Loading...
HomeMy WebLinkAboutF2021-0352 - MiscConcealed Quick Response Sprinkler Coverage to20'x20'(6.Omx6.0m) Features 1. Quick response performance. 2. Push on, thread off, sturdy convenient cover plate. 3. Factory assembled sprinkler and cup, shipped complete with protective cap. 4. Sprinkler assembly and cover plate separately packaged. 6. Rugged damage resistant assembly. No exposed thermal element. 7. Utilizes the Model F1FR QREC Pendent Sprinkler. 8. Aesthetic ceiling profile. 9. Standard finishes in white painted or chrome plated. Other color -painted and specialty finishes available. For Model F1 FR QREC CCP 1/2" K 5.6 (80) Sprinkler Types refer to Bulletin 028 for technical specifications and approvals. Product Description Model F1 FR QREC Quick Response Extended Coverage Concealed Sprinkler is an attractive, low profile concealed sprinkler assembly. This sprinkler assembly utilizes a Model F1 FR QREC pendent sprinkler in a Model CCP cup and push -on thread -off cover plate assembly. The cup is securely factory threaded on the sprinkler's inlet end. The assembly is shipped with a protective cap. The sprinkler and cup are easily installed into the sprinkler fitting using the Model GFR2 Sprinkler Wrench. The cover plate assembly is attached to the sprinkler cup using a flexible tooth threaded engagement. The cover plate is attached to the skirt using 135°F (57°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the �('� Bulletin 151 September p202�r 0 I v VL Model F1 FR QREC CCP Concealed Quick Response Extended Coverage Sprinkler cover plate melts, allowing the release of this part and thus exposing the Model F1 FR QREC sprinkler inside to the rising ambient temperature. The Temperature rating of the sprinkler identified by the color of the glass bulb. Model F1 FR QREC automatic sprinkler utilizes a 3.0 mm frangible glass bulb. This sprinkler has demonstrated response times in laboratory tests which are five times faster than standard response sprinklers. This quick response enables the Model F1 FR QREC sprinkler to apply water to a fire faster than standard sprinklers of the same temperature rating. Approval Type: Quick Response Extended Coverage — Light Hazard Technical Data: (1) 135°F (57°C) Only Note: 1 bar - 100 kPa The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Sprinkler Nominal ThreadApproval Ident. Orifice Size a Organizations Number (SIN) /� 17/32" (20mm) 3/a" (R3/a) cULus R4842 Thread Temp. Rating Max. Bulb SprinJ'Jer Size Model Color Tern P• 3/" NPT F1FR 135°5°F 100°F Orange (R3/) QREC 57°7°C38°Cg3/" NPT F1FR 155°F 100°FRed (R3/) QREC 687°C 38°C Coverage Area Pressure Flow Rate psi (bar) Max Enclosure Area Bpm (Urn) Width x Length K=8.0 ftxft (mxm) (Metric 115.3) 26 (98.4) 10.6 (0,7) 16 x 16 (4.9 x 4.9) 33(125.0) 17.0(1,2) 18x 18(5.5 x5.5) 40(151.4) 25.0(1,7) 20 x 200)(6.0 x 6.0)(1) (1) 135°F (57°C) Only Note: 1 bar - 100 kPa The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation Model F1 FR QREC Concealed Sprinklers use 135°F (57°C) or 155OF (68°C) Model F1 FR QREC Pendent Sprinklers with a threaded Model CCP cup which is factory attached to the sprinkler. The assembly is completed by the installation of the attractive, low profile, 135OF (57°C) rated cover plate assembly. The cover plate and sprinkler cup are joined using a flexible tooth threaded engagement. Do not install these sprinklers in ceilings which have positive pressure in the space above. The sprinkler cup is factory attached to the Model F1 FR QREC Sprinkler. A PTFE based thread sealant should be applied to the sprinkler threads only. After a 25A inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model GFR2 Wrench. When installing a sprinkler, the protective cap is removed and the wrench is positioned into the sprinkler/cup assembly until the two wrench faces engage the wrenching flats on the Model F1 FR QREC Sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate assembly is then pressed into the cup. Final adjustment is made by turning the cover plate until the skirt flange makes full contact with the ceiling surface. