU -D 19307 Proiect: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 AIR MOVING EQUIPMENT TEST SHEET Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 SYSTEM (E )FCU -E (E )FCU -F Equipment Location ABOVE CEILING ABOVE CEILING Area Served OPEN SHELL SPACE OPEN SHELL SPACE Equipment Manufacturer CARRIER CARRIER Model 9,r,�"nil �� vwnb,s,.Sma qgm�a..�,ua,u �nr� CGRTIFIGDAIR BALANCE CO. 2715U14693 :(562)461.1600 2,600 2,592 O/A CFM 400 408 400 406 Date: 11/14/2019 0.22" Sheet#: 7 Inlet Pressure Job #: 19307 AIR MOVING EQUIPMENT TEST SHEET Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 SYSTEM (E )FCU -E (E )FCU -F Equipment Location ABOVE CEILING ABOVE CEILING Area Served OPEN SHELL SPACE OPEN SHELL SPACE Equipment Manufacturer CARRIER CARRIER Model 40R00008A2A6 40RUQA08T2A6 Serial Number 2715U14693 1516U22717 Motor Sheave & Shaft Size AK44 x 5/8" AK44 x 5/8" Fan Sheave & Shaft Size AK84 x 1" AK84 x 1' Belts / Shaft A39 (1 OF)10 1/2" A39 (1 OF) 10 1/2" Remarks: Specified Actual Specified Actual Total CFM - Fan 3,000 3,089 3,000 2,998 Total CFM - Outlet 3,000 3,089 3,000 2,998 RIA CFM 2,600 2,681 2,600 2,592 O/A CFM 400 408 400 406 Static Pressure (Total / Ext.) 0.50" 0.22" 0.50" 0.19" Inlet Pressure 1,760 0.14" - 0.13" Discharge Pressure - 0.08" - 0.06" Fan RPM NS 684 NS 635 Motor Sheave & Shaft Size AK44 x 5/8" AK44 x 5/8" Fan Sheave & Shaft Size AK84 x 1" AK84 x 1' Belts / Shaft A39 (1 OF)10 1/2" A39 (1 OF) 10 1/2" Remarks: Specified Actual Specified Actual Motor Manufacturer MARATHON MARATHON Motor HP NS DNL NS DNL Phase/Frame 3 3 56HZ 3 3 56HZ Voltage 460 478 1478 1477 460 4781 478 1 477 Amperage 3.3 2.0 2.0 1.9 3.3 1.8 1.8 1.7 Motor RPM 1,760 1,759 1,760 1,756 Motor Service Factor - 1.15 - 1.15 Motor Sheave Pitch 80% OPEN 100% OPEN Motor Sheave & Shaft Size AK44 x 5/8" AK44 x 5/8" Fan Sheave & Shaft Size AK84 x 1" AK84 x 1' Belts / Shaft A39 (1 OF)10 1/2" A39 (1 OF) 10 1/2" Remarks: Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 ZONE I ROOM NO. I SIZE I CODE AK FACTOR REQUIREDACTUAL HTG. MIN. WITO Boil H d, 04VP bin t, SM10Vn SlvkW, CA 1)(1970 Pnnnn' (��id}!H �•� lAtl CERTIFIED AIR BALANCE CO. I CFM rm: tssx) ,.yew ACT. SUPPLY AIR SYSTEM Date: 11/14/2019 Sheet #: 8 OPEN AREA Unit #: ( E )FCU -E SG Job #: 19307 AIR DISTRIBUTION 668 381 Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 ZONE I ROOM NO. I SIZE I CODE AK FACTOR REQUIREDACTUAL HTG. MIN. CFM FPM I FPM I CFM REQ. ACT. SUPPLY AIR SYSTEM (E )FCU -E OPEN AREA 1 14 x 8 SG 0.57 375 657 668 381 OPEN AREA 2 14 x 8 SG 0.57 375 657 677 386 OPEN AREA 3 14 x 8 SG 0.57 375 657 663 378 OPEN AREA 4 14 x 8 SG 0.57 375 657 686 391 OPEN AREA 5 14 x 8 SG 0.57 375 657 684 390 OPEN AREA 6 14 x 8 SG 1 0.57 375 657 680 388 OPEN AREA 7 14 x 8 SG 0.57 375 657 686 391 OPEN AREA 8 14 x 8 SG 0.57 375 657 673 384 TOTAL 3,000 3,089 RETURN AIR SYSTEM OPEN AREA 1 44 x 22 SO 6.04 2,600 430 444 2,681 TOTAL 2,600 2,681 OUTSIDE AIR SYSTEM OPEN AREA 1 10" DIA DT 0.55 400 727 741 408 TOTAL 400 408 Remarks: 0070 Son 8m US.. 6101.8.1. "EpMgR, CA 110590 Vhow (6Q) -941-12(R CERTIFIED AIR BALANCE CO. ru!: 662)6w.1800 \ZtV Date: Sheet #: AIR DISTRIBUTION 11/14/2019 Unit #: (E )FCU -F Job #: 19307 Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 ZONE I ROOM NO. I SIZE I CODE AK IFACTORI I REQUIRED ACTUAL HTG. MIN. CFM I FPM I FPM I CFM I REQ. I ACT. SUPPLY AIR SYSTEM (E )FCU -F OPEN AREA 1 14 x 8 SG 0.57 375 657 645 368 OPEN AREA 2 14 x 8 SG 0.57 375 657 650 371 OPEN AREA 3 14 x 8 SG 0.57 375 657 661 377 OPEN AREA 4 14 x 8 SG 0.57 375 657 642 366 OPEN AREA 5 14 x 8 SG 0.57 300 526 528 301 OPEN AREA 6 14 x 8 SG 0.57 300 526 535 305 OPEN AREA 7 14 x 8 SG 1 0.57 450 789 792 452 OPEN AREA 8 14 x 8 SG 0.57 450 789 803 458 TOTAL 3,000 2,998 RETURN AIR SYSTEM OPEN AREA 1 44 x 10 SO 2.74 2,600 948 945 2,592 TOTAL 2,600 2,592 OUTSIDE AIR SYSTEM OPEN AREA 1 10" DIA DT 0.55 400 727 738 406 TOTAL 400 406 Remarks: 5 nUfn enil 1 rh L7 n t,01 CERTIFIED AIR BALANCE, CO. las , Sry . Y, SprWWt CA 110970 Phnnn. (Sti2}!M1.1200 Pox! M2)AA,•18W Date: 11/14/2019 Sheet #: 10 Job #: 19307 AIR MOVING EQUIPMENT TEST SHEET Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 SYSTEM (E )FCU -H EF -1 Equipment Location ABOVE CEILING ABOVE CEILING Area Served OPEN SPACE 941 RESTROOM Equipment Manufacturer CARRIER GREENHECK Model FX4CNF04800 SP -80 -VG Serial Number 3107A82416 DNL Motor Sheave & Shaft Size DIRECT DRIVE DIRECT DRIVE Fan Sheave & Shaft Size DIRECT DRIVE DIRECT DRIVE Belts / Shaft I DIRECT DRIVE DIRECT DRIVE Remarks: Specified Actual Specified Actual Total CFM - Fan 1,600 1,615 75 78 Total CFM - Outlet 1,600 1,615 75 78 RIA CFM 1,440 1,451 - - O/A CFM 160 164 - - Static Pressure (Total / Ext.) 0.50" 0.23" 0.50" 0.16" Inlet Pressure - 0.13" SPEED CONTROL 0.06" Discharge Pressure 0.10" 0.10" Fan RPM NS HIGH NS MEDIUM Motor Sheave & Shaft Size DIRECT DRIVE DIRECT DRIVE Fan Sheave & Shaft Size DIRECT DRIVE DIRECT DRIVE Belts / Shaft I DIRECT DRIVE DIRECT DRIVE Remarks: Specified Actual Specified Actual Motor Manufacturer GENTEQ VARIGREEN Motor HP NS 3/4 NS 6 WATTS Phase / Frame 1 1 NA 1 1 NA Voltage 208 - 1210 120 120 1 - Amperage 4.1 12.8 0.3 0.1 1 - Motor RPM NS DIRECT DRIVE SPEED CONTROL SET AT 6.0 Motor Service Factor 1.0 1.0 Motor Sheave Pitch DIRECT DRIVE Motor Sheave & Shaft Size DIRECT DRIVE DIRECT DRIVE Fan Sheave & Shaft Size DIRECT DRIVE DIRECT DRIVE Belts / Shaft I DIRECT DRIVE DIRECT DRIVE Remarks: rv1 nxna'<.o 9977 4011 H ch Ui WO T, $mla f0 $ryivye. Cq',I[IE7[! PnnM' [51{2}!161-,'t11R CERTIFIED AIR BALANCE CO. r.1lus$z�f,.,.,saa Date: 11/14/2019 Sheet #: 11 Unit #: ( E )FCU-H & EF-1 Job #: 19307 AIR DISTRIBUTION Project: Fashion Island - 953 Newport Center Drive, Newport Beach, CA 92660 Remarks: ....... . . .. CERTIFIED AIR BALANCE CO. - --------- - 7&;3�3 t WO EkIl Rawlt Dfll� Owl .1d S=W Fe Spmn6A CA 9D670 Fm: (56-21941-Ifm Section 3 Drawings \`ELE�w + g t ! § \ f y � t d A - e_ ! y § § 9 $ » A » y 6 $ A » G t, f % \ � C)- O =3 ff�-Vs q,\( \ \/� _ . •! \`ELE�w + g t ! § \ f y � t d A - e_ ! y § § 9 $ » A » y 6 $ A » G t, f % \ � C)- O =3 IpJ CERTIFIED AIR BALANCE CO. 9970 Hell R �xh IrNw Viol , �'� G.S.I. 7oQ5?3 � a(562) WI -121W SMU Fe SprinaA CA %670 y ... - y* F.Y= (Wf 941-ING Section 4 Instrument Calibrations FJF CODE No: Model: PLT -5000 Description: Non -Contact Tachometer Serial No: 819385M p Range: 6 to 99,999 RPM Tolerance: t1.0RPM ;6 to 599.9 RPM -+-0.0061/o of reading -0.5 digit 600.0 to 99,999 RPM Date Calibrated: 19 -Mar -2019 Calibrated by: Hao Zhang Conditions Degree Fahrenheit: 70 °F Relative Humidity: 65 %"' This certificate attests that this instrument has been calibrated under the standard conditions with standards traceable to the National Institute of Standards and Technology (NIST). Evidence of traceability is included and also maintained on file at our laboratory. An acceptable accuracy ratio between the standard and the item calibrated has been maintained. Accuracy of standard used for certification is equal to or greater than the accuracy of the certified instrument. Calibration is in conformance with manufacture's specification. Standard Used: CALIBRATOR Model: TACH CAL Serial No: G050485 Accuracy: Certificate of Calibration No. 1118887 Standard Actual Error Tolerance Reading 10 1 AIRDATA MULTIMETER CERTIFICATE OF RECALIBRATION Customer ID: 013264 SIN: M11761 Customer:_ CERTIFIED AIR BALANCE CO. INC- City: SANTA FE SPRINGS State: CA Mo As -Received del #: ADM -880C Converted to Model #:Order #: R192693 PO #: Customer Eqpt ID#:_ Calibration Due Date: 09/2020 has Calibration Technicia Calibration Approved by:_ AS -Received which are traceable to NISI n and calibration procedure is certified when meters an r). This report shall not be it limitations on use, see ssure, Absolute Pressure FWAL L Test Date r^cl IIG I Ambient Temperature --,—-� �1-7 T'F Ambient Temp Barometric Pressured S-_ Hg Barometric Pre All within spec,�S''° NO NA All within spec of use Calibration Date: 0 9Z /'i /act 9 Title: Date —� Test By _ Rh r�A Date—. Rh —% `1-1 °F Ambient TemperetuLe F a i,, in Hg Barometric Pressure_in Hg NO All within spec YES NO ABSOLUTE PRESSURE TEST (in Hg) TEST METER TOLERANCE = t 2.0 % ±.I in Hg AS -RECEIVED TEST WITHIN SPECYES.1 NO N/A See Nates Pressure Standard: Heise #02-R SIN : 41741/42451 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #12A- SIN: 45605/48491 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #04-R SIN: 41743/42453 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #14-R SIN: 43412/45043-1 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #06-R SIN: 41742/42452-1 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #16-R SIN: 43413/45044 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #08-R SIN: 42186/43328 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #18-R SIN: 44581146845 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #10-R S/N: 42203143352 As-Rcvd es(-Pj Test 3 Pressure Standard: Heise #20-R SIN: 44582/46847 �4s,_Rcvd gest 2 Test 3 Approx Set Pt Standard Test Meter % Diff Standard Test Meter % Diff Standard Test Meter % Diff i4.o 1 4S L{t- .r Z r 4 t — ` 28.4 DIFFERENTIAL PRESSURE TEST (in we) - 40.0 .2250 , Z -Z -7q , ZZ 1 p- TEST METER TOLERANCE = t 2.0 % 10.001 in we AS -RECEIVED TEST WITHIN A prox Set Pt Standard Test Meter % Diff Standard Test Meter % Diff Standard Test Meter % Diff 0500 ,(]`i(l.3 c X -'Ur rr)I' 0!0"7 DIFFERENTIAL PRESSURE TEST (in we) .2250 , Z -Z -7q , ZZ 1 p- TEST METER TOLERANCE = t 2.0 % 10.001 in we AS -RECEIVED TEST WITHIN SPECES NO NIA See Notes Pressure Standard: Heise #01-L SIN: 41739/42449 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #11-L SIN: 43165/44551-1 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #01-R SIN: 41739/42446 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #11-R SIN: 43165/44730 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #02-L SIN: 41741/42454 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #12A -L SIN: 45605148490 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #03A -L SIN: 45570/48461 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #13-L SIN: 43415/45041 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #03A -R SIN: 45570148460 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #13-R S/N: 43415145039 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #04-L SIN: 41743/42456 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #14-L SIN: 43412/45045 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #05-L SIN: 41740/42450 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #15-L SIN: 43416145042 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #05-R SIN: 41740142447 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #15-R SIN: 43416/45040 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #06-L SIN: 41742/42455 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #16-L SIN: 43413/45046 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #07-L SIN: 42185/42186 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #17-L SIN: 44579/46842 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #07-R SIN: 42185/43326 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #17-R SIN: 44579/46841 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #08-L SIN: 42186/43329 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #18-L SIN: 44581/46846 As-Rcvd Test 2 Test 3 Pressure Standard: Heise #09-L SIN: 42202/43351 As-Rcvd escvrest 3 Pressure Standard: Heise #19-L SIN' 44580/46844 (A - v Nest 2 Test 3 Pressure Standard: Heise #09-R SIN: 42202/43350 As-Rcvd Test3 Pressure Standard: Heise #19-R SIN: 44580/46843 Test 2 Test 3 Pressure Standard: Heise #10-L SIN: 42203/43353 As-Rcvdesf Test 3 Pressure Standard: Heise #20-L S/N: 44582146848 s-Rcv .%Test 2 Test 3 A prox Set Pt Standard Test Meter % Diff Standard Test Meter % Diff Standard Test Meter % Diff 0500 ,(]`i(l.3 c X -'Ur rr)I' 0!0"7 1250 .2250 , Z -Z -7q , ZZ 1 p- 1.000 i-C,�U I,n,: . —,iq 1 ot1 L011 0 2.000 Z ,1, I Z 2 . G.