HomeMy WebLinkAboutX2020-1059 - Calcs0775 - ?.CDzX-) X2020 -105q II00 VO 95004 19A E S I / F M E I N C a STRUCTURAL ENGINEERS Fa- Retaining a Retaining Wall to be built at 1100 West Balboa Blvd, Newport Beach, CA April 22, 2020 IBC 2018, CBC 2019 Client: Valley Masonry BUILDING DIVISION APR P 9 2020 Client Job No. 19 No. L135 1800 E. 16th Street, Unit B, Santa Ana, CA 92701 Tel: (714) 835-2800 Fax: (714) 835-2819 Page: 2 ESIPME INC Date: 4/22/2020 STRUCTURAL ENGINEERS Job No: L135 Client: Valley Masonry Project Name: Retaining Wall Plan No: Load Conditions Seismic Design Summary Analysis Used: Equivalent Lateral Force Procedure (12.8) Roof (psf) Floor (psf) W/o LW 1.5" LW Ss = 1.391 Si = 0.494 Soil Site Class = D I = 1.0 R = 6.5 Comp. Tile Deck Conc. Conc. Or l" Gyperete F, = 1.2 F, = 1.5 Seismic Design Catergory D p = 1.0 n = 2.5 Stns = 1.669 Snu = 0.741 So, = 1.113 Sot = 0.494 Base shear = Live Load Dead Load Sheathing Wind Design Summary Rafter/Joists Wind Velocity = 100 M.P.H. Wind Exposure = C Sprinklers Ceiling Joists Governing Codes Drywall IBC 2018 ASCE7 2016 NDS 2018 TMS 402 2016 CBC 2019 AC13182014 SDPW52015 AISC360-10 is./Solar PVI Total(DL) oW(DL+LL) Proiectlnfo Soils Report Initials Date Address Engineer of Record: DF 4/22/2020 Street 1100 West Balboa Blvd By: CBC Job No: Project Engineer: EW 4/22/2020 City Newport Beach Date: Back Check: State, Zip Allowable Soil Bearing Pressure 1500 psf Roof Truss Review: For Addition] Information Refer to CBC Floor Truss Review: PT Foundation Review: Plan Check 1: Structural Observation/SpecialInspection Structural Observation Required: yes Special Inspection Required: yes Plan Check 2: Revisions Table of Contents Revision Revised Sheets Initials Date Description Pg. No. Notes 2-5 Retaining Wall 6-9 ESI/PME, Inc. - Structural Engineers (This Signature is to be a wet signature, not a copy.) QttiOFESSfON v O C40 r m I l v li fy�a\P lF OF CAI�Fo Date: LESI/FME INC UCTURAL ENGINEERS Project Name: Retaining Wall SPECIFICATION FOR RETAINING WALLS Page: 3 Date: 4/22/2020 Job No: L135 Client: Valley Masonry Plan No: 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON JOB. 2. TYPE OF SOIL AND BEARING VALUE SUBJECT TO BUILDING INSPECTOR APPROVAL. 3. ALLOWABLE BEARING VALUE 2000 PSF. MAXIMUM TOE PRESSURE IS 3000 PSF. 4. EXTENDED ALL FOOTINGS 18" MINIMUM BELOW UNDISTURBED NATURAL SOIL. 5. CONCRETE BLOCKS USED FOR THE CONSTRUCTION OF RETAINING WALLS SHALL BE NORMAL WEIGHT UNITS AND SHALL CONFORM TO THE REQUIREMENTS FOR GRADE N.I UNITS OF ASTM SPECIFICATIONS C-90 (LATEST REVISION). 6. TYPE "S" MORTAR: 1 PART CEMENT, 4 1/2 PARTS SAND, 1/2 PART LIME PUTTY. 7. GROUT SHALL BE ACCORDING TO CBC TABLE 21 -B f 2000 PSI MIN. 8. REINFORCING SHALL BE INTERMEDIATE GRADE DEFORMED BARS SHALL CONFORM TO ASTM SPECIFICATION A-305 (LATEST REVISION) AND A A-615 (LATEST REVISION). 9, ALL REINFORCING STEEL TO LAP WHERE SPLICED 40 DIAMETERS WITH A MINIMUM LAP OF 24". 10. REINFORCING BARS SHALL BE SET STRAIGHT AND SECURED ACCURATELY IN POSITION. 11. VERTICAL MORTAR JOINTS SHALL BE STAGGERED AND CENTERED ON BLOCKS OF EACH COURSE DIRECTLY BELOW. ALL CELLS SI BE VERTICALLY ALIGNED SO AS TO MAINTAIN A 5" x 5" MINIMUM CONCRETE VERTICAL STUD, ALIGNED SO AS TO MAINTAIN (4 X 8 1/2" FOR 12" CONCRETE BLOCKS). 12. CALL BUILDING DEPARTMENT FOR INSPECTIONS BEFORE POURING FOOTINGS AND AGAIN BEFORE FILLING CELLS WITH CONCRETE. 13. UNLESS OTHERWISE SPECIFIED, NO CONTINUOUS INSPECTION IS REQUIRED. 14. CELL WALLS AND CROSS WEBS WHICH FORM CELLS TO BE FILLED SHALL BE FULL BEDDED IN MORTAR TO PREVENT LEAKAGE OF CONCRETE, AND ALL ALIGNED SO AS TO MAINTAIN JOINTS AROUND SUCH CELLS SHALL BE STRUCK SMOOTH. 15. CELLS SHALL BE FILLED WITH CONCRETE IN LIFTS NOT TO EXCEED A HEIGHT OF 4'-0". IF OVER 4'-0" PROVIDE CLEANOUT HOLES AT BOTTOM OF EACH CELL AND EACH LIFT OF CONCRETE. ALL MORTAR CROPPINGS OR DEBRIS SHALL BE REMOVED FROM CELLS AND CLEANOUT HOLES SHALL BE SEALED BEFORE CONCRETE IS PLACED. 