HomeMy WebLinkAboutX2018-2985 - Alternative Material & Methods- •..vc, n4tq ap G Daytime Phone 1 1 Daytime Phone f'�—t l�i• /�. 2 REQUEST: Suomd lens if nercessary to illustrate request. Additional sheets or data may be attached. !K U _ OUSTIFICATiONIFINDINGS u OF EQUIVALENCY: CODE SECTIONS. O 0 Au C _'505. Z- t/ D N A4 G a PeoOoner s Position r f 0 LsuT Signature CA Professlonal Uc a C0+12— % Dale 5 FOR STAFF USE ONLY DEPARTMENT ACTIONIn accordentx wim O CBC 1041 I/CFC 104.9 0 CBC 104.101CFC 104 8 (Alternate materials 8 methods) (CBC Modification) Concurrence from Fire Code Official is required. 0 Approved ❑ Disapproved O Written Comments Alteched BY Date 0 Request (DOES) (DOES NOTI lessen any fire protection requirements 0 RequeaYDOESf (DOES NOT) lessen the slrudural integrity The Request is Granted ❑ Denied (See reverse for /0 Granted (Ratification required) appeal information) Conditions of. Approval: Signalur position N ate �l�l dr,•.f.h Prim HeAKVArV—`77-- F DIVISION ACTIO TO THE BUILDING BOARD OF APPEALS (See Reverse) (Signature. 9lalenlBAt of owner or man)lalemen� tofreaaMsfol appeal fees are requited) CASHIER RECEIPT NUMBER: ^V I Fii mr nsdr caning COMMUNITY CITY OF NEWPORT BEACH CITY o \ DEVELOPMENT COMMUNITY DEVELOPMENT DEPARTMENT NOV 15 2019 6 BUILDING DIVISION s �aaonv�� 100 Civic Center Drivel PO. Box 1768 I Newport Beach, CA 92658.8915 WAW newoonbeachca my 1(949) 644.3200 CITY OF CASE NO.:,15 2`7C�� ��VJ�y01 � P ORT BE �' I REQUEST FOR MODIFICATION TO PROVISIONS OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE) FOR STAFF USE ONLY. OF THE NEWPORT BEACH MUNICIPAL CODE Pian Checks )4 d- L eaf Stone ) (See Reverse for Baas for Approval) (Fes 3294). REQUEST FOR ALTERNATE Occupancy Classification Use or Building SFU 9 of Units �— MATERIAL OR METHOD OF CONSTRUCTION Project Status rn/.. C-onr T2uc7 (See Reverse for Basis for Approval) (Fee 3294) Conslrudlun Type 7Ft3 S �.IA/iGLfG2_ REQUEST FOR EXEMPTION FROM DISABLED Verified by B'L. ACCESS TO PHYSICAL OR LEGAL No. of Items J fee due C CONSTRAINT if 37,6371 (Ratification by the Board of Appeals wit be requires I DISTRIBUTION. ❑ Owner ❑ Plan Check G HO Forabove requests, Complete Sections 1, 2 6 3 ❑ Petitioner ❑ Inspector below by printing In ink or typing. ❑Fire .❑Omer ITI JOB ADDRESS: .PETITIONER ADDRESS.. SITE ADDRESSf_ZSOI BUIV`)y}SI Petitioner _�7 ST, grt-j2.,+L Owner ICOM tl_ -rA•RKtS1.1•T4A (Porldoner meaanhlleetorma/nsed - •..vc, n4tq ap G Daytime Phone 1 1 Daytime Phone f'�—t l�i• /�. 2 REQUEST: Suomd lens if nercessary to illustrate request. Additional sheets or data may be attached. !K U _ OUSTIFICATiONIFINDINGS u OF EQUIVALENCY: CODE SECTIONS. O 0 Au C _'505. Z- t/ D N A4 G a PeoOoner s Position r f 0 LsuT Signature CA Professlonal Uc a C0+12— % Dale 5 FOR STAFF USE ONLY DEPARTMENT ACTIONIn accordentx wim O CBC 1041 I/CFC 104.9 0 CBC 104.101CFC 104 8 (Alternate materials 8 methods) (CBC Modification) Concurrence from Fire Code Official is required. 0 Approved ❑ Disapproved O Written Comments Alteched BY Date 0 Request (DOES) (DOES NOTI lessen any fire protection requirements 0 RequeaYDOESf (DOES NOT) lessen the slrudural integrity The Request is Granted ❑ Denied (See reverse for /0 Granted (Ratification required) appeal information) Conditions of. Approval: Signalur position N ate �l�l dr,•.f.h Prim HeAKVArV—`77-- F DIVISION ACTIO TO THE BUILDING BOARD OF APPEALS (See Reverse) (Signature. 