�r1 -,!5 '1 Q o f ;�' 00 `9 0 - lk 3.600 -�.�T iC .(/-i�� _13c, --�4 trrl3 3. (p0 -33 4.400 (, ti Ll 7 0 Z. LL LI' I Lf L Ll 1 q I I 27,00 C &-I J7 I 50.00 SC. q h .5 C, 4 1 -, i o 50,11 1 IN Overange NA I v% I- -NA - NA INA NA '-' NA ShortridInstruments, Inc. 7855 East Redfielde oad Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com ADM Recalibration Rev47/07/01/19 1 of 2 07101/19 AIRDATA MULTIMETER CERTIFICATE OF RECALIBRATION S/N: M 1 l 1 tv1 Order #:�3- 100 (6 1 1 '' LOW VELOCITY CONFIRMATION (FPM) Test 3 _ ,k 154.4° F 500 ,r i esf2� Test 3 Set Point: 35.6° 95° P 154.4° F TEST METER TOLERANCE = t 3.0% t 7 FPM AS -RECEIVED TEST WITHIN SPEC YES O N/A See Notes Set Point: 35.6° F Vel Eqv Trans Std: SIN: M02009 As-Rcvd Test 2 Test 3 Vel Eqv Trans Std: SIN: Ml 0897 As-Rcvd Test 2 Test 3 Vel Eqv Trans Std: SIN: M02903 As-Rcvd Test 2 Test 3 Vel Eqv Trans Std: SIN: M10901 As-Rcvd (e_ffZ, Test 3 Vel Eqv Trans Std: Sft M10839 As-Rcvd Test 2 Test 3 Vel Eqv Trans Std: SIN: M13492 As-Rcvd Test 2 Test 3 Vel Eqv Trans Std: SIN: Ml 0840 As-Rcvd Test 2 Test 3 Vel Eqv Trans Std: SIN: Ml 9325 A1--A_c_v ;P Test 2 Test 3 n.,..rnv Ccl onlnr Cr'Jr H.'ri T..ea Wnnn Miff cmndarri Tnee LIM- fldn ctru" "l Diff 100 (6 1 1 '' /10 Test 3 _ ,k 154.4° F 500 ,r i esf2� Test 3 Set Point: 35.6° 95° P 154.4° F RTD Simulator SIN 253 ADM -880C, ADM -870/870C and ADM -860/860C models are read in AirFoil Mode. ADM -850/850L models are read in Pitot Tube Mode. TEMPERATURE TEST - AIRDATA MULTIMETER (° F) TEST METER TOLERANCE = t 0.2° F AS -RECEIVED TEST WITHIN SPEC(ES NO N/A See Notes RTD Simulator Temperature Eouivalent Set Point Test Meter Difference Test Meter Difference Test Meter Difference RTD Simulator: SIN 249 AslTcvv7q .' Te_s_t 2J Test 3 Set Poin 35.6° 95° F 154.4° F RTD Simulator: SIN 250 � NS Rcvd esf2� Test 3 Set Point: 35.6° 95° P 154.4° F RTD Simulator SIN 253 (A5-R4Y¢` es? Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 254 As•Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 256 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 257 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 292 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 293 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 294 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 313 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 314 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 315 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 316 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 317 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F RTD Simulator: SIN 318 As-Rcvd Test 2 Test 3 Set Point: 35.6° F 95° F 154.4° F 35.60 3p 3 �. i 95.00 ._:_ C) 154.40 /S y. y (� 4, I The enclosed ADM Calibration Standards for Pressure and Temperature forms) is/are an integral part of this calibration and must remain with this Certificate of Calibration. Note: There may be more than one such form included that pertains to this calibration. Shortrid e Instruments, Inc. 7855 East Redfield cad Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com ADM Recalibration Rev47/07/01/19 2 of 2 07/01/19 Shortridge Instruments, Inc. AirData Multimeter Calibration Equipment Order Number: _r<I 1 % x`13Serial Number: Yn I I �) Test Type: Initial As -Received ( Fin �_ ABSOLUTE PRESSURE STANDARDS ADM #02-R SIN: 41741/42451 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 04/30/19 Due Date: 04/2020 ADM #04-R SIN: 41743/42453 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11/28/18 Due Date: 11/2019 ADM #06-R SIN: 41742/42452-1 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08/21/19 Due Date: 08/2020 ADM 408-R SIN: 42186/43328 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/22/19 Due Date: 03/2020 ADM #10-R SIN. 42203/43352 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 01/21/19 Due Date: 01/2020 ADM #12A -R SIN: 45605/48491 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 07/16/19 Due Date: 07/2020 ADM #14-R SIN : 43412/45043-1 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09/28/18 Due Date: 09/2019 ADM #16-R SIN: 43413/45044 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/20/19 Due Date: 02/2020 ADM #18-R SIN: 44581146845 Heise Model: PPM -2 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date. 05/17/19 Due Date: 05/2020 ADM #20-R SIN: 44582/46847 Heise Model: PPM -2 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 06/20/19 Due Date: 06/2020 #02-R, 04-R, 06-R, 08-R, 10-R, 12A -R, 14-R, 16-R Rated Accuracy: 0.05% is (0.0305 in Hg) Range: 0-30 psia Resolution: 001 Uncertainty: < 0.0358 #18-R, 20-R SIN : Rated Accuracy: 0,05% fs (0.0305 in Hg) Range: 0-60 in Hg Resolution: 0.001 Uncertainty: < 0.0358 DIFFERENTIAL PRESSURE STANDARDS ADM #01-L SIN : 41739142449 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 05/01/19 Due Date: 04/2020 ADM #01-R SIN : 41739/42446 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 05/01/19 Due Dale: 04/2020 ADM #02-L SIN : 41741142454 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 05/01/19 Due Date: 04/2020 ADM #03A -L SIN: 45570/48461 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11/28/18 Due Date: 11/2019 ADM #03A -R SIN : 45570/48460 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: l 1128118 Due Date. 11/2019 ADM #04-L SIN: 41743/42466 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11/28118 Due Date: 11/2019 ADM #05-L SIN: 41740/42450 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08/26/19 Due Date: 08/2020 ADM #05-R S/N'. 