16. IMPERFECT JOINTING AND WALL SURFACES EXHIBITING DEFECTIVE BLOCKS WILL BE REJECTED AND MUST BE REPLACED AT NO COST TO THE OWNER. 17. RETAINING WALLS ARE NOT DESIGNED FOR SURCHARGE OF PAVING EQUIPMENT. EQUIPMENT SHOULD BE KEPT BACK FROM TOP OF WALL A MINIMUM DISTANCE EQUAL TO HEIGHT OF WALL ABOVE FOOTINGS. 18. BACKFILLING SHALL NOT BE STARTED FOR AT LEAST 14 DAYS AFTER THE FILLING OF THE CELLS WITH CONCRETE. 19. DIMENSIONS AND NOTATIONS SUPERCEDE SCALE OF DRAWINGS. 20. FOR WALLS WHERE CONCRETE SLAB IS USED TO SECURE TOP OF WALL, ADEQUATE TEMPORARY SHORING SHOULD BE PROVIDED PRIOR TO BACK FILLINGS. 21. PROVIDE 4" x 4" MIN. KEY AT BOTTOM OF WALL INTO FOOTING. UNLESS SLAB PROVIDED AT LOW END OF WALL. ESI/FME INC STRUCTURAL ENGINEERS Project Name: Retaining Wall Page: 4 Date: 4/22/2020 Job No: L135 Client: Valley Masonry Plan No: MASONRY 1. ALL MASONRY WORK SHALL CONFORM TO THE LATEST EDITION THE CALIFORNIA BUILDING CODE. 2. CONCRETE BLOCK SHALL BE OF SIZES SHOWN ON ARCHITECTURAL DRAWINGS AND/OR CALLED FOR IN SPECS. AND CONFORM TO ASTM C90-05, GRADE "A" NORMALWEIGHT UNITS WITH MAXIMUM LINEAR SHRINKAGE OF 0.06 %%% Pm = 1500 PSI GROUTED REINFORCED C 3. MORTAR MIX SHALL CONSIST OF ONE PART PORTLAND CEMENT, VOLUME OF SAND NOT LESS THAT 2-1/2 AND NOT MORE THAN 3 TIMES OF THE VOLUMES OF CEMENT AND LIME USED, AND 1/4 TO 1/2 PART HYDRATED LIME OR LIME PUTTY. MINIMUM COMPRESSIVE STRENG MORTAR TO BE Pm=1800 PSI. 4. GROUT SHALL CONSIST OF ONE PART PORMAND CEMENT, 3 PARTS SAND AND 2 PARTS PEA GRAVEL. COMPRESSIVE STRENGTH OF GROUT NOT BE LESS THAN Pg = 2000 PSI. 5. PROVIDE CLEANOUT OPENINGS AT BOTTOM OF ALL VERTICALLY GROUTED CELLS IF GROUT LIFT EXCEEDS 4'-0'. 6. ALL REINFORCING SHALL HAVE A MINIMUM COVERAGE OF 1/2" GROUT. 7. BOLTS SHALL BE GROUTED WITH 1" OF GROUT BETWEEN BOLT AND MASONRY. 8. NO PIPES OR DUCTS SHALL BE PLACED IN MASONRY WALLS UNLESS SPECIFICALLY NOTED OR DETAILED. 9. DOWELS IN CONCRETE FOR MASONRY WALLS SHALL BE THE SAME SIZE AND SPACING AS MASONRY WALL REINFORCING. 10, ALL MASONRY, EXCEPT VENEER, SHALL BE REINFORCED GROUTED MASONRY, GROUT CELLS CONTAINING REINFORCING UNLESS NOTED OTHERWISE. GROUT SOLID ALL MASONRY RETAINING EARTH UP TO 6 in. ABOVE RETAINING WALL. 11. ALL VERTICAL REINFORCING IN MASONRY WALLS NOT RETAINING EARTH SHALL BE LOCATED IN THE CENTER OF THE WALL, U.N.O. 12. REINFORCING SHALL BE SECURELY HELD AND BRACED IN PLACE TO PREVENT MOVEMENT WHILE PLACING MASONRY. 13. THE MINIMUM QUALTIY ASSURANCE PROGRAM FOR MASONRY IN NON-ESSENTIAL FACILATIES SHALL COMPLY WITH TABLE 1.18.2 OF TM 402-08/ACI 530-08/ASCE 5-08. THE MINIMUM QUALITY ASSURANCE PROGRAM FOR MASONRY IN ESSENTIAL FACILITIES SHALL COMPLY V TABLE 1. 18.3 OF TMS 402-OB/ACI530-08/ASCE 5-08. CONCRETE 1. ALL CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE CALIFORNIA BUILDING CODE. 2. CONCRETE SHALL BE DESIGNED AND TESTED AS OUTLINED IN THE SPECS. 3. ALL CEMENT SHALL CONFORM TO ASTM C-150. PLEASE CROSS-REFERENCE EXPOSURE CLASS SHOWN BELOW WITH CORROSION TABLE FC CONCRETE REQUIREMENTS. 4. FINE AND COARSE AGGREGATE SHALL CONFORM TO ASTM C-33 FOR STANDARD WEIGHT CONCRETE AND ASTM C-330 FOR LIGHT WEIGHT CONCRETE. S. ALL AGGREGATE SHALL BE COMPARABLE TO "SAN GABRIEL VALLEY" AGGREGATE. THE SHRINKAGE SHALL BE AS PER ASTM C-157 WITH TF AVERAGE DRYING SHRINKAGE AT 28 -DAYS NOT EXCEEDING 0.04%. 6. DRYPACK SHALL BE COMPOSED OF ONE PART PORTLAND CEMENT TO NOT MORE THAN THREE PARTS SAND. 7. ANCHOR BOLTS, HOLDOWN BOLTS, DOWELS, INSERTS, ETC. SHALL BE SECURELY TIED IN PLACE PRIOR TO POURING CONCRETE. 8. CONCRETE SHALL BE CURED BY KEEPING CONTINUOUSLY WET FOR 10 -DAYS OR BY AN APPROVED CURING COMPOUND. 9. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR MISCELLANEOUS ITEMS TO BE CAST INTO CONCf FLOOR DEPRESSIONS, PITS, ETC. 10. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF EXPANSION JOINTS, SCORING, ETC. FOR CONCRETE WALKS AND SLABS. 11. ALL CONCRETE, TYPE V PC = 2,500 PSI ALL CONCRETE SHALL REACH MINIMUM COMPRESSIVE STRENGTH 28 - DAYS. 12. ALL CONCRETE WITH PC GREATER THAN 2,500 PSI SHALL HAVE SPECIAL INSPECTION PER SECTION 1704 OF THE 2016 CBC UNLESS NO" OTHERWISE. 13. CONCRETE FOR SLAB ON GRADE SHALL HAVE A MAXIMUM OF 5 in. OF SLUMP PER ASTM C-143. 5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE. CEMENT ASTM C-150 TYPE 1 OR 2 MIN. ESI/FME INC STRUCTURAL ENGINEERS Project Name: Retaining Wall Page: 5 Date: 4/22/2020 Job No: L135 Client: Valley Masonry Plan No: Reinforcing Steel 1. ALL REINFORCING SHALL BE ASTM A-615 GRADE 40 FOR #4 BARS AND SMALLER. ALL REINFORCING SHALL BE ASTM A- 615 GRADE 60 FOR #5 BARS AND LARGER. WELDED WIRE FABRIC TO BE ASTM A-185, LAP 1-1/2 SPACES, 9" MIN. FOR STRUCTURAL SLABS ALL REINFORCING #5 AND LARGER TO BE ASTM A-615 GRADE 60. 2. ALL BARS SHALL BE DEFORMED AS PER ASTM A615 / A615M. 3. SPLICING OF #345 BARS SHALL HAVE A MIN. LAPPING OF 42 DIA. OR 32" MIN., WHICH EVER IS GREATER, IN ALL CONTINUOUS REINFORCEMENT OF FOOTINGS AND CONCRETE WALLS, EXCEPT AS NOTED ON PLANS. MASONRY REINFORCEMENT SHALL HAVE LAPPINGS OF 40 DIA. FOR GRADE 40 & 48 DIA. FOR GRADE 60 MIN. OR 2'-01, WHICH EVER IS GREATER. 4. ALL BENDS SHALL BE MADE COLD. S. SPLICING OF 14345 BARS SHALL HAVE A MIN. LAPPING OF 42 DIA. OR 32" MIN., WHICH EVER IS GREATER, IN ALL CONTINUOUS REINFORCEMENT OF FOOTINGS AND CONCRETE WALLS, EXCEPT AS NOTED ON PLANS. MASONRY REINFORCEMENT SHALL HAVE LAPPINGS OF 40 DIA. FOR GRADE 40 & 48 DIA. FOR GRADE 60 MIN. OR 2'-0", WHICH EVER IS GREATER. 6. ALL REINFORCING BARS SHALL BE ACCURATELY AND SECURELY PLACED BEFORE POURING CONCRETE. 7. CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AT LEAST EQUAL TO THE DIAMETER OF THE BARS. COVER SHALL BE AS FOLLOW: CONCRETE MASONRY A. POURED AGAINST EARTH ' B. POURED AGAINST FORM BELOW GRADE #6 AND LARGER ............... 2" 2" #5 AND SMALLER .............. 11/2" 11/2" C. FORMED SLABS .................... 1" 1" D. SLABS ON GRADE (FROM TOP OF SLAB) ..... 1" V. E. COLUMNS AND BEAMS TO MAIN BARS ..... 11/2" 2" F. WALLS - EXPOSED TO WEATHER ......... 11/2" 11/2" NOT EXPOSED TO WEATHER #11 AND SMALLER .............. 3/4" 3/4" #14 AND #18 ................. 11/2" 11/2" # OSS PD -.-„ - 4/2212020,11:20:34 AM Dale null -See Section 11.4.8 ASCE7-16 Design Code Reference Document II 'I Risk Category D - Default (See Section 11.4.3) Site class Fv Type Value Description MCER ground motion. (for 0.2 second period) Ss 1.391 PGA 0.61 MCER ground motion. (for 1.Os period) St 0.494. FpOA 1.2 Site -modified spectral acceleration value SMS 1.669 PGAM 0.731 Site -modified spectral acceleration value SM1 null -See Section 11.4.8 Probabilistic risk -targeted ground motion. (0.2 second) Numeric seismic design value at 0.2 second SA SDs 1Al2 Ss UH 1.537 Numeric seismic design value at 1.0 second SA SDI null -See Section 11.4.8 SO Type Value Description SDC null -See Section 11.4.8 Seismic design category ''. Site amplification factor at 0.2 second Fe 1.2 Fv null -See Section 11.4.8 Site amplification factor at 1.0 second MCEO peak ground acceleration PGA 0.61 Site amplification factor at PGA FpOA 1.2 Site modified peakgrcund acceleration PGAM 0.731 TL 8 Long -period transition period in seconds Probabilistic risk -targeted ground motion. (0.2 second) SSRT 1.391 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration Ss UH 1.537 Factored deterministic acceleration value. (0.2 second) SO 2.62 Probabilistic risk -targeted ground motion. (1.0 second) SIFT 0.494 -hazard (2% probability of exceedance in 50 years) spectral acceleration. S1UH 0.538 Factored uniform Factored deterministic acceleration value. (1.0 