Loading...
HomeMy WebLinkAboutX2017-3513 - Miscto[ 3;O� l::i- X2017-3593 .218 ProsPeC4 54 �('vv✓� �U-�'0`e�/1 �ri2v-2- . 2-1 c �o^ifNC��w Com 0 a r,- ProJ ec f - p�- 29 POt- CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 3300 Newport Boulevard I P.O. Box 1768 1 Newport Beach, CA 92658 www,newoortbeachca.gov 1 (949) 644-3275 SETBACKS AND TOP OF SLAB/FLOOR ELEVATION CERTIFICATE The purpose of this certificate is to: insure that the structure is located properly on site per the approved drawings. This certificate also verifies the top of slab/floor elevation noted on the approved drawings. After the top of slab/floor elevation is verified to match the elevation specified on the approved drawings, the contractor and inspector can measure the height of the structure to the top of slab/floor to verify that it is equal or less than the dimension shown on building sections and elevations. This form must be filled out by a registered surveyor or civil engineer authorized to perform surveys. The survey must be done after the concrete forms are in place or preferable after the concrete slab is poured or raised floor is built, but prior to starting wall framing. Engineer/Surveyor's Name Mike Fokert License # LS 5662 Engineer/Surveyor's Address 22311 Brookhurst St, Ste 203, H.B. CA 92646 Job Address 218 Prospect Street Setbacks:, Sketch a site plan and specify surveyed setbacks (use back page). * Top of slab/floorelevation: 10.32' * If slab/floor elevation varies, sketch a'plan or section through slab on the back page and specify the elevations. Use same datum used in the survey of record. I certify that the setbacks are ®, are not 0, per City approved plans. Describe any deviations from plans: I certify that top of slab/floor elevation(s) is ®, is not ❑, per City approved drawings. Describe any deviations from plans: 11/9/17 Date Fortes/SetbacksandTopofSlabElevationCert. PROSPECT STREET ALLEY CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 BUILDING HEIGHT CERTIFICATION Project Street Address: 218 Prospect Street, Newport Beach CA 92663 Building Permit Number(s): X2017-3513 As the surveyor of record for the project at the above address, I hereby certify that I have reviewed the City of Newport Beach approved plan and original topographic survey and based the elevations listed below on those plans. Elevations shall include an allowance for roofing material thickness if not yet installed. Provide each critical ridge and flat roof, or roof deck railing elevations indicated on the approved plans. Use the format below on the back of this form if additional space is necessary or further explanation is needed. Provide original copy to the inspector before roof framing inspection. All elevation points are based on: lJ NAVD88 O NGVD29 O Assumed Please provide the following elevation information for the highest roof ridges, flat roofs, or parapets/guardrails. Additional elevation points may be requested by the Building Inspector. RIDGES (3:12 slope or greater) 38.80+0.02(Roof Material) 1. Approved elevation point of ridge is 38.85 and actual elevation point is 38.82 2. Approved elevation point of ridge is and actual elevation point is 3. Approved elevation point of ridge is and actual elevation point is FLAT ROOFS, PARAPETS AND GUARDRAILS 33 85 Parapet Deck 1. Approved elevation, point of flat roof or parapets and actual elevation point is 33.82 , 2. Approved elevation point of flat roof or p apet is and actual elevation point is . 3. Approved elevation point of flat roof or parapet is and actual elevation point is I certify that th above height measurements are correct and the above project: WS in compliance with the City -approved plans. OIS NOT in compliance with the City -approved plans (Provide explanation). Please describe any deviation from the City -approved plans on the back of this form. Surveyora Civil Engineer's* signature and seal (Wet stamp and signature required) * License number of 33965 or lower Farms\Building Height Certification 11/02/16 �t No. 4599 118118 Date XX17.3513 1219 pro Sped S4 CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.aov 1 (949) 644-3200 Structural Observation Report Project ddress: ro� �( �, . Report Date: Y �y ` CNB Inspector Name: CNB Permit* Bull di Owner Name: I Owner's Mailing Address (if different