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1 FR QREC Pendent Sprinkler or the use of the Model CCP concealed cover plate assembly on any sprinkler with which it is not specifically listed may prevent good fire protection and will void all guarantees, warranties, listings and approvals. 1" x 3/4" REDUCING TEE OR ELeow A" [66 ]mm] ON. 2,y" (58, ]mmJ DNI — HOLE IN ..' RA ca IS" (Je imm] AIAx FACE OF F?ZINC rO FACE OF GELLLNG CAJENEION CIDUNG }" (127—' MAX.T covEre A1111o✓usmENr .1 PL1rE— ASSEM6LY 3Ij" ($3Hmm] SGRMKI£R COVER PLArE. 1/2(127mm7 AOJUSiMENi Maintenance Model F1 FR QREC Concealed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Approvals cULus (Sprinklers, Automatic and Open. Quick Response Extended Coverage Sprinklers) NYC MEA 258-93-E Ordering Information Specify:Sprinkler Model: 1.F1FR QREC Pendent 3/4" NPT or ISO 7-R3/4 threads 2. Sprinkler Temp. Rating0): 135GF(57°C)or 155-F (68-C). 3.Cover plate Model: CCP 4.Cover plate temp. rating: 135-F (57°C). 5.Cover plate finish: (1) 135°F (57°C) required for 20'x 20' (6.Om x 6.0m) coverage area Installation Wrench Model GFR2 Sprinkler Wrench Installation Aid A protective cap is included for use during installation. Cover Plate Finishes(n Standard Finishes Chrome White Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. Important: The F1 FR QREC Sprinkler with the Model CCP cover plate is not an FM Approved combination. The equipment presented in this bulletin is to be installed In accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ® Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 09/20 PM 99999/0148 Coverage to 18 ft. x 22 ft. (5.5m x 6.7m), 16 ft. x 24 ft. (4.9m x 7.3m). Features: 1. Flat cover plate. 2. K -factor of 8.0 (115 metric). 3. Listed as quick -response, extended coverage for Light Hazard occupancies. 4. Sprinkler assembly and cover plate packaged separately. 5. 1/4' (6.3mm) cover plate adjustment. 6. Model G6 Cover plate available in in a wide vari- ety of colors and finishes. Approval Organizations 1. Listed for use in Light Hazard occupancies by Underwriters Laboratories Inc. and UL certified for Canada (cULus). UL Listing Category Sprinklers, Automatic and Open Quick Response Extended Coverage Sprinklers Product Description The Reliable Model G6-80 Concealed Quick Response Extended Coverage Horizontal Sidewall Sprinkler is an at- tractive, concealed sprinkler assembly that utilizes a push- on/pull-off cover plate assembly. The sprinkler assembly is shipped with a protective cap. The flat cover plate is attached to the skirt using 135°F (57°C) ordinary temperature classification solder. The sprin- kler is installed into the sprinkler fitting using the Model G6 Sprinkler Wrench. When the ambient temperature rises, the solder holding the cover plate melts, allowing the release of this part and thus exposing the sprinkler inside to the rising ambient tem- �erature. he Model G6-80 utilizes a Quick Response soldered link. k -response sprinklers are designed to apply water to a )ner than standard -response sprinklers of the same lure rating. +el G6-80 sprinkler is listed for a maximum service 175 psi (12,0 bar). natic Sprinkler Co., Inc., 103 Bulletin 047 August 2019 Model G6-80 K8.0 (115 metric) Concealed Quick Response Extended Coverage Light Hazard Horizontal Sidewall Sprinkler (SIN RA4762) Application and Installation The Model G6-80 sprinkler is intended for installation in light hazard occupancies in accordance with NFPA 13. This sprinkler is especially well-suited for use in non -corrosive environments in student dormitories, hotels, hospitals and care facilities. Model G6-80 Concealed Horizontal Sidewall