41740/42447 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08/28/19 Due Date: 08/2020 ADM #06-L SIN. 41742/42455 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 08/26/19 Due Date: 08/2020 ADM #07-L SIN: 42185/42186 Heise Model: PPM -i Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/26/19 Due Date: 03/2020 ADM #07-R SIN : 42185/43326 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/26/19 Due Date: 03/2020 ADM #08-L SIN : 42186/43329 Heise Model. PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/25/19 Due Date: 0312020 ADM #09-L SIN: 42202/43351 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date. 01/23/19 Due Date: 0112020 ADM #09-R SIN : 42202/43350 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 01/23/19 Due Date: 01/2020 ADM 910-L SIN : 42203/43353 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 01/23/19 Due Date: 01/2020 ADM #11-L SIN : 43165/44551-1 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 07/15/19 Due Date: 07/2020 ADM #11-R SIN. 43165/44730 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 07115/19 Due Date: 07/2020 ADM #12A -L SIN: 45605148490 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 07/16/19 Due Date: 07/2020 ADM #13-L SIN : 43415/45041 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10/03/18 Due Date: 0912019 ADM #13-R SIN : 43415/45039 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10/04/18 Due Date: 09/2019 ADM #14-L SIN : 43412/45045 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10/02/18 Due Date'. 0912019 ADM #15-L SIN: 43416/45042 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/22/19 Due Date: 02(2020 ADM #15-R SIN: 43416/45040 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/22/19 Due Date: 02/2020 ADM #16-L SIN: 43413/45046 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/21/19 Due Date: 0212020 ADM #17-1_ SIN' 44579146842 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 05/16/19 Due Date', 05/2020 ADM #17-R SIN: 44579146841 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Dale: 05/21/19 Due Date'. 05/2020 ADM #18-L SIN: 44581/46846 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date', 05/16/19 Due Date: 05/2020 ADM #19-L SIN: 44580/46844 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07/15/19 Due Date: 06/2020 ADM ii SIN: 44580/46843 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07/15/19 Due Date: 06/2020 ADM #20-1_ SIN: 44582/46848 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 06/18/19 Due Date: 06/2020 #01-L, 03A -L, 05-L, 07-L, 09-L, 1 I -L, 13-L, 15-L, 17-L, 19-L Rated Accuracy: > 0.07% Is (0.000175 in wc) Range: 0.0-0.25 in we Res.: 0.00001 Uncertainty: < 0.00035 #01-R, 03A -R, 05-R, 07-R, 09-R, 11-R, 13-R, 15-R, 17-R, 19-R Rated Accuracy: > 0,06% fs ( 0.003 in wc) Range: 0.0-5.0 in we Res.: 0.0001 Uncertainty'. < 0.00348 #02-L, 04-L, 06-L, 08-L, 10-L, 12A -L, 14-1_, 16-L, 18-L, 20-1_ Rated Accuracy: > 0.06% is 10.03 in we) Range: 0.0-50.0 in we Res.: 0.001 Uncertainty: < 0.0346 Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com ADM Cal Stnds Rev 14109/24118 1 of 2 09/16/19 Shortridge Instruments, Inc. AirData Multimeter Calibration Equipment Customer Order Number, Meter Serial Number, and Test Type are referenced on page 1 LOW VELOCITY EQUIVALENT CONFIRMATION STANDARDS Vol Eqv Transfer Standard SIN: M02009 Model ADM -870C Vel Eqv Transfer Standard SIN: M02903 Model ADM -870C Vel Eqv Transfer Standard SIN: M10839 Model ADM -870C Vel Eqv Transfer Standard SIN: M10840 Model ADM -870C Vel Eqv Transfer Standard SIN'. M10897 Model ADM -870C Vel Eqv Transfer Standard SIN: M10901 Model ADM -870C Vel Eqv Transfer Standard SIN: M13492 Model ADM -870C Vel Eqv Transfer Standard SIN: M19325 Model ADM -870C Rated Accuracy: Velocity± 1.5 % ± 3.5 fpm Mfgd & Calibrated by Shortridge Instruments, Inc. Mfgd & Calibrated by Shortridge Instruments, Inc. Mfgd & Calibrated by Shortridge Instruments, Inc. Mfgd & Calibrated by Shortridge Instruments, Inc. Mfgd & Calibrated by Shortridge Instruments, Inc. Mfg'd & Calibrated by Shortridge Instruments, inc. Mfg'd & Calibrated by Shortridge Instruments, inc. Mfgd & Calibrated by Shortridge Instruments, Inc. Range: 100-5000 fpm Resolution: 0.1 TEMPERATURE STANDARDS Calibration Date: 12/07/18 Due Dale'. 12/2019 Calibration Date: 12/07/18 Due Dale: 12/2019 Calibration Date: 12/07/18 Due Date: 1212019 Calibration Date: 12/07118 Due Date: 1212019 Calibration Date: 01/17/19 Due Date: 0112020 Calibration Date: 12/07/18 Due Date: 1212019 Calibration Date: 08/08/19 Due Date. 08!2020 Calibration Date: 06/21/19 Due Date: 06/2020 Uncertainty: <5.00 fpm at 100 fpm', <7.50 fpm at 500 fpm RTD Simulator SIN: 249 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 03/16/16 Due Date'. 03/2020 RTD Simulator SIN: 250 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 03/16/16 Due Date 03/2020 RTD Simulator SIN: 253 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 03/16/16 Due Date. 03/2020 RTD Simulator S/N'. 254 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date. 04/07/16 Due Date: 04/2020 RTD Simulator SIN: 256 Model RTD -10001500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/07/16 Due Dale: 04/2020 RTD Simulator SIN: 257 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/07/16 Due Date: 04/2020 RTD Simulator SIN: 292 Model RTD -10001500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 12/21/15 Due Date 12/2019 RTD Simulator SIN: 293 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 12/21/15 Due Date: 1212019 RTD Simulator SIN: 294 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 12/21/15 Due Date: 12/2019 RTD Simulator SIN: 313 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: D3/16118 Due Date 03/2022 RTD Simulator SIN: 314 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: D3/16/18 Due Date. 03/2022 RTD Simulator SIN: 315 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 03/16/18 Due Date: 03/2022 RTD Simulator SM: 316 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/16/18 Due Date'. 0412022 RTD Simulator SIN: 317 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/16/18 Due Date: 04/2022 RTD Simulator SIN: 318 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/16/18 Due Dale: 04/2022 Rated Accuracy: 0.025% of setting Range: 100.00 D to 11111.10 n Resolution'. 