second) S1 D 0.822 Factored deterministic acceleration value. (Peak Ground Acceleration) PGAd 1.056 � I = ESI/ -IM E INC TRUCTURAL ENGINEER Project Name: F=23 PSF Page: Date: 4/22/2020 Job No: L135 Client: Valley Masonry Plan No: GOVERNINGLOA WIND ANALYSIS SEISMICANALYSIS F = q:GCf .4apSDe F=� W WIND qi=.00256KiKnKoV Rpflp F = 23 PSF K,=0.85 (TABLE 27.31) ap = 1.0 * Refer to Retain Pro output Rp=2.5 for wall &footing design Kr=1.0 (zs.e) KD=0.65 (TABLE28.1) SD:=1.113 I =1.0 V =110 MPH W =84 PSF G =0.65 (28.9) F=0.178 W Cr=1.30 (FIG 29.61) F=15 PSF F=23 PSF Page: Date: 4/22/2020 Job No: L135 Client: Valley Masonry Plan No: ESI/FME Inc. Structural Engineers 1800 E 16th Street, Unit B Santa Ana, CA 92701 (714)835-2800 This Wall In File: N:\ENG\Files\L135\L135.RPX Retained Height = 1.00 It Wall height above soil = 6.00 it Slope Behind Wall = 0.00 Height of Soil over Toe = 0.00 in Water height over heel = 0.0 ft Surcharge Loads 1 Allow Soil Bearing Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psi Used for Sliding & Overturning Soil Density, Heel Axial Load Applied to Stem Soil Density, Toe Axial Dead Load = 0.0 Itis Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Desi n Summa Allowable = 75.0 psi Wall Stability Ratios 6.00 Overturning = 1.82 OK Sliding = 1.87 OK Title Retaining Wall Page: 1 Job#: Dsgnr: EW Date: 27 JAN 2020 Description.... Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16 Soil Data 1 Allow Soil Bearing = 1,995.0 psi Equivalent Fluid Pressure Method Active Heel Pressure = 32.0 psf/ft Passive Pressure = 250.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingliSoil Friction = 0.300 Soil height to Ignore = 12.00 In for passive pressure 1.2 psi OK Lateral Load Applied to Stem Lateral Load= 23.0 #/it ...Height to Top = 7.33 ft ...Height to Bottom = 1.33 it Load Type = Wind (W) 1,995 psf (Strength Level) Total Bearing Load = 916 lbs ...resultant ecc. = 9.83 in Soil Pressure @ Toe = 1,416 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 1,995 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,982 psi ACI Factored @ Heel = 0 psi Footing Shear @ Toe = 7.5 psi OK Footing Shear @ Heel = 1.2 psi OK Allowable = 75.0 psi Sliding Calcs 6.00 Lateral Sliding Force = 146.8 lbs less 100% Passive Force = - 0.0 lbs less 100% Friction Force = - 274.8 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 Stability = 0.0 lbs OK Wind on Exposed Stem = 0.0 psf (Strength Level) Adjacent Footing Load Adjacent Footing Load = 0.0 lbs Footing vviom - Eccentricity = '. 11 0.00 in Wall to Fig CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil = 0.0 ft at Back of Wall ft= Poisson's Ratio = 0.300 Stem Construction CBC 2019,ACI 2nd Bottom Live Load 1.600 Stem OK Stem OK Design Height Above Ftc ft= 1.33 0.00 Wall Material Above W' = Maonry Masonry Design Method = ASD ASD LRFD Thickness = 6.00 6.00 Rebar Size = # 4 # 4 Rebar Spacing = 24.00 24.00 Rebar Placed at = Center Center Design Data 0.502 0.735 fb/FB+fa/Fa = Total Force @ Section Service Level lbs= 82.8 98.8 Strength Level lbs= Moment.... Actual Service Level ft-#= 248.4 363.9 Strength Level ft-#= Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Moment..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Rebar Depth 'd' Masonry Data I'm Fs Solid Grouting Modular Ratio'n' Wall Weight Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data rc Fy ft-# = 494.7 psi= 3.5 psi= psi = 45.1 in2= 23.38 in = 2.75 494.7 1.5 45.0 67.50 2.75 psi= 1,500 1,500 psi= 24,000 24,000 = No Yes = 21.48 21.48 psf= 43.0 58.0 = 1.000 1.000 in= 4.10 5.60 = Medium Weight = ASD psi = psi = ESIIFME Inc. Title Retairfing Wall Page: 2 Structural Engineers Job #: Dsgnr: EW Date: 27 JAN 2020 1800 E 16th Street, Unit B Description.... Santa Ana, CA 92701 (714)835-2800 This Wall in File: N:\ENG\Files\L135\L135.RPX RetainPro (c)1987.2018, Build 