sprinklers utilize a sprinkler assembly with spring loaded deployable deflector feature. The assembly is completed by the instal- lation of the attractive, 135°F (57°C) push-on/pull-off cover plate assembly, which provides 1/4" (6.3mm) of adjustment. Apply a Teflon' - based thread sealant to the sprinkler threads. After a 2 5/e' (66.7mm) diameter hole is cut in the wall, the sprinkler is installed and properly oriented with the Model G6 Wrench, as follows: Do not remove factory installed plastic protective cap since it is sized to fit inside the G6 wrench. Note that the sprinkler can only mate when the sprinkler's deflector ori- entation tab (Fig. 1) is aligned with wrench's key -way. The G6 Wrench has a bubble level pad and TOP to assist the installer in properly orienting the sprinkler. Final leveling can be done after leak proof joint is obtained with a minimum to maximum torque of 14 to 20 ft -lbs (19 to 27 N m). Do not attempt to compensate for improper rough in dimensions of fitting by over tightening the sprinkler assembly, but readjust the sprinkler fitting instead. Leave the protective cap on to assure sprinkler protection while the wall is plastered, wall- papered or painted. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model G6-80 Horizontal Sidewall Sprinkler or the use of this dedicated concealed cover plate assembly on any sprinkler with which it is not specifically listed will void all guarantees, warranties, listings and approvals. DuPont Registered Trademark Fairview Park Drive, Elmsford, New York 10523 Technical Data: Nominal K -factor Thread Size Temperature Rating Maximum Ambient Temperature Maximum Water Working Pressure us Metric Sprinkler Cover 8.0 115 3/4" NPT or ISO 7-R3/a 165°F (74°C) 135°F Y00°F 175 PSI Coverage Area Max. Installed Coverage Area Width x Length Deflector to Ceiling Dimension Min. Required Flow Rate Min. Required Pressure ft. x ft. m x m inches mm gpm Umin psi bar 14x22 4.3x6.7 4-6 102-152 31 117.3 15.0 1,03 14x22 4.3x6.7 6-12 152-305 35 132.5 19.1 1,3 14x24 4.3x7.3 4-6 102-152 35 132.5 19.1 1,3 14 x 24 4.3 x 7.3 6-12 152 -305 39 147.6 23.8 1,6 16 x 16 4.9 x 4.9 4-12 102-305 26 98.4 10.6 0,7 16 x 18 4.9 x 5.5 4-12 102-305 29 109.8 13.1 0,9 16x20 4.9x6.1 4-12 102-305 32 121.1 16.0 1,1 16 x 22 4.9 x 6.7 4-12 102-305 36 136.2 20.2 1,4 16x24 4.9x7.3 4-12 102-305 39 147.6 23.8 1,6 18x18 5.5x5.5 4-12 102-305 33 124.9 17.0 1,2 18 x 20 5.5 x 6.1 4-12 102-305 36 136.2 20.2 1,4 18x22 5.5x6.7 4-12 102-305 40 151.4 25.0 1,7 Approval Type Quick Response Extended Coverage - Light Hazard Horizontal Sidewall. Minimum spacing between sprinklers - 8 feet (2.4m). Install below smooth, flat, horizontal ceilings only AS DEFINED BY NFPA 13. FACE OF F DEFLECTOR ORIENTATION 3/4--I4 NPd114 wmnrc ALUUSTMENY 4" TO 12" (IOI.B TO, 3048/AMT TOP OF DERECTOR PUSH ON/PULL OFF EMT CO✓ERP(ATE Sprinkler Identification Number (SIN) RA4762 _...-"'1 TION TAB NOTE DIMENSIONS IN BRACKETS ARE IN MM. 2. FRONT ✓IEN PUSH ON/PULL OFF COVERPLATE REMOVED Maintenance Model G6-80 Concealed Sprinklers should be inspected and maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other clean- ing fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler or cover plate assem- bly, which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinkler and cover plate assemblies should be maintained to allow quick re- placement of damaged or operated sprinklers. Prior to in- stallation, sprinklers should be maintained in their original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non -operation. Model G6-80 Concealed Quick Response Extended Coverage Light Hazard Horizontal Sidewall Sprinkler Specification Sprinklers shall be quick -response extended coverage sprinklers that are cULus Listed for use in Light Hazard oc- cupancies. Sprinklers to be of bronze frame construction with brass cover plate and copper alloy retainer