0.01 D Uncertainty: ; 32 ppm Thermometer #1 SIN 8A089/Thermistor SIN A410660 Model 150415610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date: 08/27/19 Due Date: 0812021 Thermometer #2 SIN BB1041Thermistor S/N 871507 Model 150415610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date: 11/07/18 Due Date'. 10/2020 Thermometer #5 SIN B11780/Thermistor SIN B10505 Model 1504/5510 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date: 03/07/19 Due Date: 0312021 Thermometer #6 SIN B11782/Thermistor SIN 810509 Model 1504/5610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date: 02/20/18 Due Date. 0212020 Thermometer #7 SM 849938/Thermistor S/N B482202 Model 1504/5610 Mfgd and Calibrated by Fluke Calibration Dale: 09/26/17 Due Date 09/2019 Rated Accuracy(combined): 0.0324° F Range: 32' F to 176° F Resolution: 0.001 ° F Combined Uncertainty with Baths. ; 0.040° F Temp Transfer Standard SIN M00136 Model ADM -870 Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date. 10/04/18 Due Date: 10/2019 Temp Transfer Standard SIN M96100 Model ADM -870 Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 03/07/19 Due Date: 03/2020 Rated Accuracy: 0.03° F Range: 33° F to 158° F Resolution. 0.01 ° F Uncertainty. < 0.023- F Total combined Uncertainty for MultiTemp and TemProbe testing : s 0.046° F This form must remain with the Certificate of Calibration corresponding to the Customer Order Number and Meter Serial Number referenced on page 1. Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com ADM Cal Since Rev 14109/24/18 2 of 2 09/16/19 Shortridge Instruments, Inc. AirData Multimeter Calibration Equipment Order Number: �Z\ c'Z 9 3— Serial Number: M I, 1-1 ®� Test Type: Initials'Receiv�- Final ABSOLUTE PRESSURE STANDARDS ADM #02-R SIN: 41741142451 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date. 04/30/19 Due Date 04/2020 ADM #04-R SIN: 41743142453 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11128118 Due Date: 11/2019 ADM #06-R SIN : 41742142452-1 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09/10/18 Due Date: 0812019 ADM #08-R SIN: 42186/43328 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/22119 Due Date* 0312020 ADM #10-R SIN: 42203/43352 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 01/21/19 Due Dale 0112020 ADM #12A -R SIN: 45605/48491 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date'. 07/16/19 Due Date: 07/2020 ADM #14-R SIN. 43412/45043-1 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09/28/18 Due Date: 0912019 ADM #16-R SIN: 43413/45044 Heise Model: PPM -2 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/20/19 Due Date: 0212020 ADM #18-R SIN: 44581/46845 Heise Model: PPM -2 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 05/17/19 Due Date05/2020 AOM #20-R SIN: 44582146847 Heise Model PPM -2 Mfgtl & Calibrated by Ashcroft, Inc. Calibration Date: 06/20/19 Due Date: 06/2020 #02-R, 04-R, 06-R, 08-R, 10-R, 12A -R, 14-R, 16-R Rated Accuracy: 0.05% Is (0.0305 in Hg) Range: 0-30 psia Resolution'. 0.01 Uncertainty: < 0.0358 #18-R, 20-R ADM #08-L Rated Accuracy: 0.05% is (00305 in Hg) Range: 0-60 in Hg Resolution: 0.001 Uncertainty: <0,0358 DIFFERENTIAL PRESSURE STANDARDS ADM #01-L SIN: 41739/42449 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 05/01/19 Due Date: 04/2020 ADM #01-R SIN: 41739/42446 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 05/01/19 Due Dale' 04/2020 ADM #02-1- SIN: 41741142454 Heise Model: PPM -i Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 05/01/19 Due Date: 04/2020 ADM #03A -L SIN: 45570/48451 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11/26/16 Due Date: 11/2019 AOM #03A -R SIN: 45570/48460 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11/28/16 Due Date: 1112019 ADM #04-L SIN : 41743/42456 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 11/28/18 Due Date: 11/2019 ADM #05-L SIN: 41740/42450 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Dale: 09/07/18 Due Date: 08/2019 ADM #05-R S/N. 41740/42447 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09113/18 Due Date: 0812019 ADM #06-1- SIN 41742/42455 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 09/07/18 Due Date: 0812019 ADM #07-L SIN: 42185142186 Heise Ni PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date. 03/26/19 Due Date: 0312020 ADM #07-R SIN: 42185/43326 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/26/19 Due Dale: 0312020 ADM #08-L SIN: 42186/43329 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 03/25/19 Due Date: 0312020 ADM #09-L SIN: 42202/43351 Heise Model: PPM4 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 01/23/19 Due Date: 01/2020 ADM #09-R SIN: 42202f,13350 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 01/23/19 Due Date* 01/2020 ADM #10-L SIN: 42203143353 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 01/23/19 Due Date: 01/2020 ADM #11-1- SIN: 43165144551-1 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date. 07/15/19 Due Date: 07/2020 ADM #11-R SIN: 43165/44730 Heise Moder PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 07/15/19 Due Date: 07/2020 ADM #12A -L SIN: 45605148490 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 07/16/19 Due Date: 07/2020 ADM #13-L SIN; 43415145041 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10/03/18 Due Date: 09/2019 ADM #13-R SIN: 43415145039 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10/04/18 Due Date' 09/2019 AOM #14-L SIN: 43412/45045 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 10/02/18 Due Date: 09/2019 ADM #15-1- SIN: 43416/45042 Heise Moder PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/22/19 Due Date: 02/2020 ADM #15-R SIN, 43416/45040 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/22/19 Due Date: 0212020 AOM #16-L SIN: 43413/45046 Heise Model: PPM -1 Mfgd by Dresser Industries Calibrated by Ashcroft Calibration Date: 02/21/19 Due Date: 0212020 ADM #tAl SIN: 44579/46842 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 05/16/19 Due Date: 0512020 ADM #17-R SIN : 44579146841 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 05/21/19 Due Date'. 