from site); Owner's Telephone #: CNB Plan Check #: ❑ Steel ❑ Concrete Full Name of Structural Observer (SO : SO E-mail Address: S9 Telephone #: SO License / Reg. #: CZ t ❑ Caissons, Piles, Grade Beams Wood orManuf. '\ Shear Panels PLEASE INDICATE STRUCTURAL ELEMENTS AND CONNECTIONS ORSPRVPn k ----Y FOUNDATIONS SHEAR WALLS FRAMES DIAPHRAGMS (Floor/Roof) INDICATE LOCATION(S) OBSERVED DATE OBSERVED ❑ Conventional Footings & Slab ❑ Concrete ❑ Steel ❑ Concrete ❑ Mat Foundation, Prestressed Concrete ❑ Masonry ❑ Concrete ❑ Steel Deck ❑ Caissons, Piles, Grade Beams Wood orManuf. '\ Shear Panels ❑Masonry ❑ —wood V5l47— / 1 l_ d I lcvr'T El Other: El Other: ❑Other: ❑Other: XITEMS CHECKED ABOVE ARE APPROVED AND WITHOUT DEFICIENCIES. ❑ OBSERVED DEFICIENCIES AND COMMENTS: InV44rel'fa.e'a ❑ REPORT CONTINUED ON ATTACHED PAGES. ❑ FINAL STRUCTURAL OBSERVATION REPORT: The structure generally compiles with the approved construction documents, and all observed deficiencies were corrected. I declare that the following statements are true to the best of my knowledge: 1. 1 am the licensed design professional retained by the owner to be in responsible charge of the structural observation; 2. I, or another licensed design professional whom I have designated above and is under my responsible charge, have performed the required site visits at each significant construction stage to verify that the structure is in general conformance with the approved construction documents; 3. 1 understand that all deficiencies which I have documented must be corrected, prior to final acceptance of the structural systems by the City of Newport Beach, Building Division. ,,, A A ��QQOFISSlOyq� S.✓q W m No. C83129 Exp. 03-3 - 9 l9TF/ E N JF s Of CAI\ CNED STAMP OF STRUCTURAL OBSERVER STRUCTURAL OBSERVATION DOES NOT WAIVE ANY REQUIREMENTS FOR BUILDING INSPECTION BYAUTHORIZED EMPLOYEES OF THE CITY OF NEWPORT BEACH. Potms\Stm=mlObs wtioN epoft Instmdions CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.aov 1 (949) 644-3200 Structural Observation Report Project Address: I_ Report Date: CNB Inspector Name: CNB Permit#: Buil �ng Owndr Name Owner's Mailing Address (if different from site); Owners Telephone #: CNB Plan Check #: �rIL� cr4IACV7e-e.. ❑ Concrete Full Name of. Structural Observer (S ): SO E-mail Address: SO Telephone #: SO License / Reg. #: cL ��>� - r 2 Lf3�2 kf Wood or Manuf. IN, Shear Panels ❑ Masonry ❑ Wood f f L"�I�Sr�Cd S )fit PLEASE INDICATE STRUCTURAL ELEMENTS AND CONNECTIONS OBSERVED (check applicable boxes) FOUNDATIONS SHEAR WALLS FRAMES DIAPHRAGMS (Floor/Roof) INDICATE LOCATION(S) OBSERVED DATE OBSERVED ❑ Conventional Footings & Slab ❑ Concrete ❑ Steel ❑ Concrete ❑ Mat Foundation, Prestressed Concrete ❑ Masonry ❑ Concrete ❑ Steel Deck ❑ Caissons, Piles, Grade Beams kf Wood or Manuf. IN, Shear Panels ❑ Masonry ❑ Wood f f L"�I�Sr�Cd S )fit ❑ Other: ❑ Other: ❑ Other: ❑ Other: ITEMS CHECKED ABOVE ARE APPROVED AND WITHOUT DEFICIENCIES. ❑ OBSERVED DEFICIENCIES AND COMMENTS: n "' dipefrC ❑ REPORT CONTINUED ON ATTACHED PAGES. FINAL STRUCTURAL OBSERVATION REPORT: he structure generally complies with the approved construction documents, and all observed deficiencies were corrected. I declare that the following statements are true to the best of my knowledge: 1. I am the licensed design professional retained by the owner to be in responsible charge of the structural observation; 2. I, or another licensed design professional whom I have designated above and is under my responsible charge, have performed the required site visits at each significant construction stage to verify that the structure is in general conformance with the approved construction documents; 3. 