9lalenlBAt of owner or man)lalemen� tofreaaMsfol appeal fees are requited) CASHIER RECEIPT NUMBER: ^V I Fii mr nsdr caning I --j SYMBOLS DETAIL IN rvumTN E - MB NUMBER %%%ONXXX KEYNOTE NUMBER SHEAR WALL, T-16 LENGTH PERPWN (REFER TO SHEET SN -1 FO RSCHEOULD (N) FOOTING (E)FOOTING Pk PAD FOOTING PER SCHEOUEF PAD FOOTING SCHEDULE OOF SO, x 20" THICK W(3) MG. TGE, E.W. O3B"SO.v AV THICK-DIPIT.B,EW. _36"50.n 2G" THICK"M)MS. T"' 'E' W. S. FOUNDATION NOTES 1. REFER TO SHEET SN -1 FOR ADDITIONAL INFORMATION. 2. HOLDOWN ANCHORS SHALL BE RE -TIGHTENED FUST PRIOR TO COVERING THE WALL FRAMING, 3, ALLHOLDOWN ANCHORS 3HAU BE TIED INPUCE PRIOR TOCALVNGFORAFOUNESU DN NSPECTION. AL ALL BOLT HOLES SHALL BE DRILLED IA2"TODIV OVERSIZED (12.1.3.y 2015 NOS) 5. AlJOSTING FOOTING SIZES, LOCATIONS, FK. HAVE BEEN ASSVMEDAND MUST BE VERIFIED IN THE FIELD BY THE 3 caurRAcrCR. 6. THE VAPOR BARRIER VN DER THE SLAB MUST CONFORM iO ASTM E I]05-9] AND BE INSTALLED PEBASTM E16<3-9 ERCS') Z. THE ENTIRE RF E%ISiING CON CRETE STAB SHALL BE COVER ED NTH AN APPROVED 'MBEPO%YCOATING"OREQUALIN ORDER iO PREVENT CIS TURF TRANSMISSION THROUGH S LAB AND INTO iH LIVING SPACE. t) r4,°+' f ps srrzucTuw L PCOHPORATE. 9]51 01, mp" L"', H �nting[on E -Th C 926 6 ] 1 h- 4 9 6. 6 7 2 pOFEBBp�/ t�s £ � Qae1Ra1 RESTRICTIVE NOTICE THRRVS D. "FLcFECK CLIENTREVS 10/25 \ PIANCHECK 11/15 5-1 11 11"xl,VlF CKw/MBAR1ATibB"ED- rl I,P"THILL.-ME AH. T&B.Ee W. S, 02"SO.v ME THICP-(4)ME,.B, FEW FOUNDATION NOTES 1. REFER TO SHEET SN -1 FOR ADDITIONAL INFORMATION. 2. HOLDOWN ANCHORS SHALL BE RE -TIGHTENED FUST PRIOR TO COVERING THE WALL FRAMING, 3, ALLHOLDOWN ANCHORS 3HAU BE TIED INPUCE PRIOR TOCALVNGFORAFOUNESU DN NSPECTION. AL ALL BOLT HOLES SHALL BE DRILLED IA2"TODIV OVERSIZED (12.1.3.y 2015 NOS) 5. AlJOSTING FOOTING SIZES, LOCATIONS, FK. HAVE BEEN ASSVMEDAND MUST BE VERIFIED IN THE FIELD BY THE 3 caurRAcrCR. 6. THE VAPOR BARRIER VN DER THE SLAB MUST CONFORM iO ASTM E I]05-9] AND BE INSTALLED PEBASTM E16<3-9 ERCS') Z. THE ENTIRE RF E%ISiING CON CRETE STAB SHALL BE COVER ED NTH AN APPROVED 'MBEPO%YCOATING"OREQUALIN ORDER iO PREVENT CIS TURF TRANSMISSION THROUGH S LAB AND INTO iH LIVING SPACE. t) r4,°+' f ps srrzucTuw L PCOHPORATE. 9]51 01, mp" L"', H �nting[on E -Th C 926 6 ] 1 h- 4 9 6. 6 7 2 pOFEBBp�/ t�s £ � Qae1Ra1 RESTRICTIVE NOTICE THRRVS D. "FLcFECK CLIENTREVS 10/25 \ PIANCHECK 11/15 5-1 PRODUCT DATA SHEET Sika° MB SOLVENT FREE, EPDXY MOISTURE BARRIER PRODUCT DESCRIPTION Sika® MB is a 2 -component, solvent free, low viscosity, epoxy for use under wood flooring products, self level- ing underlayments, floating floors and other flooring sys- tems that require protection from subfloor moisture. USES • Moisture barrier to help control moisture propagation in cementitious substrates with a moisture content not exceeding 6 %by Tramex Method and residual mois- ture up to 100 % R.H. or 25 Ib/1,000 ft2/24 h (11.4 kg/92.9mz/24 h) • For substrate consolidation on concrete, cement and gypsum screeds • Adhesion promoter for old and new adhesive residues in conjunction with other Sika® products • Suitable on concrete, cement, self -leveling and gypsum substrates, OSB, plywood, quarry and terrazzo tiles, water-soluble adhesive and cutbacks PRODUCT INFORMATION CHARACTERISTICS / ADVANTAGES • Solvent -free (100 % solids) • Easy roller applied application, low viscosity • Convenient, easy to mix packaging • Shorter construction periods • Excellent penetration and stabilization of the substrate • Reduction of adhesive consumption • Suitable for use on floors with radiant heating • Compatible with Sika Bond® wood flooring adhesives, Sika® Level products • Can be used below floating floors APPROVALS / STANDARDS Meets ASTM F 3010 Chemical Base Two component epoxy Packaging 2.64 gal (10 L) pail Color Blue Shelf Life 24 months from date of production if stored properly in undamaged sealed containers Storage Conditions Store dry at 50-77 °F (10-25 "C). Protect from moisture. Density 69 l b/ft3 (1.1 kg/1) Product Data Sheet Sika® M8 December 2018, Version 01.03 020512081000000017 1/4 TECHNICAL INFORMATION Shore D Hardness 7 days 83 (mixed A&B) (ASTM D-2240) Compressive Strength 7 days 10,000 psi (69 MPa) 73'F (23 "C) 50 % R.H. Permeability to Water Vapor 0.06 g/m2-24hour-mmHG (ASTM E-96) Service Temperature -40-158 7 (-40-70 "C) APPLICATION INFORMATION Coverage Coverage per pail Moisture barrier 250-300 ftz (23.2-27.9 M2). Adhesion promoter or 400-450 ftz (37.2-41.8 m2) surface consolidator (Coverage figures do not include allowance for surface profile and porosity or material waste). Application Recommended Results in Coatings Moisture barrier only min. 1 Mirror like finish Substrate min. 1 Good penetration consolidation only Adhesion promotion min. 1 Mirror like finish Moisture barrier+ min. 2 Mirror like finish substrate consolidation Moisture barrier+ min. 2 Mirror like finish adhesion promotion MUST produce a monolithic, pinhole -free finish with a continuous film. The need for multiple coats is directly related to surface absorption. Pot Life 50 °F (10 -C) - 60 minutes 68 7 (20 `C) - 30 minutes 86 7 (30 "C) - 15 minutes Cure Time 50 °F (10 °C) 18 hours 73 7 (23 "C) 8 hours 86 -F (30 °C) 6 hours *minimum curing time, prior to walking on primer/or for applying Sika Bond' or Sika' Level. Application Time Overcoating Applica- Minimum Maximum tion Time Window* Sika* MB 8 hours 36 hours (2nd coat) *When Sika° MB is left an the substrate for more than the maximum allowable open time, the surface must be mechanically prepared (i.e. sanded) solvent wiped before proceeding. Product Data Sheet Sikes MB December 2018, Version 01.03 020512081000000017 2/4 BUILDING TRUST APPLICATION INSTRUCTIONS SUBSTRATE PREPARATION • Substrate must be clean, dry, sound and homogeneous, free from oils, grease, dust, and loose or friable particles. Paint, laitance, and other poorly adhering contents must be mechanically removed. • Substrate must have an open textured surface to allow Sika® MB to penetrate. (i.e. Blast cleaning, grinding are considered acceptable means to achevie the desired surface profile. Acid and chemical etching are not ac- ceptable). • At least 50 % of the surface area must be cleared of re- sidual adhesive and cutbacks. (i.e. by grinding or mech- anical substrate preparation) • Old cutback can contain asbestos which is dangerous for the health so do not grind, sand or blast. Refer to the Resilient Floor Covering Institute's publication "re- commended work practice for removal of resilient floor coverings" for instruction. • Minimum substrate compressive strength > 1,160 psi. Tensile Bond strength > 116 psi at the