05/2020 ADM #18-1- SIN : 44581/46846 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 05/16/19 Due Date: 06/2020 ADM #19-1- SIN: 44580/46844 Heise Model: PPM -i Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07/15/19 Due Date: 06/2020 ADM #19-R SIN: 44580146843 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 07/15/19 Due Date: 0612020 ADM #20-1- SIN'. 44582/46848 Heise Model: PPM -1 Mfgd & Calibrated by Ashcroft, Inc. Calibration Date: 06/18/19 Due Date: 06/2020 #01-L, 03A -L, 05-L, 07-L, 09-L, 11-L, 13-L, 15-1-, 17-L, 19-L Rated Accuracy: > 0.07% a (0.000175 in wc) Range: 0.0-0.25 in we Res,: 090001 Uncertainty: < 0.00035 #01-R, 03A -R, 05-R, 07-R, 09-R, 11-R, 13-R, 15-R, 17-R, 19-R Rated Accuracy: > 0,06% Is ( 0.003 in wc) Range: 0.0-5.0 in we Res.: 0.0001 Uncertainly: < 0.00348 #02-L, 04-L, 06-L, 08-L, 10-L, 12A -L, 14-1-, 16-L, 18-L, 20-L Rated Accuracy 10.06% is (0.03 in wc) Range: 0.0-50.0 in we Res.: 0.001 Uncertainty: < 0.0346 Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com ADM Cal Stnds Rev 14109124/18 1 of 2 08/09/19 Shortridge Instruments, Inc. AirData Multimeter Calibration Equipment Customer Order Number, Meter Serial Number, and Test Type are referenced on page 1 LOW VELOCITY EQUIVALENT CONFIRMATION STANDARDS Vel Eqv Transfer Standard SIN. 11,102009 Model ADM -870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 12/07/18 Due Date: 12/2019 Vel Eqv Transfer Standard SIN: M02903 Model ADM -870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 12/07/18 Due Dale: 12/2019 Vel Eqv Transfer Standard SM: M10839 Model ADM -870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 12/07/18 Due Date. 12/2019 Vel Eqv Transfer Standard SIN: M10840 Model ADM -870C Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 12/07118 Due Date: 12/2019 Vel Eqv Transfer Standard SIN: M10897 Model ADM -8700 Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 01/17/19 Due Date: 01/2020 Vel Eqv Transfer Standard S/N: M10901 Model ADM -870C Mfg'd & Calibrated by Shortridge Instruments, Inc. Calibration Date. 12/07/18 Due Date: 12/2019 Vel Eqv Transfer Standard SIN. M13492 Model ADM -870C Mfgd & Calibrated by Shodddge Instruments, ins. Calibration Date: 08/08/19 Due Date'. 08/2020 Vel Eqv Transfer Standard SIN : M19325 Model ADM -870C Mfgd & Calibrated by Shortridge Instruments, Inc.. Calibration Date: 06/21/19 Due Date: 0612020 Rated Accuracy: Velocity s 1.5 % 3 3.5 fpm Range: 100-5000 fpm Resolution: 0.1 Uncertainty: -5.00 fpm at 100 fpm, -7.50 fpm at 500 fpm TEMPERATURE STANDARDS RTD Simulator SIN : 249 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 03/16/16 Due Date: 03/2020 RTD Simulator SIN: 250 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 03/16/16 Due Date', 03/2020 RTD Simulator SIN : 253 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 03/16/16 Due Date: 03/2020 RTD Simulator SIN: 254 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/07/16 Due Date: 04/2020 RTD Simulator SIN: 256 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/07/16 Due Date: 04/2020 RTD Simulator SIN : 257 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/07/16 Due Date: 04/2020 RTD Simulator SIN: 292 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 12/21/15 Due Date: 12/2019 RTD Simulator SIN: 293 Model RTO -10001500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 12/21/15 Due Date: 12/2019 RTD Simulator SIN: 294 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 12)21/15 Due Date: 12/2019 RTD Simulator SIN: 313 Model RTD -10001500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 03/16/18 Due Date: 0312022 RTD Simulator SIN: 314 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 03/16/18 Due Date: 03/2022 RTD Simulator SIN: 315 Model RTD -1000/500 Mill by General Resistance Calibrated by IET Labs Calibration Date: 03/18/18 Due Date: 03/2022 RTD Simulator SIN: 316 Model RTO -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/16/18 Due Date: 04/2022 RTD Simulator SIN: 317 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/16/18 Due Dale: 04/2022 RTD Simulator SIN: 318 Model RTD -1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date: 04/16/18 Due Date. 04/2022 Rated Accuracy: 0.025% of setting Range: 100.00 D to 11111.10 R Resolution: 0.01 D Uncertainty: 5 32 ppm Thermometer #1 SIN BA089/Thermistor SIN A410660 Model 1504/5610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Dale: 08/16/17 Due Date: 0812019 Thermometer #2 SIN 8B104/Thermistor SIN 871507 Model 1504/5610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date: 11/07/18 Due Date: 10/2020 Thermometer #5 SIN 811780?hermistor SIN 810505 Model 1504/5610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date: 03/07)19 Due Date. 03/2021 Thermometer #6 SIN B 11782/Thermislor SIN 810509 Model 1504/5610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date: 02/20/18 Due Date: 0212020 Thermometer #7 SIN B49938rrhermistor SIN 8482202 Model 1504/5610 Mfgd and Calibrated by Fluke Calibration Date: 09/26117 Due Dale: 09/2019 Rated Accuracy(combined): 0.0324" F Range. 32' F to 176' F Resolution: 0.001" F Combined Uncertainty with Baths: s 0.040° F Temp Transfer Standard SIN M00136 Model ADM -870 Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 10/04/18 Due Dale: 10/2019 Temp Transfer Standard SIN M96100 Model ADM -870 Mfgd & Calibrated by Shortridge Instruments, Inc. Calibration Date: 03/07/19 Due Date: 03/2020 Rated Accuracy: 0.03' F Range: 33° F to 158' F Resolution: 0.01 ° F Uncertainty: - 0.023° F Total combined Uncertainty for MultiTemp and Tem Probe testing : s 0.046° F This form must remain with the Certificate of Calibration corresponding to the Customer Order Number and Meter Serial Number referenced on page 1. Shortridge Instruments, Inc. 7855 East Redfield Road Scottsdale, Arizona 85260 (480) 991-6744 • Fax (480) 443-1267 • www.shortridge.com ADM Cal Stnds Rev 14/09/24118 2 of 2 08/09/19 Order Number: V,\926 Model Number: Xbj�J- &GO Serial Number: Rattle inside of meter. Minor Repair not required. The