HomeMy WebLinkAboutS2018-0147 - Misc30/009 CHRISTOPHER JEAN & ASSOCIATES, INC. ACOUSTICAL CONSUL.'I'ING SERVICES S)018 - ()1147 309 Via / ,Jo Soul January 24, 2020 MR. THOMAS THOMAS INFINITY POOL, & SPA, INC. 840 West 19th Street Costa Mesa, California 92627 Business License: #BT30044674 SUBJECT: RESULTS OF ACOUSTICAL CERTIFICATION MEASUREMENT FOR 301 VIA LIDO SOUD -- CITY OF NEWPORT BEACH Dear Mr. Thomas: We are pleased to inform you that the pool equipment installation located at 301 Via Lido Soud in the City of Newport Beach complies with the City's 55 dBA noise limit. No additional noise mitigation is necessary. The installation was measured on Friday, January 24, 2020, using a Larson Davis Model 700 Type 2 Sound Level Meter. The installation was observed to consist of a single Jandy VS Plus pump, a single Jandy Water Feature pump and a Mastertemp 400 heater unit, all located in a mechanical closet. The measurement microphone was placed at the top of the nearest property line wall directly opposite the mechanical closet. The measurement reported a level of 51 dBA with both pumps and the heater unit operating simultaneously. This level complies the City's 55 dBA noise limit. Thank you, and if there are any questions, please do not hesitate to call. Clitrstophcr;Jea' a President P. �O. BOX 2325 • FULLERTON, CALIFORNIA 92837 "� PHONE: 714-805-0115 i Continuous Inspection di Materials Testing vrr®ssv®- SLTTH ST Inspection & Testing, 11ic. 841 Commercial Way, La Habra, CA 90631-6168 (562)941-2990 ° (714)526-8441 t FAX (562)946-0026 FIELD DATA ON TEST SPECIMENS -- ASTM C31, C138, C143, C172, C173, C231, C1064 --- CONCRETE: MORTAR: SHOTCRETE: X CORES: GUNITE: ADDRESS: 301 VIA LIDO SOLID, NEWPORT BEACH JOB #: DATE: 05/1612019 JOB NAME: FEUERSTEIN PERMIT #: S2018-0147ISSUED BY: ARCHITECT: ENGINEER: FERRELL CONTRACTOR: INFINITY POOLS SUB: GOLD COAST SHOTCRETE LOCATION IN STRUCTURE: FLOOR OF THE POOL TRACT: PHASE: LOT #: CONCRETE SUPPLIER: NATIONAL RDY MX PLANT: MIX#: 7 1/2 1 TYPE OF CEMENT:'V ADMIXTURE: TICKET #: 308955 SLUMP: 0.00 in. WATER ADDED: 0 gal. AIR TEMP: 0 F CONCRETE TEMP:: MIXING TIME: TIME CAST: 12:00 DATE CAST: 04/15/2019 RECEIVED AT LAB: 04/25/2019 SPECIMENS MADE BY: KELLY LUIZ SPECIFIED PSI @ 28 Days: 4500 LAB #: 140813 CLIENT: RICHARD LUIZ TESTING INFORMATION: SAMPLE IDENTIFICATION: 1822775 1822776 1822777 AGE DAYS: 28 28 28 DATE TEST: 05/13/2019 05/13/2019 05/13/2019 SIZE (in.): Height X Diameter 8.000 X4.005 8.000 X 4.005 8.000 X 4.000 AREA (in.A2): 12.60' 12.60 12.57 CRUSH LOAD (ibs.): 74570 73540 72540 COMPRESSIVE STRENGTH (psi.): 5920 5840 5770 HEIGHT -DIAMETER RATIO: CORRECTION FACTOR: CORRECTED STRENGTH (psi.): BREAK TYPE: IV IV' V C.T.M. USED: Forney96 Forney96 Forney96 REMARKS: ASTM C39, C174, 0192, 'C470, C617, C42 COMPLIES: X DOES NOT COMPLY: FOR INFORMATION: THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC. SAMPLES CAST BY OTHERS: RESPECTFULLY SUBMITTED NOTICE:Thesetest results . are from samples cast by inspectors SOUTHWEST INSPECTION AND TESTING or technicians not employed: by our fine. They were eitherdelivered to our laboratory or,picked up by our driver. We will accept no responsibility forthe inspection made on the jobsite by the inspector, furthermore we ZAFAR AHME do not take responsibility for any information on this PRINCIPAL E ER report other than the strength: as tested .and reported. ASTM C39 BREAKS: 1=CONE - 11=CONE AND SPLIT - III=COLUMNAR - iV=SHEAR - V=SIDEFRACTURES - VI=POINTED Report of Special Inspection Project Name & Addresst '. Inspection Type(s) "ib"a Inspection Date(s) It " IJ'- l q ( ) Periodic [ Y ) Continuous List Tests Made: Total Inspection Time Each Day: List Items Requiring Correction, include uncorrected items previously listed Comments: To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. Signed: P `JI�Lr Lv Date l Print Full Name: Registration No, 400 ' COKHLTc FO.