flange as- sembly. Water seal assembly shall consist of a PTFE coated Belleville spring washer and machined brass cup contain- ing no plastic parts. Method of attaching the cover plate to the sprinkler cup shall be a push -on and pull -off design al- lowing a 1/4" cover plate adjustment. Sprinklers shall have a nominal K -factor of 8.0 (115 metric). Sprinkler temperature rating shall be 165°F (74°C) with a cover plate temperature rating of 135°F (57°C). Sprinklers shall be capable of a max- imum coverage area of 16 ft. x 24 ft. (4.9 m x 7.4 m) or 18 ft. x 22 ft (5.5 m x 6.7 m), with a minimum lateral spacing of 8 ft. (2.4 m). Rated working pressure shall be 175 psi (12,0 bar). A plastic protective cap shall be provided and fac- tory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Installation threads shall be [1 - inch NPT] [ISO 7-R3/4]. "Cover plate finish: [Chrome] [White] [Custom Color— specify]. Extended Coverage Concealed horizontal sidewail sprinklers shall be Reliable Model G6-80. SIN RA4762 (Bulletin 047). Ordering Information Specify: 1. Sprinkler: Model G6-80 2. Model G6 Cover Plate Finish Installation Wrench Model G6 Sprinkler Wrench Installation Aid A protective plastic cap is included for use during instal- lation. Cover Plate Finishesl'> p inishes plication Finishes Flat White Paint (1) Other colors and finishes are available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly ,ualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. `aIctured by ® Recycled Reliable Automatic Sprinkler Co., Inc. paper ® (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices EG. Printed in U.S.A. 08/19 P/N 9999970456 �� www.reliablesprinklencom Internet Address Rellabld Concealed Quick Response Sprinkler Coverage to20' x20' (6.0mx6.0m) Features 1. Quick response performance. 2. Push on, thread off, sturdy convenient cover plate. 3. Factory assembled sprinkler and cup, shipped complete with protective cap. 4. Sprinkler assembly and cover plate separately packaged. 6. Rugged damage resistant assembly. No exposed thermal element. 7. Utilizes the Model F1 FR QREC Pendent Sprinkler. 8. Aesthetic ceiling profile. 9. Standard finishes in white painted or chrome plated. Other color -painted and specialty finishes available. For Model F1 FR QREC CCP Ys" K 5.6 (80) Sprinkler Types refer to Bulletin 028 for technical specifications and approvals. Product Description Model F1 FR QREC Quick Response Extended Coverage Concealed Sprinkler is an attractive, low profile concealed sprinkler assembly This sprinkler assembly utilizes a Model F1 FR QREC pendent sprinkler in a Model CCP cup and push -on thread -off cover plate assembly The cup is securely factory threaded on the sprinkle's inlet end. The assembly is shipped with a protective cap. The sprinkler and cup are easily installed into the sprinkler fitting using the Model GFR2 Sprinkler Wrench. The cover plate assembly is attached to the sprinkler cup using a flexible tooth threaded engagement. The cover plate is attached to the skirt using 135°F (57°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the Bulletin 151 September 2029 Model 171 FR QREC CCP Concealed Quick Response Extended Coverage Sprinkler 0 cover plate melts, allowing the release of this part and thus exposing the Model F1 FR QREC sprinkler inside to the rising ambient temperature. The Temperature rating of the sprinkler identified by the color of the glass bulb. Model F1 FR QREC automatic sprinkler utilizes a 3.0 mm frangible glass bulb. This sprinkler has demonstrated response times in laboratory tests which are five times faster than standard response sprinklers. This quick response enables the Model F1 FR QREC sprinkler to apply water to a fire faster than standard sprinklers of the same temperature rating. Approval Type: Quick Response Extended Coverage — Light Hazard Technical Data: iQo F (3 "u) un y Note: 1 bar = 100 kPa The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 K Factor Sprinkler Approval (dent. LNicnalThread Size US Metric Organizations Number (SIN) 3/" (R3/e) 8.0 115.3 cULus R4842 Thread Temp. Rating Max. Size Model Ceiling Bulb Color Sprinkler Cover Temp. 3/" NPT FIFR 135°F 135°F 100°F (R3/) QREC 57°C 57°C 38°C Orange a/a" NPT FIFR 155°F 135°F 100°F (R 3/4) QREC 68°C 57°C 3g°C Red Coverage Area Pressure Flow Rate psi (bar) Max Enclosure Area gpm (L/m) Width x Length K=8.0 (Metric 115.3) ft x ft (m x m) 26 (98.4) 10.6 (0,7) 16 x 16 (4.9 x 4.9) 33(125.0) 17.0(1,2) 18x 18(5.5 x5.5) 40(151.4) 25.0(1,7) 20 x 20')(6.0 x 6.0)(1 iQo F (3 "u) un y Note: 1 bar = 100 kPa The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation Model F1 FR QREC Concealed Sprinklers use 135°F (57°C) or 155°F (68°C) Model F1 FR QREC Pendent Sprinklers with a threaded Model CCP cup which is factory attached to the sprinkler. The assembly is completed by the installation of the attractive, low profile, 135°F (57°C) rated cover plate assembly. The cover plate and sprinkler cup are joined using a flexible tooth threaded engagement. Do not install these sprinklers in ceilings which have positive pressure in the space above. The sprinkler cup is factory attached to the Model F1 FR QREC Sprinkler. A PTFE based thread sealant should be applied to the sprinkler threads only. After a Th inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model GFR2 Wrench. When installing a sprinkler, the protective cap is removed and the wrench is positioned into the sprinkler/cup assembly until the two wrench faces engage the wrenching flats on the Model F1 FR QREC Sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate assembly is then pressed into the cup. Final adjustment is made by turning the cover plate until the skirt flange makes full contact with the ceiling surface. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1 FR QREC Pendent Sprinkler or the use of the Madel CCP concealed cover plate assembly on any sprinkler with which it is not specifically listed may prevent good fire protection and will void all guarantees, warranties, listings and approvals. 1' , 3/4" REDUCING TEE OR E OM. A' 158 OIA- HOLE IN CEILMG - ---- T RA CO I}" [38.Imm] MAX FACE OF RMNG i0 FALE OF LERINL CEWNC GIVING'. � MAN }" [12Jmm] COVER AANSIMENr COVEF PU IE - pSSEMBLY�/[2� SPRINNL£R COVER PLATE, 1/2" [r2 ] 7 ADJUSTMENT I Maintenance Model F1 FR QREC Concealed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or nonoperation. Approvals cULus (Sprinklers, Automatic and Open. Quick Response Extended Coverage Sprinklers) NYC MEA 258-93-E Ordering Information Specify:Sprinkler Model: 1.F1FR QREC Pendent 3/4" NPT or ISO 7-R3/4 threads 2.Sprinkler Temp. Rating(': 135°F (57°C) or 155-F (68-C). 3.Cover plate Model: CCP 4.Cover plate temp. rating: 1351F (57'C). 5.Cover plate finish: hI 135°F (57°C) required for 20'x 20' (6.Om x 6.0m) coverage area Installation Wrench Model GFR2Sprinkler Wrench Installation Aid A protective cap is included for use during installation. Cover Plate Finishesm Chrome Bright Brass Black Plating Black Paint Off White (I) Other finishes and colors are available on special order. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. Important: The F1FR QREC Sprinkler with the Model CCP cover plate is not an FM Approved combination. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced bythe most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by ® Recycled The Reliable Automatic Sprinkler Co., Inc. Paper (800) 431-1588 Sales Offices Reliable ()848-6051 Sales Fax Revision lines indicate updated ornew data. (914914) 829-2042 Corporate Offices Pnu 99999/0148 www.reliablesPrinkler.com Internet Address Eo. Printed in U.S.A. os/zo Rel"iable Coverage to 18 ft. x 22 ft. (5.5m x 6.7m), 16 ft. x 24 ft. (4.9m x 7.3m). Features: 1. Flat cover plate. 