following Minor Repair(s) checked below was/were performed prior to the As -Received meter readings. None of the Minor Repairs listed below affect the accuracy of the meter readings. Pushed dislodged reset button back into place Pushed dislodged ribbon cable assy back into its socket Replaced keypad (On, Mode or Read key nonfunctional) Replaced internal battery clip or wire Repaired broken wires that power the display Pushed dislodged IC back into its socket Replaced display that cannot be read Repaired broken wire that signals the flap jack Pushed dislodged J4 connector back into its socket Removed loose part from inside meter Broken piece of the meter housing Broken piece of a battery clip Broken piece of a display standoff Broken piece of wiring Dislodged PC board standoff screw Dislodged display board screw No other repairs were performed prior to taking As -Received meter readings. Minor repairs by: Date: `I lL CERTIFICATE OF CALIBRATION Customer Name: CERTIFIED AIR BALANCE Calibration Date: 08-12-2019 Address: UUT Calibration Due: 08-12-2020 PO Number: DM.STD. Calibration Fluid: 70F Instrument Manufacturer: FLUKE Standard(s) Used: A305 DUE 3-2020 InstiumentDescription: DIG. CLAMP MULTIMETER NIST Traceability Per: 1520239522 Model Number: FLUKE 323 Ambient Conditions: 763 winHGA 45% RH, 75F Serial Number: 45470323MV Procedure Number: NAVAIR-17-20AQ-103 Rated Uncertainty: +/- SEE TABLE Certificate/File Number: 491776 Uncertainty Given: AS REC./AS LEFT RESISTANCE +1-2% WITHIN SPECS* +1-1.5% 0 TO 400A *ALL RANGES AHrD FUNCTIONS WITHIN SPECS. 0 TO 400 OHM 0 TO 400 OHM REFERENCE CONDITIONS ARE: 760=tHGA 70F. INDICATED ACTUAL 01. 1bvnvd!-d mmp. 'II I.", pia, P[ INDICATED ACTUAL UUT DM.STD, N UUT DM.STD. DC VOLTAGE DC VOLTAGE gppontd 11, V, AC VOLTAGE AC VOLTAGE +1- 1% +1- 1.2% 0 TO 600V 0 TO 600V 0 TO 600V 0 TO 600V .4.0 24.02 110.1 110.03 AC CURRENT AC CURRENT -- RESISTANCE r RESISTANCE +1-2% +1-1.5% 0 TO 400A 0 TO 400A 0 TO 400 OHM 0 TO 400 OHM 2.37 1 2.369 47.2 47.1 All instruments used in the pertimnance of the shot�n calibration Ince traccabilit\ to the National Institute of Standards and Technology (NISTI. the uncermouV ratio behyecn the calibration standards (UAI.STD.) used and the unit under test ((.IUT) is a minimum of 4:1. unless othereise noted. Calibration has been performed per the shown procedure number. in accordance pith ISO 10012:2003. ISO 17025:201li. ANSI/NCSI.-Z-540.3_ and/or V111,-STU-45662A. lest methods: AP12530-92 & AS61E MFC -3M-1989. Dick Munns Company • 11133 Winners Circle • Los Alamitos, CA 90720 Phone(714)827-1215 n.n C'in.-I,,I 01. 1bvnvd!-d mmp. 'II I.", pia, P[ VI( n Mt NN s enMMNY rIx J" Am ""mann 3kmn "_. Ib1,N'. itiuk 10 m4_aa d ulnnum, N Date: gppontd 11, V, Calibration Technician'. Page I of CERTIFICATE OF CALIBRATION CUSTOMER: CERTIFIED AIR BALANCE: SANTA FE SPRINGS. CA CALIBRATION DATE: 06/25/2019 PO NUMBER: N/A CALIBRATION DUE: 06/25/2020 INST. MANUFACTURER: TSI PROCEDURE: T.O.33K6-0-1769-1 INST. DESCRIPTION: HYDRONIC MANOMETER CALIBRATION FLUID: AIR @ 14.7 PSIA 70°F MODEL NUMBER: HM685 RECEIVED CONDITION: WITHIN MFG. SPECS. SERIAL NUMBER: 71540130 LEFT CONDITION: WITHIN MFG. SPECS. RATED UNCERTAINTY: t 2% RD, AMBIENT CONDITIONS: 760 Into HGA 52% RH 70°F UNCERTAINTY GIVEN: ±,01 1 °% RD. I k = 2 CERTIFICATE FILE N. 486640.2019 NOTES: Q.MANUAL IM 1-5 REV 2017.1 DATED 7-18.2017 L UUTTSMD INDICATED_ PSID D. ACTUAL PSID t48 _ _ I 1.47 2.71 2.69 55.63 55.36 ___ _97.15 __. _ _ 96.60 -_ 'L151.39 _ 150.79 211.01 -� 210.13 _ -- 286.54 285.15 ._.--- —__----- — _ _____.. _.. .__—__ STANDARDS USED: STD. 6-- 600 PSI 1 t .011% RDI TRACE# 1520349429 1515224431 DUE TEMP. STANDARD -J-±.024 F I TRACE# 1520423238 DUE All instruments used in the performance of the shown calibration have traceability to the National Institute of Standards and Technology (NIST). the uncertainty ratio between the calibration standards (DM.STD.) used and the unit under test ((J(JIF) is a minimum of 4:I, unless otherwise noted. Calibration has been performed per the shown procedure number. in accordance with ISO 10012:2003. ISO 17025:2005. ANSI lNCSI- 7: 540.3. and/or VIII. STD -45662A. l est methods: AP12530-92 & ASME MFC -3M-1989. Rick Munns Company • 11133 Winners Circle • Los Alamitos, CA 90720 Phone (714) 827-1215 • Fax (714) 827-0823 /rv:; i_. I, I I I,.,,. .�a Date: Cahbrauon Technician: CERTIFIED AIR BALANCE CO. 9970 Belt Puwb [hie OM Senor Fe Springs, CA qO670 ES �.. C.S.I.780.573 jw YpS.vPa iPUv1P Section 5 Certifications Pdatw'(562)Wl-1208 Fat: 0itntr of (California Cnntracturs tatre 311-aner anrN Pursuant to Chapter 9 of Division 3 of the Business and Professions Code and the Rules and Regulations of the Contractors State License. Board, the Registrar of Contractors does hereby issue this license to: CERTIFIED AIR BALANCE COMPANY to engage in the business or act in the capacity of a contractor in the following classification(s): OQW C20 - WARM -AIR HEATING, VENTILATING AND AIR-CONDITIONING oerynwmar Consumer• AO'iSirs Witness my hand and seal this day, Signature of Licensee Signature of License Qualifier December 22,.1994 Issued December 21, 1994 Reg' of Consraoors This lien Is the prolwny of the RegtArar of [oneacton, is not transferrable, end sholl be returned to the Registrar upon demand when suspended, revoked, or invalidated for any reason. It becomes void if not renewed. 