&ht S1-0?; 90 CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658 www.newoortbeachca.00v 1(949)644-3200 SPECIAL INSPECTION REPORT Project Address: Gray Residence. 301 Via Lido Soud, Newport Beach, CA Permit Number: S2018-0147 Inspection Type Inspection Date Concrete 2/26/19 Periodic Observed the placement and consolidation of 8 Cubic yards of concrete, mix design RS3001344, supplied by Robertsons and placed at footing for property line pool wall footing per detail 6/SP-A4. One set of 4 test samples was taken - ticket # 3619439, slump 5", PSI 3000, concrete temp 50F. Apollo Inspection Service. Castle Masonry. Total Inspection Time Each Day: Date_- --2/26/19__ Hours: + Min List All Items Requiring Correction (Include Previously Listed Uncorrected Items): Comments; Other than any noted discrepancies all work was done per approved plans, job site specifications, applicable codes, RFPs and WPS's to the best of my knowledge and appeared to be in compliance at time of inspection. Special Inspector Signature: Date: 2/26/19 Print Full Name: i Newport Beach Registration No.: . Peter Gilpin NB -0381 SpeciallnspectionReport 8-24-15 Continuous Inspection t%, Testing SOUTH STs s ® AL =1� AL '1W 1W It lrispectwn & Testirig, 11ic. 441 Commercial Way, La Habra, CA 90631-6168 (562)941-2990 - (714)526-8441 FAX (562)946-0026 FIELD DATA ON TEST SPECIMENS --- ASTM C31; C138, C143, C172, C173, C231, C1064 --- CONCRETE: MORTAR: SHOTCRETE: X CORES: GUNITE: ADDRESS: 301 VIA LIDO SOLID, NEWPORT BEACH JOB #: DATE: 05/16/2019 JOB NAME: FEUERSTEIN PERMIT #: S2018-0147 ISSUED BY: ARCHITECT': ENGINEER: FERRELL CONTRACTOR: INFINITY POOLS SUB: GOLD COAST SHOTCRETE LOCATION IN STRUCTURE: FLOOR OF THE POOL 1822775 TRACT: PHASE: LOT M CONCRETE SUPPLIER: NATIONAL RDY MX PLANT: MIX #: 71/2 -1 TYPE OF CEMENT: V ADMIXTURE: TICKET M 308955 SLUMP: 0.00 in. WATER ADDED: 0 gal. AIR TEMP: 0 F CONCRETE TEMP: MIXING TIME: TIME CAST: 12:00 DATE CAST: 04/15/2019 RECEIVED AT LAB: 04/25/2019 SPECIMENS MADE BY: KELLY LUIZ SPECIFIED PSI @ 28 Days: 4500 LAB #: 140813 CLIENT: RICHARD LUIZ TESTING INFORMATION SAMPLE IDENTIFICATION: 1822775 1822776 1822777 AGE DAYS: 28 28 28 DATE TEST: 05/13/2019 0511'3/2019 05/13/2019 SIZE (in.): Height X Diameter 8.000 X 4.005 8.000 X 4.005 8.000 X 4.000 AREA (in.A2): 12.60 12.60 12.57 CRUSH LOAD (lbs.): 74570 73540 72540 COMPRESSIVE STRENGTH (psi.): 5920 5840 5770 HEIGHT -DIAMETER RATIO: CORRECTION FACTOR: CORRECTED STRENGTH (psi.): BREAK TYPE: 1V IV V' C.T.M. USED: Forney96 Forney96 Forney96 REMARKS: COMPLIES: X ASTM C39, C174, C192, C470, 'C617, C42 DOES NOT COMPLY: FOR INFORMATION: THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC. SAMPLES CAST BY OTHERS: RESPECTFULLY SUBMITTED NOTICE:These test results are from samples cast by inspectors SOUTHWEST INSPECTION AND TESTING or technicians not employed by our firm. They were either delivered toour laboratory' or picked up by our driver. We will accept no responsibility forthe inspection made on the lobsite by the inspector, furthermore we ZAFAR AHME do not take responsibility for any information on this PRINCIPAL ER report other than the strength as tested and reported. ASTM C39 BREAKS: [=CONE - 11=CONEAND.SPLIT - 111=COLUMNAR. - IV=SHEAR' - V=SIDE FRACTURES - VI=POINTED Report of Special Inspection Project Name & Address J'eu�14' ' Sol kt�- &,' inspection Type(s) � Inspection Date(s) Periodic [ ] Continuous Total Inspection Time Each Day; List Items Requiring Correction, include uncorrected items previously listed Comments: X,"' To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. Signed: Date"lam j Print Full Name: Registration No, if"4 0 - CONCR=TE FORM S"2i9-