11.18.06.15 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16 . kwrRns,n,4 g Footing Dimensions & Strengths ` Footing Design Results Toe Width = 0.00 ft Toe Heel Heel Width = 2.50 Factored Pressure = 1,982 0 psi Total Footing Width = 2.50 Mu': Upward = 0 128 it-# Fooling Thickness = 12.00 in Mu': Downward = 0 702 ft-# Mu: Design = 0 574 ft-# Key Width = 12.00 in Actual 1 -Way Shear = 7.51 1.18 psi Key Depth = 0.00 in Allow 1 -Way Shear = 40.00 40.00 psi Key Distance from Toe = 2.00 it Toe Reinforcing = None Spedd fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spedd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spedd Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm. 3.00 in Toe: Not rsq'd: Mu < phi*5*lambda*sgrt(fc)*Sm Heel: Not req'd: Mu < phi*5*lambda*sgrt(fc)*Sm Key: Not req'd: Mu < phi*5*lambda*sgrt(fc)*Sm Min footing T&S reinf Area 0.65 in2 Min footing T&S reinf Area per foot 0.26 in2 /ft If one layer of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 In #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... Force Distance .....RESISTING..... Moment Force Distance Moment Item be It ft-# lbs it ft# Heel Active Pressure = 64.0 0.67 42.7 Soil Over Heel = 220.0 1.50 330.0 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = 82.8 5.33 441.3 Axial Dead Load on Stem = Load @ Stem Above Soil = * Axial Live Load on Stem = = Soil Over Toe = Surcharge Over Toe = Stem Welght(s) = 321.0 0.25 80.2 Total 146.8 O.T.M. 484.0 Earth @ Stem Transitions= _ = Footing Weight = 375.0 1.25 468.8 Resisting/Overturning Ratio = 1.82 Key Weight = 2.50 Vertical Loads used for Soil Pressure = 916.0 lbs Vert. Component = 2.50 Total = 916.0 lbs R.M = 879.0 * Axial live load NOT Included in total displayed or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Dell @ Top of Wall (approximate only) 0.110 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe because the wall would then tend to rotate into the retained soil. 0775 - ZoZc) E S I / F M E INC. STRUCTURAL ENGINEERS Retaining Wall to be built at 1100 West Balboa Blvd, Newport Beach, CA April 22, 2020 lRevision IBC 2018, CBC 2019 Valley Masonif UILDING DIVISION Job No. No. L135 A P A 2 9 2020 1800 E. 16th Street, Unit B, Santa Ana, CA 92701 Tel: (714) 835-2800 Fax: (714) 835-2819 Page: 2 ESI/FME INC Date: 4/22/2020 STRUCTURAL ENGINEERS Job No: L135 Client: Valley Masonry Project Name: Retaining Wall Plan No: Load Conditions Seismic Design Summary Analysis Used: Equivalent lateral Force Procedure (12.8) Floor (psf) ffRoOl'Psf) Deck w/o LW Conc. 1.5 Lvv Conc. Or Gyperete Ss = 1.391 St = 0.494 Soil Site Class = D I = 1.0 R = 6.5 F, = 1.2 F„ = 1.5 Seismic Design Catergory = D p = 1.0 R = 2.5 Live Load SMs= 1.669 SM,= 0.741 Dead Load So, = 1.113 So, = 0.494 Base Shear = - Sheathing Wind Design Summary Raker/Joists Wind Velocity = 100 M.P.H. Wind Exposure = C Sprinklers Ceiling Joists Governing Codes Drywan IBC 2018 ASCE72016 NDS 2018 TMS 4022016 Is./Solar PV Total (DL) CBC 2019 AC13182014 SDPWS 2015 AISC360-10 Total (DL+LL) Project Info Soils Report Initials Date Address Engineer of Record: OF 4/22/2020 Street 1100 West Balboa Blvd By: CBC Job No: Project Engineer: EW 4/22/2020 City Newport Beach Date: Back Check: State, Zip Allowable Soil Bearing Pressure 1500 psf Roof Truss Review: For Additioni Information Refer to CBC Floor Truss Review: PT Foundation Review: Plan Check 1: Structural Observation/Special Inspection Structural Observation Required: Yes Special Inspection Required: Yes Plan Check 2: Revisions Table of Contents Revision Revised Sheets Initials Date Description Pg. No. Notes 2-5 Retaining Wall 6-9 ESI/FME, Inc. - Structural Engineers (This Signature is to be a wet signature, not a copy.) Q<lOFESS/ON q�F v K C /0 v m lF OF CAUFO� `{�Z`f�ZOZO Date: ESI/FME INC STRUCTURAL ENGINEERS Project Name: Retaining Wall Page: 4 Date:4/22/2020 Job No: L135 Client: Valley Masonry Plan No: MASONRY 1. ALL MASONRY WORK SHALL CONFORM TO THE LATEST EDITION THE CALIFORNIA BUILDING CODE. 2. CONCRETE BLOCK SHALL BE OF SIZES SHOWN ON ARCHITECTURAL DRAWINGS AND/OR CALLED FOR IN SPECS. AND CONFORM TO ASTM C90-05, GRADE "A" NORMALWEIGHT UNITS WITH MAXIMUM LINEAR SHRINKAGE OF 0.06 %%% Pm = 1500 PSI GROUTED REINFORCED C 3. MORTAR MIX SHALL CONSIST OF ONE PART PORTLAND CEMENT, VOLUME OF SAND NOT LESS THAT 2-1/2 AND NOT MORE THAN 3 TIMES OF THE VOLUMES OF CEMENT AND LIME USED, AND 1/4 TO 1/2 PART HYDRATED LIME OR LIME PUTTY. MINIMUM COMPRESSIVE STRENG MORTAR TO BE Pm=1800 PSI. 4. GROUT SHALL CONSIST OF ONE PART PORTLAND CEMENT, 3 PARTS SAND AND 2 PARTS PEA GRAVEL. COMPRESSIVE STRENGTH OF GROUI NOT BE LESS THAN Pg = 2000 PSI. S. PROVIDE CLEANOUT OPENINGS AT BOTTOM OF ALL VERTICALLY GROUTED CELLS IF GROUT LIFT EXCEEDS 4'-0'. 6. ALL REINFORCING SHALL HAVE A MINIMUM COVERAGE OF 1/2" GROUT. 7. BOLTS SHALL BE GROUTED WITH 1" OF GROUT BETWEEN BOLT AND MASONRY. B. NO PIPES OR DUCTS SHALL BE PLACED IN MASONRY WALLS UNLESS SPECIFICALLY NOTED OR DETAILED. 9. DOWELS IN CONCRETE FOR MASONRY WALLS SHALL BE THE SAME SIZE AND SPACING AS MASONRY WALL REINFORCING. 10. ALL MASONRY, EXCEPT VENEER, SHALL BE REINFORCED GROUTED MASONRY, GROUT CELLS CONTAINING REINFORCING UNLESS NOTED OTHERWISE. GROUT SOLID ALL MASONRY RETAINING EARTH UP TO 6 In. ABOVE RETAINING WALL. 11. ALL VERTICAL REINFORCING IN MASONRY WALLS NOT RETAINING EARTH SHALL BE LOCATED IN THE CENTER OF THE WALL, U.N.O. 12. REINFORCING SHALL BE SECURELY HELD AND BRACED IN PLACE TO PREVENT MOVEMENT WHILE PLACING MASONRY. 13. THE MINIMUM QUALTIY ASSURANCE PROGRAM FOR MASONRY IN NON-ESSENTIAL FACILATIES SHALL COMPLY WITH TABLE 1.18.2 OF TM 402-08/ACI 530-08/ASCE 5-08. THE MINIMUM QUALTIY ASSURANCE PROGRAM FOR MASONRY IN ESSENTIAL FACILITIES SHALL COMPLY V TABLE 1. 183 OF TMS 402-08/ACI530-08/ASCE 5-08. CONCRETE 1. ALL CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE CALIFORNIA BUILDING CODE, 2. CONCRETE SHALL BE DESIGNED AND TESTED AS OUTLINED IN THE SPECS, 3. ALL CEMENT SHALL CONFORM TO ASTM C-150. PLEASE CROSS-REFERENCE EXPOSURE CLASS SHOWN BELOW WITH CORROSION TABLE FC CONCRETE REQUIREMENTS. 4. FINE AND COARSE AGGREGATE SHALL CONFORM TO ASTM C-33 FOR STANDARD WEIGHT CONCRETE AND ASTM C-330 FOR LIGHT WEIGHT CONCRETE. 5. ALL AGGREGATE SHALL BE COMPARABLE TO "SAN GABRIEL VALLEY" AGGREGATE. THE SHRINKAGE SHALL BE AS PER ASTM C-157 WITH TF AVERAGE DRYING SHRINKAGE AT 28 -DAYS NOT EXCEEDING 0.04%. 6. DRYPACK SHALL BE COMPOSED OF ONE PART PORTLAND CEMENT TO NOT MORE THAN THREE PARTS SAND. 7. ANCHOR BOLTS, HOLDOWN BOLTS, DOWELS, INSERTS, ETC. SHALL BE SECURELY TIED IN PLACE PRIOR TO POURING CONCRETE. 8. CONCRETE SHALL BE CURED BY KEEPING CONTINUOUSLY WET FOR 10 -DAYS OR BY AN APPROVED CURING COMPOUND. 9. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR MISCELLANEOUS ITEMS TO BE CAST INTO CONCF FLOOR DEPRESSIONS, PITS, ETC. 10. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF EXPANSION JOINTS, SCORING, ETC. FOR CONCRETE WALKS AND SLABS. 11. ALL CONCRETE, TYPE V PC = 2,500 PSI ALL CONCRETE SHALL REACH MINIMUM COMPRESSIVE STRENGTH 28 - DAYS. 12. ALL CONCRETE WITH PC GREATER THAN 2,500 PSI SHALL HAVE SPECIAL INSPECTION PER SECTION 1704 OF THE 2016 CBC UNLESS NO' OTHERWISE. 13. CONCRETE FOR SLAB ON GRADE SHALL HAVE A MAXIMUM OF 5 In. OF SLUMP PER ASTM C-143. 5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE. CEMENT ASTM C-150 TYPE 1 OR 2 MIN. ESI/FME INC STRUCTURAL ENGINEERS Project Name: Retaining Wall Page: 5 Date: 4/22/2020 Job No: L135 Client: Valley Masonry Plan No: Reinforcing Steel 1. ALL REINFORCING SHALL BE ASTM A-615 GRADE 40 FOR #4 BARS AND SMALLER. ALL REINFORCING SHALL BE ASTM A- 615 GRADE 60 FOR #5 BARS AND LARGER. WELDED WIRE FABRIC TO BE ASTM A-185, LAP 1-1/2 SPACES, 9" MIN. FOR STRUCTURAL SLABS ALL REINFORCING #5 AND LARGER TO BE ASTM A-615 GRADE 60. 