700573 License Number N "Itc NATIONAL ENERGY MANAGEMENT INSTITUTE COMMITTEE Acceptance Test Technician Certification Provider This certifies that CeitifwdAir Sarance 47resented 6y EdwardSantana jr. with -business focated at 9970 BelC94gncfi Tgg Santa To Springs, CR 90670 has successfully fu filfed the requirements of the California Code of 1kgufations 2013 Wife 24, Bart 1, Section 10-103-B and Bart 6 Section 120.5 as in force'on the date of the issue of this cenif:cate toperform nonresidentialmechanica!"acceptance tests as a 9VEMIC-Certified MechanicafAcceptanceTestBmpfoyer. June 02, 201 9WEE00020 9I&MICAEI"ICBAdministrator Issue (Date Certifiea ion 9Vttmfier DNlWS20 Sheet Metal and Air Conditioning Contractors' National Association Certifies that by participating in SNIACNA's 2014 Safety Excellence Awards' Program Awarded this 1st day o f August 2014 Director of Safety and Health Chief EzecUtive Offidei pert ftcact on EdwarrdSantana, Jr. HAS MET ALL REQUIREMENTS FOR NEBB CERTIFIED PROFESSIONAL STATUS IN THE FOLLOWING DISCIPLINE fisting, -gouting andBalancing ofl'nvironmmtalSystems This Certificate, as well as individual affiliation with a NEBB Certified Firm and associated NEBB Certification Stamp are REQUIRED to provide NEBB Certified Report. Participation inthe NEBB Quality Assurance Program requires the Certifcant be affiliated with a NERB Certified Firm. 24281 d NEBB Certification Number NEBB President Match 31, 2021 Expiration Date NEBB President -Elect NEBB Certification Board NEBB Certified Professional Edwarddl. Santana, Sr. , AS MET ALL THE NEBB REQUIREMENTS FOR NEBB CERTIFIED PROFESSIONAL STATUS IN fisting, Afisting and-Nafancing of nvironmentalSyctenu This Certificate, as well as individual affiliation with a NEBB Certified Firm and associated. NEBB Certification Stamp are REQUIRED to provide a NEBB Certified Report. Participation in the NEBB Quality Assurance Program requires the Certifieant be affiliated with a NEBB Certified Firm..' - March 31, 2020 Expiration Date 228]2 NEBB Certiticaut Number NEBB Certification Board Chairman Q 4r+�. NEBB Certification Director The NEBB Certification Beard retains sole o"ership of all certillcates. The NEBB Certification Board Polley Manual governs use of thiseertificate. . a NEBB Certification Board NEBB Certified Professional Edward .C. Santana, Sr. AS MET ALL THE NEBB REQUIREMENTS FOR NEBB: CERTIFIED PROFESSIONAL STATUS IN 2Vhole BuiWng Systems chn>calCommrss oning - YIYACSystems This Certificate, as well as individual affiliation with a NEBB Certified Firm and associated NEBB Certification Stamp are REQUIRED to provide a NEBB Certified Report. Participation in the NEBB Quality Assurance Program requires the Certifiaant be #11 fated with a NEBB Certified Firm.. Marchi 31, 20217 Expiration Date NEBB Certification Board Chairman 22872 - it cyutFh_- NEBB Certificant Number NEBB Certification Director The NEBB Certification Board retains sole ownership of off certificates. The NEBB Certification BoardPolicyManual governs use of this certificate. n2�a 1v1 1 ai,1, tail+ iV� 13B Rl (lUIREMENTS FOR NE' R CERTIFIED TECHNICIAN STATUS IN esting, Ai#iuting andBa,4nc ng f�nvironmentalSystems This, Cer fiflcate, as well as,individual affiliation with a NEBB Certified Firm and'aassoeiated^NEBb,c,ertification Stamp are,REQUIRED to provide a NEBB Certified Report] Participation in the NEBB,Quality Assurance Program requires the Certscant be affiliated with a NEBB Certiffed Firm. March 31, 2020 Expiration Date NEBB Certification Board Chairman 21483 Q NEBB Certificant Number.�-..e NEBB Certification D Director The NEBB Certification Board retains sole ownership of sit certificates. The NEBB Certification Board Policy Manual; governs use of this certificate. FOR THE SHEET METAL AND AIR CONDITIONING INDUSTRY CERTIFICATE OF COMPLETION CEC Title 24 Mechanical Acceptance Testing forms Edward L. Santana has successfully participated in the training fulfilling the requirements of the California Code of Regulations 2013 Title 24, Part 1 Section 30-103-B (b) B as in force on October 23, 2014 to complete the following nonresidential mechanical acceptance tests; i. NA7.51Dutdoor Air Ventilation Systems ii. NA7.5.2 Constant Volume, Single Zone Unitary Air Conditioners and Heat Pumps iii. NA7.5.4 Air Economizer Controls iv. NA7.5.5 Demand Control Ventilation Systems V. NA 7.5.6 Supply Fan Variable Flow Controls vi. NA7.5.7, NA7.5.9 Hydropic System Variable Flow Controls 1V vii. NA7.5.10Automatic Demand Shed Controls February 7, 2014 ITI Pr .ram Direct Date Recognized by: p N MIC una� e s nnsae�i unrne oo,nnFe �-. i '� N MIC g4l,gklLi lMligti Rx"Utut{P. as,I FWII 1A"MIA Acceptance Test Technician Certification Provider ,This certifies that Edward L. Santana A T -centfi'ed technician has successfully fu fiCCed the requirements of the California Code of W gufations 2013 Ttfe 24, (Part 1, Section 10-103-B (e)1 as in force on TFe6ruary 7, 2014 to compfete the following nonresidential mechanical acceptance tests: i. NA7.5.1OutdoorAir`UentirationSystems ii 5V47.5.2 Constant Volume, Singfe Zone `UnitaryAirConditioners and7feat (Pumps iii NA7.5.4Air Economizer Controfs iv. NA7.S.S(DemandControfVentif4tionSystems V. NA 7.5.6 Supply 'Fan Nana6le Plow Controls V4 NA 7.5.7 Valve Leakage Acceptance Iii Y4 7.5.9 7fydmnic System Vana6fe Elow Controls viii. NA75.10Automatic(DemandShedControfs December 8, 2014 VgIO055 NEMICA`TCBAdmimistrator Date of Issue Certification Number DKi120s 101 THE NATIONAL ENERGY MANAGEMENT INSTITUTE Certificate of Completion Edward Santana Jr. An officer of the Certified Air Balance Company, Inc. 9970 Bell Ranch Dr. Santa Fe Springs, CA 90670, has successfully completed the required training fulfilling the requirements of the California Code of Regulations 2016 Title 24, Part 1, sections 10-102 and 10-103, as well as Part 6, Section 120.5 to complete the nonresidential mechanical acceptance tests in accordance with Chapter 13 of the Nonresidential Compliance Manual of the 2016 California Building Energy Efficiency Standards issued Jan. 2017. NEMI Director of Training 1/6/2017 Date M I THE NATIONAL ENERGY MANAGEMENT INSTITUTE Certificate of Completion Edward Santana Jr. an officer of the Certified Air Balance 9970 Bell Ranch Rd. Santa Fe Springs, CA 90670 has successfully participated in the instructions fulfilling the requirements of the California Code of Regulations 2013 Title 24, Part 1, Section 10- 103-B on the Building Energy Efficiency Standards acceptance testing procedures and compliance documentation. 04tL- NEMI 6irectorofEducation 06/02/2015 Date