time Sika® MB is applied. • Repair with Sika® Level SkimCoat or SikaQuicko mortar before priming. • The floor must be cleaned with an industrial vacuum prior to installation of the Sika® MB. • On fiber reinforced concrete, fibers should be flamed off the surface prior to application of Sika® MB as a moisture barrier. • Before overall installation begins, Sika® recommends the application of several small test patches to determ- ine primer application requirements and acceptability of final product performance. MIXING • Add one full can of component A to one full can of component B then mix with an electric drill and mixing (Jiffy Mixer type) paddle at a low speed to reduce air entrainment (300-400 rpm). Using a paint stick or sim- ilar is not sufficient to mix the primer. • A minimum mixing time of 3 minutes shall be observed; mixing shall continue until a homogeneous mix has been achieved. • Scrape sides of pail with paint stick or paddle to ensure all contents are thoroughly mixed together. • Unmixed material applied to the floor will not cure properly. APPLICATION METHOD/ TOOLS • Apply Sika® MB uniformly (in 2 directions 90") to the substrate using a medium nap roller, ensuring that a continuous coat is achieved over the entire surface (MUST produce a mirror like finish). • Pour contents of pail onto the floor for best working time. Attempting to work from the pail will reduce working time. • When used as a moisture barrier and substrate consol- Product Data Sheet Sika® MB December 2018, Version 01.03 020512081000000017 314 idation / adhesion promotor, prepare the substrate mechanically as in accordance with the guidelines stated in subtitle "Surface Preparation". Apply the first coat at 10 mils Apply the second coat at 15 mils in ac- cordance with the open time*. 2 coats application: Apply the first coat at 75-115 ft2/gal Apply the second coat at 150-225 ft2/gal in accordance with the application time window*. Then follow one of the option: • Option 1: Broadcast to refusal with oven dried silica sand (20/30) on the second coat immediately. Sweep sand once the epoxy is cured. Apply Sika® Level products on cured epoxy. • Option 2: Apply Sika® Level -02 EZ Primer in accordance with the application time window*. When the primer is dry, apply Sika® Level products. *ref. to appliction time in sections above CLEANING OF TOOLS • Clean all tools and application equipment with clean- ing solvent (Xylene, MEK are effective). • Hardened/cured material can only be removed mech- anically. LIMITATIONS • Proper coverage must be used to achieve moisture bar- rier properties. • Will not act as a moisture barrier for gypsum screeds. Gypsum based subfloors are very susceptible to excess moisture and will be degraded if exposed to excess moisture from below or above. • Only protects from moisture coming from below the concrete. • Will not prevent hydrostatic pressure. • Must not be applied to a visibly wet substrate. • Does not prevent moisture occurring between the epoxy and the floating floor due to secondary sources of moisture or acclimation, e.g. water condensation. • Is not suitable for use with bonded systems due to pos- sible curing and adhesion problems. • Sika® recommends the use of Sika® Level products on top of it. • Floor covering manufacturer's and Wood flooring man- ufacturer's recommendations, like