2. ALL BARS SHALL BE DEFORMED AS PER ASTM A615 / A615M. 3. SPLICING OF #345 BARS SHALL HAVE A MIN. LAPPING OF 42 DIA. OR 32" MIN., WHICH EVER IS GREATER, IN ALL CONTINUOUS REINFORCEMENT OF FOOTINGS AND CONCRETE WALLS, EXCEPT AS NOTED ON PLANS. MASONRY REINFORCEMENT SHALL HAVE LAPPINGS OF 40 DIA. FOR GRADE 40 & 48 DIA. FOR GRADE 60 MIN. OR 2'-0", WHICH EVER IS GREATER. 4. ALL BENDS SHALL BE MADE COLD. 5. SPLICING OF #345 BARS SHALL HAVE A MIN. LAPPING OF 42 DIA. OR 32" MIN., WHICH EVER IS GREATER, IN ALL CONTINUOUS REINFORCEMENT OF FOOTINGS AND CONCRETE WALLS, EXCEPT AS NOTED ON PLANS. MASONRY REINFORCEMENT SHALL HAVE LAPPINGS OF 40 DIA. FOR GRADE 40 & 48 DIA. FOR GRADE 60 MIN. OR 2'-0", WHICH EVER IS GREATER. 6. ALL REINFORCING BARS SHALL BE ACCURATELY AND SECURELY PLACED BEFORE POURING CONCRETE, 7, CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AT LEAST EQUAL TO THE DIAMETER OF THE BARS. COVER SHALL BE AS FOLLOW: CONCRETE MASONRY A. POURED AGAINST EARTH ............. 3" 2" B. POURED AGAINST FORM BELOW GRADE #6 AND LARGER ............... 2" 2" #5 AND SMALLER .............. 11/2" 11/2" C. FORMED SLABS .................... 1" 1" D. SLABS ON GRADE (FROM TOP OF SLAB) ..... 1" 1" E. COLUMNS AND BEAMS TO MAIN BARS ..... 11/2" 2" F. WALLS - EXPOSED TO WEATHER ......... 11/2" 11/2" NOT EXPOSED TO WEATHER #11 AND SMALLER .............. 3/4" 3/4" #14 AND #18 ................. 11/2" 11/2" ESI/FME INC 5 TRUCTURAL ENGINEER Client: Project Name: Retaining Wall Plan No: Page: Date: 4/22/2020 Job No: L135 Valley Masonry FREE STANDING WALL LATERAL ANALYSIS (ASC 40J WINDANALYSISSSEISMIC _ ANALYSIS GOVERNING LOA F=q:GCr WIND q,=.00256K�KnKDV F_.4apSDsW Rp/lp F = 23 PSF K,=0.86 (TABLE 27.61) ap = 1.0 • Refer to Retain Pro output Kr=1.0 (26.8) Rp=2.6 for wall&fooWg design KD=0.85 (TABLE26.1) SDs=1.113 1 =1.0 Ip=1.0 V =110 MPH W =84 PSF G=0.85 (28.9) F=0.178W Cr=1.30 (FIG 29.61) F=15 PSF F=23 PSF F= 23 PSF ESI/FME Inc. Structural Engineers 1800 E 16th Street, Unit B Santa Ana, CA 92701 (714)835-2800 This Wall in File: N:1ENG%Files1L1351L135.RPX Criteria 1,416 psf OK Retained Height = 1.00 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 0.00 in Water height over heel = 0.0 ft Surcharge Loads 1,416 psf OK Surcharge Over Heel - 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning 1,982 psf Axial Load Applied to Stem Axial Dead Load = 0.0 lbs Axial Live Load = 0.0 lbs Axial Load Eccentricity = 0.0 in Desi n Summary Sliding Calcs Wall Stability Ratios Lateral Sliding Force = Overturning = 1.82 OK Sliding = 1.87 OK Total Bearing Load = 916 lbs ...resultant see. = 9.83 in Soil Pressure @ Toe = 1,416 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 1.995 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,982 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 7.5 psi OK Footing Shear @ Heel = 1.2 psi OK Allowable = 75.0 psi Sliding Calcs # 4 Lateral Sliding Force = 146.8 lbs less 100% Passive Force = - 0.0 lbs less 100% Friction Force = - 274.8 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 Stability = 0.0 be OK Title Retai@Ing Wall Page: 1 Job # : Dsgnr: EW Date: 27 JAN 2020 Description.... Cantilevered Retaining Wall Soil Data Allow Soil Bearing = 1,995.0 psi Equivalent Fluid Pressure Method Active Heel Pressure = 32.0 psf/ft Passive Pressure 250.