1 understand that all deficiencies which I have documented must be corrected, prior to final acceptance of the structural systems by the City of Newport Beach, Building Formst tmctmalOb ervationR poftMmtructiorts ESS No, C83129 Exp. 0 i"D NEO - STAMP OF STRUCTURAL OBSERVER WAIVE ANY REQUIREMENTS FOR BUILDING INSPECTION BY AUTHORIZED EMPLOYEES OF THE CITY OF NEWPORT BEACH. CITY OF NEWPORT BEACH COMMUNM DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportheachea.gov 1(949) 6443200 Structural Observation Report Project Address: Report Date: h/12©/' CNB Inspector Name: CNB Permit #., :74 iris 15�j - DATE OBSERVED Conventional Footin s & Slab ❑ Concrete Buildi Owner Name: Owners Me" Address (it different from site); Owners Telephone+F: CNB Pian Check '% eX)e— AC ❑ Masonry ❑ Concrete ❑ Steel Deck Full Name of Structural Observer (SO): SO Email Address: SO Telephone is SO License / Reg, #: cf � u3Ge,aMM 24-139-41214 C-251)2- PLEASE INDICATE STRUCTURAL ELEMENTS AND CONNECTIONS OBSERVED !check anolicabta hoxesi FOUNDATIONS SHEARWALLS FRAMES DIAPHRAGMS (FloortRoof) INDICATELOCATION(S) OBSERVED DATE OBSERVED Conventional Footin s & Slab ❑ Concrete ❑ Steel ❑ Concrete ❑ Mat Foundation, Prestressed Concrete ❑ Masonry ❑ Concrete ❑ Steel Deck ❑ Caissons, Piles, Grade Beams ❑ Wood or Manuf. Shear panels ❑ Masonry ❑ Wood ❑ Other. ❑ Other. ❑ Other. 17 Other. ITEMS CHECKED ABOVE ARE APPROVED AND WITHOUT DEFICIENCIES. O OBSERVED DEFICIENCIES AND COMMENTS: ❑ REPORT CONTINUED ON ATTACHED PAGES. ❑ FINAL STRUCTURAL OBSERVATION REPORT: The structure generally complies with the approved construction documents, and all observed deficiencies were corrected. I declare that the following statements are true to the best of my knowledge: 1. 1 am the licensed design professional retained by the owner to be in responsible- charge esponsiblecharge of the structural observation; 2. I, or another licensed design professional whom I have designated above and is under my responsible charge, have performed the required site visits at each significant construcgon stage to verify that the structure is in general conformance with the approved conduction documents; 3. 1 understand that all deficiencies which 1 have documented must be corrected, prior to final acceptance of the structural systems by the City of Newport Beach, Building Division. _ , %.S1wd0keervaVonRepotl&Jofl,uc . STAMP OF STRUCTURAL OBSERVER FOR BUILDING INSPECTION BYAIRHORVED FMPLOYEFS OF TNF CRY nP NFWPnRT RFACN City of Newport Beach Special Inspector Manual CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658 www riewoortbeachca.00v (949) 644-3200 SPECIAL INSPECTION REPORT Project Address: d -t 6 l.( Permit Number: - Inspection Type (s): �� 0 Inspection Date (s): (J ( ) Periodic (y) Continuous List Tests Made: Total Inspection Time Each Day: Date:. to —';� 1 Hours: Pf(%1- List All ItenJA Requiring correction (Include Previously Listed Uncorrected Items): Comments: l l S 0-� To the best of my knowledge, the work inspected was In accordance with the Building Division approved design drawings specifications and applicable workmanship provisions of the U.B.C. except as noted above. :Special Inspector Signature: - - Describe Inspection,. Including. Location(s):. p Print Ful e: Newport Beach Registration No.: 'tom L--vJr l y s 9 A evvPj _ �' C t�xiy r'G cu c. "ra 2LtJ 0 tri it '6S O&F I l SO h � . S � � rVdTlA)(� fuw (� Cn" YvJ c�!/4o l 56LIF-y d a , 144u,s G List Tests Made: Total Inspection Time Each Day: Date:. to —';� 1 Hours: Pf(%1- List All ItenJA Requiring correction (Include Previously Listed Uncorrected Items): Comments: l l S 0-� To the best of my knowledge, the work inspected was In accordance with the Building Division approved design drawings specifications and applicable workmanship provisions of the U.B.C. except as noted above. :Special Inspector Signature: Date: Print Ful e: Newport Beach Registration No.: U�C- 1\)i30�a J Speclallnspectlonfleport 08/25/2015 67 M CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 Structural Observation Report Project Address: :2c w€7 efe ��ii�xfi Report Date: oz & CNB Inspector Name: CNB Permit* Building Owner Name: Owner's Mailing Address (if different from site); Owners Telephone #: CNB Plan Check A Full Name of Structural Observer (SO): SO E-mail Address: SO Telephone #: SO License / Reg. M &� ❑ Masonry ❑ Concrete ❑ Caissons, Piles, Grade Beams ❑ Wood or Manuf. Shear Panels PLEASE INDICATE STRUCTURAL ELEMENTS AND CONNECTIONS OBSERVED (check applicable boxes) FOUNDATIONS SHEAR WALLS FRAMES DIAPHRAGMS (Floor/Roof) INDICATE LOCATION(S) OBSERVED DATE OBSERVED ❑ Conventional Footings & Slab ❑ Concrete ❑ Steel ❑ Concrete ❑ Mat Foundation, Prestressed Concrete ❑ Masonry ❑ Concrete ❑ Steel Deck ❑ Caissons, Piles, Grade Beams ❑ Wood or Manuf. Shear Panels ❑ Masonry Wood wl-❑ 21 Owl - El Other: ❑ Other: ❑ Other: ❑ Other: ITEMS CHECKED ABOVE ARE APPROVED AND WITHOUT DEFICIENCIES. ❑ OBSERVED DEFICIENCIES AND COMMENTS: 211-���=� �e•� ❑ REPORT CONTINUED ON ATTACHED PAGES. ❑ FINAL STRUCTURAL OBSERVATION REPORT: The structure generally complies with the approved construction documents, and all observed deficiencies were corrected. I declare that the following statements are true to the best of my knowledge: 1. I am the licensed design professional retained by the owner to be in responsible charge of the structural observation; 2. I, or another licensed design professional whom I have designated above and is under my responsible charge, have performed the required site visits at each significant construction stage to verify that the structure is in general conformance with the approved construction documents; 3. 1 understand that all deficiencies which I have documented must be corrected, prior to final acceptance of the structural systems by the City of Newport Beach, Building Division. , u Forms\ tmmmlob Ce tloN eport& stmctiom Q�iOEESS/py9� R S..1,q Fac _W m No. C83129 m * Exp. 03-3 9 f9T� N��Q FOF CA�\`` 9/NNEB t� STAMP OF STRUCTURAL OBSERVER NOT WAIVE ANY REQUIREMENTS FOR BUILDING INSPECTION BY AUTHORIZED EMPLOYEES OF THE CITY OF NEWPORT BEACH. CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.aov 1 (949) 644-3200 Structural Observation Report Project Address: "`i6i - ' CSG` 'Gly,,. 'o Report Date: ` CNB Inspector Name: CNB Permit #: Bui ' Owner ame: Owner's Mailing Address (if different from site); Owner's Telephone #: CNB Plan Check* riev est eRc- ❑ Concrete Full Name of Structural Observer SO): SO E-mail Address: SO Telephone #: SO Ljpens Reg. #: 6 7 71 _ 123 4 - PLEASE INDICATE STRUCTURAL ELEMENTS AND CONNECTIONS OBSERVED (check applicable boxes) FOUNDATIONS SHEAR WALLS FRAMES DIAPHRAGMS (Floor/Roof) INDICATE LOCATION(S) OBSERVED DATE OBSERVED ❑ Conventional Footings & Slab ❑ Concrete ❑ Steel ❑ Concrete ❑ Mat Foundation, Prestressed Concrete ❑ Masonry ❑ Concrete ❑ Steel Deck ❑ Caissons, Piles, Grade Beams ❑ Wood or Manuf. Shear Panels ❑ MasonryWcod t^K�1P oTTf >2l% 7 ❑ Other: ❑ Other: ❑ Other: ❑ Other: ITEMS CHECKED ABOVE ARE APPROVED AND WITHOUT DEFICIENCIES. ❑ OBSERVED DEFICIENCIES AND COMMENTS: REPORT CONTINUED ON ATTACHED PAGES. ❑ FINAL STRUCTURAL OBSERVATION REPORT: The structure generally complies with the approved construction documents, and all observed deficiencies were corrected. I declare that the following statements are true to the best of my knowledge: 1. I am the licensed design professional retained by the owner to be in responsible charge of the structural observation; 2. I, or another licensed design professional whom I have designated above and is under my responsible charge, have performed the required site visits at each significant construction stage to verify that the structure is in general conformance with the approved construction documents; 3. 1 understand that all deficiencies which I have documented must be corrected, prior to final acceptance of the structural systems by the City of Newport Beach, Building DOES NOT WAIVE ANY Fotmst tmdumlobser tiord epoaCmtructiom W m No. C83129 '. \Exp. ,03-31- 9 TF FOP fNl\F � S16NE0 - STAMP OF STRUCTURAL OBSERVER BUILDING INSPECTION BY AUTHORIZED EMPLOYEES OF THE CITY OF NEWPORT BEACH. January 4, 2018 Att.; Planning and Building Department- City of Newport Beach, CA 92658 Project Name: Grieve Residence Address: 218 Prospect Street, Newport Beach, CA 92663 Plan Check No.; 1992-2017 Re: Diaphragm Boundary Nailing fix To Whom It May Concern: During my structural observation to the above-mentioned site, to perform the observation of the first -floor diaphragm, the floor sole pate was installed and could not verify the Diaphragm boundary nailing. Leyva construction has confirmed the boundary nailing was in accordance with the approved construction documents. With that being said, and to ensure the diaphragm boundary nailing complies with the approved construction documents, we added 16d nails at 4 inches on center form top of sole plate to blocking below at both sides of the diaphragm and Simpson SDS %dk 6" long screws at 4 inches on center at the other sides where double -sided shear walls where occurs per plan. If you have any questions regarding this matter, please do not hesitate to contact me. Regards, Bashar Jamil, P.E. (714)-883-4124