room humidity levels and wood acclimation requirements should be strictly followed. • Sika® does not make any standing recommendations as to the structural integrity of old adhesive residues or subflooring materials that are not manufactured by Sika®. • When left on the substrate for more than the maxim- um allowable open time of 36 hours, prior to placing the adhesive, the surface must be thoroughly cleaned and mechanically prepared (i.e. screened sand) and solvent wiped. Failure to do this, may result in adhe- sion problems. For detailed instruction contact our Technical Service. When used in conjunction with Sika - BUILDING TRUST Bond®, Sika® MB does not need to be broadcasted with sand. y BASIS OF PRODUCT DATA Results may differ based upon statistical variations de- pending upon mixing methods and equipment, temper- ature, application methods, test methods, actual site conditions and curing conditions. OTHER RESTRICTIONS See Legal Disclaimer. ENVIRONMENTAL, HEALTH AND SAFETY For further information and advice regarding transporta- tion, handling, storage and disposal of chemical products, user should refer to the actual Safety Data Sheets containing physical, environmental, toxicological and other safety related data. User must read the cur- rent actual Safety Data Sheets before using any products. In case of an emergency, call CHEMTREC at 1- 800-424-9300, International 703 -527 -3887 - Sika Corporation Sika Mexicana S.A. de C.V. 201 Polito Avenue Carretera Libre Celaya Km. 8.5 Lyndhurst, NJ 07071 Fracc. Industrial Balvanera Phone: 800-933-7452 Corregidora, Queretaro Fax: 201-933-6225 C.P. 76920 Phone: 52 442 2385800 Fax: 52 442 2250537 M Product Data Sheet Sika- MB December 2018, Version 01.03 020512081000000017 LEGAL DISCLAIMER • KEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY • FOR PROFESSIONAL USE ONLY Prior to each use of any product of Sika Corporation, its subsidiaries or affiliates ("SIKA"), the user must always read and follow the warnings and instructions on the product's most current product label, Product Data Sheet and Safety Data Sheet which are available at usa.sika.com or by calling SIKA's Technical Service De- partment at 800-933-7452. Nothing contained in any SIKA literature or materials relieves the user of the oblig- ation to read and follow the warnings and instructions for each SIKA product as set forth in the current product label, Product Data Sheet and Safety Data Sheet prior to use of the SIKA product. SIKA warrants this product for one year from date of in- stallation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within the product's shelf life. User determines suitability of product for intended use and assumes all risks. User's and/or buyer's sole remedy shall be limited to the purchase price or replace- ment of this product exclusive of any labor costs. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL AP- PLY INCLUDING ANY WARRANTY OF MERCHANTABIL- ITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTH- ERS. Sale of SIKA products are subject to the Terms and Con- ditions of Sale which are available at https://usa.sika.com/en/group/SikaCorp/termsandcon- ditions.html or by calling 201-933-8300. Sika Canada Inc. 601 Delmar Avenue Pointe Claire Quebec H9B 4A9 Phone: 514-697-2610 Fax: 514-694-2792 BUILDING TRUST 4/4 SikaMB-en-US-(12-2018)-1-3odf 0