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingIlSoil Friction = 0.300 ., Soil height to ignore 0.00 it for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 23.0 #/ft ...Height to Top = 7.33 it ...Height to Bottom = 1.33 ft Load Type = Wind (W) 0.00 it (Strength Level) Wind on Exposed Stem = 0.0 psf (Strength Level) = at Back of Wall Code: CBC 2019,ACi 318-14,TMS 402-16 Adjacent Footing Load it= Adjacent Footing Load = 0.01b Footing Width = 0.00 It Eccentricity = 0.00 In Wall to Fig CL Dist = 0.00 it Footing Type Line Load Base Above/Below Soil = = at Back of Wall 0.0 ft Poisson's Ratio = 0.30D Stem Construction 2nd Bottom Stem OK Stem OK Design Height Above Fig it= 1.33 0.00 Wall Material Above "Hf' = Masonry Masonry Design Method = ASD ASD LRFD Thickness = 6.00 6.00 Rebar Size = # 4 # 4 Rebar Spacing = 24.00 24.00 Rebar Placed at = Center Center Design Data fc psi= fb/FB + fa/Fa = 0.502 0.735 Total Force @ Section Service Level lbs= 82.8 98.8 Strength Level lbs= Moment.... Actual Service Level ft-#= 248.4 363.9 Strength Level ft-#= Moment..... Allowable ft-#= 494.7 494.7 Shear..... Actual Service Level psi= 3.5 1.5 Strength Level psi= Shear..... Allowable psi= 45.1 45.0 Anet (Masonry) int = 23.38 67.50 Rebar Depth 'd' In= 2.75 2.75 Masonry Data Pm psi= 1,500 1,500 Fs psi = 24,000 24,000 Solid Grouting = No Yes Vertical component of active lateral soil pressure IS Modular Ratio'n' = 21.48 21.48 considered in the calculation of soil bearing pressures. Wall Weight psi= 43.0 58.0 Load Factors Short Term Factor = 1.000 1.000 Building Code CBC 2019,ACI Equiv, Solid Thick. in= 4.10 5.60 Dead Load 1.200 Masonry Block Type = Medium Weight Live Load 1.600 Masonry Design Method = ASD. Earth, H 1.600 Concrete Data Wind, W 1.000 fc psi= Seismic, E 1.000 Fy psi= ESI/FME Inc. Structural Engineers 1800 E 16th Street, Unit B Santa Ana, CA 92701 (714) 835-2800 This Wall in File: N:\ENG\Files\L1351L135.RPX Footing Dimensions &Strengths Toe Width = 0.00 ft Heel Width = 2.50 Total Footing Width = 2.50 Footing Thickness = 12.00 in Key Width = 12.00 in Key Depth = 0.00 In Key Distance from Toe = 2.00 ft fc = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm. 3.00 in Item Heel Active Pressure = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = Title Retaining Wall Page : 2 Job #: Dsgnr: EW Date: 27 JAN 2020 Description.... Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16 Footing Design Results III NNEENUMEMEMMOMM Toe Heel Factored Pressure = 1,982 0 psi Mu': Upward = 0 128 ft -A Mu': Downward = 0 702 ft4 Mu: Design = 0 574 ft-# Actual 1 -Way Shear = 7.51 1.18 psi Allow 1 -Way Shear = 40.00 40.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Other Acceptable Sizes & Spacings Toe: Not req'd: Mu <phi*5*lambda*sgrt(fc)*Sm Heel: Not req'd: Mu < phi*5*lambda*sgrt(fc)*Sm Key: Not req'd: Mu <phl*5*lambda*sgrt(fc)*Sm Min footing T&S reinf Area 0.65 in2 Min footing T&S reinf Area per foot 0.26 in2 ift If one layer of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18,52 in #5@ 14.35 In #5@ 28.70 in #6@ 20.371n #6@ 40.74 in Force Distance Moment lbs ft ft-# 64.0 0.67 42.7 82.6 5.33 441.3 Total 146.8 O.T.M. 484.0 Resisting/Overturning Ratio = 1.82 Vertical Loads used for Soil Pressure = 916.0 lbs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Ton of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Dell! @ Top of Wall (approximate only) 0.110 in The above calculation is not valid if the heel soil bearing Pressure exceeds that of the toe because the well would then tend to rotate into the retained soil .....RESISTING..... Force Distance Moment lbs It ft# Soil Over Heel = 220.0 1.50 330.0 Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = * Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = 321.0 0.25 80.2 Earth @ Stem Transitions= Footing Weight = 375.0 1.25 468.8 Key Weight = 2.50 Vert. Component = 2.50 Total = 916.0 lbs R.M.= 879.0 * Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Ton of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Dell! @ Top of Wall (approximate only) 0.110 in The above calculation is not valid if the heel soil bearing Pressure exceeds that of the toe because the well would then tend to rotate into the retained soil