2. K -factor of 8.0 (115 metric). 3. Listed as quick -response, extended coverage for Light Hazard occupancies. 4. Sprinkler assembly and cover plate packaged separately. 5. 1/4" (6.3mm) cover plate adjustment. 6. Model G6 Cover plate available in in a wide vari- ety of colors and finishes. Approval Organizations 1. Listed for use in Light Hazard occupancies by Underwriters Laboratories Inc. and UL certified for Canada (cULus). LIL Listing Category Sprinklers, Automatic and Open Quick Response Extended Coverage Sprinklers Product Description The Reliable Model 36-80 Concealed Quick Response Extended Coverage Horizontal Sidewall Sprinkler is an at- tractive, concealed sprinkler assembly that utilizes a push- on/pull-off cover plate assembly. The sprinkler assembly is shipped with a protective cap. The flat cover plate is attached to the skirt using 135°F (57°C) ordinary temperature classification solder. The sprin- kler is installed into the sprinkler fitting using the Model G6 Sprinkler Wrench. When the ambient temperature rises, the solder holding the cover plate melts, allowing the release of this part and thus exposing the sprinkler inside to the rising ambient tem- perature. The Model G6-80 utilizes a Quick Response soldered link. Quick -response sprinklers are designed to apply water to a fire sooner than standard -response sprinklers of the same temperature rating. The Model 36-80 sprinkler is listed for a maximum service pressure of 175 psi (12,0 bar). Reliable Automatic Sprinkler Co., Inc., 103 Bulletin 047 August 2019 Model G6-80 K8.0 (115 metric) Concealed Quick Response Extended Coverage Light Hazard Horizontal Sidewall Sprinkler (SIN RA4762) Application and Installation The Model 36-80 sprinkler is intended for installation in light hazard occupancies in accordance with NFPA 13. This sprinkler is especially well-suited for use in non -corrosive environments in student dormitories, hotels, hospitals and care facilities. Model G6-80 Concealed Horizontal Sidewall sprinklers utilize a sprinkler assembly with spring loaded deployable deflector feature. The assembly is completed by the instal- lation of the attractive, 135°F (57°C) push-on/pull-off cover plate assembly, which provides 1/4" (6.3mm) of adjustment. Apply a Teflon' - based thread sealant to the sprinkler threads. After a 2 s/e" (66.7mm) diameter hole is cut in the wall, the sprinkler is installed and properly oriented with the Model G6 Wrench, as follows: Do not remove factory installed plastic protective cap since it is sized to fit inside the G6 wrench. Note that the sprinkler can only mate when the sprinkler's deflector ori- entation tab (Fig. 1) is aligned with wrench's key -way. The G6 Wrench has a bubble level pad and TOP to assist the installer in properly orienting the sprinkler. Final leveling can be done after leak proof joint is obtained with a minimum to maximum torque of 14 to 20 ft -lbs (19 to 27 N m). Do not attempt to compensate for improper rough in dimensions of fitting by over tightening the sprinkler assembly, but readjust the sprinkler fitting instead. Leave the protective cap on to assure sprinkler protection while the wall is plastered, wall- papered or painted. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model G6-80 Horizontal Sidewall Sprinkler or the use of this dedicated concealed cover plate assembly on any sprinkler with which it is not specifically listed will void all guarantees, warranties, listings and approvals. DuPont Registered Trademark Fairview Park Drive, Elmsford, New York 10523 Technical Data: Nominal K -factor Thread Size Temperature Rating Maximum Ambient Maximum Water Working Pressure Sprinkler Identification Number us Metric Sprinkler Cover Umin psi bar 14x22 4.3x6.7 Temperature 102-152 (SIN) 8.0 115 3/a" NPT 1650F 135OF 1000F 175 P31 RA4762 132.5 19.1 or ISO 7-193/4 (74°C) (57°C) (38°C) (12 bar) 35 Coverage Area Max. Installed Coverage Area Width x Length Deflector to Ceiling Dimension Min. Required Flow Rate Min. Required Pressure ft. x ft. m x m inches mm gpm Umin psi bar 14x22 4.3x6.7 4-6 102-152 31 117.3 15.0 1,03 14x22 4.3x6.7 6-12 152-305 35 132.5 19.1 1,3 14x24 4.3x7.3 4-6 102-152 35 132.5 19.1 1,3 14 x 24 4.3 x 7.3 6-12 152 -305 39 147.6 1 23.8 1,6 16 x 16 4.9 x 4.9 4-12 102-305 26 98.4 1 10.6 0,7 16 x 18 4.9 x 5.5 4-12 102-305 29 109.8 13.1 0,9 16x20 4.9x6.1 4-12 102-305 32 121.1 16.0 1,1 16 x 22 4.9 x 6.7 4-12 102-305 36 136.2 20.2 1,4 16 x 24 4.9 x 7.3 4-12 102-305 39 147.6 23.8 1,6 18x18 5.5x5.5 4-12 102-305 33 124.9 17.0 1,2 18 x 20 5.5 x 6.1 4-12 102-305 36 136.2 20.2 1,4 18x22 5.5x6.7 4-12 102-305 40 151.4 25.0 1,7 Approval Type Quick Response Extended Coverage - Light Hazard Horizontal Sidewall. Minimum spacing between sprinklers - 8 feet (2.4m). Install below smooth, flat, horizontal ceilings only AS DEFINED BY NFPA 13. 2-3/8" tl/B MAXIMOM [60.3 ti2.m] FACE OF FITTING TO WALL DIMENSION DEFLECTOR ORIENTATION TAB CEILING DEFLECTOR ORIENTATION TAB 4" TD 12" [101.6 TO 3048((] TOP OF DEFLECTOR 0 B RECOMMENDED 3/8" R.. ® ® e WALL HOLE - __ - - __ _- [9511] 116- DAM EB 02 1 08 [66. MlA] PUS. ON PULL OFF FAT COVERPATE 3/4"-14 NP FRONT Vlf'N PUSH ON/PULL OFF COVERPAIE REMOUEO 3/16" 14 BUY] BUY]1/4 NOTE DIMENSIONS IN BRACKETS ARE IN IAM 614(1 AOJ 5/MEN figure 2. Maintenance Model G6-80 Concealed Sprinklers should be inspected and maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other clean- ing fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler or cover plate assem- bly, which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinkler and cover plate assemblies should be maintained to allow quick re- placement of damaged or operated sprinklers. Prior to in- stallation, sprinklers should be maintained in their original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non -operation. Model 136-80 Concealed Quick Response Extended Coverage Light Hazard Horizontal Sidewall Sprinkler Specification Sprinklers shall be quick -response extended coverage sprinklers that are cULus Listed for use in Light Hazard oc- cupancies. Sprinklers to be of bronze frame construction with brass cover plate and copper alloy retainer flange as- sembly. Water seal assembly shall consist of a PTFE coated Belleville spring washer and machined brass cup contain- ing no plastic parts. Method of attaching the cover plate to the sprinkler cup shall be a push -on and pull -off design al- lowing a 1/4" cover plate adjustment. Sprinklers shall have a nominal K -factor of 8.0 (115 metric). Sprinkler temperature rating shall be 165°F (74°C) with a cover plate temperature rating of 135T (57°C). Sprinklers shall be capable of a max- imum coverage area of 16 ft. x 24 ft. (4.9 m x 7.4 m) or 18 ft. x 22 ft (5.5 m x 6.7 m), with a minimum lateral spacing of 8 ft. (2.4 m). Rated working pressure shall be 175 psi (12,0 bar). A plastic protective cap shall be provided and fac- tory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Installation threads shall be [1 - inch NPT] [ISO 7-R3/4]. Cover plate finish: [Chrome] [White] [Custom Color— specify]. Extended Coverage Concealed horizontal sidewall sprinklers shall be Reliable Model 36-80. SIN RA4762 (Bulletin 047). Ordering Information Specify: 1. Sprinkler: Model 36-80 2. Model G6 Cover Plate Finish Installation Wrench Model G6 Sprinkler Wrench Installation Aid A protective plastic cap is included for use during instal- lation. Cover Plate Finishesttl Standard Finishes Chrome White Paint Special Application Finishes Bronze Black Paint Flat White Paint (1) Other colors and finishes are available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinklencom Internet Address ® Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 06/19 P/N 9999970456